Loading...
195 Seminole Rd-Roof Non-Shingle CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 x�C it INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF18-0006 Description: METAL ROOF Estimated Value: 11000 Issue Date: 1/31/2018 Expiration Date: 7/30/2018 PROPERTY ADDRESS: Address: 195 SEMINOLE RD RE Number: 170604 0000 PROPERTY OWNER: Name: MICROBIAL NATURAL PRODUCTS INC Address: 1207 SEMINOLE RD ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: THE ROOF DUCK WATERTIGHT ROOFING SYSTEMS Address: 6095 Shadehill RD JACKSONVILLE, FL 32258 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. City of Atlantic Beach APPLICATION NUMBER J3 Building Department (To be assigned by the Building Department.) �(DO t 12) - 00C) � 800 Seminole Road Atlantic Beach, Florida 32233-5445 r Phone (904)247-5826 - Fax(904)247-5845 L�,tl9r E-mail: building-dept@coab.us Date routed: ' Z 1 S City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 C)S SSM I (00L-E7 �� Department review required Yes No _ Buildin Applicant: I-+c PODE L )vo_K Panning Zoning Tree Administrator Project: M, ETp' L_ Poop Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation r ` St. Johns River Water Management District V `/ Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: []Approved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONINGs Reviewed by: Date: � ZoA TREE ADMIN. Second Review: roved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES e PUBLIC SAFETY Reviewed by: Date: O cs FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 (904)247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 01/28/2018 Permit#: ROOF18-0006 Applicant: Alan Ross Site Address: 195 Seminole Road Address: 3948 3rd St,Jax Bch Review: 1 Phone: 904-345-0663 RE#: Email: Alan Ross <alan theroofduck.com> THIS BUILDING DEPARTMENT REVIEW IS ONE OF 1 DEPARTMENT REVIEWS. PLEASE FIND ALL DEPARTMENT REVIEWS AND ADDRESS ALL COMMENTS. Correction Comments: Application is disapproved for the following issues: 1. Attic ventilation is required, per FBC, Section R806. The upper roof ventilation appears to be adequate. Please submit details for the type and amount of attic ventilation for the lower roof, including each separate rafter space and the open attic area. Please include Florida product Approval and manufacturer's installation instructions for vents. Please submit two (2) copies of all documents. 2. Per NOA documents submitted, "FeltBuster' synthetic felt is listed under ASTM D 226,Type I. Type II is required, or two (2) layers of Type 1,per FBC,Table R905.1.1 (New Table for 2017). Per NOA documents submitted,FeltBuster is limited to thirty (30) days of direct exposure. Two layers are at least partially installed on this roof. Please verify that two (2) acceptable layers of FeltBuster are installed on entire roof. 3. Please submit the above corrections with a Revision Request Form. Dan Arlington darlington(a-,coab.us (904) 247-5813 1 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach, FL 32233 Office (904)247-5826 Fax(904)247-5845 Rd0; Job Address: 195 SEMINOLE ROAD Permit Number: 170604-0000 Legal Description 10-8 16-2S-29E.11 SALTAIR SEC 1 LOT 626 Parcel # 170604-0000 P'loor Area o q. t. Sq.Ft Valuation of Work-$ 11000 Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No N/A Florida Product Approval# 11651.19 For multiple products use product approval form Describe in detail the type of work to be performed: New Construction Metal Roof Property Owner Information: Name: Microbial Natural Products Address: 1207 SEMINOLE RD City Atlantic Beach State_Zip 32233 Phone 904-654-4244 E-Mail or Fax#(Optional) Contractor Information: Company Name: The Roof Duck Watertight Roofing Syst Qualifying Agent: _ _Gregory Alan Ross Jr Address: 3948 3rd Street South Unit 195 City Jacksonville Beach State EL Zip 32250 Office Phone 904-345-0663 Job Site/Contact Number 904-345-0663 Fax# State Certification/Registration# CCC1330963 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void f work is not commenced within six(6)months, or if consirtiction or work is suss ended or abandoned for a vriod ofsix/6)months at any time after work is commenced. I understand that separate permits must be secured for Electricar Work,Plumbing,Signs, W Tanks and Air Conditioners,etc ells,Pools,Furnaces,Boilers,Healers, WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby cert that I have read and examined thisplication and know the same to be true and correct. All provisions o a o nces governing this type o1 work will be complied with whether sppeci ed herein or not. The granting of a permit does not presume to a hority to v to or cancel the provisions of any other federal,state,or local lsw regulating construction or the.performanee of construction. Signature of Owner � ��-vim' Signature of Contractor Print Name IJI Print Name �G4 ...................... ..-..................................._....... .._........................................... ...... ..................... .............S.... ......................_.........__............_.. Sworn to and subscribed before me Sworn to and subscribed before me this Day of a M 201 'B this -i{-Day of --5cL h j-A,, LI .20 1 g Notary Public Notary Public or°o Notary Public State of Florida Notary Public Sta a of Florida Sharon P Smith gharon P Smittevtsed 01. 6.10 �,� My Commission FF 224917 • ' My Commission FF 224917 y., Expires 05/31/2019 arw Expires 05131/2019 - . «� CITY OF ATLANTIC BEACH r 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST Y CORRECTIONS TO PLAN REVIEW COMMENTS Date 1/29/2018 Revision to Issued Permit Corrections to Comments X Permit # ROOF 18-0006 Project Arldress 195.SEMI LADLE fk0AD Contractor/Contact Name THE ROOF DUCK WATERTIGHT ROOFING SYSTEMS Phone 904-345-0663 Email ALAN @THEROOFDUCK.COM Description,of Proposed Revision/Corrections: Permit Fee Due S 1. ADD HEADWALLL VENTILATION TO FIRST FLOOR�GULF COAST INSTALLATION MAN. PAGE 9 2. INSTALL TYPE II UNDERLAYMENT/ GATOR SKIN NOA 15-0707.09 Attic Calculations: I 000sqfl attic space using 1/150=480 sq.m.We are are using 601nft of Profile vent @ 17 sqm per lnft for a Iota of 1020 sa.in of net free vent area Additional Increase in Building Value$ Additional S.F. By signing bei � A-LAN`RGSS affcrrrt�the Revisionis inciusive ofthe proposed changes. (printed"name) 1/29/2018 Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Ouly) Approved ` Denied Not Applicable to Department Revision/Plan Review Comments rtment ReiAW. Planning &Zoning Reviewed By Tree Administrator Public Works Public Utilities O U Public Safety xDate Fire Ser*as- MIAMFOADE `� it MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTWE.OF ACCEPTANCE (NOA) www.miamidade.gov/economy Gardner Asphalt Corporation 4161 W.7°i Avenue Tampa,FL.33605 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.'The documentation submitted has been-reviewed and accepted by'Miami-Dade County RER-Product Control Section to be used in Miami made County and other areas where aiiowed'by the Aui iority Having Jurisdiction�AH3j. This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product oT materia wjAw thew.jprisd clow RER reserves the right to revoke thw acceptance,if it is, determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements ofthe applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Gardner Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: 'Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of dais NOFA shall-be considered.after a renewal:-application las been filed,and.there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. AD TIMMENT:The-NOA number preceded by the words Adiami�Dade County,Florida Mowed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,th 1t all be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 12-1120.05 and consists of pages'1 through 4. The submitted documentation:was reviewed by Alex Tigera. JAN 3 0 mg NOA: 15-0707.09 MIAMJAPPR COUNTY ExpiratlemDate: 03M19 Approval Date: 04/06/17 Page 1 of 4 RoomG 1.OMONENT APPROVAL. CateEory• Roofing Sub-Catep-ory: Underlayment Material: Asphalt 'RADE NA1V Es OF ftonVCTs MANUFACTUMD OR LABELED BY AP'1911t cAN'1 'Pest Product Product Dimensions Specification Description APOC Tuff-Felt 26 36"x 72'rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment,2 Manufacturing square#30. Location #1, 2 UnitedFGUR28 .36"x 72"-roUs ASTMD 226 T'ype'II Ashsit:SMwaWd Fek anent,2 Manufacturing square#30. Location #1, 2 APOC Tuff-Felt 46 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4 Manufacturing square#15. Location#1, 2 United FGURIO 36"x T44'roll's ASTM D 226 Type T Asphalt Saturated Felt underlayment, 4 Manufacturing square#15. Location #1, 2 United FGUR70 18"x 72'rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1 Manufacturing square#30. Location #1-2 GatwSkin 42"x 285.8' rolls ASTM D 226 Type II Synthetic roof underlayment comprised Manufacturing of layers of polyolefin film. Location #3 Weather-Armor CX-L 37.25"x 145'rolls ASTM D 226 Type II High strength hybrid underlayment Manufacturing co il'ised of two layers of polyolefin.and Location#3 polyester synthetic fabric with a thin layer of modified bitumen between the two plies. Weather-Armor SB-1 36"x 65' 8"rolls ASTM D 1970 Glass fiber reinforlymer modified Manufacturing asphalt,granulated o, M Location #4 underlayment. 0" NOA: 15-0707.09 MAMMAne C0j Expiration Date: 03/28/18 Approval Date: 04/06/17 Page 2 of 4 MANUFACTURING LQCAuoN8: 1. Tacoma,WA. 2. Eutaw,AL. 3. Hangzhou, China. 4. Springville,AL. EVmmcE Sumwrf'I o. Ttst A tney Ttst Identifier Test N mppte PRI Construction Materials GGI-100-02-01 ASTM D 226 06/22/12 Technologies GGI-101-02-01 ASTM D 226 06/22/12 GGI-132-02-01 ASTM D 226 04/28/15 GGI-176-02-01 ASTM D 226 09/26/16 :CGI-178-02-01 ASTM D 1970 10/25/16 INSTALLATION 1. Gardner Underlayments listed herein shall be installed in strict compliance with applicable Building Codes. 2. Gardner Underlayments listed herein shall be installed with a minimum 4-inch head lap and 6-inch side laps. 3. APOC-Tuff Felt 26,United FGUR20,APOC-Tuff Felt 46,United FGUR10,United FGUR70,GatorSkin,and Weather Armor CX-L shall be fastened with corrosion resistant tin-caps and approved roofing nails spaced 6 inches o.c.minimum at all laps and three staggered rows fastened at 172 inches o.c.minimum in the field of the roll.N&&-sWl be driven flush and 90 degrees.to the roof deck. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. BUI.LURNG PFERNUT RWIUMENTS. Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. od 44 )ow NOA: 13-0707.09 Mu►ME�we eourmr Expiration Date: 03/28/18 Approval Date: 04/06/17 Page 3 of 4 LimTAT[oNs:- 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3.. Weather.-Armor SB-1 shall not be trot mopped,- refer to manufacturer's published literature for product compatibility. 4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. Gardner Underlayments listed herein shall not be left exposed as a temporary roof for longer than 30 days of application. 6. APOC-Tuff Felt 26, United FGUR20, APOC-Tuff Felt 46, United FGUR10, and United FGUR70 may be used with Asphalt shingles, Wood shakes and shingles,Non-structural metal roofing, quarry slate,and as an anchorsheet the roof assemblies. I. �GatorSkin,-Wealber Armor CX4,, and Weather-Armor SB-1 may be used with. Asplialt shingles, Wood shakes and shingles,Non-structural metal roofing,and quarry slate. 8. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance. If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that apprvpi iaie decunx-ntaom is piovided to detarf compatibility of the products,wind uplift resistracc,,and fire testing results. 9. For fire classification of specific -roof assemblies .using Gardner Underlayments listen herein _refer to a current Approved Roofing Materials Directory for fire ratings of this product. 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE z? �o�: i�-o7o7.09 rtu►r�Noa�eeounmr Expiration Date: 03/28/18 Approval Date: 04/06/17 Page 4 of 4 01000 FLEXPRO LP2 RIDGE VE BETTER BEST Marco's newest innovation: a profile-cut stick or Our premier custom-cut vent strip includes roll product designed to fit most roof panels. PythonT" polyester vent material inserts for a snug fit and optimum ventilation at a cost • Won't absorb moisture,which can freeze and block lower than traditional fans and louvers. all ventilation • 2 beads of M63 Marco proprietary adhesive for superior hold • Custom-cut profiles for snug fit • Easy, one-person installation • Superior net-free ventilation reduces condensation • 40 year limited warranty FLE PiR • 2 beads of M63 Marco proprietary adhesive for superior hold • ASTM testing: D1929, D737 • Easy, one-person installation • Available in box or roll quantities • Moisture and pest barrier • 40 year limited warranty 2 Marco's new FlexPro offers a balanced combination of • Non-obtrusive appearance outstanding features from our superior LP2 and economical • Helps reduce utility costs Flex-O-Vent products. Made with Marco's unique polyester • ASTM testing: D1929, D737, D1294-86, D2261-83** fiber, FlexPro delivers durable, long-lasting performance. • Box quantity packaging Specs Our patented LP2 Ridge Vent is made from non-fabric- Net Free Area: FlexPro Panel Fit - 1-1/8" free-standing covered Python vent material.This durable, modified product, NFA 26 sq. in.* polyester is a non-woven, non-wicking, fiber-based matting. Available In:3' stick, 20' and 50' rolls Its specially cut contours provide a custom, low-profile fit for Air Permeability: >800 cubic feet per minute any pitch and most major metal roof profiles. LP2 provides Tear Strength: 3.5 ppi a superior net-free ventilation area that helps keep out Tensile Strength: 16 psi—Elongation 175% moisture, pests and dust. Plus, LP2 can be installed by just Compressive Strength: 1.8 psi at 75% one person in two easy steps. In fact,the screw bed and `Effective Net Free Area varies based on product height, industrial strength peel-and-stick adhesive pre-applied to panel profile,and installation methods. LP2 makes this one of the easiest installations imaginable. Specs** "tea Net-Free Area:Varies with profile based on7 square inches per linear foot of ventilation material Dimensions:Varies with profile Y Air Permeability:>760 cubic feet per ' to Cold Cracking: -25°F Tear Strength: Machine 25 pp i/Count p Compressive Strength: 1.8 psi at 75% Rain: No leakage � l I ` PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: 195 SEMINOLE Permit # Project Address: 195 SEMINOLE ROAD As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.tloridabuildin . riz. Category/Subcategory Manufacturer Product Description Limitation of Lse State# Local# A.EXTERIOR DOORS 1.Swinging 2.Sliding 3.Sectional 4.Roll up 5.Automatic 6.Other B.WINDOWS 1.Single hung 2.Horizontal slider 3.Casement 4.Double hung 5.Fixed 6.Awning 7.Pass-through ---- 8.Projected 9.Mullion 10.Wind breaker 11.Dual action �9 a 12.Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C.PANEL WALL 1.Siding 2.Soffits 3.EIFS 4.Storefronts 5.Curtain walls 6.Wall louvers 7.Glass block 8.Membrane 9.Greenhouse 10.Synthetic stucco ll.Other D.ROOFING PRODUCTS -1-AspM�itshingles Lki `7 K 2.UnderlaymentsROOFING 3.Roofing fasteners 4.Nonstructural metal roof GULF COAST SUPP PBR PANEL ROOFING 11651.19 5.Built-up roofing 6.Modified bitumen 7.Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing 11.Wood shingles/shakes 12.Roofing slate 13.Liquid applied roofing 14.Cement-adhesive coats 15.Roof tile adhesive 16.Spray applied polyurethane roof 2.Other Category/Subcategory Manufacturer Product Description imitation of Use State# Local# H.NEW EXTERIOR ENVELOPE PRODUCTS 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge.I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) & A74 u/k S S (Signature) Company Name: TFC— 2o4> r- D-I-C_l./, Mailing Address: 31 3 a 77'-e-'f- 5 City: A ll! ��C AJC State: (2 Zip Code: Z 2 Telephone Number:(00 O/y 7 Fax Number:( ) Cell Phone Number:( ) E-mail Address: MICROBIAL NATURAL PRODUCTS INC Primary Site Address Official Record Book/Page Tile 1207 SEMINOLE RD 195 SEMINOLE RD 17874-02482 9417 ATLANTIC BEACH, FL 32233 Atlantic Beach FL 32233 195 SEMINOLE RD Property Detail Value Summary RE# 170604-0000 2017 Certified 2018 In Prorens Tax District USD3 Value Method CAMA LAMA Property Use 0000 Vacant Res<20 Acres Total Building Value $0.00 ;0.00 #of Buildings 0 Extra Feature Value $0.00 $0.00 For full legal description see Land Value(Market) $170,000.00 $170,000.00 Legal Desc. Land&Legal section below Land Value(Agric.) $0.00 $0.00 Subdivision 03116 SALTAIR SEC 01 Just(Market)Value $170,000.00 $170,000.00 Total Area 4983 Assessed Value $117,274.00 $170,000.00 The sale of this property may result in higher property taxes.For more information go to Save Cap Diff/Portability Amt $52,726.00/$0.00 $0.00/$0.00 Our Homes and our Property Tax Estimator.'In Progress'property values,exemptions and Exemptions $0.00 See below other supporting information on this page are part of the working tax roll and are subject to change.Certified values listed in the Value Summary are those certified in October,but may Taxable Value $117,274.00 See below include any official changes made after certification Learn how the Property Appraiser's Office values property. Taxable Values and Exemptions—In Progress If there are no exemptions applicable to a taxing authority,the Taxable Value is the same as the Assessed Value listed above in the Value Summary box. County/Municipal Taxable Value SJRWMD/FIND Taxable Value School Taxable Value No applicable exemptions No applicable exemptions No applicable exemptions Extra Features No data found for this section 'P Land&Legal Land— Legal LN Code Use Description Zoning Front Depth Category Land Units Land Type Land Value I LN Legal Description 1 0100 RES LD 3-7 UNITS PER AC ARS-2 50.00 100.00 Common 1.00 Lot $170,000.00 1 10-8 16-2S-29E.11 2 SALTAIR SEC 1 3 LOT 626 .p Buildings No data found for this section Property Record Card(PRC) The PRC accessed below reflects property details and values at the time of Tax Roll Certification in October of the year listed. 2017 2016 2015 2014 •To obtain a historic Property Record Card (PRC)from the Property Appraiser's Office,submit your request here: More Information ontact Us I Parcel Tax Record GIS Map Map this property on Google Maps City Fees Record ii;✓ jj s , Gulfco t SUPPLY & MANUFACTURING C/ F4F FGQN�F�O �TsgNq C00 BF A�/q O Oi r C C f : q14. NS . or ' 3 0 EXPOSEDGULF ROOF Version 01-26-16 (See back cover)