303 ATLANTIC BLVD - ROOF Is1 CITY OF ATLANTIC BEACH 5v 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 r;; c..)% INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF18-0007 Description: FLAT ROOF Estimated Value: 69037 Issue Date: 1/29/2018 Expiration Date: 7/28/2018 PROPERTY ADDRESS: Address: 303 ATLANTIC BLVD RE Number: 169729 0000 PROPERTY OWNER: Name: JUNKSHIRLEY Address: 915 13TH ST N JACKSONVILLE BEACH, FL 32250-3653 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: Energy Roofing Technology SE, LLC Address: 10153 W US HWY 90 LAKE CITY, FL 32055 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. el City of Atlantic Beach APPLICATION NUMBER Js Building Department (To be assigned by the Building Department.) ilk, � RoorIB - 0o© Al 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 / �f / E-mail: building-dept@coab.us Date routed: / Z 4 / 1 City web-site: http://www.coab.us l APPLICATION REVIEW AND TRACKING FORM Property Address: 303 tiz v--t( 61...)/ Department review required Yes No Building E Applicant: l� me:R� ROQ Ft &Zoning Tree Administrator Project: rt—Pc-Z C)op-- Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 'LI pproved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING118 Reviewed by: Date:O I TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 CITY OF ATLANTIC BEACH at 800 SEMINOLE ROAD '4I15P' ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 241-5814 COMMERCIAL-ADDITION COMMERCIAL MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: 17-CADD-3210 Description: Estimated Value: 1300000 Issue Date: 5/3/2017 Expiration Date: 10/30/2017 PROPERTY ADDRESS: Address: 303 ATLANTIC BLVD RE Number: 169729 0000 PROPERTY OWNER: Name: Address: GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: Address: Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON TILE J O B SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. *A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work,a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. Scanned by CamScanner .451, • Building Permit Application Updated 12/8/17 City of Atlantic Beach 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 t 0 )F 18 - 0007 Job Address: 303 Atlantic Boulevard, Atlantic Beach, FL 32233 Permit Number: 17-CADD-3210 Legal Description 05-069 21 2S-29E RE# Valuation of Work(Replacement Cost)$69.037.00 Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle one): New A. dditio Alteration '-p.ir Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): ommercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one)(Ye's")No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: n ? Oo F Florida Product Approval# FI 16039-R11 for multiple products use product approval form Property Owner Information Name: Shirley Junk Address: 915 13th Street North City Jacksonville Beach State FL Zip 32250 Phone E-Mail Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Contractor Information Name of Company: Ener�1y Roofing Qualifying Agent: Barry Joye Address 10153 W US Flwy 90 City Lake City State FL Zip 32055 Office Phone (855) 766 3852 3��1� Job Site/Contact Number (3R6) R67-4756 State Certification/Registration# P9-5u11 E-Mail bdjoye@earthlink.net Architect Name&Phone# Engineer's Name&Phone# Workers Compensation 7J WC PLZ(O 2(1 4,W/ L rp.e" S 05)(1%/9.0/5 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BE ORE RECORDING YOUR NOTICE OF COMMENCEMENT. \/(1-Q_ c? 1 (Signature of Owner or Agent) (Signature of C'ntract ) (including contractor) Signed and sworn to(or affirmed)before me this R4filday of VAKdl4rrj�igned and ' orn to(or affirm d)befor me this 21ay of hVQ� , al7\% ,by e mQ.11SUc .( re) ,by it'(J JO QJ te(2nmAii_. LIP J J (Signature of Notary) ,,(5igpa*woof Notary) // LESLIEANN PIAZZA [ Personally Known OR Personal) Known OR ;'; �i+:.'''% ELAINE M.SILVER ( y ': MY COMMISSION t GG090388 [ ]Produced Identification = ''� '..,: MY COMMISSION#GG 072501 ( ]Produced Identification --7,170t7.:4: EXPIRES April 04,2021 •Type of Identification: Type e of Identification: e =d. EVIRES:February 13,2021 yp 'or° Bonded Thal Nobly Pubic Undwwf I1 NOTICE OF COMMENCEMENT (PREPARE IN OUPUCATE) J Q Permit No- Tax Folio No. D State or FLORIDA Courtly of DUVAL r( o sn a To whom It may concern: a O me undersigned hereby informs you that Improvements will be made to certain real property,and In F • with Section 713 of the Florida Statutes,the following Information Is stated Wilts NOTICE OF m U COMMENCEMENT. Y o v Legal desaipfwn of propeity being improved:05-069 21 2S-29E re r� g ATLANTIC BEACH LOTS 2,4,6 BLK 1 (v 'e,, d OM 8K 6610-1725 8-_" w 303 ATLANTIC BLVD F: q^g o Address of property being : R:n o ;}o ATLANTIC BEACH,FL 32233 ` v 1 z RESTAURANT RENOVATION N d inprrSvemen xu § g5,32� �j� Caenerel desalption ts: 8 7 � o o w clZtYecUct SAL MANSUR Address 240 N THIRD ST NEPTUNE BEACH,FL 32250 Owner's interest in site of the i-r xovement LEASE HOLD Fee Simple Talehoider of other than owner) SHIRLEY JUNK Name SHIRLEY JUNK Address 915 13TH ST N JACKSONVILLE BEACH,FL 32250 a4' Contractor RIVERCITY CONTRACTORS CI Address 1510 MONTANA AVE JACKSONVILLE,FL 32207 (1 Phone No.got-399-6846 Fax No.904-399'8896 ��VV Suretyi1 any) ( Y Address Amount of bond 3 Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name T17 I '4M Address 9iic ,M7 �/�/ p� , ,0 4 /v/G4f �G 7;;,zw, Phone No. 9dy .26‹ /163 Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: /� Name ,4 Mi9�- "142 Address *4' Arle9NT/G , G1/17'. RtrMNT/G Jf fG 374234 Phone No. g!/7 63? 616'9 Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b).Florida Statutes_(Fill in at Owner's option). Name /'9/GH/9E1-- JG/VR Address ?/r //Oa.71 17A. ,,j Xe ' Y/GI. P 41 JS;FL . ..24_, Phone No. 9V y ,Zts7 G7/'f Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OVIN Signed de,DATE 111x111.2 a Wont ma Ihla \r dq of ••„, k „M Can of Duval. , <<Sudo of U K hal pommy sweated ��y � . imilliMb ( f`'^ ) .++, himsate Mysa. lf and``atIkms VA Ml slalerrards and decrnda s Mntn A081N K.BARNES are true and manta i ' Nourypublic- uteof Florida :, CommissbntFF82481 '.. c , l •.? k ' MyComm.ExpinsJan 22.2018 — �•AI♦ Notary Pubic at Lew Stated t?+. . .Cady orM.-___4!..."_..A. My carmdulm WIN: a Pereonsay Krw•in Produced WaMlicMbn Scanned by CamScanner ZA\IL. 10153 West Highway 90. Lake City. Fl 32055 • 386-867-4757 WWW COM ENERGY ROOFING FLORIDA F'R COD CH D BEA REVlECl� OF A S�pR:001110140- January p1S1O.�ONS January 17, 2017 gEE pERM1Y ANP GO t5 0� 2 tp REQUIRE". o : � c--'—" Roof Proposal: Coop 303, Atlantic Beach, FL. ,rrWED gY: WE HAVE INCLUDED: • PROVIDE AND INSTALL 4" BASE LAYER OF ISO. • PROVIDE AND INSTALL A COMPLETE ISO TAPER PACKAGE WITH A 1/8" PER FOOT SLOPE, MECHANICALLY ATTACHED AND CRICKETS TO DIRECT THE WATER TO THE SCUPPERS. THE 4" BASE LAYER ALONG WITH THE TAPER PACKAGE ACHIEVES THE AVERAGE R-38 VALUE GIVEN TO US AS THE TARGET R-VALUE. • PROVIDE AND INSTALL A COMPLETE DURO-LAST 50MIL PVC ROOFING SYSTEM USING THE DURO- TUFF PRODUCT LINE, MECHANICALLY ATTACHED DECK MEMBRANE AND FULLY ADHERED PARAPETS. THE SYSTEM INCLUDES CURBS, STACKS, SCUPPERS, LEADER HEAD AND DOWNSPOUTS. PARAPETS WILL BE FINISHED 12"ABOVE THE DECK, BACK SEALED AND THE STUCCO WILL COME DOWN OVER IT. WARRANTY: • ENERGY ROOFING TECHNOLOGY INSTALLATION AND WATER TIGHT AND CRAFTMANSHIP WARRANTEE 3 YEARS • DURO-LAST 15YR. NDL, ONCE INSPECTED BY A DURO-LAST TECHNICIAN AND APPROVED. PRICE: • $69,037.00 NOTE: Price is based on the following assumption: 1. A 4"base of ISO with an 1/8"taper package on top will meet the R38 requirements. Numbers must be verified by ISO suppliers. 2. Ten over-flow scuppers will be required. We accept this proposal, approve ordering the material and setting an immediate start date. Signed. Date: Uf< �l /A Ofr�i Authorized Representative River City Contractors Signed:a O Date: O(^ (7 ' 2.0/4p �O Authorized'epresentative Energ Roofing Technology, SE Ay PAGE 1 OF 1 "(f.15 -."- IDUROa LAST. , SCE 7- 10 WIND CALCULATIONS FOR ROOFS, Project Number: 80838-2 Job Name: Coop 303 Contractor: Energy Roofing Address: 303 Atlantic Blvd Address: City: Atlantic Beach State: FL City: State: Section: Fax/E-Mail: eric.s@energyroofingco.com Roof Dimensions(ft): 50 x 136 Enclosed Building Height(ft): 26 If estimated,verify and Exposure C Min.Parapet Wall Height(in): 36+ sign for these talcs to be Risk Category II Deck Type: Metal permitted Basic Wind Speed(mph): 129 Avg. Pullout Resistance(lbs): 500 X-Contractor Estimated Enhanced Perimeter Width(ft): 5.00 Fastener Type: # 5 Screw Perimeter enhancement is figured using either 40%of the Tab Spacings: 1. 56 2. 56 3. 56 building height or 10%of the shortest overall building Insulation Board Size: 4 x 4 Fstnrs/Bd: 4 dimension,whichever is less.Minimum value is 5-0' Strength Design: ASD Membrane Enhancement Per RAS 137 x New Construction Basic Velocity Pressure: Insulation Attachment Per RAS I 17 x Constant Kz Kzt Kd V2az 0.00256 Velocity Pressure Wind Speed Wind Directionality Basic Wind Speed- = Lbs/SqFt Coefficient Coefficient Factor Squared 0.00256 0.953 1 0.85 16641.00 34.51 Zone 1 Attachment . Membrane Fastening ab Spacing (ft): 4.67 Fastener Spacing OC(in): 12 SqFt/Fstnr: 4.67 Insulation Fastening Board SqFt: 16 Fasteners Per Board: 4 SqFt/Fstnr: 4.00 Zone Coefficient: -0.71 System Type: Mechanically Attached-3"Tabs 'one Velocity Pressure: -24.43 Attachment: 56"Laps Fastened 12"On Center Safety Pressure: 60.00 Fasteners: Poly Plates-#15 Fasteners Design Pressure: 96.43 Insulation Attachment 4x4 Board fastened at 4 Fasteners/board Notes: DL s•ec which exceeds FBC 1:6.4 SF re•uires Fastener Densi of 1:4 SF 4 Zone 2Attachment - -44111P- leo Membrane Fastening ab Spacing(ft): 4.67 Fastener Spacing OC(in): 12 SqFt/Fstnr: 4.67 Insulation Fastening Board SqFt: 16 Fasteners Per Board: 4 SqFt/Fstnr: 4.00 Zone Coefficient: d., ; op,-System-Type:- MechanicallyAttached-3"Tabs :one Velocity Pressure: -41.00 attachment: 56"Laps Fastened 12"On Center _ a ety ressure: 82.00 Ii+Fasteners: Poly Plates-#15 Fasteners Design Pressure: 96.43 ■Lb•datiay.Attachment 4x4 Board fastened at 4 Fasteners/board Notes: DL s•ec which exceeds FBC 1:6.4 SF re•uires Fastener Densi of 1:4 SF Zone 3Attachment. 'em.rane as ening a. pacing . : 4.67 as ener pacing • in : 12 q 7 stnr: 4.67 Insulation Fastening Board SqFt: 16 Fasteners Per Board: 4 SqFt/Fstnr: 4.00 Zone Coefficient: -1.19 System Type: Mechanically Attached-3"Tabs _ :one Velocity Pressure: -41.00 Attachment: 56"Laps Fastened 12"On Center Safety Pressure: 82.00 Fasteners: Poly Plates-#15 Fasteners Design Pressure: 96.43 Insulation Attachment 4x4 Board fastened at 4 Fasteners/board Notes: DL spec which exceeds FBC (1:6.4 SF) requires Fastener Density of 1:4 SF 3 ZONES Compliant With: NOA# 17-0202.09-Sys D(8) 2 1 2 System Design Pressure(-PSF): -45 Lbs per SqFt(PSF) Lap Spacing: 56 Fastener Spacing: 1 Z Notes: o� 3 z 3 No Wind Tab Required v 16 cF 3 . I oo These calculations have been done in accordance with ASCE 7(05 or 10) DO NOT ORDER UNTIL BUILDING skit(dards.However,ti tee celculdtior IS du;105(eke precede;ice over local building codes.All calculations on this report are based on information PERMIT IS OBTAINED provided by the contractor.Calculations can not be relied upon should Done By: Osmond Urivez any of the provided information prove to be inaccurate. 1/25/20185:20 PM Date: 1/25/2018 Engineer Stamp(if required) 17, Membrane Type: Single Ply,PVC Deck Type 2I: Steel Deck,Insulated Deck Description: Minimum 22 ga. Grade 33 steel deck is secured to steel deck supports spaced maximum 6 ft. o.c. with TRAXX/5 fasteners installed 6 in. on center. Side laps secured with Traxx/1 fasteners at 24 in. o.c. This Tested Assembly has been analyzed for allowable deck stress. See evidence submitted table. System Type D(8): Membrane fastened over preliminarily fastened insulation. All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply.Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Base Insulation Layer(Optional) Insulation Fasteners Fastener (Table 3) Density/ft2 Any Approved EPS or XPS listed in Table 2 Minimum IA"thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Duro-Guard Iso II-A,Duro-Guard Iso II-H,Duro-Guard III-A,Duro-Guard Iso III-H,ENRGY 3, H-Shield,ISO 95+GL,ACFoam H,ACFoam III,Duro-Guard Iso II-G Minimum 1%"thick 1,2,3,10 1:6.4 ft2 ACFoam IV Minimum 2"thick 1,2,3,10 1:6.4 ft2 Note: Insulation layers above shall be mechanically attached with preliminary fastening as specified above.All Insulation panels shall also be mechanically fastened along with the roof membrane as specified below. See Roofing Application Standard RAS 117 for fastening details. Membrane: Minimum 50-mil Duro-Tuff membrane shall be mechanically attached 12"o.c. in rows spaced 56"o.c with Duro-Last Cleat Plates and Duro-Last#15 Extra Heavy Duty Drill Point Fastener. Laps are sealed with minimum 1.5"wide heat weld. Maximum Design Pressure: -45 psf. (See General Limitation#7) O^ O,o NOA No.: 17-0202.09 MIAMI•DADE COUNTY Expiration Date: 08/22/22 APPROVED Approval Date: 08/31/17 Page 48 of 63 % 1s>68ft. Figaro 6-17 External Pressure Coefficients,GCp Enclosed,Partially Eadaeed BadMinge Walls & Roofs €1,_,_,..413....._L.„0 ' ,'ja 10 20 500 1 r ,1.t g ' 4.4 42 p ©, O © 40I Illino .32 ,u I I II J L i'� x.4 .0loll -22 4 ©~ © _ © 5 -2.011ROOF PLAN .,: ■ MN ,e T .12 1111111 � r '1.0 4.0 O liTillin......_% 1 •t.o -as� 1! -0A ' r -C11 d.7 I I -0A 11 r i r4.2 O r , -T— r r 40.4 0 1111 Ai CS) © Q _ w40.0 ' +tA +a.1 1 10 20 50 100 200 500 1000 i i {0.1) 1S1 (1S) Ng) (3)(184) 144 OM ' Effective Wind Ames,ft2(m2) r , 1 t WALL ELEVATION Notes: 1. Vertical scale denotes GC,to be used with appropriate q,or q4. 2. Horizontal scale denotes effective wind area.,in square feet(square meters). 3. Plus and minus signs signify pressures acting toward and away from the surfaces,respectively. 4. Use q,with positive values of GC,and qua with negative values of GC,. 5. Each component shall be designed for maximum positive and negative pressures. 6. Coefficients are for roofs with angle 8 S 10°. For other roof angles and geometry,use GC, aSi ei from Fig.6.11 and attendant q„based on exposure defined in 6.54. V�� 7. If a parapet equal to or higher than 3 ft(0.9m)is provided around the perimeter of the roof with 84//q_ 10°,Zone 3 shall be treated as Zone 2. (�^vo 8. Notation: PI a: 10 percent of least horizontal dimension,but not less than 3 ft(0.9 m). �� h: Mean roof height,in feet(meters),except that cave height shall be used for 8 S 10°. z: height above ground,in fleet(meters). 0: Angle of plane of roof from horizontal,in degrees. Minimum Design Loads for Bdldkrps and 011ier Structures as ' ,Ce.,— 7 --k- � _No e,,.. rbc it.tc5 Tac o>z 4sCa 7 ee*-i ( DETAIL 1020 DUR0 LAST. AIi THE WORLD'S BEST ROOF 4x8ft 4x4ft Approved Insulation Approved Insulation V v v O 0 0 0 0 0 0 O O 0 O 0 0 O 0 00 0 0 O 0 O O 6" 6" 0 0 O O O O O 0 O O o 6" Fnuil— 6" -ow' 1-.1.- 2x4ft 4x8ft Approved Insulation Approved Cover Board O 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0. 0 0 0 0 0 0 0 6" O 0 0 0 [ 6" 0 O O 0 0 0 0 a T 12" --m- H6" h"1.--- Note 1: It is recommended to stagger all joints between boards by 50% from row to row and layer to layer. Note 2: Adjoin panel edges together. Neatly fit to the roof deck and arouetrations with no gaps greater than 1/4 inch. le Note 3: Fasten with approved plates and fasteners. %� Note 4: These fastening patterns are to be used with mechanically fastened D4 systems only. rREVISED: 01/30/2017 GENERAL DETAIL FOR MECHANICALLY FASTENED SYSTEMS PREVIOUS: 01/01/2009 INSULATION AND RECOVER FASTENING `SCALE: NONE NEW CONSTRUCTION OR RE-ROOF 1 • DETAIL RG1052 DLJROLASTl W MA THE WORLD'S BEST ROOF Wall height moless than 2 feet OA o�� • 60-- foil rbo� �o� moi • vo oO Q- � s 401lAopOol -y • Wall height 2 feet, or taller © 60� 627, moi <Zs)� 'poi o b2a 0 • 164! • 4000 Note 1 : Contact the Duro-Last® Engineering Services Department for assistance in determining the fastening requirements if: the building is 40 feet tall, or taller; or the building is located in an area with an ASCE 7-05 design wind speed,of 110 mph, or higher (150 mph, or higher, for ASCE 7-10); or fastener pullout resistance is less than 150 lb. �� Note 2: Refer to RG1062 and RG1064 for fastener placement and sheet overlap. �O^ Note 3: 120-inch fastener row spacing is not acceptable within 7 feet of any perimeter edge. REVISED: 02/03/2017 GENERAL DETAIL FOR ROLL GOOD MECHANICALLY FASTENED SYSTEMS PREVIOUS: 04/03/2014 PERIMETER FASTENING WITH 120, 60 AND 30-INCH WIDE ROLLS SCALE: NONE NEW CONSTRUCTION OR RE-ROOF di TECHNICAL SERVICES, LLC Duro-Last Roofing, Inc. CREEK PVC Single-Ply Roofing Membranes APPENDIX B Mechanically Fastened Recover Assemblies System Existing Roof Insulation Insulation Membrane Membrane Attachment MDP No. Attachment (psf) Duro-Last Auger Fasteners(min.2.5-inch penetration into substrate)and Auger Plates or R-M-3 Poured Gypsum DT or DL TRUFAST Twin Loc Coiled Batten Bar and TRUFAST Twin Loo- Nail Batten Fastener fastened through the membrane ® .7) 6-inch o.c.in rows spaced 48-inch o.c.; 10-inch wide cover stet welded over fastener rows with 1.5-inch wide heat wel stet) Duro-Last#15 Extra Heavy Duty Drill Point Fastener R-M-4 Steel Deck - o.c.w - DT Cleat Plates fastened 12-inch within -45(G33, L6, Fl, S24) (Lim.7) 6-inch wide laps spaced 114-inch o.c,,. <e Min.24 ga.R-Panel or Approved Insulation PBR panel metal roofing at filled between ribs. Duro-Last#15 Extra Heavy Duty Drill Point er and max.5ft span and fastened Preliminarily ' e' -45 R-M-5 12-inch o.c.at each support Min.0.5-inch secured DL Duro-Last Cleat Plates or Poly-Plates fastened (Lim.7) with min.#12 HWH screws Approved Insulation 6-inch o.c.within 3-inch wide tabs spaced 60-inch o.c. with min.0.5-inch washers above ribs Steel Deck OPTIONAL Preliminarily Duro-Last#15 Extra Heavy Duty Drill Point Fastener and -45 R-M-6 DL Poly-Plates or Cleat Plates fastened 6-inch o.c. (G33, L6,Fl, SO) Approved Insulation secured along 6-inch wide tabs spaced 120-inch o.c. (Lim.7) Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-7 Steel Deck OPTIONAL Preliminarily DT Cleat Plates fastened 12-inch o.c.within -45 (G33, L6,Fl, S24) Approved Insulation secured (120-inch wide) (Lim.7) 4-inch wide laps spaced 116-inch o.c. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-8 Wood Deck DT Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c.within -45 - -(T19/32, L24, 0.113-6/6) 6-inch wide laps spaced 114-inch o.c.; (Lim.7) fastener centered 1.25-inches from edge of tab Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-9 Steel Deck DT Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c. -45 - -(G33, L6,PW or F1, S24) within 6-inch wide laps spaced 114-inch o.c.; (Lim.7) fastener centered 1.25-inches from edge of tab Min.225 psi LWIC over Duro-Last#15 Extra Heavy Duty Drill Point Fastener and R-M-10 Steel Deck - - DL Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c.within -45 (Min.26 ga. HD-Dek, (Lim.7) 3-inch wide tabs spaced 60-inch o.c. Vented, G80,L5,P, S15) Min.26 ga.R-Panel or Approved Insulation PBR panel metal roofing at filled between ribs. Duro-Last#15 Extra Heavy Duty Drill Point Fastener and Preliminarily -45 R-M-11 max.5ft span and fastened Min.0.5-inch DT Duro-Last Poly-Plates fastened 6-inch o.c. 6-inch o.c.at each support Approved Insulation secured within 6-inch wide laps spaced 54-inch o.c (Lim.7) with min.#12 HWH screws above ribs Duro-Last#15 Extra Heavy Duty Drill Point Fastener and Steel Deck Duro-Last Poly-Plates or Cleat Plates fastened 6-inch o.c.within -52.5 R-M-12 - -(G33, L6, PW, S24) DT 6-inch wide laps spaced 54-inch o.c.; (Lim.7) fastener centered 1.25-inches from edge of tab DLR12001.11 FL#16039-R11 Page 17 of 29 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. w 10153 West Highway 90. Lake City. Fl 32055 • 386-867-4757 ` ;.. www.ENERGYROOFINGCO.coM ENERGY ROOFING FLORIDA LICENSE#"`I3295P' 18 January, 2018 Dear City of Atlantic Beach, Please allow our permit coordinator, Ms. Laura Myers, to act on behalf of myself and Energy Roofing Technology in all aspects of permitting including submitting and picking up permits. If you have any questions, please reach out to me personally on 386.867.4756. Thank you for your consideration in this matter. Kind regards, �, 4 , 1/ ,/ AM Barry D. Joye MGRM FC State of Florida ` Pie County of Columbia The foregoing instrument was acknowledged before me this 18th day of January 2018 by Barry D Joye, as Qualifying Agent of Energy Roofing Technology SE, LLC a Florida corporation, on behalf of the corporation. He is personally known to me, or has provided proper identification. NOTARY SIGNATURE: �,L.[ �( -A s'Ll . ."( r.---1 Notary Printed: 4---3 C'A j e a r-N rl-1),.xa_27-A— My Commission Expires: Ap r-1 I `f) LC12 l (SEAL) 1:4':4',,,t""• . LESLIEANN PIAZZA • `: MY COMMISSION#GG090388 ,?•a te EXPIRES April 04,2021 PAGE 1 OF 1 1/24/2018 Florida Building Code Online warn." FLOtiiCA CCP uswt'rr ov Business & Professional Regulation rnr�- 9 SCIS Home Log In User Registration r Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search d bOr ID Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL16039-R11 SECRETARY Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Duro-Last Roofing Inc. Address/Phone/Email 525 Morley Dr. Saginaw, MI 48601 (989)753-6486 Ext 2296 ajanni@duro-last.com Authorized Signature Janni Al ajanni@duro-Iast.com Technical Representative AL Janni Address/Phone/Email 525 Morley Drive Saginaw, MI 48601 (800)248-0280 ajanni@duro-Iast.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Single Ply Roof Systems Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 (7n Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 06/24/2019 Validated By Locke Bowden (� Validation Checklist- Hardcopy Received A Certificate of Independence FL16039 R11 COI DLR12001.11 2017 FBC Evaluation R rt HVHZ final.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D 4434 2012 ASTM G 155 2005 FM 4470 2012 FM 4474 2011 TAS 110 2000 TAS 114(B,D, H&J) 1995 TAS 117(A) 1995 UL 1897 2012 https://www.floridabuiiding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWeYabPBw%2bDCrJNEhtQhZQW1u7u7jFSGefc%2bjA%3d%3d 1/2 1/24/2018 Florida Building Code Online Equivalence of Product Standards Certified By • Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/27/2017 Date Validated 09/27/2017 Date Pending FBC Approval 10/04/2017 Date Approved 12/12/2017 Summary of Products FL# Model, Number or Name Description 116039.1 I Duro-Last Roofing PVC Single-Ply Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16039 R11 II DLR12001,11 2017 FBC Evaluation Report Approved for use outside HVHZ:Yes NVHZ final.Ddf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: +0/-1025 Created by Independent Third Party: Yes Other: See evaluation report for limits of use Evaluation Reports FL16039 R11 AE DLR12001.11 2017 FBC Evaluation Report HVHZ final.Ddf Created by Independent Third Party: Yes Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida,::privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: ® aC hc.k� Credit Card Safe '.ti tlrit\MI.I kl( CZ‹. ON fr haps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr%2PPBw%2bDCrJNEhtQhZQW1u7u7jFSGefc°/a2bjA%3d%3d 2/2 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing Coop 303 303 Atlantic Blvd. Atlantic Beach, FL 32233 4490 Prepared For: Prepared By: Eric Smith Energy Roofing s I' A P Duro-Last Roof Assembly Description • Duro-Last®Duro-TuffrM membrane Membrane Thickness: 50 mil,nominal Color: White Attachment: Attached with mechanical fasteners • Duro-Guard® ISO II(tapered) Attachment: Attached with mechanical fasteners • Duro-Guard®ISO II(flat) Attachment: Loosely laid • Steel Roof Deck O,<•� Fc 0/ 01/ 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing PART 1 GENERAL 1.1 SECTION INCLUDES A. Duro-Last®Duro-TuffrM membrane attached with mechanical fasteners. B. Duro-Guard®ISO II(tapered),attached with mechanical fasteners. C. Duro-Guard®ISO II(flat), loosely laid. D. Prefabricated flashings, corners,parapets, stacks,vents,and related details. E. Fasteners,adhesives,and other accessories required for a complete roofmg installation. F. Traffic Protection. 1.2 REFERENCES A. NRCA-The NRCA Roofing and Waterproofing Manual. B. ASCE 7-Minimum Design Loads For Buildings And Other Structures. C. UL-Roofing Materials and Systems Directory,Roofing Systems(TGFU.R10128). D. ASTM C 1289-Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board. E. ASTM D 751 - Standard Test Methods for Coated Fabrics. F. ASTM D 4434-Standard Specification for Poly(Vinyl Chloride)Sheet Roofing. G. ASTM E 108-Standard Test Methods for Fire Tests of Roof Coverings. H. ASTM E 119-Standard Test Methods for Fire Tests of Building Construction and Materials. 1.3 SYSTEM DESCRIPTION A. General: Provide installed roofmg membrane and base flashings that remain watertight;do not permit the passage of water; and resist specified uplift pressures,thermally induced movement, and exposure to weather without failure. B. Material Compatibility: Provide roofing materials that are compatible with one another under conditions of service and application required,as demonstrated by roofing membrane manufacturer based on testing and field experience. C. Physical Properties: 1. Roof product must meet the requirements of Type III PVC sheet roofing as defined by ASTM D 4434 and must meet or exceed the following physical properties. 2. Thickness: 50 mil,nominal,in accordance with ASTM D 751. 3. Thickness Over Scrim:>26 mil in accordance with ASTM D 751. 4. Breaking Strengths:>423 lbf.(MD)and>278 lbf.(XMD)in accordance with ASTM D 751, Grab Method. 5. Elongation at Break:>_31%(MD)and>_30%(XMD)in accordance with ASTM D 751,Grab Method. 6. Heat Aging in accordance with ASTM D 3045: 176°F for 56 days.No sign of cracking, chipping or crazing. (In accordance with ASTM D 4434). 075419-1 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 7. Factory Seam Strength:>423 lbf. in accordance with ASTM D 751,Grab Method. 8. Tearing Strength:>_90 lbf. (MD)and> 143 lbf.(XMD)in accordance with ASTM D 751, Procedure B. 9. Low Temperature Bend(Flexibility): Pass at-40 °F in accordance with ASTM D 2136. 10. Accelerated Weathering:No cracking, checking,crazing, erosion or chalking after 5,000 hours in accordance with ASTM G 154. 11. Linear Dimensional Change: <0.20%(MD)and 0.10%(XMD)in accordance with ASTM D 1204 at 176±2°F for 6 hours. 12. Water Absorption: <2.60% in accordance with ASTM D 570 at 158°F for 166 hours. 13. Static Puncture Resistance:>33 lbs. in accordance with ASTM D 5602. 14. Dynamic Puncture Resistance:>_ 14.7 ft-lbf. in accordance with ASTM D 5635. $membrane_certs$ D. Cool Roof Rating Council(CRRC): 1. Membrane must be listed on CRRC website. a. Initial Solar Reflectance:>85% b. Initial Thermal Emittance:>89% c. Initial Solar Reflective Index(SRI):> 108 E. Insulation 1. Provide overall thermal resistance for roofing system as follows: a. Average R-value: 38. 2. Tapered Insulation Slope: 1/8 inch per foot. 3. Configuration as indicated on the Drawings. 1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Duro-Last data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. 4. Maintenance requirements. C. Shop Drawings: Indicate insulation pattern,overall membrane layout,field seam locations,joint or termination detail conditions,and location of fasteners. D. Verification Samples: For each product specified,two samples,representing actual product, color, and fmish. 1. 4 inch by 6 inch sample of roofmg membrane, of color specified. 2. 4 inch by 6 inch sample of walkway pad. 075419-2 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 3. Termination bar,fascia bar with cover,drip edge and gravel stop if to be used. 4. Each fastener type to be used for installing membrane, insulation/recover board,termination bar and edge details. E. Installer Certification: Certification from the roofing system manufacturer that Installer is approved,authorized,or licensed by manufacturer to install roofing system. F. Manufacturer's warranties. 1.5 QUALITY ASSURANCE A. Perform work in accordance with manufacturer's installation instructions. B. Manufacturer Qualifications: A manufacturer specializing in the production of PVC membranes systems and utilizing a Quality Control Manual during the production of the membrane roofing system that has been approved by and is inspected by Underwriters Laboratories. C. Installer Qualifications: Company specializing in installation of roofmg systems similar to those specified in this project and approved by the roofmg system manufacturer. D. Source Limitations: Obtain components for membrane roofmg system from roofmg membrane manufacturer. E. There shall be no deviations from the roof membrane manufacturer's specifications or the approved shop drawings without the prior written approval of the manufacturer. 1.6 REGULATORY REQUIREMENTS A. Conform to applicable code for roof assembly wind uplift and fire hazard requirements. B. Fire Exposure: Provide membrane roofmg materials with the following fire-test-response characteristics.Materials shall be identified with appropriate markings of applicable testing and inspecting agency. 1. Exterior Fire-Test Exposure: a. Class A; ASTM E 108, for application and roof slopes indicated. 2. Fire-Resistance Ratings: Comply with ASTM E 119 for fire-resistance-rated roof assemblies of which roofing system is a part. 3. Conform to applicable code for roof assembly fire hazard requirements. C. Wind Uplift: 1. Roofmg System Design: Provide a roofing system designed to resist uplift pressures calculated according to the current edition of the ASCE-7 Specification Minimum Design Loads for Buildings And Other Structures. 1.7 PRE-INSTALLATION MEETING A. Convene meeting not less than one week before starting work of this section. B. Review methods and procedures related to roof deck construction and roofing system including, but not limited to,the following. 075419-3 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 1. Meet with Owner,Architect,Owner's insurer if applicable,testing and inspecting agency representative,roofing installer,roofing system manufacturer's representative,deck installer, and installers whose work interfaces with or affects roofing including installers of roof accessories and roof-mounted equipment. 2. Review and finalize construction schedule and verify availability of materials, installer's personnel,equipment,and facilities needed to make progress and avoid delays. 3. Examine deck substrate conditions and finishes for compliance with requirements, including flatness and fastening. 4. Review structural loading limitations of roof deck during and after roofing. 5. Review base flashings,special roofmg details,roof drainage,roof penetrations,equipment curbs,and condition of other construction that will affect roofing system. 6. Review governing regulations and requirements for insurance and certificates if applicable. 7. Review temporary protection requirements for roofing system during and after installation. 8. Review roof observation and repair procedures after roofing installation. 1.8 DELIVERY, STORAGE AND HANDLING A. Deliver roofing materials to Project site in original containers with seals unbroken and labeled with manufacturer's name,product brand name and type,date of manufacture,and directions for storing and mixing with other components. B. Store liquid materials in their original undamaged containers in a clean,dry,protected location and within the temperature range required by roofing system manufacturer.Protect stored liquid material from direct sunlight. C. Protect roof insulation materials from physical damage and from deterioration by sunlight, moisture, soiling,and other sources. Store in a dry location.Comply with insulation manufacturer's written instructions for handling, storing,and protecting during installation. D. Store roof materials and place equipment in a manner to avoid permanent deflection of deck. E. Store and dispose of solvent-based materials,and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction. 1.9 WARRANTY A. Contractor's Warranty: The contractor shall warrant the roof application with respect to workmanship and proper application for two(2)years from the effective date of the warranty issued by the manufacturer. B. Manufacturer's Warranty:Must be no-dollar limit type and provide for completion of repairs, replacement of membrane or total replacement of the roofing system at the then-current material and labor prices throughout the life of the warranty. In addition the warranty must meet the following criteria: 1. Warranty Period: 15 years from date issued by the manufacturer. 2. No exclusion for damage caused by ponding water. 3. No exclusion for damage caused by biological growth. 4. Issued direct from and serviced by the roof membrane manufacturer. 5. Transferable for the full term of the warranty. 075419-4 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 6. No additional charge for the warranty. PART 2 PRODUCTS 2.1 MANUFACTURER A. Manufacturer:Duro-Last Roofing,Inc.,which is located at: 525 Morley Drive, Saginaw, MI 48601. Telephone: 800-248-0280. B. All roofing system components to be provided or approved by Duro-Last Roofing,Inc. C. Substitutions: Not permitted. 2.2 ROOFING SYSTEM COMPONENTS A. Roofing Membrane: Duro-Last®Duro-TuffrM membrane conforming to ASTM D 4434,type III, fabric-reinforced,PVC,NSF/ANSI 347 Gold or Platinum Certification,and a product-specific third-party verified Environmental Product Declaration. Membrane properties as follows: 1. Thickness: a. 50 mil,nominal. 2. Exposed Face Color: a. White. 3. Minimum recycle content 7%post-industrial and 0%post-consumer. 4. Recycled at end of life into resilient flooring or concrete expansion joints. B. Accessory Materials: Provide accessory materials supplied by or approved for use by Duro-Last Roofmg,Inc. 1. Sheet Flashing: Manufacturer's standard reinforced PVC sheet flashing. 2. Duro-Last Factory Prefabricated Flashings: manufactured using Manufacturer's standard reinforced PVCmembrane. a. Stack Flashings. b. Curb Flashings. c. Inside and Outside Corners. 3. Sealants and Adhesives: Compatible with roofing system and supplied by Duro-Last Roofmg, Inc. a. Duro-Caulk®Plus. b. Strip Mastic. 4. Slip Sheet: Compatible with roofing system and supplied by Duro-Last Roofing,Inc. 5. Fasteners and Plates: Factory-coated steel fasteners and metal or plastic plates meeting corrosion-resistance provisions in FMG 4470,designed for fastening membrane and insulation to substrate. Supplied by Duro-Last Roofing,Inc. a. #14 Heavy Duty Fasteners. b. Cleat Plates. c. 3 inch Metal Plates. 6. PV Anchors 075419-5 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 7. Termination and Edge Details: Supplied by Duro-Last Roofmg,Inc. a. Termination Bar. b. Universal 2-Piece Compression Metal System. 8. Vinyl Coated Metal: Supplied by Duro-Last Roofmg,Inc.24 gauge,hot-dipped galvanized, grade 90 metal with a minimum of 17 mil of Duro-Last membrane laminated to one side. 9. Two-Way Roof Vents: Supplied by Duro-Last Roofing,Inc. Install a minimum of 1 vent for each 1,000 ft2(93 m2)of roof area. C. Walkways: 1. Provide non-skid,maintenance-free walkway pads in areas of heavy foot traffic and around mechanical equipment. a. Duro-Last Roof Trak®III Walkway Pad. 2.3 ROOF INSULATION A. General: 1. Provide preformed roof insulation boards that comply with requirements and referenced standards,as selected from manufacturer's standard sizes. 2. Provide preformed saddles,crickets,and other insulation shapes where indicated for sloping to drain. Fabricate to slopes indicated. B. Polyisocyanurate Board Insulation: Complying with ASTM C 1289,Type II,felt or glass-fiber mat facer on both major surfaces.Material as supplied by Duro-Last. 1. Duro-Guard®ISO II(flat). 2. Duro-Guard®ISO II(tapered). 2.4 ROOF INSULATION ACCESSORIES A. General: Provide roof insulation accessories approved by the roof membrane manufacturer and as recommended by insulation manufacturer for the intended use. B. Fasteners: Provide Duro-Last factory-coated steel fasteners and metal or plastic plates meeting corrosion-resistance provisions in FMG 4470,designed for fastening insulation and/or insulation cover boards in conformance to specified design requirements. 1. PART 3 EXECUTION 3.1 EXAMINATION A. Verify that the surfaces and site conditions are ready to receive work. B. Verify that the deck is supported and secured. C. Verify that the deck is clean and smooth,free of depressions,waves,or projections, and properly sloped to drains,valleys, eaves, scuppers or gutters. D. Verify that the deck surfaces are dry and free of standing water, ice or snow. E. Verify that all roof openings or penetrations through the roof are solidly set. F. If substrate preparation is the responsibility of another contractor,notify Architect of 075419-6 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing unsatisfactory preparation before proceeding. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation. B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. C. Surfaces shall be clean, smooth,free of fins,sharp edges, loose and foreign material,oil, grease, and bitumen. 3.3 INSTALLATION A. Install insulation in accordance with the roof manufacturer's requirements. B. Insulation: Duro-Guard®ISO II(flat)and Duro-Guard®ISO II(tapered). 1. Install insulation in accordance with the roof manufacturer's requirements. 2. Insulation shall be adequately supported to sustain normal foot traffic without damage. 3. Where field trimmed, insulation shall be fitted tightly around roof protrusions with no gaps greater than 1/4 inch. 4. Tapered insulation boards shall be installed in accordance with the insulation manufacture's shop drawings. 5. No more insulation shall be applied than can be covered with the roof membrane by the end of the day or the onset of inclement weather. 6. If more than one layer of insulation is used,all joints between subsequent layers shall be offset by at least 6 inches. 7. Mechanical Attachment:Use only fasteners, stress plates and fastening patterns accepted for use by the roof manufacturer.Fastening patterns must meet applicable design requirements. a. Install fasteners in accordance with the roof manufacturer's requirements. Fasteners that are improperly installed must be replaced or corrected. 8. Loosely lay Duro-Guard®ISO II(flat)and then overlay with Duro-Guard®ISO II(tapered). Install mechanical fasteners through top layer to attach insulation.Install all layers in parallel courses with end joints staggered 50%and adjacent boards butted together with no gaps greater than '/4 inch. C. Roof Membrane: 50 mil,nominal, Duro-Last®Duro-Tuffr'"membrane. 1. Use only fasteners, stress plates and fastening patterns accepted for use by the roof manufacturer.Fastening patterns must meet the applicable design requirements. 2. Install fasteners in accordance with the roof manufacturer's requirements. Fasteners that are improperly installed shall be replaced or corrected. 3. Mechanically fasten membrane to the structural deck utilizing fasteners and fastening patterns that in accordance with the roof manufacturer's requirements. 4. Cut membrane to fit neatly around all penetrations and roof projections. 5. Unroll roofing membrane and positioned with a minimum 6 inch overlap. D. Seaming: 1. Weld overlapping sheets together using hot air.Minimum weld width is 1-1/2 inches. 075419-7 3-Part Specification Division 07 54 19-Polyvinyl-Chloride Roofing 2. Check field welded seams for continuity and integrity and repair all imperfections by the end of each work day. E. Membrane Termination/Securement:All membrane terminations shall be completed in accordance with the membrane manufacturer's requirements. 1. Provide securement at all membrane terminations at the perimeter of each roof level,roof section,curb flashing, skylight,expansion joint,interior wall,penthouse,and other similar condition. 2. Provide securement at any angle change where the slope or combined slopes exceeds two inches in one horizontal foot. F. Flashings: Complete all flashings and terminations as indicated on the drawings and in accordance with the membrane manufacturer's requirements. 1. Provide securement at all membrane terminations at the perimeter of each roof level,roof section,curb flashing, skylight,expansion joint, interior wall,penthouse,and other similar condition. a. Do not apply flashing over existing thru-wall flashings or weep holes. b. Secure flashing on a vertical surface before the seam between the flashing and the main roof sheet is completed. c. Extend flashing membrane a minimum of 6 inches(152 mm)onto the main roof sheet beyond the mechanical securement. d. Use care to ensure that the flashing does not bridge locations where there is a change in direction(e.g.where the parapet meets the roof deck). 2. Penetrations: a. Flash all pipes,supports, soil stacks,cold vents, and other penetrations passing through the roofing membrane as indicated on the Drawings and in accordance with the membrane manufacturer's requirements. b. Utilize custom prefabricated flashings supplied by the membrane manufacturer. c. Existing Flashings: Remove when necessary to allow new flashing to terminate directly to the penetration. 3. Pipe Clusters and Unusual Shapes: a. Clusters of pipes or other penetrations which cannot be sealed with prefabricated membrane flashings shall be sealed by surrounding them with a prefabricated vinyl- coated metal pitch pan and sealant supplied by the membrane manufacturer. b. Vinyl-coated metal pitch pans shall be installed,flashed and filled with sealant in accordance with the membrane manufacturer's requirements. c. Pitch pans shall not be used where prefabricated or field fabricated flashings are possible. G. Roof Drains: 1. Coordinate installation of roof drains and vents specified in Section 15146-Plumbing Specialties. 2.. Remove existing flashing and asphalt at existing drains in preparation for sealant and membrane. 3. Provide a smooth clean surface on the mating surface between the clamping ring and the drain base. 075419-8 3-Part Specification • Division 07 54 19-Polyvinyl-Chloride Roofing H. Edge Details: 1. Provide edge details as indicated on the Drawings. Install in accordance with the membrane manufacturer's requirements. 2. Join individual sections in accordance with the membrane manufacturer's requirements. 3. Coordinate installation of metal flashing and counter flashing specified in Section 07620. 4. Manufactured Roof Specialties: Coordinate installation of copings,counter flashing systems, gutters,downspouts,and roof expansion assemblies specified in Section 07710. I. Walkways: 1. Install walkways in accordance with the membrane manufacturer's requirements. 2. Provide walkways where indicated on the Drawings. 3. Install walkway pads at roof hatches,access doors,rooftop ladders and all other traffic concentration points regardless of traffic frequency.Provided in areas receiving regular traffic to service rooftop units or where a passageway over the surface is required. 4. Do not install walkways over flashings or field seams until manufacturer's warranty inspection has been completed. J. Water cut-offs: 1. Provide water cut-offs on a daily basis at the completion of work and at the onset of inclement weather. 2. Provide water cut-offs to ensure that water does not flow beneath the completed sections of the new roofing system. 3. Remove water cut-offs prior to the resumption of work. 4. The integrity of the water cut-off is the sole responsibility of the roofing contractor. 5. Any membrane contaminated by the cut-off material shall be cleaned or removed. 3.4 FIELD QUALITY CONTROL A. The membrane manufacturer's representative shall provide a comprehensive final inspection after completion of the roof system. All application errors shall be addressed and fmal punch list completed. 3.5 PROTECTION A. Protect installed roofing products from construction operations until completion of project. B. Where traffic is anticipated over completed roofing membrane,protect from damage using durable materials that are compatible with membrane. C. Repair or replace damaged products after work is completed. END OF SECTION 075419-9 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: CPOpi 311 Permit # Project Address: ; _ _ I_.� ►i /. �di�i._ . .n r/. _ As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide iroduct approval may be obtained at: www.floridabuilding.oru1. Category/Subcategory 1 Manufacturer Product Description I Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Roll up 5. Automatic 6. Other B. WINDOWS 1. Single hung 2. Horizontal slider 3. Casement I 4. Double hung }� 5. Fixed E)` 6. Awning 7. Pass-through ao 8. Projected • 9. Mullion 10. Wind breaker 11. Dual action 12. Other Category/Subcategory Manufacturer Product Description jLimitation of Use State# Local# C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles • 2. Underlayments 3. Roofing fasteners Puled - St- -4 (5) N(Io6 -rz-(I 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing D.Jufn_ l Q S+ YLllo D3q-ltll 8. Roofing tiles 9. Roofing insulation �' tcL-_ 5(04), 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats p� 15. Roof tile adhesive 16. Spray applied polyurethane roof l 17. Other Category/Subcategory Manufacturer J Product Description f Limitation of Use State# Local# E.SHUTTERS 1. Accordion 2. Bahama • 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor 2. Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof II. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other . ' Category/Subcategory Manufacturer 1 Product Description 1Limitation of Use State# Local# H.NEW EXTERIOR II ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) ?cur rty J 0 (Signature) Company Name: AA 0 ►_ Mailing Address: lo u) US w y cti City: LCAX.Q State: pi_ Zip Code:_a_ 116 Telephone Number: ( 855 ) /1.Q(D - 38 S.2— Fax Number: ( ) Cell Phone Number: (3 g(.Q) Su-t - .T5(P E-mail Address: ,,, • , ' � /,_ / . -1/1,1L, V1.4) -!- Product Data Sheet ULE-HIDE MULE-HIDE POLY ISOI TM ROOF INSULATION • 4116.40/ PRODUCTS M S PRODUCT DESCRIPTION The Mule-Hide Poly ISO 1 TM polyisocyanurate insulation (flat or tapered) is a closed-cell polyisocyanurate foam core laminated to (non-asphaltic) glass fiber reinforced felt facers. The Mule-Hide Poly ISO 1 is compatible with all Mule- Hide membranes and accessories.Available in 20 psi and 25 psi. BASIC USES The Mule-Hide Poly ISO 1T" insulation board may be used for ballasted, mechanically attached and fully adhered single- ply roofing systems. The Poly ISO 1 TM insulation board may be installed over approved decks and substrates on new construction, tearoffs, and recover (retrofit) projects. The Poly ISO 1 TM insulation board may be used in UL Class A and FM Class 1 assemblies. BENEFITS & SUPPLEMENTAL STATEMENTS • Approved for direct application to steel decks • Mule-Hide Poly ISO 1 TM is manufactured with NexGen Chemistry: Contains no CFCs, HCFCs, is Zero ODP, EPA Compliant and has virtually no GWP • Available as 4' x 4'or 4' x 8' panels in Grade 2 (20 psi)or Grade 3 (25 psi / • Thicknesses range from 1"to 4.5" C 4$' TYPICAL PHYSICAL PROPERTIES /'� 6J,4 Property Test Method Typical Results Dimensional Stability ASTM D-2126 2% Linear Change (7 days) Compressive Strength ASTM D-1621 20 PSI (Grade 2)25 PSI (Grade3) Water Absorption ASTM D-209 Less than 1% By Volume Moisture Vapor Transmission ASTM E-96 Less than One (1)Perm Service Temperature --- -100°F to 250°F Max Flame Spread (foam core) ASTM E 84 <75** Smoke Development ASTM E 84 <450** 'The physical properties above are presented as typical average values as determined by accepted ASTM test methods and are subject to change. All information can be confirmed by contacting Mule- Hide Products. "The numerical ratings are determined by ASTM Test Method E-84 are not intended to reflect hazards presented by this or any other material under actual fire conditions. A flame spread index of 75 or less and smoke development of 450 or less meet code requirements regarding flame spread and smoke development for foam plastic roof insulation. However,the codes exempt foam plastic insulation when used ri roof deck constructions that comply as an assembly with FM 4450 or UL 1256(see IBC,NBC, UBC and SBS Sections on Foam Plastic Insulation(Chapter 26). Smoke development does not apply to roofing LTTR ASTM C1289-11 Poly1SO TM Recycle Content Value (revised Jan-2014) 20 2 layers of 1.8" Poly ISO Between 16% and 43 % by weight, depending upon 25 2 layers of 2.2" Poly ISO thickness (55% post consumer and 45% post industrial). 30 2 layers of 2.6" Poly ISO Refer to Mule-Hide LEED memo. 35 2 layers of 3.1" Poly ISO 40 2 layers of 3.5" Poly ISO Revised:March-2017 PDS 09-6210 Page 1 of 3 Product Data Sheet MULE-HIDE POLY ISO1 TM ROOF INSULATION fmsinomm_ TYPICAL PHYSICAL PROPERTIES (Continued) Poly ISO 1r" Nominal Thickness** LTTR R-Value C-Value Metal Deck Max. Flute (mm)mm) (revised Jan-2014) 1.0 25 5.7 .175 2% 1.5 38 8.6 .116 4 % 1.8 46 10.3 .097 4% 2.0 51 11.4 .088 4'/e 2.5 64 14.4 .069 4'/e 2.6 66 15.0 .067 _ 4% 3.0 76 17.4 .057 4% 3.5 89 20.5 .049 4% 3.8 97 22.3 .045 4 % 4.0 102 23.6 .042 4 % 4.3 109 25.5 .039 4% 4.5 114 26.8 .037 4% *Long Term Thermal Resistance Values are based on ASTM C1289(revised Jan-2014)and CAN/ULC S770 which provides for a 15-year time weighted average. "Other thicknesses available upon special request. SUPPLIMENTAL INFORMATION PROFILES 2.5` 6.5' 1 .0 2.0 3.0 ' 1 .5" 3 ' 0.5- 4 5 ' .; .. 1 0 2.5" .5" 0.5- 41 0 01 I 02 AA A C AA1 A l.1X v h iY TfL'._ BELOW FILL BELOW CI I F.-3-,, OA P ‘'Q 441/111 1� OPEi ® 2 0 1/8.. ELOPE----- A /a.. s x v 2.0 s0 Mara d i; - 2.O" iSG X y 2.0' i50 PACKAGING Factory applied packaging is only intended for protection during transit.When stored outside or at the job site, the insulation must be stored at least 4"above ground level and completely covered with a weatherproof covering such as a tarpaulin. Warning-Do Not Leave Exposed: This product will burn if exposed to an ignition source of sufficient heat and intensity,or an open flame. CODE APPROVALS/COMPLIANCE Poly ISO 1 TM complies with the requirements of the following specifications, test and code requirements when properly installed. * Federal Specification HH-I-1972/GEN and HH-I-1972/2, Class 1 *ASTM C 1289-05a, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) * FM Standard 4450/4470 Approval, Class 1 * UL Standard 1256 Classification Page 2 of 3 PDS 09-6210 Revised March-2017 Product Data Sheet MULE-HIDE POLY ISO1 TM ROOF INSULATION CODE APPROVALS/COMPLIANCE (continued) * UL Standard 790 Classification * UL Standard 263 Fire Resistance Classification INSTALLATION INSTRUCTIONS Ballasted Single-Ply Membrane Systems-Mule-Hide Poly ISO 1 TM does not require attachment to the deck in this system. All boards must be tightly fitted together to prevent movement, separation or damage during the installation of the membrane system.All gaps greater than 1/4" must be filled.After the membrane is installed, sufficient amounts of ballast must be applied to prevent membrane and insulation movement. Refer to the Mule- Hide Manual and FM Loss Prevention Data Sheet 1-29 for information regarding ballasting guidelines. Mechanically Attached Single-Ply Membrane Systems- Mule-Hide Poly ISO 1 T"' should be attached with Mule-Hide fasteners and insulation plates(or FM Approved fasteners)using a minimum of 4 fasteners per 4'x 4' board (1 fastener per 4 square feet)and a minimum of 6 fasteners per 4'x 8' board (1 fastener per 5.33 square feet). Refer to the Mule-Hide Manual for proper fastener placement. Fully Adhered Single-Ply Membrane Systems-Mule-Hide Poly ISO 1 TM should be installed with the perforated side down. Insulation attachment will vary depending upon insulation thickness and job requirements. If the top layer is less than 2"thick, install a minimum of 8 fasteners per 4'x 4'board (1 fastener per 2 square feet)and a minimum of 16 fasteners per 4'x 8' board (1 fastener per 2 square feet). If the top layer is 2"thick or thicker, install 4 fasteners per 4'x 4' or 8 fasteners per 4'x 8' insulation board. Refer to the Mule-Hide Manual for proper fastener density and placement. Additional fastening may be required for certain job conditions. In some instances hot steep asphalt or insulation adhesive may be used to attach the Mule-Hide Poly ISO 1 Eto approved concrete decks. Only 4'x 4'boards may be used. Contact Mule-Hide's Technical Department for specific requirements and procedures. PROTECTION & SAFETY Mule-Hide maintains Safety Data Sheets on all of its products. Safety Data Sheets contain health and safety information for your development of appropriate product handling procedures to protect your employees and customers. Mule-Hide's Safety Data Sheets should be read and understood by all of your supervisory personnel and employees before using Mule-Hide products in your facilities. ADDITIONAL INFORMATION The information given on this PDS is subject to change without notice. Always check the Mule-Hide website at www.mulehide.com for the latest information, changes and updates or contact Mule-Hide Products Company at 800-786-1492. DISCLAIMER The statements provided concerning the material shown are intended as a guide for material usage and are believed to be true and accurate at the time of printing. No statement made by anyone may supersede this information,except when done in writing by Mule-Hide Products Co.,Inc. Since the manner of use is beyond our control,Mule-Hide does not authorize anyone to make any warranty of merchantability or fitness for any particular purpose or any other warranty,guarantee or representation,expressed or implied,concerning this material. Buyer and user accept the product under these conditions and assume the risk of any failure,any injury person or property(including that of the user),loss or liability resulting from the handling,storage or use of the product whether or not it is handled,stored or used in accordance with the directions or specifications. Mule-Hide must be notified in writing of any claims and be given the Revised:March-2017 PDS 09-6210 Page 3 of 3