Loading...
1769 ATLANTIC BEACH DR - PERMIT iii ,, , s� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD uvip ATLANTIC BEACH, FL 32233 -''%Ji319' INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0009 Description: new single-family home Estimated Value: 456744.35 Issue Date: 2/12/2018 Expiration Date: 8/11/2018 PROPERTY ADDRESS: Address: 1769 ATLANTIC BEACH DR RE Number: 169505 1475 PROPERTY OWNER: Name: ADCOCK BRIAN J Address: 14560 ISLAND DR JACKSONVILLE, FL 32250 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: OSSI CONTRACTING LLC Address: 13349 STONE POND DR JACK OSSI JR JACKSONVILLE, FL 32224 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. .6= Permit Conditions ri -5180 City of Atlantic Beach 13>Y Permit Number: RES18-0009 Description: new single-family home Applied: 1/9/2018 Approved: 2/12/2018 Site Address: 1769 ATLANTIC BEACH DR Issued:2/12/2018 Finaled: City,State Zip Code:ATLANTIC BEACH, FL 32233 Status: ISSUED Applicant: <NONE> Parent Permit: Owner:ADCOCK BRIAN J Parent Project: Contractor:<NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 1/11/2018 EROSION CONTROL INSTALLATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(247- 5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 2 1/11/2018 ON SITE RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site during construction. 3 1/11/2018 ROLL OFF CONTAINER INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapell's, Inc.,Republic Services,Donovan Dumpsters). Container cannot be placed on City right-of-way. 4 1/11/2018 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. 5 1/11/2018 RUNOFF INFORMATIONAL • PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site. Cannot raise lot elevation. Printed: Monday, 12 February, 2018 1 of 2 t 1i1 Permit Conditions City of Atlantic Beach 6 1/18/2018 UNDERGROUND WATER SEWER INFORMATIONAL UTILITIES PUBLIC WORKS Kayle Moore Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5834. 7 1/18/2018 METER BOX SEWER CLEAN OUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible. 8 1/18/2018 RT1 SEWER CLEANOUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. Printed: Monday, 12 February, 2018 2 of 2 51,1\,\.,;.e., City of Atlantic Beach APPLICATION NUMBER :s ilk ,�, Building Department (To be assigned by the Building Department.) - 800 Seminole Road V_LS IS — 000 ist -r Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 • Fax(904)247-5845 I� I �1 �? E-mail: building-dept@coab.us Date routed: I l Li it 6 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: rt (D GI kt'-1-1& y±,(__ e.itL. 0(. Department review required Yes No �r 2iIding u Applicant: D-SSI C-0OA (GIC. J1( I na Hing &Zoning Tree Adminis ra or Project: Nt .,J S‘Ste _40\k, VOAJL ork---.) Public Utilitie_se Public Safety Fire Services Review fee $ Dept Signature U?) Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By L Florida Dept. of Environmental Protection L 1� Florida Dept. of Transportation -. St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. Xenied. ❑Not applicable (Circle one.) Comments:s,f-e ficifi 1 iv(✓e da .1-c n` A,- A t/ A- BUILDING o`Ve(hA.(1 PLANNING &ZONING y� Reviewed by: __/s- -- Date: (._ / 41—/ TREE ADMIN. Second Review:XrApproved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES 2- K- 1 ? PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Earth Works, Inc. 12501 Beach Blvd Jacksonville, FL 32246 ‘4\ IgA palnhus(15) C lebratio d 795 s.f. nGV� !LI .111 4"Cal.Live Oak(1) \ IN't �J1+ 30g Ligustrum atio Tree(1) 04‘InV41O 3g C tie(10 / I toy EARTH 041 3gMuhly Grass(8) 11 Pd 1 ¶• �— vl(v vi WORK r ►� GARDEN CENTER 1a '; _�r 3g Muhly Grass(10) 4 •nII ' •r 34�c�* 3g Pineapple Guava(2) \ fo,;y‘ -- — Ig African Iris(12) I�.�° 4 --,-3g Indian Hawthorn(6) i mili 18'C.T.Min Sabal Palm(1) ]l\61 3g Coontie(14) . \t (v Atlantic Beach Country Club 18'C.T.Min Sabal Palm(1) r . (Lot 36) - A. �, Maritime Oak Drive , Atlantic Beach,FL o 1 • 1t� LANDSCAPE CALCULATIONS: 9 3g Walters Viburnum(10) �I`, 1.TOTAL SITE AREA 6,799 SF .11 AC 16'C.T.Min Sabal Palm(1) `NoNODate: December 5,2017 i1Drawing Scale: 1"=20' (1(61-t)O LOT 36 • 2.FRONT YARD REQUIREMENTS: Designed By: Earthworks.Inc _ YARD AREA: SSS SF Revisions: -1 16'C.T.MM Sabal Palm(1) ~� LANDSCAPE REQUIRED(40%OF YARD AREA) 395 SF - LANDSCAPE PROVIDED 740 SF O"- TREES REQUIRED(1 PER 750 S.F.)(5O%HARDWOOD) 3 TREES PROVIDED 10 TREES • to 3g Walters Viburnum(13) 0 • 3.SIDE YARD REQUIREMENTS: ISI'My. Sabal Palm(1 • YARD AREA: 1,158 SF 3g Pittosporum(8) , O LANDSCAPE REQUIRED(30%OF YARD MEA) 360 SF ' LANDSCAPE PROVIDED 1,000 SF i, iS. 4.CITY TREE REQUIREMENTS: 14'C.T.Mut Sabal Palm(1) •'i 4 r . ,TREE PER 2,500 S.F. 4,723 SF �� lg LI'lopg(S)i _ e 111'lope—. (15) _.. Mi 0 TREES REQUIRED: 2 �, _ d TREES PROVIDED 12 TREES Q 0 —t i � - ^` _. ' CC 3g Pittosportnn(14) - - ; I -roo.o�oa�a �.r' - g P ( ) NOTES: 1 Lu10 a 15 _ 1.MULCH MUST BE PINE STRAW 30g min.Crape Myrtle(1 ` ! ':i4,...„:;74,,07 ,\lg African ITIS(28) —2.BUBBLERS AT ALL TREES A PALMS y : 3.ALL SABAL PALMS MIN.14'C.T. islg Asiatic Jasmine(48)Ig Foxtail Fern(1O)'. 4"Cal.Live Oak(1) ��MEET TITLE y ..--T-• -'^"' o, '^' Lot =6,768 s.f. 65% =4,399s.f Planting Plan L...., .__ Celebration Sod , - Current =4,011 s.f. 723 s.f. Celebration Sod Free space=388 s.f. 176 s.f. ____ L-1 ) f SHEET f) rSITE PLAN LOT 36 AS SHOWN ON PLAT OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67, PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FL. GRAPHIC SCALE Tie61,, +B JD ( 1N FELT ) 1 inch = n COMMUNIT1�pE�� \�\ EL OPMENT \ (o' NO. Aar .r\ et., UN\ se 0-1'N Q ; _Alp+.(.4-A: , a � • �� �a , t ' ��♦' jA ,,fib .i � . O. CD Me \ Z+L1Ir \�,�'%....,,Z _,...,4) enc \ SOW \ \ ti J \ Y \ \ nemso RT nod T.of mum NYR antra.'WAY MO la MHT MY \ \ MUNN rex a1 Pmol To NAM a RST a6 Mr.0311,00.1/00.1.-1.1T.0021IE 1MUMS +y7_ WerAYIKFI TO MX OFI .MAIM TRIO \ 1� \C\\ 1.BEAMM ANE BASED M THE 0110311E Cf ATLANTIC 8E001 DRONE AS BAD S32.41'16'E \ \ 2 DOM ONCE ELEVATE.SNOW HEREON ARE BASED M NAY°060. \ 1 TIELANDS 910M FERMI. EI IE DEN FLOOD 00E X RAM 11 AS CIEO E FLOOD INSURANCE RATE YAP \\ URE) MWI CTY SLIM.120075,PANEL EL 04001,DATED,ANE],2013.TIE ROOD DBMOM OM V 6 RAN ME SCALED OT Cr TE FLEAMA FULL.MAPS MID ARE FOR REFEIECTEV TIE FLAY. INFORMATION A.110A.110DELEATNNS MMB SITE PLAN ID CM,ARE RAFOR DATES IP 10 MC NCUEYN•114E EWE OF TES 9E RAN THERE YAY NAVE BFL11FNT 1.4906906 TER)46 DATE THAT tri 0E SAD INFORMATION. 011 ATIO.INaES SH1BE RADE TO 11RE01 EE CIIETYS FLOM RAZE EIMMODENT NPOS1011.IMY, DEPARTMENT OF PIRLC BORNS 4.FLOOD MA"REFERENCED IEIEM ARE BASED 0 NAM.1.e1 ® DENOTES PROPOSED PAVERS 1 NO L10)4 0A 4 0 FOIWA0M3 OR OWES t NO BPREMSENT5,MIEN TIIAN THOSE MOM NOE LOCATED Nam MD.TLE SCOPE OF LMS SIZE RAIL yB�e�'':'TT�t•!��'+�+�'S�-.11��I MAR MEM ROM 0105 L AJa TOS DEEM.ARO/..ANY Mr.IfiAYATCM ADDED TO D6 MAP MD/OR REPORT a P.a61ED 1 ""1 DENOTES PROPOSED CONCRETE r AND B NOT MINORZED OY DE]Alla SIRIETTR 1 - 1 7.nes MAP IS MENDED 10 BE METED ATA SCALE r 1'-3G oe SMALLER B.MIRES A PAINS DEPICTED AS ESTIMMC IAD 1IE BUILDING RES'TMCDON LYR WST RERAN UNCOMBED A/ 0 DENOTES CHEMICAL TOILET IDT p1°DSED. IMPERVIOUS COVERAGE L 1001001 ENTERS ADJACENT TO 1EIMOS ARE TO 1204.NATURAL.MECE1ADME,MO 0OISRR1ED. C- DENOTES FUTURE 4. TREE 16 DIMENSIONS NEN FEET AAD MEDIAL PARTS THEREOF. DEFENSE.S4 R LOT Sq.R S 11.LMS SITE RAN IS ONLY FOR DELNIDS AS DESCRIBED.IT IS NOTA CERTIFICATE OF MIND.E.MIM EASEMENTS CR FREEDOM 0 EN 10010 Q4 4,200 SR.R 4724 Sq.R 624 MS 12 TSLE FLAN WAS NOT MOOED TO CELEATE CR DEFINE ANY FERAMS,ENNROM LY SONSMSE AREAS MANE HA90A4S M 1. 0C11MAL LIES a ANT MOM_STATE.REGIONAL M LOCALLOCAL MRAL OLY, UNE TABLE YM BOMA MO Oa6SM M ODER0 ENTRY MD ANT LLANUTY 11144Aie10 11EIEFROM IS NOT DE RESPONMLITY OF TIE 1 MO*000*. ONE 0IM RECILOOM MLESS A COPrmDN IS MADE,SEAWEED WARMS AND°meas.ARE CE TICAL MTI RAT VALIES BUILDING COVERAGE 14.D6 SITE RAN R BASSI M NFOBIAIIM AS C 40101TOED BY THE RN. (P) NTI11.32141.16,0 UM11 SLED.A/0 IIPROMOENT TES AS OEPIC1ED IUEON ARE PENDIONAR TO TE PARCEL REPENT'MES COWED Sq.Ft LOT Sq.R i 16 PLEASE TODEMRSE O TIE PLAT MR TON mases THAARE MOM T wr T S LOT. 3,370 SR,R 6,724 Sq.Ft 00.1E FOUNDATION. L2(P) 11241'10'1 CLOD 17.TO IS NOTA 0BOUNDARY00001 SR,EY. It P 4041 I2 HOA OEPICRED I.E.ARE BASED M DE CVL CO 4MIC EN PLANS 11E1 ME MOM FOR N FCMATMAL 06000 Ott AMO ME NOT TO BE RUED IPM FOR C06TROCDOL FOR CORRECT LOCATCII AND/CR 1 011. 15 REFER m TE MOST atl101T SLT Tr ow ATA 41100 .FUNS DERE IS A MAMN M DE SLOTE COUNTY MEI ADA Sr MOAN RS dSEWN. M.SHALL ALL 01 NO ALE MORE 14 SE DIE PORTION GIF 111E�WEINAUE wet ITIMISVERSES CURVE TABLE 04X1101 RE01AY APRON 91011 ALSO MPLEASE MEET DES MCAMMENT. SO.PIENOTE 1110717TE11FS(LITER • HRH..LAC)91 NOT BE NSTALIED SOHN THE SIDEWALK CURSE CURSE RARARE LFN°M MOD DNECIDN 010/111 LENGTH UTA 1L 41401(E 1.) 1 smut-mews°MI ED MAY AMY N WEE. TEM 10 010EDE C PLANS FOR COMER Cl(P) p100 56.63037421 04 sem M19`'4Y 2D 1.A/C 07 2A/C PADS YOST NANTNN 2'AWAY FROM NII PROPERTY IPE.NO CAN MOT ENCROACH MTD A OUMAL2 4S $417E ®]SL 1 071'30' EASE/ENT WE TO DEMME PURPOSES I22(P) TaloaN PREPARED FOR:OSSI HOMES cE1m?IEn TEN OSSI HOMES .=o = t 1 BAR TRAM TRAIL SURVEYING, INC. 4 `z =r= LAND SURVEYORS - PLANNERS - lam DEVELOPMENT CONSULTANTS __ 1601 COUETY ROAD 515 SUCIE NO. 101 904 264-2224 �_ RI GREEN COVE SPRINGS, FL 92043 FAX 901 284-2266 .—� CERTIFICATE OF AOTHORIEATION LB /E 1 COPYRIGHT m 2017 ',G°- 'T�"i FINAL 1E NOTATION: FLaFiO 20 Qom-_ S 'I 0(L HEREB1 CER-FY.Mee NY M Mly Drap4'caly'4OrmE1L 1r Th.survey hereon °I made Without benefit of abstract or 0/0IOL 2(N/A) W"-- " •�" the rosy to of o add y made under my regma1. MOrth of UM.and therefore M.undraf1ed and B0bam __ direction Old compile.meth the Wee Standard.of Trail Surveying nook.no Certifications regaden information PAIL 110.: Q Practice for Surreys id.promulgated by the FlorStot. 1100°ar not*10Oearns-It;hr.o°pert inln to BansIt dolma 120073 04,36,{e/3/'J r,—y' � !'• +. Board Al Professional Surveyor.and Mapper.,CDa0ter of ..monk Right.-of-ray,rtbodr line.,overlaps, 7. 1,.. «- i% 5J-17[.AC;Pursuant t°section 472.027,Florida Boundary tine dOpute.,00,90lnk tbn•or other �� N/A statues,subject to el notes and notation..horn hr40 aon. 00 matter.Mid,may spa In In ter abstract r march. K mer N/A N/A ThY rvey I.pr.por.d old rorflfled tor the mdueiva of �M 12/22/17 SCALE. ,'�3ry • p `� "7, .. FIELD MOfO(COMPLETED MAP QUONAA Y SN,TIED MI d)nt named hereon old the rvey and 09011 of the oopl..*wog are not valid Without the Y9natun and P(l0 CT Na: REVISION: N/A the e001nd raised s.d of a Florldo Ikn.ed NNrnyr and 110117-003 THOMAS P.HUGHES,P.LS. e1Opper' STATE DF FLORIDA LICENSE NUMBER LS 3507 DRAIN Er.ODM DECKED BY:WC 91EET 1 OF 1 CITY OF ATLANTIC BEACH 800 Seminole Road �b Atlantic Beach,Florida 32233 fr�v _ems. REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date z/ 2 f/( Revision to Issued Permit Corrections to Comments 7 Permit#RC S( O 000c Project Address (76�( ,�-t- . <t _zr - Contractor/Contact Name r,S. 5'S Phone 5 r -b 7 v Email lillctvk eG S S dL✓r-1 yt,4-�,->L, Description of Proposed Revision/Corrections: Permit Fee Due $ ADD1 .-“f "IIPTrar- r"?/(,-- 1;ortArt-Nze4 4-5 Additional Increase in Building Value $ Additional S.F. By signing below,I I)`'( !k v. affirm the Revision is inclusive of the proposed changes. (printed name) / Signat a of Contrac r/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to PP r PP Department Revision/Plan Review Comments Department Review Required: Building arming & ZoniE• Reviewed By Tree Administrator Public Works — - ' U Public Utilities Public Safety Date Fire Services 4 - "1 CITY OF ATLANTIC BEACH � 800 Seminole Road 1;,) Atlantic Beach,Florida 32233 s w h.f:ter REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date (t'2)1/I Revision to Issued Permit Corrections to Comments Permit# 2E S i 8 -mock Project Address 1'16 Q Ak C- r Contractor/Contact Name C.:,55 j c c cD SS Phone etu`t L 5=-(-— C'3 d Email Description of Proposed Revision Corrections: Permit Fee Due$ /h4 ( c 4.. 1 CG., '"sr__ 1 c o[Ot L- 4 F l c c S P 1...-e_ Lr. !/Vu, „ /�e� �✓ c-i— ,(7 ( 11 Additional Increase in Building Value $ Additional S.F. By signing below,I D.7 6a1._ affirm the Revision is inclusive of the proposed changes. (printed name) / Cr ignature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: :uild iii, ' arming & Zoning > Reviewed By Tree Administrator u is Worc S �-� p LA ND ublic Utilitie �— - I Public Safety l-PLAiL) Date Fire Services ze— .0�.MOM(00,011K. cJC,Y Inc. ii -...."....RIM Yellow Star Ln N IF---- Jacksonville,Florida 32224 • 904-716.6335 ® to 2017 Ogy Design Inc, o 0 . OSSI HOMES 1--- STRUCTURAL Q �l ■� /ppm STRUCTURAL CONSULTANT. APEX STRUCTURAL ENGINEERING SUTTON SUTTON PORN COURT.SUITE 401 a. ® - -1 11001W vIlfil 9049115100 EL 311N 80.B11 51110 3113 C3 INo. Description Date U \, _ _ TOPOOET REF;P.11:m0s a 'Ill \411111111111 11, -------------- ...• `u" 'OK'M N., " Jo and Brian MOAN Se%FOR M ;u .T,a.11.1419.11.11f mon BM Adcock Residence .0,..50:,.ANA 16 a<w" R ABCC lot 36 ROOF PLAN � , � . , SME.1�..11•� __, Prole..Number 2017.8.5 ROOF VENT AREA ime* MM. ,,.ry+...�.. '"'"`"""'""" °"° 10/19/17 .o,o"rvo. Drawn By Author 9.,.0...00 CALCULATION aROOF PLAN cmd.der checker 1 A201 s. 1/4"=1'-0' Not -i :t co,om Nor, r':, I COY 1 r roc. Me0..<..101.-— f Yellow Star Ln N Jacksonville,Florida 32224 O ! 904-716-6.135 Q iti 1 e 2017 Ogy Design Inc. iii 0 , • e41 i OSSI HOMES STRUCTURAL CONSULTANT APD(STRUCTURAL ENGINEERING SUTTON PARK COURT,SVITE 001 ® - MIDD/11 IC fala w.l!1100 NW.Irma 1 IM .WCH215200 .PL 3]]10 901 8115100 r ` ,.o.,,colo»rvo.r 3022 ..- • No DesalptlanDaie - i • 3017 11 ILIy u_LeluG r.e ,e ww®.0.4 ° •- ... .nommen. i nie...,e.uN Jo and Brian �.� 9..11.261 a Adcock Residence' MROAM So. OAN SA�A.Y,I�.00. RA•KIn ABCC lot 36 ..4.N...4.TPOO.4..aROAN.FP brilantli0Of ..:. .,,„M 1,10,14•13,1q n .5 ROOF PLAN M.....MA./D.1.15,.,4SPONAMP.C,RIta, REC41.0.411101. l- PntectNu.Mer 20!7.8.5 ROOF VENT AREA .... .e.�a ...»...•.. ro.1 1.'"`111"".”' Date 10/19/17 co,..,.. Dr...By Author CALCULATIONO ROOF PLAN checked By 1N'=1'-0' 1H'=1'.0' _ Checker g A201 ISITE PLAN LOT 36 AS SHOWN ON PLAT OF --.....\\ ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67, PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FL. GRAPHIC SCALE 30 0 10 b ( DI ) 11nch COMMUNITY DEVELOPMENT /\ / 1PPROVED \ •\ \ \ \\\ 1� •`Q/ �� ,SPL ��.. 0 a "o 14 t. ds is \ °°° eA ao' :\ A"�' JAN 1 ?018 `���lJ + 1.b CFI ...�V $: ,.� ��Q ♦N,,I � & ie //, lac CD \ mar C:',. If 1%11''. \\ c SILT FENCE n.4r ,I,a (TVP) b �. \ y\ (Q 7 \moi1, 15.30 \ '.7( "' \.._...1.\,.. \ MONT-la NET MOM FO6 6 OM./0 ON.OF WOO OF NO,FID IS RFT FOOI OMAR MX OR M.TO WM 6 Mort OF OM MO,CONOOTOOME-marte. \\CA\\ I.REAM.ARE ELASEO d ME mROeIC 6 ANN=EAOI OWE AS 9010 3.32,1,rE \ \ 1 NMAI,A.E...Anon 9091 WW1 AM WED d NASO Iesl \ ((1 LIE LAOS 9100 491E0.lLIEWM RECO 709 Y AS 0@IRm 0 OE 11.130311.1303 112104 RAE YAP \ eA91))F 0.1.10120015.4/EL TIEraYA 1E SVdID 6F ilNNE E ORM.uE 1 2013 TIE FIJI.0013 9091 d \ W01111,1011 NO 0130071319d 1101 SE SLAM,1I VMS OILY E01 DRAMS W m AM NIGltl10 11(DATE 9 P 10 RAY I1uRAT HARE 00 .0 NW 5110Re1SR AFTER.5 NATE THAT aLL S0311�540 lswlA aT OL 1.1.01.093 0.5.0 E eAE TO TIE aSrR0111 mom PURE 110..0010E1 IEPOlRRY. AMNm YAPS 91001® 0MIL PIED OR Me Ira DENOTES PROPOSED PAVERS a 210 I.OEwa11O m.aATOe a ufJRS•10 0P00St10.VnER TMN TRO€000 MOE lacers ,.. .'. THE SCORE .5py ROE]MOT5N1 sr.A1`O eco lEmund MyAm ro T1s5 Yr AMD/d RvaT a 1�em Ej DENOTES PROPOSED CONCRETE R>•' SO 51.101109 ACK sow ).INS.WS 9 1RdoE0 TOE WED•e A SCALE or 1,31,a 910181. ��Y10 IL 1311ES a SAMOS 051933 AS ExTENOK PITO TIE euluc ROORIC1101 U1S1S as,191101 Ilrn7.0101• ® DENOTES CHEMICAL TOILET 107 00001 S 10in METERS WIACIN1 m 51100 REWNW,wa AE TO RAN .MOnA1TE.Ar 0101911.911910101911.0101911.91191. 0 e . DENOTES FUTURE 4- TREE IMPERVIOUS COVERAGE t0 004 a NE IN RFT API ova.E PARTS 103 PIE. IPa1nn 91 n LOT 0.n. s 091311303 OR SITE R 11EIDO0Y•OF 101 00011933. O 0..101 A5 N .IT NOT A C iPiCAiE 6 TOlL K ID319 S.Et an*So EL illi II VW 51E PLAN INS MOT 1111310E13 TO 911941E a 06K WY 51005,EMMOOBITMLY 510111E MEAS,{AYE HAa1An a MOOMICTIOOAL LOCO a ANY 1103104,SIAM 090301 ON,ax Amo+, UNE TABLE swam MO 401/03902 OR 5110 ENT10 Ar 0(1 WIMPY RE9LT10 Nownsm 9 Ise aE RE5f01001V 13 114E 010E019913. ONvuaoa a.WOE.MEw150 95 4001No MOW.AE axla*L 101 PLAT V041 ll[ 5394502 Loom BUILDING COVERAGE IL Ml SOC 0..W 0 4903 01 MTRWnd AS•sosm a ME CLEW LOQ) 1MT410r9 1103 Ice CCO 20 NO a MOM. 0411 TEs AS 0011CIm 1a0E01 AE P€1 000LM 10 11E REM.PROM,LOCO COWED!art LOT S.0. ■ 111033 at EAE TO M MTENtRADDII�WU ITAM EMTO S NT 1NY 019 LOT. �) s�M10'E e603 ,yll0 So.n 0791]art Sea nee MOT A 1(0 STCT SUM, in 1V PORK SOFFIAKS EFICTE1 IE]Ed AE WED OM TIE Ola WPala1CM.RAM PEY ME 91091 1FOR S MNp01.1aMLL RAsoS[s COLT AMD ARE MOT t0 E ROOD WM FOR 001.1.0101. FOR CORRECT LOCAT01 SaO2.w1 01.5 REE Au 01.E W S4T SET r F Co AT wales RAMS. o1�1r 9 A Akio rad STMOMOS.01053 SLOPES 9101E 0 SORE TRAM a M MOW OF TIE WEewx WON 114901001 CURVE TABLE TWO.OE CI EARY 0I101 901 090 WET 1215 IEd110Orr.Map.PIFAY MOTE TMT IROIES(ICIER POES.vMMa STALL ROT E M:TM11D EMPI TIE 91E19.11. ORE RAMS 3I10 111011 000 MILTON 0013 LOW% DELTA a MNIAE 0091103 NAY vARY N SOE RTER 1D 90111111010 RAM FOR COIECT C1(113 40303 9aLl 1130.001 INS STOWA. 5051956 FAY3,A d P 011E iO TtIRA11YE 011593 f1aAM 1 Y PROPERTY LSE CAN NOT fM NOOd 11!10 A COMARE COQ400in 00 a SerbIll E Me 01731" REVISOR 0 HEWED 9E RAM-ACM MARY 001010(1123110)(OK) UPDATED 0215E(1/6/0)(D ,10) PREPARED POR:OSSI HOMES =WPM TO:OSSI HOMES ---- �--- , , BARTRAM TRAIL SURVEYING. INC. ,___,esi�'ir'i'iT...� �..� I1ND 9DHYiYOR8 - PLANNERS - LAND DEVELOPMENT CONSULTANTS ��( •_'S� gli ver•_ 1501 COUNTY ROAD 816 90R)< NO. 106 904))))284-2984 �/ R-�2 .-°S� ,....�. IAA GRIME con C[RTWIISP17 OF AUTHORIZATION 3204E PAZ.ATION LB(/9991 904 284-2245e 1 Mr:7-A•'--' COPYRIGHT 0 2017 WI!32 lli ver-- NOTATION: E.1,Ew.11003 rot x(N/A) rear, esu 1 HEREBY CERTIFY,Nat NY survey graphically rpr000 The sunny Irani Ras mads.121211 er.m of abreact of E/ELL-VMS:en ,_Elsresuunderp91qv, u results of a fled survey mods under my re0se . of title and therefore the underetred old Bartram _ direction and complies*Rh the latest Standards of Tral 9Nvqs •,g maks no Cer.catlorts regdng 2lfarmatan "".1 Nn: 120075 0405H 6/3/13 nB _ Practice b Assert as promulgated by the Flarlda State stn..,s opt w000,,hers,prtdnn.to....tn.,.020203, nh 6 'SEW �5L Board of Professional Survsere aid Nppre Choate of sceeae,ts,fllehte-of-.ay risadl Tina tetrad.. 3.33s--gym.=,-- 517 FG,Pursuant to seater,472_027,Florio 603035y ur•*Wok agm...,M refr.,M..ot1r N/A SC' 1- FAG,'tallies.R!}Ct to dl notes and notations Slosh hereon. em's matters e omen may eII the ceelract.M seardl • Eciirsamas'aS. .-awAr.r.,- N/A N/A TM savvy A prepared and cRVOM for the ale.us.of cam' 12/32/17 1'x)3' 'm.�T..'Y.�-E.:21=P .,, DELO MONK CUNPLE1ED MAP OM:WALLY SIGNED 01e dant.awned hereon,d the.,rwy mop,d rpst of tlE Op1es Mereof . not Florida.IMaut cum'. 3400 re and pe 1114 27 RENSMH N/A the aYpind rdrd bed of a Fllicensed entree and 11fIF17-OOJ l 0 THOMAS P.HUGHES,P.L.O. m2ppr. , STATE OF FLORIDA LICENSE NUMBER LS 1507 OMaN eve:mY ClEO®.r:0.0 SHEET 1 aE t -i.a,V.i;4., City of Atlantic Beach APPLICATION NUMBER rs t ' ,1 Building Department (To be assigned by the Building Department.) 800 Seminole Road y Es t - �9 -r)„0 �� Atlantic Beach, Florida 32233-5445 C. 1 Phone(904)247-5826 Fax(903(-95444)5247-5845 4)247-5845 Clx! ` Building Permit Application /8/17 z � ►= OFFICE0 GOR Y/8/17 City of Atlantic Beach _.,;,, 800 Seminole Road,Atlantic Beach,FL 32233 1 (A Phone:(904)247-5826 Fax:(904)247-5845 gg�� � �L 5 4� - OoDei Job Address: T�� �%/<.�.1�:c I�t �z ��. i� 1_01 l Permit Number: Legal Description A1-1004 - c 3« c 0,,,AX/ I CL. w j 36 RE# 164 So 5 - iLLIS Valuation of Work(Replacement Cost)$ goo,0 C Heated/Cooled SF S,3-7 4 Non-Heated/Cooled 1i 5 2 • Class of Work(Circle one): ID Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s) (Circle one): Commercialsid . I • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: •)C,.,) cc •- k--G •-- Florida Product Approval# for multiple products use product approval form Property Owner Information _ Name: 09- 1kni A o c 0e_ k 0p�N }Address: ( 4 C(o o �lSiitv, \ D ;v e City ,`(4,,A,r,/(.. State %34_ Zip 12 Z '47 Phone E-Mail l Co e.i L. AO c cc k Ai L . i 0.--r< Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: :..r;)1. ."u 1tr=..t-1/4-Z k) Lt<. Qualifying Agent: Address I ti 2- 3-k. 5 k Sy.►-@ 4 City /.;z PwAc a'-c s- State Zip 3z Z Q.4 Office Phone itD<-1 - 2 5 `( - C -3 o't Job Site/Contact Number State Certification/Registration# CGL, 5/9.0 IS? E-Mail Iaoke os;ac zLop, „1. cc, -- Architect Name& Phone# (JG y J r c i w — U y - 7/ b —& 3 3,5- Engineer's ,Engineer's Name& Phone# i_e , F yZi I Pie c(2.1615 ._ 2 9 u - F' , 'SZ a J Workers Compensation �� 90 71 Exe t/Insurer/Lease E ploy /Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ANA ORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. _ r ".„.., , ,..,...„;„,, ,,,,,_,,: „.„ z 5. R = I r, (Signature of Owner or Agent) / (Signature of Contractor) i '-°,+,;4.».;t chi I (including contractor) �2 igI-d and sworn to(or affirmed) before me this e day of Signed and sworn to(or affirmed)before me this, da .: Q C) z - 1 W,-A. v� ,by Jod,ena. A-at(�oG� JQIl,�[Q .1018by i �C O i o r++ 1 5 �/ V E /Wi 3 (Signature of t ry) (Signature o otary) = _� °(.11112/11 cc� � o '6 ' rsonally Known OR Personally Known OR r� -• z :>: •!-<<• • •duced Identification [ ]Produced Identification 'r?'v•;;;;,'• •f Identification: 2_,V)1-- ,„,,, Type of Identification: CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST /CORRECTIONS TO PLAN REVIEW COMMENTS Date ilz f/( Revision to Issued Permit Corrections to Comments v Permit#RCS( g OOd Project Address 76€ A4 t. . A- 14- -z Contractor/Contact Name ()S `i- 0 SS c Phone T` 5 ' —6 7 a at Email )7(ct 1G S 5 i tacit Description of Proposed Revision/Corrections: Permit Fee Due$ 50,06 !ADD('b y ;�Ic� �� --11"4,1 4- 'v- lcryo� •Ge" A-r k5 Additional Increase in Building Value $ Additional S.F. By signing below,I Oct It v. 1.4 c k vti affirm the Revision is inclusive of the proposed changes. (printed name) Z 2. ( Signa a of Contrac r/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Th S ed PS a -a- %n Ic /4 D ci f lee ciya / 0 not ists r Department Review Required: - Building ��lanning & Zoni4 Reviewed By Tree Administrator Public Works Public Utilities - 0.1 Public Safety Date Fire Services �s� ►"� CITY OF ATLANTIC BEACH .- A Jlir1p 800 Seminole Road 7.5 i Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date ((3 (4) Revision to Issued Permit Corrections to Comments Permit# 2E 5I E -voo Project Address 176 q A4_(.,..".‘,:,_ :-. .`cc,-. '3r Contractor/Contact Name 55 --5,c cp S S Phone 10,-L--i 5-t;.— C 3 d,N Email AK/cA c_3 s J e✓eco p 0-.,..,. k . r.,,.-, Description of Proposed Revision Corrections: Permit Fee Due$ SO, O ci. 1✓lkti /h/C Cc�Gc^ �tV^ (Skrt.G4../tt 1 i re., f� G I-0A., f'<</L,-� l t-t` . `Y 0._;- 4-F () S p e.tit_ C.--,1 / f�2G�K �,". S 4-k Ckti-041 C ?(a A. C.I- A�r ..-4......,...... t fff Additional Increase in Building Value$ Additional S.F. By signing below,I D 6w1_ Le` I- 4n..-4.. affirm the Revision is inclusive of the proposed changes. (printed name) A //I 6' ignature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved )( Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: -- :uildi /lid,- 'lannin• & Zoning Reviewed By Tree Administrator u lic Worcs s; p LA tJ biic [nosr 2- 6 -c O/� Public Safety I LA-/ Date Fire Services r" 1r .:\i`!AIL'- \ , CITY OF ATLANTIC BEACH I4 w, f r, `, 800 SEMINOLE ROAD -�� OFFICE COPY ATLANTIC BEACH, FL 32233 (904) 247-5800 � Jlil9'. BUILDING REVIEW COMMENTS Date: 1/26/2018 Permit#: RES18-0009 Site Address: 1769 ATLANTIC BEACH DR Review Status: RE#: 169505 1475 Applicant: OSSI CONTRACTING LLC Property Owner: ADCOCK BRIAN 1 Email: OSS188@HOTMAIL.COM Email:jodeneadcock@aol.com Phone: 9046103195 Phone: THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: -..,------- 1. �1. Submit 2 copies of the manufacturer's installation instructions for the metal roof system to be installed on this home. 2. Submit Florida Product Approval numbers and information on the balcony water proofing system to include the manufacturer's installation instruction. 2 copies. 3. R401.3 Energy Performance Level (EPL) Display Card documents are required to be in the Energy Calculation information package, 2 copies filled out by the builder. 4. An extra copy of page 1 of 7 of the FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING INSTRUCTION, FORM R405-2014. This page has to be filed with the State. Mike Jones Building Inspector/Plans Examiner (j7-eL.f-S/-gal j- City of Atlantic Beach !h O 800 Seminole Road Atlantic Beach, FL 32233 904.247.5844 Email:mjones@coab.us CrmA ;ltd !R'tvieli Comn,an --S' 1 -a6- 2o/ P- pn% /17 Building Resubmittal Notes: t . r All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. OFFICE. COPY • DO NOT WTEApplica. e Co.es: 2010 FL IRIDA BUILDING CODE��® OFFICE ILSE ONLY ReVieyv Result (circle oncl• Approved Disapproved Approved-w/ Conditions .Review Tnitials/Date: Lz7y../8- Deyeiopment Size i labitable Space 3 3 7 s Non-habitable 15'ZZ s npervious area [isceiianeous Inforxma.tion �cupancy Group - 3 pe of Construction V 6 tuber of Stories 2 ling District A 6 G K. Occupancy Load Sprinklers Required d Zone ?c Inions/Comments: • 01..i-v rjr, City of Atlantic Beach APPLICATION NUMBER (--- _..., Building Department '- (To be assigned by the Building Department.) 800 Seminole Road LS IS — coo s� Atlantic Beach, Florida 32233-5445 JAN ` U Phone(904)247-5826 Fax(904)247-5845 ":to;3 j E-mail: building-dept@coab.us Date routed: t L1 I t( ' City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: i'l W GI \&r L_ Lv1 o Department review required Yes No rl (Bilding i Applicant: V,S`�\ Lor' (GtC;-k,JZ(,� ,Planning &Zon g�� ,.J Tree Admiril ff—t& Project: 1\t- ) S‘l�(�\p_..4�('+1�1 \(i opm___ Ccallir.,_ orks-`. �J C Public Utilities Public Safety Fire Services Review fee $ Dept Signature x( UC CL Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By �1 c Florida Dept. of Environmental Protection \.1 .1 Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: I Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING -/ PLANNING &ZONING Reviewed by: / '' Date:#_e_____ TREE ADMIN. Second Review: Approved as revised. ['Denied. ['Not applicable ■U: ORKg i Comments: • BLIC UTILITIES /—/ Z —I PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. I 'Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Doo#2018woars[,vrc o^ Number Pages:1 Recorded 02/14/2018 09:52 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY )TICE OF COMMENCEMENT RECORDING $10.00 State of flood Tax Folio No. County of 10 To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in t is NOTICE OF COMMEN EMENT. Legal Description of property bein improved: D 3 +1A14) t (C A, p 6 o v,f am vN"T R y C( v U, 2 G.,,;, -c / f -b Address of property being improved: f 7 6,9 41-t4-A) t era-ei D r t v E i ,4-4/42,A General description of improvements: k, Res:6114.•1 /C',°r rpm e 12,7ir Owner: _, - -(71•c-l— r ,N C 1L Address: ( 7 S I 5�c�Qc [S pe; v-c A-$I L 323_ Owner's interest in site of the improvement: Cit.,iv ti Fee Simple Titleholder(if other than owner): Name: Contractor: 0 5 7 y— v� f�j/1 5 L / ( 1 Address: $ E ( 7 ,3RD 7 i' / N,G� 1)A 2��, (� L 32-2-0 6 „ Telephone No.: i 9 Fax No: P � JY- C�. iv 3 � Surety (if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement (the expiration date is one (1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER / Signed: �, -� Dater//y/ /8- 2if�! ELLEN R.THIGPEN Before me "is 11{ day of c—(iOndx. " — in the County of Isssiii uval,State MY COMMISSION#GG 144796 Of Florida,has personally appeared p N e �t:pt •.'� ��.ro= EXPIRES:October 23,2021 Notary Public at Large,State of Florida,County of Duval. .EPEE:°•' Bonded mruNotaryPublic Undervrtlters My commission expires: (1/ 2.!/, 2_ Personally Known: I _ or X1 ,.► : Produced• Identification: P. A 1 / ,i ' i1.71'. , glow City of Atlantic Beach �'' PUBLIC UTILITIES DEPARTMENT ,, 1200 Sandpiper Lane Atlantic Beach, FL 32233 �% (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date /—f Z / y Project Address X76 9 i4 /, ?J -z2 D7, Number of Units ( Commercial Residential V Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) e/ New Irrigation Meter Upgrade Existing Meter from to (size) 3 New Reclaim Water Meter `'� Size /� New Connection to City Sewer I-- __, Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application# lE5 I - 000`7 Water System Development Charge $ /, /`I °, CO Sewer System Development Charge $ O SZ) . ai Water Meter Only $ 1 8 o-a Reclaim Meter Only $ ( cso Water Meter Tap $ Sewer Tap $ Cross Connection $ D Other $ TOTAL $ ea /0 , Go (Notes) APPROVED Kayle Moore, P.E. 5L, Date C6 11 Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED F CEiVE r rCITY OF ATLANTIC BEACH j. FEB 012018 800 Seminole Road -^" � Atlantic Beach,Florida 32233 );il9`" REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date i (r2)1 ikt Revision to Issued Permit Corrections to Comments Permit# 2E 51 g - [>oac\ Project Address 1'76 I A ('v_ c._ C-' •`,,_c... i)r Contractor/Contact Name d 55 c c_ S's Phone qo"{--L 5--(_— c 3 d 0\ Email UCKdrAi, e p s 5 : A e✓eco P « 4 • C .-) Description of Proposed Revision Corrections: ) Permit Fee Due $ � ie 1Jfkh A/C Ce."Gol. oto (SCrt.-G4v/?a I 1 '• c (-oA., 6',-14.+„._. 1 t-c c 7 F( ,7. 5 n G.,.t Era 7(/ll.4.K S a.cc4,i"•••tP ��a`` .� c.�t.- o. , e�...-e.........-e...... t l Additional Increase in Building Value $ Additional S.F. By signing below,I D 4..— Le 4._ 1- in...A.4A affirm the Revision is inclusive of the proposed changes. l' --- (printed name) / //5 A er ignature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department f/- Revision/Plan Revision/Plan Review Comments Department Review Required: / 'lannii Zoning Reviewed By Tree Administrator •u is Wor c S i TP LA 10 2_ i (7- ( k otic i i ie Public Safety i JLA-/3 Date Fire Servicesi,_,/4___.-c.—., S1,:U‘�;\ City of Atlantic Beach APPLICATION NUMBER is ', Building Department (To be assigned by the Building Department.) ' . , 800 Seminole Road RS �( _ DDC1 Atlantic Beach, Florida 32233-5445 �J ,� Vf Phone(904)247-5826 • Fax(904)247-5845 JAN 1 0 2101) Q� 01119? E-mail: building-dept@coab.us Date routed: k I LL I i U City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: r k ('Gi Ar1-1 aNfi;l_ Ult.v\0(, De artment review required Yes No (—Building—) Applicant: D.SS1 C-6fY\ (C-l(.t/1( Plan nin g&Zon �.! \^ Tree Admmis rator Project: ltt,w S ft 2 __ -cn1IA V`0'� — 1.04,E ...2) ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date . of Permit Verified By � ,., ac, Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING s PLANNING &ZONING Reviewed by Date: &//.�/, TREE ADMIN. Second Review: Approved as revised. ❑Denied. fNot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES / ,p PUBLIC SAFETY Reviewed by�lv�G� """ tei Date:/-0217f FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 8 t•C Z"`" -.tfr,,,, !VET) ( JAN 2 CITY OF ATLANTIC BEACH 2018 ,1 800 Seminole Road By: Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date r Revision to Issued Permit Corrections to Comments ,/Permit# ' \E.,s 15 -Ccocit Project Address 1 7 (o 1 / AJ ► i 1 flL ) 2 /e / ,91 A _ L1L / / Z233 Contractor/Contact Name (.�S 3; G ti!1/YA�fv p, LL Z � air; 1 Phone Q J y —L / v ,3 / 9S Email � 6) 3 6 Si 0/.;v E l aeo n X L-r>/'7 Description of Propsed Revision/Corrections: Permit(itFee Due $ 6 l�'C w✓i�L __ (/ C Gill met-A; Additional Increase in Build'• Value $ 0 Additional S.F. C.) By signing below,I qndi L . ;affirm the Revision is inclusive of the proposed changes. (printed name) / . e 1// 1// - Signature o ! . tractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments r Department Review Required: VBuilding _ w i7d,6 _ Planning & Zoning 'eviewed :T Tree a•mu nistrator •ublic Work5_, / 'us is 1 I I les Public Safety Date" Fire Services YI 1.-U,/ ry� ., P', Al ii 11 REVOCABLE ENCROACHMENT PERMIT REVOCABLE ENCROACHMENT PERMIT by the City of Atlantic Beach,Florida,a municipal corporation organized and ee. fistingder the laws f the State of Florida,hereinafter referred to as"CITY"and I l V A- 4-'4 z t34c1 04:4V-(.. of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. This work is generally described as Pti-y.e.g ce,1 ✓C w ,-1„/ . Any facility maintained, repaired, erected, and/or installed in the exercise of the pfivilege granted remains subject to relocation or removal on thirty (30)days' notice by CITY to USER, said notice to USER shall be giv n by certified mail, return receipt requested,to the following address t �g ,�.�-1111... - , J1 A QO;✓� . 9 6-1 8s( • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter %t 3 2z3 upon the above described property of the CITY,the USER shall replace at the USER's sole expense,any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks.” • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of public right-of-ways and other public 1..d. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER V.7 any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed the USER. Date (77/e- _ Property Ow gent(signed in presence of Notary Public) STATE O 7 ORIDA,COUNTY OF DUVAL The foreg: g instrument was acknowledged this I / day of Q n , ,20 / 8..). by ---\/'rL c7 - ,who personally appeared before me and ed name of Signer) acknoit ed that :he :'gned the instrument voluntarily for the purpose expressed in it. 41 irAIIII _� Signature of Notary � a o' • i diApproved I Public Works Department: Personally Known �. Produced Identification(Type) ' /-,?4"--40 TONI GINDLESPERGER Scott i iams, ub lc rks Ulrecto� r `� /Q •r . MY COMMISSION if FF 924951 5 =9c.,��.a= EXPIRES:October 6,2019 :14. OS Bonded Thru Notary Public Underwriters t ..ICEIVE CITY OF ATLANTIC BEACH j`' FEB 2018800 Seminole Road ' Atlantic Beach,Florida 32233 \o;3)>r REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date l ( l/t Revision to Issued Permit Corrections to Comments Permit# 21`C 5l - C,00c{ Project Address 176 Q A.-1 v - C,.«c-. -6f' Contractor/Contact Name c'55 : —5�cc-- cp SS 4: Phone 10%1.—2_, 5 e—t__ C o Email AKr!iAtik 6 s5 ,. je✓moo()w. A . c�,., Description of Proposed Revision Corrections: Permit Fee Due $ te �/K� /�/c �vGo. �(V,,� (Sl�c�c4..- i i f'�• c I-a^5 / i<—t, r� 1,- ?( Cmc s p i, 6,—.1 7 vi-u, Lw s.t�(cti .e ,/ ?revA..... C- 1— c,,(9rrv✓e... t Additional Increase in Building Value $ Additional S.F. By signing below,I D 6a--1- Le 4._ H tA.-e-4.4i1, affirm the Revision is inclusive of the proposed changes. er. y..., 1..0...,;_______ (printed name) //5 /A Zf ignature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department i. Revision/Plan Review Comments Department Review Required: N arming&Zoning Re vie vie �d Bye ' a Tree Administrator St T6 PLtd ,,D c----Pit lic �i ie 1.4;1...-•/fp Public Safety 17� �L � Date Fire Services (--- SITE PLAN LOT 36 AS SHOWN ON PLAT OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 87, PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FL. GRAPHIC SCALE >D 0 19 p (S rN FEET , OFFICE S ti P 1 inch = 90 ft \ •\ CFI \ \ \\\ `Q %� \ ii:,st .,...,-:. .4...,,s,..---,. . VAV. \**s, . * ••• : . ;ms \ \ w 4� 4sp ' c. Ir \ Y mor nj�\ • •.' 2 '� \ .'1::: 'a�.`�, SILT FENCE \ \ 17051 K' � ) 6 \\ \ �; �h1 . fay �4 9 0: .. \\ 1.... 620 ->or' \..._,,,,,,\,.. Mi_*a Wv o7r 92700. 10 \l \. \ rt 3311136.11=6 \1 c\\ 1.MAMMA ANE BAM MINE 4000443E 0i ATLANTIC*AOI OW AS BAC 612,113RE \ \ SWAGS ELEVATIONS WW1 law A*SA*D MINA.,a. \ 1 THE LOWS 900 Law V Ella ROM OW Y AS OEPOTEC 01 TE ROOD.590 0 NATE IMP \ ((FLAW ONHS STE PLAN Mit NAM 11674 F CS PAW 4043 OWL 54270 I.1. r 1 ID,111414 00 IDE 55045 a \ 14010571027 NO®1tA11016 01 11*STE PIAN AM VNO MILY N DATA IC MINFENSOE O THE M OATS Cr 140 ME ALMA 11st WT NW 5 SUNECLIENT 1160045 MIEN 116 DAN 1141 Si WPM=SAO 11OALAI WSW 63.611 R NIA TO T0*.rr E . S 11.030 RAM SNIA 0 P1 REPOMC .0130616 RIM IOW A 1546 WAS MOOT®NE166 A*RAND a Ww 1sO L DENOTES PROPOSED PAVERS n N0 10000010 110001.106 Q IITE1T6•NO 11•661613113 once THAI 71I00 910,1 WE LOWED Willi TE PCQE 6 h.WE RAM. �-�;7 6 AlO1a1S,OLLET1O S NOres r3 NErt AuniON2SO ST M MY w NCN.Tn A006 TO T*MAP Ata/w Ivan 6 naI�TED SWIG SINEWl 'J DENOTES PROPOSED CONCRETE KMOS�ism 10 P 6 PREM. AT A SCENE 61'110'n SIN /1131.EENnEe YAa PATES10mNClm AS EXTENDING INTO TE ulna 1166166.EES WV 1010527 acoem At E DENOTES CHEMICAL TCILET N OT 0.111.02161. A 1.o D,Mo10 547127NE BUFFETS AE109 10 50214 WTMu4 n 4coAmc,Nn 3101 *. 01) DENOTES FUTURE 4' TREE IMPERVIOUS COVERAGE 10 11.44113 ME N FEET AAO MOW PANTS TaEOF. *I WOWS S.it IDT S.R a u 116 oEENISS CO WENN OF Nn 363LAOS AS 4100 oEsa�.71S SNor A IS1taCAtE 6 ME.MEM , 413 Sc Ft 0.704 36 Ft In.3, 12 Ta STE RAN NAM NOT NW=m OE40EA7C n OEFx Mm*142716.0TS*5*RNLY SWIM WAS.aniE NA51A1S de.000405 UE 6 ANY MOON.SIA10.V➢aML a IDO L AmD,, UNE TABLE 6W NO�a1 at 01101 01111A10 M t LVdl11 0117*T0Qll01 I NOT TE BATF 11 6 1.54E IEAMSED MAS AMD 616106 A*D0l1CAL MI MAT VALISE N[ 04671011 LOON BUILDING COVERAGE 1A n*cm RAN IS 65*3 1 11406057101 AS P505Om BY TIE CLINT. 1.1(19 1.0.41105 1102 un WOND AID SPRrmR 143 AS DEPICTED NOM ONE POw66tuNN TO 114 NSW PINS ORY UES COWED Sc Ft LOT k PL s .Fm 07)0it Halm.NL M11 A 16 NE STOW 10 M FO ASEN. UIP) 501110E WM NETE la MFA* M TO RAT N AmnSw.17137 TNT WY MEDT T*LOT. 1.713 S.R. 11.7S4 M Ft PPM in.0SATR0ISEWaD "114 SMTY ON ARE BA®a TE a*0061124104 RMS. TEY IL/101.N .WOMA110NN PURPOSES WV NO NE MOT 10 S Nom Will N 014 10E10. N COMM LD2A101I 0540/05 OMENSION 31101 TO TIE SW CONDO INT 6 OW 00615015154 0..a* Tat 6 A WNW IN n1ANDES* MM. a,MLD AM TUN 36 71PO 0E Aro nor l C s�TCOMM COLMITY AM AEU aa/ WOWS= CURVE TABLE 'WWI TIC MOONY N#54 SW.490 HET Ta MOLOWE R.OW REAM 401E TMT MUM(110 e ms.moo:.WJC1)9.41 401*WARES 0 TE 43 15 ONPIE WWI ANC 440 OWN OE6m0 01�WON DELTA 1 OtNME ST..CIIMC mICTD WY VARY N SM. WEB TOO ED56 MA6 N COMM h0.) 4060 MSS HSI.YDEY Ilea PAW OWNICOn 20 A/C PADS 11137 WOW r AMY 1164 ANY MOWN LNE Ala LW NOT EMOg104 MID A MOW. 0500 w 27171]94 141 a2C! ASSENT 41.E TO SLOWS RAPO>Q AAS EL SENSE STE RAI-Nam @2711 0050111(143/111)(410) rams.A*1SEO S1E RAN-L.0A1FD 451*(1/9/54)(005/90) PUPAE=FON OSSI HOMES c*5rR®9o:OSSI HOMES -iars' z.....�- its BARTRAM TRAIL SURVEYING. INC. .,-mudsv - .._ - - .- s LAND 8V2VI<Y008 - PLA - LAND D(VILOP INT CONSULTANTS /l)/ W-a =s�...r...�,. I. A 1601 0 IC>CVI AFL 104 17017 ISD(904 1384-E �J\ =X- m�I' COPYC 2017 ilUIPMVii'ii6.T-- 43074,11014: F.131.11.`146 2EIN � X(N/A) R- ' a- n HEREBY this AiIF7,that surer,graphicallyO y FPBMEnts m.matey l0. ism .MM. out 0 .Bt of abstract or 6/ELEVATION: 7g;,i ,� j1 t4. ult.of Sid army mods uncle-my y,a y r5 ./ 01 le 4504 of TAM and IM.I5M .MM1 . .und .d and Bartram _.� ,e moo Olfaction and compile.with t4.lot..)Standard.o/ Troll Sunw7hg matin no*51115atlons resorting Informal. 1.11 NG: mon 04054 9/3/13 1( Q .. Practice for 9aa)5 aIl promulgated by .Florida Stat. Moen ar of Moen honor,pertaining to easements,dolma (/ ��,� �`��i Boerd of Prof.Or.5*40(ure mai Mops.,00.41 of aamfO..RId11.-ot-May,sad a1.1M.5 walap.. _ y-,-^R_ 9,1-17 P.A.C.:Pummel)to section 472.027.Florida Boundary LM.JEWta,agnan5lt1 re.wt4510 or other n/P0 N/A .t�wA advise to dl nota anO d notation.Neon Mow. nes motif..4NSh may appear M Me 030worth..,01.ar wor . •-BE Sala o asr.p,. N/A N/A t4r 0..1.1.pr.pa.e oma 401141*70 in...dlNo er DA1E 12/22/17 1SCALE •�1g' -.'�'e'.EL7...-SIAM:S7;=.. FIELD 1406(CO6OLE1ED MM ORIGIN .LY SIGNED 005 dl0t maned h55,n MO tth.5rwy map and rNpart of Uns oo1A Mw.of 415 mat 11 hMthwl ih.�arha4lfa and "'ICC'. 40: KNSIO. N/A t1.,nynd raised mai of a Floral,Boomed arena and 1199-17-002 THOMAS P.HUGHES,P.LS. m*ppr' STATE OF FLORIDA LICENSE NUMBER LS 3507 QUEM 9r.ESM 00*Mr:DE0 1444471 1 OF t lv 00 ha IA. 5'/44 o ? P/orl'o4 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Adcock Residence Builder Name: Ossi Homes&Development Street: Lot 36 Atlantic Beach Drive Permit Office: Duval County City,State,Zip: Atlantic Beach ,FL,32233 Permit Number: Owner: Adcock Residence Jurisdiction: 261000 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4024.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 2056.20 ft2 b.Frame-Wood,Exterior R=13.0 1627.90 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 340.56 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2359.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 2359.00 ft2 6. Conditioned floor area above grade(ft2) 3379 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(553.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 793 a. U-Factor: Dbl,U=0.34 271.00 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 456 SHGC: SHGC=0.22 b. U-Factor: Dbl,U=0.54 240.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 27.9 SEER:15.00 b.Central Unit 25.9 SEER:15.00 c. U-Factor: Dbl,U=0.54 42.67 ft2 SHGC: SHGC=0.22 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 27.9 HSPF:8.20 SHGC: b.Electric Heat Pump 25.9 HSPF:8.50 Area Weighted Average Overhang Depth: 13.964 ft. Area Weighted Average SHGC: 0.263 14.Hot water systems a.Propane Tankless Cap:1 gallons 8. Floor Types (2358.0 sqft.) Insulation Area EF:0.900 a.Slab-On-Grade Edge Insulation R=0.0 2162.00 ft2 b. Conservation features b.Floor over Garage R=19.0 175.00 ft2 None c.other(see details) R= 21.00 ft2 15 Credits None Glass/Floor Area: 0.164 Total Proposed Modified Loads: 94.65 PASS Total Baseline Loads: 95.00 I hereby certify that the plans and specifications covered by Review of the plans and OF'CKE ST97-.•..•. this calculation are in compliance with the Florida Energy specifications covered by this O Code. calculation indicates compliance 'y ii„ e ' with the Florida Energy Code. of',�_ O=. PREPARED BY: ___ �i ,f_ , ,._ Before construction is completed •`'' a ' DATE: 11/14/17 / / this buildingwill be inspected for V, C p c7y, a compliance with Section 553.908 `:• *`.. - j."1 * ;•' Florida Statutes. ' I hereby certify that this building, -. d*signed, is compliance !�rCO _ Jy .' with the Florida Energy Code. D WE�: OWNER/AGENT: _ BUILDING OFFICIAL: DATE: , ,. DATE: filv2 - 6 -.90/er - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017 this project requires an envelope leakage test report with envelope leakage no greater than 6.0 ACH50(R402.4.1.2). 11/14/2017 8:14 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 1 of 7 OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: ,AGocv% N)cc Permit # pA S -00 0 9" Project Address: 32z 3 3 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.or�. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # A.EXTERIOR DOORS 1. Swinging ��� T �-rte Z /wLO��� 022-00e ,_ jl, 3 2. Slidingfuyle vie .. w uaik Yclk..) R�-'y g5oo, t 3. Sectional 4. Roll up 5. Automatic 6. Other B.WINDOWS 1. Single hung ? 2.Horizontal slider 3. Casement 4.Double hung 5.Fixed 6.Awning 7.Pass-through 8. Projected 9.Mullion 10.Wind breaker 11. Dual action 12. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL /� 1. Siding i 1�✓v� ACV') ioo 7. 2. Soffits Jac 5z 'rk., , 5� :at )6,6'4") 13�65 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. men Underla u 6/ '� � +� .__. Underlayments 1 ( 7 J'r'"'-7 uv11 b-ty\_ PO°F v�.Y u✓�v (1 Q1v� 52 S t- 3. Roofing fasteners 4. Nonstructural metal roof hulF Coco, - 5i/ C7 :.��� � Ga •Sa c,'„,i) 15131,- lit,)(. t 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10.Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing G-A P i17d-o Y-op ye)//./ 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof I. 17. Other • Category/Subcategory Manufacturer Product Description 1Limitation of Use l State# Local # E. SHUTTERS 1.Accordion • 2. Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F.STRUCTURAL COMPONENTS 1.Wood connector/anchor 2.Truss plates 3.Engineered lumber 4. Railing a . 5. Coolers-freezers 6. Concrete admixtures 7. Material ----- ---- 8. Insulation forms 9. Plastics 10. Deck-roof 11.Wall 12. Sheds 13. Other G.SKYLIGHTS 1. Skylight 2. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # H.NEW EXTERIOR ENVELOPE PRODUCTS 2 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) '51t.Ck 055 ' (Signature) Company Name: rj5$-, Cc,n>.r'ck_CA>/C\ Mailing Address: (a( 2!- 3 of 5 4- ,S u S City: /�(G� h' c/�� L State: r Zip Code: —522-6 Telephone Number: (60* ) 2`j K-G 30 c.. Fax Number: ( ) / Cell Phone Number: (ck ) 2 `� `4 - C 6* E-mail Address: (�( (0.k P gni0(e4-Co2 ,A1-`4j uniast Meta : July 31, 2015 OFFICE COPY Dear Valued Customer, RE: New Permit Application procedures for Jax Beach (Galvalume or Aluminum) The attached engineer's letter titled "FL 16980 Validation of Product Compliance" should be presented with a copy of our Evaluation Report FL#16980.l (for 24GA Galvalume)or Report FL#16980.2 (for Aluminum) when applying for a new permit for I- '''A" Clipless Snaplock (Jax Beach) in either galvalume or aluminum. It will take a bit longer to get these products correctly listed on the State's website. Once again, my apologies for this interruption in your capability to permit these two products. Best Pers egards, Terrance Kapro 2120 SW Poma Drive; Palm City, Florida 34990 0 772-223-4055 Phone 0 772-781-7492 Fax www.sunlastmetal.com 0 sales@sunlastmetal.com meamin T LJ- ,"__ ENERGY STAR Locke Bowden,P.E. July 24,2015 9450 Alysbury Pian Montgomery,AL 36117 FL 16950 Validation of Product Compliance Manufacturer:SunLast Metal 2120 SW Poma Drive Palm City, FL 34990 (772) 223-4055 Product All metal roofing panels listed under FL 16980 These metal roofing panels have testing for Metal Roofing protocol to be compliant with Florida Building Code 2014 5*ed.,for application as referenced under a Product Approval;FL16980. Product is compliant under the 2014 FBC St ed.and currently in process for approval and is compliant with Rule 161G20-3. Products may be permitted and installed which follow the specifications and within the parameters of the evaluation reports listed under FL 16980. R Reg a 49704 /;r No. 49/94 -7x � . 0 STATE OF �•�, . '� (� ••^'r4ORiON /c l3 • r a a u �'-� °;VA L Eyov• } Sunlast Metal Inc FL 1116980.1 EVALUATION REPORT OF SUNLAST METAL Inc. "Jax Beach Series" 1.50" Clipless Snaplock Roof Panel over 15/32" Plywood Metal Roofing Assembly For Florida State Product Approval FL # 16980.1 Florida Building Code 2010 Per Rule 61G20-3 HVHZ Method: 1-D Category: Roofing SubCategory: Metal Roofing Product: "lax Beach Series" Roof Panel Material: Steel Panel Thickness: 24 GA. Panel Width: 15"—19" Panel Seam: Snap-Lock(See Table) Support Type: Wood Deck(15/32"min.) Product Manufacturer: Sunlast Metal Inc. 2120 SW Poma Drive Palm City, FL 34990 Engineer Evaluator. „%% h+`ES F• James F. Biagi P.E. FL#37467 1915 NE 45"'St, Suite#107 i'\4 * Fort Lauderdale, FL 33308 _ \ Validator: = FF 4 s Locke Bowden, P.E., FL#49704 ��= << r 9450 Alysbury Place 'tti, � Montgomery,AL 36117 Contents: Evaluation Report Pages 1-5 Page 1of5 Sunlast Metal Inc FL#16980.1 Manufacturer: Sunlast Metal Inc. Product Name: "Jax Beach Series" 1.50 Clipless Snaplock Product Category: Roofing Product Sub-Category: Metal Roofing Compliance Method: State Product Approval Rule 61G20-3 Panel Description: "Jax Beach Series" 1.50" Clipless Snap-lock Roof Panel mechanically attached to wood deck with screws. Panel Material/Standards: Material: Steel Yield Strength 40 ksi minimum Corrosion Resistance: Material shall comply with Florida Building Code Section 1507.4.3 Panel Dimensions: Thickness: 24 Gauge Min. Width: 19" (Max. net coverage) 15" (Min. Net coverage) Rib Height: 1.5" Support Type: Wood Deck 15/32" min. (Design of support not included in this evaluation) Slope Range: Minimum slope shall be 2:12 or greater in accordance with Manufacturers recommendations and in accordance with FBC section 1507.4.2 Underlayment: Underlayment shall be as per Manufacturers guidelines as required in FBC section 1507.4.5 Fire Classification: Fire Classification is not within the scope of this evaluation. Attachment Components: Roof Panel Fastener: Size: #10 x 1" (3/16"minimum penetration through support) Type: Pancake-Head wood screws Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.1 Seam Adhesive/Sealant Product Name: Bostick 70-05A/Simson ISR 70-05 Type: Silyl modified polymer(SMP) Application Location: Applied continuously on both sides on male leg. (See Table A) Page 2 of 5 Sunlast Metal Inc FL 416980.1 Insulation: Optional: Rigid insulation board, 3" maximum thickness and shall comply with FBC section 1508, materials standards shall comply with table 1508.2.2 Installation: Sunlast Metal Inc. "Jax Beach Series" 1.5" Clipless Snaplock Roof Panel to Wood Deck • Screw Spacing: Refer to Table A (Along the length of the panel and nominally 3" from all ends) Minimum penetration • Rib/Seam Interlock: Snap-lock Seam, (panel ribs shall be fully engaged to form an integral snap- lock • Seam Adhesive: Refer to Table A & Drawing on Page 4 (Apply on one bead on both sides of male leg the full length of the panel) • 3/16" minimum fastener penetration through bottom of support • For panel construction at the end of panel, refer to Manufacturer's instruction and any site specific design Design Uplift Pressure: TABLE A MAXIMUM DESIGN PRESSURES ' Roof Areas Field Perimeters and Corners Maximum Design Pressures -97.25 psf -161 psf Screw Spacing 6" o.c. 3" o.c. Applied continuously on I Applied continuously on Seam Adhesive both sides on male leg. both sides on male leg. *Maximum Design Pressures include 2:1 Safety Factor QUALITY ASSURANCE: The manufacturer has demonstrated compliance of the roof panel products in accordance with the Florida Building Code and Rule 61G20-3 for manufacturing under quality assurance program audited by an approved "Quality Assurance Entity" through KEYSTONE CERTIFICATION, INC. (FBC ID # QUA 1824) Code Compliance: This product described herein has demonstrated compliance with the FBC section 1504.3.2 Evaluation Report Scope: This product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code, as related to Rule 61G20-3. Page 3 of 5 Sunlast Metal Inc FL 416980.1 System Limitations: The required wind loads shall be determined for each project per FBC, 2010. The maximum fastener spacing herein shall not be exceeded. Any rational analysis computation shall be prepared by a qualified design professional and in compliance with FBC 2010. Reference Data: Entity Report No. Standard Year Architectural Testing Inc. (TST 1527) C6413.02-450-18 TAS 125 2003 Architectural Testing Inc. (TST 1527) D4563.01-450-18 TAS 100 1995 PRI Construction Materials Technologies (TST5878) AKZC-001-02-01/05 TAS 110 2000 PRI Construction Materials Technologies (TST5878) AKZC-001-02-01/05 ASTM B 117 2002 Akzo Nobel Coatings, Inc. Lab Form ASTM G 153 INSTALLATION METHOD DRAWINGS TYPICAL ASSEMBLY PROFILE VIEW 15'-19" \ - SEALANT - AliC„SEALANT i\Tm 0/000 DECK TYPICAL ASSEMBLY ISOMETRIC VIEW Page 4 of 5 • Sunlast Metal Inc FL 416980.1 SUNLAST JAx BEACH SERIES 1.5 OPf1ONAL STIFFENING RIOS ADHESIVE ON BOTH SIDES Of SEA1A 0#0000)4111111p 00, it% %000. FASTENERS EVERY 6" IN FIELD ZONE d3 FATtPtics two- r IN CORNER ZONE See page 2&3 for fastener and adhesive sealant specifications (OPTIONAL) Rigid Insulation as per pg. 2 of this report Design Uplift Pressure: TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeters and Corners Maximum Design Pressures 97.25 psf 161 psf Screw Spacing 6" o.c. 3" o.c. Applied continuously on Applied continuously on Seam Adhesive both sides on male leg. both sides on male leg. *Maximum Design Pressures include 2:1 Safety Factor Page 5 of 5 • d 6.6 G�,,,,�m l,.�e./ F2 e 4c, ,, tea{ ho-e-1oac.c. et C• C'. et". FLORIDA ENERGY EFFICIENCY CODE 2-6 tot". OFFICE Cr FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Adcock Residence Builder Name: Ossi Homes 8 Development Street: Lot 36 Atlantic Beach Drive Permit Office: Duval County City,State,Zip: Atlantic Beach , FL, 32233 Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261000 Cond.Floor Area:: 3379 sq.ft. Cond.Volume: 36388 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: CFM(50): C: n: R: ELA: Single or Multi Point Test Data HOUSE PRESSURE FLOW: EqLA: ACH: SLA: ACH(50) * : * For prescriptive projects, tested leakage must be <=7 ACH(50). For performance projects, tested leakage must be <=the ACH(50) shown on Form R405-2014 for this project. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake, makeup air, backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test,shall be turned off:and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing shall be conducted by either • I hereby certify that the above envelope leakage -01.Eindividuals as defined in Section STgTF�. performance results demonstrate compliance 553.993(5)or(7), Florida Statutes or with Florida Energy Code requirements in :'�;'�� °.''`..t accordance with Section R402.4.1.2. individuals licensed as set forth in ; : ins•• ,,, ,,,,, • O Section 489.105(3)(f), (g), or(i) or an rl .a _ 7° fi approved third party. A written report •a of the results of the test shall be signed . .• • �. •• / SIGNATURE: by the third party conducting the test _ and provided to the code official. • CO0'wE J�•' PRINTED NAME: DATE: BUILDING OFFICIAL: DATE: 11/14/2017 8:15 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 OFFICE COPY FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. Lot 36 Atlantic Beach Drive, Atlantic Beach, FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood,Exterior R=19.0 2056.20 ft2 b. Frame-Wood,Exterior R=13.0 1627.90 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 340.56 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=38.0 2359.00 ft2 6. Conditioned floor area(ft2) 3379 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.34 271.00 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Garage 6 793 SHGC: SHGC=0.22 b.Sup: Attic, Ret:Attic,AH:Attic 6 456 b. U-Factor: Dbl,U=0.54 240.00 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.54 42.67 ft2 a.Central Unit 27.9 SEER:15.00 SHGC: SHGC=0.22 b.Central Unit 25.9 SEER:15.00 d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency a.Electric Heat Pump 27.9 HSPF:8.20 Area Weighted Average Overhang Depth: 13.964 ft. b.Electric Heat Pump 25.9 HSPF:8.50 Area Weighted Average SHGC: 0.263 8. Floor Types Insulation Area 14.Hot water systems galns a.Slab-On-Grade Edge Insulation R=0.0 2162.00 ft2 a.Propane Cap:1 EF:0.9 EF:0.9 b.Floor over Garage R=19.0 175.00 ft2 c.other(see details) R= 21.00 ft2 b. Conservation features None 15.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building :;'�TH6STq••. Construction through the above energ saving features which will be installed (or exceeded) 0..�. ; •• in this home before final inspecti• . 0' erwise, a new EPL Display Card will be ompleted .../.0*. ` -*,„'•.'' " , ,,'.. based on installed Code co : ant f-:tures. S/.: '.4 0%moo a - Builder Signature: Date: 'a: 0 Address of New Home: / s. 1I. / i Cit /FL Zi•: ' -' .. W c. C.D. *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/14/2017 8:15 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Adcock Residence Builder Name: Ossi Homes&Development Street: Lot 36 Atlantic Beach Drive Permit Office: Duval County City,State,Zip: Atlantic Beach ,FL,32233 Permit Number: Owner: Adcock Residence Jurisdiction: 261000 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4024.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 2056.20 ft2 b. Frame-Wood,Exterior R=13.0 1627.90 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 340.56 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2359.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 2359.00 ft2 6. Conditioned floor area above grade(ft2) 3379 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(553.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 793 a. U-Factor: Dbl,U=0.34 271.00 ft2 b.Sup: Attic, Ret:Attic,AH:Attic 6 456 SHGC: SHGC=0.22 b. U-Factor: Dbl,U=0.54 240.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 27.9 SEER:15.00 b.Central Unit 25.9 SEER:15.00 c. U-Factor: Dbl,U=0.54 42.67 ft2 SHGC: SHGC=0.22 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 27.9 HSPF:8.20 SHGC: b.Electric Heat Pump 25.9 HSPF:8.50 Area Weighted Average Overhang Depth: 13.964 ft. Area Weighted Average SHGC: 0.263 14.Hot water systems 8. Floor Types (2358.0 sqft.) Insulation Area a.Propane Tankless Cap:1 gallons EF:0.900 a.Slab-On-Grade Edge Insulation R=0.0 2162.00 ft2 b. Conservation features b.Floor over Garage R=19.0 175.00 ft2 None c.other(see details) R= 21.00 ft2 15.Credits None Total Proposed Modified Loads: 94.65 PASS Glass/Floor Area: 0.164 Total Baseline Loads: 95.00 I hereby certify that the plans and specifications covered by Review of the plans and O�gEiIE ST9j '•• this calculation are in compliance with the Flonda Energy specifications covered by thisOff••.• Code. calculation indicates compliance �„ 14',....s. •�+ with the Florida Energy Code. :4 mn, a',..• ',;.t0•: PREPARED BY: 41IF _ ' _ Before construction is completed .• i '' •:...---..:.:;Ii.....,.. DATE: 11/14/17 / / this buildingwill be inspected for ` 04` �.0 ` G Pe 1 0 ,,i. :a e compliance with Section 553.908 *`... ' , ;' Florida Statutes. herebyI certifythat this building,as designed, is in compliance C with the Florida Energy ode. %. COD- w...11.y OWNER/AGENT: 55 BUILDING OFFICIAL: /99- DATE: //5//2- DATE: _ 2--6 ..)o/.6r" - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 6.0 ACH50(R402.4.1.2). 11/14/2017 8:14 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2014 PROJECT Title: Adcock Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3379 Lot# Owner: Adcock Residence Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Ossi Homes&Development Rotate Angle: 0 Street: Lot 36 Atlantic Beach D Permit Office: Duval County Cross Ventilation: No County: Duval Jurisdiction: 261000 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL JACKSONVILLE INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 System 1 1987 21665 2 System 2 1392 14723.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Kitchen Nook 462 4666.2 Yes 0 1 Yes Yes Yes 2 Living 525 6195 No 0 1 Yes Yes Yes 3 Master Bath 197 2324.6 No 0 1 Yes Yes Yes 4 M Toilet 25 252.5 No 0 1 Yes Yes Yes 5 MWIC1 59 595.9 No 0 1 Yes Yes Yes 6 MWIC2 58 585.8 No 0 1 Yes Yes Yes 7 Pantry 63 743.4 No 0 1 Yes Yes Yes 8 Mud 52 613.6 No 0 1 Yes Yes Yes 9 Laundry 73 861.4 No 0 1 Yes Yes Yes 10 Pwdr 29 342.2 No 0 1 Yes Yes Yes 11 Master Bed 417 4211.7 No 2 1 1 Yes Yes Yes 12 M Hall 27 272.7 No 0 1 Yes Yes Yes 13 Bonus Movie 361 3285.1 No 0 1 Yes Yes Yes 14 B2C 50 455 No 0 1 Yes Yes Yes 15 Bed 2 245 2229.5 No 1 1 1 Yes Yes Yes 16 Bath 2 81 737.1 No 0 1 Yes Yes Yes 17 Bath 1 69 627.9 No 0 1 Yes Yes Yes 18 B1C 50 455 No 0 1 Yes Yes Yes 19 Bed 1 238 2165.8 No 1 1 1 Yes Yes Yes 20 OTB Hall 298 4768 No 0 1 Yes Yes Yes 11/14/2017 8:14 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Kitchen_Nook 59.5 ft 0 462 ft2 _ 0 1 0 2 Slab-On-Grade Edge Insulatio Living 23 ft 0 525 ft2 ____ 0 1 0 3 Slab-On-Grade Edge Insulatio Master Bath 26.5 ft 0 197 ft2 _ 0 1 0 4 Slab-On-Grade Edge Insulatio M Toilet 3.5 ft 0 25 ft2 0 1 0 5 Slab-On-Grade Edge Insulatio MWIC1 6.5 ft 0 59 ft2 ____ 0 1 0 6 Slab-On-Grade Edge Insulatio MWIC2 6.5 ft 0 58 ft2 ____ 0 1 0 7 Slab-On-Grade Edge Insulatio Pantry 16.5 ft 0 63 ft2 ____ 0 1 0 8 Slab-On-Grade Edge Insulatio Mud 8.2 ft 0 52 ft2 ____ 0 1 0 9 Slab-On-Grade Edge lnsulatio Laundry 7 ft 0 73 ft2 0 1 0 10SIab-On-Grade Edge Insulatio Pwdr 0.1 ft 0 29 ft2 0 1 0 11SIab-On-Grade Edge Insulatio Master Bed 48 ft 0 417 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio M Hall 0.1 ft 0 27 ft2 ____ 0 1 0 13Raised Floor Bed 2 — _ 10 ft2 19 0 1 0 14Raised Floor Bed 1 ____ __ 11 ft2 19 0 1 0 15Slab-On-Grade Edge lnsulatio OTB Hall 16.5 ft 0 175 ft2 0 1 0 16FIoor over Garage Bonus_Movie ____ ____ 175 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2638 ft2 590 ft2 Medium 0.5 No 0.9 No 0 26.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2359 ft2 N N 11/14/2017 8:14 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Kitchen_Nook 38 Blown 287 ft2 0.1 Wood 2 Under Attic(Vented) Living 38 Blown 24 ft2 0.1 Wood 3 Under Attic(Vented) Master Bath 38 Blown 74 ft2 0.1 Wood 4 Under Attic(Vented) M Toilet 38 Blown 19 ft2 0.1 Wood 5 Under Attic(Vented) MWIC1 38 Blown 46 ft2 0.1 Wood 6 Under Attic(Vented) MWIC2 38 Blown 59 ft2 0.1 Wood 7 Under Attic(Vented) Pantry 38 Blown 37 ft2 0.1 Wood 8 Under Attic(Vented) Master Bed 38 Blown 396 ft2 0.1 Wood 9 Under Attic(Vented) M Hall 38 Blown 25 ft2 0.1 Wood 10 Under Attic(Vented) Bonus_Movie 38 Blown 361 ft2 0.1 Wood 11 Under Attic(Vented) B2C 38 Blown 50 ft2 0.1 Wood 12 Under Attic(Vented) Bed 2 38 Blown 245 ft2 0.1 Wood 13 Under Attic(Vented) Bath 2 38 Blown 81 ft2 0.1 Wood 14 Under Attic(Vented) Bath 1 38 Blown 69 ft2 0.1 Wood 15 Under Attic(Vented) B1C 38 Blown 50 ft2 0.1 Wood 16 Under Attic(Vented) Bed 1 38 Blown 238 ft2 0.1 Wood 17 Under Attic(Vented) OTB Hall 38 Blown 298 ft2 0.1 Wood WALLS Adjacent SCavity Width Height Sheathing Framing Solar Below # Omt__ To WaI Tpace ype R-Value Ft In Ft in Area R-Vaine- Fraction Abgor Grade% 1 NE Exterior Frame-Wood Kitchen_Nook 19 14 0 10 1 141.2 ft2 0 0.25 0.5 0 2 SE Exterior Frame-Wood Kitchen_Nook 19 12 6 10 1 126.3 ft2 0 0.25 0.5 0 3 NW Exterior Frame-Wood Kitchen_Nook 19 33 0 10 1 333.3 ft2 0 0.25 0.5 0 4 NE Exterior Frame-Wood Living 19 23 0 11 10 272.2 ft2 0 0.25 0.5 0 5 NE Exterior Frame-Wood Master Bath 19 13 0 11 10 153.8 ft2 0 0.25 0.5 0 6 SE Exterior Frame-Wood Master Bath 19 13 6 11 10 159.3 ft2 0 0.25 0.5 0 7 SE Exterior Frame-Wood M Toilet 19 3 6 10 1 35.4 ft2 0 0.25 0.5 0 8 SE Exterior Frame-Wood MWIC1 19 6 6 10 1 65.7 ft2 0 0.25 0.5 0 9 SE Exterior Frame-Wood MWIC2 19 6 6 10 1 65.7 ft2 0 0.25 0.5 0 10 NW Exterior Frame-Wood Pantry 19 10 6 11 10 124.3 ft2 0 0.25 0.5 0 11 SE Exterior Frame-Wood Master Bed 19 18 6 10 1 186.5 ft2 0 0.25 0.5 0 12 SW Exterior Frame-Wood Master Bed 19 21 6 10 1 217.2 ft2 0 0.25 0.5 0 13 NW Exterior Frame-Wood Master Bed 19 8 0 10 1 80.7 ft2 0 0.25 0.5 0 14 NE Exterior Frame-Wood Bonus_Movie 13 2 0 9 1 18.2 ft2 0 0.25 0.5 0 15 SE Exterior Frame-Wood Bonus_Movie 13 2 0 9 1 18.2 ft2 0 0.25 0.5 0 16 SW Exterior Frame-Wood Bonus_Movie 13 17 0 9 1 154.7 ft2 0 0.25 0.5 0 17 NW Exterior Frame-Wood Bonus_Movie 13 22 0 9 1 200.2 ft2 0 0.25 0.5 0 18 NW Exterior Frame-Wood B2C 13 5 0 9 1 45.5 ft2 0 0.25 0.5 0 19 NE Exterior Frame-Wood Bed 2 13 13 6 9 1 122.8 ft2 0 0.25 0.5 0 _20 SE Exterior Frame-Wood Bed 2 13 4 0 9 1 36.4 ft2 0 0.25 0.5 0 21 NW Exterior Frame-Wood Bed 2 13 17 6 9 1 159.2 ft2 0 0.25 0.5 0 22 NE Exterior Frame-Wood Bath 2 13 6 0 9 1 54.6 ft2 0 0.25 0.5 0 23 NE Exterior Frame-Wood Bath 1 13 6 0 9 1 54.6 ft2 0 0.25 0.5 0 11/14/2017 8:14 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space # Omt To Wall Type R-Value Ft In Ft In Area R-Val"e Fraction Ahsor Grades% _24 SE Exterior Frame-Wood B1C 13 5 0 9 1 45.5 ft2 0 0.25 0.5 0 _25 SW Exterior Frame-Wood B1C 13 7 0 9 1 63.7 ft2 0 0.25 0.5 0 26 NE Exterior Frame-Wood Bed 1 13 13 6 9 1 122.8 ft2 0 0.25 0.5 0 _27 SE Exterior Frame-Wood Bed 1 13 17 6 9 1 159.2 ft2 0 0.25 0.5 0 _28 NW Exterior Frame-Wood Bed 1 13 4 0 9 1 36.3 ft2 0 0.25 0.5 0 _29 SE Exterior Frame-Wood OTB Hall 13 11 4 16 0 181.3 ft2 0 0.25 0.5 0 _30 SW Exterior Frame-Wood OTB Hall 13 9 8 16 0 154.7 ft2 0 0.25 0.5 0 _31 SW Exterior Frame-Wood OTB Hall 19 5 11 16 0 94.7 ft2 0 0.25 0.5 0 32 NW Garage Frame-Wood OTB Hall 13 8 6 11 10 100.6 ft2 0.2 0.300000 0 _33 SW Garage Frame-Wood Pantry 13 6 10 1 60.5 ft2 0.2 0.300000 0 _34 SW Garage Frame-Wood Laundry 13 7 11 10 82.8 ft2 0.2 0.300000 0 35 SW Garage Frame-Wood Mud 13 8 2 11 10 96.6 ft2 0.2 0.300000 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated Mud None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.34 0.22 36.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 SE 2 Vinyl Low-E Double Yes 0.54 0.32 64.0 ft2 34 ft 0 in 1 ft 0 in None Exterior 5 3 NW 3 Vinyl Low-E Double Yes 0.34 0.22 36.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 NE 4 Vinyl Low-E Double Yes 0.54 0.32 128.0 ft2 34 ft 0 in 1 ft 0 in None Exterior 5 5 SE 6 Vinyl Low-E Double Yes 0.34 0.22 9.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 6 SE 7 Vinyl Low-E Double Yes 0.34 0.22 6.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 7 NW 10 Vinyl Low-E Double Yes 0.34 0.22 12.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 8 SE 11 Vinyl Low-E Double Yes 0.34 0.22 18.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 9 SW 12 Vinyl Low-E Double Yes 0.34 0.22 8.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 10 SW 12 Vinyl Low-E Double Yes 0.34 0.22 18.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 11 SW 16 Vinyl Low-E Double Yes 0.34 0.22 15.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 12 NW 17 Vinyl Low-E Double Yes 0.34 0.22 9.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 13 NE 19 Vinyl Low-E Double Yes 0.34 0.22 12.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 14 NE 19 Vinyl Low-E Double Yes 0.34 0.22 10.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 15 SE 20 Vinyl Low-E Double Yes 0.54 0.22 21.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None 16 NW 21 Vinyl Low-E Double Yes 0.34 0.22 9.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 17 NE 22 Vinyl Low-E Double Yes 0.34 0.22 6.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 18 NE 23 Vinyl Low-E Double Yes 0.34 0.22 6.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 19 NE 26 Vinyl Low-E Double Yes 0.34 0.22 12.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 20 NE 26 Vinyl Low-E Double Yes 0.34 0.22 10.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 21 SE 27 Vinyl Low-E Double Yes 0.34 0.22 9.0 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 22 NW 28 Vinyl Low-E Double Yes 0.54 0.22 21.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None 11/14/2017 8:14 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 23 SE 29 Vinyl Low-E Double Yes 0.34 0.22 4.0 ft2 2 ft 0 in 0 ft 6 in None None 24 SW 30 Vinyl Low-E Double Yes 0.34 0.22 8.0 ft2 2 ft 0 in 0 ft 6 in None None 25 SW 30 Vinyl Low-E Double Yes 0.34 0.22 18.0 ft2 2 ft 0 in 0 ft 6 in None None 26 SW 31 Vinyl Low-E Double Yes 0.54 0.32 48.0 ft2 12 ft 0 in 1 ft 0 in None Exterior 5 GARAGE ✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation _ 1 420 ft2 420 ft2 54 ft 10.1 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000411 3638.8 199.77 375.69 .3892 6 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 27.93 kBtu/hr 1 sys#1 2 Electric Heat Pump Split HSPF:8.5 25.9 kBtu/hr 2 sys#2 COOLING SYSTEM ✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 27.93 kBtu/hr cfm 0.81 1 sys#1 2 Central Unit Split SEER:15 25.9 kBtu/hr cfm 0.79 2 sys#2 HOT WATER SYSTEM ✓ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.9 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply-- --Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 793 ft2 Attic 193 ft2 Default Leakage Garage (Default) (Default) 1 1 2 Attic 6 456 ft= Attic 256 ft2 Default Leakage Attic (Default) (Default) 2 2 11/14/2017 8:14 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2014 TEMPERATURES Programable Thermostat:N Ceiling Fans: Cooling Jan Feb Mar Apr May X Jun X Jul Aug Sep Oct Nov Dec Heating X Jan X Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov XI Dec Venting Jan Feb X Mar X Apr May Jun Jul Aug Sep X Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 11/14/2017 8:14 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 7 of 7 4 wrightsoft Project Summary Date: System 1 By. Jonathan Jacobs Mechanicalcs LLC. 395 Menashe Ct,Longwood,FL 32779 Phone:386-503-0449 Email:MediariCalcs@gmail.com Web:Meder7CalcsLLC.com Project Information For: Adcock Residence,Ossi Homes&Development Lot 36 Mantic Beach Drive,Atlantic Beach,FL 32233 Notes: Desi•n Information Weather: Jacksonville NAS,FL,US Winter Design Conditions Summer Design Conditions Outside db 37 °F Outside db 96 °F Inside db 70 °F Inside db 75 °F Design TD 33 °F Design TD 21 °F Daily range M Relative humidity 50 Moisture difference 46 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23496 Btuh Structure 17377 Btuh Ducts 2677 Btuh Ducts 5327 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cru) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26173 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22704 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/2 Pressure/AVF 50 Pa 4248 ufm Structure 3915 Btuh Ducts 957 Btuh Central vent(0 cfrn) 0 Btuh Heating Cooling (none) Area(ft2) 1988 1988 Equipment latent load 4871 Btuh Volume(ft3) 21673 21673 Air changes/hour 0.50 0.31 Equipment Total Load(Sen+Lat) 27575 Btuh Equiv.AVF(cfnl) 182 112 Req.total capacity at 0.81 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade BRYANT HEATING AND COOLING SYS... Trade BRYANT HEATING AND COOLING SYS... Model 214DNA0360000B0 Cond 214DNA0360000B0 AHRI ref 9662376 Coil FV4CNF003L AHRI ref 9662376 Efficiency 8.2 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 22624 Btuh Heating output 33000 Btuh @ 47°F Latent cooling 5307 Btuh Temperature rise 0 °F Total cooling 27931 Btuh Actual air flow 0 dui Actual air flow 1050 cfrn Air flow factor 0 chrriBtuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point=31 °F Backup:Bryant Input=8 kW, Output=27297 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WI' ghtyd�. 2017-Nov-14 1421:12 ARight-SuteCa Urtiversal 2017 17.029 RS000000 Page 1 ...velopmentWdoock-Lot 36 Atlantic Beach Dr.ru1 Calc=MJ8 Frort Door faces:SW 4 wrightsoft Project Summary Date: System 2 By Jonathan Jacobs Mechanicalcs LLC. 395 Menashe Ct,Longwood,FL 32779 Phone:386-503-0449 Email.Me dianCalcsgmail.00m Web:MechanCalcsLLC.com Project Information For. Adcock Residence,Ossi Homes&Development Lot 36 Atlantic Beach Drive,Atlantic Beach,FL 32233 Notes: Desi•n Information Weather: Jacksonville NAS,FL,US Winter Design Conditions Summer Design Conditions Outside db 37 'F Outside db 96 °F Inside db 70 'F Inside db 75 °F Design TD 33 °F Design TD 21 °F Daily range M Relative humidity 50 % Moisture difference 46 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 15834 Btuh Structure 15357 Btuh Ducts 1928 Btuh Ducts 3766 Btuh Central vent(0 elm) 0 Btuh Central vent(0 dm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17761 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19124 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/2 Pressure/AVF 50 Pa 4248 cfrn Structure 3890 Btuh Ducts 664 Btuh Central vent(0 cfrn) 0 Btuh Heating Cooling (none) Area(ft2) 1392 1392 Equipment latent load 4553 Btuh Volume(ft3) 14734 14734 Air changes/hour 0.65 0.40 Equipment Total Load(Sen+Lat) 23677 Btuh Equiv.AVF((Ain) 160 98 Req.total capacity at 0.79 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade BRYANT HEATING AND COOLING SYS... Trade BRYANT HEATING AND COOLING SYS... Model 214DNA0300000A0 Cond 214DNA0300000A0 AHRI ref 9678775 Coil FV4CNBOO5L AHRI ref 9678775 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 20457 Btuh Heating output 27000 Btuh @ 47°F Latent cooling 5438 Btuh Temperature rise 0 °F Total cooling 25895 Btuh Actual air flow 0 cfni Actual air flow 875 cfm Air flow factor 0 cfmBtuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 Capacity balance point=26°F Backup:Bryant Input=8 kW, Output=27297 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. r htsott 2017-Nov-1414:21.12 w 9 Rigk-sut.o)Unversal 2017 17.029 RS000000 Pae 2 4r-C p' ...velopment\Adood<-Lot 36All articBeach Dcnp Calc=MMJB FronDoor faces.SW g . wrightsoft. Manual S Compliance Report Job: ffi: System 1 By. Jonathan Jacobs Mechanicalcs LLC. 395 Menashe Ct,Longwood,FL 32779 Phore:386-503-0449 Email:MecteriCals@gmail.mm Web:MederiCalcsLLC.com Project Information For. Adcock Residence,Ossi Homes&Development Lot 36 Mantic Beach Drive,Atlantic Beach,FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 95.7°F Sensible gain: 22704 Btuh Entering coil DB: 76.6°F Outdoor design WB: 77.1°F Latent gain: 4871 Btuh Entering coil WB: 63.3°F Indoor design DB: 75.0°F Total gain: 27575 Btuh Indoor RH: 50% Estimated airflow: 1050 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer. Bryant Model: 214DNA0360000B0+FV4CNF003L Actual airflow: 1050 dm Sensible capacity: 24745 Btuh 109%of load Latent capacity: 5536 Btuh 114%of load Total capacity. 30281 Btuh 110%of load SHR: 82% Heating Equipment Design Conditions Outdoor design DB: 36.8°F Heat loss: 27710 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer. Bryant Model: 214DNA0360000B0+FV4CNF003L Actual airflow: 0 cfm Output capacity. 27972 Btuh 101%of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Sec strip Manufacturer. Bryant Model: Actual airflow: 0 dm Output capacity: 8.0 kW 99%of load Temp.rise: 50 °F Meets all requirements of ACCA Manual S. Actik Ad" Wr'iIght'soft 2017-Nov-14 14:21:12 RighFSute®Uriversa12017 17.029 RS000000 Page 1 ._velopmertWdcodk-Lot 36AtlarticBeach Dr.np Calc=MJ8 Frort Door faces:SW Manual S Compliance Report Job: w rightsoft Date: System 2 By: Jonathan Jacobs Mechanicalcs LLC. 395 Menashe Ct,Lorgwood,FL 32779 Were:386-503-0449 Email:MechariCalcs@gmail.com Web:MectenCausLLC.com Project Information For: Adcock Residence,Ossi Homes&Development Lot 36 Atlantic Beach Drive,Atlantic Beach,FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 95.7°F Sensible gain: 19124 Btuh Entering coil DB: 76.2°F Outdoor design WB: 77.1°F Latent gain: 4553 Btuh Entering coil WB: 63.1°F Indoor design DB: 75.0°F Total gain: 23677 Btuh Indoor RH: 50% Estimated airflow: 875 (Aril Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Bryant Model: 214DNA0300000A0+FV4CNB005L Actual airflow: 875 cfm Sensible capacity: 20802 Btuh 109%of load Latent capacity: 5093 Btuh 112%of load Total capacity: 25895 Btuh 109%of load SHR: 80% Heating Equipment Design Conditions Outdoor design DB: 36.8'F Heat loss: 18871 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0'F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Bryant Model: 214DNA0300000A0+FV4CNB005L Actual airflow: 0 dirt Output capacity: 22529 Btuh 119%of load Capacity balance: 26 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Bryant Model: Actual airflow: 0 cfm Output capacity: 8.0 kW 145%of load Temp.rise: 50 °F Meets all requirements of ACCA Manual S. j � q 2017-Nov-1414:21:12 :4661/4 r' wrig tso,` RigFt-Site®Uriversal 2017 17.029 RSU00000 '' .A Page 2 ...velopmenMdoxk-Lot 36AtlarticBeachDcnp Calc=M,18 Frort Door faces.SW Duct System Summa Job: ilk Wr1�1tSQft' �" ry Date: System 1 By. Jonathan Jacobs Mechanicalcs LLC. 395 Menashe Ct,Longwood,FL 32779 Phone:386-503-0449 Email:MedmriCaks@gmail.mm Web:MederiCalcsLLC.com Project Information For. Adcock Residence,Ossi Homes&Development Lot 36 Mantic Beach Drive,Atlantic Beach,FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.18 in H2O 0.23 in H2O Available static pressure 0.32 in H2O 0.27 in H2O Supply/return available pressure 0.180/0.140 in H2O 0.152/0.118 in H2O Lowest friction rate 0.159 in/100ft 0.134 in/100ft Actual air flow 0 cfm 1050 drn Total efective length(TEL) 201 ft Supply Branch Detail Table Design Htg Cig Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (dm) (dm) FR (in) (in) Mad Ln(ft) Ln(ft) Trunk Kitden_Nook c 3567 0 165 0268 7.0 Ox 0 VIFx 34.6 22.0 st1 Killen Nook-A c 3567 0 165 0.409 7.0 Ox 0 VIFx 20.6 16.4 st1 Landry c 167 0 8 0.460 4.0 Ox 0 VIFx 25.5 7.4 st1 Living c 3003 0 139 0.283 7.0 Ox 0 VIFx 26.0 27.5 st2 Living-A c 3003 0 139 0.257 7.0 Ox 0 VIFx 35.1 23.8 st2 M Toilet c 275 0 13 0.207 4.0 Ox 0 VIFx 52.5 20.8 st4 MWlc1 c 326 0 15 0.174 4.0 Ox 0 VIFx 55.8 31.2 st5 MWIC2 c 345 0 16 0.182 4.0 Ox 0 VIFx 52.0 31.3 st5 Master Bath c 1483 0 69 0.182 5.0 Ox 0 VIFx 49.0 34.1 st4 Master Bed c 2831 0 131 0.134 7.0 Ox 0 VIFx 64.6 48.3 st5 Master Bed-A c 2831 0 131 0.140 7.0 Ox 0 VIFx 60.7 47.4 st5 Mud c 247 0 11 0.285 4.0 Ox 0 VIFx 39.5 13.6 st2 Pantry c 1060 0 49 0.380 4.0 Ox 0 VIFx 24.0 15.9 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (dm) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 0 387 0.268 709 10.0 0 x 0 VinlFlx st5 PeakAVF 0 293 0.134 537 10.0 0 x 0 VinlFlx st4 st4 PeakAVF 0 374 0.134 476 12.0 0 x 0 VinIFIx st2 st2 PeakAVF 0 663 0.134 620 14.0 0 x 0 VinlFlx Al1/4 41/11- Wri t501't. 2017-Nov-14 14:age 1 Rigtt SniteO Universal 2017 17.029 RS000000 Page 1 ...velopmentAdcock-Lot 36 Atlantic Beach Dap Calc=MJ8 Fro rt Door faces:SW Return Branch Detail Table Grille Htg ag TEL Design Veloc Diem H x W Stud/Joist Duct Name Size(in) (cfm) (dm) (ft) FR (fpm) (in) (in) Opening(in) Mad Trunk rb3 Ox 0 0 608 73.6 0.161 568 14.0 Ox 0 V1Fx rt1 rb8 Ox 0 0 442 88.3 0.134 563 12.0 Ox 0 V1Fx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diem H x W Duct Name Type (cfm) (dm) FR (fpm) (in) (in) Material Trunk rt1 PeakAVF 0 1050 0.134 467 9.8 18 x 18 RectFbg 4 wrightsoft. 2017-Nov-14 14:21:12g Right-Su1�Uriuersal 2017 17.029 RS000000 Page 2 AC ...velopmentAdoxk-Lot 36AtlarticBeach Dr.n.p Calc=MJ8 Frort Door faces:SW Duct System Summary Job: wrightsoft4 Date: System 2 By. Jonathan Jacobs Mechanicalcs LLC. 395 Menashe Ct,Longwood,FL 32779 Phone:386-503-0449 Email:MedmriCalcs@gmail.00m Web:MedariCalcsLLC.com Project Information For. Adcock Residence,Ossi Homes&Development Lot 36 Atlantic Beach Drive,Atlantic Beach,FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.18 in H2O 0.22 in H2O Available static pressure 0.32 in H2O 028 in H2O Supply/return available pressure 0.133/0.187 in H2O 0.116/0.164 in H2O Lowest friction rate 0.090 in/100ft 0.079 in/100ft Actual air flow 0 cfm 875 dm Total elective length(TEL) 355 ft Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (dm) (dm) FR (in) (in) Mad Ln(ft) Ln(ft) Trunk BIC c 609 0 28 0.091 4.0 Ox 0 VIFx 17.4 110.0 st6 B2C c 299 0 14 0.082 4.0 Ox 0 VIFx 26.6 115.0 st6 Bath 1 c 498 0 23 0.085 4.0 Ox 0 VIFx 21.5 115.0 st6 Bath2 c 516 0 24 0.090 4.0 Oxo VIFx 18.5 110.0 st6 Bed 1 c 3648 0 167 0.094 8.0 Ox 0 VIFx 18.5 105.0 st6 Bed 2 c 3980 0 182 0.087 8.0 Ox 0 VIFx 28.5 105.0 st6 Bons_Nosle c 2490 0 114 0.079 7.0 Ox 0 VIFx 22.4 125.0 st7 Bim_ ie-A c 2490 0 114 0.082 7.0 Ox 0 VIFx 16.8 125.0 st7 OTB Hall c 2296 0 105 0.088 6.0 Ox 0 VIFx 12.9 120.0 st7 OTB Hall-A c 2296 0 105 0.087 6.0 Ox 0 VIFx 13.1 120.0 st7 Supply Trunk Detail Table Trunk Htg ag Design Veloc Diam H x W Duct Name Type (cfrn) (dm) FR (fpm) (in) (in) Material Trunk st3 PeakAVF 0 875 0.079 700 12.0 15 x 12 RectFbg st7 PeakAVF 0 438 0.079 558 12.0 0 x 0 VinIFIx st3 st6 PeakAVF 0 437 0.082 556 12.0 0 x 0 VinIFIx st3 A1/4 l'illi- w`' tSO�L, 2017-Nov-14 14:21:12 fl�l Right-Sute®Uriversal 2017 17.029 RSU00000 Page 3 .-velopmenhAdcodc-Lot 36 Atlantic Beads ant, Cab=NUB Frort Door faces SW Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (din) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Mad Trunk rb5 Ox 0 0 218 85.0 0.193 623 8.0 Ox 0 VIFx rt2 rb3 Ox 0 0 210 61.1 0.268 602 8.0 Ox 0 VIFx rt2 rb4 Ox 0 0 219 115.6 0.142 497 9.0 Ox 0 VIFx rt2 rb1 Ox 0 0 228 207.5 0.079 418 10.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (dm) (cfm) FR (fpm) (in) (in) Material Trunk rt2 PeakAVF 0 875 0.079 442 8.1 15 x 19 RectFbg 'r' wrightsoft Rig lt-Sute®Uriversal 2017 17.029 RS000000 Page2017-Nov-14 14:21:12 4 -..;gip. _.velopmentAdmd-Lot 36 Atlartic Beach Dr.ri.p Calc=MJB Frog Door faces:SW wrightsoft Static Pressure and Friction Rate o : System 1 By. Jonathan Jacobs Mechanicalcs LLC. 395 Menashe Ct,Longwood,FL 32779 Phone:386-503.0449 Email:MechanCaks@gmail.com Web:MedanCaksLLC.com Project Information For. Adcock Residence,Ossi Homes&Development Lot 36 Atlantic Beach Drive,Atlantic Beach,FL 32233 Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0.05 Heat exchanger 0 0 Supply diffusers 0.05 0.05 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.32 027 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 15 16 Measured length of bunk 50 13 Equivalent length of fittings 48 60 Total length 113 88 Total efective length 201 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.159 OK 0.134 OK Return Ducts 0.159 OK 0.134 OK Fitting Equivalent Length Details Supply 4AE=55,11 C=40,11 G=5,11 G=5,11 C=40,11 G=5,11 C=40,1A=35,11 G=5,11 G=5,VelAd�187:Total EL=4B Return 6L=20,6C2=30,8D3�5,11G=5,11G=5,5A 40,VelAd�105:TotalELO wrightsoft20'17-Nov-1414:a2 A1/4 Ad" Right-Stite®Llriversal 2017 17.029 RSLI00000 Page 1 ._vebpmertWdcodk-Lot 36 Atlar8c Beach Drrty Calc=MJ8 Frort Door faces S W Static Pressure and Friction Rate Job: wrightsoft Date: System 2 By: Jonathan Jacobs Mechanicalcs LLC. 395 Menashe Ct,Longwood,FL 32779 Phore:386-503-0449 Email:MechariCalcs@gmail.mm Web:MedmriCalcsLLC.00m Project Information For. Adcock Residence,Ossi Homes&Development Lot 36 Atlantic Beach Drive,Atlantic Beach,FL 32233 Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0.04 Heat exchanger 0 0 Supply diffusers 0.05 0.05 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.32 0.28 Total Effective Length Supply Return (ft) (it) Measured length of run-out 12 9 Measured length of trunk 10 4 Equivalent length of fittings 125 195 Total length 147 208 Total efective length 355 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.090 OK 0.079 OK Return Ducts 0.090 OK 0.079 OK Fitting Equivalent Length Details Supply 4AE=55,11 C=40,11 G=5,11 G=5,11G=5,11 G=5,1D=10:TotalEL=125 Return 6L=20,6C6=115,11G=5,6CB=25,6CA=10,5E1=10,6CA=10:TotalEL=195 AeSk 411" wrighltsOtt2017-Nov-14 14:21:12 Right-SLAM) 201717.029 RS000000 Page 2 ._vebpmerMdoodc-Lot 36Mantic Beech Dr.nq Calc=MJ8 Frort Door faces SW N 4........ First I I laliketflodt 14x8 165 cim 07' oafo r Nenoweeits 10x6 L 69 cfm 14x8 w 8x4 165 cfm 12x6 07•• 139 cfm 12 x 6 4 - 13 cfm PA„ 139 cfmMToilet 04" 8x4 a 15cfrn 010'• MWIC1 x4 014 PIACI r 49 cfm 18x18 Staqg „ 442 cfm 8 x 4 04 Mud 012" III s ctn 8x4 8x4 0.•, -04" 8 cfm11 dm 04" 18x18 MWIC2 Lai, ittilli 4, 4, Pantry 016" T T 12x6 f 131 cfm 010" 18 x 14 Ret Riser 608 chit 18x18 "' 14" 12x6 Molorited 131 cfm G Spit ASHP Bryant 214DNA0360000B0 FV4CNF003L3L Job#: Mechanicalcs LLC. Scale: 1 :94 Performed by Jonathan Jacobs for: Page 1 Adcock Residence 395 Menashe Ct RightSuite&Universal 2017 Lot 36 Atlantic Beach Drive Longwood,FL32 779 17.029 RS000000 Atlantic Beach,FL 32233 Phone:386-503-0449 2017-Nov-14 1421:16 MachaniCaLLC.com MechaniCals©gmail.com k-Ld36AflanicBeactiDr.rup ls Second I , , I 2x4 23 cfin ON, 1 Bath 1 Bed 1 Bath 2 14x8 Bed 2 8x4 14x8 I 182 cfrn 24 ctrn 167 cfm 04" ■ ,E 111108„ 03” ■ lKi SW 8x4 B2C 184 cfm 41 219 dm' J1 12 x 12 . • 28 cfrn 131C_ �„ 012" 218cfn 04„ ea- 09-.CjIII 08„ rI 112x15 12 x 12 19 c 15 228 cfm •m`� 012,. 010" �- 10x6 105cfn 1 12x6 III 06" 114 cfm �„ '■' 10x6 105 cin OS.. DerniejleMe SpitASI-FBryant • 214DNA0300000A0 FV4CNB005L OTB Hall uzi 12x6 114 cfm 07" Li 111.. Job#: Mechanicalcs LLC. Scale:1 :94 Performed by Jonathan Jacobs for: Paget Adcock Residence 395 Menashe Ct Right-Suite®Universal 2017 Lot 36 Atlantic Beach Drive Longwood,FL 32 779 17.029 RS000000 Atlantic Beach,FL 32233 Phone:386-503-0449 2017-Nov-14 1421:16 MechaniCaksLLC.com Me chaniCaks©gmail.com ...k-Lot36A8anic Beach Dr.rup FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Adcock Residence Builder Name: Ossi Homes&Development Street: Lot 36 Atlantic Beach Drive Permit Office: Duval County City,State,Zip: Atlantic Beach . FL, 32233 Permit Number: Owner: Adcock Residence Jurisdiction: 261000 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts. penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/14/2017 8:15 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Lot 36 Atlantic Beach Drive Permit Number: Atlantic Beach , FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. O 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. O R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. ▪ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open, 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems, if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air IeakagelNindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. O R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. O R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost. prevent supplemental heat operation when the heat pump compressor can meet the heating load. • R403.2.2 Sealing(Mandatory)ll ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i), Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test: Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system, including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test: Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system, including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/14/2017 8:15 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal:and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors, provisions for future expansion or other factors which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. - R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/14/2017 8:15 AM EnergyGauge®USA-v5.1- -Section R405.4.1 Compliant Software Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling-only equipment. This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems, supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools, inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15. The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2.Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 11/14/2017 8:15 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3