322 MAGNOLIA ST - REMODEL DRAWINGN
PROJECT LOCATION
322 MAGNOLIA STREET
ATLANTIC BEACH, FLORIDA 32233
16 -2S -29E SEC 2 SALTAIR LOT 292
BUILDING CODE DATA
OWNER:
Jennifer Chalot
322 Magnolia Street
Atlantic Beach, Florida 32233
ADDRESS OF PROJECT:
322 Magnolia Street
Atlantic Beach, Florida 32233
BUILDING CODES:
6th Edition (2017) of the Florida Building Code
NFPA 70 - NEC 2014.
6th Edition (2017) of the Florida Fire Prevention Code
COAB Code of Ordnances -
OCCUPANCY CLASS:
Single Family - Group R-3
DRAWINGS:
Sheet 1 of 1
2'-6" # 4$-10"
01 NEW UNDER CABINET LIGHTING
FIELD VERIFY SWITCHING
EXISTING CABINETS TO REMAIN NEW
RECESSED
NORTH OUTLINE OF REMOVE AND REPLACE DIMMABLE
EXISTING FIRST EXISTING CEILING CAN
FLOOR AREA W/ i" DRYWALL LIGHTS
REPLACE INSULATION IF (3)
PRESENT
HVAC COMPONENTS
TO REMAIN
NEW DIMMER SWITCHES REMOVE
CEILING FAN
-o
v
AREA OF WORK
IN EXISTING HOUSE ROOM
NEW PENDANT
LIGHTS (4)
DRAWINGS COMPLETED BY:
Matthew Reimer
Intracoastal Builders Corporation
8833 Perimeter Park Boulevard, #302
Jacksonville, Florida 32216
SCOPE OF WORK:
Interior renovation consisting of the addition of non -load bearing walls, sliding barn doors, new
countertop, and lighting reconfiguration. Removal and replacement of the ceiling in Room #1 to allow
for lighting reconfiguration. No structural alterations or alternations to the building footprint will be
made. No alterations to plumbing or mechanical systems. No exterior work.
rrrfN- K:
All electrical wiring to be in accordance with '08 NEC,
Separate electrical permit to be obtained by Electrical Subcontractor.
New lighting shall re -use existing lighting circuits in place.
1-011
e C-1
Intracoastal Builders Corp.
904.509.1345
intracoastalbuilders.com
cry
J
RELOCATE(3)
��
EXISTING m o
RECEPTACLES O
AND PROVIDE
(1) NEW w
RECEPTACLE Z
AT NEW o
COUNTERTOP C) O cD
U
AT 40" AFF W z W Cil
FIELD LOCATEZD 771
WITH OWNER d-
� W <C
O W o
n -
W U 0
a
EXISTING FLOOR TO BOTTOM OF EXISTING CEILING
2X4 SPF STUDS AT 16" O.C.
O Z
R 0 QM 2
(1) 2X4 SYP #2 PT BASE PLATE
( U
(2) 2X4 SYP #2 DOUBLE TOP PLATE
� Q
ATTACH TOP PLATE TO INTERSECTING FLOOR TRUSSES
W
LL] Q75
REPLACE CEILING FAN
X 3" SCREWS AT EACH LOCATION
M
U
WITH NEW FLUSH
2-3/4"
CSI U
MOUNTED LIGHT FIXTURE
NOTES:
W N {--
(DIMMABLE)
LAMINATE COUNTERTOP TO BE VENETIAN GOLD GRANITE 06223 -RD FORMICA OFFICE COPY
�..E
r
3.
PENDANT LIGHTS TO BE LED DIMMABLE WITH 12" DOWNROD
NEW 2'X6'-8" SLIDING
BARN DOOR HARDWARE TO HAVE A BRUSHED NICKEL FINISH
REVIEWED FOR CODE colwPUANc.
CITY OF ATLANTIC BEACH
W
l DOORS (BARN DOORS)
SEE PERMITS FOR ADDITIONAL
<
REQUIREMENTS AND CONDITIONS
REVIEWED BY: DATE: �2
�
O
N EXISTING
--�
db OUTLET
<C
Z
U
y�614
2'-3111 4,_0,1 1'-11"
42111
i
NEW NON -LOAD BEARING PARTITION WALL,
EXISTING FLOOR TO BOTTOM OF EXISTING CEILING
2X4 SPF STUDS AT 16" O.C.
(1) 2X4 SYP #2 PT BASE PLATE
(2) 2X4 SYP #2 DOUBLE TOP PLATE
1/2" DRYWALL BOTH SIDES
ATTACH TOP PLATE TO INTERSECTING FLOOR TRUSSES
W/ (2) #8
X 3" SCREWS AT EACH LOCATION
ATTACH BASE PLATE TO EXISTING FLOOR W/ (1)11 X
2-3/4"
TAPCON AT 24" 0. C.
NOTES:
1.
LAMINATE COUNTERTOP TO BE VENETIAN GOLD GRANITE 06223 -RD FORMICA OFFICE COPY
2.
CONTERTOP TO HAVE 45" BEVELED EDGE ON EXPOSED SIDES
3.
PENDANT LIGHTS TO BE LED DIMMABLE WITH 12" DOWNROD
4.
BARN DOOR HARDWARE TO HAVE A BRUSHED NICKEL FINISH
REVIEWED FOR CODE colwPUANc.
CITY OF ATLANTIC BEACH
SEE PERMITS FOR ADDITIONAL
REQUIREMENTS AND CONDITIONS
REVIEWED BY: DATE: �2
REVISION, DATE, DESCRIPTION
0, 24JAN18, PERMIT ISSUE
1, 05FEB18, REVISED PERMIT ISSUE
FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS
PRIOR TO STARTING WORK
PROJECT NO.: 17052 1
SCALE: 1/2" = 1'-0"
PROJECT PLANS