Loading...
1475 Main - Fire Dept Denial Comments for 2.7.18 Revision to COMM17-0033 V4v L� CITY OF ATLANTIC BEACH FEB 7 2018 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST CORRECTIONS TO PLAN REVIEW COMMENTS Dm,W 1�7 418 Revision to Issued Permit— Corrections to Comments V/P1,mu#66MK-17-w*53 Project Address 14 -7 5- t-tAIW ST AIRANTLC, TWAC14t PL- -322--o Contractor/Contact Name 69rl-14 W-r"5 cz>�CnMdv IrVA"Ie- <2-Keml.4 Phone Email azkre I Obe'Q ya Cow% ree-K e3r(2-M Vn . C.0 Klk Description of Proposed Revision/Corrections: Permit Fee Due$ *,J .CO� F-%:V1zpJ0W 7-e�'wa<� ed'"t-etrktrsi EME KAgwg-c- 'wp isou-t=ut-le, 4011�47-XL7`11 Additional Increase in Building Value$ �4 Additional S.F. By signing below,I JAn-DIJ eAklk1f"4r, affirm the Revision is inclusive of the proposed changes. '-�?(printed natne) z� 06 /0-71t 6 Signora or/Agent(Contractor 71111 if increase in valuation) Date (Office Use Only) Approved Denied Q?�V— Not Applicable to Department Revision/Plan Review Coamments_ c )77�CAVN Department Review Required: Ved Planhing &Zonin Rev e y Tre!tm�lnlstrat�or Public Works Public Utilities --XAC Public-Sately ate Fire Plans Review Fire Prevention Division 214 N. Hogan Street, Room 281 Jacksonville, Florida.32202 February 26,2018 Metal Building Comm17-0033 1475 Main Street Atlantic Beach, Florida Please correct or provide the proceeding requested information to obtain plans approval.When resubmitting corrected sheets, please provide a written narrative letter responding to our comments and directing the plans reviewer to the sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER"WILL" RESULT IN A RETURNED FOR CORRECTIONS PERMIT STATUS. Revised sheets should be clouded clearly showing areas were changes or corrections have occurred and re-inserted with the original set of drawings with old sheets removed. Unbound plans will not be reviewed. If this is an electronic submission please make sure that written narrative is submitted under correspondence along with a "complete set" (not just the revised sheets) of electronic documents. Fire Department Access and Water Supply: Please provide the following information or provide approved City Development Number& 10 Set with plans. If a 10 set is not required our office still needs to confirm the following: FIRE DEPARTMENT ACCESS: NFPA 1, 18.2.3.2.1 A fire department access road shall extend to within 50ft (15m)of at least one exterior door that can be opened from the outside and that provides access to the interior of the building. When required by the authority having jurisdiction, road(s)or parking lots providing access to the main entrance door(s)shall be considered access roads and shall comply with the requirements of 18.2.3.4.1.1 and 18.2.3.4.1.2. DRIVING SURFACE: NFPA 1, 18.2.3.4.2 Surface. Fire department access roads shall be designed and maintained to support the imposed loads of fire apparatus and shall be provided with an all-weather driving surface. (JFRD Apparatus Average Weight is 32 Tons). DEAD ENDS: NFPA 1, 18.2.3.4.4 Dead Ends. Dead-end fire department access roads in excess of 150ft(46m) in length shall be provided with approved provisions for the apparatus to turn around. TURNING RADIUS: NFPA 1, 18.2.3.4.3 Turning Radius NFPA 1, 18.2.3.4.3.1 the turning radius of afire department access road shall be as approved by the AHJ. (JFRD Turning Radius is 46'.) NFPA 1, 18.2.3.4.3.2 Turns in fire department access roads shall maintain the minimum road width. Required Fire Flow: NFPA 118.4 and Table 18.4.5.1.2 Please Provide Fire Flow CalculationsAll"ormed Within The Last Year For the Nearest Fire Hydrant Located Within 500'Of The Most Remote Point Of The Proposed Building In Accordance With NFPA 1, Chapter 18"Fire Flow Requirements For Buildings" (2012 Sth Edition) NFPA 1, 18.4.1.1*The procedure determiningfire flow requirements for buildings hereafter constructed or moved shall be in accordance with Section 18.4.NFPA 1, 18.4.5.2 Buildings Other Than One-and Two-Family Dwellings.The minimum fire flow and flow duration for buildings other than one-and two-family dwellings shall be as specified in Table 18.4.5.1.2.