1237 MAYPORT RD - BLDG COMMENTS 2/13/18 •
yr. City of Atlantic Beach iBuilding Department (To be APPLICATION NUMBER
,
signed by the Building Department.)
Z
fel'
800 Seminole Road
, Atlantic Beach, Florida 32233-5445 _.0 M f�/� —003
Phone(904)247-5826 • Fax(904)247-5845
t�013104 E-mail: building-dept@coab.us Date routed: I Z / I Z / (7
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 1 Z 37 rnq4,fb0--z Pent review required Yes No
Building(� i
Applicant: S pR iN3 Gly lL�. �V t L>DG—r�S lanninq &Zoninq
Tree Administrator
Project: c. kjG—,(ZI Q(L.. f2)0 t L, Cj 0 r Public Works
Public Utilities
Public Safety
ire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers ›a61
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco �a
Other:
APPLICATION STATUS
Reviewing Department First Review: ['Approved. I6Renied. ❑Not applicable
(Circle one.) Comments:
5 dr__ Co M�.._ T s
BUILDING 1
PLANNING &ZONING Reviewed by: ' ' Dg Date: 002--f'3 I.(Z.'7
TREE ADMIN. Second Review: A roved as revised.
❑ pp ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
S w-7„,
,„ 1,...a„` „�
% v CITY OF ATLANTIC BEACH
1 r^) 800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
(904)247-5800
\Ji31 c-)r
BUILDING DEPARTMENT REVIEW COMMENTS
Date: 2/12/18
Permit#: Comm17-0032 Applicant: Springhill Builders
Site Address: 1237 Mayport Rd. Address: 13398 US 90
Review: 1 Phone: 386-401-9363
RE#: Email: tim@thebuildingbutlors.com
THIS BUILDING DEPARTMENT REVIEW IS ONE OF 3 DEPARTMENT REVIEWS.
PLEASE FIND ALL DEPARTMENT REVIEWS AND ADDRESS ALL COMMENTS.
Correction Comments:
Application is disapproved for the following issues:
1. Please complete all lines of permit application. All printing on form must be legible and readable.
Workers Compensation: owners of company can be exempt. All other workers on job site must be covered
be Workers Compensation. Please submit all proof of Workers Compensation and exemptions.
2. Valuation of Work: all work,materials, equipment, and systems are included in Valuation. Please submit
entire Valuation.
3. Please provide copies of the license and permit applications for the applicable State agencies regulating this
business; Division of Hotels and Restaurants, Department of Agriculture, and/or other.
4. The area around the toilet rooms is considered a food preparation area. Per FBC-P, Section 403.3.2,toilet
rooms cannot open directly into a food preparation area.
5. Please provide a service sink, per FBC-P, Table 403.1.
6. Please clarify if water heater is classified as a boiler, per FBC-M, Chapter 10 and provide all details.
7. Please show work space, on plans, in front of electrical panels,required by NEC, 110.26.
8. Multiple new heat-producing units are shown on plans. Please submit energy sheets, per FBC-EC,
Section C-103.
9. Please see Fire Marshal's comments, dated 1/4/2018. Where there is a conflict between comments from
different agencies, the strictest will apply.
10. New submittals may generate additional comments.
Dan Arlington, CBO
(904) 247-5813
darlington@coab.us