1380 CAMELIE ST - REVISION 2/22/18 t 01.114,- ,, rll,��, s FEB 2 2 2018 CITY OF ATLANTIC BEACH 800 Seminole Road '' ' Atlantic Beach,Florida 32233 75160:-.:V REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date -2-Z 2 '-1 D Revision to Issued Permit /Corrections to Comments Permit# Project Address 13 ,U ( iP /Ji 5.3 Contractor/Contact Name " 1 N.) 1/,-1 /L Phone 1 ill Z 3 C C,3d-7 . Email ' lv w►f►417,,.., •it t v - ' -.iv, I i Description of Proposed Revision/Corrections: Permit Fee Due 0.00 4 �v (iv1vu� 1vu�T/ )---7,44,e.)----' -7,44,L---- Additional Increase in Building Value $ _-4;1--- Additional S.F. - 4 By signing below,I r_61/ 11`-1 ne.--f jy\., affirm the Revision is inclusive of the proposed changes. (printed name) Signa 4Agent ntractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments LOA-i a e r rick- .gyp 3 66 cc27 4 1701 cam, Department Review Required: Bui n f an oning Reviewed By Tree Administrator Public Works Public Utilities 2/2 /20/8.-- Public Public Safety Date Fire Services OFFICE COP\ FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1538 Builder Name: Building Unlimited Street: 1380 Camelia St. Permit Office: City of Atlantic Beach City,State,Zip: Atlantic Beach, FL,32233 Permit Number: Owner: Building Unlimited Jurisdiction: 261100 Design Location: FL,Jacksonville County: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1767.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=13.0 1461.30 ft2 b.Frame-Wood,Adjacent R=13.0 306.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1538.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1277.00 ft2 6. Conditioned floor area above grade(ft2) 1538 b.Under Attic(Vented) R=19.0 261.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(160.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 232 a. U-Factor: Dbl,U=0.33 160.00 ft2 SHGC: SHGC=0.23 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 30.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 30.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 3.083 ft. Area Weighted Average SHGC: 0.230 14.Hot water systems 8. Floor Types (1538.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 1538.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 45.29 PASS Glass/Floor Area: 0.104 Total Baseline Loads: 45.21 I hereby certify that the plans and specifications covered by Review of the plans and :..0•-iHE STA, .••.. this calculation are in compliance with the Florida Energy specifications covered by this .;01'....................... Code. �q Digitally signed by Joshua calculation indicates compliance ;'UJ7i,, %• ,.••.., ""� Howard with the Florida Energy Code. ,,,�k°„ ,;�0 t PREPARED BY: Date:2018.02.21 11:19:48 Before construction is completed •` I€ - -,'cam: DATE: -05.00, this building will be inspected for �'t. ....-r...- compliance with Section 553.908 ° Florida Statutes. 1 ' '� I hereby certify that this building,a...designed,is in compliance ':.�{. 5 , with the Florida Energ o - 7 • COD '��•'' OWNER/AGENT.--2,... WNER/AGENT-- ---- BUILDING OFFICIAL: DATE: 1 0 -ZZ'1 DATE: fill(' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance with a selected proposed infiltration rate of 6.50 ACH50 requires an envelope leakage test report in accordance with R402.4.1.2.and an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1. 2/21/2018 11:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 ` FORM R405-2014 PROJECT Title: 1538 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1538 Lot# Owner Name: Building Unlimited Total Stories: 1 BlocWSubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Building Unlimited Rotate Angle: 270 Street: 1380 Camelia St. Permit Office: City of Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Design % 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 1538 13842 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1538 13842 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 181 ft 0 1538 ft2 ____ 0.4 0.3 0.3 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1666 ft2 0 ft2 Medium 0.4 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1538 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1277 ft2 0.23 Wood 2 Under Attic(Vented) Main 19 Blown 261 ft2 023 Wood 2/21/2018 11:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V # C)rnt To Wall Type Space R-Valup Ft In Ft In Area R-Valup Fraction Ahsnr C,raric°/ 1 N=>W Exterior Frame-Wood Main 13 11 10 8 117.3 ft2 0.23 0.4 0 2 N=>W Exterior Frame-Wood Main 13 24 9 216.0 ft2 0.23 0.4 0 3 E=>N Exterior Frame-Wood Main 13 40 9 360.0 ft2 0.23 0.4 0 4 S=>E Garage Frame-Wood Main 13 34 9 306.0 ft2 0.23 0.4 0 5 S--->E Exterior Frame-Wood Main 13 16 10 8 170.7 ft2 0.23 0.4 0 6 W=>S Exterior Frame-Wood Main 13 56 10 8 597.3 ft2 0.23 0.4 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>E Insulated Main None .46 3 6 8 20 ft2 2 S-->E Insulated Main None .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.33 0.23 40.0 ft2 8 ft 4 in 1 ft 0 in Drapes/blinds None 2 N=>W 2 Vinyl Low-E Double Yes 0.33 0.23 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 3 E=>N 3 Vinyl Low-E Double Yes 0.33 0.23 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 4 S=>E 5 Vinyl Low-E Double Yes 0.33 0.23 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 5 W=>S 6 Vinyl Low-E Double Yes 0.33 0.23 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 376.014 ft2 376.014 ft2 41 ft 9.4 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000372 1499.6 82.32 154.82 .2862 6.5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 30 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 30 kBtu/hr 900 cfm 0.75 1 sys#1 2/21/2018 11:18 AM EnergyGauget USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 ' FORM R405-2014 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply--- Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 232 ft2 Main 58 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr Ma [X]Jun Jul X]Au X]Se Oct Nov Dec Heatinf X' Jan X)Feb X Mar ' Ar I May [ ]Jun Jul l ]Augg l ]Sep Oct X Nov Dec Venting [ Jan Feb X Mar 7C Apr May [ ]Jun Jul [ ]Aug [ ]Sep `X Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/21/2018 11:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 ' FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1380 Camelia St., Atlantic Beach, FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=13.0 1461.30 ft2 b.Frame-Wood,Adjacent R=13.0 306.00 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1277.00 ft2 6. Conditioned floor area(ft2) 1538 b.Under Attic(Vented) R=19.0 261.00 ft2 7. Windows" Description Area c.N/A R= ft22 a. U-Factor: Dbl, U=0.33 160.00 ft2 11. Ducts R ft a.Sup:Attic, Ret:Main,AH:Main 6 232 SHGC: SHGC=0.23 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 30.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 30.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.083 ft. Area Weighted Average SHGC: 0.230 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1538.00 ft2EF:0.92 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building •.••�;/HE sr••••. Construction through the above energy s g features which will be installed (or exceeded) :/ ov ........."....'ATF• °••.: in this home before final inspection herwise� a new EPL Display Card will be completed yNJ;;;„°'��:•` _ ,,:,•. `•. based on installed Code •' -aures:" 7 I =i':�i�,,,-c•-- ;°,4'°,;o • Builder Signatui ---- - Date: c�.1: a /�, / J . ago / 0 � l Jl .r. ''{Y; •••••C•. Address of New Home: �J� C►3,,-,4/� 9� City/FL Zip: i .... f 3223 '••• °D *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/21/2018 11:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 ' FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 1380 Camelia St. Permit Number: Atlantic Beach, FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5) or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free" by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 2/21/2018 11:18 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O 8403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code, Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 2/21/2018 11:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3