Loading...
1769 ATLANTIC BEACH DR - TRUSSES ' Ossi Development '41- Site rSite Information 036-01 Atlantic Beach Country Club(FL-Duval) OFFICE COPY 6111)Structural Engineer of Record Derek B. Murray PE No. 71457 4745 Sutton Park Court,Suite 402 u eHo use Jacksonville, FL 32224 WIND LOADING (Cd=1.6) ROOF LOADING (Cd=1.25) FLOOR LOADING (Cd=1.00) MWFRS TCLL 20 psf TOLL 40 psf 130 MPH (3 second gust)\ASCE 7-10 TCDL 07 psf TCDL 17 psf Enclosed Structure(0.18) BCLL 00 psf+ NCLL 10 psf BOLL 00 psf Exposure C BCDL 05 psf BCDL 05 psf Occupancy Category II(Res) FBC2014 Residential/TPI-2007 Design Program:ITW VIEW v17.00.000 This Package inlcudes 101 truss designs with individual date of design NO JOB ID TRS ID DATE NO JOB ID TRS ID DATE NO JOB ID TRS ID DATE 1 71613 F01 9/25/2017 31 71613 HJ07B 9/25/2017 61 71613 J23 9/25/2017 2 71613 F02 9/25/2017 32 71613 HJ08 9/25/2017 62 71613 J24 9/25/2017 3 71613 F03 9/25/2017 33 71613 HJ09 9/25/2017 63 71613 TO1 9/25/2017 4 71613 FO3A 9/25/2017 34 71613 HJ10 9/25/2017 64 71613 I 102 9/25/2017 5 71613 F04 9/25/2017 35 71613 HJ12 9/25/2017 65 71613 103 9/25/2017 6 71613 F05 9/25/2017 36 71613 J01 9/25/2017 66 71613 104 9/25/2017 7 71613 FO5A 9/25/2017 37 71613 J02 9/25/2017 67 71613 105 9/25/2017 '8 71613 F06 9/25/2017 38 71613 J03 9/25/2017 68 71613 106 9/25/2017 9 71613 F07 9/25/2017 39 71613 103A 9/25/2017 69 71613 T07 9/25/2017 10 71613 F08 9/25/2017 40 71613 J04 9/25/2017 70 71613 T08 9/25/2017 11 71613 FG01 9/25/2017 41 71613 J05 9/25/2017 71 71613 109 9/25/2017 12 71613 FG02 9/25/2017 42 71613 JO5A 9/25/2017 72 71613 T10 9/25/2017 13 71613 FG03 9/25/2017 43 71613 JO5B 9/25/2017 73 71613 T11 9/25/2017 14 71613 FG04 9/25/2017 44 71613 J07 9/25/2017 74 71613 T12 9/25/2017 15 71613 FG05 9/25/2017 45 71613 JO7B 9/25/2017 75 71613 113 9/25/2017 16 71613 FG06 9/25/2017 46 71613 J07C 9/25/2017 76 71613 114 9/25/2017 17 71613 FG07 9/25/2017 47 71613 J08 9/25/2017 77 71613 T16 9/25/2017 18 71613 FG08 9/25/2017 48 71613 J10 9/25/2017 78 71613 T17 9/25/2017 19 71613 FG09 9/25/2017 49 71613 J11 9/25/2017 79 71613 118 9/25/2017 20 71613 FG10 9/25/2017 50 71613 J12 9/25/2017 80 71613 T19 9/25/2017 21 71613 FG11 9/25/2017 51 71613 J13 9/25/2017 81 71613 T20 9/25/2017 22 71613 FGE01 9/25/2017 52 71613 J14 9/25/2017 82 71613 T21 9/25/2017 23 71613 FGE02 9/25/2017 53 71613 J15 9/25/2017 83 71613 T22 9/25/2017 24 71613 FT01 9/25/2017 54 71613 J16 9/25/2017 84 71613 T23 9/25/2017 25 71613 FT02 9/25/2017 55 71613 J17 9/25/2017 85 71613 T24 9/25/2017 26 71613 FT03 9/25/2017 56 71613 J18 9/25/2017 86 71613 T25 9/25/2017 27 71613 HJ02 9/25/2017 57 71613 J19 9/25/2017 87 71613 T26 9/25/2017 28 71613 HJO4 9/25/2017 58 71613 J20 9/25/2017 88 71613 %%%1111 'I i 9/25/2017 I 29 71613 HJO7 9/25/2017 59 71613 J21 9/25/2017 89 716 S' ,)K M' �• 11hp 9/25/2017 30 71613 HJO7A 9/25/2017 60 71613 J22 9/25/2017 g0 : �• • CiE 'Q� X1/25/2017 • i • Apex Technology is a ficticious name owned by Jax Apex Technology,Inc.,a Florida Corporation. Florida,' O 7 t 4 .7 lq*/\ Engineer Business No.7547-4745 Sutton Park Court,Suite 402 Jacksonville,FL 32224(904)821- ': k * .* slnn The seal on this index sheet indicates acceptance of professional engineering responsibility solely for tbj Truss Design Drawings listed above and attached.The suitability and use of each drawing for any • �• particualr building is the responsibility of the Building Designer,per ANSI/TPI 1-2002 Section 2; • • 14/;y APEX • With my seal affixed to this sheet,I hereby certify that this serves as an index sheet in conformance with s�-� • R '°.'e� �` Rule 61G15-23.002(2)and 61G15-31.003 of the Florida Board of Professional Engineers 'I S '• ,.•1•••43 N II111 i 112V• Ossi Development Site Information 036-01 Atlantic Beach Country Club(FL-Duval) igOrvN"-) Structural Engineer of Record H Derek B.Murray PE No. 71457 4745 Sutton Park Court,Suite 402 nueHouse Jacksonville, FL 32224 WIND LOADING (Cd=1.6) ROOF LOADING (Cd=1.25) FLOOR LOADING (Cd=1.00) MWFRS TCLL 20 psf TCLL 40 psf 130 MPH (3 second gust)\ASCE 7-10 TCDL 07 psf TCDL 17 psf Enclosed Structure(0.18) BCLL 00 psf+ NCLL 10 psf BCLL 00 psf Exposure C BCDL 05 psf BCDL 05 psf Occupancy Category II (Res) FBC2014 Residential/TPI-2007 Design Program: ITW VIEW v17.00.000 This Package inlcudes 101 truss designs with individual date of design NO JOB ID TRS ID DATE NO I JOB ID TRS ID DATE NO JOB ID [IRS ID DATE 91 71613 T30 9/25/2017 92 71613 T31 9/25/2017 . 93 71613 T32 9/25/2017 94 71613 T33 9/25/2017 95 71613 T34 9/25/2017 96 71613 T35 9/25/2017 97 71613 T36 9/25/2017 98 71613 T36A 9/25/2017 99 71613 737 9/25/2017 100 71613 T38 9/25/2017 101 71613 T39 9/25/2017 Apex Technology is a ficticious name owned by Jax Apex Technology,Inc.,a Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402 Jacksonville,FL 32224(904)821- 101111r F,,nn The seal on this index sheet indicates acceptance of professional engineering responsibility solely for the Truss Design Drawings listed above and attached.The suitability and use of each drawing for any particualr building is the responsibility of the Building Designer,per ANSI/TPI 1-2002 Section 2 APE With my seal affixed to this sheet,I hereby certify that this serves as an index sheet in conformance with Rule 61015.23.002(2)and 6101531.003 of the Florida Board of Professional Engineers 9/25/2017 Job#71613 BEARING INFORMATION WOODTRUSS QTY SPAN DESCRIPTION BRG# REACTION UPLIFT 1 14'09"08 FG01 HIPM 4.00/12 Pitch 2-Ply 1 1806.46 0.00 2 2997.39 0.00 1 13'11"00 FG02 COMN 4.00/12 Pitch 3-Ply 1 6152.19 0.00 2 8776.76 0.00 1 20'06"00 FG03 FLAT 0.00/12 Pitch 3-Ply 1 5317.85 0.00 2 5863.72 0.00 1 22'09"00 F004 FLAT 0.00/12 Pitch 2-Ply 1 8996.91 0.00 2 2041.45 0.00 1 22'06"08 FG05 FLAT 0.00/12 Pitch 2-Ply 1 9159.24 0.00 2 2057.25 0.00 1 11'05"00 FG06 FLAT 0.00/12 Pitch 3-Ply 1 7617.37 0.00 2 7821.33 0.00 1 12'11"08 FG07 COMN 4.00/12 Pitch 2-Ply 1 1605.42 0.00 2 2291.19 0.00 1 11'04"02 FG08 MONO 0.00/12 Pitch 2-Ply 1 3614.13 0.00 2 4778.21 0.00 1 16'09"00 FG09 FLAT 0.00/12 Pitch 3-Ply 1 6918.50 0.00 2 685.58 0.00 1 20'05"00 FG10 COMN 4.00/12 Pitch 3-Ply 1 3083.22 0.00 2 2768.23 0.00 1 20'05"00 FG11 COMN 4.00/12 Pitch 3-Ply 1 2989.63 0.00 2 3419.49 0.00 10 12'11"08 FT01 COMN 4.00/12 Pitch 1-Ply 1 1285.95 0.00 2 1002.95 0.00 4 20'05"00 FT02 COMN 4.00/12 Pitch 1 -Ply 1 2352.27 0.00 2 1452.19 0.00 1 20'05"00 FT03 COMN 4.00/12 Pitch 2-Ply 1 3262.86 0.00 2 1643.60 0.00 2 02'06"05 HJO2 HIP_JACK 4.24/12 Pitch 1 -Ply 1 277.01 139.00 2 63.19 12.00 3 34.87 25.00 1 05'06"06 HJO4 HIP_JACK 4.24/12 Pitch 1-Ply 1 177.26 162.00 2 71.51 14.00 3 77.53 79.00 4 09'09"05 HJO7 HIP_JACK 4.24/12 Pitch 1 -Ply 1 272.92 250.00 2 283.52 121.00 3 64.52 50.00 1 09'09"05 HJO7A HIP_JACK 4.24/12 Pitch 1 -Ply 1 290.70 261.00 2 302.65 135.00 3 66.56 52.00 1 09'09"05 HJO7B HIP_JACK 4.24/12 Pitch 1 -Ply 1 276.21 253.00 2 289.16 128.00 3 67.51 52.00 2 02'08"07 HJO8 HIP_JACK 4.24/12 Pitch 1-Ply 1 278.29 136.00 2 38.11 10.00 3 27.02 23.00 3 09'09"05 HJO9 HIP_JACK 2.83/12 Pitch 1 -Ply 1 266.46 180.00 2 281.82 73.00 3 56.00 27.00 Page 1 of 5 Job#71613 BEARING INFORMATION QTY ,SPANDESCRIPTION BRG# REACTION UPLIFT 1 09'09"05 HJ10 HIP_JACK 2.83/12 Pitch 1 -Ply 1 268.98 218.00 2 264.06 73.00 3 56.70 26.00 2 09'09"05 HJ12 HIP_JACK 2.83/12 Pitch 1 -Ply 1 232.39 205.00 2 728.83 160.00 3 -240.78 0.00 4 -102.72 0.00 14 01'00"00 J01 JACK 6.00/12 Pitch 1 -Ply 1 219.07 102.00 2 62.15 18.00 3 147.51 52.00 2 0110"08 J02 EJACK 6.00/12 Pitch 1 -Ply 1 200.90 73.00 2 22.11 8.00 3 21.70 19.00 13 03'00"00 J03 JACK 6.00/12 Pitch 1 -Ply 1 219.78 85.00 2 36.90 1.00 3 54.74 48.00 1 03'00"00 J03A JACK 6.00/12 Pitch 1 -Ply 1 98.48 24.00 2 42.46 4.00 3 73.08 59.00 2 04'00"00 J04 EJACK 6.00/12 Pitch 1 -Ply 1 245.41 57.00 2 52.05 0.00 3 84.47 40.00 10 05'00"00 J05 JACK 6.00/12 Pitch 1 -Ply 1 274.00 98.00 2 66.89 0.00 3 112.02 94.00 1 05'00"00 J05A JACK 6.00/12 Pitch 1 -Ply 1 164.14 43.00 2 71.07 5.00 3 122.89 101.00 1 04'10"08 J05B JACK 6.00/12 Pitch 1 -Ply 1 160.03 41.00 2 69.62 3.00 3 121.21 101.00 16 07'00"00 J07 EJACK 6.00/12 Pitch 1 -Ply 1 334.89 70.00 2 96.15 0.00 3 164.57 100.00 4 06'10"08 J07B EJACK 6.00/12 Pitch 1 -Ply 1 223.63 35.00 2 97.52 0.00 3 170.25 102.00 1 07'00"00 J07C MONO 6.00/12 Pitch 1 -Ply 1 476.86 211.00 2 506.96 248.00 5 02'00"00 J08 EJACK 6.00/12 Pitch 1-Ply 1 201.91 83.00 2 21.08 7.00 3 20.51 22.00 1 03'00"00 J10 COMN 6.00/12 Pitch 1 -Ply 1 754.13 258.00 2 430.33 171.00 1 03'00"00 J11 COMN 6.00/12 Pitch 1 -Ply 1 614.96 214.00 2 364.48 150.00 1 04'00"00 J12 MONO 6.00/12 Pitch 1 -Ply 1 498.88 166.00 2 485.04 160.00 6 01'00"00 J13 JACK 4.00/12 Pitch 1 -Ply 1 218.36 109.00 2 61.02 19.00 3 122.44 41.00 Page 2 of 5 Job#71613 BEARING INFORMATION QTY SPAN DESCRIPTION BRG# REACTION UPLIFT 6 03'00"00 J14 JACK 4.00/12 Pitch 1 -Ply 1 217.91 74.00 2 35.52 1.00 3 52.45 30.00 6 05'00"00 J15 JACK 4.00/12 Pitch 1 -Ply 1 271.20 78.00 2 65.44 0.00 3 108.42 59.00 9 07'00"00 J16 EJACK 4.00/12 Pitch 1 -Ply 1 331.17 93.00 2 94.45 0.00 3 160.16 86.00 6 01'00"00 J17 JACK 4.00/12 Pitch 1 -Ply 1 232.24 129.00 2 70.83 21.00 3 179.08 60.00 6 03'00"00 J18 JACK 4.00/12 Pitch 1 -Ply 1 226.17 78.00 2 33.80 2.00 3 47.46 29.00 6 05'00"00 J19 JACK 4.00/12 Pitch 1 -Ply 1 277.14 80.00 2 63.91 0.00 3 105.24 58.00 4 07'00"00 J20 EJACK 4.00/12 Pitch 1 -Ply 1 336.28 95.00 2 93.02 0.00 3 157.57 85.00 10 05'08"00 J21 MONO 4.00/12 Pitch 1 -Ply 1 290.80 73.00 2 164.36 34.00 5 07'00"00 J22 EJACK 4.00/12 Pitch 1 -Ply 1 284.83 75.00 2 555.69 215.00 3 -143.16 60.00 4 -228.08 103.00 5 03'06"08 J23 MONO 4.00/12 Pitch 1 -Ply 1 231.01 73.00 2 86.54 19.00 4 05'08"08 J24 MONO 4.00/12 Pitch 1 -Ply 1 457.85 199.00 2 0.00 1.00 1 28'01"00 T01 COMN 6.00/12 Pitch 1 -Ply 1 2082.94 892.00 2 1999.77 869.00 1 30'01"00 T02 COMN 6.00/12 Pitch 1 -Ply 1 1599.00 746.00 2 1825.18 813.00 1 28'01"00 T03 COMN 6.00/12 Pitch 1 -Ply 1 925.99 268.00 2 917.75 413.00 1 30'01"00 T04 COMN 6.00/12 Pitch 1 -Ply 1 1488.30 712.00 2 1005.84 497.00 1 30'01"00 T05 COMN 6.00/12 Pitch 1 -Ply 1 1079.61 321.00 2 984.20 290.00 1 30'01"00 T06 COMN 6.00/12 Pitch 1-Ply 1 1310.55 338.00 2 911.61 234.00 1 30'01"00 T07 COMN 6.00/12 Pitch 1 -Ply 1 1311.95 338.00 2 913.54 234.00 1 30'01"00 T08 COMN 6.00/12 Pitch 1 -Ply 1 1311.95 321.00 2 913.54 171.00 1 30'01"00 109 COMN 6.00/12 Pitch 1 -Ply 1 1304.30 334.00 2 919.78 170.00 1 30'01"00 T10 COMN 6.00/12 Pitch 1 -Ply 1 1304.30 358.00 2 919.78 173.00 Page 3 of 5 Job#71613 BEARING INFORMATION QTY SPAN DESCRIPTION BRG# REACTION UPLIFT 1 30'01"00 T11 COMN 6.00/12 Pitch 1 -Ply 1 1253.34 355.00 2 836.40 245.00 1 30'01"00 T12 COMN 6.00/12 Pitch 1 -Ply 1 1076.29 323.00 2 1076.29 325.00 1 20'09"00 T13 COMN 6.00/12 Pitch 1 -Ply 1 720.98 202.00 2 721.31 202.00 1 20'09"00 T14 HIPS 6.00/12 Pitch 1 -Ply 1 1570.24 684.00 2 1570.24 684.00 1 25'01"00 T16 COMN 6.00/12 Pitch 2-Ply 1 4970.84 2044.00 2 6825.81 2208.00 1 25'01"00 T17 SPEC 6.00/12 Pitch 1 -Ply 1 912.17 272.00 2 912.18 272.00 1 25'01"00 T18 HIPS 6.00/12 Pitch 1 -Ply 1 912.17 276.00 2 912.18 276.00 1 25'01"00 T19 HIPS 6.00/12 Pitch 1 -Ply 1 2014.25 878.00 2 2004.32 871.00 1 10'05"00 T20 COMN 6.00/12 Pitch 1 -Ply 1 821.71 264.00 2 994.74 280.00 1 07'07"00 121 HIPS 0.00/12 Pitch 1 -Ply 1 296.63 149.00 2 831.17 387.00 1 13'08"00 T22 HIPM 4.00/12 Pitch 1 -Ply 1 926.93 306.00 2 1186.71 373.00 1 13'08"00 T23 HIPM 4.00/12 Pitch 1 -Ply 1 541.31 162.00 2 431.91 151.00 1 13'08"00 T24 HIPM 4.00/12 Pitch 1 -Ply 1 541.31 156.00 2 431.91 156.00 1 13'08"00 T25 HIPM 4.00/12 Pitch 1 -Ply 1 921.33 306.00 2 1159.20 365.00 1 13'08"00 T26 HIPM 4.00/12 Pitch 1 -Ply 1 545.51 164.00 2 427.70 150.00 1 13'08"00 T27 HIPM 4.00/12 Pitch 1 -Ply 1 545.51 158.00 2 427.70 155.00 1 13'08"00 T28 HIPM 4.00/12 Pitch 1 -Ply 1 545.58 150.00 2 430.44 145.00 1 20'05"00 T29 HIPS 4.00/12 Pitch 1 -Ply 1 753.18 242.00 2 657.15 208.00 1 20'05"00 T30 HIPS 4.00/12 Pitch 1 -Ply 1 1623.67 523.00 2 1527.64 479.00 4 12'06"08 T31 MONO 4.00/12 Pitch 1 -Ply 1 505.42 86.00 2 394.95 79.00 1 21'02"00 T32 HIPM 4.00/12 Pitch 1 -Ply 1 -1221.05 116.00 2 676.83 165.00 1 21'02"00 T33 HIPM 4.00/12 Pitch 1 -Ply 1 782.04 120.00 2 676.83 178.00 1 21'02"00 T34 HIPM 4.00/12 Pitch 1 -Ply 1 782.04 144.00 2 676.83 189.00 1 21'02"00 T35 HIPM 4.00/12 Pitch 1 -Ply 1 782.04 159.00 2 676.83 198.00 1 21'02"00 T36 SPEC 4.00/12 Pitch 1 -Ply 1 782.04 148.00 2 676.83 165.00 Page 4 of 5 Job#71613 BEARING INFORMATION 1 QTY SPAN I DESCRIPTION I BRG# REACTION UPLIFT 1 21'02"00 T36A SPEC 4.00/12 Pitch 1 -Ply 1 782.04 154.00 2 676.83 184.00 2 21'05"00 T37 COMN 4.00/12 Pitch 1 -Ply 1 785.36 251.00 2 689.70 217.00 1 21'05"00 T38 HIPS 4.00/12 Pitch 1 -Ply 1 785.36 252.00 2 689.70 218.00 1 21'05"00 T39 HIPS 4.00/12 Pitch 1 -Ply 1 525.88 48.00 2 -618.68 597.00 3 268.66 380.00 4 193.42 103.00 WOODFLOOR I QTY SPAN DESCRIPTION i BRG# REACTION UPLIFT 3 20'06"00 F01 SY42 0.00/12 Pitch 1 -Ply 1 1255.44 0.00 2 1272.31 0.00 1 20'06"00 F02 SY42 0.00/12 Pitch 1 -Ply 1 1254.14 0.00 2 1259.36 0.00 2 22'09"00 F03 SY42 0.00/12 Pitch 1 -Ply 1 2873.81 0.00 2 1220.94 0.00 1 22'09"00 FO3A SY42 0.00/12 Pitch 1 -Ply 1 3330.30 0.00 2 1202.41 0.00 5 18'02"00 F04 SY42 0.00/12 Pitch 1-Ply 1 1126.33 0.00 2 1126.33 0.00 2 22'09"08 F05 SY42 0.00/12 Pitch 1 -Ply 1 2865.42 0.00 2 1223.81 0.00 1 22'09"08 FO5A SY42 0.00/12 Pitch 1-Ply 1 3454.64 0.00 2 1201.04 0.00 2 22'05"08 F06 SY42 0.00/12 Pitch 1 -Ply 1 1486.82 0.00 2 1780.49 0.00 2 22'05"08 F07 SY42 0.00/12 Pitch 1 -Ply 1 1602.64 0.00 2 1664.67 0.00 1 16'09"00 F08 SY42 0.00/12 Pitch 1 -Ply 1 2344.77 0.00 2 847.12 0.00 1 08'00"00 FGE01 SY42GABL 0.00/12 Pitch 1-Ply 1 963.50 0.00 1 02'00"00 FGE02 SY42GABL 0.00/12 Pitch 1 -Ply 1 219.50 0.00 Total of Trusses 254 Maximun Height 08'00"10 Page 5 of 5 1. PERMANENT BRACING IS ALWAYS REQUIRED AND MUST BE PROVIDED BY THE BUILDING DESIGNER OR ENGINEER OF RECORD. PERMANENT BRACING INCLUDES TOP CHORD BRACING, BOTTOM CHORD BRACING, COMPRESSION WEB MEMBER BRACING AND GABLE END LATERAL BRACING. 2. RECIEPT, STORAGE, ERECTION, FIELD INSTALLATION AND FIELD ASSEMBLY IS THE RESPONSIBILITY OF THE CONTRACTOR. IN THE ABSENCE OF SPECIFIC BRACING REQUIREMENTS, THE CONTRACTOR SHALL ENSURE THAT THE TRUSSES ARE BRACED IN ACCORDANCE WITH BCSI-03. 3. NEVER EXCEED THE DESIGN LOADING SHOWN AND NEVER STACK MATERIALS ON INADEQUATELY BRACED TRUSSES. 4. PROVIDE COPIES OF THE TRUSS DESIGN TO THE BUILDING DESIGNER, ERECTION SUPERVISOR, PROPERTY OWNER AND ALL OTHER INTERESTED PARTIES. 5. TOP CHORDS MUST BE SHEATHED OR PURLINS PROVIDED AT SPACING SHOWN ON DESIGN. BUILDING DESIGNER OR ENGINEER OF RECORD REQUIRED TO PROVIDE THIS-SEE NOTE 1 ABOVE. 6. BOTTOM CHORDS REQUIRE RIGID CEILING OR CONTINUOUS LATERAL BRACING AT SPACING NOTED ON TRUSS PROFILE. BUILDING DESIGNER OR ENGINEER OF RECORD REQUIRED TO PROVIDE THIS-SEE NOTE 1 ABOVE. 7. TRUSS TO TOP PLATE AND ALL OTHER CONNECTIONS NOT SHOWN ARE THE RESPONSIBILITY OF THE BUILDING DESIGNER. 8. DO NOT CUT OR ALTER TRUSS MEMBERS OR PLATE WITHOUT PRIOR APPROVAL OF A PROFESSIONAL ENGINEER. FOR TRUSS REPAIR DRAWINGS, EMAIL REPAIR REQUEST TO CUSTOMERSERVICE@TRUEHOUSE.COM. EMAIL SHOULD CONTAIN LOT NUMBER, SUBDIVISION, TRUSS NUMBER, SPECIFIC SCOPE OF REPAIR, AND CONTRACTOR CONTACT INFO. 4,5 3.8 1.14 SYMBOL INDICATES REQUIRED LATERAL BRACING. PERMANENT SYMBOL AND TEXT INDICATES 4 x 5 LATERAL BRACING IS THE INDICATES LOCATION WHERE REQUIRED SIZE AND LOACTION OF RESPONSIBILITY OF THE BUILDING BEARINGS(SUPPORTS)OCCUR. TRUSS PLATE. PLATE TEETH MUST •✓•I =� DESIGNER. ALL BEARINGS ARE CONSIDERED BE FULLY EMBEDDED INTO TO BE NO 2 SYP(UNO). LUMBER AND PLATES MAY NOT BE CUT OR ALTERED. 3 x 8 4;8 2 x 4 4 x 5 ` GENERAL NOTES AND DETAILS 8-11-15 fro DIMINSIONS ARE SHOWN IN FEET-INCHES-SIXTEENTHS. APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 T ueHouse JACKSONVILLE,FL 32224-904.821.5200 11-1\1 X THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. GABLE TRUSS WEB GABLE TRUSS WEB 2x6 NO 2 SYP "L" BRACE 2x6 NO 2 SYP "T" BRACE FASTENED TO GABLE WEB a� FASTENED TO GABLE WEB � M``� W/.131" x 22" AT 6" O.C. r W/.131" x 22" AT 6" O.C. I� SECTION A-A SECTION A-A OPTION 1 OPTION 1 (9' 8" - 12' 0") (9' 8" - 12' 0") 2x4 NO 2 SYP "L" BRACE GABLE TRUSS WEB 2x4 NO 2 SYP "T" BRACE GABLE TRUSS WEB FASTENED TO GABLE WEB FASTENED TO GABLE WEB W/.131" x 22" AT 6" O.C. W/.131" x 22" AT 6" O.C. `i'� A 1 11 SECTION B-B SECTION B-B OPTION 2 OPTION 2 a_ (3' 8" - 9' 7") (3' 8" - 9' 7") II iY) II 1 * VERTICAL WEBS 3' 8" OR — LESS DO NOT REQUIRE CONNECTION BETWEEN BOTTOM CHORD OF GABLE BRACES GABLE END TRUSS AND WALL, AS WELL AS THE i _ ; I DESIGN AND SPECIFICATION OF PERMANENT :, A ; A = 1 BRACING OF THE ROOF SYSTEM IS THE ;. B 11 B • * RESPONSIBILITY OF THE BUILDING DESIGNER. 1 kil v hiliiiiiiiiiiiiiiii4Hip GABLE END BRACING DETAIL 1 i i i (90 CONTINUOUS BEARING UNLESS NOTED OTHERWISE fiA rra APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 .ueHo use JACKSONVILLE,FL 32224-904.821.5200 ,r1 1 X THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. (3).131" x 3" TOE-NAILS @ TOP & BOTTOM CHORD CONNECTION. (NAILS THROUGH BACK SIDE OF GIRDER INTO END GRAIN OF JACK TRUSS ARE NOT ALLOWED) JACK JACK (3).131" x 3" TOE-NAILS @ TOP & BOTTOM CHORD CONNECTION FOR CORNER JACK. SOME CORNER JACKS MAY REQUIRE z SIMPSON LS30 IN LIEU OF TOE-NAILS. a JACK REFER TO SHOP DRAWINGS. F- z 7\ w U w JACK QLi' J d rz d LL o O O -- - (2).131" x 3" TOE-NAILS @ TOP & BOTTOM CC \\\� JACK CHORD CONNECTION. fY O U U U Q Q Q "HJ" GIRDER VARIES/ / TYPICAL HIP SET NAILING DETAIL r TI..I ,0*/\A no APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 T�.ueHo use JACKSONVILLE,FL 32224-904.821.5200 pitrw L.X THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. 24" TYP I I I k X X X N X X COMMON TRUSSES - @ 24" O.C. o I I z mwDESw J MAX 12"OVERHANG UNLESS /LEET IGNED BY OTHERSQp t 0 0 .�/ 24" O.C. O U a . GP �o wc, \\ I 4 , COMMON TRUSSES • @ 24" O.C. 0 .._ I COMMON I KUSSES (.. •. . PARTIAL TRUSS LAYOUT 2x4 NO 2 SYP NAILER ROOF SHEATHING OR PURLINS. FASTEN VALLEY ASTENED TO EACH COMMON IF DECKING IS NOT INSTALLED BELOW TRUSS TO NAILER TRUSS W/(2).131"x 21" VALLEY TRUSSES, PULINS MUST BE W/.131"x 22" INSTALLED FOR TOP CHORD BRACING. 6" O.C. SEE INDIVIDUAL TRUSS PROFILE FOR PURLIN AND SPACING. '� � NORD FIELD BEVEL VALLEY SOP G TRUSS BOTTOM CHORD •‘A-C\2' N-C\ FASTEN VALLEY TRUSS TO TCFiTCH COMMON TRUSS •�► TO EACH COMMON TRUSS W/(2).131"x 2i" ROOF SHEATHING 1' Cp VALLEY TRUSS FRAMING DETAIL ,A SOP GNO S ••0-•'. , 0 TH ....... APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 T�ueHouse JACKSONVILLE,FL 32224-904.821.5200 . 1"' GX THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. i IGGYBACK TRUSS 6"x 8"x z'PLYWOOD(or 1s'OSB)GUSSET APPLIED TO EACH FACE SPACED 48"O.C. i FASTEN WITH(4)8d COMMON INTO EACH CHORD FROM EACH SIDE(TOTAL 16 NAILS). MAXIMUM PURLIN SPACING 36"O.C. REFER TO INDIVIDUAL BASE TRUSS DESIGN FOR ACTUAL TOP CHORD PURLIN SPACING. In • • 1 0l Ki:4 (fl' 0: 9'4' ilii`' PIGGYBACK TRUSS 0 Q V-44 \ 1••••• ,.1.' ,... .,, .,, ,,,,b , \ I ATTACH PURLIN TO TOP CHORD OF BASE TRUSS i EACH BASE TRUSS WITH(2).131"x 23' h 6',OA/ OPTION 1 MAXIMUM PURLIN SPACING 24"O.C. TO Gs, REFER TO INDIVIDUAL BASE TRUSS DESIGN (7)A. NO FOR ACTUAL TOP CHORD PURLIN SPACING. , �C /3Sy'OSC • 0 i 0 .,.. * 17- ^Z/ OS 041 4 +4, .c. DI 0 \-\ BASE TRUSS ATTACH PIGGY BACK TO EACH PURLIN FOR PIGGY BACK TRUSSES WITH SPANS LESS THAN 12'SCAB WITH(2).131"x 2i' MAY BE OMMITED PROVIDED THAT THE ROOF SHEATHING IS PIGGYBACK TRUSS CONNECTION DETAIL ATTACH PURLIN TO TOP CHORD OF * CONTINUOUS OVER JOINT(SHEATHING TO OVERLAP A MINIMUM EACH BASE TRUSS WITH(2).131"x 2i" OF 12"OVER JOINT). 1:1 f V\no OPTION 2 TH APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 1 .0 eHouse JACKSONVILLE,FL 32224-904.821.5200 Im‘l' IG.X THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. 36" MAXIMUM FLAT TOP CHORD SPAN FASTEN SCABS TO CONTINUOUS 2x4 NO 2 SYP RIDGE BEAM W/(2).131"x 22" R 2x4 NO 2 SYP BLOCKING BOE WEEN CAPS MN/ /J�NO2Sy FASTENED W/(2).131"x 22"AT EACH END /(,/sp.v„ • 3, C' •� �i /40 6, (1) PURLIN AT MIDSPAN OF BASE TRUSS ACH TRUSS TOP CHORD WITH (2).131"x 24" /\ CONVENTIONAL FRAMED PIGGYBACK DETAIL r (cL fit/\A na APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 T�.ueHo use JACKSONVILLE,FL 32224-904.821.5200 ritrw IX THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. REQUIRED FASTENERS ROOF TRUSS HANGER SUPPORTING GIRDER GIRDER BOTTOM CHORD REACTION UPLIFT GIRDER TRUSS ONE PLY TRUSSES LUS26 1 PLY 2x6 746 746 (4) 0.148" x 1-1/2" (4) 0.148"x 3" HTU26 1 PLY 2x6 1823 691 (20) 0.148" x 1-1/2" (14)0.148" x 1-1/2" HTU26 2 PLY 2x6 2604 987 (20) 0.148" x 3" (14) 0.148" x 1-1/2" HTU28 2 PLY 2x8 3167 945 (26)0.148"x 3" (14) 0.148" x 1-1/2" TWO PLY TRUSSES HTU26-2 2 PLY 2x6 2940 1273 (20) 0.148" x 3" (14) 0.148" x 3" HGUS26-2 2 PLY 2x6 4393 1810 (20)0.148"x 3" (8) 0.148"x 3" HGUS28-2 2 PLY 2x8 6266 2717 (36)0.148" x 3" (12)0.148" x 3" THREE PLY TRUSSES HGUS26-3 2 PLY 2x6 _ 4393 _ 1810 (20) 0.148"x 3" (8) 0.148" x 3" HGUS28-3 2 PLY 2x6 6266 2717 (36) 0.148"x 3" (12) 0.148"x 3" !frf- IIIII grim e mE. 1 Z.4 o �, I FM di I 41 a 41/r 1 Y V LUS 1-PLY CONNECTION HTU 2-PLY CONNECTION 1/2" MAX GAP HTU 1-PLY CONNECTION 1/2" MAX GAP ROOF TRUSS CONNECTOR SPECIFICATIONS (-0 'CA rirci APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 Z'i.ueHo use JACKSONVILLE,FL 32224-904 821 5200 1-‘1— LI X THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. iN NI N ■�• 1 °- -r—� 1 I e _, a 1111\-NOTE 2 I NOTE 2 OTE 2 I OTE 1 � III NOTE 1 � � NM � ' ---1II I I�I I 'II I 31 2-PLY 3-1/2" WIDE BEAM 3-PLY 5-1/4" WIDE BEAM 4-PLY 7" WIDE BEAM 2-PLY 7" WIDE BEAM ASSEMBLY ASSEMBLY ASSEMBLY ASSEMBLY FASTENER TYPE 0.131"x 3"NAIL FASTENER TYPE 0.131"x 3"NAIL FASTENER TYPE 0.25"x 6"SDS FASTENER TYPE 0.25"x 6"SDS SCREW SCREW NUMBER OF ROWS 3 ROWS NUMBER OF ROWS 2 ROWS NUMBER OF ROWS 2 ROWS NUMBER OF ROWS 2 ROWS REQUIRED FASTENER SIDES ONE SIDE REQUIRED FASTENER SIDES TWO SIDES REQUIRED FASTENER SIDES TWO SIDES REQUIRED FASTENER SIDES TWO SIDES FASTENER ON CENTER FASTENER ON CENTER FASTENER ON CENTER FASTENER ON CENTER SPACING PER SIDE 6"O.C. SPACING PER SIDE 6"O.C. SPACING PER SIDE 12 O.C. SPACING PER SIDE 12"O.C. MINIMUM BEAM DEPTH 11-7/8" MINIMUM BEAM DEPTH 11-7/8" MINIMUM BEAM DEPTH 11-7/8" MINIMUM BEAM DEPTH 11-7/8" BEAM NOTES 1. IF 3 ROWS OF FASTENERS ARE REQUIRED,PLACE MIDDLE ROW SPACING OF FASTENERS AT THE CENTER OF THE BEAM DEPTH. 2. IF FASTENERS ARE REQUIRED ON BOTH SIDES,STAGGER ROWS SUCH THAT FASTENERS FALL HALF WAY BETWEEN FASTENER I I I I I 1 1 1 I I SPACING ON THE FIRST SIDE.REFER TO FIGURE 1. 3. STRUCTURAL ENGINEERING BEAM PLY FASTENER SCHEDULE TAKES PRECEDENCE OVER THIS SPECIFICATION. 4. BEAMS WITH LARGE POINT LOADS REQUIRE ADDITIONAL FASTENERS.SEE STRUCTURAL ENGINEERING FOR MORE INFORMATION. z OF SPACING FIGURE 1 TOP VIEW OF BEAM REQUIRED SPACING IF FASTENERS ARE REQUIRED ON EACH FACE OF BEAM BEAM PLY TO PLY FASTENER SPECIFICATIONS (i.4 fi*I\A no APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 T�.ueHouse JACKSONVILLE,FL 32224-904.821.5200 1-%T" X THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX . TECHNOLOGY. (2)10d TOP NAILS ER STRAP ---1/-- (2)10d TOP NAILS PER STRAP \ / N \ \ \ 1 / (1)10d FACE NAIL (1)10d FACE NAIL /—PER STRAP —PER STRAP V ,/'/ N \ / NN \ A (3)10d STRAIGHT \ (3)10d STRAIGHT \ AILS PER SIDE AILS PER SIDE 11 /iiik/z H 1 . / / \ THA422 / THA422 — —DEPTH AND PLIES VARY FLOOR TRUSS TO BEAM FLOOR TRUSS TO ROOF GIRDER ForA (2)10d TOP NAILS / lie PER STRA' (1)10d FACE NAIL ER STRAP \ (3)10d STRAIGHT ill AILS PER SIDE ip THA422 , MI THA422 CONNECTOR DETAIL WI4Igr FLOOR TRUSS TO FLOOR TRUSS TH AV\A la c. APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 1 .ueHouse JACKSONVILLE,FL 32224-904.821.5200 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2x6 "STRONGBACKS" SHOULD BE LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. STRONGBACK MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD. SECURELY FASTEN TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW. -=_-_\ X / a I!I / v/—=- . ATTACH TO VERTICAL ATTACH TO VERTICAL ATTACH 2x4 VERTICAL TO FACE WEB WITH (3)12. WEB WITH (3)12. •F TRUSS. FASTEN TO TOP COMMON WIRE NAILS. COMMON WIRE NAILS. AND BOTTOM CHORD WITH (2)12d COMMON IN EACH CHORD. =_NNiss 4N,7.; III i X / \ /_ N Mi ig. _� R R _ ,\\\\�\\\\ 3LOCKING 7 \ TRUSSES TYPICAL SPLICE 48" 2x6 AS REQUIRED `—BEARING WALL THE STRONGBACKS SHOULD EITHER BE SECURED TO ADJACENT PARTITION WALLS OR ALTERNATE"X" BRIDGING SHOULD BE USED TO TERMINATE THE BRACING MEMBERS. IF SPLICING IS NECESSARY, USE FLOOR TRUSS STRONG BACKS A 4'-0"LONG SCAB CENTERED OVER THE SPLICE AND JOIN WITH (12)12d NAILS EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4'-0"AND FASTEN WITH (12)12d COMMON WIRE NAILS STAGGERED AND EQUALLY SPACED. (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A (ii) VERTICAL) APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 T�.ueHouse JACKSONVILLE,FL 32224-904.821.5200 alm‘r- X THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. 71613 Ply:1 SEQN:20110/T50/SY42 ' Jo&Brian Adcock Residence Qty: 3 FROM:KS DRW: F01 Wgt:114.8Ibs / ... 09/25/17 10'3" 111'4"8 I 20'6" 10'3" 1'1 8 9'1"8 I3„1 2'6" 1 ri (TYP) III 1.5X3 1111.5X3=4X5[2] =4X4 1111.5X3 W=3X4 =4X4 =4X5[20] A B C D E F G H I J K L T _ \-1-' ..a\\\\ // \ /.\./ _NA 338 \../-\ / \ / I "Al X W V U T S R Q P 0 N =4X4 4X5[3] 1113X4[5][5] W=H0310 1111.5X3 =4X4 =4X5[19] =4X5 r 20'6" -i Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TOLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.271 F 896 360 X 1255 /- /- /- /- /- BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.495 F 490 323 N 1272 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.047 B - - X Min Brg Width Req= - Des Ld: 62.00 EXP:NA HORZ(TL): 0.085 B - - N Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearing N Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.356 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.571 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.591 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 0 0 G-H 0 -3817 I:NA GCpi:NA Plate Type(s): B-C 0-1835 H-I 0 -3817 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01.0630.10 C-D 0-3092 I-J 0 -3041 Lumber Hangers/Ties D-E 0-3844 J-K 0 -1758 F Value Set:13B(Effective 6/1/2013) Recommended hanger connections are based on F-G F-G 0-4090 K-L 1 0 manufacturer testedcapacities and calculations. 0-4090 Top chord 4x2 SP SS Bot chord 4x2 SP SS Conditions may exist that require different Webs 4x2 SP#3connections than indicated.Refer to manufacturer Maximum Bot Chord Forces Per Ply(lbs) publication for additional information. Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Bearing at location x=0' uses the following X-W 1065 0 S-R 4090 0 support conditions: Plating Notes Bearing X (0',10'1"2)HHUS46 V-U 3585 0 Q-P 3543 0 Supporting Member:(3)2x6 SP SS Dense All plates are 3X3 except as noted. (14)0.148"x3"nails into supporting U-T 4073 0 P-O 2519 0 Plate Shift Table member, T-S 4073 0 0-N 976 0 (6)0.148"x3"nails into supported JT Plate Lateral Chord JT Plate Lateral Chord member. Maximum Web Forces Per Ply(lbs) No Size Shift Bite No Size Shift Bite Webs Tens.Comp. Webs Tens. Comp. [2] 4X5 2.25 L 1.25 [3] 4X5 2.75 L 1.25 End Vertical Attachment [5] 3X4 1.75 L 1.25 [19] 4X5 2.75 R 1.25 Attach notched end vertical(s)to next end vertical A-X 0 -48 R-G 200 -117 [20] 4X5 2.25 R 1.25 using(3)qty.10d box or(0.128"x3"min)gun nails,or X-B 0-1600 G-Q 0 -604 Purlins (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire B-W 1222 0 0-I 529 0 staples,through wide face;or(3)qty.16-Gauge,1" W-C 0-1186 I-P 0 -796 In lieu of structural panels or rigid ceiling use purlins Crown(minimum),1-1/2"length wire staples on each C-V 810 0 P-J 829 0 to laterally brace chords as follows: narrow face. V-D 0 -783 J-O 0 -1208 Chord Spacing(in oc) Start(ft) End(ft) D-U 411 0 O-K 1242 0 TC 24 0.00 20.25 Additional Notes U-E • 0 -398 K-N 0 -1551 BC 120 0.00 20.25 +2x6 continuous strongback.See detail E-S 369 -275 L-N 0 -48 Apply purlins to any chords above or below fillers STRBRIBR1014 for bracing and bridging at 24"OC unless shown otherwise above. recommendations. S-F 82 -169 N-M 0 -8 Deflection Truss must be installed as shown with top chord up. Max JT VERT DEFL:LL:0.27"DL:0.26".See detail The overall height of this truss excluding overhang is DEFLCAMB1014 for camber recommendations. 1-8-0. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 g*/\ APEX Tru eHo use PE NoMichael Noel 08391owski Jeffrey No.58544son o58544son FE No 71457y PE No.Russell 71613 Ply:1 SEQN:20113/T69/SY42 Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: F02 Wgt:117.6lbs ... / ... 09/25/17 f' 10'4"8 1114 8I 206 H10'4"8 1' 9'1"8 g P i F-2 6"--I �3,H 11 2'6" 1111.5X3 1111.5X3=4X5[3] =4X4 1111.5X3 W=3X4 1=-4X4 4X5[21] T 271Y A B CDEF G+`\H\ I J K L M W /a\ - 1 (01012 IX W V U T S R 0 P 0 N =4X5 =4X4[4] 1113X4[6][6] W=H0310 1111.5X3 1113X4[18][18] =4X5[20] =4X5 1 20'6" 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.297 F 809 360 X 1254 /- /- /- /- /2.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.543 F 443 320 N 1259 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.054 B - - X Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL): 0.098 B - - N Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings X&N Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FSC 2014 RES Max TC CSI: 0.614 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.886 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.583 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 0 -1 G-H 0 -3753 I:NA GCpi:NA Plate Type(s): , B-C 0-1763 H-I 0 -3753 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01.0630.10 C-D 0-3016 I-J 0 -3000 Lumber End Vertical Attachment D-E 0-3763 J-K 0 -1738 Value Set:138(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical F- 0-4009K-L 1 0 G F-G 0-401111 Top chord 4x2 SP#2 using(3)qty.10d box or(0.128"x3"min)gun nails,or Bot chord 4x2 SP#1 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs) Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values narrow face. approved 1/30/2013 by ALSC X-W 995 0 S-R 4011 0 Additional Notes W-V 2508 0 R-Q 4009 0 Plating Notes +2x6 continuous strongback.See detail V-U 3507 0 Q-P 3492 0 All plates are 3X3 except as noted. STRBRIBR1014 for bracing and bridging U-T 3992 0 P-0 2488 0 recommendations. T-S 3992 0 0-N 966 0 Plate Shift Table JT Plate Lateral Chord JT Plate Lateral Chord Truss must be installed as shown with top chord up. No Size Shift Bite No Size Shift Bite The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) [3] 4X5 2.25 L 1.25 [4] 4X4 2.50 L 1.25 1-8-0. Webs Tens.Comp. Webs Tens. Comp. [6] 3X4 1.75 L 1.25 [18] 3X4 1.75 R 1.25 Y-X 0 -8 R-G 201 -128 [20] 4X5 2.75 R 1.25 [21] 4X5 2.25 R 1.25 X-A 0 -47 G-0 0 -577 X-B 0-1549 Q-I 506 0 Purlins B-W 1219 0 I-P 0 -780 In lieu of structural panels or rigid ceiling use purlins W-C 0-1183 P-J 814 0 to laterally brace chords as follows: C-V 807 0 J-0 0 -1191 Chord Spacing(in oc) Start(ft) End(ft) V-D 0 -779 0-K 1225 0 TC 24 0.25 20.25 D-U 407 0 K-N 0 -1535 BC 120 0.21 20.25 Apply purlins to any chords above or below fillers U-E 0 -394 L-N 0 47 at 24"(DC unless shown otherwise above. E-S 357 -264 N-M 0 8 S-F 70 -151 Deflection Max JT VERT DEFL:LL:0.30"DL:0.28".See detail DEFLCAMB1014 for camber recommendations. NOTES: NI- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (IrrH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fit/\ APEX TrueHouse PE NMichael60839 G Kozlowski 0391owski Jeffrey 58544son EPE No MurrayDerek B1457PE No Russet 7693 71613 Ply:1 SEQN:17308/T45/SY42 Jo&Brian Adcock Residence Qty: 2 FROM: DRW: F03 Wgt:128.8 lbs ... / ... 09/25/17 12'5" 137"8 22'9" I' 12'5, - - - + +1 2.,8 9'1"8 '� H-210„8_--2,6„-H 'F.12-12.1 (TYP) W=3X4 4X5[2] 1114X5[4][4] =4X5[6] =4X4 1111.5X3 =4X4 =4X5 A B C D E F G H 1 J K L M T TI AA- w3 \./ ` / \./\ /� /`,/`_/ \`/ �e + tore Z Y X W VU T S R Q P 0 N T =4X5 =5X5[5] =4X4[7] 1113X4[9][9] 1111.5X3 =4X4 =5X5 W=H0310 I---2' j 20'9" 1 I 22'9" I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.218 G 999 360 Y 2874 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.503 F 485 325 N 1221 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.032 0 - - Y Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL): 0.076 0 - - N Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings Y&N Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.729 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.623 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.696 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 1621 0 G-H 0 -3770 I:NA GCpi:NA Plate Type(s): B-C 1199 -329 H-I 0 -3770 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01A.0723.13 C-D 470-1939 I-J 0 -3276 Lumber End Vertical Attachment D-E 0-3042 J-K 0 -2345 Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical F- 0-3775 K-L 0 872 G F-G Top chord 4x2 SP SS using(3)qty.10d box or(0.128"x3"min)gun nails,or 0-3775 Bot chord 4x2 SP SS (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Webs 4x2 SP#3:W3 4x2 SP#2: staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs) Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values narrow face. approved 1/30/2013 by ALSC Z-Y 1 -1 T-S 3777 0 Additional Notes Y-X 0 -1560 S-R 3775 0 Special Loads +2x6 continuous strongback.See detail X-W 1245 -821 R-Q 3615 0 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) STRBRIBR1014 for bracing and bridging W-V 2605 -143 Q-P 2927 0 TC-From 114 plf at 0.12 to 114 plf at 22.62 recommendations. V-U 3462 0 P-0 1737 0 BC-From 10 plf at 0.00 to 10 plf at 22.75 Truss must be installed as shown with top chord up. U-T 3462 0 0-N 0 -1 TC-1230 lb Conc.Load at 0.25 The overall height of this truss excluding overhang is Plating Notes 1-8-0. Maximum Web Forces Per Ply(lbs) All plates are 3X3 except as noted. Webs Tens.Comp. Webs Tens. Comp. Z-A 6 -11 F-S 213 -169 Plate Shift Table AA-Z 3 -5 G-R 89 -230 JT Plate Lateral Chord JT Plate Lateral Chord A-Y 0-2033 R-I 499 -294 No Size Shift Bite No Size Shift Bite Y-B 0-1575 I-Q 0 -537 [2] 4X5 0 1.50 [4] 4X5 1.25 L 1.25 B-X 1462 0 Q-J 555 0 [5] 5X5 2.75 L 1.25 [6] 4X5 2.25 L 1.25 X-C 0-1515 J-P 0 -924 [7] 4X4 2.50 L 1.25 [9] 3X4 1.75 L 1.25 C-W 1206 0 P-K 965 0 Purlins W-D 0-1160 K-0 0 -1374 In lieu of structural panels or rigid ceiling use purlins V- 781 2 -L 1385 0 E L V-E to laterally brace chords as follows: 0 -752 L-N 0 -1143 Chord Spacing(in oc) Start(ft) End(ft) E-T 554 0 N-M 0 64 TC 24 0.12 22.50 T-F 74 -638 BC 120 0.00 22.50 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. (1111rH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fit/\ APEX TrueHouse PE Noel 008Kozlowski Jeffrey No No.58544 FEPE No 71457y PE No.77769311 71613 Ply:1 SEAN:17337/T28/SY42 Jo&Brian Adcock Residence Qty: 1 FROM: DRW: F03A Wgt:169.4 lbs ... / ... 09/25/17 I 12'5" 1137"8 I 22'9" I 12'5" 1'2"8 9'1"8 H 1'11"~I-2'6"--I 12212.1 (TYP) 1II4X4(R) =6X6 Itl5X7(R) IP5X7(R) W=3X4 W=3X4 =5X5 1114X825 A B C D E FG IIIHXI J K L )[25] T T ' T3 N 1 4 1 _:\ \\ t\./ \_/ \"/ j\ / \_/ \ / �e o. AA Z Y X W V U T S R 0 P Oi T =3X4 =4X8 5X5[5] =4X5[7] =4X4 =3X3[12] =3X3 •3X3 =4X4 =5X5[24] 1113X3 W=3X8 111 1.5X3 I-2' 1 zo'9 ._ . i I" 22'9" I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.198 H 999 360 z 3330 1- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.462 G 527 325 0 1202 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.034 0 - - Z Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL):0.087 0 - - 0 Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings Z&0 Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.479 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.980 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.750 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 2369 0 G-H 0 -3814 I:NA GCpi:NA Plate Type(s): B-C 1872 -107 H-I 0 -3808 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 `C-D 1026 -1812 I-J 0 -3808 Lumber End Vertical Attachment D-E 354 -2992 J-K 0 -3336 Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical F- 0-3644 K-L 0 -2894 G Top chord 4x2 SP SS:T3,T4 4x2 SP#2: using(3)qty.10d box or(0.128"x3"min)gun nails,or F-G 0-3644 L-M 0 894 Bot chord 4x2 SP#2:B2 4x2 SP#1: (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs) Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values narrow face. approved 1/30/2013 by ALSC AA-Z 0 -7 U-T 3814 0 Additional Notes Z-Y 0-2307 T-S 3814 0 Special Loads Y-X 1074-1430 S-R 3669 0 +2x6 continuous strongback.See detail ----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) STRBRIBR1014 for bracing and bridging X-W 2522 -647 R-Q 2987 0 TC-From 114 plf at 0.12 to 114 plf at 22.62 recommendations. W-V 2522 -647 Q-P 1777 0 BC-From 10 plf at 0.00 to 10 plf at 22.75 V-U 3445 -84 P-O 5 -1 TC-1638 lb Conc.Load at 0.12 Truss must be installed as shown with top chord up. The overall height of this truss excluding overhang is Plating Notes 1-8-0. Maximum Web Forces Per Ply(lbs) All plates are 4X5(R)except as noted. Webs Tens.Comp. Webs Tens. Comp. AA-A 53 0 G-T 172 -102 Plate Shift Table AB-AA 0 -40 H-S 203 -260 JT Plate Lateral Chord JT Plate Lateral Chord A-Z 0-2923 S-J 478 -407 No Size Shift Bite No Size Shift Bite Z-B 0-1566 J-R 39 -515 [5] 5X5 3.00 L 1.25 [7] 4X5 2.75 L 1.25 B-Y 1575 0 R-K 542 0 [12] 3X3 1.75 L 1.25 [24] 5X5 2.75 R 1.25 Y-C 0-1608 K-Q 0 -918 [25) 4X8 1.25 R 2.75 C-X 1285 0 Q-L 957 0 Purlins X-D 0-1241 L-P 0 -1367 D-V 855 0 P-M 1381 0 In lieu of structural panels or rigid ceiling use purlins V-E 0 -824 M-O 0 -1147 to laterally brace chords as follows: E-U 659 0 O-N 0 -43 Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.12 22.50 U-G 26 -723 BC 97 0.00 22.50 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 611) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ Tru eflo use PE Noel GO K3oozlowski Jeffrey No.58544son o58544son Derek B PE No.71457y PE No.Adam KRu 779311 APEX 71613 Ply:1 SEAN:17398/T89/SY42 Jo&Brian Adcock Residence Qty: 5 FROM: DRW: F04 Wgt:98.0lbs ... / ... 09/25/17 710 8 103 I 8 I 182" I 7'10"8 2'5" 7'10"8 I-2'6" I 2'6"12--I 2'6'12--I I--2'6"12 -I 2'6"12-I (TYP) 1111.5X3 =4X8 1111.5X3 -. 3X3[5] =3X3[8] 1111.5X3 =4X8 1111.5X3 A B C D E F G H 4 I T1: h 'Is..1" 71/'"._ r.... _s_10.1"2 N M L K J I =4X5 =3X8[4] 1111.5X3 1111.5X3 =3X8[10] =4X5 A 182" i Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udell U# Loc R /U /Rw /Rh 1 RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.239 L 910 360 N 1126 /- /- /- /- /- BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.539 L 404 290 I 1126 /- /- /- /- /- BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.040 I - - N Min Brg Width Req= - Des Ld: 62.00 EXP:NA HORZ(TL): 0.093 B - - I Min Brg Width Req= - NCBCLL:W.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.837 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.942 Chords Tens.Comp. Chords Tens. Comp. Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.598 A-B 0 0 E-F 0 -2748 C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: B-C 0-2748 F-G 0 -2748 I:NA GCpi:NA Plate Type(s): C-D 0-2748 G-H 0 0 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 D-E 0-3280 Lumber Hangers/Ties Value Set:13B(Effective 6/1/2013) Recommended hanger connections are based on Maximum Bot Chord Forces Per Ply(lbs) Top chord 4x2 SP#1 manufacturer tested capacities and calculations. Chords Tens.Comp. Chords Tens. Comp. Bot chord 4x2 SP#1 Conditions may exist that require different N-M 1672 0 K-J 3280 0 Webs 4x2 SP#3 connections than indicated.Refer to manufacturer M-L 3280 0 J-I 1672 0 publication for additional information. Lumber value set"13B"uses design values Recommended hanger connections are based on L-K 3280 0 approved 1/30/2013 by ALSC g manufacturer tested capacities and calculations. Plate Shift Table Conditions may exist that require different Maximum Web Forces Per Ply(lbs) connections than indicated.Refer to manufacturer Webs Tens.Comp. Webs Tens. Comp. JT Plate Lateral Chord JT Plate Lateral Chord No Size Shift Bite No Size Shift Bite publication for additional information. A-N 0 -123 K-E 134 -100 [4] 3X8 4.00 L 1.25 [5] 3X3 1.25 R 1.25 Bearing at location x=0' uses the following N-B 0-1939 E-J 0 -850 [8] 3X3 1.25 L 1.25 [10] 3X8 4.00 R 1.25 support conditions: B-M 1255 0 F-J 0 329 Bearing N (0',10'1"2)HHUS46 Supporting Member:(3)2x6 SP SS Dense C-M 0 -329 J-G 1255 0 Purlins (14)0.148'x3"nails into supportng M-D 0 -850 G-I 0 -1939 In lieu of structural panels or rigid ceiling use purlins member, D-L 134 -100 H-I 0 -123 to laterally brace chords as follows: (6)0.148"x3"nails into supported Chord Spacing(in oc) Start(ft) End(ft) member. TC 24 0.00 18.17 Bearing I (17'11",10'1"2)HHUS46 BC 120 0.00 18.17 Supporting Member:(2)2x6 SP SS Dense Apply purlins to any chords above or below fillers (14)0.148"x3"nails into supporting at 24"OC unless shown otherwise above. member, Deflection (6)0.148"x3"nails into supported member. Max JT VERT DEFL:LL:0.24"DL:0.32".See detail DEFLCAMB1014 for camber recommendations. Additional Notes +2x6 continuous strongback.See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. The overall height of this truss excluding overhang is 1-8-0. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (9Trif) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer y� Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Derek B APEX Tru eHo use PE Noel GO K3oozlowski Jeffrey No 58544son PE No 71457y PE No.Russell 71613 Ply:1 SEAN:17313/T105/SY42 Jo&Brian Adcock Residence Qty: 2 FROM: DRW: F05 Wgt:161.0 lbs ... / ... 09/25/17 12'5" 131" 22'9"8 I12.5 I 1'3" I 9'1"8 'I I~2'0"8_I T6"-H I- 1-I (TYP) 114X5(R) W=3X4 m5X5 1114X8[4][4] 1115X7(R) 1114X5(R) W=3X4 1113X4(R) 1114X51114X5(R) 114X5(R) w5X5 1114X8[25][25] A B C D T1 E F G H I J K L MN T I. - &,, _i_. AB --- / \ / \ / \ 4 / \ / \,./ \,/- AA Z Y X W V U T S R Q P O =4X55X5[5] m4X5[7] =4X4 1111.5X3 =4X4[22] =5X5[24] W=H0310 I-2' j 20'9"8 j I 2278 I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc LIdefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.201 H 999 360 Z 2865 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.462 G 528 325 0 1224 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.034 0 - - Z Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL): 0.082 0 - - 0 Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings Z&0 Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.995 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.931 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI:0.697 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 1579 0 G-H 0 -3951 I:NA GCpi:NA Plate Type(s): B-C 1151 -356 H-I 0 -3945 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01A.0723.13 C-D 416-2025 I-J 0 -3945 Lumber End Vertical Attachment D-E 0-3180 J-K 0 -3426 Value Set:13B(Effective 6/1/2013) Attach notched end verticals)to next end vertical F-F 0-3 K- 0 -29 49 Top chord 4x2 SP#2 Ti: 4x2 SP SS: using(3)qty.10d box or(0.128"x3"min)gun nails,or F-G 0-3803 803 L-M M 0 -911 Bot chord 4x2 SP#2:B2 4x2 SP SS: (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs) Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values narrow face. approved 1/30/2013 by ALSC AA-Z 19 0 U-T 3952 0 Additional Notes Z-Y 0-1510 T-S 3951 0 Special Loads +2x6 continuous strongback.See detail Y-X 1298 -780 S-R 3778 0 -----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) STRBRIBR1014 for bracing and bridging X-W 2724 -77 R-Q 3059 0 TC-From 114 plf at 0.12 to 114 plf at 22.67 recommendations. W-V 2724 -77 Q-P 1813 0 BC-From 10 plf at 0.00 to 10 plf at 22.79 V-U 3620 0 P-O 5 -2 TC-1226 lb Conc.Load at 0.36 Truss must be installed as shown with top chord up. The overall height of this truss excluding overhang is Plating Notes 1-8-0. Maximum Web Forces Per Ply(lbs) All plates are 3X3 except as noted. Webs Tens.Comp. Webs Tens. Comp. Plate Shift Table AA-A 0 -124 G-T 155 -125 AB-AA 117 0 H-S 132 -276 JT Plate Lateral Chord JT Plate Lateral Chord A-Z 0-1974 S-J 522 -296 No Size Shift Bite No Size Shift Bite Z-B 0-1652 J-R 0 -546 [4] 4X8 1.25 L 2.75 [5] 5X5 2.75 L 1.25 B-Y 1463 0 R-K 568 0 [7] 4X5 2.75 L 1.25 [22] 4X4 2.25 R 1.25 Y-C 0-1501 K-Q 0 -945 [24] 5X5 2.75 R 1.25 [25] 4X8 1.25 R 2.75 C-X 1226 0 Q-L 986 0 Purlins X-D 0-1180 L-P 0 -1396 D-V 786 0 P-M 1408 0 In lieu of structural panels or rigid ceiling use purlins V-F 0 -758 M-O 0 -1165 to laterally brace chords as follows: F-U 573 0 O-N 0 45 Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.12 22.54 U-G 62 -628 BC 120 0.00 22.54 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. (111P-H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fiV\ TrueHouse PE NMichael GO 3oozlowski PE No 58544 y P on PE No.14Derek B 5y APE No.Russell APEX 71613 Ply:1 SEAN:17342/T86/SY42 ' Jo&Brian Adcock Residence Qty: 1 FROM: DRW: F05A Wgt:166.6 lbs ... / ... 09/25/17 12'5" 13'8" 2278 12,5" I 1,3" I- 9'1"8 H 2,0"8--I--2,6„ I 1-'I (TYP) 1113X4[14](14] W=3X4 1114X4(8) =6X6 1115X7(8) IIISX7(R) =5X5 1114X5(8) W=3X4 114X5(R) =5X5 1114X8[25](25] A B C D E FG IIIHXI5 J K L M T3 ,_N 1 1 AB\ _/ _/\_/\ /� �, /\ /\_/ \. _ 10, 2 AA ZM Y X W V U T S R Q P 04 4X8 m5X5[5] m4X5[7] =4X4 113X3[12][12] 4X4 =5X5[24) W=3X8 1111.5X3 I--2' -k 2078 -1 I 22'9"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,P1 in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.197 H 999 360 z 3455 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.463 G 527 325 0 1201 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.033 0 - - Z Min Brg Width Req= 1.6 Des Ld: 62.00 EXP:NA HORZ(TL): 0.086 0 - - 0 Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings Z&0 Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.513 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.976 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.757 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 2520 0 G-H 0 -3804 I:NA GCpi:NA Plate Type(s): B-C 2014 -57 H-I 0 -3799 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 1148-1773 I-J 0 -3799 Lumber End Vertical Attachment D-E 457-2964 J-K 0 -3331 L Value Set:13B(Effective 6/1/2013) Attach notched end verticals)to next end vertical F-G 0-3627 K-M 0 -2893 Top chord 4x2 SP SS:T3,T4 4x2 SP#2: using(3)qty.10d box or(0.128"x3"min)gun nails,or F-G 0-3627 L-M 0 893 Bot chord 4x2 SP#2:B2 4x2 SP#1: (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs) Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values narrow face. approved 1/30/2013 by ALSC AA-Z 0 -7 U-T 3805 0 Additional Notes Z-Y 0-2457 T-S 3804 0 Special Loads Y-X 1029-1563 S-R 3662 0 +2x6 continuous strongback.See detail (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) STRBRIBR1014 for bracing and bridging X-W 2488 -759 R-Q 2982 0 TC-From 114 plf at 0.12 to 114 plf at 22.67 recommendations. W-V 2488 -759 Q-P 1774 0 BC-From 10 plf at 0.00 to 10 plf at 22.79 Truss must beinstalledchord u V-U 3422 -178 P-0 5 -1 as shown with TC-1749 lb Conc.Load at 0.12top p. The overall height of this truss excluding overhang is Plating Notes 1-8-0. Maximum Web Forces Per Ply(lbs) All plates are 3X3 except as noted. Webs Tens.Comp. Webs Tens. Comp. AA-A 46 0 G-T 181 -100 Plate Shift Table AB-AA 0 -33 H-S 215 -261 JT Plate Lateral Chord JT Plate Lateral Chord A-Z 0-3108 S-J 477 -430 No Size Shift Bite No Size Shift Bite Z-B 0-1580 J-R 54 -513 [5] 5X5 3.00 L 1.25 [7] 4X5 3.00 L 1.25 B-Y 1590 0 R-K 540 0 [12] 3X3 1.75 L 1.25 [14] 3X4 1.25 R 2.75 Y-C 0-1624 K-Q 0 -916 [24] 5X5 2.75 R 1.25 [25] 4X8 1.25 R 2.75 C-X 1303 0 Q-L 955 0 Purlins X-D 0-1259 L-P 0 -1365 V In lieu of structural panels or rigid ceiling use purlins V-V-E 871 0 P-M 1379 0 E 0 -840 M-O 0 -1146 to laterally brace chords as follows: E-U 682 0 0-N 0 -43 Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.12 22.54 U-G 17 -751 • BC 93 0.00 22.54 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. 6111.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use E No 160 39lowski Jeffrey No.58544son o58544son FE No.71457y PE No 7 6311 71613 Ply:1 SEQN:17246/T76/SY42 Jo&Brian Adcock Residence Qty: 2 FROM:KS DRW: F06 Wgt:128.8 lbs ... / 09/25/17 9'11" 1 5" 22'5"8 F 9'11" 6'8� 12' _' H 1'6"-'I I---1,9"8 HI--2'6"--1----2'6"12-I---2'6"12-{ I--2'6"12-- 2'6'12-4--2,612-{ (TYP) -- 3X8 1113X3 =4X4 E4X5 -3X3 W=3X4 =4X4[17] =3X3 A B C D E F G H I J K L m i v‘,_ 1 Q 101''2 V "U T S R a ''P 0 N 4X5[1] =3X4 m4X5[7]W=3X4 m 3X4[12] =3X8 =3X3 =3X4 I-1'11"8 j 13'10" j 6'8" I 22'5"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pt in PSF) Def/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.118 N 693 360 U 1487 /- /- /- /- /3.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.331 N 247 240 P 1780 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.014 K - - U Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL):-0.031 N - - P Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings U&P Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.906 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.688 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.462 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 0 -45 G-H 770 -1216 I:NA GCpi:NA Plate Type(s): B-C 754 0 H-I 1742 0 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 540-1265 I-J 1742 0 Lumber End Vertical Attachment D-E 540-1265 J-K 449 0 Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical F- 760-1216 K-L 0 10 G Top chord 4x2 SP#2:T2 4x2 SP#1: using(3)qty.10d box or(0.128"x3"min)gun nails,or F-G 770-1216 Bot chord 4x2 SP#2 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs) Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values narrow face. approved 1/30/2013 by ALSC V-U 0 -690 R-Q 1228 -764 Additional Notes U-T 678 -597 Q-P 557 -1214 Special Loads +2x6 continuous strongback.See detail T-S 1232 -760 P-0 0 673 -----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) STRBRIBR1014 for bracing and bridging S-R 1232 -760 O-N 0 -240 TC-From 114 plf at 0.12 to 114 plf at 22.33 recommendations. BC-From 10 plf at 0.00 to 10 plf at 22.46 Truss must be installed as shown with topchord up. Maximum Web Forces Per Ply(lbs) 511 lb Conc.Load at 0.25 ( ) The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. Plating Notes 1-8-0. V-A 0 -383 Q-H 970 0 All plates are 1.5X3 except as noted. V-B 921 0 H-P 0 -1474 Plate Shift Table W-V 0 -174 I-P 0 -345 B-U 0 -894 P-J 0 -1255 JT Plate Lateral Chord JT Plate Lateral Chord U-C 0-1225 J-O 512 0 No Size Shift Bite No Size Shift Bite C-T 685 0 O-K 0 -478 [1] 4X5 2.75 L 1.25 [7] 4X5 2.00 L 1.25 D-T 0 -332 K-N 287 0 [12] 3X4 1.25 L 1.25 [17] 4X4 1.75 R 1.25 T-E 257 0 L-N 0 -100 Purlins E-R 0 -138 M-N 0 -25 F-Q 0 -349 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.12 22.33 BC 120 0.00 22.46 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Tr}{ 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fiV\ APEX Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell Ti u eHo u se PE No 60839 PE No 58544 PE No 71457 PE No.77693 71613 Ply:1 SEQN:17266/T70/SY42 ' Jo&Brian Adcock Residence Qty: 2 FROM:KS DRW: F07 Wgt:128.8 lbs ... / ... 09/25/17 9'11" I 11'5"_I 22'5.'8 9'11" 1'6 11'0.'8 H 1'9"8 HI-2,6"--1.--2'6.'12-4-2'6"12-{ I-2,612--{-2,6'12--{-2'6'12-H (TYP) _=3X3 3X4[3] =4X5 =3X3 W=3X4 =3X8 =3X4 A B C D E F G H I J K L T i- _ M m - 3'e 1 010'1"2 V "'U T S R Q I311P 0 N =4X5 w3X4[4] =4X5[7]W=3X4 =4X4 =3X8 =3X3 =3X4 H 1,11"8 -1- 14,9•,8 j 58"8 F. 22'5"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria A Maximum Reactions(lbs) TOLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.148 E 999 360 U 1603 /- /- /- /- /3.5 BOLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.338 E 512 240 p 1665 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.024 K - - U Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL): 0.057 A - - P Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings U&P Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.798 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.831 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.497 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 0 -43 G-H 388 -1561 I:NA GCpi:NA Plate Type(s): B-C 726 0 H-I 1273 0 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 260-1540 I-J 1273 0 Lumber End Vertical Attachment D-E 260-1540 J-K 308 0 Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical F- 388-15K-L 0 10 G F-G 388-156611 using(3)qty.10d box or(0.128"x3"min)gun nails,or Top chord 4x2 SP#1 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Bot chord 4x2 SP#2:B2 4x2 SP#1: G 16 f l tsapes,throughwide ace;or(3)qty.16-Gauge, ChordForces Per 4x2 SP#3g �1" Maximum Bot PI y(lbs) Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp. Lumber value set"130"uses design values narrow face. approved 1/30/2013 by ALSO V-U 0 -662 R-Q 1575 -382 Additional Notes U-T 812 -451 0-P 793 -793 Special Loads T-S 1579 -379 P-0 0 -382 +2x6 continuous strongback.See detail (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) STRBRIBR1014 for bracing and bridging S-R 1579 -379 0-N 0 -239 TC-From 114 plf at 0.12 to 114 plf at 22.33 recommendations. BC-From 10 plf at 0.00 to 10 plf at 22.46 Truss must be installed as shown with top chord up. Maximum Web Forces Per Ply(lbs) TC- 237 lb Conc.Load at 0.25 Webs Tens.Comp. Webs Tens. Comp. TC- 274 lb Conc.Load at 0.37 The overall height of this truss excluding overhang is 1-8-0. V-A 0 -368 Q-H 1044 0 Plating Notes V-B 883 0 H-P 0 -1488 All plates are 1.5X3 except as noted. W-V 0 -167 I-P 0 -342 Plate Shift Table B-U 0 -903 P-J 0 -1047 U-C 0-1369 J-0 433 0 JT Plate Lateral Chord JT Plate Lateral Chord C-T 850 0 0-K 0 -407 No Size Shift Bite No Size Shift Bite D-T 0 -383 K-N 285 0 [3] 3X4 1.25 R 1.25 [4] 3X4 1.25 L 1.25 T-E 306 -307 L-N 0 -100 [7] 4X5 2.25 L 1.25 E-R 23 -177 M-N 0 -24 Purlins F-0 0 -400 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.12 22.33 BC 120 0.00 22.46 Apply purlins to any chords above or below fillers at 24"00 unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer r■��+_ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 .L i ueHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:17363/T78/SY42 Jo&Brian Adcock Residence Qty: 1 FROM: DRW: F08 Wgt:100.8 lbs .. / _ 09/25/17 8'6"8 10'1"8 16'9" 1-* 8V8 I 17" I 67"8 if 1'11" ^--} 2'6" H 11'3"12 I 1'3„1I (TYP) =4X5 =4X4 1113X4[6][6] m3X4[8] 1111.5X3 1111.5X3 =4X4 A B C D E F G H I T 9li \ J 22 cor 1 T_ \./ \./ \ / \.� - 10'1"2 S R Q P 0 N M L K3 =4X4 3] =4X4[5] 1113X4[7][7] =3X4 =4X4 --1118 1 1498 A 1 16'9" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PS9 DefUCSI Criteria A Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udell U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.095 F 999 360 R 2345 /- /- /- /- /3.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.195 F 891 240 K 847 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL):-0.016 I - - R Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL):-0.036 I - - K Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings R&K Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.622 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.448 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI:0.499 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 1319 0 E-F 0 -1772 I:NA GCpi:NA Plate Type(s): B-C 982 -141 F-G 0 -1768 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 444-1167 G-H 0 -1436 Lumber End Vertical Attachment D-E 0-1763 H-I 0 571 Value Set:13B(Effective 6/1/2013) Attach notched end verticals)to next end vertical Top chord 4x2 SP SS using(3)qty.10d box or(0.128"x3"min)gun nails,or Maximum Bot Chord Forces Per Ply(lbs) Bot chord 4x2 SP SS (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Chords Tens.Comp. Chords Tens. Comp. Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" S-R 1 1 O-N 1772 0 Crown(minimum),1-1/2"length wire staples on each Lumber value set"13B"uses design values narrow face. R-Q 0-1267 N-M 1701 0 approved 1/30/2013 by ALSC Q-P 771 -693 M-L 1137 0 Additional Notes P-0 1546 -195 L-K 0 -1 Special Loads +2x6 continuous strongback.See detail -----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) STRBRIBR1014 for bracing and bridging Maximum Web Forces Per Ply(lbs) TC-From 114 plf at 0.12 to 114 plf at 16.62 recommendations. Webs Tens.Comp. Webs Tens. Comp. BC-From 10 plf at 0.00 to 10 plf at 16.75 Truss must be installed as shown with topchord TC-1062 lb Conc.Load at 0.25 up. S-A 6 -9 O-E 0 -386 The overall height of this truss excluding overhang is T-S 3 -4 F-N 115 -176 Plating Notes 1-8-0. A-R 0-1693 N-G 292 -310 All plates are 3X3 except as noted. R-B 0-1224 G-M 42 -421 Plate Shift Table B-O 1047 0 M-H 476 0 Q-C 0-1075 H-L 0 -898 JT Plate Lateral Chord JT Plate Lateral Chord C-P 734 0 L-I 908 0 No Size Shift Bite No Size Shift Bite P-D 0 -729 I-K 0 -789 [3] 4X4 1.25 R 1.25 [5] 4X4 2.25 L 1.25 D-0 708 0 K-J 0 -46 [6] 3X4 S 1.50 [7] 3X4 1.75 L 1.25 [8] 3X4 1.50 L 1.25 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.12 16.50 BC 120 0.00 16.50 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (119-14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ APEX Tru eHo u se Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:2 SEQN:17272/T24/HIPM . Jo&Brian Adcock Residence Oly: 1 FROM:KS DRW: FG01 Wgt:154.0 lbs ... / ... 09/25/17 3'10"11 92"5 1478 3'10"11 I 5'3"11 I 573 12 4 p =5BX7(**) 1113CX4 T2 1116X8(***)(I) DT A , N 3X8(A1)A r 43 J 1 10'1"2 G F SEH 1113X4 =8X12 1114X4(**) rr 14'6"8 4'0"7 _ 5'1"15 573 H 4'0"7 9'2"5 I 14'9"8 Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.165 C 999 360 A 1806 /_ /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.336 C 519 240 H 2997 /- /- /- /- /5.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.021 B - - A Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL): 0.043 B - - H Min Brg Width Req= 1.6 NCBCLL:10.00 Mean Height:NA ft Code 1 Misc Criteria Creep Factor:1.5 Bearings A&H Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.775 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.633 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.962 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 0-2536 C-D 0 -3386 I:NA GCpi:NA Plate Type(s): B-C 0-3386 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 Lumber Plating Notes Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) (I)-plates so marked were sized using 0% Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2:T2 2x4 SP M-30: Fabrication Tolerance, 0 degrees Rotational A-G 2384 0 F-E 61 0 Bot chord 2x6 SP SS Dense Tolerance,and/or zero Positioning Tolerance. G-F 2424 0 Webs 2x4 SP#3:W4 2x4 SP#2: (**)3 plate(s)require special positioning.Refer to Lumber value set"13B"uses design values scaled plate plot details for special positioning Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC requirements. Webs Tens.Comp. Webs Tens. Comp. Nailnote Purlins B-G 348 0 F-D 3409 0 Nail Schedule:0.131"x3",min.nails In lieu of structural panels or rigid ceiling use purlins B-F 989 0 D-E 0 -1266 Top Chord:1 Row @ 8.75"o.c. to laterally brace chords as follows: C-F 0 -251 Bot Chord:1 Row @ 7.50"o.c. Chord Spacing(in oc) Start(ft) End(ft) Webs :1 Row @ 4"o.c. TC 24 0.00 14.79 Use equal spacing between rows and stagger nails BC 120 0.25 14.79 in each row to avoid splitting. Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Special Loads ----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC-From 116 plf at 0.00 to 116 plf at 3.95 TC-From 116 plf at 3.95 to 116 plf at 7.06 TC-From 58 plf at 7.06 to 58 plf at 12.33 TC-From 208 plf at 12.33 to 208 plf at 14.79 BC-From 10 plf at 0.00 to 10 plf at 7.06 BC-From 5 plf at 7.06 to 5 plf at 14.79 TC- 615 lb Conc.Load at 14.50 BC-1159 lb Conc.Load at 7.06 BC- 428 lb Conc.Load at 9.06,11.06 BC- 430 lb Conc.Load at 13.06 Additional Notes The overall height of this truss excluding overhang is 1-7-12. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. if TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer /�- \ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Tru eHo use E No Michael 08391owski pE No.58544son o58544son Derek No 7145Mu7y Adam K PE No 7 69311 APEX 71613 Ply:3 SEQN:17277/T71/COMN Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FG02 Wgt:260.4 lbs ... / ... 09/25/17 3'7"115'10"1 7'9"14 9'9"10 11'6"11 13'11" 3'7"11 I- 2'2"6 I 1'11"13 I 1'11"13 _I 1'9"1 I 2'4"5 12 =8X8(") =6X12(1) 1113X4 III3X4 =6X10 =6X10(")(I) 4 p C D E FT2 G H T BX8(C1) W ❑ I� J�1/ VV N 3X8(C1) // �j o N M L K J IP 1 =6X8 1114X8 =3X8 =6X10 =8X12 1114X8 I--1'6"8 1 4'1"3 1'8"14 1'9"1 2'5"5 2'0"5 1'10"5 4'1"3 I 5'10"1 I 7'7"2 I 10'0"6 I 12'0"11 I 13'11" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSP) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.206 L 802 360 O 6152 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.423 L 390 240 P 8777 /- /- /- /- /5.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.037 I - - 0 Min Brg Width Req= 2.2 Des Ld: 62.00 EXP:NA HORZ(TL): 0.077 I - - P Min Brg Width Req= 3.2 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings 0&P Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.765 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.964 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.632 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 18 0 E-F 0 -7894 I:NA GCpi:NA Plate Type(s): B-C 0-5776 F-G 0 -7705 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 0-6155 G-H 0 -4062 Lumber Plating Notes D-E 0 -7992 Value Set:13B(Effective 6/1/2013) (I)-plates so marked were sized using 0% Top chord 2x4 SP M-31:T2 2x6 SP SS Dense: Fabrication Tolerance, 0 degrees Rotational Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x6 SP SS Dense Tolerance,and/or zero Positioning Tolerance. Chords Tens.Comp. Chords Tens. Comp. Webs 2x6 SP SS Dense:W2 2x4 SP#2: (")2 plate(s)require special positioning.Refer to B-N 5477 0 L-K 7894 0 :W4 2x4 SP#3: scaled plate plot details for special positioning N-M 8762 0 K-J 5019 0 :W7 2x4 SP#1: requirements. M-L 8762 0 J-I 82 0 :W9 2x4 SP SS: Lumber value set"13B"uses design values Purlins approved 1/30/2013 by ALSC In lieu of structural panels or rigid ceiling use purlins Maximum Web Forces Per Ply(lbs) to laterally brace chords as follows: Webs Tens.Comp. Webs Tens. Comp. Nailnote Chord Spacing(in oc) Start(ft) End(ft) C-N 1818 0 F-K 0 -932 Nail Schedule:0.131"x3",min.nails TC 24 1.50 13.92 N-D 0-3089 K-G 3316 0 Top Chord:1 Row @ 3.25"o.c. BC 120 0.15 13.92 D-M 1747 0 G-J 0 -2496 Bot Chord:2 Rows @ 4.00"o.c.(Each Row) Apply purlins to any chords above or below fillers Webs 1 Row @ 4"o.c. at 24"OC unless shown otherwise above. D-L 216 -910 J-H 4603 0 Repeat nailing as each layer is applied.Use equal L-E 480 -152 H-I 0 -2778 spacing between rows and stagger nails in each row Additional Notes to avoid splitting. The overall height of this truss excluding overhang is 4"o.c.spacing of nails perpendicular and parallel to 1-6-12. grain required in area over bearings greater than 4" Special Loads ----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC-From 116 plf at -1.54 to 116 plf at 3.70 TC-From 58 plf at 3.70 to 58 plf at 5.67 TC-From 345 plf at 5.67 to 345 plf at 12.67 TC-From 208 plf at 12.67 to 208 plf at 13.92 BC-From 10 plf at 0.00 to 10 plf at 5.79 BC-From 5 plf at 5.79 to 5 plf at 13.92 TC- 273 lb Conc.Load at 5.67 TC-2083 lb Conc.Load at 12.67 BC-5318 lb Conc.Load at 5.79 BC-1255 lb Conc.Load at 7.81,9.81,11.81 NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61}{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Tru eHo use Michael G Kozlowski Jeffrey P ArnesonDerek B Murray Adam K Russell APEX PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:3 SEAN:17419/T73/FLAT Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FG03 Wgt:441.0 lbs ... / ... 09/25/17 12'10"13 I 5'5"2 I 7'8''11 1 10'3" I 12'6'9 I 15'0„14 I 177'3 i 20'6" 21013 2'6"5 239 265 239 265 265 2'10"13 =6X10(**) =4X8 1113X4 =8X8(**) =3X8 m3X8 6X10(**) A B C D E F G H I T 1 cv , `\ r liko, I 10'1"2 R Q P 0 N M L K J O 1114X5 =6X10 4X8 3X8 =H1010(**) =6X10 1114X5 (I) r 2'5"5 � 2'6"5 � 2'6"5 � 2,11°13 � 2'6„5 � z'6"5 � 2'6°5 � 2'5'5 1 2'5"5 4'11"10 7'5"15 10'5"12 13'0"1 15'6"6 18'0"11 20'6" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.233 E 999 360 R 5318 /- /- /- /- /- BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.639 E 384 327 J 5864 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.035 A - - R Min Brg Width Req= - Des Ld: 62.00 EXP:NA HORZ(TL): 0.095 A - - J Min Brg Width Req= 2.1 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearing J Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.547 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.696 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.717 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 0-3027 E-F 0 -7161 I:NA GCpi:NA Plate Type(s): B-C 0-5391 F-G 0 -6860 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01A.0723.13 C-D 0-7087 G-H 0 -5438 Lumber Plating Notes D-E 0-7190 H-I 0 -3074 Value Set:13B(Effective 6/1/2013) All plates are 5X7 except as noted. Topchord 2x6 SP SS Dense0% Maximum Bot Chord Forces Per Ply(lbs) (I)-plates so marked were sized using Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x6 SP SS Dense Fabrication Tolerance, 0 degrees Rotational Webs 2x6 SP SS Dense:W2,W15 2x4 SP#1: Tolerance,and/or zero Positioning Tolerance. R-Q 60 0 N-M 7043 0 :W4,W13 2x4 SP#2: (**)4 plate(s)require special positioning.Refer to Q-P 3581 0 M-L 5805 0 :W6,W9,W11 2x4 SP#3: scaled plate plot details for special positioning P-0 5780 0 L-K 3636 0 Lumber value set"13B"uses design values requirements. O-N 7190 0 K-J 66 0 approved 1/30/2013 by ALSC Purlins Maximum Web Forces Per Plylbs Nailnote In lieu of structural panels or rigid ceiling use purlins (lbs) Webs Tens.Comp. Webs Tens. Comp. Nail Schedule:0.131"x3",min.nails to laterally brace chords as follows: Top Chord:1 Row @ 4.00"o.c. Chord Spacing(in oc) Start(ft) End(ft) A-R 0-1680 N-F 137 0 Bot Chord:1 Row @12.00"o.c. TC 24 0.00 20.50 A-Q 3299 0 F-M 0 -508 Webs :1 Row @ 4"o.c. BC 120 0.00 20.50 Q-B 0-1537 M-G 1217 0 Repeat nailing as each layer is applied.Use equal Apply purlins to any chords above or below fillers B-P 2088 0 G-L 0 -1018 spacing between rows and stagger nails in each row at 24"OC unless shown otherwise above. p-C 0-1081 L-H 2078 0 to avoid splitting. The TC of this truss shall be braced with attached C-O 1507 0 H-K 0 -1562 Special Loads spans at 24"oc in lieu of structural sheathing. O-D 0 -542 K-I 3345 0 ----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Additional Notes E-N 0 -148 I-J 0 -1833 TC-From 432 plf at 0.00 to 432 plf at 20.50 Truss must be installed as shown with top chord up. BC-From 10 plf at 0.00 to 10 plf at 20.50 TC- 477 lb Conc.Load at 20.04 The overall height of this truss excluding overhang is BC- 164 lb Conc.Load at 1.81,3.81,5.81,7.81 1-7-12. 9.81,11.81,13.81,15.81,17.81,19.81 Hangers/Ties (J)Hanger Support Required,by others NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. 614) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ APEX Tru eHo use P No 1 60839 Kozlowski FErNo. 8544son pE No.71457y APE No.7 69311 71613 Ply:2 SEQN:17404/T90/FLAT Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FG04 Wgt:268.8 lbs ... / ... 09/25/17 4I � 27 1'8"4 6'6"15 81011 11'0"10 13'4"6 15'5"13 17'10"1 20'3"8 22'9" 2,7" I I 2,3"11 I 2'3"11 I 2'1"15 I 2,3"11 I 2'1"7 I 2'4"4 I 2,5"7 I 2'5"8 8X12(") =4X4 =5X7(••) =3X8 =4X5 =H0510 1113X4(") Ate\ B C D E F G H / I J r,,, ,,::,,_ , K rcc, E 'l 111LI- .1 110'1"2 V U T S R 0 P O N M PIL T 1113X4(") 1116X10(") =8X12 =4X4 =8X8(") =4X5 =5X5 =5X5 -2' j 20'9" 1 2'1" { 2'6"3 I 2,3"11 I 73"11 I 77"3Z3'11 2,3"11 I 23 11 I 21 15 I 2'5"8 2'1" 6'3"7 8'7"3 10'10"14 13'6"2 15'9"13 18'1"9 20'3"8 22'9" 1'84 { 3'9"4 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in lac L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.324 F 766 360 U 8997 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.634 F 391 330 L 2041 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.071 A - - U Min Brg Width Req= 4.7 Des Ld: 62.00 EXP:NA - HORZ(TL): 0.139 A - - L Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings U&L Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.873 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.919 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI:0.972 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 131 -6 F-G 0 -5423 I:NA GCpi:NA Plate Type(s): B-C 0-5602 G-H 0 -5391 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01A.0723.13 C-D 0-6359 H-I 0 -4146 Lumber Purlins D-E 0-6178 I-J 0 -3025 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins E-F 0-5427 J-K 0 8 Top chord 2x4 SP M-30 to laterally brace chords as follows: Bot chord 2x6 SP SS Dense Chord Spacing(in oc) Start(ft) End(ft) Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3:W4 2x4 SP SS: TC 24 0.00 22.75 Chords Tens.Comp. Chords Tens. Comp. BC 120 0.00 22.75 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers V-U 3 0 Q-P 5423 0 approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. U-T 946 -10 P-O 4315 0 The IC of this truss shall be braced with attached T-S 5711 0 0-N 3195 0 Nailnote spans at 24"oc in lieu of structural sheathing. S-R 6363 0 N-M 1750 0 Nail Schedule:0.131"x3",min.nails R-Q 6123 0 M-L 1750 0 Top Chord:1 Row @ 9.75"o.c. Additional Notes Bot Chord:1 Row @ 3.75"o.c. Truss must be installed as shown with topchord up. Maximum Web Forces Per Plylbs Webs :1 Row @ 4"o.c. Webs ( ) Use equal spacing between rows and stagger nails The maximum concentrated load is 7618# Webs Tens.Comp. Tens. Comp. in each row to avoid splitting. The overall height of this truss excluding overhang is A-V 0 -117 Q-F 39 -42 4"o.c.spacing of nails perpendicular and parallel to 1-8-0. A-U 3 -157 G-P 0 -285 grain required in area over bearings greater than 4" U-B 0-4268 P-H 1278 0 Special Loads B-T 5978 0 H-O 0 -768 -----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) T-C 0 -493 O-I 1129 0 TC-From 264 plf at 0.00 to 264 plf at 4.00 C-S 770 0 I-N 0 769 TC-From 114 plf at 4.00 to 114 plf at 22.75 S-D 0 -193 N-J 1485 0 BC-From 10 plf at 0.00 to 10 plf at 22.75 D-R 285 -219 J-M 33 0 BC-7617 lb Conc.Load at 4.19 R-E 249 -128 J-L 0 -1969 E-Q 162 -826 K-L 0 -66 Plating Notes All plates are 3X4 except as noted. (")6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'1441) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fiV\ APEX Tru eHo use Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:2 SEON:17407/T87/FLAT Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FG05 Wgt:268.8 lbs / ... 09/25/17 4I 4 -1 27 1'8"4 6'6"10 8'10"1 10'11"11 13'3"2 15'4"4 17'8"3 20'1"5 22'6"8 I' 2'7" 1 1- 2'3"6 1 2'3"6 1" 2'1"10 1 2'3"6 I 2'1"2 1" 2,3"15 I 2'5"3 I" 2'5"3 8X12(**) =4X4 =5X7(**) =3X8 =4X5 =H0510 1113X4(**) A B C D E F G H I J K T -R....,...„,:,..,....„..„,...... ,..,:.......::,.....,...„8„,.&u.......„....,...„....*„.____177.....„.. ___„.....................:,.............41 r ip_fi L. :11 90 1 10'1"2 V I.. 1 T S R Q P O N M L 1113X4(**) 1116X10(**) =4X4 =8X8(**) =4X5 =5X5 =5X5 =10X 12(**) I~2' 1 20'6"8 1 2'1" 1 2'5'14 1 236 I- 236 I- 2614 1 236 I_ 236 I- 2111 1 253 I 21 1'8"4 1 6'3"2 8'6"9 10'9"15 13'4"14 15'8 4 17'11"11 20'1"5 22'6"8 3'9"4 Loading Criteria(par) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.321 F 765 360 U 9159 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.627 F 391 327 L 2057 /- /- /- /- /- BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.071 A - - U Min Brg Width Req= 4.8 Des Ld: 62.00 EXP:NA HORZ(TL): 0.139 A - - L Min Brg Width Req= - NCBCLL:W.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearing U Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.897 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.940 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.989 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 132 -10 F-G 0 -5452 I:NA GCpi:NA Plate Type(s): B-C 0-5714 G-H 0 -5420 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01A.0723.13 C-D 0-6456 H-I 0 -4151 Lumber Purlins D-E 0-6244 I-J 0 -3024 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins E-F 0-5458 J-K 0 8 Top chord 2x4 SP M-30 to laterally brace chords as follows: Bot chord 2x6 SP SS Dense Chord Spacing(in oc) Start(ft) End(ft) Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3:W4 2x4 SP SS: TC 24 0.00 22.54 Chords Tens.Comp. Chords Tens. Comp. BC 120 0.00 22.54 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers V-U 3 0 Q-P 5452 0 approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. U-T 967 -10 P-0 4324 0 The TC of this truss shall be braced with attached T-S 5821 0 0-N 3195 0 Nailnote spans at 24"oc in lieu of structural sheathing. S-R 6456 0 N-M 1747 0 Nail Schedule:0.131"x3",min.nails R-Q 6184 0 M-L 1747 0 Top Chord:1 Row @ 9.75"o.c. Additional Notes Bot Chord:1 Row @ 3.50"o.c. Webs 1 Row @ 4"o.c. Truss must be installed as shown with top chord up. Maximum Web Forces Per Ply(lbs) Use equal spacing between rows and stagger nails The maximum concentrated load is 7822# Webs Tens Comp. Webs Tens. Comp. in each row to avoid splitting. The overall height of this truss excluding overhang is A-V 0 -119 Q-F 48 -42 4"o.c.spacing of nails perpendicular and parallel to 1-8-0. A-U 8 -157 G-P 0 -291 grain required in area over bearings greater than 4" U-B 0-4345 P-H 1306 0 Special Loads B-T 6095 0 H-O 0 -785 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) T-C 0 -486 O-I 1139 0 TC-From 264 plf at 0.00 to 264 plf at 4.00 C-S 757 0 I-N 0 780 TC-From 114 plf at 4.00 to 114 plf at 22.54 S-D 4 -191 N-J 1491 0 BC-From 10 plf at 0.00 to 10 plf at 22.54 D-R 278 -253 J-M 32 0 BC-7821 lb Conc.Load at 4.19 R-E 273 -126 J-L 0 -1970 E-Q 158 -865 K-L 0 -66 Plating Notes All plates are 3X4 except as noted. (**)7 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Hangers/lies (J)Hanger Support Required,by others NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 6f) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PEE No.Michael 08391owski PE No 5854gson FE No. Murray7457PE No.77769311 71613 Ply:3 SEAN:17401/T99/FLAT Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FG06 Wgt:245.7 lbs ... / ... 09/25/17 241 4'1"11 _I_ 5'8'8 I 7.3"5 5 I 9'0"15 I 11 5 2'4"1 1'9"9 1'6"13 1 6 13 1'9"9 2'4"1 --=66X10("") -----1(7 C7 =3X8 III ff4 =iXB = X7 =6X10(6) 4 ❑ 2:::>..W1W1 - - __/, 101 2 M 'I K O 1113X8 =6X12 =5X7 =4X10 sadX7 =6X12 1113X1 1'10"11'10"1 2'0"5 2'0"5 1'10"1 1'10"1 r 1.10"1 -I 3'8"3 I 5'8"8 I 7'8"13 9'6"15 I 11'5" i Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Detl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.084 0 999 360 N 7617 /- /- /- /- /- BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.179 D 765 240 H 7821 /- /- /- /- /- BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.020 A - - N Min Brg Width Req= - Des Ld: 62.00 EXP:NA HORZ(TL):0.043 A - - H Min Brg Width Req= - NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.364 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.535 Chords Tens.Comp. Chords Tens. Comp. Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.520 A-B 0-3291 D-E 0 -6180 C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber. B-C 0-5367 E-F 0 -5391 I:NA GCpi:NA Plate Type(s): C-D 0-6180 F-G 0 -3317 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 Lumber Purlins Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Chords Tens.Comp. Chords Tens. Comp. Top chord 2x6 SP SS Dense to laterally brace chords as follows: N-M 56 0 K-J 5713 0 Bot chord 2x6 SP SS Dense Chord Spacing(in oc) Start(ft) End(ft) M-L 3987 0 J-I 4015 0 Webs 2x6 SF'SS Dense:W2,W12 2x4 SP SS: TC 24 0.00 11.42 L-K 5694 0 I-H 59 0 :W4,W10 2x4 SP#2: BC 120 0.00 11.42 :W6,W8 2x4 SP#3: Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values approved 1/30/2013 by ALSC The TC of this truss shall be braced with attached Webs Tens.Comp. Webs Tens. Comp. spans at 24"oc in lieu of structural sheathing. q_N 0-2415 K-E 586 0 Nailnote A-M 3825 0 E-J 0 -894 Additional Notes Nail Schedule:0.131"x3",min.nails Truss must be installed as shown with top chord up. M-B 0-1935 J-F 1840 0 Top Chord:2 Rows @ 4.50"o.c.(Each Row) B-L 1842 0 F-I 0 -1937 Bot Chord:2 Rows @ 5.00"o.c.(Each Row) The overall height of this truss excluding overhang is L-C 0 -909 I-G 3852 0 Webs :1 Row @ 4"o.c. 1-7-12. C-K 610 0 G-H 0 -2434 Repeat nailing as each layer is applied.Use equal D-K 0 -381 spacing between rows and stagger nails in each row to avoid splitting. Special Loads ---(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC-From 849 plf at 0.00 to 859 plf at 11.42 BC-From 5 plf at 0.00 to 5 plf at 11.42 BC-1126 lb Conc.Load at 1.90,3.90,5.90,7.90 9.90 Plating Notes (")2 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Hangers/Ties (J)Hanger Support Required,by others NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer 1q*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE No.l 08391owski PE No. 8544son PE No.MurrayDerek B7457Adam K PE No.77769311 APEX 71613 Ply:2 SEQN:17286/T3/COMN Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FG07 Wgt:123.2 lbs ... / ... 09/25/17 3'11"7 7'0"1 9'10"14 12'11"8 H 3'11"7 3'0"10 I 2'10"14 3'0"10 12 1113X4 01113X4 =6X6(**)(I) (j 4 C4X8 D T2 E F TT TW Cs1 4X4(**) B 1*--_ 4�3 A PP .-I 1_,$_10,1"2 a. J 1 H r G 1113X4 =3X4 =4X10 1113X4(**) 4'1"3272 3714 2'9"6 H 1I'6"8 A I 4'1"3 6'10"5 10'2"2 12'11"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl LA Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.096 D 999 360 B 1605 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.267 D 576 240 G 2291 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.018 C - - B Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL):0.049 C - - G Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings B&G Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.868 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.762 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.643 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 27 0 D-E 0 -2162 I:NA GCpi:NA Plate Type(s): B-C 0-1717 E-F 0 -2074 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 0-2123 Lumber Purlins Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2:T2 2x4 SP#1: to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#1 Chord Spacing(in oc) Start(ft) End(ft) B-J 1597 0 H 2162 0 Webs 2x4 SP#3:W5 2x4 SP#2: TC 24 1.50 12.96 J-I 1602 0 H-G 10 0 BC 120 0.15 12.96 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Maximum Web Forces Per Ply(lbs) Nailnote Webs Tens.Comp. Webs Tens. Comp. Additional Notes Nail Schedule:0.131"x3",min.nails The overall height of this truss excluding overhang is C-J 72 0 E-H 0 -828 Top Chord:1 Row @ 6.25"o.c. t-8-0. C-I 575 0 H-F 2277 0 Bot Chord:1 Row @12.00"o.c. I-D 0 -374 F-G 0 -1174 Webs :1 Row @ 4"o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC-From 116 plf at -1.54 to 116 plf at 3.95 TC-From 116 plf at 3.95 to 116 plf at 5.67 TC-From 403 plf at 5.67 to 403 plf at 12.96 BC-From 10 plf at 0.00 to 10 plf at 12.96 Plating Notes (I)-plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Tolerance,and/or zero Positioning Tolerance. (**)3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. NOTES: It- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. 6111) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer fi*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 T�.yTG APEX Tru el l o u se PE o.160839 KozlowskiJeffrey P PE No. 8544son PE No.71457y Adam Russell PE No.77693 71613 Ply:2 SEQN:17410/T84/MONO Jo&Brian Adcock Residence Qty: 1 FROM: DRW FG08 Wgt:131.6 lbs ... / _ 09/25/17 2'10"15 5'8"1 8'5"4 11'4"2 2'10"15 I 2.9"3 '+" 2.9"3 4- 2,10„15 III 3 (4(**) =6X 2(**) III X4 =6 2(**) III 3Xi **) T HHI UD CNI ____-.---- ----4- W8 I I H L • 10'1"2 -E0- 1114X5 =4X8 1113X8 ' FK 6X6(**)(I) =6X6(**)(I) 2'10"15 2'9"3 2'9"3 2'10"15 2'10"15 sl 5'8"1 -1' 8'5"4 + 11'4"2 i Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.108 C 999 360 J 3614 /- /- /- /- /4.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.196 C 693 240 K 4778 /- /- /- /- /10.0 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.020 A - - J Min Brg Width Req= 1.9 Des Ld: 62.00 EXP:NA HORZ(TL): 0.037 A - - K Min Brg Width Req= 2.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings J&K Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.753 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.593 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.648 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-8 0 -18 C-D 0 -4001 I:NA GCpi:NA Plate Type(s): B-C 0-4001 D-E 0 -21 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 Lumber Purlins Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2 to laterally brace chords as follows: J-I 3176 0 H-G 3400 0 Bot chord 2x6 SP SS Dense Chord Spacing(in oc) Start(ft) End(ft) I-H 3176 0 G-F 3400 0 Webs 2x4 SP#3:W2 2x4 SP#2: TC 24 0.00 11.35 :W8 2x4 SP#1: BC 120 0.00 11.35 Apply purlins to any chords above or below fillers Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values at 24"OC unless shown otherwise above. Webs Tens.Comp. Webs Tens. Comp. approved 1/30/2013 by ALSC The TC of this truss shall be braced with attached spans at 24"oc in lieu of structural sheathing. A-J 0 -49 H-D 662 0 Nailnote g' J-B 0-3446 D-G 1114 0 Nail Schedule:0.131"x3",min.nails Additional Notes B-I 914 0 D-F 0 -3687 Top Chord:1 Row @12.00"o.c. Truss must be installed as shown with top chord up. B-H 909 0 E-F 0 -50 Bot Chord:2 Rows @ 3.50"o.c.(Each Row) C-H 0 -54 Webs :1 Row @ 4"o.c. The overall height of this truss excluding overhang is Use equal spacing between rows and stagger nails 1-7-12. in each row to avoid splitting. Special Loads ----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC-From 57 plf at 0.00 to 57 plf at 11.35 BC-From 5 plf at 0.00 to 5 plf at 11.35 BC-1126 lb Conc.Load at 1.02,3.02,5.02,7.02 9.02 BC-2057 lb Conc.Load at 10.67 Plating Notes (I)-plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Tolerance,and/or zero Positioning Tolerance. (")6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. NOTES: \' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11.1.I 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PE No.l 6083911 Jeffrey P PE No.58544 Ameson Derek PE No 71457y RussellAdam K PE No.77693 71613 Ply:3 SEQN:17384/T66/FLAT . Jo&Brian Adcock Residence Qty: 1 FROM DRW: FG09 Wgt:319.2 lbs . / 09/25/17 2'3" 4'3"14 64"11 8'3"13 10'4"11 12'3"13 14'4"10 16'9" 2'3" I 2'0"14 2'0"14 I 1'11"2 I 2'0"14 I 1'11"2 I 2'0"14 I 2'4"6 i 6X6(**) =5X5(**) A B C D E F G H T2 I ........7:7>11„...„.......A ***N'...... .......''...Z 0 0 E� 10'1"2 R C P 0 N M L K 1J T 1113X4(**) ss X8 5X5(**) 1113X4(**) H- 1'1 1 8 1 14'9"8 i , 1'11" 21"6 I 2.0"14 2'0"14 2'4"6 I 2014 2'0" 4 2'014 I " " I " I " I " I "111 406 613 821 10'6"7 1275 1482 169 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.041 A 570 360 Q 6919 /- /- /- /- /3.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.090 A 259 240 J 686 /272 /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL):-0.021 A - - 0 Min Brg Width Req= 2.5 Des Ld: 62.00 EXP:NA . HORZ(TL):-0.048 A - - J Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings Q&J Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.826 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.982 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.613 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 2034 0 E-F 772 -393 I:NA GCpi:NA Plate Type(s): B-C 1677 0 F-G 753 -393 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 1307 -58 G-H 339 -432 Lumber Purlins D-E 795 -377 H-I 158 -276 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP SS:T2 2x4 SP#2: Bot chord 2x4 SP#2 Chord Spacing(in oc) Start(ft) End(ft) Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 TC 24 0.00 16.75 R-Q 9 0 N-M 393 -772 BC 111 0.00 16.75 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers Q-P 0-1904 M-L 445 -379 approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. P-0 0-1638 L-K 315 -180 The TC of this truss shall be braced with attached O-N 111 -1244 K-J 2 0 Nailnote spans at 24"oc in lieu of structural sheathing. Nail Schedule:0.131"x3",min.nails Maximum Web Forces Per Ply(lbs) Top Chord:1 Row @ 3.25"o.c. Additional Notes Webs Tens.Comp. Webs Tens. Comp. Bot Chord:1 Row @12.00"o.c. Negative reaction(s)of-272#MAX.from a non-wind Webs :1 Row @ 4"o.c. A-R 0 -30 N-E 0 -288 load case requires uplift connection.See MaximumRe eat nailingas each layer is applied.Use equal Reactions. A-Q 0-2496 F-M 178 -9 spacing between rows and stagger nails in each row Q-B 0 -830 M-G 0 -487 to avoid splitting. Truss must be installed as shown with top chord up. B-P 543 0 G-L 189 -64 Special Loads The overall height of this truss excluding overhang is P-C 0 -352 L-H 149 -201 1-8-0. C-0 590 0 H-K 106 -185 -----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) 0-D 0 -413 K-I 329 -190 TC-From 114 plf at 0.00 to 114 plf at 16.75 D-N 711 0 I-J 94 -222 BC-From 10 plf at 0.00 to 10 plf at 16.75 TC-5161 lb Conc.Load at 0.29 Plating Notes All plates are 3X4 except as noted. (**)5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. • NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Tri-1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ,*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PE Noel K3oozlowski PE No.585.44son o58544son FE No. Murray74PE No.o7 69311 71613 Ply:3 SEQN:17394/T91/COMN Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FG10 Wgt:317.1 lbs ... / ... 09/25/17 3'8" , 11"12 10'391 11 13'9"5 17'1"4 20'5" 3'8" I 3'3"12 I 3'3"15 I 3'5"11 I 3'3"15 I 3'3"12 12 4 p w6X10('") w5X5("") 1113X4 1113X4 =5X5 =6X6(") DT 1"2 C D E F G H T _ n TI v � co =3X8(A1)B _ ^ in =" 423 A L 1 N rh10'1'2 ' • N M L K J pEIP 1113X4 '' 4X5 =3X4 m8X8(") E4X8 1113X4(") h-1'6"8 1 3'9"12 I 2'10"8 '11"12 3'9"12 6'8"4 I 3'5"11 3'9"3 3'6"3 I I 2 10'1"15 13'11"1 17'5"4 20'5" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.182 E 999 360 O 3083 /- /- I- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.423 E 575 324 P 2768 /- /- /- /- /5.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.028 C - - 0 Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL): 0.065 C - - P Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings 0&P Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.306 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.505 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.614 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 18 0 E-F 0 -2930 I:NA GCpi:NA Plate Type(s): B-C 0-2597 F-G 0 -2907 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 0-3455 G-H 0 -1536 Lumber Purlins D-E 0-2929 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Top chord 2x4 SP M-31 to laterally brace chords as follows: Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x6 SP SS Dense Chord Spacing(in oc) Start(ft) End(ft) Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3:W9 2x4 SP#2: TC 24 1.50 20.42 B-N 2442 0 L-K 2930 0 BC 120 0.15 20.42 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers N-M 2440 0 K-J 1713 0 approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. M-L 3523 0 J-I 16 0 Nailnote Additional Notes Maximum Web Forces Per Ply(lbs) Nail Schedule:0.131"x3",min.nails The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. Top Chord:1 Row @ 3.75"o.c. 1-8-0. Bot Chord:1 Row @12.00"o.c. C-N 33 -13 F-K 0 -204 Webs :1 Row @ 4"o.c. C-M 1092 0 K-G 1289 0 Repeat nailing as each layer is applied.Use equal M-D 0 -331 G-J 0 -801 spacing between rows and stagger nails in each row D-L 38 -642 J-H 1653 0 to avoid splitting. L-E 0 -24 H-I 0 -873 Special Loads (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC-From 116 plf at -1.54 to 116 plf at 3.67 TC-From 434 plf at 3.67 to 434 plf at 6.83 TC-From 116 plf at 6.83 to 116 plf at 17.25 TC-From 434 plf at 17.25 to 434 plf at 20.42 BC-From 10 plf at 0.00 to 10 plf at 20.42 TC- 273 lb Conc.Load at 3.67 TC- 822 lb Conc.Load at 6.83 Plating Notes (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PE Noel Gg 3ogzlowski Jeffrey No.58544 on PE No.71457y PE No.77769311 71613 Ply:3 'SEQN:17349/T85/COMN Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FG11 Wgt:344.4lbs / ... 09/25/17 5'1" I 6'10" I 8'9"11 I 11'0"13 I 13'5"12 I 15'6"11 I 17'9"13 I 20'5" 5'1" 1'9" 1'11"11 2'3"3 2'4"15 2'0"15 2'3"3 2'7"3 T 4 p 613X4(.,)D .. .. 4X8C 0 DT_1. -4X5 =3X4 1113X4 =4X8 =6X6(") T F G H =3X81 J K 93 ' _ I Tcn =4X5(..)9 = �t� - - � W1. PM .co- t', A 0,-"IP. rR `i ■ 1 m10'1"2 S R Q P 0 N M lL I W =4X5 =5X5 m3X4 mH0514(") =3X8 =4X8 =5X7 1113X4(") �-1'6"8 1 5'1" 1'9" 2'3"3 2'1"7 2'5"7 2'3"3 2'2"11 2'3"3 5'1" I 6'10" I 9'1"3 I 11'2"9 I 13,8" I 15'11"3 I 18'1"13 I 20'5" 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.217 G 999 360 B 2990 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.570 G 426 324 L 3419 /- /- /- /- /5.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.052 E - - B Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL): 0.137 E - - L Min Brg Width Req= 1.5 NCBCLL:W.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings B&L Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.431 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.732 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.601 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 18 0 G-H 0 -4697 I:NA GCpi:NA Plate Type(s): B-C 0-2432 H-I 0 -4639 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01A.0723.13 C-E 0 -165 I-J 0 -3384 Lumber Purlins D-F 0-3364 J-K 0 -1833 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins F-G 0-4656 Top chord 2x4 SP M-31 to laterally brace chords as follows: Bot chord 2x4 SP M-31 Chord Spacing(in oc) Start(ft) End(ft) Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3:W4 2x4 SP M-31: TC 24 -1.50 20.42 Chords Tens.Comp. Chords Tens. Comp. :W12,W 14 2x4 SP#2: BC 120 0.15 20.42 Apply purlins to any chords above or below fillers B-S 2273 0 P-0 4697 0 Lumber value set"13B"uses design values at 24"OC unless shown otherwise above. S-R 3254 0 0-N 3594 0 approved 1/30/2013 by ALSC R-0 4635 0 N-M 2066 0 Nailnote Q-P 4715 0 M-L 7 0 Nail Schedule:0.131"x3",min.nails Maximum Web Forces Per Ply(lbs) Top Chord:1 Row @ 4.00"o.c. Webs Tens.Comp. Webs Tens. Bot Chord:1 Row @12.00"o.c. Comp. Webs :1 Row @ 4"o.c. C-S 820 0 G-P 0 -160 Repeat nailing as each layer is applied.Use equal C-D 0-2153 H-0 0 -537 spacing between rows and stagger nails in each row S-D 0-1289 O-I 1262 0 to avoid splitting. D-E 3 0 I-N 0 -984 Special Loads D-R 928 0 N-J 1592 0 R-F 0-1586 J-M 0 -1093 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) F-Q 101 0 M-K 2119 0 TC-From 116 plf at -1.54 to 116 plf at 6.83 Q_G 33 71 K-L 0 -1122 TC-From 468 plf at 6.83 to 468 plf at 17.25 TC-From 116 plf at 17.25 to 116 plf at 20.42 BC-From 10 plf at 0.00 to 10 plf at 20.42 Plating Notes (")6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Additional Notes The overall height of this truss excluding overhang is 2-7-8. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. 6F1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fiV\ Tru eHo use E No.Michael 60839 G Kozlowski 039lowski Jeffrey No. 854gson FE No. Murray7457PE No.Russell Derek BAPEX 71613 Ply:1 SEQN:20100/T75/SY42 Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: FGE01 Wgt:47.6 lbs ... / ... 09/25/17 H 1'2"8--I---1'4,- (TYP) A B C D E F G T38 P._;-1 - - - LH co I1 - .- - - - F 0 101"2 III 3X3 N M L K J 1113X3 F 8' F 8' -1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or"=PLF TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.000 G 999 360 I' 120 /- /- /- /- /96.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.001 G 999 240 0 Min Brg Width Req= - BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.000 G - - Bearing 0 Fcperp=565psi. Des Ld: 62.00 EXP:NA HORZ(TL): 0.000 G - - NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Maximum Top Chord Forces Per Ply(lbs) Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.104 Chords Tens.Comp. Chords Tens. Comp. Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.018 A-B 0 0 D-E 0 0 Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.036 B-C 0 0 E-F 0 0 C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: C-D 0 0 F-G 0 0 I:NA GCpi:NA Plate Type(s): Wind Duration:NA WAVE VIEW Ver:17.01.01.0630.10 Maximum Bot Chord Forces Per Ply(lbs) Lumber Additional Notes Chords Tens.Comp. Chords Tens. Comp. Value Set:13B(Effective 6/1/2013) Truss must be installed as shown with top chord up. O-N 0 0 L-K 0 0 Top chord 4x2 SP#2 The overall height of this truss excluding overhang is N-M 0 0 K-J 0 0 Bot chord 4x2 SP#2 1-8-0. M-L 0 0 J-I 0 0 Webs 4x2 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Bracing P-O 0 -9 G-I 0 -54 Sheathing is required for any longitudinal(drag) A-0 0 -54 I-H 0 -9 forces.All connections to be designed by the building designer. Maximum Gable Forces Per Ply(lbs) Fasten rated sheathing to one face of this frame. Gables Tens.Comp. Gables Tens. Comp. Plating Notes B-N 0 -153 E-K 0 -152 All plates are 1.5X3 except as noted. C-M 0 -152 F-J 0 153 D-L 0 -152 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.25 7.75 BC 90 0.25 7.75 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. End Vertical Attachment Attach notched end vertical(s)to next end vertical using(3)qty.10d box or(0.128"x3"min)gun nails,or (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire staples,through wide face;or(3)qty.16-Gauge,1" Crown(minimum),1-1/2"length wire staples on each narrow face. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, be used in conjunction with the architectural plans during installation. 611'} 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 _ APEX �+ Michael G KozlowskiTJeffrey P Arneson Derek B Murray Adam K Russell rue 0 U ce PE No.60839 PE No 58544 PE No 71457 PE No.77693 71613 Ply:1 SEQN:20097/T88/SY42 • Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: FGE02 Wgt:19.6 lbs ... / ... 09/25/17 H8"4"I Fad 3' A B C T I 1111111 D 1 E ■ n I\ 10'1'2 Pir \I G F E 1113X3 1113X3 2' F 2' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs),or*=PLF TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.000 C 999 360 E* 110 /- /- /- /- /24.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.001 C 999 240 G Min Brg Width Req= - BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.000 C - - Bearing G Fcperp=565psi. Des Ld: 62.00 EXP:NA HORZ(TL): 0.000 C - - NCBCLL: W.00 Mean Height:NA ft Code/Misc Criteria Creep Factor 1.5 Maximum Top Chord Forces Per Ply(lbs) Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.046 Chords Tens.Comp. Chords Tens. Comp. Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.007 A-B 0 0 B-C 0 0 Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.010 C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Bot Chord Forces Per Ply(lbs) I:NA GCpi:NA Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:NA WAVE VIEW Ver:17.01.01.0630.10 Lumber Additional Notes G-F 0 0 F-E 0 0 Value Set:13B(Effective 6/1/2013) Truss must be installed as shown with top chord up. Maximum Web Forces Per Ply(lbs) Top chord 4x2 SP#2 The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. Bot chord 4x2 SP#2 1-8-0. Webs 4x2 SP#3 H-G 0 -9 C-E 0 -41 Lumber value set"13B"uses design values A-G 0 -41 E-D 0 -9 approved 1/30/2013 by ALSC Bracing Maximum Gable Forces Per Ply(lbs) Gables Tens.Comp. Fasten rated sheathing to one face of this frame. B-F 0 -106 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.25 1.75 BC 18 0.25 1.75 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. End Vertical Attachment Attach notched end vertical(s)to next end vertical using(3)qty.10d box or(0.128"x3"min)gun nails,or (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire staples,through wide face;or(3)qty.16-Gauge,1" Crown(minimum),1-1/2"length wire staples on each narrow face. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 611H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer 7q*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE Noel 08391owskiJeffrey No 58544son PEPE No Murray1457APE No 77769311 71613 Ply:1 SEAN:17215/T95/COMN Jo&Brian Adcock Residence Qty: 10 FROM: DRW: FT01 Wgt:61.6 lbs ... / ... 09/25/17 3'11"7I 7'0"1 . 9'10"14 12'11"8 H -1 3'11"7 3'0"10 2'10"14 3'0"10 12 =4X10(**) 1113X4 OIII 3X4 =6X6(**)(I) 4 p C D T2 E F c - T T zo 3X8(A1)B 44'3 A J 1 I O 10'1"2 J I H r 1 1113X4 =3X4 =4X10 1113X4("") 1'6"8 1 4'1"3 2'9"2 3'3"14 2'9"6 H4'1"3 I 6'10"5 H 10'2"2 I 12'11"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.188 D 816 360 B 1286 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.378 D 406 240 G 1003 /- /- /- /- /3.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.036 C - - B Min Brg Width Req= 1.5 Des Ld: 62.00 EXP:NA HORZ(TL): 0.072 C - - G Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings B&G Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.998 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.895 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.700 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 55 0 D-E 0 -2314 I:NA GCpi:NA Plate Type(s): B-C 0-2532 E-F 0 -2239 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 0-2284 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2:T2 2x4 SP SS: 1-8-0. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP SS B-J 2344 0 I-H 2314 0 Webs 2x4 SP#3:W5 2x4 SP#2: J-I 2358 0 H-G 0 -5 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. Special Loads -----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) C-J 178 0 E-H 0 -704 TC-From 116 plf at -1.54 to 116 plf at 3.95 C-I 0 -129 H-F 2482 0 TC-From 116 plf at 3.95 to 116 plf at 12.96 I-D 0 -287 F-G 0 -1100 BC-From 10 plf at 0.00 to 10 plf at 12.96 TC- 485 lb Conc.Load at 5.67 Plating Notes (I)-plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Tolerance,and/or zero Positioning Tolerance. (**)3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 12.96 BC 75 0.15 12.96 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Tr14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 _ APEX Tru eHo use PE No.160839Kozlowski PE No 58544son ay PE No 71457 Adam K 11 PE No.77693 71613 Ply:1 SEAN:17369/T77/COMN " Jo&Brian Adcock Residence Qty: 4 FROM: DRW: FT02 Wgt:116.9 lbs ... / ... 09/25/17 3'8" I 6'3"11 I 8715 I 10'10"6 I 132"10 I 1551 I 17'8"13 I 20'5" 3'8" 2'7"11 2'4"3 2'2"7 2'4 3 2'2"7 2'3"11 2'8"3 12 4 p =3X4 =3X4 1113X4 1113X4 =5X7(") 6X6(")(1) DT 1"2 =_6X1C2(")(I) D E F G H m4X81 T3 J T v =4X5 C1 �\ --1 T I in tr) S_ =3X8(C1)B _L i� A � LJ I N 10'1"2 5 R Q P 0 N M L rEKT 1113X4 =4X4 =H1010(")(I) =3X4 -4X8 =4X8 =4X10 1114X4(") „ 39 12 I 22"7 I 2'4"3 I 2'4"3 I 2'8"3 I 2,4"3 I 2,5"3 I 2'2"11 1 I-169 3'9"12 6'0"3 8'4"7 10'810 13'4"14 15'9"1 18'2"5 20'5" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Cts NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.338 0 720 360 S 2352 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.659 0 369 324 T 1452 /- /- /- /- /5.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.055 C - - S Min Brg Width Req= 2.4 Des Ld: 62.00 EXP:NA HORZ(TL):0.107 C - - T Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings S&T Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.656 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.864 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.828 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 55 0 F-G 0 -5739 I:NA GCpi:NA Plate Type(s): B-C 0-5484 G-H 0 -5689 Wind Duration:NA WAVE,HS VIEW Ver:17.01.01A.0723.13 C-D 0-5919 H-I 0 -4029 Lumber Additional Notes D-E 0-6301 I-J 0 -2272 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is E-F 0-5730 Top chord 2x4 SP M-31:T3 2x4 SP M-30: 1-8-0. Bot chord 2x6 SP SS Dense Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3:W13 2x4 SP#2: Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values B-R 5126 0 O-N 5739 0 approved 1/30/2013 by ALSC R-Q 5117 0 N-M 4269 0 Q-P 5988 0 M-L 2555 0 Special Loads P-O 6297 0 L-K 12 0 ----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC-From 116 plf at -1.54 to 116 plf at 3.67 Maximum Web Forces Per Ply(lbs) TC-From 116 plf at 3.67 to 116 plf at 20.42 Webs Tens.Comp. Webs Tens. Comp. BC-From 10 plf at 0.00 to 10 plf at 20.42 TC-1062 lb Conc.Load at 3.67 C-R 0 -78 G-N 0 -446 Plating Notes C-Q 891 0 N-H 1676 0 Q-D 0 -379 H-M 0 -1092 (I)-plates so marked were sized using 0% D-P 370 0 M-I 1740 0 Fabrication Tolerance, 0 degrees Rotational P-E 185 0 I-L 0 -1285 Tolerance,and/or zero Positioning Tolerance. E-0 0 -669 L-J 2578 0 (")5 plate(s)require special positioning.Refer to O-F 59 -77 J-K 0 -1380 scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 20.42 BC 120 0.15 20.42 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. � � (111'FI 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer %f-/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse E No.08391owski PE No.58544son PE No Murray7457PE No Russell Derek BAPEX 71613 Ply:2 SEAN:17374/T1/COMN Jo&Brian Adcock Residence Qty: 1 FROM: DRW: FT03 Wgt:233.8 lbs ... / ... 09/25/17 3'8" I 6'3"11 I 8'7"15 I 10'10"6 I 13'2"10 I 15'5"1 , 17'9"5 , 20'5" 3'8" 2711 2'4"3 2'2"7 2'4"3 2'2"7 2'4"3 2'7"11 12 4 L.....-- DT DT 1"2 =6X112(") =3X4 -3X4 1113X4 1113X4 -5X5(") -4X5 \ E F G H I =5X5 J I 84X4(.. \\ 1 \ !---; W T T =4X4(«) _ _ <y3 A J 1 N 10'1"2 R Q P 0 N M L p*KT 1 1113X4 E3X4 =8X8(") 3X4 =4X5 =4X5 =5X5 1113X4(") 3'912 22"7 2'4"3 2'4"3 2711 2'4"3 2'4"3 2'4"3 3'9"12 I 6'0"3 I 8'4"7 I 10'8"10 I 13'4"6 I 15'8"9 18'0"13 I 20'5" 1 �-1'6"8 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.215 0 999 360 S 3263 /- /- /- /- /5.5 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.416 0 585 324 T 1644 /- /- /- /- /5.5 BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.036 C - - S Min Brg Width Req= 1.7 Des Ld: 62.00 EXP:NA HORZ(TL): 0.070 C - - T Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:1.5 Bearings S&T Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2014 RES Max TC CSI: 0.359 Load Duration:1.00 BCDL:NA psf TPI Std: 2007 Max BC CSI: 0.567 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.493 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 27 0 F-G 0 -3469 I:NA GCpi:NA Plate Type(s): B-C 0-4017 G-H 0 -3439 Wind Duration:NA WAVE VIEW Ver:17.01.01A.0723.13 C-D 0 -4005 H-I 0 -2345 Lumber Purlins D-E 0 -4023 I-J 0 -1305 E-F 0 -3470 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Top chord 2x4 SP M-31 to laterally brace chords as follows: Bot chord 2x6 SP SS Dense Chord Spacing(in oc) Start(ft) End(ft) Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3:W9,W13 2x4 SP#2: TC 24 -1.50 20.42 Chords Tens.Comp. Chords Tens. Comp. BC 120 0.15 20.42 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers B-R 3764 0 0-N 3469 0 approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. R-Q 3753 0 N-M 2494 0 Q-P 4009 0 M-L 1467 0 Nailnote P-O 3991 0 L-K 6 0 Nail Schedule:0.131"x3",min.nails Top Chord:1 Row @ 7.75"o.c. Maximum Web Forces Per Ply(lbs) Bot Chord:1 Row @12.00"o.c. Webs Tens.Comp. Webs Tens. Comp. Webs :1 Row @ 4"o.c. Use equal spacing between rows and stagger nails C-R 46 -97 G-N 0 -268 in each row to avoid splitting. C-Q 316 0 N-H 1115 0 Special Loads Q-D 0 -125 H-M 0 -677 D-P 188 0 M-I 1036 0 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) P-E 143 -37 I-L 0 -735 TC-From 116 plf at -1.54 to 116 plf at 3.67 E-0 0 -616 L-J 1482 0 TC-From 116 plf at 3.67 to 116 plf at 20.42 O-F 6 14 J-K 0 784 BC-From 10 plf at 0.00 to 10 plf at 20.42 TC-2164 lb Conc.Load at 3.67 Plating Notes ('")6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Additional Notes The overall height of this truss excluding overhang is 1-8-0. NOTES: Ir- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE NoMichael l 0 39lowski effrey P PE No. 854gson Derek BPE No 71457y usse PE No Adam K8769311 APEX 71613 Ply:1 SEQN:19876/T31/HIP_ Jo&Brian Adcock Residence Qty: 2 FROM:KS DRW: HJO2 Wgt:11.2 lbs ... / ... 09/25/17 12 C 4.24 F - " T 21'10"10 N 3X4(A1) Bco A N- 4"7 _ 020'11" ►� A 1 D 7 2'6"5 H 2'2"3 1i 2'6"5 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 277 /138 /168 /- /67 /4.2 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 24 /11 /25 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - C 20 /24 /23 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.002 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:21.35 ft Code/Misc Criteria Creep Factor 1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.661 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.161 C Min Brg Width Req= - MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 42 0 B-C 12 -29 Value Set:13B(Effective 6/1/2013) Tap chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.13 2.53 BC 29 0.15 2.53 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 1-3-2. NOTES: r 6'1{ 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03. should be used in conjunction with the architectural plans during installation. 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ TrueHouse PE Noel 60839 PE Jeffrey 58544PE No. 1457 PE No son Derek Murray77Adam K 7769311 APEX 71613 Ply:1 SEQN:19882/T64/HIP_ Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: HJO4 Wgt:21.0 lbs ... / ... 09/25/17 T----E°-22'11"6 12 4.24 N � 3X4(A1) B '47 20'11" A : p 5'6"6 2r2rr3 11 5'6"6 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeIUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 177 /161 /- /- /- /4.2 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 72 /13 /- /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.007 D - - C 78 /78 /- /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL):0.008 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:21.88 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.266 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.211 C Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) G 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 21 -13 B-C 37 -26 Value Set:138(Effective 6/1/2013) Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Chords Tens.Comp. Lumber value set"136"uses design values B-D 0 0 approved 1/30/2013 by ALSC Special Loads ----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 0 plf at -2.18 to 55 plf at 0.00 TC-From 2 plf at 0.00 to 2 plf at 5.53 BC-From 0 plf at -2.18 to 4 plf at 0.00 BC-From 2 plf at 0.00 to 2 plf at 5.53 TC- -30 lb Conc.Load at 1.46 TC- 109 lb Conc.Load at 4.29 BC- 7 lb Conc.Load at 1.46 BC- 74 lb Conc.Load at 4.29 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.13 5.53 BC 65 0.15 5.53 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Additional Notes The overall height of this truss excluding overhang is 2-3-14. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE No.Michael K3oozlowski effrey P Arne PE No.58544son o58544son Derek B PE No 714Mu57y Adam K PE No 7 69311 APEX 71613 Ply:1 SEQN:19870/T39/HIP_ Jo&Brian Adcock Residence Qty:4 FROM:KS DRW: HJO7 Wgt:40.6 lbs ... / ... 09/25/17 5710 9'9"5 EI-I 4'6"11 H D T T 0 24'5"6 4.24 12 (� =='-- r. ,:r 41 in in to -v 3X4(A1)B T MI 47 1;� 20'11" A =4X4E F H----22"3 1 9'5"11 I3' 9'5"11 9' 5 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.018 F 999 240 B 273 /250 /- /- /- /4.2 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.054 F 999 180 E 284 /121 /- /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.007 F - - D 65 /50 /- /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.024 F - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:22.63 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.457 E Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.942 D Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.229 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Additional Notes A-B 21 -14 C-D 43 -56 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is B-C 355 -420 Top chord 2x4 SP#2 3-9-14. Bot chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values B-F 416 -310 F-E 0 0 approved 1/30/2013 by ALSC Special Loads Maximum Web Forces Per Ply(lbs) -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Webs Tens Comp. TC-From 0 plf at -2.18 to 55 plf at 0.00 C-F 336 -451 TC-From 2 plf at 0.00 to 2 plf at 9.77 BC-From 0 plf at -2.18 to 4 plf at 0.00 BC-From 2 plf at 0.00 to 2 plf at 9.77 TC- -30 lb Conc.Load at 1.46 TC- 109 lb Conc.Load at 4.29 TC- 224 lb Conc.Load at 7.12 BC- 7 lb Conc.Load at 1.46 BC- 74 lb Conc.Load at 4.29 BC- 134 lb Conc.Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord SpacingOn oc) Start(ft) End(ft) TC 24 -2.13 9.77 BC 116 0.15 9.77 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. NOTES: 'V- (1111'1-1) 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 reyAPEX Tru eHo use PE Noel 10 K3oozlowski FE No. 85445on PE No. Murray7457Adam K PE No.Russell 1 693 71613 Ply:1 SEQN:19891/T54/HIP_ Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: HJO7A Wgt:40.6 lbs ... / ... 09/25/17 5'2"10I 9'9"5 F5'2"10 4'6"11 D :l T 24'5"6 4.24 12 3X4 C v Zn _...iiiiiiiiiiiiihib...' ...alisirissisit io m v 3X4(A1)B 11"7 �I t:� 20'11" A -IT, F F-2'2"3 1 95"11 9'5"11 ' 5 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pt NA Ce:NA VERT(LL): 0.019 F 999 240 B 291 /261 /- /- /- /4.2 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.054 F 999 180 E 303 /135 /- /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.008 F - - D 67 /51 /- /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL):0.024 F - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:22.63 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.475 E Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.985 D Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.248 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Additional Notes A-B 21 14 C-D 45 -59 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is B-C 379 -458 Top chord 2x4 SP#2 3-9-14. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values B-F 452 -333 F-E 0 0 approved 1/30/2013 by ALSC Special Loads Maximum Web Forces Per Ply(lbs) -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Webs Tens.Comp. TC-From 0 plf at -2.18 to 55 plf at 0.00 C-F 361 -490 TC-From 2 plf at 0.00 to 2 plf at 9.77 BC-From 0 plf at -2.18 to 4 plf at 0.00 BC-From 2 plf at 0.00 to 2 plf at 9.77 TC- -30 lb Conc.Load at 1.46 TC- 128 lb Conc.Load at 4.29 TC- 235 lb Conc.Load at 7.12 BC- 7 lb Conc.Load at 1.46 BC- 79 lb Conc.Load at 4.29 BC- 138 lb Conc.Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.13 9.77 BC 116 0.15 9.77 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. NOTES: f' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61}{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PE Noel 0391owski PE No.58544 PE No. Murray74PE No.Russell 71613 Ply:1 SEQN:19912/T97/HIP_ Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: HJO7B Wgt:40.6 lbs ... / ... 09/25/17 5'2"10I 9'9"5 -I 5'2"10 4'6"11 D T a)24'5"6 4.24 12 3X4 C I m M io v 3X4(A1)B 77 �I�i 20'11" A =4X4 E F i-2'2"3 1 9'S"11 I3" 9'5"11 9' S Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.018 F 999 240 B 276 /253 /- /- /- /4.2 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.054 F 999 180 E 289 /127 /- /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.007 F - - D 68 /52 I- I- l- /1.5 Des Ld: 32.00 EXP:C HORZ(TL):0.024 F - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:22.63 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.479 E Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.957 D Min Brg Width Req= - MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI:0.234 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Additional Notes A-B 21 14 C-D 44 58 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is B-C 363 -430 Top chord 2x4 SP#2 3-9-14. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values B-F 426 -318 F-E 0 0 approved 1/30/2013 by ALSC Special Loads Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 0 plf at -2.18 to 55 plf at 0.00 C-F 345 -462 TC-From 2 plf at 0.00 to 2 plf at 9.77 BC-From 0 plf at -2.18 to 4 plf at 0.00 BC-From 2 plf at 0.00 to 2 plf at 9.77 TC- -30 lb Conc.Load at 1.46 TC- 109 lb Conc.Load at 4.29 TC- 233 lb Conc.Load at 7.12 BC- 7 lb Conc.Load at 1.46 BC- 74 lb Conc.Load at 4.29 BC- 137 lb Conc.Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.13 9.77 BC 116 0.15 9.77 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. 611'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer i Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE Noel 0 3o�zlowski Jeffrey No.58544son o58544son Pb No.71457y PE No.77769311 71613 Ply:1 SEQN:19903/T51/HIP_ Jo&Brian Adcock Residence Qty: 2 FROM:KS DRW: HJ08 Wgt:12.6 lbs ... / ... 09/25/17 12 C 4.24 .' 1 , 21'11"6 NV [-- 3X4(A1) B ch "7 I i N �� 20'11" A ►m p \/ 2'8"7 2'2"3H 1� 2'8"7 Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 278 /136 /168 /- /61 /4.9 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 27 /10 /24 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.002 D - - C 27 /23 /21 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.002 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:21.38 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.378 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.097 C Min Brg Width Req= - MWFRS Parallel Dist:h/2 to h RepFactors Used:Yes Max Web CSI:0.000 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Camp Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 42 0 B-C 9 -29 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.13 2.70 BC 31 0.15 2.70 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 1-3-14. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH4 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PEMichaeNo.160839lowski effrey P PE No. 8544�n Derek ay PE No.71457y Adam Russell PE No.776 71613 Ply:1 SEAN:20007/T13/HIP_ ' Jo&Brian Adcock Residence Qty: 3 FROM:KS DRW: HJO9 Wgt:40.6 lbs ... / ... 09/25/17 5'4"13I 9'9"5 H 5'4"13 4'4"8 D 2.83 2 0 T 012'57 3X40 co N Co 3X4(A1)B 42 A I CI)10'1"2 4X4(*F-) F H-2'2"3 * 9'6"13 j8 9'6"13 9'�'S Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.029 F 999 240 G 266 /179 /- /- /- /7.0 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.086 F 999 180 E 282 /73 /- /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.008 F - - D 56 /27 /- /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL):0.024 F - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.413 E Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.938 D Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.306 Bearing G Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Wind A-B 15 -7 C-D 19 -39 B-C 295 -587 Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. Top chord SP#2 Additional Notes Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 The overall height of this truss excluding overhang is Lumber value set"13B"uses design values 2-7-13. B-F 585 -272 F-E 0 0 approved 1/30/2013 by ALSC Special Loads Maximum Web Forces Per Ply(lbs) -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Webs Tens.Comp. TC-From 0 plf at -2.18 to 54 plf at 0.00 C-F 284 -611 TC-From 2 plf at 0.00 to 2 plf at 9.77 BC-From 0 plf at -2.18 to 4 plf at 0.00 BC-From 2 plf at 0.00 to 2 plf at 9.77 TC- -25 lb Conc.Load at 1.46 TC- 105 lb Conc.Load at 4.29 TC- 217 lb Conc.Load at 7.12 BC- 3 lb Conc.Load at 1.46 BC- 71 lb Conc.Load at 4.29 BC- 131 lb Conc.Load at 7.12 Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.15 9.77 BC 116 0.15 9.77 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: Nr- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. �\ (1111H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer I�- Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo u se PE Noel GO K3oozlowski FE No.58544son o58544son FE No. Murray74PE No.7 69311 • 71613 Ply:1 SEQN:20022/T80/HIP_ Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: HJ10 Wgt:40.6 lbs ... / ... 09/25/17 5'4"13 I 9'9"5 5'4"13 4'4"8 12D 2.83 T 012'5"7 3X40 t 1 liwimiNummommommimmorm (V 3X4(A1)B 4"3 A 10'1"2 =4X40 F ri �-2'2"3 11'9'6"13 9'6"135 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.021 F 999 240 B 269 /217 /- /- /- /7.8 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.066 F 999 180 E 264 /73 I- /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.007 F - - D 57 /25 /- /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.021 F - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.393 E Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.894 D Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.283 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Wind A-B 15 -7 C-D 19 -37 Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. B C 304 -542 Top chord 2x4 SP#2 Left cantilever is exposed to wind Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Webs 2x4 SP#3 Additional Notes Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values The overall height of this truss excluding overhang is B-F 540 -274 F-E 0 0 approved 1/30/2013 by ALSC 2-7-13. Special Loads Maximum Web Forces Per Ply(lbs) -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Webs Tens Comp. TC-From 0 plf at -2.18 to 54 plf at 0.00 C-F 286 -564 TC-From 2 plf at 0.00 to 2 plf at 9.77 BC-From 0 plf at -2.18 to 4 plf at 0.00 BC-From 2 plf at 0.00 to 2 plf at 9.77 TC- -30 lb Conc.Load at 1.46 TC- 95 lb Conc.Load at 4.29 TC- 210 lb Conc.Load at 7.12 BC- 3 lb Conc.Load at 1.46 BC- 68 lb Conc.Load at 4.29 BC- 128 lb Conc.Load at 7.12 Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.15 9.77 BC 114 0.29 9.77 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (91IFFI'41- 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ,gt/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.Michael 08391owski Jeffrey No.58544son PE No.71457y PE No.77769311 71613 Ply:1 SEQN:20058/T20/HIP_ Jo&Brian Adcock Residence Qty: 2 FROM:KS DRW: HJ12 Wgt:42.0lbs ... / ... 09/25/17 5'4"13I 8'10" I 9'9"5, 5'4" 3 3'5"3I 11"4 E 1113X4 D r, T - O 12'5"7 2.83 p 3X40 M .� HB 9"8 v v N N T 3X4(A1)B 2 A m ;� 1 (M 101012 G F =4X4 l8'6„8 i 8'8"41'1" 2,2„3 8,8„4 � 9'9"5I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TOLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc LJdef L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.011 G 999 240 B 232 /204 /- /- /- /7.8 BOLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.035 G 999 180 G 729 /159 /- /- /- /5.7 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.003 G - - F -241 /241 /2 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.011 G - - E 7 /103 /47 /- /- /1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 Wind reactions based on MWFRS Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.292 B Min Brg Width Req= 1.5 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.581 G Min Brg Width Req= 1.5 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.131 F Min Brg Width Req= - E Min Brg Width Req= - C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Bearings B&G Fcperp=565psi. GCpi:0.18 Plate Type(s): Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Maximum Top Chord Forces Per Ply(lbs) Lumber Additional Notes Chords Tens.Comp. Chords Tens. Comp. Value Set:13B(Effective 6/1/2013) Negative reaction(s)of-241#MAX.from a non-wind A-B 15 -7 C-D 20 -31 Top chord 2x4 SP#2 load case requires uplift connection.See Maximum B-C 241 -371 D-E 11 24 Bot chord 2x4 SP#2 Reactions. Webs 2x4 SP#3 The overall3height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Lumber value set"13B"uses design values Chords Tens.Comp. Chords Tens. Comp. approved 1/30/2013 by ALSC B-G 367 -212 G-F 0 0 Special Loads (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Maximum Web Forces Per Ply(lbs) TC-From 0 plf at -2.18 to 54 plf at 0.00 Webs Tens.Comp. Webs Tens. Comp. TC-From 2 plf at 0.00 to 2 plf at 9.77 BC-From 0 plf at -2.18 to 4 plf at 0.00 C-G 225 -386 D-G 91 -210 BC-From 2 plf at 0.00 to 2 plf at 9.77 TC- -30 lb Conc.Load at 1.46 TC- 95 lb Conc.Load at 4.29 TC- 210 lb Conc.Load at 7.12 BC- 3 lb Conc.Load at 1.46 BC- 68 lb Conc.Load at 4.29 BC- 128 lb Conc.Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.15 9.77 BC 114 0.29 9.77 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Left cantilever is exposed to wind NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Iirli) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court.Suite 402,Jacksonville,FL 32224-904.821.5200 fiV\ APEX TrueHouse PE No Michael 0 391owski PE No 5854gson PE No 71457y APE No 77769311 71613 Ply:1 SEQN:19867/T36/JACK Jo&Brian Adcock Residence Qty: 14 FROM:KS DRW: J01 Wgt:5.6 lbs ... / ... 09/25/17 12 6 ** g �� T 3X4(**) ti 21'5"15 4"7gi, 20'11" ►t V/ A D r 1'6"8 1' Loading Criteria(est) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 219 /101 /176 /- /48 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 3 /18 /18 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.000 D - - C -47 /51 /43 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL):-0.001 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:21.15 ft Code/Mist Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psi Bldg Code: FBC 2014 RES Max TC CSI: 0.567 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.079 C Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Camp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 40 0 B-C 66 -35 Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#3 Chords Tens.Comp. Bot chord 2x4 SP#3 Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 1.00 BC 10 0.15 1.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 0-10-7. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'FI) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ APEX TrueHouse PE Noel 0 3o9zlowski FE No.58544son o58544son PE No.71457y APE No.77769311 71613 Ply:1 SEQN:19873/T40/EJAC • Jo&Brian Adcock Residence Qty: 2 FROM:KS DRW: J02 Wgt..8.4lbs ... / _ 09/25/17 12 C 6 _ ' 1 T dui 21'11"3 MP 3X4(')g o 4"7 A _4)___,1-- 20'11" ►►_� A ►— D I----- 1'6"8 i- 1 10 8 110"8 Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in lac Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 201 /72 /148 /- /53 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 19 /8 /15 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - C 13 /18 /22 /- /- /1.5 Des Ld: 32.00 EXP:C . HORZ(TL):-0.001 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:21.37 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.326 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.062 C Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 40 0 B-C 10 -30 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 1.88 BC 21 0.15 1.88 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 1-3-11. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. (11'}{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer %gf./\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Jeffrey P APEX Tru eHo use PE No. Michael 6G K3oozlowski PE No. 8544son pE No.71457y APE No.7 69311 71613 Ply:1 SEAN:19864/T35/JACK Jo&Brian Adcock Residence Qty: 13 FROM:KS DRW: J03 Wgt:12.6 lbs ... / ... 09/25/17 12 AT 0 22'5"15 6 ti o _ 3X4(**)BZID (V r� 20'11" p.m A D 3' 1 r6rr8 3 , ' i v Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 220 /84 /152 /- /94 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 37 /0 /15 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - C 55 /48 /25 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.002 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:21.65 ft Code 1 Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.570 D Min Brg Width Req= - BCDL:3.0 sf TPI Std: 2007 Max BC CSI: 0.091 C Min Brg Width Req= - Load Duration:1.25 P Bearing B Fcperp=565psi. Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-8 40 0 B-C 24 -75 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 3.00 BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 1-10-7. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03 should be used in conjunction with the architectural plans during installation. (Tr H 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No 08391owski Jeffrey No.58544son o58544son PE No Murray7457PE No 77769311 71613 Ply:1 SEQN:19885/T52/JACK Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: J03A Wgt:9.8 lbs ... / ... 09/25/17 12 6 , 22'5"15 3X4(**)A p � p� 20'1 1" 4n83' '18 3'1"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl!CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA A 98 /23 /51 /- /66 /1.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA C 42 /3 /20 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.002 C - - B 73 /59 /41 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.003 C - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:22.03 ft Code/Misc Criteria Creep Factor:1.5 Soffit 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.203 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.128 Chords Tens.Comp. Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 A-B 33 -60 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Bot Chord Forces Per Ply(lbs) Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Chords Tens.Comp. Lumber A-C 0 0 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Bot chord 2x4 SP#3 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 3.00 BC 36 0.00 3.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 1-10-7. NOTES: r 1611H1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ TrueHouse PE Noel 60839 1owski Jeffrey 58544PE No 71457 PE No.77693 Arneson Murray Adam K Russell APEX 71613 Ply:1 SEQN:19879/T61/EJAC Jo&Brian Adcock Residence Qty: 2 FROM:KS DRW: J04 Wgt:15.4lbs / ... 09/25/17 T13- 22'11"15 12 6 I` CV rD 3X4('"`)B 4,7 M HDF20'11" A : D 4' 1'6"8 , 4 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 245 /57 /162 /- /71 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 52 /- /20 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - C 84 /40 /44 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.003 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:21.90 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.365 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.189 C Min Brg Width Req= - MWFRS Parallel Dist:h to 2h RepFactors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Chords Tens.Comp. Chords Tens. Comp. Lumber A-B 40 0 B-C 38 -75 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 4.00 BC 46 0.15 4.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 2-4-7. NOTES: 1 This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. (1111) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fit/\ UO��� Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX Truer], PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:19861/T17/JACK Jo&Brian Adcock Residence Qty: 10 FROM:KS DRW: J05 Wgt:18.2 lbs ... / ... 09/25/17 C 23'5"15 12 6 ra CV M 3X4(**)B 20'11" A : p 5' 1'6"8 1 5 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 274 /98 /176 /- /140 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 67 /- /26 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.004 D - - C 112 /94 /60 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.008 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:22.15 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.511 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.312 C Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 40 0 B-C 50 -93 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 5.00 BC 58 0.15 5.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 2-10-7. NOTES: 1.This drawing is not sufficient alone for installation_ Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (1:14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer /f*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE o.l 08391owski PE Na 58544son PE No MurrayDerek B7457Adam K Russe PE No 77769311 APEX 71613 Ply:1 SEAN:19888/T48/JACK Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: JO5A Wgt:15.4 lbs ... / ... 09/25/17 23'5"15 12 6 3X4(**)A T L / 0 (t) 20'11" )1:,& 5'1"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA A 164 /43 /85 /- /112 /1.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA C 71 /4 /33 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.008 C - - B 123 /101 /69 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.015 C - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:22.53 ft Code I Misc Criteria Creep Factor:1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.557 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.368 Chords Tens.Comp. Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 A-B 55 -97 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): - Maximum Bot Chord Forces Per Ply(lbs) Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Chords Tens.Comp. Lumber A-C 0 0 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Bot chord 2x4 SP#3 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 5.00 BC 60 0.00 5.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 2-10-7. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell True u�+�e PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:19909/T98/JACK Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: JO5B Wgt:15.4 lbs ... / ... 09/25/17 23'5"15 12 6 • 0 N 3X4(B1)A 5"3 (t) 20'11„ 1"84'1 0"8 4'f8 5' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSl Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA A 160 /41 /83 /- /110 /1.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA C 70 /3 /31 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.006 C - - B 121 /101 /68 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.013 C - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:22.57 ft Code/Misc Criteria Creep Factor:1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.553 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.339 Chords Tens.Comp. Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 A-B 54 -97 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Bot Chord Forces Per Ply(lbs) Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Chords Tens.Comp. Lumber Value Set:136(Effective 6/1/2013) A-C 0 0 Top chord 2x4 SP#3 Bot chord 2x4 SP#3 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 4.88 BC 59 0.00 4.88 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 2-10-7. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ reyerek APEX TrueHouse PE Noel Kozlowski PE No. 8 44son PE No. Murray14PE No.77769311 71613 Ply:1 SEQN:19858/T37/EJAC Jo&Brian Adcock Residence Qty: 16 FROM:KS DRW: J07 Wgt:23.8 lbs ... / ... 09/25/17 C 24'5"15 6 12 ih io 'v 3X4(**)B 1)20'11" A =' D 7' I--1'6"8 1 , -i Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 335 /70 /206 /- /143 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 96 /- /39 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.013 0 - - C 165 /99 /90 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.025 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:22.65 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.625 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.382 C Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 40 0 B-C 74 -120 Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 Bot chord 2x4 SP#2 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 7.00 BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 3-10-7. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE oel GO K3oozlowski Jeffrey No. 8544 on PE No.Derek B714u5y Adam K PE No 7 69311 APEX 71613 Ply:1 SEAN:19906/T53/EJAC Jo&Brian Adcock Residence Qty:4 FROM:KS DRW: J07B Wgt:21.0 lbs ... / ... 09/25/17 )�( �24'5"15 12 6 ih 3X4031)A 41. 111111 I. (1120'11" C 6'10"8 6.10..8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pt NA Ce:NA VERT(LL):NA A 224 /35 /118 /- /119 /1.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA C 98 /- /43 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.015 C - - B 170 /101 /95 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.030 C - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height 23.07 ft Code/Misc Criteria Creep Factor:1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.669 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.392 Chords Tens.Comp. Spacing:24.0" MWFRS Parallel Dist h/2 to h Rep Factors Used:Yes Max Web CSI: 0.000 A-B 76 -132 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Bot Chord Forces Per Ply(lbs) Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Chords Tens.Comp. Lumber A-C 0 0 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#2 Bot chord 2x4 SP#2 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.06 6.88 BC 75 0.06 6.88 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 3-10-7. NOTES: f- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ APEX TrueHouse PE Noel 60839 PE No.Kozlowski PE No 58544 on Murray1457PE No.77769311 71613 Ply:1 SEQN:19897/T15/MONO Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: JO7C Wgt:31.5 lbs ... / ... 09/25/17 1113X4(** B T 6 �12 M N. 3X4(A1)A IM o clii) AN 20'11" III4X5 *) 7' J i 7' • Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA A 477 /210 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA C 507 /248 /- /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.018 C - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C • HORZ(TL): 0.034 C - - A Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:23.03 ft Code/Misc Criteria Creep Factor:1.5 C Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.624 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.374 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.210 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. GCpi:0.18 Plate Type(s): A-B 70 -105 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Wind Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. Chords Tens.Comp. Top chord 2x4 SP#2 Right end vertical not exposed to wind pressure. A-C 23 -12 Bot chord 2x6 SP SS Dense Webs 2x4 SP#3 Additional Notes Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values The overall height of this truss excluding overhang is Webs Tens.Comp. approved 1/30/2013 by ALSC 3-10-7. B-C 104 -159 Special Loads ----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 56 plf at 0.00 to 56 plf at 7.00 BC-From 5 plf at 0.00 to 5 plf at 7.00 BC- 98 lb Conc.Load at 1.15 BC- 164 lb Conc.Load at 3.15 BC- 297 lb Conc.Load at 5.06 Plating Notes (**)2 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 7.00 BC 82 0.15 7.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 611) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.08391owski Jeffrey No.58544 n PE No.71457 PE No 77769311 71613 Ply:1 SEQN:19900/T101/EJAC Jo&Brian Adcock Residence Qty: 5 FROM:KS DRW: J08 Wgt:8.4 lbs ... / ... 09/25/17 C 6 1N 21'11"15 3X4(**)B o .r A 1 N Ada 2011 A ►i D Mr H 1'6"8 2' 2' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pt NA Ce:NA VERT(LL):NA B 202 /83 /148 /- /71 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 21 /7 /15 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - C 19 /22 /21 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL):-0.001 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:21.40 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.326 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.063 C Min Brg Width Req= - MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 40 0 B-C 9 -31 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 2.00 BC 22 0.15 2.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 1-4-7. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE Noel 60839 PE No. 854PE No Kozlowski 4 on Murray1457PE No.77769311 71613 Ply:1 SEQN:19938/T34/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: J10 Wgt:16.1 lbs ... / ... 09/25/17 1'10"8 3' 1'10"8 I 1'1"8 6 %4X64(**) III3X4g*) T 3X4(A1)A I M T I. M r- I 1 0 20'11" om um III3X4 III 3X4( *) 3' k 3' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl!CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.015 E 999 240 A 754 /257 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.029 E 999 180 D 430 /170 /- /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.008 B - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.014 B - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:21.75 ft Code/Misc Criteria Creep Factor:1.5 D Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.272 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.600 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.058 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 26 -36 B-C 12 -33 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Wind Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2 A-E 46 -23 E-D 33 -12 Bot chord 2x6 SP#2 Additional Notes Webs 2x4 SP#3 The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values 1-3-11. Webs Tens.Comp. Webs Tens. Comp. approved 1/30/2013 by ALSC B-E 69 -82 C-D 41 -87 Special Loads (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 56 plf at 0.00 to 56 plf at 1.87 TC-From 56 plf at 1.87 to 56 plf at 3.00 BC-From 5 plf at 0.00 to 5 plf at 3.00 TC- 33 lb Conc.Load at 1.88 BC- 926 lb Conc.Load at 1.06 BC- 43 lb Conc.Load at 1.88 Plating Notes (**)3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 3.00 BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: f- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi /\ GAPEX TrueHouse PE Noel 0 3o�zlowski PE No. 8544 Derek Br son PE No 71457y PE No.7769311 71613 Ply:1 SEQN:19927/T18/COMN ' Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: J11 Wgt:16.1 lbs ... / ... 09/25/17 I- 1'10"8 I 3' 1'10"8 1'1"8 6 %4X4(**) III3X4E*) '=_=1 T 3X4(A1)A � in � spri III IM_AI0 20'11" ►i E D* 1113X4 1113X4( ) 3' A 3' A Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.010 E 999 240 A 615 /213 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.019 E 999 180 D 364 /149 /- /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.005 B - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.009 B - - A Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:21.75 ft Code/Misc Criteria Creep Factor:1.5 D Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.170 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.210 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.037 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 25 -34 B-C 8 -21 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Wind Maximum Bot Chord Forces Per Ply(lbs) Value Set:138(Effective 6/1/2013) Wind loads and reactions based on MWFRS. Chords Tens.Comp. Chords Tens. Comp. Topchord2x4SP#2 A-E 35 -19 E-D 21 -8 Bot chord 2x6 SP SS Dense Additional Notes Webs 2x4 SP#3 The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values 1-3-11' Webs Tens.Comp. Webs Tens. Comp. approved 1/30/2013 by ALSC B-E 72 -85 C-D 33 -66 Special Loads (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 56 plf at 0.00 to 56 plf at 1.88 TC-From 56 plf at 1.88 to 56 plf at 3.00 BC-From 5 plf at 0.00 to 5 plf at 3.00 TC- 33 lb Conc.Load at 1.88 BC- 721 lb Conc.Load at 1.06 BC- 43 lb Conc.Load at 1.88 Plating Notes (")3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 3.00 BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61'1.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No 160839 G Kozlowski 0 391owski JFE No 5854gson FE No Murray7457APE No 7769311 71613 Ply:1 SEAN:19924/T60/MONO Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: J12 Wgt:18.2 lbs ... / ... 09/25/17 1113X4(" B 6 12 r` CV 3X4(A1)A -I- � �� rr � ( ICI) 20r11 PM DI 3X4(*) r 4' i Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA A 499 /165 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA C 485 /160 /- /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.007 C - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.014 C - - A Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:22.28 ft Code/Misc Criteria Creep Factor:1.5 C Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.282 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.352 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.054 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. GCpi:0.18 Plate Type(s): A-B 34 -46 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Wind Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. Chords Tens.Comp. Top chord 2x4 SP#2 Right end vertical not exposed to wind pressure. A-C 14 -5 Bot chord 2x6 SP SS Dense Webs 2x4 SP#3 Additional Notes Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values The overall height of this truss excluding overhang is Webs Tens.Comp. approved 1/30/2013 by ALSC 2-4-7. B-C 59 -105 Special Loads (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 56 plf at 0.00 to 56 plf at 4.00 BC-From 10 plf at 0.00 to 10 plf at 4.00 BC- 721 lb Conc.Load at 2.06 Plating Notes (••)2 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 4.00 BC 46 0.15 4.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers I Ties (J)Hanger Support Required,by others NOTES: \" 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo u se Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:20004/T9/JACK Jo&Brian Adcock Residence Qty: 6 FROM:KS DRW: J13 Wgt:5.6lbs ... / ... 09/25/17 12 4 C 3X4(**) B " MJr T ,\ 10'5"13 RPMFA cC �\ 10'1"2 _v_ A ....... ._ T NVD r 1.6..8 1' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 218 /108 /160 /- /28 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 1 /20 /20 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.000 D - - C -45 /45 /38 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL):-0.000 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.474 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.063 C Min Brg Width Req= - MWFRS Parallel Dist 0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 28 0 B-C 39 -19 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 1.00 BC 10 0.15 1.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 0-8-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fit/\ APEX TrueHouse PE No 0839 lowski Jeffrey PE No. 854gson pE No Murray7457PE No.77769311 71613 Ply:1 SEQN:20001/T8/JACK Jo&Brian Adcock Residence Qty:6 FROM:KS DRW: J14 Wgt:11.2 lbs ... / ... 09/25/17 12 C 4 d, 11'1"13 co 3X4(') B r co 4"3 A T 10'1 2 ►� D 3' 1'6"8 3' Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 218 /74 /143 /- /50 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 36 /0 /15 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - C 52 /30 /22 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.001 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor 1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.303 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.083 C Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 28 0 B-C 17 -30 Value Set:138(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#3 Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"136"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 3.00 BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 1-4-3. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse Michael Noel G0 Kozlowski Jeffrey No. 8544�n Derek BPE No. Murray7457Adam K PE No.77769311 APEX 71613 Ply:1 SEQN:19998/T6/JACK • Jo&Brian Adcock Residence Qty: 6 FROM:KS DRW: J15 Wgt:16.8 lbs ... / ... 09/25/17 C 4 12 11119"13 1 cli) M O co NI 3X4(**) B N 3 A � 10'1'2 ►� D 1'6rr8 �_ 5' 5' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 271 /78 /168 /- /73 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 65 /- /25 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.004 D - - C 108 /58 /52 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.008 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.429 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.299 C Min Brg Width Req= - MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 28 0 B-C 34 -53 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 5.00 BC 58 0.15 5.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 2-0-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 611 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ APEX TrueHouse PE No Michael 0 39PE No 58544PE No. Kozlowski Arneson Murray1457PE No.Adam Russell 71613 Ply:1 SEQN:19995/T11/EJAC Jo&Brian Adcock Residence Qty: 9 FROM:KS DRW: J16 Wgt:23.8 lbs .. / ... 09/25/17 C 12 A 12'5"13 4 M Co 00 N � 3X4(**)B 3 A 111111111111111111111.111111@ 10'1"2 7' 1'6"8 11 7' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc LJdefl L/# Loc R /U /Rw /Rh /RI_ /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 331 /93 /198 /- /97 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 94 /- /38 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.014 D - - C 160 /85 /79 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.026 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.591 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.368 C Min Brg Width Req= - MWFRS Parallel Dist:h/2 to h RepFactors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 28 0 B-C 51 -69 Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 Bot chord 2x4 SP#2 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 7.00 BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 2-8-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11r1.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Michael G ZrueHouse PE No.0 391owski Jeffrey ENo. 8544son PE No. Murray1457PE No.7769311 71613 Ply:1 SEQN:20019/T22/JACK Jo&Brian Adcock Residence Qty: 6 FROM:KS DRW: J17 Wgt:5.6 lbs ... / ... 09/25/17 12 4 C 3X4(**) B „ M ,\ 10'5"13 4"3 A , �\ 101 2 ► D \/ F3 H 1 r6"8 1' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Ldefi L# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 232 /129 /188 /- /30 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 2 /23 /22 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.000 D - - C -64 /64 /52 /- /- /1.5 Des Ld: 32.00 EXP:C - - HORZ(TL):-0.000 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.474 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.069 C Min Brg Width Req= - Spaong:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver 17.01.01.0630.10 Lumber A-B 26 0 B-C 57 -25 Value Set:136(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes ('*)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 1.00 BC 9 0.25 1.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Additional Notes The overall height of this truss excluding overhang is 0-8-3. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (41) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation, Florida Engineer Ji*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No 160839 G Kozlowski 039lowskiJeffrey No 58544son FEFE No Murray71457 E No 7 69311 71613 Ply:1 SEQN:20016/T21/JACK Jo&Brian Adcock Residence Qty: 6 FROM:KS DRW: J18 Wgt:11.2 lbs / ... 09/25/17 12 C 4 A T I 11'1"13 M 3X4(**) B co o A 1 10'1"2 ► D H 16n8 3' I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 226 /77 /148 /- /50 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 34 /1 /15 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - C 47 /28 /19 /- /- /1.5 Des Ld: 32.00 EXP:C --- HORZ(TL): 0.001 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.485 D Min Brg Width Req= - BCDL:3.0 sf TPI Std: 2007 Max BC CSI: 0.106 C Min Brg Width Req= - Load Duration:1.25 P Bearing B Fcperp=565psi. Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 - -- Lumber A-B 28 0 B-C 15 -42 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 3.00 BC 33 0.25 3.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Additional Notes The overall height of this truss excluding overhang is 1-4-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03.. should be used in conjunction with the architectural plans during installation. (iirrH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court.Suite 402,Jacksonville,FL 32224-904.821.5200 fi /\ TrueHouse PE NoMichael 0 3o�zlowski Jeffrey No 58544son Derek B PE No 71457y Adam K PE No.77769311 APEX 71613 Ply:1 SEQN:20013/T19/JACK Jo&Brian Adcock Residence Qty: 6 FROM:KS DRW: J19 Wgt:16.8 lbs ... / ... 09/25/17 12C 4 11'9"13 i O c0 N 3X4(**)B c�.l 43 A 1 _ ___EFDF__10'1"2 D F3', 1'6"8 5 H 5 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 277 /80 /172 /- /73 /5.5 BOLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 64 /- /25 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.003 D - - C 105 /57 /50 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.006 D - - Wind reactions based on MWFRS NCBCLL: W.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.403 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.286 C Min Brg Width Req= - MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0" C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 28 0 B-C 33 -57 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 5.00 BC 57 0.25 5.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Additional Notes The overall height of this truss excluding overhang is 2-0-3. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (j!f{t) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE No Michae160 83G 9 Jeffrey JrNo No.58544 PEPE No Murray7457Asse PE No dam K7 69311 APEX 71613 Ply:1 SKIN:20010/172/EJAC Jo&Brian Adcock Residence Qty:4 FROM:KS DRW: J20 Wgt:23.8 lbs ... / ... 09/25/17 C 12 12'5"13 4 L/ co Co co N 3X4(**)B V' q 1( 10'1"2 I3'. 1'6"8 7' 7' Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA CI:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 336 /94 /202 /- /97 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 93 /- /37 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.012 D - - C 158 /85 /77 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.022 D - - Wind reactions based on MWFRS NCBCLL:10.00 Mean Height:15.00 ft Code I Misc Criteria Creep Factor:1.5 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.573 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.357 C Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber A-B 28 0 B-C 50 -75 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes (**)1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 7.00 BC 75 0.25 7.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Additional Notes The overall height of this truss excluding overhang is 2-8-3. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. ( f{t) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer fif\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Tru eHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:20046/T41/MONO ' Jo&Brian Adcock Residence Qty: 10 FROM:KS DRW: J21 Wgt:22.4 lbs ... / ... 09/25/17 III 3X4(** C 4 12 , D � N N ib CV 3X4(**) B `" 43 qraill1111111M0 1 0'1"2 ►z� �� D 1113X4(**) 5'8" 1--- 1'6"8 1 5'8" i Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 291 /73 /178 /- /63 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 164 /33 /90 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.006 D - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.011 D - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 D Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.321 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.216 Spacing:24.0" MWFRS Parallel Dist h to 2h Rep Factors Used:Yes Max Web CSI: 0.116 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 B-C 22 -64 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) Chords Tens.Comp. Top chord 2x4 SP#2 B-D 18 -15 Bot chord 2x4 SP#2 Webs 2x4 SP#3 Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values Webs Tens.Comp. approved 1/30/2013 by ALSC C-D 143 -125 Plating Notes (")3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 5.67 BC 66 0.15 5.67 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 2-2-14. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402.Jacksonville,FL 32224-904.821.5200 fiV\ APEX TrueHouse PE Michael 39lowski rNo 5854gson PE PB No.71457y PE No.7 69311 71613 Ply:1 SEQN:20055/T23/EJAC Jo&Brian Adcock Residence Qty: 5 FROM:KS DRW: J22 Wgt:26.6 lbs ... / ... 09/25/17 I 6'2 12 -I 7' "I 6'2"12 9"4-I D 1113X4C �t 12'5"13 ,2 T4 Vdl M I H B 7"8 r m m V N N 1 th =3X4(..)B , 1 A - l 10'1"2 _ ��FE III 3X8(") 3" F k 5'11"12 1 I--1'6"8 I 6'2"12 19 4 I 6'2"12 7 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.009 F 999 240 B 285 /75 /174 /- /97 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.018 F 999 180 F 556 /215 /300 /- /- /5.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.004 F - - E -143 /143 /1 /- /- /1.5 Des Ld: 32.00 EXP:C HORZ(TL): 0.009 F - - D -228 /228 /115 /- /- /1.5 NCBCLL: W.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 Wind reactions based on MWFRS Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.307 B Min Brg Width Req= 1.5 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.219 F Min Brg Width Req= 1.5 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.137 E Min Brg Width Req= - D Min Brg Width Req= - C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber Bearings B&F Fcperp=565psi. GCpi:0.18 Plate Type(s): Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Maximum Top Chord Forces Per Ply(lbs) Lumber Chords Tens.Comp. Chords Tens. Comp. Value Set:13B(Effective 6/1/2013) A-B 28 0 C-D 57 -79 Top chord 2x4 SP#2 B-C 48 -85 Bot chord 2x4 SP#2 Webs 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Lumber value set"138"uses design values Chords Tens.Comp. Chords Tens. Comp. approved 1/30/2013 by ALSC B-F 5 -4 F-E 0 0 Plating Notes (**)2 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning Webs Tens.Comp. requirements. C-F 385 -419 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 7.00 BC 75 0.25 7.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Additional Notes Negative reaction(s)of-228#MAX.from a non-wind load case requires uplift connection.See Maximum Reactions. The overall height of this truss excluding overhang is 2-8-3. NOTES: IT 611H) 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE No.l 60839 PE PE No. 85effrey P 44son Derek B PE No Murray7457Adam PE No 7769311 APEX 71613 Ply:1 SEQN:20049/T96/MONO Jo&Brian Adcock Residence Qty: 5 FROM:KS DRW: J23 Wgt:15.4 lbs ... / ... 09/25/17 4 1- 1113X4(** C „gill i co 0 3X4(**) B , A / MA� 10'1"2 ► ►� D 1113X4(**) 16"8 3'6"8 3'6"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 231 /73 /148 /- /47 /5.5 BOLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 87 /18 /44 /- /- /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C .- HORZ(TL): 0.002 D - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code I Misc Criteria Creep Factor:1.5 D Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.179 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.074 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.046 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 B-C 17 -32 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) Chords Tens.Comp. Top chord 2x4 SP#2 B-D 5 -7 Bot chord 2x4 SP#2 Webs 2x4 SP#3 Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values Webs Tens.Comp. approved 1/30/2013 by ALSC C-D 91 -68 Plating Notes (")3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 3.54 BC 41 0.15 3.54 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 1-6-6. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 6111) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE G No 160 391owski PE No. 854gson PE No MurrayDerek B7457Adam K PE No 7 69311 APEX 71613 Ply:1 SEQN:20067/T100/MONO Jo&Brian Adcock Residence Qty: 4 FROM:KS DRW: J24 Wgt:22.4 lbs ... / ... 09/25/17 1113X4(** 12 1 12'0"7 4 3X4(** B , I Asrio 10'1"2 1113X8(**) 5'8"8 1'6"8 i 5'8"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.035 D 999 240 D 458 /199 /376 /832/695 /1.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.065 D 999 180 C - /- /- /832/675 /1.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.006 D - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.011 D - - NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 Maximum Top Chord Forces Per Ply(lbs) Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.600 Chords Tens.Comp. Chords Tens. Comp. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.714 A-B 29 0 B-C 896 -1068 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.251 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Bot Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber B-D 1095 -807 Value Set:13B(Effective 6/1/2013) Topchord 2x4 SP#2 Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Bot chord 2x4 SP#2 Webs 2x4 SP#3 C-D 423 -414 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Plating Notes (**)3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 5.71 BC 69 0.00 5.71 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The maximum horizontal reaction is 832# The overall height of this truss excluding overhang is 2-3-0. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. (11'1.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 "r*/\ TrueHouse MPE No 0 3o9zlowski Jeffrey No 5854gson FE No MurrayDerek B457Adam K PE No 7769311 APEX 71613 Ply:1 SEQN:19935/T63/COMN ' Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T01 Wgt:169.4 lbs ... / ... 09/25/17 . I 7' I 12'5"14 I 176"8 I 22'6"10 I 28'1" 7' 5'5"14 5'0"10 5'0"2 5'6"6 w6X8(") =3X4 m5X5(") =4X8 =6X6(")(1) B C D E F 12 7-___,, 0 io =4X5("))A =3X41.- - 2A J r Al 1_020'11" K J I H G 1113X4 =8X8(") =6X10 =6X8 111H0310(") 71"12 5'0"10 5'4"2 5'4"10 5'114 r 71"12 I 12,2"6 I 17'6"8 I 22'1x'2 I 28'1" 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.223 C 999 335 A 2083 /891 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.428 C 783 335 G 2000 /868 /- /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.050 B - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.096 B - - A Min Brg Width Req= 2.1 NCBCLL:10.00 Mean Height:23.03 ft Code/Misc Criteria Creep Factor:1.5 G Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.675 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.986 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.938 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 1787-4190 D-E 1926 -4596 Wind Duration:1.60 WAVE,HS VIEW Ver:17.01.01.0630.10 B-C 1967-4749 E-F 1207 -2806 Lumber Purlins C-D 1926-4596 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Top chord 2x4 SP M-31:T1 2x4 SP#1: to laterally brace chords as follows: Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x6 SP SS Dense Chord Spacing(in oc) Start(ft) End(ft) Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3:W8 2x4 SP#2: TC 24 0.00 28.08 A-K 3680-1552 I-H 2931 -1265 BC 71 0.15 28.08 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers K-J 3702-1556 H-G 7 -4 approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. J-I 4788-1994 Special Loads Wind Maximum Web Forces Per Ply(lbs) -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Wind loads and reactions based on MWFRS. Webs Tens.Comp. Webs Tens. Comp. TC-From 56 plf at 0.00 to 56 plf at 7.00 Right end vertical not exposed to windpressure. TC-From 28 plf at 7.00 to 28 plf at 20.44 p B-K 518 -98 I-E 2024 -804 TC-From 56 plf at 20.44 to 56 plf at 28.08 Additional Notes B-J 1260 -493 E-H 692 -1501 BC-From 10 plf at 0.00 to 10 plf at 7.01 J-C 329 -471 H-F 3372 -1450 BC-From 5 plf at 7.01 to 5 plf at 20.44 The overall height of this truss excluding overhang is C-I 82 -233 F-G 895 -2008 BC-From 10 plf at 20.44 to 10 plf at 28.08 3-10-7. D-I 312 -500 TC- 229 lb Conc.Load at 7.01 TC- 165 lb Conc.Load at 9.06,11.06,13.06,15.06 17.06,19.06 BC- 380 lb Conc.Load at 7.01 BC- 96 lb Conc.Load at 9.06,11.06,13.06,15.06 17.06,19.06 BC- 507 lb Conc.Load at 20.44 Plating Notes (I)-plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Tolerance,and/or zero Positioning Tolerance. (")7 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Hangers/Ties (J)Hanger Support Required,by others NOTES: It 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. �/� 6 ) 1H 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer J�- \ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Derek BAPEX Tru eHo use PE No Michael 60839 G Kozlowski 0 39lowski Jeffrey No.58544son o58544son FE No 71457y PE No 7 69311 71613 Ply:1 SEQN:19958/T57/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: 102 Wgt:189.0 lbs ... / ... 09/25/17 3' I 5' I 12'4"8 I 18'9" , 22'7"4 ) 26'1" , 30'1" 3' 2' 7'4"8 6'4"8 3'10"4 3'5"12 4' Em5X5(") • =3X4 " I in 612 _5X7(..)o D7(") ;ft6X6(") G T5 H=H0612( ) T is S '' .i to 11 =3X4 BB /w,✓ (8) �/ (a) = 1RE4X4(�)) N q/' •• ( f J 1 20'11.' P O N M L K 113X4 m4X4 =8X12(") =H1010(") =4X8 1113X4 ,T6"8 3'1"12 I I 7 '8" 6'8" , 3'10"12 I 3' I 4'1"12 16""8 3'1"12 11,6"1� 12'4"8 19'0"8 22'11"4 25'11"4 30'1" 4'8"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl!CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.334 F 999 357 B 1599 /745 /- I- I- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.643 F 556 357 1 1825 /812 I- /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.062 E - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.119 E - - B Min Brg Width Req= 1.6 NCBCLL:10.00 Mean Height:23.49 ft Code/Misc Criteria Creep Factor:1.5 I Min Brg Width Req= 1.8 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.894 Bearings B&I Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.987 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.966 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 40 -25 F-G 2289 -5202 Wind Duration:1.60 WAVE,HS VIEW Ver:17.01.01.0630.10 B-C 1205-2645 G-H 2048 -4819 Lumber Tray Scabs) C-D 1503-3303 H-I 1497 -3474 D-E 1039 -2242 I-J 40 -25 Value Set:13B(Effective 6/1/2013) (1)2x4x0-3-11 x SP#3 scab at each end.Attach E-F 1030-2230 Top chord 2x4 SP#2 15 2x6 SP SS Dense: scab to face of chord with:Nails @ 8"oc,plus Bot chord 2x6 SP SS Dense additional nail clusters at:BRG.:(0),heel:(0),1st Webs 2x4 SP#3 panel point:(0). Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values Purlins approved 1/30/2013 by ALSC B-P 2334 -1056 M-L 4885 -2090 In lieu of structural panels or rigid ceiling use purlins P-O 2365 -1069 L-K 3088 -1314 Bracing to laterally brace chords as follows: O-N 3492-1604 K-I 3080 -1318 Chord Spacing(in oc) Start(ft) End(ft) (a)Continuous lateral restraint equally spaced on TC 24 -1.48 31.56 N-M 5234-2316 member. BC 65 0.15 29.94 Apply purlins to any chords above or below fillers Maximum Web Forces Per Ply(lbs) Special Loads at 24"OC unless shown otherwise above. Webs Tens.Comp. Webs Tens. Comp. (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 56 plf at -1.54 to 56 plf at 3.00 Wind C-P 321 -134 F-M 188 -221 TC-From 56 plf at 3.00 to 56 plf at 5.00 Wind loads and reactions based on MWFRS. C-0 1242 -576 M-G 507 -225 TC-From 56 plf at 5.00 to 56 plf at 12.37 O-D 524 -979 G-L 281 -451 TC-From 56 plf at 12.37 to 56 plf at 18.75 Additional Notes D-N 742-1592 L-H 2026 -859 TC-From 56 plf at 18.75 to 56 plf at 26.08 The overall height of this truss excluding overhangis E-N 1509 -591 K-H 99 0 TC-From 56 plf at 26.08 to 56 plf at 31.62 BC-From 4 plf at -1.54 to 4 plf at 0.00 5-6-11. N-F 1505-3453 BC-From 10 plf at 0.00 to 10 plf at 30.08 BC-From 4 plf at 30.08 to 4 plf at 31.62 TC- 84 lb Conc.Load at 24.02 TC- 162 lb Conc.Load at 26.07 BC- 364 lb Conc.Load at 1.94 BC- 485 lb Conc.Load at 22.81 BC- 52 lb Conc.Load at 24.02 BC- 124 lb Conc.Load at 26.07 Plating Notes (")11 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'FINir 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer ,q*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Tru eHo u se MichaP Noel GO K3oozlowski PE No.58544son o58544son PE No. MurrayDerek B74Adam PE No.77769311 APEX 71613 Ply:1 SEQN:19930/T16/COMN ' Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW T03 Wgt:151.2lbs ... / ... 09/25/17 9' 156"11 21'8"1 28'1" I- 9' I 6'6"11 I 6,1'7 I 6.4.,15 I =6X8(") .5X5(") 1113X4 B C D -4X5E 12 a ■ C ■ s p ED .N.N.N.N.....6 0 0 3X4(**) A p T, I I III I 20'11" I -I G F 5X5(") =3X4 =6X8(") 1113X8(") 9'112 617 6'4"15 6'4"15 1 9'112 I 15'3"3 I 21'8'1 I 28'1'' 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.078 C 999 335 A 926 /267 /442 /- /156 /- BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.152 C 999 335 F 918 /413 /373 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.026 G - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.052 G - - A Min Brg Width Req= - NCBCLL:MOO Mean Height:23.53 ft Code/Misc Criteria Creep Factor:1.5 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.839 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.987 Maximum Top Chord Forces Per Ply(Ibs) Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.720 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 690-1554 C-D 523 -1049 GCpi:0.18 Plate Type(s): B-C 714-1415 D-E 523 -1049 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Lumber Hangers/Ties Maximum Bot Chord Forces Per Ply(Ibs) Value Set:13B(Effective 6/1/2013) Recommended hanger connections are based on Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#21-1 2x4 SP#1: manufacturer tested capacities and calculations. A-I 1300 -711 H-G 1417 -717 Bot chord 2x4 SP#2 Conditions may exist that require differentI-H 1304 -710 G-F 0 0 Webs 2x4 SP#3 connections than indicated.Refer to manufacturer publication for additional information. Lumber value set"13B"uses design values Maximum Web Forces Per PlyIbs approved 1/30/2013 by ALSC Bearing at location x0'= uses the following ( ) support conditions: Webs Tens.Comp. Webs Tens. Comp. PlatingNotes Bearing A (0',20'11")HTU26 B-I 254 0 D-G 279 -408 Supporting Member:(1)2x6 SP#2 (")6 plate(s)require special positioning.Refer to (20)0.148"x3"nails into supporting B-H 300 -117 G-E 1289 -642 scaled plate plot details for special positioning member, H-C 108 -124 E-F 483 -892 requirements. (11)0.148"x1.5"nails into supported C-G 245 -459 member. Purlins (J)Hanger Support Required,by others In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 28.08 BC 91 0.13 28.08 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 4-10-7. NOTES: "I' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111}{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer /f./\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Derek BAPEX Tru eHo use PE Noe160 39Kozlowski PE No. 854gson FE No.71457y PE No 7 69311 71613 Ply:1 SEQN:19961/T38/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T04 Wgt:194.6 lbs ... / ... 09/25/17 3' I 5' I 13' I 18'10"11 I 24'4"1 I 30'1" ' 3' 2' 8' 5'10"11 5'5'7 5'8"15 :5X7(") =5X5(•') Ill3X4 E F G = H T I -\\\- /6 12 _4X8(.*)w D8(•• ) - 7 - .4X5(A1)�� a-, A 0 ' .. OM _ 20'11" N M 0 L K J I 1 1113X4=4X4 1116X8(**) =-3X4 -6X80) 1113X8(") L16"8 1 3'x'12 8'3"8 57'3 56'.15 58'15 1 3'1"12 113' 1873 24'4"1 30'1" 4'8"8 • Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl LJ# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.131 D 999 359 B 1488 /711 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.255 D 999 359 I 1006 /496 /- /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.035 C - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.068 C - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:23.65 ft Code/Misc Criteria Creep Factor:1.5 I Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.776 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.974 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.709 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 40 -25 E-F 642 -1311 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 1117-2369 F-G 434 -880 Lumber Tray Scab(s) C-D 1379-2912 G-H 434 -880 Value Set:13B(Effective 6/1/2013) (1)2x4x0-3-11 x SP#3 scab at left end.Attach scab D-E 852-1693 Top chord 2x4 SP#2:T3 2x4 SP#1: to face of chord with:Nails @ 8"oc,plus additional Bot chord 2x4 SP#2:B1 2x6 SP SS Dense: nail dusters at:BRG.:(0),heel:(0),1st panel point: Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 (0). Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values Purlins B-N 2088 -977 L-K 1429 -703 approved 1/30/2013 by ALSC N-M 2122 -992 K-J 1302 -641 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: M-L 3062-1470 J-I 0 0 Bracing Chord Spacing(in oc) Start(ft) End(ft) (a)Continuous lateral restraint equally spaced on TC 24 -1.48 30.08 Maximum Web Forces Per Ply(lbs) member. BC 81 0.15 30.08 Webs Tens.Comp. Webs Tens. Comp. Apply purlins to any chords above or below fillers Special Loads at 24"OC unless shown otherwise above. C-N 348 -151 K-F 207 -20 -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) C-M 1047 -514 F-J 297 -605 TC-From 56 plf at -1.54 to 56 plf at 3.00 Wind M-D 470 -778 G-J 248 -357 TC-From 56 plf at 3.00 to 56 plf at 5.00 Wind loads and reactions based on MWFRS. D-L 781 -1662 J-H 1226 -604 TC-From 56 plf at 5.00 to 56 plf at 13.00 Right end vertical not exposed to wind pressure. E-L 411 -122 H-I 509 -982 TC-From 56 plf at 13.00 to 56 plf at 18.89 E-K 85 -167 TC-From 56 plf at 18.89 to 56 plf at 30.08 Additional Notes BC-From 4 plf at -1.54 to 4 plf at 0.00 BC-From 10 plf at 0.00 to 10 plf at 13.00 The overall height of this truss excluding overhang is BC-From 10 plf at 13.00 to 10 plf at 24.34 5-10-7. BC-From 10 plf at 24.34 to 10 plf at 30.08 BC- 430 lb Conc.Load at 1.94 Plating Notes (**)7 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Hangers/Ties (J)Hanger Support Required,by others , NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 6}{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX rue o u c �+ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell e PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:19986/T30/COMN ' Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T05 Wgt:156.8 lbs ... / ... 09/25/17 5' I 7' I 15' I 171" I 23'2"4 I 301" I5' 2' 8' 2'1 6'1"4 6'10"12 14X5(") 4X5("") E F G -b ..--54X4(**) 14X8("")12 C Dio 6 � (a) 4X4("")B :4X4("") Ate. - fttttttt8ttttttttIItlIItttttttItltttlII:z:_ : 20'11.. L K J I =3X4 =5X5(") =3X4 1113X4 F 1'6"8 i 5'3"8I 9'8"8 I 2,1" 63" 6.9" 5'3"8 15' 1T1" I 23.4• 30'1" 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.154 K 999 357 B 1080 /321 /515 /- /188 /3.5 BOLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.334 K 999 357 H 984 /290 /440 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.049 I - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.095 I - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:24.15 ft Code/Misc Criteria Creep Factor:1.5 H Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.942 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.997 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.518 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 40 0 E-F 698 -1128 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 853-1800 F-G 716 -1341 Lumber Hangers/Ties C-D 847-1627 G-H 813 -1768 Value Set:13B(Effective 6/1/2013) (J)Hanger Support Required,by others D-E 703-1365 Top chord 2x4 SP#2 Wind Maximum Bot Chord Forces Per Plylbs Bot chord 2x4 SP#2 (lbs) Webs 2x4 SP#3 Wind loads based on MWFRS with additional C&C Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values member design. B-L 1543 -709 J-I 1514 -646 approved 1/30/2013 by ALSC L-K 2066 -991 I-H 1515 -645 Additional Notes K-J 1128 -411 Bracing The overall height of this truss excluding overhang is (a)Continuous lateral restraint equally spaced on 6-10-7. Maximum Web Forces Per Ply(lbs) member. Webs Tens.Comp. Webs Tens. Comp. Plating Notes C-L 741 -369 F-J 337 -196 ('")7 plate(s)require special positioning.Refer to L-D 515 -792 J-G 270 -518 scaled plate plot details for special positioning D-K 615 -985 G-I 184 0 requirements. E-K 367 -109 Tray Scab(s) (1)2x4x0-3-11 x SP#3 scab at left end.Attach scab to face of chord with:Nails @ 8"oc,plus additional nail dusters at:BRG.:(0),heel:(0),1st panel point: (0). Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 30.08 BC 92 0.15 29.96 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (9111'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer lf*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PE No.l 60839 lowski Jeffrey 58544�n EPE No. Murray1457PE No.7 69311 71613 Ply:1 SEQN:19974/T65/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T06 Wgt:191.1 lbs ... / ... 09/25/17 4'1"12 I 6'5"8 8'5"8 I 16'0"8 I 17'9"8 I 24'2"12 I 30'1" I 4'1"12 2'3"12 2' 77" 19" 6'5"4 5'10"4 _ Fi 5X5(") - ? 0 1113X a 5X5(") =4X5("")D E 113x4 T4 n T 2rn n o 6 tl3X4 C to r �3X4(A1)B i-3X4(D1) 1.1 1 ^ Io �2a'11. ..4ANM NM L K J •8X8(") =8X8(") 113X4 =8X8("") I--4' 1 26'1" i 1.1'6"84'3"8 3'10"8 7'8"12 2'0"8 6'3"8 5'10"4 I 4'3"8 I 8'2" I 15'10"12 I 17'11"4I 24'2"12 I 30'1" I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.206 J 999 307 N 1311 /337 /686 /- /198 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.400 J 770 307 I 912 /234 /383 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.082 H - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):-0.165 H - - N Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:24.41 ft Code/Misc Criteria Creep Factor:1.5 I Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.573 Bearing N Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.317 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.775 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 0 E-F 471 -1074 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 513 -627 F-G 567 -1068 Lumber Hangers/lies C-D 487 -585 G-H 581 -1337 Value Set:13B(Effective 6/1/2013) (J)Hanger Support Required,by others D-E 387 -867 H-I 489 -1401 Top chord 2x4 SP#2:T4 2x6 SP SS Dense: Bot chord 2x6 SP SS Dense LoadingMaximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Truss passed check for 20 psf additional bottom Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values chord live load in areas with 42"-high x 24"-wide B-N 666 -416 L-K 1174 -333 approved 1/30/2013 by ALSC clearance. N-M 451 -93 K-J 1178 -335 Wind Bracing M-L 936 -296 J-I 1183 -340 (a)Continuous lateral restraint equally spaced on Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Plylbs member. member design. (lbs) Left cantilever is exposed to wind Webs Tens.Comp. Webs Tens. Comp. Plating Notes C-N 186 -203 L-F 767 -296 ("")6 plate(s)require special positioning.Refer to Additional Notes N-D 750-1222 L-G 442 -1048 scaled plate plot details for special positioning The overall height of this truss excluding overhang is D-M 908 -452 G-K 544 -179 requirements. 7-4-11. M-E 485 -783 J-H 156 -123 E-L 222 -136 Tray Scab(s) (1)2x4x0-3-11 x SP#3 scab at left end.Attach scab to face of chord with:Nails @ 8"oc,plus additional nail clusters at:BRG.:(0),heel:(0),1st panel point: (0). Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 29.96 BC 75 0.00 30.08 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 611'1.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 -- APEX Tru eHo use PE No Michael 0839Kozlowski PE No.58544Arneson o58544son PE No 71457y APE No.Russet 71613 Ply:1 SEQN:17422/T67/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T07 Wgt:196.7 lbs ... / .. 09/25/17 I 4'1"12 I 7'5"8 I 9'5"8 I 16'0"8 I 17'9"8 I 24'2"12 I 30'1" 4'1"12 3'3"12 2' 6'7" 1'9" 6'5"4 5'10"4 F 1114X5(") 511 Gg 3X4 3o5X5r) ==4X5(•")D E T 113 T4 :0000••••••</12iwlilli 83X4 Eov =3IX4(D1) 1 o Al 20'11" e47 N M L K J .8X8(*") =8X12(") 1113X4 113X4 F-4' 1 271" 1 11'6"8 I 4'3"8I 4'10"8 I 6'10"8 11'10"121 6'3"8 I 5 10 4 4'3"8 9'2" 16'0"8 17'11"4 24'2"12 30'1" Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.205 J 999 307 N 1312 /337 /687 /- /198 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.396 J 777 307 I 914 /234 /384 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.082 H - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):-0.163 H - - N Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:24.41 ft Code/Misc Criteria Creep Factor:1.5 I Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.434 Bearing N Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.317 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.784 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 0 E-F 482 -1053 Wind Duration:1.60 WAVE VIEW Ver:17.01.01A.0723.13 B-C 508 -627 F-G 579 -1073 Lumber Hangers/Ties C-D 491 -581 G-H 588 -1340 Value Set:13B(Effective 6/1/2013) Recommended hanger connections are based on D-E 432 -907 H-I 495 -1403 Top chord 2x4 SP#2:T4 2x6 SP SS Dense: manufacturer tested capacities and calculations. Bot chord 2x6 SP SS Dense Conditions may exist that require different Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 connections than indicated.Refer to manufacturer Chords Tens.Comp. Chords Tens. Comp. publication for additional information. Lumber value set"13B"uses design values Bearing at location x=29'10" uses the following B-N 665 -412 L-K 1176 -339 approved 1/30/2013 by ALSON-M 586 -150 K-J 1180 -340 support conditions: M-L 960 -312 J-I 1185 -346 Bearing ' " ' " HTU26 Plating Notes I (2910,2011 ) Supporting Member:(2)2x6 SP SS Dense (**)5 plate(s)require special positioning.Refer to (20)0.148"x3"nails into supporting Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning member, Webs Tens.Comp. Webs Tens. Comp. requirements. (11)0.148"x1.5"nails into supported member. C-N 200 -228 L-F 801 -345 Purlins N-D 804-1292 L-G 458 -1060 In lieu of structural panels or rigid ceiling use purlins Additional Notes D-M 791 -391 G-K 553 -176 to laterally brace chords as follows: The overall height of this truss excluding overhang is M-E 434 -699 J-H 159 -127 Chord Spacing(in oc) Start(ft) End(ft) 7-4-11. E-L 160 -95 TC 24 -1.48 29.96 BC 75 0.00 30.08 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. "V\ TH2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE Noel 0K3oozlowskiJeffrey No 58544sonAdam K PEPE No Murray1457PE No 7769311 71613 'Ply:1 SEAN: 17425/T68/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T08 Wgt:202.3 lbs ... / ... 09/25/17 I 41"12 4'11"12 9'5"6 11'5"816781r9"6I 24'2"12 301 4'1"12 10" 4'5"12 2' 4'7" 1'9" 6'5"4 5'10"4 G 84X5("") ! ..„H%3X4 4X4(•') 35X5("") E F a ss 113X4 T4 0 1,...::: T 6 04X5 D 1 0 113X4 C 1:, m 3X4A1)— I A p^� 20'11" ..4x.d0N M L K 8X8('") ..8x12("") It3X4 113X4 I--4' - 261" 1 1.6"8 1 478 5312 6'5"41'10"12 6'3"8 5'10"4 4'3"8 I 974 I 16'0"8 117'11"4I 24'2"12 I 301" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.204 K 999 307 O 1312 /321 /689 /- /198 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.395 K 779 307 J 914 /171 /386 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.083 I - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):-0.164 I - - 0 Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:24.41 ft Code/Misc Criteria Creep Factor:1.5 J Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.325 Bearing 0 Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.316 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.794 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 0 F-G 506 -1010 Wind Duration:1.60 WAVE VIEW Ver:17.01.01A.0723.13 B-C 511 -639 G-H 600 -1079 Lumber Wind C-D 479 -609 H-I 602 -1340 Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C D-E 408 -905 I-J 510 -1403 E-F 418 -762 Top chord 2x4 SP#2:T4 2x6 SP SS Dense: member design. Bot chord 2x6 SP SS Dense Left cantilever is exposed to wind Webs 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Lumber value set"13B"uses design values Chords Tens.Comp. Chords Tens. Comp. approved 1/30/2013 by ALSC B-O 677 -413 M-L 1176 -352 O-N 461 -293 L-K 1180 -353 Plating Notes N-M 953 -315 K-J 1185 -359 (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning Maximum Web Forces Per Ply(lbs) requirements. Webs Tens.Comp. Webs Tens. Comp. Purlins C-O 79 -173 F-M 155 -130 In lieu of structural panels or rigid ceiling use purlins O-D 722-1127 M-G 888 -436 to laterally brace chords as follows: D-N 878 -533 M-H 492 -1073 Chord Spacing(in oc) Start(ft) End(ft) E-N 194 -77 H-L 555 -174 TC 24 -1.48 29.96 N-F 332 -551 K-I 159 -127 BC 75 0.00 30.08 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Additional Notes The overall height of this truss excluding overhang is 7-4-11. NOTES: f' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61-1{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer I� Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.Michael 08391owski Jeffrey No.58544son o58544son FE No. Murray74PE No.77769311 71613 'Ply:1 SEQN:17430/T62/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T09 Wgt:202.3 lbs ... / ... 09/25/17 H 4'3"811'11' I 13' 11 I 18'1" , 24'2"12 I 30'1" 4'3"8 6'8"8 2' 4'1" 6'1"12 5'10"4 s4X5(") =5X5(") =4X8(••) Fw4X4 c' T D 'rr '1 ; 12 6 � I13X4 e b T5 to `o ,- 04X4 C o w =3X4(A1)B _ — .1m3X4(D1) e —4- 2Oir M L K J 84^" 4X4 =8X8(**) =8X8(") 193X4 I--4' j 261" 1 E.16"8 i 41"12 , 6'10"4I 1'10"4 I 4'10"11 I 6'5"13 I 5'10"4 4'1"12 11' 12'10"4 17'8"15 24'2"12 301" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TOLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.238 J 999 309 N 1304 /334 /693 /- /173 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.461 J 672 309 I 920 /170 /396 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.101 H - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):-0.201 H - - N Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:23.90 ft Code/Misc Criteria Creep Factor:1.5 I Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.591 Bearing N Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.350 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.667 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 0 E-F 577 -1017 Wind Duration:1.60 WAVE VIEW Ver:17.01.01A.0723.13 B-C 500 -615 F-G 612 -1149 Lumber Wind C-D 468-1013 G-H 604 -1313 D-E 512 -905 H-I 506 -1363 Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Top chord 2x4 SP#2:T5 2x6 SP SS Dense: member design. Bot chord 2x6 SP SS Dense Left cantilever is exposed to wind Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values B-N 650 -402 L-K 918 -275 approved 1/30/2013 by ALSC N-M 560 -375 K-J 1141 -349 Plating Notes M-L 829 -258 J-I 1147 -356 (**)5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. requirements. N-C 783-1207 L-F 101 -170 Purlins C-M 1084 -673 F-K 532 -215 In lieu of structural panels or rigid ceiling use purlins D-M 227 -219 K-G 159 -12 to laterally brace chords as follows: D-L 292 -166 J-H 181 -162 Chord Spacing(in oc) Start(ft) End(ft) L-E 210 -405 TC 24 -1.48 29.96 BC 75 0.00 30.08 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers I lies (J)Hanger Support Required,by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Additional Notes The overall height of this truss excluding overhang is 6-4-7. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111}{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer ifi*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse MichaPE oel GO 3oozlowski Jeffrey FE No. 854gson FE No 71457y APE No.Russell 693 71613 Ply:1 SEQN:17433/T49/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T10 Wgt:196.0 lbs ... / ... 09/25/17 71 4'1"12 4'9" 9' 11' 1 17'11"4 20'1" 24'2"12 301" 4'1"12 7"4 4'3" I 2' I I 5'11"4 I 2'1"12 I 4'1"12 I 5'10"4 I >a4X5(") 113X4 CH0510(") 05X5(") G=5X5 T4 H I I .1612N3 1113X4 113X4 D o b_ 13X4 C T5 19 lN �� K=4iiiX4(") s3X4(A7)B W J2011" 1 �' A =4X110 N M L =8X8(") max8r) 1113X4 I--4' 1 261" 1 1'6"8 4'5"4 6'5" 6'10"8 6'6" 5'10"4 I— -h 4'S"4 + 10'10"4 + 17'8"12 + 24'2"12 + 30'1" Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.140 L 999 309 0 1304 /358 /692 /- /148 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.287 L 999 309 K 920 /172 /395 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.049 J - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):-0.114 J - - 0 Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:23.40 ft Code/Misc Criteria Creep Factor:1.5 K Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.347 Bearing 0 Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.232 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI:0.954 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 0 F-G 553 -1030 I Wind Duration:1.60 WAVE,HS VIEW Ver:17.01.01A.0723.13 B-C 429 -576 G-H 641 -1283 Lumber Wind C-D 396 -559 H-I 644 -1283 Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C D-E 420 -497 I-J 638 -1390 E-F 503 -953 J-K 590 -1521 Top chord 2x4 SP#2:T4,15 2x6 SP SS Dense: member design. Bot chord 2x6 SP SS Dense Left cantilever is exposed to wind Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC B-O 1171 -702 M-L 1282 -424 O-N 737 -233 L-K 1280 -426 Plating Notes N-M 991 -324 (")6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning Maximum Web Forces Per Ply(lbs) requirements. Webs Tens.Comp. Webs Tens. Comp. Purlins C-O 65 -141 N-G 163 -191 In lieu of structural panels or rigid ceiling use purlins O-D 198 -277 G-M 532 -226 to laterally brace chords as follows: O-E 796-1253 M-H 130 -35 Chord Spacing(in oc) Start(ft) End(ft) E-N 595 -274 L-J 119 -17 TC 24 -1.48 29.96 N-F 213 -389 BC 75 0.00 30.08 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Additional Notes The overall height of this truss excluding overhang is 5-4-7. NOTES: 't- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. T. 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer fi'/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 �+ p �+ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX 1 U G U J PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:19980/T56/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T11 Wgt:156.8 lbs ... / ... 09/25/17 4'1"127' 9' 12'48 149" 221" 30'1" 4.1••12 I 2'10••4 I 2' I 3'4"8 I 2'4"8 I 7'4" I 8' F 114X5(") =5X7(") �o4X5(') ��SXSP') H IIIIII �4X5(..1,���.. 12 T 6 f, 1113X40 E.. a 1 "F .3X4(**)El 1=3X4(") A !o rI 20'11' _3AM L K J 4X8 =5X7(") 1113X4 I-4' 1 26'1"-- - i 115"8 I 4'3"8 4'6••12I 8'0"8 I 7'0"8 I 8'1"12 4'3"8 8'10"4 14'10"12 21'11"4 30'1" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria A Maximum Reactions(lbs) TOLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.072 G 999 307 M 1253 /354 /685 /- /155 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.151 G 999 307 I 836 /245 /392 /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.023 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.051 F - - M Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:23.49 ft Code/Misc Criteria Creep Factor:1.5 I Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.613 Bearings M&I Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.583 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.507 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 40 0 E-F 605 -963 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 519 -621 F-G 883 -1491 Lumber C-D 505 -572 G-H 726 -1261 Value Set:138(Effective 6/1/2013) D-E 478 -804 H-I 686 -1408 Top chord 2x4 SP#2 Bot chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values B-M 657 -419 K-J 1185 -498 approved 1/30/2013 by ALSO M-L 474 -144 J-I 1182 -499 L-K 840 -318 Plating Notes (")8 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning Webs Tens.Comp. Webs Tens. Comp. requirements. C-M 191 -222 F-K 1049 -570 Purlins M-D 844 -1218 G-K 578 -930 In lieu of structural panels or rigid ceiling use purlins D-L 745 -428 K-H 87 -63 to laterally brace chords as follows: L-E 391 -566 J-H 244 0 Chord Spacing(in oc) Start(ft) End(ft) L-F 200 -167 TC 24 -1.48 30.08 BC 75 0.00 29.94 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Additional Notes The overall height of this truss excluding overhang is 5-6-11. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.Michael 60Kozlowski PE No.58544son o5854gson PE No.71457y PE No 7769311 71613 Ply:1 SEQN:19955/T58/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T12 Wgt:154.0 lbs ... / ... 09/25/17 5' 7' 174"8 169" 24'1" 30'1" I 5' I 2' I 5'4"8 I 4'4"8 I 7'4" I 6' E 114X5(•') =6X6(") I 114X5(");;5X5('•) �Fe5X5(") G ,2 o c T o T 6p - uP. - to I i71c eq � >f4X4(«)B a H=4X4(") 1 1 ?f A•0000". 1 I2011" M L K J .3X4 .5X7(••) =5X5('•) 1113X4 1'6"el 53"8 I 7'1" I 4'8" I 6'10"12 I 61 12 11 6"� 5'3"8 12'4"8 17'0"8 23'11"4 30'1" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pfin PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udell U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.192 F 999 357 B 1076 /322 /505 /- /171 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.372 F 959 357 H 1076 /325 /506 /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.052 J - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):0.102 J - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:23.49 ft Code I Misc Criteria Creep Factor:1.5 H Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.950 Bearings B&H Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.976 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.694 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.01 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): ,A-B 40 0 E-F 882 -1573 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 912-1776 F-G 1269 -2339 Lumber C-D 895-1597 G-H 903 -1788 Value Set:13B(Effective 6/1/2013) D-E 865-1578 H-I 40 0 Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values B-M 1525 -682 K-J 1541 -697 approved 1/30/2013 by ALSC M-L 1990 -937 J-H 1539 -699 L-K 2367 -1114 Plating Notes (**)9 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning Webs Tens.Comp. Webs Tens. Comp. requirements. C-M 636 -320 L-F 700 -1235 Purlins M-D 453 -711 F-K 230 -298 In lieu of structural panels or rigid ceiling use purlins D-L 454 -704 K-G 870 -487 to laterally brace chords as follows: E-L 1083 -564 J-G 199 0 Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 31.56 BC 90 0.15 29.94 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 5-6-11. NOTES: f' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11H 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PE Noel 08391owski PE No.58544 n PE No.71457y PE No.7769311 71613 Ply:1 SEQN:19918/T59/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T13 Wgt:92.4 lbs ... / ... 09/25/17 6'3'13I 9' I 11'9" 14'5"3 I 20'9" 6'3"13 2'8"3 2'9" 2'8"3 6'3"13 w4X4(") rk4X4(") C D r. ,2 6 ....3X4 B• E M3X4 • 0 v / 3X4(..) A F w3X4(") J_ „.� IN NO ..r 20'11,. H G =3X4 =5X5(") 9' 2'9" 9' A 9' I 11,9„ I- 20,9" • Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defi/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.048 G 999 246 A 721 /202 /309 /- /113 /- BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.120 G 999 246 F 721 /202 /309 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.019 G - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):0.045 C - - A Min Brg Width Req= - NCBCLL:10.00 Mean Height:23.53 ft Code/Misc Criteria Creep Factor:1.5 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.389 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.789 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.120 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 554-1204 D-E 513 -991 GCpi:0.18 Plate Type(s): B-C 514 -991 E-F 554 -1204 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 C-D 468 -836 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 4-10-7. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 A-H 1017 -414 G-F 1017 -415 Webs 2x4 SP#3 H-G 836 -263 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. (**)5 plate(s)require special positioning.Refer to B-H 232 -320 D-G 314 -145 scaled plate plot details for special positioning C-H 314 -145 G-E 232 -320 requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 20.75 BC 120 0.13 20.63 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: Ill" 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. fiV\ TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PE Noel GO K3oozlowski Jeffrey NNo. 8544son FE No Murray71457PE No.7 69311 71613 Ply:1 SEQN:19921/T55/HIPS Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T14 Wgt:84.0 lbs ... / ... 09/25/17 7' 137 20'9" 7' 6'9" 7' 5X7(") B T2 12 6 o_ =3X4RA Dm3X8(**) ay �� 20'11" F E 1113X4 =5X7(") - 7'1"12 6'3"12 778 ` 7'1"12 13'5"8 20,9" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.120 F 999 245 A 1570 /683 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.230 F 999 245 D 1570 /683 /- /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.051 E - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.098 E - - A Min Brg Width Req= 1.9 NCBCLL:10.00 Mean Height:23.03 ft Code/Misc Criteria Creep Factor:1.5 D Min Brg Width Req= 1.9 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.856 Bearings A&D Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.994 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.215 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 1319-3054 C-D 1319 -3047 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 1140-2703 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2:T2 2x4 SP M-31: Additional Notes Bot chord 2x4 SP#1 A-F 2663-1135 E-D 2657 -1134 Webs 2x4 SP#3 The overall height of this truss excluding overhang is F-E 2686-1137 Lumber value set"13B"uses design values 3-10-7. approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Special Loads Webs Tens.Comp. Webs Tens. Comp. -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) B-F 560 -69 E-C 565 -70 TC-From 56 plf at 0.00 to 56 plf at 7.00 B-E 20 -3 TC-From 28 plf at 7.00 to 28 plf at 13.75 TC-From 56 plf at 13.75 to 56 plf at 20.75 BC-From 10 plf at 0.00 to 10 plf at 7.01 BC-From 5 plf at 7.01 to 5 plf at 13.74 BC-From 10 plf at 13.74 to 10 plf at 20.75 TC- 229 lb Conc.Load at 7.01,13.74 TC- 165 lb Conc.Load at 9.06,10.37,11.69 BC- 380 lb Conc.Load at 7.01,13.74 BC- 96 lb Conc.Load at 9.06,10.37,11.69 Plating Notes (")6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 20.75 BC 68 0.15 20.60 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1 This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,*/\ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX True0 u Ce PE No.60839 PE No 58544 PE No 71457 PE No.77693 71613 Ply:2 SEQN:17413/T4/COMN Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T16 Wgt:290.5 lbs ... / ... 09/25/17 T7" 97" 13'6"8 187 25,1" I7,7„ I 2' I 3'11„8 I 5'2,8 I 6,4" I -- E,5X7(") �• 110X12(-) C6X6" D � Ttii ;0,,,,,,,,•••• 1► N4X8 m 0 T4v W4aG 3X4 - _ -,0X,2(5X=3X8(") �� `�=5X5(") A/�� BL, ?��, 20'11" :< K J I ... 85X7 =H1010(")(I) 113X8 1'6"8 i 7'10"8 5'8" 5'4"4 4'6"15 1'7 5 I A 7'10"8 I 13'6"8 I- 18'10"12 I 23'5"11 I 25'1" 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl!CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph N:NA Ce:NA VERT(LL): 0.229 J 999 295 B 4971 /2044 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.433 J 682 295 H 6826 /2208 /- /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.056 C - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.106 C - - B Min Brg Width Req= 2.6 NCBCLL:0.00 Mean Height:23.78 ft Code/Misc Criteria Creep Factor:1.5 H Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.912 Bearings B&H Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.991 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:No Max Web CSI: 0.845 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)110(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 20 -13 E-F 1677 -4386 Wind Duration:1.60 WAVE,HS VIEW Ver:17.01.01A.0723.13 B-C 2095-5170 F-G 2059 -6050 Lumber Special Loads C-D 1908-4745 G-H 2081 -6077 Value Set:13B(Effective 6/1/2013) -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) D-E 1656-4352 Top chord 2x4 SP#2 Ti: 2x4 SP#1: TC-From 56 plf at -1.54 to 56 plf at 7.58 T4 2x4 SP M-30: TC-From 28 plf at 7.58 to 28 plf at 9.58 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x6 SP SS Dense TC-From 28 plf at 9.58 to 28 plf at 13.54 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3:W4 2x4 SP#2: TC-From 56 plf at 13.54 to 56 plf at 25.08 B-K 4579-1844 J-I 5356 -1822 :Rt Slider 2x4 SP#3:BLOCK LENGTH= 2.000' BC-From 4 plf at -1.54 to 4 plf at 0.00 Lumber value set"13B"uses design values BC-From 10 plf at 0.00 to 10 plf at 7.06 K-J 5088-2007 I-H 5401 -1830 9 BC-From 5 plf at 7.06 to 5 plf at 25.08 approved 1/30/2013 by ALSC BC- 831 lb Conc.Load at 7.06 Maximum Web Forces Per Ply(lbs) BC-2000 lb Conc.Load at 9.13 Webs Tens.Comp. Webs Tens. Comp. BC- 918 lb Conc.Load at 11.06 Nail Schedule:0.131"x3",min.nails BC-1006 lb Conc.Load at 13.06 C-K 2150 -832 E-J 3744 -1384 Top Chord:1 Row @12.00"o.c. BC- 984 lb Conc.Load at 15.06 K-D 239 -834 J-F 396 -1693 Bot Chord:1 Row @ 3.75"o.c. BC- 912 lb Conc.Load at 16.52 D-J 728-1645 F-I 1484 -286 Webs :1 Row @ 4"o.c. BC- 914 lb Conc.Load at 17.52,19.52 Use equal spacing between rows and stagger nails BC- 920 lb Conc.Load at 21.52,23.52 in each row to avoid splitting. Wind Plating Notes Wind loads and reactions based on MWFRS. (I)-plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Bearing Block(s) Tolerance,and/or zero Positioning Tolerance. Brg blocks:0.131"x3",min.nails (")8 plate(s)require special positioning.Refer to brg x-loc #blocks length/blk #nails/blk wall plate scaled plate plot details for special positioning 2 24.792' 1 12" 4 SP Standard requirements. Brg block to be same size and species as chord. Refer to drawing CNNAILSP1014 for more information. Purlins In lieu of structural panels or rigid ceiling use purlins Additional Notes to laterally brace chords as follows: The overall height of this truss excluding overhang is Chord Spacing(in oc) Start(ft) End(ft) 6-1-11. TC 24 -1.48 25.08 BC 106 0.15 24.79 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (141}{ 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer if -'\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Tru eHo use PE Michael 391owski Jeffrey P PE No. 854gson pE No.71457y Adam K PE No.7 69311 APEX 71613 Ply:1 SEQN:19947/T33/SPEC Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T17 Wgt:154.0 lbs ... / ... 09/25/17 3' "I 4'9"12 9'1"8 11'1"8 1'10"8 14'1" 19'2"4 25'1" 4'9"12 4'3"12 I 2' I 11'1" 51"4 5'10"12 I 4X4(••) =4X4 F G =4X8(.,),4 H ti -1- T t,/ 12 H k3X4 ! 6 b m 4t3X4 C co ro q iD I iD =3X4('•)81=3X4(") <�r A WML=5X7(••) =3XTT3> 1'6"8 9'1"8 1'10"4 5'4"12 59" 1'6'8 I' 1 9'1"8 I10'11"12I I 19'4" I 251" 1 711"8 I 13'11"4 I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.076 E 999 297 B 912 /272 /447 /- /179 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.147 E 999 297 I 912 /272 /448 /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.029 K - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):0.055 K - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:23.65 ft Code/Misc Criteria Creep Factor:1.5 I Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.316 Bearings B&I Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.973 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.274 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 40 0 F-G 576 -898 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 703-1437 G-H 579 -1066 Lumber C-D 605-1186 H-I 662 -1426 D-E 613-1048 I-J 40 0 Value Set:13B(Effective 6/1/2013) E-F 723-1206 Top chord 2x4 SP#2 Bot chord 2x4 SP#2 Webs 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Lumber value set"136"uses design values Chords Tens.Comp. Chords Tens. Comp. approved 1/30/2013 by ALSC B-N 1233 -522 L-K 1213 -492 N-M 1011 -342 K-I 1214 -491 Plating Notes M-L 895 -296 (••)6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning Maximum Web Forces Per Ply(lbs) requirements. Webs Tens.Comp. Webs Tens. Comp. Purlins C-N 205 -263 F-L 139 -111 In lieu of structural panels or rigid ceiling use purlins D-N 314 -37 L-G 248 -112 to laterally brace chords as follows: D-M 147 -114 L-H 222 -381 Chord Spacing(in oc) Start(ft) End(ft) M-E 366 -580 H-K 161 0 TC 24 -1.48 26.56 M-F 501 -342 BC 120 0.15 24.94 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 5-10-7. NOTES: f' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11.11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fit/\ �+ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX rue U J e PE No 60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:19944/T46/HIPS Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T18 Wgt:106.4 lbs ... / 09/25/17 9' 151" 251" I 9' I- 7,1„ I- 9, I :=6X8") 6X66(") fro 12 6 n 0 m c io I =3X4(")B E_3X4(") v> A ri{ . F 20'11" H G =5X5(") =3X4 1'6'8 9'1"12 6'7"12 9'3"8 1'6"8 I A 9'1" 12 I 15'9"8 I- 251" 1 -I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl LH# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.046 H 999 297 B 912 /276 /451 /- /154 /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.089 H 999 297 E 912 /276 /451 /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.024 G - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.046 G - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:23.15 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.995 Bearings B&E Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.985 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.270 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 40 0 D-E 599 -1302 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 599-1303 E-F 40 0 Lumber C-D 624-1078 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 B-H 1073 -366 G-E 1072 -392 Lumber value set"13B"uses design values H-G 1076 -365 approved 1/30/2013 by ALSC Plating Notes Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning C-H 239 0 G-D 242 -19 requirements. C-G 219 -213 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.48 26.56 BC 116 0.15 24.94 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 4-10-7. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. fiV\ TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use PE No 160839 G Kozlowski 039lowski Jeffrey No.58544son o5854gson PE No.71457y PE No.7 69311 71613 Ply:1 SEON:17416/T92/HIPS Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T19 Wgt:126.0 lbs ... / ... 09/25/17 7' 12'6"8 18'1" 251" I7' I 56"8 I 5'6"8 I 7' I =4X10(") III 3X4 =4X10(") D E T2 F 12 6 p 0 ra t3X4C k3X4 FFo 6X8(")B G - J H=6X8(") v 3X4(") ` 3X4(") A oi' '1.„.. I 020'11' L K J r 13X4 m H0510(") 1113X4 1'6"8 7'1"12 5412 54"12 7'1"12 1'6"8 I A 71"12 I- 12,6"8 I- 17'11"4 I 251" 1 Loading Criteria(psf) 'Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udell U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.204 E 999 294 M 2014 /878 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.390 E 753 294 H 2004 /870 /- /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.064 J - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.122 J - - M Min Brg Width Req= 2.4 NCBCLL:10.00 Mean Height:22.65 ft Code/Misc Criteria Creep Factor:1.5 H Min Brg Width Req= 2.4 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.812 Bearings M&H Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.957 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.379 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 40 -25 E-F 1660 -4041 Wind Duration:1.60 WAVE,HS VIEW Ver:17.01.01A.0723.13 B-C 1575 -3699 F-G 1522 -3622 Lumber Purlins C-D 1537 -3644 G-H 1559 -3677 •Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins D-E 1660-4041 H-I 40 25 Top chord 2x4 SP#2:T2 2x4 SP#1: to laterally brace chords as follows: Bot chord 2x4 SP#1 Chord Spacing(in oc) Start(ft) End(ft) Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 TC 24 -1.48 26.56 Chords Tens.Comp. Chords Tens. Comp. :Lt Slider 2x4 SP#3:BLOCK LENGTH= 2.000' BC 61 0.29 24.79 :Rt Slider 2x4 SP#3:BLOCK LENGTH= 2.000' Apply purlins to any chords above or below fillers B-L 3205-1342 K-J 3205 -1331 at 24"OC unless shown otherwise above. L-K 3225-1346 J-H 3185 -1328 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Wind Maximum Web Forces Per Ply(lbs) Special Loads Wind loads and reactions based on MWFRS. Webs Tens.Comp. Webs Tens. Comp. -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Additional Notes D-L 500 -89 K-F 994 -390 TC-From 56 plf at -1.54 to 56 plf at 7.00 The overall height of this truss excluding overhang is D-K 970 -373 J-F 492 -79 TC-From 28 plf at 7.00 to 28 plf at 18.08 3-10-7. E-K 451 -733 TC-From 56 plf at 18.08 to 56 plf at 26.63 BC-From 4 plf at -1.54 to 4 plf at 0.00 BC-From 10 plf at 0.00 to 10 plf at 7.01 BC-From 5 plf at 7.01 to 5 plf at 18.07 BC-From 10 plf at 18.07 to 10 plf at 25.08 BC-From 4 plf at 25.08 to 4 plf at 26.63 TC- 238 lb Conc.Load at 7.01 TC- 170 lb Conc.Load at 9.06,11.06,12.54 TC- 165 lb Conc.Load at 14.02,16.02 TC- 229 lb Conc.Load at 18.07 BC- 387 lb Conc.Load at 7.01 BC- 98 lb Conc.Load at 9.06,11.06,12.54 BC- 96 lb Conc.Load at 14.02,16.02 BC- 380 lb Conc.Load at 18.07 Plating Notes (")7 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TrH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,*/\ Tru eHo use PE NoMichael G0 3o�zlowski pE No.58544 n Derek B PE No 71457y Adam K PE No.77769311 APEX • 71613 Ply:1 SEQN:19915/T47/COMN * Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T20 Wgt:46.2 lbs ... / ... 09/25/17 I' 2' 6'5" 12'5 12 6 =4x4(**) =4X88**) v =4X4(**)A D=4X4(**) 1 _ _ 20'11" 3X4 III 3X4 2'3"8 5'11"12 2'1"12 r 2'3"8 I 8'3"4 I 10'5" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CS1 Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.038 F 999 240 A 822 /263 /- /- /- /3.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.072 F 999 180 D 995 /280 /- /- /- /3.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.015 E - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.029 E - - A Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:21.78 ft Code/Misc Criteria Creep Factor:1.5 D Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.587 Bearings A&D Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.978 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.265 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 564-1767 C-D 574 -1940 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 530-1713 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#1 Additional Notes A-F 1548 -507 E-D 1707 -518 Webs 2x4 SP#3 The overall height of this truss excluding overhang is F-E 1801 -530 Lumber value set"13B"uses design values 1-4-7. approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Special Loads Webs Tens.Comp. Webs Tens. Comp. -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) B-F 627 -87 E-C 695 -86 TC-From 56 plf at 0.00 to 56 plf at 2.00 F-C 10 -90 TC-From 28 plf at 2.00 to 28 plf at 8.42 TC-From 56 plf at 8.42 to 56 plf at 10.42 BC-From 5 plf at 0.00 to 5 plf at 10.42 TC- 46 lb Conc.Load at 2.01,8.41 TC- 19 lb Conc.Load at 4.06,5.21,6.35 BC- 209 lb Conc.Load at 1.98 BC- 224 lb Conc.Load at 3.90,5.90,7.90,9.38 BC- 21 lb Conc.Load at 4.06,5.21,6.35 BC- 48 lb Conc.Load at 8.41 Plating Notes (**)4 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 10.42 BC 99 0.15 10.27 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: Ir- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (.11'}{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ii*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Jeffrey P APEX TrueHouse PE No.Michael 60839 G Kozlowski 0391owski PB No.58544 Ameson PE No.71457y APE No.Russell 71613 Ply:1 SEQN:19894/T79/HIPS Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T21 Wgt:49.0lbs ... / .. 09//25/17 5' I 7'7" _I 5' 2'7" 12 6 V -1- 1114x4(-•) _ A 1113X4 R ;5X5(")B tOrN. o_ i•-) n v i o_ N _ li�il�l� 2011" F E 1114X5(R)D 1113X4(") =3X4 4'8"8 2'10"8 1 4'8"8 I 77„ 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.005 E 999 240 F 297 /148 /- /- /- /- BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.009 E 999 180 D 831 /386 /- /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.003 C - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):-0.007 C - - F Min Brg Width Req= - NCBCLL:10.00 Mean Height:24.28 ft Code/Misc Criteria Creep Factor:1.5 D Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.338 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.542 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.127 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 142 -302 B-C 77 -83 GCpi:0.18 Plate Type(s): Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Maximum Bot Chord Forces Per Ply(lbs) Lumber Wind Chords Tens.Comp. Chords Tens. Comp. Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. F-E 8 -5 E-D 304 -150 Top chord 2x4 SP#2 End verticals not exposed to wind pressure. Bot chord 2x4 SP#2 Maximum Web Forces Per Ply(lbs) Webs 2x4 SP#3 Additional Notes Webs Tens.Comp. Webs Tens. Comp. Lumber value set"13B"uses design values The overall height of this truss excluding overhang is approved 1/30/2013 by ALSC 3-10-7. A-F 162 -284 B-D 194 -399 A-E 335 -156 C-D 152 -230 Special Loads E-B 75 -20 ---(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 56 plf at 0.00 to 56 plf at 5.00 TC-From 56 plf at 5.00 to 56 plf at 7.58 BC-From 10 plf at 0.00 to 10 plf at 7.58 TC- 231 lb Conc.Load at 7.01 BC- 399 lb Conc.Load at 7.01 Plating Notes (")3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 7.33 BC 91 0.00 7.58 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 6111) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ Tru eHo u se Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEAN:20031/T32/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T22 Wgt:61.6 lbs ... / ... 09/25/17 7' 13'8" 7' I 6'8" 6X8(**) 1114X5(**) C T2 D 12 T 4 (a) co E .99 N 3X4(**)B - ±12 q i -J 1 O 10'1"2 T. F E 1113X4 1115X7(**) H 1'6"8 1 T1"12 I 6'6"4 7'1"12 13'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.076 F 999 240 B 927 /306 /- /- /- /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.144 F 999 180 E 1187 /372 /- /- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.024 E - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):0.045 E - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.830 Bearings B&E Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.968 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.517 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 -13 C-D 20 -59 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 578-1909 Lumber Purlins Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Maximum Bot Chord Forces Per Ply(lbs) to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2:T2 2x4 SP M-30: Chord S acin m oc) n Bot chord 2x4 SP#2 p g( Edft( ) B-F 1751 -519 F-E 1786 -521 Webs 2x4 SP#3 TC 24 1.50 13.67 BC 92 0.15 13.67 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Webs Tens.Comp. Webs Tens. Comp. Bracing Wind C-F 578 -31 D-E 208 -398 (a)Continuous lateral restraint equally spaced on Wind loads and reactions based on MWFRS. C-E 532-1835 member. Right end vertical not exposed to wind pressure. Special Loads Additional Notes -----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) The overall height of this truss excluding overhang is TC-From 55 plf at -1.54 to 55 plf at 7.00 2-8-3. TC-From 27 plf at 7.00 to 27 plf at 13.67 BC-From 4 plf at -1.54 to 4 plf at 0.00 BC-From 10 plf at 0.00 to 10 plf at 7.01 BC-From 5 plf at 7.01 to 5 plf at 13.67 TC- 216 lb Conc.Load at 7.01 TC- 160 lb Conc.Load at 9.06,11.06,13.06 BC- 376 lb Conc.Load at 7.01 BC- 94 lb Conc.Load at 9.06,11.06,13.06 Plating Notes (**)4 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Tray Scab(s) (1)2x4x0-3-11 x SP#3 scab at right end.Attach scab to face of chord with:Nails @ 8"oc,plus additional nail clusters at:BRG.:(0),heel:(0),1st panel point:(0). NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (1111'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court.Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.Michael 60839 G Kozlowski 0 391owski PE No. 854gson PE No. Murray14PE No 7 69311 71613 Ply:1 SEAN:20028/T44/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T23 Wgt:58.8 lbs ... / ... 09/25/17 9' + 13'8" 9' 4'8" 1113X4(") C=4X8 T2 D —F 12 4 V M R 99 fM D1 M =3X4('*)B i"3 A —1 I O 10'1"2 F �E III 3X4 1114X5(R) 9'1"12 4'6"4 1'6"8 91"12 + 13'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.057 F 999 240 B 541 /162 /304 /- /120 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.108 F 999 180 E 432 /150 /198 /- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.024 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C - HORZ(TL): 0.046 F - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.836 Bearings B&E Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.641 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.304 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 5 -7 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 206 -575 Lumber Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#1 :T2 2x4 SP#2: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 B-F 471 -245 F-E 477 -245 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Plating Notes C-F 262 0 D-E 104 -132 (**)2 plate(s)require special positioning.Refer to C-E 287 -564 scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 13.67 BC 120 0.15 13.67 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 3-4-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE No.08381owski Jeffrey PE No.58544son o5854gson PE No Derek B71457y usse PE No 7Adam K 7769311 APEX 71613 Ply:1 SEON:20025/T42/HIPM Jo&Brian Adcock Residence Oty: 1 FROM:KS DRW: T24 Wgt:68.6 lbs ... / ... 09/25/17 5'10"8 11' 13'8" F1 I 5'1"8 I 2'8" 1113X4(**) 1)---.4X4E is l T 12 J 4 1113X4 C M o co ; to V 3X4(**)B aha A i 111 _L 010'1"2 G [IF i =3X4 1114X5(R) f`1'6"8 1 674 4 I 7712 J 674 13'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl LHt Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.033 C 999 240 B 541 /156 /308 /- /144 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.063 C 999 180 F 432 /156 /215 I- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.006 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.012 F - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 F Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.362 Bearings B&F Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.701 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.249 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 354 -855 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 292 -873 D-E 0 -9 Lumber Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2 Bot chord 2x4 SP#2 B-G 790 -389 G-F 236 -148 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Plating Notes C-G 214 -315 D-F 255 -397 (**)2 plate(s)require special positioning.Refer to G-D 654 -275 E-F 61 -75 scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 13.67 BC 120 0.15 13.67 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 4-0-3. NOTES: f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. �/� (11:}{ 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer /�- \ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Derek BAPEX TrueHouse PE No.Michael Noel GO Kozlowski Jeffrey No.58544son o58544son PE No. Murray7457PE No 77769311 71613 Ply:1 SEQN:20034/T74/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T25 Wgt:61.6 lbs ... / ... 09/25/17 7' 13'8" • F7' I- 6'8" H 6X8(**) 1114X5(**) C T2 D 12 = T T 4 V (a) c, Co co N ih 3X4(**)B 42 A ______4 O10'1"2 F E 1113X4 1115X7(**) Pr 13'5" -j H 1,6,8_ I 7,1,12 I 6,6„4 H 7'1"12 13'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.074 F 999 240 B 921 /305 /- /- /- /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.140 F 999 180 E 1159 /364 /- /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.023 E - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.043 E - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.820 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.977 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.499 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 -13 C-D 20 -59 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 562 -1847 Lumber Purlins Value Set:138(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2:T2 2x4 SP M-30: to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 Chord Spacing(in oc) Start(ft) End(ft) g_F 1690 -503 F-E 1723 505 Webs 2x4 SP#3 TC 24 -1.50 13.67 BC 94 0.25 13.67 Lumber value set"136"uses design values Apply purlins to any chords above or below fillers Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Webs Tens.Comp. Webs Tens. Comp. Bracing Hangers/Ties C-F 546 -25 D-E 207 -393 (a)Continuous lateral restraint equally spaced on (J)Hanger Support Required,by others C-E 515-1768 member. Wind Special Loads Wind loads and reactions based on MWFRS. (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC-From 55 plf at -1.54 to 55 plf at 7.00 Right end vertical not exposed to wind pressure. TC-From 27 plf at 7.00 to 27 plf at 13.67 Left cantilever is exposed to wind BC-From 4 plf at -1.54 to 4 plf at 0.00 BC-From 10 plf at 0.00 to 10 plf at 7.01 Additional Notes BC-From 5 plf at 7.01 to 5 plf at 13.67 The overall height of this truss excluding overhang is TC- 214 lb Conc.Load at 7.01 2-8-3 TC- 158 lb Conc.Load at 9.06,11.06,13.06 BC- 357 lb Conc.Load at 7.01 BC- 93 lb Conc.Load at 9.06,11.06,13.06 Plating Notes (")4 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Tray Scab(s) (1)2x4x0-3-11 x SP#3 scab at right end.Attach scab to face of chord with:Nails @ 8"oc,plus additional nail clusters at:BRG.:(0),heel:(0),1st panel point:(0). NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (1111r1i) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Flonda Corporation. Flonda Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ��7�_+� G APEX .L 1 ueHouse PE Noel 0 3o�zlowski Jeffrey 5854gson PEFE No.71457y RussellAdam K PE No.77693 71613 Ply:1 SEAN:20037/T81/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T26 Wgt:58.8 lbs ... / ... 09/25/17 I 9' I 13'8" 9' 4'8" T2 1113X4(**) C=4X8 D 12 4 T V V W M M 3X4(,.)B L12 A L7 O 10'1"2 F E _ 1113X4 1114X5(R) i13'5" 1 I--1'6"8- I 91 12 I 4 6 4I 9'1"12 13'8" Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc LJdefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph N:NA Ce:NA VERT(LL): 0.042 F 999 240 B 546 /163 /307 /- /120 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.081 F 999 180 E 428 /149 /196 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.021 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):0.039 F - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.810 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.659 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.298 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 5 -7 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 210 -565 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) 3-4-3. Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#1:T2 2x4 SP#2: Bot chord 2x4 SP#2 B-F 461 -248 F-E 467 -248 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Plating Notes C-F 258 0 D-E 120 -132 (")2 plate(s)require special positioning.Refer to C-E 290 -552 scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 13.67 BC 120 0.25 13.67 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers I Ties (J)Hanger Support Required,by others Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Left cantilever is exposed to wind NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'FI) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 G Jeffrey P APEX Tru eHo use PE No.Michael 60839 Kozlowski P6 No. 544son PE No.71457y PE No.o7 693 71613 Ply:1 SEAN:20040/T82/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T27 Wgt:68.6 lbs ... / ... 09/25/17 5'10"8I 11' I 13'8" 5'10"8 5'1"8 2'8" 1113X4(") D=4X4 E 12 7 12I T 4 V 1113X4 C o . ✓ in . i v 3X4(")B 2 A .. . y. 010x1"2 G III4X5(R)F =3X4 ri 13'5' i I—1 6"8 6'0"4 1 7712 6'0"4 13'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.032 C 999 240 B 546 /157 /311 /- /144 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.061 C 999 180 F 428 /154 /213 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.006 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):0.012 F - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.366 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.661 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.240 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 344 -831 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 283 -851 D-E 0 -9 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 4-0-3. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 B-G 768 -379 G-F 232 -146 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Camp. Plating Notes C-G 211 -308 D-F 252 -391 (")2 plate(s)require special positioning.Refer to G-D 631 -265 E-F 61 -75 scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 13.67 BC 120 0.25 13.67 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/lies (J)Hanger Support Required,by others Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Left cantilever is exposed to wind NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Trif) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fiW\ '11181111111," . APEX Tru eHo use PE Nol 08391owski Jeffrey No.58544son o58544son PE No. Murray7457PE No.7 69311 71613 Ply:1 SEQN:20043/T83/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T28 Wgt:63.0 lbs ... / ... 09/25/17 7'4"4 I 13,8„ 7'4"4 6'3"12 D 1113X4(") _ 12 000000000000000000000001 . 4 p 3X4 C m r bo m o 7.,3X4(")B 4.3 ' il .1111.1111111/ 1.0.1N 0 10'1"2 F E - 1113X4 1114X5(R) PA 13'5" 1 16 8 72"8 6,5,8 I- 7'2"8 I 138" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.026 F 999 240 B 546 /149 /311 /- /168 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.049 F 999 180 E 430 /144 /224 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.009 E - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C . HORZ(TL): 0.016 E - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.603 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.675 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.633 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 35 -72 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 200 -773 Lumber Hangers/Ties Value Set:13B(Effective 6/1/2013) Recommended hanger connections are based on Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 manufacturer tested capacities and calculations. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 Conditions may exist that require different B-F 685 -317 F-E 681 318 Webs 2x4 SP#3 connections than indicated.Refer to manufacturer Lumber value set"13B"uses desi n values publication for additional information. approved 1/30/2013 by ALSC g Bearing at location x=13'5" uses the following Maximum Web Forces Per Ply(lbs) support conditions: Webs Tens.Comp. Webs Tens. Comp. Plating Notes Bearing E (13'5",10'1"2)HTU26 F-C 233 0 D-E 100 -139 (**)2 plate(s)require special positioning.Refer to Supporting Member:(2)2x6 SS Dense (20)0.148"x3"nails inntotosupporting C-E 337 -725 scaled plate plot details for special positioning member, requirements. (11)0.148"x1.5"nails into supported member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 13.46 BC 120 0.25 13.67 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Left cantilever is exposed to wind Additional Notes The overall height of this truss excluding overhang is 4-8-3. NOTES: Nr- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (lirli 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer fit/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo use E No.1608391owski Jeffrey 5854gson EPE No. Murray747PE No 7769311 71613 Ply:1 SEON:20061/T93/HIPS Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T29 Wgt:79.8 lbs ... / ... 09/25/17 9' 11'5" 20'5" F9' ' 2,5" 1 9' 'd =6X8(") =5X7(") C D T 412 „„.,,\.., v eq 0 ro io m 1 =3X4("`)6 Es3X4(") aA _� u . � _010'1"2 G F I113X4 m5X5(") I—1'6"8 1 9'1"12 I 1'11"12 I 9'3"8 9'1"12 11'1"8 20'5" • Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.054 G 999 241 B 753 /241 /371 /- /81 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.102 G 999 241 E 657 /207 /301 /- /- /5.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.021 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.040 F - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.968 Bearings B&E Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.987 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.097 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 566 -1165 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 552-1284 D-E 551 -1288 Lumber Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2:T3 2x4 SP#1: Bot chord 2x4 SP#2 B-G 1152 -451 F-E 1158 -441 Webs 2x4 SP#3 G-F 1156 -450 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. (")5 plate(s)require special positioning.Refer to C-G 171 0 F-D 226 -92 scaled plate plot details for special positioning C-F 255 -232 requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 20.42 BC 112 0.15 20.27 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 3-4-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (PgH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 �+ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX rue Q U J e PE No 60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:20064/T5/HIPS Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T30 Wgt:84.0 lbs / ... 09/25/17 7'II 13'5" I 20'5" 7' 6'5" 7' 6X8(•') ==-5X7(") 12C T2 D T4 (: =•• Vol T M N w4X4(C3) 4X4(C3) " 3X8(C3)B _ Ew3X8(C3) 1 q 1_010'1"2 G F B2 III3X4 m6X8(") I-16"8 6'2'12 5'11"12 6'4"8 1r' I 7'x'12 I 13,1„8 I 19.6", 111 A 111 I 2120'5" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pr in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L./clef' L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.223 G 999 241 B 1624 /523 /- /- /- /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.424 G 569 241 E 1528 /479 /- /- /- /5.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.065 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):0.125 F - - B Min Brg Width Req= 1.9 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= 1.8 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.984 Bearings B&E Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.979 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.210 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): . A-B 28 -13 C-D 1201 -3895 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 1278 -4077 D-E 1287 -4086 Lumber Purlins Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use puffins Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2:T2 2x4 SP M-31: to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP M-30:B2 2x4 SP#1: Chord Spacing(in oc) Start(ft) End(ft) B-G 3816-1189 F-E 3828 -1199 Webs 2x4 SP#3 TC 24 -1.50 20.42 BC 66 0.15 20.27 G-F 3849-1190 Lumber value set"138"uses design values Apply purlins to any chords above or below fillers approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Maximum Web Forces Per Ply(lbs) Special Loads Webs Tens.Comp. Webs Tens. Comp. (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) C-G 539 -17 F-D 551 -21 TC-From 55 plf at -1.54 to 55 plf at 7.00 C-F 49 -12 TC-From 27 plf at 7.00 to 27 plf at 13.42 TC-From 55 plf at 13.42 to 55 plf at 20.42 BC-From 4 plf at -1.54 to 4 plf at 0.00 BC-From 10 plf at 0.00 to 10 plf at 7.01 BC-From 5 plf at 7.01 to 5 plf at 13.41 BC-From 10 plf at 13.41 to 10 plf at 20.42 TC- 216 lb Conc.Load at 7.01,13.41 TC- 160 lb Conc.Load at 9.06,10.21,11.35 BC- 376 lb Conc.Load at 7.01,13.41 BC- 94 lb Conc.Load at 9.06,10.21,11.35 Plating Notes (")3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Wind Wind loads and reactions based on MWFRS. Additional Notes The overall height of this truss excluding overhang is 2-8-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. (1Fit) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer if*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.Michael 60839 G Kozlowski 0 39lowski Jeffrey No.58544son o58544son PE No. Murray7457PE No.Russell 69311 71613 Ply:1 SEAN:20052/T14/MONO Jo&Bnan Adcock Residence Qty: 4 FROM:KS DRW: T31 Wgt:60.2lbs ... / ... 09/25/17 6'9"8I 126 8 6'9"8 5'9" IlI3X4(**)D _ _ i I 12 4 p 3X4 C So 0 v "v 3X4(")B ,gigIfih.„... 2 A N-__ _111...41 101'2 F 1114X5(R)E III 3X4 6712 5'10"12 H 1,6„6 A 6,7..12 -I 12,6.,6 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria 1 A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.022 F 999 240 B 505 /85 /289 /- /115 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.043 F 999 180 E 395 /78 /222 /- /- /- BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.007 E - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.014 E - - B Min Brg Width Req= 1.5 NCBCLL: W.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.525 Bearing B Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.398 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.494 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 39 -62 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 177 -714 Lumber Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 B-F 634 -294 F-E 631 -296 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Plating Notes F-C 216 0 D-E 117 -122 (**)2 plate(s)require special positioning.Refer to C-E 318 -679 scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 12.54 BC 120 0.15 12.54 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 4-6-6. NOTES: .4' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (9111'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ TrueHouse PE No Michae1 0838lowski effrey P Arne pE No 5854gson PE No MurrayDerek B7457Adam K PE No 77769311 APEX 71613 Ply:1 SEQN:20094/T7/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T32 Wgt:117.6 lbs ... / ... 09/25/17 6'1"13 11'7" I 17' I 21'2" 6'1"13 5'5"3 5'5" 42" 1113X4(") E=4X8 F - - 12 03X4 D 1 \ 4 p i lir M o °D r;5X5(*')C O m T1 3X8(A1)B 1' a3 A i Ill Y - � 10'1"2 5X5(") -3X4 1113X8(") I-1'6"6 8'10"8 8'1"8 42" 1 8,10„8 I 17' I 21,2" 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):-0.141 C 999 252 B 782 /1221 /1141/- /151 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):-0.150 C 999 252 G 677 /360 /431 /- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.045 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):-0.048 F - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.766 Bearings B&G Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.961 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.613 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 D-E 1519 -1541 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 3306-3309 E-F 670 -670 Lumber Loading C-D 2400-2432 Value Set:13B(Effective 6/1/2013) Truss transfers a maximum horizontal load of Top chord 2x4 SP#2:T1 2x4 SP#1: 3400#( 160.89 plf)along top chord,from either Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 direction,to supports where indicated.Diaphragm and Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 connections are to be designed by Engineer of Record. B-I 3180-3343 H-G 402 -223 Drag Loads:Force(#) (PLF) Mbr Start End Lumber value set"13B"uses design values Case 1: 3400 160.89 TC 0.00 21.17 I-H 938 -437 approved 1/30/2013 by ALSC 3400 412.12 BC 0.75 9.00 Case 2: 3400 160.89 TC 0.00 21.17 Maximum Web Forces Per Ply(lbs) Plating Notes 3400 412.12 BC 0.75 9.00 (.14 plate(s)require special positioning.Refer to Case 3: 3400 160.89 TC 0.00 21.17 Webs Tens.Comp. Webs Tens. Comp. scaled plate plot details for special positioning 3400 412.12 BC 0.75 9.00 C-I 186 -355 E-H 452 -139 requirements. Case 4: 3400 160.89 TC 0.00 21.17 I-D 402 -105 E-G 379 -682 3400 412.12 BC 0.75 9.00 D-H 309 -659 F-G 81 -114 Purlins Drag loads applied to wind load cases parallel to In lieu of structural panels or rigid ceiling use purlins truss. to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 21.17 BC 34 0.15 21.17 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes Negative reaction(s)of-1221#MAX.Requires uplift connection.See Maximum Reactions. The overall height of this truss excluding overhang is 6-0-3. NOTES: f' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03. should be used in conjunction with the architectural plans during installation. ( }.j) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 "*/\ Tru eHo use P No 1608391owski PE No.58544son o58544son Derek B FE No.71457y Adam K PE No 7 69311 APEX 71613 Ply:1 SEQN:20070/T27/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T33 Wgt:106.4 lbs ... / ... 09/25/17 8'0"1 15' 21'2" 8'0"1 I 6'11"15 I 6'2" 1113X4(") D=4X8 E 12 4 ;5X5(")C in m in 3X4(")B 4' A 0 . . 10'1"2 H G riF 5X5(") =3X4 1114X5(R) I—1'6"8 7'10"8 7'1"8 6'2" • 7,10"8 15' 21'2" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.074 H 999 252 B 782 /120 /432 /- /133 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.141 H 999 252 F 677 /177 /321 /- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.023 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.044 F - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 F Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.646 Bearings B&F Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.763 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI:0.917 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 247 -697 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 488-1470 D-E 0 0 Lumber Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 B-H 1342 -603 G-F 591 -272 Webs 2x4 SP#3 H-G 1339 -604 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. (")4 plate(s)require special positioning.Refer to H-C 227 0 D-F 351 -764 scaled plate plot details for special positioning C-G 357 -802 E-F 116 -168 requirements. D-G 410 -84 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) IC 24 -1.50 21.17 BC 120 0.15 21.17 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 5-4-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,indude BCSI 1-03, should be used in conjunction with the architectural plans during installation. (IT'FI) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Floods Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fit/\ APEX �+ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell Truellu J e PE No 60839 PE No 58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:20073/T29/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T34 Wgt:109.2lbs ... / ... 09/25/17 7'0"4I 13' I 21'2" 7'0"4 5'11"12 8'2" 5X7(") D T2 =4X4 E T --r- • 12 4 uf 3X4C in i Eo m a in 3X4(..)B 12 A ----- Ali LJ I El _ 010'1"2 H G rIF 1113X4 ---5X7(**) 1114X5(") H 1'6"8 1 6'10"8 6'3"4 8'0"4 6'10"8 13,1"12 I 21,2„ Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.074 C 999 252 B 782 /144 /426 /- /118 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.142 C 999 252 F 677 /188 /306 /- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.017 G - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.033 G - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 F Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.806 Bearings B&F Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.813 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.677 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 C-D 368 -926 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 529-1496 D-E 388 -830 Lumber Value Set:136(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2:T2 2x4 SP#1: Bot chord 2x4 SP#2 B-H 1369 -622 G-F 0 0 Webs 2x4 SP#3 H-G 1366 -623 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. (")4 plate(s)require special positioning.Refer to H-C 178 0 G-E 946 -442 scaled plate plot details for special positioning C-G 245 -585 E-F 339 -643 requirements. D-G 175 -210 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 21.17 BC 120 0.15 21.17 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 4-8-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (PirrH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE Noel 0 39lowski effrey P Arne P8 No. 8544son Derek B PE No 71457y Adam K PE No.7 69311 APEX 71613 Ply:1 SEQN:20076/T26/HIPM Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T35 Wgt:109.2 lbs ... / ... 09/25/17 6'0"4 11' 16'1" 21'2" 6'0"4 I 4,11"12 I 51" I 51" =4X4(") =3X4 1113X4(") D E F w•NNNN. ] I T 12 4 V 3X40 om °D a inv .NNNI 3X4(..)B a�'3 A AI 10'1"2 I H pG 1113X4 =5X7(") 114X5(R) I—1'6"8 I 510"8 53"4 10'0"4 5'10"8 I- 11'1"12 I 21'2" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Deft/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in Ioc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.072 C 999 252 B 782 /158 /418 /- /103 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.137 C 999 252 G 677 /197 /293 /- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.023 G - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.044 G - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.303 Bearings B&G Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.962 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.654 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 D-E 446 -990 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 590 -1545 E-F 0 -19 Lumber C-D 436 -1086 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 B-I 1423 -663 H-G 718 -353 Lumber value set"13B"uses design values I-H 1422 -664 approved 1/30/2013 by ALSC Plating Notes Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. (**)4 plate(s)require special positioning.Refer to scaled plate plot details for special positioning I-C 106 0 H-E 370 -116 requirements. C-H 233 -490 E-G 438 -876 D-H 170 0 F-G 82 -115 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 21.17 BC 120 0.15 21.17 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 4-0-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 6111) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi*/\ APEX Tru eHo use Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:20082/T94/SPEC Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T36 Wgt:103.6 lbs ... / ... 09/25/17 6715 10'8"8 14'5" 212" I6,0„15 I 4,7.,9 I 3'8"8 I 6,9" I D=-4X4 = T 12 1113X4(") T 4 12 E=5X5.. F w3X4C �: i (a) r v l � o N 3X4r1B 4_`.3 A I 11'1 111 I 4)10'1"2 H G =5X7(") 1114X5(R) H1,6"81 1088 1- 1058 i 10'8"8 212" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pfin PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.085 H 999 252 B 782 /148 /398 /- /94 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.163 H 999 252 G 677 /165 /268 /- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.028 G - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.053 G - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.718 Bearings B&G Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.972 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.389 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 D-E 510 -1106 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 669-1519 E-F 12 -36 Lumber Wind C-D 506-1124 Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Top chord 2x4 SP#2 member design. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Right end vertical not exposed to wind pressure. Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 B-H 1400 -671 H-G 1275 -624 Lumber value set"13B"uses design values Additional Notes approved 1/30/2013 by ALSC The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) 3-11-0. Webs Tens.Comp. Webs Tens. Comp. Bracing (a)Continuous lateral restraint equally spaced on C-H 238 -431 E-G 650 -1314 member. D-H 460 -133 F-G 131 -194 H-E 212 -314 Plating Notes (")4 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Tray Scab(s) (1)2x4x0-3-11 x SP#3 scab at right end.Attach scab to face of chord with:Nails @ 8"oc,plus additional nail clusters at:BRG.:(0),heel:(0),1st panel point:(0). Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 21.17 BC 120 0.15 21.17 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: .11- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. �/� (Iiiii4 2.Apex Technology is a fictitious name owned by Jas Apex Technology Inc.,Florida Corporation. Florida Engineer if - \ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 / APEX Tru eHo use PE No.Michael 08391owski PE No. 854gson PE No 71457y PE No.7 69311 71613 Ply:1 'SEQN:20079/T2/SPEC Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T36A Wgt:109.2 lbs ... / _. 09/25/17 6715 10'8"8 12'5" 167"12 217" 6,0"15 I 47"9 I 1'8"8 I 4'2"12 I 4'6"4 Dm-4X4 1113X4 -i- 12 12 $ E 14X5(**) F =4X4 C' 4 V � N". .i. T �3X4C I. r v "v 1 r0 ' 3X4'*B1 ❑ 10'1"c =5X7(") =4X8 III4X5(*`) 10'8"8 511"4 46"4 1 H-1,6„8 1 I 10'8"8 16'7"12 21'2" Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl LJ# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.072 C 999 252 B 782 /154 /407 /- /96 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.138 C 999 252 H 677 /183 /281 /- /- /2.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.021 H - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.041 H - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 H Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.376 Bearings B&H Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.938 Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI:0.375 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 D-E 500 -1073 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 653-1515 E-F 381 -822 Lumber C-D 487-1110 F-G 381 -822 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 B-J 1397 -687 1-H 6 -3 Lumber value set"136"uses design values J-I 1139 -530 approved 1/30/2013 by ALSC Plating Notes Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. (**)4 plate(s)require special positioning.Refer to scaled plate plot details for special positioning C-J 241 -435 F-I 175 -281 requirements. D-J 492 -167 I-G 986 -456 J-E 162 -293 G-H 329 -654 Purlins E-I 185 -390 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 21.17 BC 120 0.15 21.17 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The overall height of this truss excluding overhang is 3-11-0. NOTES: f- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fil\ Tru eHo use Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell APEX PE No.60839 PE No.58544 PE No.71457 PE No.77693 71613 Ply:1 SEQN:20085/T12/COMN Jo&Brian Adcock Residence Qty: 2 FROM:KS DRW: T37 Wgt:89.6 lbs ... / 09/25/17 6'0"15 10'8"8 15'4"1 21'5" 60"15 I 47.9 I 47 9 6'0"14 D=4X4 -1- 12 12 4 V 3X4C Eg3X4 e o 1 �'3 A=3X4("')8 F=3X4(*`) EN 01012 5X7(") 1,6„8 1 I 10'8"8 108'181 10'818 21'5" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.086 G 999 253 B 785 /251 /384 /- /93 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.165 G 999 253 F 690 /217 /314 /- /- /5.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.029 G - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL): 0.055 G - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 F Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.375 Bearings B&F Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.998 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.236 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 28 0 D-E 472 -1134 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 B-C 628 -1529 E-F 641 -1545 Lumber C-D 461 -1133 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bat chord 2x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 B-G 1409 -546 G-F 1428 -549 Lumber value set"136"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. (**)3 plate(s)require special positioning.Refer to C-G 243 -433 G-E 254 -454 scaled plate plot details for special positioning D-G 470 -135 requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 21.42 BC 104 0.15 21.27 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 3-11-0. NOTES: ,4' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61}{) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ,*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Trueouse E No.1608391owski Jeffrey 5 544son FEPE No. Murray71457E No.7 69311 H 71613 Ply:1 SEQN:20088/T10/HIPS Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T38 Wgt:84.0 lbs ... / ... 09/25/17 9' I 12'5" I 21'5" 9' 3'5" 9' 6X8(**) T2 5X7(**) C D T 4 E., -- 1/4\71 12 r i 3X4('')6 _\ 3X4 , 1 TT._ G u II i 010'1"2 G F 113X4 m5X5(**) I--16"8 1 9'1"12 I 2'11"12 9'3"8 9'1"12 12'1"8 I 21'5" 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria A Maximum Reactions(lbs) . TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.060 G 999 253 B 785 /252 /386 /- /81 /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.115 G 999 253 E 690 /218 /316 /- /- /5.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.024 F - - Wind reactions based on MWFRS Des Ld: 32.00 EXP:C HORZ(TL):0.046 F - - B Min Brg Width Req= 1.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 E Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.804 Bearings B&E Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.982 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.094 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): ,A-B 28 0 C-D 605 -1251 Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 , B-C 594-1370 D-E 593 -1379 Lumber Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#1:T2 2x4 SP#2: Bot chord 2x4 SP#2 B-G 1234 -491 F-E 1244 -483 Webs 2x4 SP#3 G-F 1237 -490 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. (**)5 plate(s)require special positioning.Refer to C-G 182 0 F-D 203 -63 scaled plate plot details for special positioning C-F 246 -218 requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 21.42 BC 108 0.15 21.27 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 3-4-3. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo u se PEE No.l 60839G Kozlowski Jeffrey No.58544son o58544son PE No. Murray747RussellAdam K PE No.77693 71613 Ply:1 SEQN:20091/T25/HIPS Jo&Brian Adcock Residence Qty: 1 FROM:KS DRW: T39 Wgt:91.0 lbs ... / ... 09/25/17 7' 14,5, 21,5„ 7' 7'5" I 7' 4X5(") =4X5(") 12 C D T 4L T_ 0 N 1 =3X4(")' i --".111111111111111111111111 it ipliligik‘ ==3X4(") ih A - w F 1 10'1"2 'G F ///3X4 m 5X5(1 57 j 9'7"8 j 5x 12 '� 12 �-1'6"8 5'10"12 I 9'3"12 6'2 8 5'10"12 15'2"8 21'5" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.037 F 999 240 B 526 /47 I- /- /- /5.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.059 F 999 180 G 392 /619 /- /- /- /5.5 BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.019 F - - F 269 /379 /- /- /- /5.5 Des Ld: 32.00 EXP:C HORZ(TL):-0.031 F - - E 193 /103 /- /- /- /5.5 NCBCLL:10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:1.5 Wind reactions based on MWFRS Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.894 B Min Brg Width Req= 1.5 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2007 Max BC CSI: 0.880 G Min Brg Width Req= 1.5 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.220 E Min Brg Width Req= 1.5 1.5 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: E Min Brg WidthReq= Bearings B,G,,F,,&E Fcperp=565psi. GCpi:0.18 Plate Type(s): Wind Duration:1.60 WAVE VIEW Ver:17.01.01.0630.10 Maximum Top Chord Forces Per Ply(lbs) Lumber Tray Scab(s) Chords Tens.Comp. Chords Tens. Comp. Value Set:13B(Effective 6/1/2013) (1)2x4x0-3-11 x SP#3 scab at right end.Attach A-B 28 -13 C-D 377 -229 Top chord 2x4 SP#2 scab to face of chord with:Nails @ 8"oc,plus B-C 0 -509 ID-E 306 -236 Bot chord 2x4 SP#2 additional nail clusters at:BRG.:(0),heel:(0),1st Webs 2x4 SP#3 panel point:(0). Maximum Bot Chord Forces Per Ply(lbs) Lumber value set"13B"uses design values Purlins Chords Tens.Comp. Chords Tens. Comp. approved 1/30/2013 by ALSC In lieu of structural panels or rigid ceiling use purlins B-G 427 0 F-E 426 545 Bracing to laterally brace chords as follows: G-F 360 80 Chord Spacing(in oc) Start(ft) End(ft) (a)Continuous lateral restraint equally spaced on TC 24 -1.50 21.42 member. BC 75 0.25 21.17 Maximum Web Forces Per Ply(lbs) Apply purlins to any chords above or below fillers Webs Tens.Comp. Webs Tens. Comp. Special Loads at 24"OC unless shown otherwise above. (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) G-C 463 -134 D-F 331 -253 TC-From 55 plf at -1.54 to 55 plf at 7.00 Wind C-F 153 -534 TC-From 27 plf at 7.00 to 27 plf at 14.42 Wind loads and reactions based on MWFRS. TC-From 55 plf at 14.42 to 55 plf at 21.42 Left and rightexposed to wind cantilevers are BC-From 4 plf at -1.54 to 4 plf at 0.00 BC-From 10 plf at 0.00 to 10 plf at 7.01 Additional Notes BC-From 5 plf at 7.01 to 5 plf at 14.41 BC-From 10 plf at 14.41 to 10 plf at 21.42 Negative reaction(s)of-619#MAX.from a non-wind TC- -45 lb Conc.Load at 7.01,14.41 load case requires uplift connection.See Maximum TC- -52 lb Conc.Load at 9.06,10.71,12.35 Reactions. BC--257 lb Conc.Load at 7.01,14.41 The overall height of this truss excluding overhang is BC- -54 lb Conc.Load at 9.06,10.71,12.35 2-8-3 Plating Notes (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 611-H 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 GAPEX TrueHouse PE Noel 0 3o9PE zlowski rey P No PE 58544o. son Murray145771457 PE Adam 7Russell