Loading...
322 MAGNOLIA ST - REMODEL DRAWINGN PROJECT LOCATION 322 MAGNOLIA STREET ATLANTIC BEACH, FLORIDA 32233 16 -2S -29E SEC 2 SALTAIR LOT 292 BUILDING CODE DATA OWNER: Jennifer Chalot 322 Magnolia Street Atlantic Beach, Florida 32233 ADDRESS OF PROJECT: 322 Magnolia Street Atlantic Beach, Florida 32233 BUILDING CODES: 6th Edition (2017) of the Florida Building Code NFPA 70 - NEC 2014. 6th Edition (2017) of the Florida Fire Prevention Code COAB Code of Ordnances - OCCUPANCY CLASS: Single Family - Group R-3 DRAWINGS: Sheet 1 of 1 2'-6" # 4$-10" 01 NEW UNDER CABINET LIGHTING FIELD VERIFY SWITCHING EXISTING CABINETS TO REMAIN NEW RECESSED NORTH OUTLINE OF REMOVE AND REPLACE DIMMABLE EXISTING FIRST EXISTING CEILING CAN FLOOR AREA W/ i" DRYWALL LIGHTS REPLACE INSULATION IF (3) PRESENT HVAC COMPONENTS TO REMAIN NEW DIMMER SWITCHES REMOVE CEILING FAN -o v AREA OF WORK IN EXISTING HOUSE ROOM NEW PENDANT LIGHTS (4) DRAWINGS COMPLETED BY: Matthew Reimer Intracoastal Builders Corporation 8833 Perimeter Park Boulevard, #302 Jacksonville, Florida 32216 SCOPE OF WORK: Interior renovation consisting of the addition of non -load bearing walls, sliding barn doors, new countertop, and lighting reconfiguration. Removal and replacement of the ceiling in Room #1 to allow for lighting reconfiguration. No structural alterations or alternations to the building footprint will be made. No alterations to plumbing or mechanical systems. No exterior work. rrrfN- K: All electrical wiring to be in accordance with '08 NEC, Separate electrical permit to be obtained by Electrical Subcontractor. New lighting shall re -use existing lighting circuits in place. 1-011 e C-1 Intracoastal Builders Corp. 904.509.1345 intracoastalbuilders.com cry J RELOCATE(3) �� EXISTING m o RECEPTACLES O AND PROVIDE (1) NEW w RECEPTACLE Z AT NEW o COUNTERTOP C) O cD U AT 40" AFF W z W Cil FIELD LOCATEZD 771 WITH OWNER d- � W <C O W o n - W U 0 a EXISTING FLOOR TO BOTTOM OF EXISTING CEILING 2X4 SPF STUDS AT 16" O.C. O Z R 0 QM 2 (1) 2X4 SYP #2 PT BASE PLATE ( U (2) 2X4 SYP #2 DOUBLE TOP PLATE � Q ATTACH TOP PLATE TO INTERSECTING FLOOR TRUSSES W LL] Q75 REPLACE CEILING FAN X 3" SCREWS AT EACH LOCATION M U WITH NEW FLUSH 2-3/4" CSI U MOUNTED LIGHT FIXTURE NOTES: W N {-- (DIMMABLE) LAMINATE COUNTERTOP TO BE VENETIAN GOLD GRANITE 06223 -RD FORMICA OFFICE COPY �..E r 3. PENDANT LIGHTS TO BE LED DIMMABLE WITH 12" DOWNROD NEW 2'X6'-8" SLIDING BARN DOOR HARDWARE TO HAVE A BRUSHED NICKEL FINISH REVIEWED FOR CODE colwPUANc. CITY OF ATLANTIC BEACH W l DOORS (BARN DOORS) SEE PERMITS FOR ADDITIONAL < REQUIREMENTS AND CONDITIONS REVIEWED BY: DATE: �2 � O N EXISTING --� db OUTLET <C Z U y�614 2'-3111 4,_0,1 1'-11" 42111 i NEW NON -LOAD BEARING PARTITION WALL, EXISTING FLOOR TO BOTTOM OF EXISTING CEILING 2X4 SPF STUDS AT 16" O.C. (1) 2X4 SYP #2 PT BASE PLATE (2) 2X4 SYP #2 DOUBLE TOP PLATE 1/2" DRYWALL BOTH SIDES ATTACH TOP PLATE TO INTERSECTING FLOOR TRUSSES W/ (2) #8 X 3" SCREWS AT EACH LOCATION ATTACH BASE PLATE TO EXISTING FLOOR W/ (1)11 X 2-3/4" TAPCON AT 24" 0. C. NOTES: 1. LAMINATE COUNTERTOP TO BE VENETIAN GOLD GRANITE 06223 -RD FORMICA OFFICE COPY 2. CONTERTOP TO HAVE 45" BEVELED EDGE ON EXPOSED SIDES 3. PENDANT LIGHTS TO BE LED DIMMABLE WITH 12" DOWNROD 4. BARN DOOR HARDWARE TO HAVE A BRUSHED NICKEL FINISH REVIEWED FOR CODE colwPUANc. CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS REVIEWED BY: DATE: �2 REVISION, DATE, DESCRIPTION 0, 24JAN18, PERMIT ISSUE 1, 05FEB18, REVISED PERMIT ISSUE FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING WORK PROJECT NO.: 17052 1 SCALE: 1/2" = 1'-0" PROJECT PLANS DRAWING 1 OF 1