1799 ATLANTIC BEACH DR - FORM BOARD ELEV FORM BOARD ELEVATION CERTIFICATE
Date / . - 20 / 7 Permit Number: o23 z
Address: / 7 2 9 . /c ii-7t c /11e‘--c-4 DiZ
All American Surveyors Work Order # /C0,3 s"2
Required Slab Elevation on City Approved Site Plan:
Actual Elevation of Form Board or Grade Stake:
Survey Company:
ALL AMERICAN SURVEYORS OF FLORIDA INC.
3751 San Jose Place, Suite 15
Jacksonville FL 32257 Work Phone: 904-279-0088
Signature of Surveyor: (PartyChief)
M.,.
UNIVERSAL UES Project No: 0910.1400187.0000
11-r Workorder No: 197476-1
ENGINEERING SCIENCES Report Date: 1/31/2018
Consultants In:Geotechnical Engineering•Environmental Sciences
Geophysical Services•Construction Materials Testing•Threshold Inspection
Building Inspection•Plan Review•Building Code Administration
5561 Florida Mining Blvd So.,Jacksonville, 32257 • P: 904-296-0757 • F: 904-296-0748
In-Place Density Test Report
Client: UES Technician: Kevin Gagnon
160 Cape May Avenue
Ponte Vedra, FL 32081 Date Tested: 01/31/2018
Project: 1799 Atlantic Beach Dr, Atlantic Beach Country Club
Area Tested: lot 41 Type of Test:
Material: Fill Field: ASTM D-2937 Drive Cylinder Method
Reference Datum: 0 = Top of Fill Laboratory: ASTM D1557 Modified Proctor
The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density.
Fill
Maximum Optimum Field Dry Field Soil Depth Test Density Moisture Density Moisture Compaction p Pass
No. Location of Test Range (pcf) (%1 (pcf) (%1 (%1 (inch) or Fail
1 11' N 18' E of SW corner 0-1 ft 103.3 14.3 99.1 8.5 96 N/A Pas:
2 12' N 21'W of SE corner 0-1 ft 103.3 14.3 100.1 7.5 97 N/A Pas:
3 13' S 18'W of NE corner 0-1 ft 103.3 14.3 103.3 8.1 100 N/A Pas.
4 3' S 18' E of NW corner 0-1 ft 103.3 14.3 99.7 7.7 97 N/A Pas:
To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and authorization