Loading...
568 Timber Bridge Lane NEW HOME rib f CITY OF ATLANTIC BEACH ...7.:v, -:‘, . s-) 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 , o13»%' INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0064 Description: new single-family home Estimated Value: 386578.9 Issue Date: 2/27/2018 Expiration Date: 8/26/2018 PROPERTY ADDRESS: Address: 568 TIMBER BRIDGE LN RE Number: 169505 2135 PROPERTY OWNER: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD HORSHAM, PA 19044 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: TOLL BROS.,INC Address: 250 GIBRALTAR RD STEVEN R MERTEN HORSHAM, PA 19044 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. �3 ow, Permit Conditions fel 1511+ t� City of Atlantic Beach Permit Number: RES18-0064 Description: new single-family home Applied: 2/9/2018 Approved: 2/22/2018 Site Address: 568 TIMBER BRIDGE LN Issued:2/27/2018 Finaled: City,State Zip Code:ATLANTIC BEACH, FL 32233 Status: ISSUED Applicant: <NONE> Parent Permit: Owner:TOLL FL VI LIMITED PARTNERSHIP Parent Project: Contractor: <NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 2/14/2018 DRIVEWAY APRON INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All concrete driveway aprons must be 5"thick,4000 psi,with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of-way. (Commercial driveways-6"thick). 2 2/14/2018 EROSION CONTROL INSTALLATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(247- 5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 3 2/14/2018 ON SITE RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site during construction. 4 2/14/2018 ROLL OFF CONTAINER INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapell's,Inc.,Republic Services,Donovan Dumpsters). Container cannot be placed on City right-of-way. 5 2/14/2018 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. Printed:Tuesday, 27 February, 2018 1 of 2 1 r' 't Permit Conditions J� City of Atlantic Beach -& Ur 6 2/14/2018 RUNOFF INFORMATIONAL • PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site. Cannot raise lot elevation. 7 2/14/2018 MAXIMUM DRIVEWAY INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Maximum driveway width within the City right-of-way is 20'. 8 2/20/2018 UNDERGROUND WATER SEWER INFORMATIONAL UTILITIES PUBLIC WORKS Kayle Moore Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5834. 9 2/20/2018 METER BOX SEWER CLEAN OUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible. 10 2/20/2018 RT1 SEWER CLEANOUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. Printed:Tuesday, 27 February, 2018 2 of 2 • S�.Lv City of Atlantic Beach APPLICATION NUMBER js iii: Building Department (To be assigned by the Building Department.) 800 Seminole Road% Q e 5 t <e Ov 0`I - Atlantic Beach, Florida 32233-5445 t'- 1 Phone(904)247-5826 • Fax(904)247-5845 a I li I 1 'j 0.709 E-mail: building-dept@coab.us Date routed: `" l Q City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: S p ( <in { 606_,(A Department review required Yes o Applicant: t 0\ V \S'(1:DS- C• (Planning &Zoning 7) J Tree Administrator Project: 0 C.•v,' Si iNc \Q Ca (NA i lit co/Lk = or s Public Utilities _. Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: UILDIN PLANNING &ZONING Reviewed by: {' y Date:e2 '/6•o?b/ I TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 i+;-,0,iCity of Atlantic Beach APPLICATION NUMBER :i' ,,F \Sl Building Department (To be assigned by the Building Department.) r , ;,_. -,\ 800 Seminole Road {/ c(]r^lI �� si Atlantic Beach, Florida 32233-5445 t` _<_-,1 ?) -coo (I r� _J~ Phone (904)247-5826 • Fax(904) 247-5845 m I L,;;��' E-mail: building-dept@coab.us Date routed: ` I l City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: S (J <<rn4 ', L -�1 Department review required Yes No Applicant: (0‘ j i()C• _ ;. Planning &Zoning J Tree Administrator Project: ()Li/3 S i i, Q -.C.-G{ M , ki, CA COA P- a "or s L Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: /Approved. I (Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: Date /7(`— ( �j 0 TREE ADMIN. Second Review: I 'Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. I (Denied. Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 r.W./yCity of Atlantic Beach APPLICATION NUMBER rs * �? Building Department (To be assigned by the Building Department.) `� 800 Seminole Road r' : 1 9 Q �! --pv/„ I . s, � ° �C�� `. � s1 v.��I Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247,.5$x¢51 2 2910 a I I '�Js3 9',4E-mail: building-dept@coab.us tl�jj �Iv Date routed: l 1 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: S ( p ( <( -- \ 1. Ut Department review required Yes No Applicant: (Q` eY • tL• � Planning &Zoning Tree Administrator Project: n t -) S he \Q c (`t u.'+A-k C P or cs L Public Utilities _) Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: i/Approved. Denied. []Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: —al, TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 rS+ \w City of Atlantic Beach APPLICATION NUMBER �5 Building Department „ (To be assigned by the Building Department.) �— 2 800 Seminole Road w"'-- /�� Atlantic Beach, Florida 32233-5445 6 2 2018 5l -coo (' / Phone(904)247-5826 - Fax(904)2 5845 �� I �) I , ! l yr E-mail: building-dept@coab.us Date routed: l"t S/ City web-site: http://www.coab.us BY. APPLICATION REVIEW AND TRACKING FORM PropertyAddress: $ (0 % <<frl _; \ Lit- Department review required Yes No disrwiD Applicant: (OU eY D 1-n(".... Planning &Zoning ; J Tree Administrator Project: 0 ti/3 Si f\5\0 c-Ct Pa i ('L UV.QC Pubti-Eor�r s ) Public Utilities) Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPyCATION STATUS Reviewing Department First Review: rylApproved. I 'Denied. Not applicable (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: 11 ate: 011 TREE ADMIN. Second Review: I /Approved as revised. ❑Denied. ❑Not applicable PU;,�pRKS..—A— >m ts: 'UBL(,C UT1L-I(y PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. I Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application 0pdat i7/8/17 ° '" YrCity of Atlantic Beach r ce • 800 Seminole Road,Atlantic Beach,FL 32233 r C D 8 2nt Phone:(904)247-5826 Fax:(904)247-5845 Job Address: 568 Timber Bridge Lane Permit Number: RE--S i 5( - 001, Legal Description Lot 175 Atlantic Beach Country Club Unit 2, Parcel #67-52 16-25-29E RE# 169505-2135 Valuation of Work (Replacement Cost)$347880 _Heated/Cooled SF 3026 Non-Heated/Cooled 914 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s) (Circle one): Commercial Residential • If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New home construction Florida Product Approval#See attached for multiple products use product approval form Property Owner Information Name: Toll FL VI Limited Partnership Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904-217-0739 E-Mail aregnier@tollbrothers.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Toll FL VI,LP Contractor Information Name of Company: Toll Bros., Inc Qualifying Agent: Steven R. Merten Address 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904-595-5243 Job Site/Contact Number 904-595-5243 State Certification/Registration# CGC1510225 E-Mail aregnier@tollbrothers.com Architect Name&Phone# Toll Architecture(407)248-5800 Engineer's Name& Phone# Lou Pontigo&Associates(904)242-0908 Workers Compensation Policy#MWC30267702/Expries 9/1/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTO'., EY BEFORE RECORDING YOU OTICE OF COMMENCEMENT. Sig re of Owner or Agent) .gnature of Contractor) (including contractor) Signed and sworn to(or affirmed)before me this 2 f day of Signed and sworn to(or affirmed)before me this 2-4 day of J fwUar1 , , by St21/2 nief/z4A-- Janl(iyLf , av18 ,by SAn'le(}.e,ry ( ure of Notary) (S..: a e of Notary) Personally Kno Personally Known OR oxr Pty, Notary Public State of Florida [ ]Produced Identi a ° Notary Public State of Florida [ ]produced Identificatio Melissa Sue Lieberman Melissa Sue Lieberman My Commission GG 126088 Type of Identificati. :• ; My Comn-asion G 126088 Type of Identification: r :2021 'W' Expires 09/18/2021 °f Of 1k A rrn, 4 SES/,;F-- DDG NOTICE OF COMMENCEMENT JOB COPY State of: FLORIDA Tax Folio No. 169505-2135 . County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 175 Atlantic Beach Country Club Unit 2,67-132 08-2S-29E.152 Address of property being improved: 568 TIMBER BRIDGE LANE,ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 160 CAPE MAY AVE.,PONTE VEDRA,FL 32081 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: )090 ntractor: TOLL BROS.,INC. / Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 �`�' Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) . Address: Amount of Bond$ Telephone No: Fax No. Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN,Division President Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)ye;B from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER yy Signed: Date: Before me is 2(l day of .4 L/! _A) in the Coun1/2 of t.Johns, State Of ,prida,has personally appeared ,5/Pt/e /L/Ca_e✓t Doc#2018027784,OR BK 18273 Page 1358, - tary Public at Large,State o[Fl rida,County of ST.JOHNS. Number Pages: 1 commission expires: �'I ) ,, -/ / • Recorded 02/05/2018 11:58 AM, sonally Known: V //\ )..-or' __ RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL duced Identificatio ,-,: - . - J / COUNTY i �r Notary Public State of Florida ! ( `1 RECORDING $10.00 ' f Melissa Sue Lieberman ___,/ y. x ' My Commission GG 128068 bn6 n# Expires 09/16/2021 :.a9Z _ , r r\4/r�,, �� i J� City of Atlantic Beach PUBLIC UTILITIES DEPARTMENT .-, 1200 Sandpiper Lane J `~eow Atlantic Beach, FL 32233 `cm yr (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date 7 `( q —( 0 Project Address_5(, e ( ( vvi( ' it2_ -eriic — Number of Units Commercial Residential `'/ Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) 1/4 New Irrigation Meter Upgrade Existing Meter from to (size) r► J� New Reclaim Water Meter Size r New Connection to City Sewer V Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature ciCITY STAFF USE ONLY Application# ►CES I D000 (1-6 c( Water System Development Charge $ 1J Sewer System Development Charge $ Water Meter Only $ t S t LSO Reclaim Meter Only $ ( 871 Go Water Meter Tap $ Sewer Tap $ Cross Connection $ 53, Other $ TOTAL $ (CJ i a Oa (Notes) APPROVED Kayle Moore, P.E. �wA, Date 7/x0 4 V Public Utilities Director or Authorized Signature l ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED F, REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT, issued on this day of ,20 , by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and TOLL FL VI.LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach Right-of-Way Permit# . This work is generally described as Pavers in the Right-of-Way for the driveway. • Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested,to the following address 568 Timber Bridge Lane Parcel#67-132 08-2S-29E . • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of public right-of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any v e work herein under the terms of this permit and that all of said liabilities are hereby assumed by the UX. / Date l Z l G Property Owner: .tev• erten,Division President,TOLL FL VI,LP (signed in prese, e of 'otary Public) STATE OF FLORIDA,COUNTY OF SAINT JOHNS The foregoing instrument was acknowledged this 02(1 J day of UXtt . ,201 , by S 1P& Vk4 PJ,L.I , ,who personally( appeared before me and (printed name of Signer) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. ,./ Signa ,e of No . Public,State of Florida Approved /Public Works Department: Personally Known 7-- Produced Identification(Type) -...—le 6 e kl A.)4 r;#7%;,, ki,t, Notary Public State of Florida Melissa Sue Lieberman Scott Williams, ubo�Director 5 y < My Commission GG 126068 $apdg Expires 09/18/2021 t ''' 'y RIGHT-OF-WAY/EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 568 Timber Bridge Lane Phone 904-595-5243 Permittee Steven Merten Email aregnier(a)tollbrothers.com Requesting Permission to Construct Pavers in the Right of Way for the driveway Location(Reference to Cross-Street) Timber Bridge Lane&Atlantic Beach Dr. -06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Stacia Moore (Project Superintendent) located at 237 9th Avenue North,Suite 4,Jacksonville Beach,FL 32250 • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost : expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights . : . ivileges. • The Director of Pip, # orks shall be notified twenty-four(24)hours prior to starting work and again immediately up y o' p,•tion. , (/2 ith le Date Permittee: Steven R. erte D' ision President,TOLLFL VI,LP(signed in presence of Notary Public STATE OF FLORIDA,COUNTY OF SAINT JOHNS The foregoing instrument was acknowledged this 24 day of jailUCU1,� ,20I' , by Ve. tier Iv, , ,who personally appeared before me and (printed name of Permittee) ackn• .,-d that he/she signed the instrument voluntarily for the purpose expressed in it. _ Personally Known Si! -of . . Pub; ,� • Notary Public State of Florida Produced Identification(Type) Melissa Sue Lieberman 9- My Commission GG 128088 N?,„a Expires 09/18/2021 _ . ______.__ _ __ _____________ __________ ____ ,,,, ...: icor 71-Ae Sila/-0 0 1 nordet. N'' FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method . Project Name: Davenport Bonus 3026 Right N Builder Name: Toll Brothers • ' Street: Lot 175 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: _ Owner: Toll Brothers .Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. WallTypes(3577.8 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 3397.80 ft2 .2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 180.00 ft2 3. Number of units,If multiple family 1 •- c.N/A R= ft2 •4. Number of Bedrooms 4 • 'd.N/A R= ft2 10.Ceiling Types (2271.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1997.00 ft2 6. Conditioned floor area above grade(ft2) 3026 , b.Under Attic(Vented) • R=19.0 274.00 ft2 • c.-N/A R= .ft2 • Conditioned floor area below grade(ft2) 0s. • 11.Ducts R ft2 7. Windows(318.0 sqft.) Description Area I a.Sup:Attic,Ret:Attic,AN:Garage 6 414 •a. .U-Factor: Dbl,U=0.34 318.00 ft2 SHGC: SHGC=0.27 12.Cooling systems kBtu/hr Efficiency •• b. U-Factor: N/A ft2 • a.Central Unit -42.0 SEER:14.00 SHGC: , c. U-Factor: N/A -ft2 SHGC: 13.Heating systems kBtu/hr Efficiency • d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.579-ft. 14.Hot water systems i Area Weighted Average SHGC: 0.270 a.Natural Gas Tankless Cap: 1 gallons 8. Floor Types (3026.0 sqft.) Insulation Area EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 .2272.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 691.00 ft2 None c.other(see details) R= 63.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 73.61 .. :PASS Glass/Floor Area: 0.105 Total Baseline. Loads: 81.37 . �,�if/Ni.Ni4 �a ,�'`'KliE ST '4 I hereby certify that the plans and specifications covered by Review of the plans and _.. ...,9r h this calculation are in compliance with the Florida Energy specifications covered by this ;.�� a��+ 43... .;0�, calculation indicates compliance ira.' vu� ,01,f'�=_ ':.': "{' a Code. ,,,.,ti / with the Florida Energy Code. parr( " �+ PREPARED BY: �i�� h vo..�rh ' Before construction is completed �. :-.14,.71._ e? DATE:' e'er'e9'- .-e '/Pg` this building will be inspected for ch �fk"r ori , 3 • compliance with Section 553.908 ` •. s 2r I hereby certify that this b ilding,as designed,is in compliance Florida Statutes. •v1)-'- '1,,•\.....c; •0 with the Florida Energy A �+de. •k + ciDD. ; ��ht .uYV I'frysO0 OWNER/ T: _A�`�-� ' /-' BUILDING OFFICIAL: DATE: �� �/ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2:1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/9/2018'4:20 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: Toll Brothers,Inc. Permit# OkS/?-0067 Project Address: 568 Timber Bridge Lane,Atlantic Beach,FL 32233 Lot 175 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuildins.ore. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6 Single-FL6506.4 Simpson Door Company Wood Door FL 14487.1 Therma-Tru Fiberglass/Wood Door N/A FL 5262.3 2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251 3. Sectional Clopay Building Products Section Ext.Door +20/-20 PSF FL15279.1/FL15279.3 4.Roll up 5.Automatic 6. Other B. WINDOWS 1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435 2.Horizontal slider PGT 5400 Vinyl Hor.Window +50/-50 FL 1844 3.Casement 4.Double hung 5. Fixed PGT 5400 Vinyl Fixed Window +50/-50 FL 5012 6.Awning 7.Pass-through 8.Projected 9.Mullion PGT Alum/Vinyl Mullions N/A FL 261 10.Wind Breaker 11. Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1 12. Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C.PANEL WALL 1.Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4 FL 12098.3; 12098.1; Nichiha Corp. Lap Siding and Shingles N/A 12875.1 2.Soffits/Ceilings James Hardie Building Products,Inc. Soffit Panels N/A FL 13265.1 Nichiha Corp. Soffit Panels N/A FL 12098.4 3.EIFS 4. Storefronts Kawneer Glass Windows Mitred Glass +30/-30 FL 10008.1 5.Curtain walls 6.Wall louvers 7.Glass block 8.Membrane 9.Greenhouse 10.Synthetic Stucco 11.Other D.ROOFING PRODUCTS 1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1 2.Underlayments Woodland Industries,Inc. Felt N/A FL 1814.12 Boral Roofing Roof Underlayment N/A FL 14317.1 3.Roofing fastners 4.Nonstructural metal roof Millennium Metals,Inc. Metal Roofing-M seam N/A FL 5211.3 R6 5.Built-up roofing 6.Modified bitumen 7.Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing 11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake N/A FL 13714.1 12.Roofing slate - 13.Liquid applied roofing 14.Cement-adhesive coats 15.Roof tile adhesive 16.Spray applied polyurethane roof 17.Other Pli-Deck Walking deck membrane :\ FL 12407.1 Category/Subcategory Manufacturer Product Description Limitation of Use State At Local# E. SHUTTERS 1.Accordion 2.Bahama 3.Storm panels Town and Country Industries Storm shutters N/A FL 11963 4.Colonial 5.Roll-up 6.Equipment 7.Other F. STRUCTURAL COMPONENTS 1.Wood connector/anchor Simpson Strong Tie Per engineering 2.Truss plates Alpine Engineered Truss plate conn. Per engineering 3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1 4.Railing 5.Coolers-freezers 6.Concrete admixtures 7.Material 8.Insulation forms 9.Plastics 10.Deck-roof 11.Wall 12. Sheds 13.Other G. SKYLIGHTS 1.Skylight Sun Tek FGC Skylite FL 2442 2.Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1 7/16"Zip Wall- Structural 1 OSB(roof and wall);manufacturered by Huber Engineered Woods 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector,a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. Audrey Regnier jejl / (Contractor Name) (Print Name) (Signature) Company Name: Toll Brothers,Inc. Mailing Address: 160 Cape May Avenue City: Ponte Vedra State: FL Zip Code: 32081 Telephone Number: 904 217-0739 Fax Number: Cell Phone Number: 904-405-8969 Email Address: aregnier@tollbrothers.com OFFICE COPY FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: Davenport Bonus 3026 Right N Builder Name: Toll Brothers Street: Lot 175 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach , FL, Permit Number: •• Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 3026 sq.ft. Cond.Volume: 29506 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: FORM R405-2017 : 1 Pa cfm 2 Pa cfm Tested ACH(50):*: 3 •Pa cfm • *Tested leakage must be less than or equal to the -4 Pa cfm required ACH(50)shown on Form R405-2017 for 5 Pa cfm this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation 6 Pa cfm system. R402.4:1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth In Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; -4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either ;,. " •D��SE S74?f • performance results demonstrate compliance individuals as defined in Section i ,._ O b;. with Florida Energy Code requirements in 553.993(5)or(7), Florida Statutes or , fr ,�••.,s individuals licensed as set forth in h for ' accordance with Section R402.4.1.2. �} o Section 489.105(3)(f), (g), or(i)or an • g r } approved third party.A written report of10-, a? the results of the test shall be signed * •... ; ,�+Y. SIGNATURE: by the third party conducting the test '. t'' 4t,./ and provided to the code official. `� C ..................5*' taA WB' ' PRINTED NAME: `'t�..:,.,....,.,,��.+ BUILDING OFFICIAL: DATE: DATE: 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 _� OFFICE COPY 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Davenport Bonus 3026 Right N Builder Name: Toll Brothers Street: Lot 175 Atlantic Beach CCPermit Office: Atlantic Beach • City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers .Jurisdiction: .261300 ' Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) - '1. New construction or existing New(From Plans) 9. WallTypes(3577.8 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 3397.80 ft2 _2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 180.00 ft2 3. Number of units,if multiple family '1 c.N/A R= ft2 •4. Number of Bedrooms 4 • d.N/A R= ft2 •10.Ceiling Types (2271.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1997.00 ft2 • 6. Conditioned floor area above grade(ft2) 3026 b.Under Attic(Vented) R=19.0 274.00 ft2 c.'N/A R= .ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(318.0 sqft.) Description Areaa.Sup:Attic,Ret:Attic,AN:Garage 6 414 a. U-Factor: Dbl,U=0.34 318.00 ft2 SHGC: SHGC=0.27 b. U-Factor: N/A _ft2 1 12.Cooling systems kBtu/hr Efficiency a.Central Unit -42.0 SEER:14.00 SHGC: c. U-Factor: N/A .ft2 SHGC: 13.Heating systems kBtu/hr Efficiency ' d. U-Factor N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.579 ft. 14.Hot water systems Area Weighted Average SHGC: 0.270 a.Natural Gas Tankless Cap: 1 gallons 8. Floor Types (3026.0 sqft.) Insulation Area EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 2272.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 691.00 ft2 None • c.other(see details) R= 63.00 ft215.Credits Pstat • Total Proposed Modified Loads: 73.61 • '�PASS S Glass/Floor Area: 0.105 Total Baseline Loads: 81.37 , I hereby certify that the plans and specifications covered by Review of the plans and f.��'`Q,'1{E.S ,'.i, this calculation are in compliance with the Florida Energy specifications covered by this a. �% .a�:.^ ..,0`; calculation indicates compliance ito1%i„ , 4� _- - a Code. p ' 's' �..,c" , with the Florida Energy Code. z F,,"rrrr i ,-.:,,-.1;,.: s„,,,,`a':O /� •.,�. PREPARED BY: i LDlE ryr75vim.,nBefore construction is completed z _ a DATE: d'/*--,''''-- 0-eve this building will be inspected for {,.__ compliance with Section 553.908 * .. :' Florida Statutes. ''+ ,);-.0014,- ��` ''' + I hereby certify that this .uilding,as designed,is in compliance ,'')' ' • ....�5'. with the Florida Energ r ode. / . '`t`C•°D W ' OWNER/A NT: _.A �'../ LBUILDING OFFICIAL: m�' DATE: ���'�1 ‘ / DATE: a 'I 7-20Ig' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1/9/20184:20 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: Davenport Bonus 3026 Right Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3026 Lot# Owner Name: Toll Brothers Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: - 0 Street: Lot 175 Atlantic Beach Permit Office: Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach , • Family Type: Single-family FL, New/Existing: New(From Plans) Comment: - CLIMATE • Design Temp Int Design Temp Heating Design Daily Temp . Design Location TMY Site 97.5% .2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 32 93 70 75 1281 49 Medium • BLOCKS Number Name Area Volume 1 Block/ 3026 29506 • SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished. Cooled Heated 1 Main 2272 22720 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 754 6786 No 1 1 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet / 1 Slab-On-Grade Edge Insulatlo Main 194 ft 0 .2272 ft2 ____ 0 0 1 2 Floor over Garage 2nd Floor 63 ft2 19 0 0 1 3 Floor Over Other Space 2nd Floor _ 691 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 7 1 Gable or Shed Composition shingles 2704 ft2 682 ft2 Medium 0.6 N 0.9 No 0 30.3 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC ✓ 1 Full attic Vented 300 2335 ft2 N N • 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING Viz # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 19 Blown 154 ft2 0.11 Wood 2 Under Attic(Vented) Main 38 Blown 1363 ft2 0.11 Wood 3 Under Attic(Vented) 2nd Floor 38 Blown 634 ft2 0.11 Wood •4 Under Attic(Vented) 2nd Floor '19 Blown 120 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below . . . . I Type Space R-Vabie Ft it Ft In AMA R-Value Frartinn Abcor Grarie% _ 1 N Exterior Frame-Wood Main 19 20 0 10 0 200.0 ft2 0 0.23 0.6 0 2 E Exterior Frame-Wood Main 19 77 0 10 0 770.0 ft2 0 0.23 0.6 0 3 SE Exterior Frame-Wood Main 19 11 .2 10 0 111:7 ft2 0 0.23 0.6 0 4 S Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.6 0 5 W Exterior Frame-Wood Main 19 77 0 10 0 770.01t2 0 0.23 0.6 0 6 N Garage Frame-Wood Main 13 20 0 9 0 180.0 ft2 0 0.23 0.01 0 ' . 7 SW Exterior Frame-Wood Main 19 6 2 10 0 61.71t2 0 0.23 0.6 0 8 N Exterior Frame-Wood .2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 9 E Exterior Frame-Wood .2nd Floor 19 20 3 .9 0 182.3 ft2 0 0.23 0.6 0 ; 10 S Exterior Frame-Wood .2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 11 W Exterior Frame-Wood 2nd Floor 19 20 3 9 0 182.3 ft2 0 0.23 0.6 0 • DOORS V' / # Ornt Door Type Space Storms U-Value Ft Width In FHeightln Area (/ t 1 N Insulated Main None 4 3 8 24 ft2 .2 N Wood Main None 4 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V / -# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.34 0.27 N 18.0 ft2 7 ft 4 in 1-ft 0 in Drapes/blinds Exterior 5 2 E .2 Vinyl Low-E Double Yes 0.34 .0.27 ' N 15.0 ft2 1 it 4 in 1 ft 0 in Drapes/blinds Exterior 5 • 3 E .2 Vinyl Low-E Double Yes 0.34 0.27 N 6.0112 1 ft 4 in 1-ft 0 In None Exterior 5 • 4 E 2 Vinyl Low-E:Double Yes 0.34 0.27 N 72.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 5 S 4 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft2 91t4 in 1 ft 0 in Drapes/blinds Exterior 5 • 6 S 4 Vinyl Low-E Double Yes 0.34 0.27 N 96.0112 1 ft 4 in 1 ft 0 in None Exterior 5 7 W 5 Vinyl Low-E Double Yes 0.34 0,27 N 20.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 8 E 9 Vinyl Low-E Double Yes 0.34 0.27 N 30.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 9 W 11 Vinyl Low-E Double Yes 0.34 0.27 N 15.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 I 10 W 11 Vinyl Low-E Double Yes 0.34 0.27 N 4.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 • 11 W 5 Vinyl Low-E Double Yes 0.34 0.27 N 6.0 ft2 1 ft 4 in •1 ft 0 in None Exterior 5 • 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 I FORM R405-2017 • ' GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation ✓ 1 444 ft2 444 ft2 54 ft 9 ft 0 INFILTRATION • # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 • 1 Wholehouse Proposed ACH(50) .000434 3442.4 188.98 355.41 .4111 7 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity Block Ducts f 1 Electric Heat Pump/ None HSPF:8.2 42 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:14 42 kBtu/hr 1260 cfm 0.76 1 sys#1 ,HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation .✓ 1 Natural Gas Tankless Exterior 0.8 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert 4 Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply-- —Return— Air CFM 25 CFM25 HVAC# / # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 414 ft2 Attic 117 ft2 Default Leakage Garage (Default) (Default) 1 1 • • 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 • TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ Jan H Feb [ ]]MarApr I ]May ri JunX]Jul [X]Au [X]Se [ ]Oct ]Nov DecHeating [X�Jan Feb l ]Mar iApr ]MaJunJulAugSeOct f X]Nov X Dec Venting [[ Jan Feb [X Mar [X Apr ]May Jun [ ]Jul l Aug ))SepX[ ]]Oct [X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours • Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) PM 78 80 78 78 78 78 78 78 80 80 80 78, Cooling(WEH) AM 78 78 78 78 78 - 78 78 78 • 78 78 78 - 78 8 78 Heating(WD) AM 66 68 68 68 68 68 68 8 68 68 68 68 68 68 6 66 Heating(WEH) PM 68 66 66 66 68 66 68 68 68 68•8 68 68 68 6 66 • 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index, the more efficient the home. Lot 175 Atlantic Beach CC, Atlantic Beach , FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 3397.80 ft2 b.Frame-Wood,Adjacent R=13.0 180.00 ft' 3. Number of units,If multiple family '1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=38.0 1997.00 ft2 6. Conditioned floor area(ft') 3026 b.Under Attic(Vented) R=19.0 274.00 ft' 2 7. Windows** Description Area c. R= ft a. U-Factor: Dbl,U=0.$4 318.00 ft' 11.Ducts �R ft2 a.Sup:Attic,Ret:Attic,AH:Garage 6 414 SHGC: SHGC=0.27 . b. U-Factor. N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 2.579 ft. Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14.Hot water systems a.Natural Gas Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2272.00 ftEF:0.8 b.Floor Over Other Space R=0.0 691.00 ft' c.other(see details) R= 63.00 ft' b. Conservation features None 15.Credits Pstat I certify that this home has ed h the orida Energy ciency e for ng Construction through the above penergytsav ng(features which will be installed ll (orBexce exceeded) r'�```o4Ito Sr,-... 0., in this home.before final inspection. Otherwise, a new.EPL Display Card will be completed ?w°".f. ,; •z s e`,..''`' based on installed Code mpliant features. i `n�,, ' -'d, O / / F s ;CJs Builder Signature: Date: a � � ftp�..N��� ;arAddress of New Home: K1, r,�(744...z.. a LA Cit /FL Zip: Y* •• . .'*0. // w6 ,, 3�.?..3 ° 'k-e............,•, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at • techsupport@energygauge.com or see the EnergyGauge web site at energygauge.corn for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 • Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Lot 175 Atlantic Beach CC Permit Number: Atlantic Beach ,FL, MANDATORY REQUIREMENTS See individual code sections.forfull details. SECTION R401 GENERAL R401:3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law • (Section 553.9085,Florida Statutes)requires the EPL display card to be Included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit.air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4:1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1:1 Installation.The components of the building thermal envelope as listed In Table R402.4.1.1 shall be installed in accordance with the manufacturer's Instructions and the criteria listed in Table R402:4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4:1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if Installed at the time of the test,shall be open. .4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6. Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. • R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5 • MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,Isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. • 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed • luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403:1 Controls. R403.1:1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or Individuals licensed as set forth in Section 489.105(3)(f),(g)or(I),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2:1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if Installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0:1 Inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: . 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building • thermal envelope. 2. Duct testing Is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy' 1/9/2018 4:20 PM EnergyGauge8 USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5 • MANDATORY REQUIREMENTS - (Continued) • R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature • setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy suppliedto the main burner(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. • R403.5.6.2:1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6:2 Ventilation air. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM (CFM) (CFM/WATT) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5 • ° MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. . Exceptions: • 1. Attached single-and multiple-family residential equipment sizing may be selected so that Its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. .2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7:1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7:1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. .2. A variable capacity system sized for optimum performance during base load periods Is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). R403;10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. • 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning-pilot lights. • 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatoryl)he energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS • R404:1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. • • • 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 5 of 5 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA • TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Davenport Bonus 3026 Right N Builder Name: Toll Brothers Street: Lot 175 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope.. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to • unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spares. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed In the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall • extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be Installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 1/9/2018 4:20 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Project Summary Date: Lot 175 ABCC ` ��' Entire House ��� ;�°�� � � By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.corn Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: The Davenport Bonus Desi•n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 96 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 21 °F Daily range M Relative humidity 50 Moisture difference 48 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 37474 Btuh Structure 23497 Btuh Ducts 4152 Btuh Ducts 4801 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 41626 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28298 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/2 Pressure/AVF 50 Pa/3505 cfm 'Structure 8016 Btuh Ducts 761 Btuh Central vent(0 cfm) 0 Btuh Heating0Cooling (none) Area(ftp 3026 3026 Equipment latent load 8777 Btuh Volume(ft3) 30046 30046 Air changes/hour 0.68 0.40 Equipment Total Load (Sen+Lat) 37075 Btuh Equiv.AVF (cfm) 338 203 Req.total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0420000A0 Cond CH14NB0420000A0 AHRI ref 9162578 Coil FB4CNP042L AHRI ref 9162578 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 30 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.029 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.76 Capacity balance point=33°F Backup: Input= 12 kW, Output=41626 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w rightsoft` 2018-Jan-09 15:47:09 r Comfort Builder by Wrightsoft 18.0.08 RSU03444 Page 1 ACC*. ...s\Davenport Bonus 3026 Right-Lot 175 ABCC.rup Calc=MJ8 Front Door faces: N N • First Floor 3"Fan apx4 8 .y 4,8 6 x10 We 3"Fan 10" 6, 10x6 %\` 6" KM 14 w +����r Master / i12 .--4., Garage / 12" axe M.Bath 4x ® 4, 4. s x 10 Laundry.; 16x16 MWIC 10x10 18" 14' 8" up ' 10x10 ClSt 16x 16 O 12"• I Great 6x127„ i 6x10 12"14"'"'"'i� Foyer ■ 1] Dining Kitchen / IF J x 12 12 10x6 12x12 18x24 11 6" 8" 18" 777 6x12 pp 6: 12 7• L 7" ® Bed3 ' 8 x 4 6x12 6ed2 Nook 4„ 6x12 7" Bath 2 ,.__.3"Fan P) \i O o Job#: Lot 175 ABCCMcGowan's Heating & Air Conditionin. scale: : 128 Performed by Saldie Guintivano for: Page 1 Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,Fl 32256 18.0.08 RSU03444 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2018-Jan-09 15:48:49 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com saldie@mcgowansac.com ...us 3026 Right-Lot 175 ABCC.rup www.tollbrothers.corn smerten@tollbrothersinc.corn iN 2nd 3"Fan lI ath 3 6x10 bed 4 61 14 x6 8- 12 x 12 10^ EIN � 16x 16 12x6 12^ 12" loft 1 :0 Job #: Lot 175 ABCC 1 : 128 Performed by Saldie Guintivano for: McGowan's Heating & Air Conditionin. Page2 Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,Fl 32256 18.0.08 RSU03444 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2018-Jan-09 15:48:49 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com saldie@mcgowansac.com ..us 3026 Right-Lot 175 ABCC.rup www.tollbrothers corn smerten@tollbrothersinc corn Manual S Compliance Report Job: Lot 175 ABCC Date: iffEntire House By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.corn Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Emil: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 95.8°F Sensible gain: 28298 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.4°F Latent gain: 8777 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 37075 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Sensible capacity: 28194 Btuh 100%of load Latent capacity: 8778 Btuh 100%of load Total capacity: 36972 Btuh 100%of load SHR: 76% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: .41626 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Output capacity: 32370 Btuh 78%of load Capacity balance: 33 °F Supplemental heat required: 9256 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 12.2 kW 100%of load Temp. rise: 61 °F Meets all requirements of ACCA Manual S. wr4yhtsoft'" 2018-Jan-09 15:47:09 "=- Comfort Builder by Wrightsoft 18.0.08 RSU03444 Page 1 AC ...s\Davenport Bonus 3026 Right-Lot 175 ABCC.rup Calc=MJ8 Front Door faces:fl Duct System Summary Joe: Lot 175 ABCC Da Entire House v into-4cr � + B Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.250/0.140 in H2O 0.250/0.140 in H2O Lowest friction rate 0.081 in/100ft 0.081 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length(TEL) 483 ft Supply Branch Detail Table Design Htg Clg Design Diann H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath 2 h 1191 35 27 0.133 4.0 Ox 0 VIFx 38.2 150.0 st2 Bed 2 h 5542 163 98 0.130 7.0 Ox 0 VIFx 43.0 150.0 st2 Bed 3 c 1354 48 59 0.134 6.0 Ox 0 VIFx 41.7 145.0 st2 Dining c 2302 78 100 0.081 7.0 Ox 0 VIFx 70.0 240.0 st6 Foyer h 2424 71 63 0.137 6.0 Ox 0 VIFx 37.1 145.0 st2 Great-A h 4587 135 111 0.088 7.0 Ox 0 VIFx 50.4 235.0 st6 Kitchen c 2066 47 89 0.085 7.0 Ox 0 VIFx 56.1 240.0 st6 Laundry h 451 13 12 0.149 4.0 Ox 0 VIFx 18.5 150.0 st3 M enc c 19 0 1 0.111 4.0 Ox 0 VIFx 29.5 195.0 st5 M.Bath c 1804 69 78 0.141 - 6.0 Ox 0 VIFx 17.5 160.0 st3 Master h 2022 59 50 0.119 6.0 Ox 0 VIFx 25.5 185.0 st5 Master-A h 2022 59 50 0.117 6.0 Ox 0 VIFx 28.0 185.0 st5 Nook h 4241 125 114 0.086 7.0 Ox 0 VIFx 54.6 235.0 st6 bath 3 h 1385 41 39 0.115 6.0 Ox 0 VIFx 58.3 160.0 st4 bed 4 c 2370 77 103 0.118 8.0 Ox 0 VIFx 51.9 160.0 st4 loft c 2415 89 105 0.123 7.0 Ox 0 VIFx 43.6 160.0 st4 loft-A c 2415 89 105 0.120 7.0 Ox 0 VIFx 49.3 160.0 st4 we h 827 24 24 0.142 4.0 Ox 0 VIFx 21.0 155.0 st3 {"1- wrightsoft' 2018-Jan-0915:47:09 v.. - -... -....„.. ,.,_, Comfort Builder by Wnghlsoft 18.0.08 RSU03444 Page 1 ACS'k ...s\Davenport Bonus 3026 Right-Lot 175 ABCC.rup Calc=MJ8 Front Door faces:N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 297 351 0.115 446 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 297 351 0.115 446 12.0 0 x 0 VinIFIx st2 Peak AVF 318 247 0.130 583 10.0 0 x 0 VinlFlx st3 Peak AVF 610 628 0.081 587 14.0 0 x 0 VinIFIx st6 Peak AVF 385 414 0.081 527 12.0 0 x 0 VinIFIx st5 st5 Peak AVF 504 514 0.081 655 12.0 0 x 0 VinIFIx st3 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rsb4 Ox 0 118 142 153.5 0.091 260 10.0 Ox 0 VIFx rt4 rb4 Ox 0 243 219 137.1 0.102 695 8.0 Ox 0 VIFx rt2 rb3 Ox 0 163 98 140.6 0.099 369 9.0 Ox 0 VIFx rt2 rb5 Ox 0 179 209 124.4 0.112 473 9.0 Ox 0 VIFx rt4 rb1 Ox 0 522 557 173.1 0.081 521 14.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt4 Peak AVF 297 351 0.091 446 12.0 0 x 0 VinIFIx rt3 rt2 Peak AVF 928 874 0.081 525 18.0 0 x 0 VinIFIx rt1 rt3 Peak AVF 297 351 0.091 446 12.0 0 x 0 VinlFlx rt1 rt1 Peak AVF 1225 1225 0.081 693 18.0 0 x 0 VinIFIx wri htsoft' 2018-Jan-09 15:47:09 ' - .. Comfort Builder by Wrightsoft 18.0.08 RSU03444 Page 2 1C ...s\Davenport Bonus 3026 Right-Lot 175 ABCC.rup Calc=MJ8 Front Door faces: N OFFICE COPY CBUCK Engineering Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report "M-Seam" Metal Roof Assembly Manufacturer: Millennium Metals, Inc. 10200 Eastport Road Jacksonville, FL 32218 (877) 358-7663 for Florida Product Approval # FL 5211.3 R7 Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: "M-Seam" Material: Steel Panel Thickness: 26 gauge, (Minimum) Panel Width: 16" Facsimile of digital copy signed by Support: Wood Deck James L.Buckner,P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G15-23. 00111111/0,,/ Prepared by: �Q ,• \CENSE �� James L. Buckner, P.E., SECB ' *.1 No 31242 Florida Professional Engineer # 31242 �� * Lu Florida Evaluation ANE ID: 1916 % .(�'. STATE OF � iz� ' �S. •.!cCOR •'!9.t.• ('jam`. Report No. 17-196-M-S6W-ER ''�S/ONAI- 0\\N (Revises 15-104-M-56W-ER) �� \` Date: 10/ 16/ 17 Contents: Evaluation Report Pages 1—7 2017.10.19 20:13:36-04'00' CBUCK,Inc.—Palm Beach County, Florida Phone:(561)491-9927• Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net Main Office: 1374 Community Drive,Jupiter, Florida 33458 FL#: FL 5211.3-R7 ! i f Date: 10/16/17 CBUCK E g n 1 in Report No.: 7 M S6W ER Page 2of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Millennium Metals, Inc. Product Name: "M-Seam" Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005(1) (d) Product/System "M-Seam" Description: 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials&standards: Evaluated: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation(Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32 (min.) or 19/32"or greater plywood, • or Wood plank(min.specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: Refer to Table"A" (Refer to"Table A" attachment details herein) FL#: FL 5211.3-R7 CBUCK Date: 10/16/17 n ` net r Report No.: 7 M S6W ER Page 3of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06—Test for Uplift Resistance of Roof Assemblies • UL 1897-12—Uplift test for roof covering systems Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 6th Edition(2017). • The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-12 standard version adopted by the Florida Building Code 6th Edition (2017). Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 6th Edition (2017),Section 1504.3.2. Evaluation Report Scope: This product evaluation is limited to compliance with the structural requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and •Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation,specifications and installation method(s)which include"Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20- 3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval". •Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for"project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. •This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC)61G20-3.This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure,site specific or permit design. •All metal components and fasteners shall be corrosion resistant in accordance with applicable sections of FBC, including but limited to Sections 1504.3.2, 1506.6 and 1507.4.4. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3,and is therefore not included in this evaluation. •This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade& Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization#: QUA 1824). FL#: FL 5211.3-R7 Date: 10/16/17 \ UD Engineering Page rt No.:47of 7 M-196 -ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Components/Materials Roof Panel: (by Manufacturer): Product Identification: M-Seam Material: Steel Thickness: 26 gauge Minimum Panel Width: 16"(max.)Coverage Rib Height: 1" Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: • ASTM A792 coated,or • ASTM A653 G90 galvanized steel Fastener: Type: Pancake-Head Wood Screw Size: #10(x length to meet min.penetration through deck) Penetration Through: 3/16" min.through wood deck Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.4 Components/Materials Underlayment: (by Others): Material and application shall be in compliance with FBC Section 1507.1.1 and in accordance with applicable code sections and manufacturer's recommendations. Insulation(Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf(lbs/ft3) min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL#: FL 5211.3-R7 Date: 10/ 16/17 CB CK Enq ePrin rt No•: 7M-s6w ER Page 5of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation: Installation Method: (Refer to drawings on Pages 6-7 of this report.) • Fastener spacing: Refer to Table"A"Below (along the length of the panel) • Rib Interlock: Snap Lock (Panel ribs shall be fully engaged to form an integral interlock.) • Minimum fastener penetration thru bottom of support,3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE"A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32"or 19/32" 15/32"or 19/32" Fastener Spacing: 8" 4" *Allowable design pressure for allowable stress design(ASD)with a margin of safety of 2 to 1. Install the "M-Seam" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-94& UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC(FBC Organization#TST ID: 1527) Report#: 0232-0508-05, Report Date:6/29/05,Specimens#1-3 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) Millennium Metals Licensee#423 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 4. Certification of Independence By James L. Buckner, P.E.@ CBUCK Engineering (FBC Organization#ANE 1916) FL#: FL 5211.3-R7 �t f-1 f� f'-1 Date: 10/ 16/ 17 CBUCK Engineer in Report No.:67of 7 M-196 -ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Profile Drawings 1" 15 Coverage _L..li i Opti Striations 314° Type:Pencil Rib a Striated Typical Panel Profile View (Not To Scale) 16"o.c. Integral Snap Lock rag" #10 Fake-Head Screw .._4-\_ __. 3/16"rrin. penetration thru deck Typical Assembly Profile View (Not To Scale) FL#: FL 5211.3-R7 t �I Date: 10/ 16/ 17 CK Engin r ng Page rt No.:770 f 7 M-s6w-ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Fastener. #10 Female-Head Scr- "M-Segni'Roof Panel --------- -- ;q / / /7') / 8"o.c Typical L support: Insulation: -15132'or 19J32"COX Plywood Deck,or (Optional)3"mac or 25 psi min. -V\bod plank Typical Assembly Profile View (Not To Scale) TABLE"A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32"or 19/32" 15/32"or 19/32" Fastener Spacing: 8" 4" *Allowable design pressure for allowable stress design(ASD)with a margin of safety of 2 to 1. OFFICE COP' PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft') 3O 6 Non-Habitable Space (ft") LAND INFORMATION: Zoning District /i(SGL Flood Zone )4 Minimum FFE C/I . 9O') PPoe. 02-0°0 BUILDING INFORMATION: Construction Type t i3 Occupancy Group S nS/< ran-,, Number of Stories . Max Occupancy Load Fire Sprinklers Required /Irl/ CONDITIONS/ COMMENTS: Rev. 2.7.2018