761 PARADISE LN - PERMIT ,: �t,„
CIT„ Y OF ATLANTIC BEACH
' 800 SEMINOLE ROAD
1510 ATLANTIC BEACH, FL 32233
''
,,....
, i,,011 9%� INSPECTION PHONE LINE 247-5814
RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: RES17-0247
Description: NEW SINGLE FAMILY RESIDENCE
Estimated Value: 320017.75
Issue Date: 12/18/2017
Expiration Date: 6/16/2018
PROPERTY ADDRESS:
Address: 761 PARADISE LN
RE Number: 172376 0185
PROPERTY OWNER:
Name: SPRINGFIELD BUILDERS LLC
Address: 1881 BEACH AVE
ATLANTIC BEACH, FL 32233
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
,
Phone:
Name: SPRINGFIELD BUILDERS LLC
Address: 13846 ATLANTIC BLVD#204 RALPH BUCK DAVIS
JACKSONVILLE, FL 32225
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
Permit Conditions
City of Atlantic Beach
•
Permit Number: RES17-0247 Description: NEW SINGLE FAMILY RESIDENCE
Applied: 11/1/2017 Approved: 11/30/2017 Site Address: 761 PARADISE LN
Issued: 12/18/2017 Finaled: City, State Zip Code: ATLANTIC BEACH, FL 32233
Status: ISSUED Applicant: <NONE>
Parent Permit: Owner: SPRINGFIELD BUILDERS LLC
Parent Project: Contractor: <NONE>
Details:
LIST OF CONDITIONS
SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS
DEPARTMENT CONTACT REMARKS
1 11/3/2017 UNDERGROUND WATER SEWER INFORMATIONAL
UTILITIES
PUBLIC WORKS Kayle Moore
Notes:
Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field
coordination is needed,call 247-5834.
2 11/3/2017 METER BOX SEWER CLEAN OUT INFORMATIONAL
PUBLIC WORKS Kayle Moore
Notes:
Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible.
3 11/3/2017 RT1 SEWER CLEANOUT INFORMATIONAL
PUBLIC WORKS Kayle Moore
Notes:
A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to
grade and visible.
4 11/3/2017 DRIVEWAY APRON INFORMATIONAL
PUBLIC WORKS Scott Williams
Notes:
All concrete driveway aprons must be 5"thick,4000 psi,with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are
not allowed in the right-of-way. (Commercial driveways-6"thick).
5 11/3/2017 EROSION CONTROL INSTALLATION INFORMATIONAL
PUBLIC WORKS Scott Williams
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(247-
5814)to request an Erosion and Sediment Control Inspection prior to start of construction.
Printed: Monday, 18 December, 2017 1 of 2 •
Permit Conditions
7:73 City of Atlantic Beach
4.01;: ' l'..
6 11/3/2017 ON SITE RUNOFF INFORMATIONAL
PUBLIC WORKS Scott Williams
Notes:
All runoff must remain on-site during construction.
7 11/3/2017 ROLL OFF CONTAINER INFORMATIONAL
PUBLIC WORKS Scott Williams
Notes:
I Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapell's,Inc., Republic Services). Container cannot
be placed on City right-of-way.
8 11/3/2017 RIGHT OF WAY RESTORATION INFORMATIONAL
PUBLIC WORKS Scott Williams
Notes:
Full right-of-way restoration,including sod,is required.
9 11/3/2017 RUNOFF INFORMATIONAL
PUBLIC WORKS Scott Williams
Notes:
All runoff must remain on-site. Cannot raise lot elevation.
10 11/3/2017 MAXIMUM DRIVEWAY INFORMATIONAL
PUBLIC WORKS Scott Williams
Notes:
Maximum driveway width within the City right-of-way is 20'.
Printed: Monday, 18 December, 2017 2 of 2 �p
S�-Lvf. City of Atlantic Beach APPLICATION NUMBER
(To Building Department (To be assigned by the Building Department.)
s 800 Seminole Road -� r U ZC1
-0 Atlantic Beach, Florida 32233-5445 h\ h S 1 7 - T /
Phone (904)247-5826 • Fax(904)247-5845 7
to;iita E-mail: building-dept@coab.us Date routed: 1 ( l /
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 7 (i Ri— \L tsc Li3E- _ Department review required Yes No
( uiIding
Applicant: SP 3C��(�_LQ �� u ( t„!J E--i,--,� tanning &Zoriin�
-Wee-Ad ministrate
Cm N-- Pull it c�Norks-�
Project: G-iAD 1 j\)( t E- (-- A M t L. r-~
�' use!
L -+ ZP") public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. XIDenied. ❑Not applicable
(Circle one.) Comments:
BUILDING /,
PLANNING &ZONING Reviewed by: /71'n Date: �/`4 i
TREE ADMIN. Second Review: ['Approved as revised. nied.
❑ pp ❑ ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: Approved as revised. ['Denied. ['Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
CITY OF ATLANTIC BEACH
__ �5� 800 SEMINOLE ROAD
�j r ATLANTIC BEACH,FL 32233
, �� OFFICE COPY (904)247-5800
\Jii19r
BUILDING DEPARTMENT REVIEW COMMENTS
Date: 11.9.2017
Permit#: RES17-0247 Applicant: Springfield Builders, LLC
Site Address: 761 Paradise Lane Site Address: JAX
Review: 1 _ Phone: 404.626.0245
RE#: 172376-0185 Email: Ralph.buck.davisna,gmail.com—
Homeowner: Same.
CORRECTION COMMENTS: These are plan review comments from 1 of 4 departments
reviewing this permit application.
1. The energy calculations submitted are missing the correct manual S
compliance reports. Please correct and resubmit.
2. Please submit the Product approval number for the roof underlayment.
3. Provide a site plan with the proposed minimum finish floor elevation written
on the site plan in the middle of the largest first floor room. Initial and date
ext to the written proposed elevation. 2 copies.
K-rc // /Cf /7• _.Poi?
Mike Jones mT
Building Inspector/Plan Reviewer
City Of Atlantic Beach
800 Seminole Road
Atlantic Beach, FL 32233-5445
Ofc (904) 247-5844
Fax (904) 247-5845
&net ileCi Revise 4v co m m Prk /1 //--- 9- 17 r'y`'1
1
,
t1'��� CITY OF ATLANTIC BEACH
rj� ►. ��
tt\ OFFICE COPY 800 Seminole Road
.--- •J Atlantic Beach,Florida 32233
r:':::,' , .';r,;, - Telephone(904)247-5800
FAX(904)247-5845
'-71-J,3lS.)r
REVISION REQUEST SHEET OR
CORRECTIONS TO REVIEW COMMENT
Date: ii-11-/ -/7 Received by: Resubmitted:
Permit Number: RE5/7 -OZY7 r
Original Plans Examine s Project Name: ru��cc (�c.s•`a<it&.
Project Address:-7L t aro,Ji (,o,.,,`
Contractor: .7.7../1 3,.,�•*S Lt.. Contact Name: Ti ac.1 '/`,tn'7
C o • : Ion` : 'f (0 2 4.OZ-yr Contact e-mail: rd(1.1-, 6(.c1..das.,./sq gn4..1 t
•evision 'Plan Check/Permit Fee(s)Due: $ (
Description of Proposed Revision to Existing Permit:, :eVI5sbi {per CUMMtn4–s NOV 1 4 2017
Additional Increase in Building Value: $ Additional S.F. '
Site Plan Revised: Public W/U Approval:
Bysignin_ :• .w.I
sgn _ (print name) �\-•'2,>`L-D,.a _- _ affirm that the above revision
is inclus' a of e proposes ;ages.
dir
Signature of Contractor/ ,gent(Contractor must sign if increase in valuation) Date
•'—_A— Office Use Only
Date: (l 2.2' (1 Approved: Rejected: ( " Notified by:—__ -–
Plan Review Comments:
/no/'l tea / `I S" 4'u rm 4 s )1, )! ,r► c owe 71-
_ _
....
Department
1-
Department review required Yes No yy�
�laTildinA� _� — ---1
arming 8 Zonin
ree rns rator Plans Examiner
Ic ors __ ii- ,22-r-2
•
Date Created 4113/16 Rev.3
Fire Services
UV L, -1
i CITY OF ATLANTIC BEACH
800 Seminole Road
- , \SJ
NOV 1 7 2017 iiI;l � Atlantic Beach,Florida 32233
J lr° '. 9 "
"• vti T y Telephone(904)247-5800
ljliP FAX(904)247-5845
REVISION REQUEST SHEET OR OFFICE COPY
CORRECTIONS TO REVIEW COMMENT
Date: //-/7-/"1 Received by: Resubmitted:
Permit Number: e- SIS -Da --(')-- �
Original Plans Examiner: 1 '\ . 1:n,4.s Project Name: .f JhLrA_ 14t;;ckt1‘t.
Project Address: 7L ( 7Nral;y, Ca-‘.-
Contractor: Sr: •cls.13••.%k r% trc.t Contact Name: r .,,� I� any
Contact Phone'4f 44, o2.L1T Co -- -- • . rbyA,t-,.,.1, Aaa s ocv...-A. cosh
(Revisio'Plan Check/Permit Fee(s)Due: $ SO_ DU
Description of Proposed Revision to Existing Permit: 1
-- - r1 1._‘,04tnery� cock ILL C VS,
Additional Increase in Building Value: $ Additional S.F. '
Site Plan Revised: �Pub�lic W/U Approval:
By signi._ bel tw.I(print name)___1L-o\ ���y e_ t..JG , affirm that the above revision
is incl lye o'the prop ges.
l /1-17-17
Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date
Office Use Only
Date: / I — 2 2' n Approved: x Rejected: Notified by: _--
Plan Review Comments:
• • •• * ent review required Yes
Ill).-
Buildin. l/'
Planning&Zoning
Tree Administrator — Plans Examiner
Public Works
— /1.22-/7
Public Utilities _
Public Safety
Fire Services
Date Crated 4/I3/16 Rea.)
ri.:��ir City of Atlantic Beach APPLICATION NUMBER
:; Building Department (To be assigned by the Building Department.)
Seminole Road ( � _ 021-7
;j �� Atlantic Beach, Florida 32233-5445
Phone(904)247-5826 • Fax(904) 247-5845
"�o�t�wr E-mail: building-dept@coab.us Date routed: I ( ( t / 1 7
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: -7(.‘,71 �Amm U I-SC LRfoe- Department review required Yes No
reuilding�
Applicant: JPR.l l3 \`—(E(.._b i, o ( l_D FQ__,s/5lanning &Zoning j
Tree Administra or
\J G L� , l NC'NL C— 1— A m t Ly Pudic Works-,
Project: )
tu is tiliti�
t--CA Z�- 'l-'ublic Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. ied. ❑Not applicable
(Circle one.) Comments:
BUILDING ' ' to eta, g ficir"ifil-
PLANNING
&ZONING/ Reviewed by: '' "..- -� Date:// 7' /I 7
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. fNot applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: . Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ['Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
0L`1 rig, CITY OF ATLANTIC BEACH
.i�� 800 Seminole Road
is,
Atlantic Beach,Florida 32233
- �
; Telephone(904)247-5800
FAX(904)247-5845
J331�`
} REVISION REQUEST SHEET OR
CORRECTIONS TO REVIEW COMMENT
Date: //'1 L5l -/7 Received by: Resubmitted:
Permit Number: /ZES/7 -OZt{7
Original Plans Examinee. sProject Name:
Project Address:-71.( G►rb r
Contractor: �•�ij aw.l�.rs t,ct Contact Name: el(1) tA
C. • - one : Dy 624.ozyr Contact e-mail: rdet, buck.
'evision /Plan Check/Permit Fees Due: $ •
Description of Proposed Revision to Existing Permit:
/'tV i 5 i0,y rd.," lb,w 1-s ? 17
Additional Increase in Building Value: $ Additional S.F. •
Site Plan Revised: Public W/U Approval:
• By signin_ .• .w.I(print name) \t\-, affirm affirm that the above revision
is inclus. a of e propose. nges.
;
Signature of Contractor/ gent(Contractor must sign if increase in valuation) Date
Otice Use Only
Date: Approved: / Rejected: Notified by: _
Plan Review Comments:
Department review re•uired Yes No
.�anning&Zonin.
1,- ree nis rator _- Plans Examiner
.u, lc rror s - �Oil I/ 1
Date Created4/13/16 Re-v.3
Fire Services
r11..AP.1- City of Atlantic Beach APPLICATION NUMBER
J� IV J Building Department (To be assigned by the Building Department.)
� 800 Seminole Road 7
ili
�� Atlantic Beach, Florida 32233-5445
R E s 17 ' 021-7
Phone (904)247 5826 Fax(904)247 5845
01-119 E-mail: building-dept@coab.us Date routed: I ( l / ( 7
City web-site: http://www.coab.us
.iU17
APPLICATION REVIEW AND TRACKING FORM
De artment review required Yes No
Property Address: 7� � i A(��;�(�ISCC L� D� . p.. _.� a
Building
l
tanning &Zoning j
Applicant: Spkikx--, --(Ecb a i.� up�J�Tr -minis ra or
r�
�' PuEifcWofks,-
Project: � G---GO 4� 1 �v���E I— A M t L. � �,_�__��
� u Iic ti' U lit-
C T Z —Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: /Approved. ['Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by� i Date: /"621/
TREE ADMIN. Second Review: ❑Approved as revised. ['Denied. ['Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. Denied. ['Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
'LC 1-a- rhe- CITY OF ATLANTIC BEACH
J' ► v 1 800 Seminole Road
Atlantic Beach,Florida 32233
.� i! ' ' r NOV 1 6 2017 Telephone(904)247-5800
L FAX(904)247-5845
{
REVISION REQUEST SHEET OR
CORRECTIONS TO REVIEW COMMENT
Date: 1/-11/-/7 Received by: Resubmitted:
Permit Number: RE5/1 -02)17
Original Plans Examiner: T A c s Project Name: /u-1'.)cc 2c3•`cQ<•1c,-
Project Address:-'71,I arum« 1.4"4-'
Contractor: • id ' JM.rs , LLt. Contact Name: T, .(�l`��,n't
C. , -: on : ay (024.,OZ. + Contact e-mail: `4x(IL.. 60....1- oC i C.) 44 1 rC.,Oft -
'evision 'Plan Check/Permit Fee(s)Due: $ •
Description of Proposed Revision to Existing Permit:
r'tiv;$;o,> ex.,- lb 11" 4- — 1 4 2017
Additional Increase in Building Value: $ Additional S.F.
Site Plan Revised: Public W/U Approval:
By lignin_ :• w.I(print name) _ \\--_ .4 . C). ..%.,‘ affirm that the above revision
{ is inch's' e of e propose. 0 nges.
Signature of Contractor/ •gent(Contractor must sign if increase in valuation) Date
Opine Use Only
Date: Approved: #n Rejected: Notified by:
Plan Review Comments:
Department review required Yes No f
-42(40&rt2401•Ira-.
arming&Zonin
ree nls rator Plans Examiner
'•• IC WorCS
____L.....4 ...47
.7._
Date Crptnl4113/16 Rcv.3
Fire Services
.-i,:.b, City of Atlantic Beach APPLICATION NUMBER
4, . S�� Building Department (To be assigned by the Building Department.)
-- s 800 Seminole Road F '7
W' Atlantic Beach, Florida 32233-5445 � 9 RES 1 7 — U 2
,v LrNOVN®Y V 1
/ Phone (904)247-5826 • Fax(904)247 5845 2017 Date routed: I ( ' 7
_;;,�/ E-mail: building-dept@coab.us
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 7' ( j�R c CSC_ Lci•DE- Department review required Yes No
rguilding)
Applicant: S Pk i (-1f="(�,(.,b 1. 0 ( l,._QF- f anning &Zoniii�
Cm _ Tree ministra or
Project: jG(t3 I J\.)( t E A Mt C_ �' ��it cV�lor{zs
u istilitie-
L -(-- Z Public ba of ty
Fire Services
Review fee $ PO Dept Signature _..-.e/
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPATION STATUS
Reviewing Department First Review: fritApproved. ['Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING a2_/,PLANNING &ZONINGReviewed by: -• )� Date:
TREE ADMIN. Second Review: ❑Approved as revised. ['Denied. I 'Not applicable
"WORKS/ Comments:
[�
'UBLIC UTILITIES
1/- 2- /7
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
-
/ City of Atlantic Beach
ciok
PUBLIC UTILITIES DEPARTMENT
,Y) 1200 Sandpiper Lane
Atlantic Beach, FL 32233
(904) 247-5834
NEW WATER / SEWER TAP REQUEST
Date /1 - Z - 0 7 Project Address 76, / P,42,4-10/,5&.7
ice/
Number of Units 1 Commercial Residential ✓ Multi-Family
New Water Tap(s) & Meter(s) Meter Size(s) 3/6/ '
New Irrigation Meter Upgrade Existing Meter from to (size)
New Reclaim Water Meter Size New Connection to City Sewer
Applicant Name
Applicant Address
City State Zip
Phone Cell
Email
Applicant Signature
CITY STAFF USE ONLY
Application# 0E6 17 — 0 Zei 7 H-ot%A
Water System Development Charge $ 1, / 6/0 0(..)
Sewer System Development Charge $ qr (7 5 00 C S
Water Meter Only $ / e 5. 00
Reclaim Meter Only $
Water Meter Tap $
Sewer Tap $
Cross Connection $ <SO UC)
Other $
TOTAL $ 5, y z 0 v (Notes)
APPROVED Kayle Moore, P.E. Date y72._ I
Public Utilities Director or Authorized Signature
ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED
rS�.',Jri,, Building Permit Application
City of Atlantic Beach OFFICE COPY
800 Seminole Road,Atlantic Beach, FL 32233
\ 01:91- Phone: (904)247-5826 Fax: (904)247-5845
Job Address: -7k.. . i S� La n t A\4..k-,��wd HCl,Permit Number: ) 7 v `T /
Legal Description LA- is Ta.ra�z s c,rre Lc"4.4 S_.b 04.• r3 1.wA RE# /7Z 3% -of SS
Valuation of Work(Replacement Cost)$ Z 5-0,0 C1,c• Heated/Cooled SF ZS 35 Non-Heated/Cooled 6811
• Class of Work(Circle one): 120 Addition Alteration Repair Move Demo Pool Window/Door
• Use of existing/proposed structure(s)(Circle one): Commercial Residential
• If an existing structure,is a fire sprinkler system installed?(Circle one): es No N/A
• Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal— I Ree 1-1.. oa7!
Describe in detail the type of work to be performed:
' ` I,�_
c t="5‘CrAcA-eo,.. cS c... 0,ir_44 511"4 4_ "(14•Mik
Florida Product Approval# 1 for multiple products use product approval form
Property Owner Information `
Name: seri`'� n(a-3,..;\. ....n. , Luc Address: 13Q4C_ {etn'ki. e0 a 2
City �ac. ,.01.,_ State F1.. Zip 3 1...0..s Phone y 04 C,2h v145-
E-Mail
- ISE-Mail MY.. 6w,..k., c ay 6 S 611"4:( .Corr
Owner or Agent(If Agent, Power of Attorney or Agency Letter Required)
Contractor Information
Name of Company: 5 GA"4. 0.1 otal nt �
r Qualifying Agent: ,,e`K 3V t-`�,1--
�4`/1S
Address City State Zip
Office Phone Job Site/Contaft Number Li 011 62 Vo 01-(-15-
State
uiSState Certification/Registration#CSC-- 5-$ - VT E-Mail %Ks me,A,o-n.-
Architect Name&Phone# 5 tcMaC • gay- 77 - 4 33(
Engineer's Name& Phone# I;tut supe el .ne\- or,s.on'..g :Tett..ne.. 9o1(- 8$!o- 2401
Workers Compensation _
Exempt Insurer/Lease Employees/Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg
construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS, POOLS, FURNACES,BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTA , INANCING, CONSULT WITH YOUR LENDER O: i N ATTORNE : ORE
RECOR ri IN t YOUR ICE'pF COMMENCEMENT.
(Signature of Owner'r A:-nt including Contractor) (Signatur:o .ontractor)
Si ed and sworn to(or affi mgd jr.:before his. / day of Signed nd sworn to(or affir -.) t efo,r'ei�m= d L/ day of
�'c(„6�r- , 2.`'!7 ,by . ' .ifs_ r S Oc.fo tr 2-`3f 1 by - , C� PLOr
MIMI
�-
(Signature of Notary) ' ignature of riglir
40
CON!GIt .".pc :ii - .. TL NI G!NDLESPE. .:R
MY COMMISIO,fe r 924.451 111
A = MY COMMISSION#FF 924951 I
Personally Known OR EXPIRES:Octobar 6,20;9 rsonally Known OR �, EXPIRES:October 6,2019
F^rc TbrL'c"-I?J 'u cv'r.-ars dedThruNotayPuLlicUndervr'ter,
[ ]Produced Identification [ ]Produced Identification ; -_.__
Type of Identification: Type of Identification:
•
DO NOT WRITE BELOW- OFFICE USE ONLY
Applzca l e Coles:2010 FLORIDA BUILDING CODE
ReViewResircleolie).
Approved Disapproved , .
Approved vv/ Conditions
Review Initials/Date: i
Development Size
3abitable Space p ,2535S•FNon-Habitable c, F
npervious area
•
fiscellaneous Information
:,cupancy Group R- 3
pe of Construction V �j
tuber of Stories 2
ring District PV t
K. Occupancy Load
Sprinklers Required
d Zone )c
lIitions/Comments:
c ' .
. s` W TREE REMOVAL CALCULATIONS
S� City of Atlantic Beach
`tj -4r Community Development Department
800 Seminole Road Atlantic Beach, Florida 32233-5445
•&,01-11 9f- Phone: (904) 247-5826 Fax: (904) 247-5845 Email: Building-Dept@coab.us j
i
Permit: TREE17-0025 Applicant: Springfield Builders,LLC
i'��eSK
Address: 13846 Atlantic Blvd#2 pe<M ept
Site Address: 761 Paradise Lane Phone: 404-626-0245 tove415408 a ��'' I
RE#: 172376-0185 Email: ralph.buck.davis@gmail.ccp 609 •tab
('
TREE REMOVAL CALCULATIONS
0
1
REMOVED Legacy(non-oak) Legacy(oak) Oaks Palms Others Total
i Protected Trees Removed: 0 31 8 22.5 6 67.5
1, Mitigation Needed: 0 15.5 4 11.25 3 33.75
a
Trees Removed: 8",31"Oaks;6"Sweetgum; 10.5", 12"Palms
MITIGATION Legacy(non-oak) Legacy(oak) Oaks Palms Others Total
Credit for Trees Preserved: 0 0 0 0 0 0
Credit for Trees Relocated: 0 0 0 0 0 0
Credit for Trees Planted: 0 8 0 24 0 32
I Total: 0 8 0 24 0 32
Trees Preserved: None for credit.
Trees Relocated: None for credit.
i Trees Planted: 2-4"Live Oaks; 3-8"Sabal Palms
*Planted Legacy Tree species receive DOUBLE credit when replacing non-Legacy Trees.The Legacy Tree list includes Bald
i Cypress; Southern and Eastern Red Cedars; Winged and Florida Elms; Live and Sand Live Oaks; Hickory; Pecan; Pignut 1
Hickory;Loblolly Bay; Southern and Sweetbay Magnolias;Red and Florida Maples; and Tupelo. 1
i
ADDITIONAL MITIGATION REQUIRED (Mitigation Needed--Total) r
Legacy(non-oak) Legacy(oak) Oaks Palms Others Total
iNew Trees Planted: 0 0 0 0 0 0
4
5
or
Payment Into Tree Fund**: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
or
A Combination of the Above** **At least 50%of mitigation must be onsite.
Additional Notes: Mitigation is 1 inch preserved or planted for every 2 inches removed. Tree Fund rate is$116.00 per inch. Also
preserving 14", 2-12" Palms; 16",24" Pine; 8", 14", 22" Oaks; 6" Sweetgum. Paid outstanding mitigation for 11.5 inches totaling
$1,334.00 on 9/21/2017. Receipt: R2714.Check 611.
Status is in accordance with the City of Atlantic Beach code of ordinances in effect at the time of application submittal.
APPROVED J
DENIED LI
1 y/�i,.l c.,../-/iC-----
k TPO ADMINISTRATOR '.'12-3001
. z
r s # ; Cash Register Receipt Receipt Number
J kwr
City of Atlantic Beach R2714
DESCRIPTION I ACCOUNT QTY I PAID
PermitTRAK $1,334.00
TREE17-0025 Address: 761 PARADISE LN APN: 172376 0185 $1,334.00
TREE MITIGATION $1,334.00
TREE MITIGATION 11200003660000 0 $1,334.00
TOTAL FEES PAID BY RECEIPT: R2714 $1,334.00
Date Paid:Thursday,September 21, 2017
Paid By: SPRINGFIELD BUILDERS LLC
Cashier: BA
Pay Method: CHECK 611
Printed:Thursday,September 21,2017 9:22 AM 1 of 1 �y
malar
Earth Works, Inc.
�'�. 12501 Beach Blvd
/, Oak r *Bine 24• Jacksonville,FL 32246
pp,Vii;,
`4 �\ •I Sa Pal r, 12"
Oak 1 �� T
e Oak 22• J EARTH
!rte Pioc 16" I WORKS
- ---„„z.,,- .—,-------ii um
GARDEN CENTER
I1^
.a= V ' A
f \ l -.
r Oak 16,9,6• Lot 2a
� b �J fVACANT o P� 8 e
I H-::lt.la Sab alm`.5" I r�u� 0 T 2 N adise Lane
Atlantic Beach.FL
T 2g I 1111 i��� aai e T 26 II J
Lii
10' ''��
Q
1 ___—.__ ._ U pee May 23.2017
Dream Sale: 1"=2a 11(SR)
.„ 'a1ipmi_-
___I 6 Revisions:By Earthworks One
— ,- ,,,,-,,..1,_.'
•J:` , Rerieiaec:
--'e/ ' On Site Water servep is is Required
\a�. in Paradise Preserve Storage is not
Carper
Dtaiea
-�•fir•', Flow 8e
Sabal Pam 4"N Lot s- a 5,601 a 18, f..- Impervious area=2,584 af.
cn 1 -I---„
Ieef
- I ,5!-Jv4 14r1IF1iL 7S LA EASEMENT Ip• Ap M.r T
I i JEJt FJ�-
- Sad
FJ2.170+ r ..
La
r TIRE.y Required Fence `� SIte
PerILO.A ,Iy/�4B —
Plan
P
VAR, p��
. '�UI1ToF_wAy_
Earth Works, Inc.
S/L T FENCE 12501 Beach Blvd
cw,stt,.20.....1 Jacksonville,FL 32246
e.tu a a at Laos e.m not r--a x tiLu
Stc.1e;1t.1 neer see.,IC.The S,, .2
.res 0.e0 as.aP..c
0 co_n ..e a u.eitr M=e.s I.at I..,.
.-.u,.w-.e0 I...ae Lr ce e
���. ec.l�,i,rmt�rr 4•.es,6-tea ena.erely
eto a+er
Pita Mel he ce.f o moms.el w ret set codCO.
t� \. Oak 8" _ __— me as`CI 1 ere ate. nF. ..n(my `'J
6�- Pine 24" ...see a�_e w.,5 n a.rte...
,/ 0 los en.t r., M EARTH
/ i7I" a n�.. be e:c-<n pests end wear-5^a.
b.
/' �' r.
opal.. � cr_-rr...e�emcees to a she . WORKS
��`. �, Sab I Pa i;12' w Ile cis a cr bag rh a ..2«aa..m I..a t:.e,
,� d..3 ate d n r GARDEN CENTER
Oak 1• I II.^i o mak.. 2 ledInc.gm e.i..t.stma 11,11 t�
• - 33 hem mL,.w fie o.=+e pare...
r.,........-.....0.+.tr 00.Mal N elm,.e
-s.f., s.F.—s.C. s.f. £— f. ...•to thr.....•a t.aa e w rax.nes d...r
���Pine 1�' _ \ I I r°rme..:t e.> eb soh-c le.may cat n .v
as.nein.r,....n CC.s rxo...r e.an..n
la Me pasta
Sr [ nri
.elfamee Me fl .rhe 7.rw x.,t.! Lot 28
I
h t s rr-t hen is. acz ra e.ar...r...=na Paradise Preserve
�.,—_xe Paradise Lane
H a a•� v tarred c -.c ,tn rottas u.was, e.c:=, Atlantic Beach.FL
+ �� .I 0311.q-n_•r cr s.el.mt nr..a txsa u..
V `_ I t a er_,11,1,1-n
-!i, oak 1619.." IP! VACANT C A N T N r�=..=* ;.,�,i,on- a;.i
I _• r....0 be ,....Oetdl sac..v
ii 0 P�Saba�alm`5^ L 0 T 2 7 ___ n..e r.a.r.�Q
I�- O the rens..._.,,..t as',etch a.a......aa,�e Date: May 23.2017
"1111110"1.11 N as f Deming Scale: 1"=20' (KM()
2 g II iii,lll�lr. owl IlEreas Revisions,Br
.,, 1�' " Desi reed Earthworks.Inc
1! Iii 2 1 . .mm 1mrra mac �.
l�r ,�
-Jc80.ea
__. — L Q lea Mei
,• •• _
--..., , ,,_.:bal: . 12 (...) -;•-..•:. - -____---.----- r,-4.
ItA• rri ?ii 7.. -__Olh I ....we.TM
•
44�- m 6 On Site Water Storage is not Required
in Paradise Preserve per Rick Carper °a0"�
t � I end- I I i r1mrc..,_.
Sabal Pam 4"�t r- How l- wo, I
! , I
I Lot s-£=5,601 sS- t'!
I 18, Impervious area=2,584 s£ •
_ `
4EEE �S E4-FA.�IENI___� 7.5" EA EASf11ENi� �,. s!xnnn3 a:rr• nt.. vntz Dna& • �siHr 00011 1
,...--/.6.13 —TV ``-- 4 IMIn...ila.11•220.1. . OM cum
Erosion &
Is 1-704
I � v... Sediment
S=L" FENC3
Required Fence WI='gam"
- Pc H.O.A. mum cuRe
IIMI
PARADiSE LANE
VAR/A8,-RI iJr . w4 i
. .
,e- _...., --,
4-> Earth Works, Inc.
12501 Beach Blvd
Oak g" Pinc 24" Jacksonville,FL 32246
lei dopp, I,,,,ft
§=�
4f,-. Sabr Pa 12'
Oak le'
s.f.; s.f. s.f.I s.f. .f— �ti)p- \ EARTH
ti
t.�Pine 16" fi - � 'n
j,[WORKS
4'., Oak 16,9,6" 14 1 fi N.„ i -,
jiI"_ _ ji v VACANT
LU 27 N ParadiseParadise Lane
Preserve
iLot 28
A. , _. Atlantic Beach,FL
a Pa 5"
2 9 IJ{l rl� -. 21
Lot l j' _II tRI!'i 4 LST 26 J \ /
T.10, t•
t. vV)
Dale May 23,2017
Drawing Scale: 1"=20' (RSR)
r hal ID
Deemed Br Eanhwvksjne
Reesiene
II
r e
i On Site Water Storage is not Required
Chemical Toilet \" '\�� � i
in Paradise Preserve per Rick Carper
�f
!7 Drainage
Ij
i Flow q
!_ :: Lot s.f.=5,601 s.f.
(:I:�III RN i m 14" Inl I Impervious area=2,584 s.f. L
ti:1 l��li U w j I I_
III i�;/�, � 4NL'll�l�l� .; �` 7-5'.EA EASEMENT IPFI
�� SV __ __ ❑ SV
FIR 1 �s ,pst�� i-
.t, ( Constructjon '1
Ragweed Fence f�`dFence cuR8
P
ManagementJ
RIGHTr wt
Earth Works, Inc.
12501 Beach Blvd
4r1.1111,1."--Oak
Jacksonville,FL 32246
g"
6" ' Pine 24" —
1
Tr714!
`� �..� .„..._ _...,
Jr I Pal 1, 12" Wig H
Oak
1 /I Pine Straw
• J woks
Pine 16' 63 Bales \ Oak 22"
1 GARDEN CENTER
- 13- _
I
3g Splideaf Philodendron(4) I —.l -- -:- li _= O ( // \�
Jsa� V A C A-NT O� Let 28
rve
3g Podocarpus(22) '..>t r. I �. ; ( P Paradise
a Lane
Paratlke Lane
2 :.:••
® ' O Atlantic Beach,FL
MI UVACANT
9 ` ,,,I' [ OI LOT 27 `� J/
LST "44. ' 1111111 O'
x O,
4"Live Oak(1) a q;� k 11111'11'1; 2 a O;I L p T 2 6 now May 23,2017
nr/ O 0raaina Scale: 1'=20' (8 )
Dedpiw By.Earthworks,Inc
.: _. _ Oi N ReNraer
J�I 0, I II
a. .Ii_,
O
SO' 3g Walters Viburnum(14) CO
I q _ 3g Podocarpus(6) Q
Imo' --- y`r;5 U
8"Sabal Palm(3) to
250s.f. 1gBoxwood(;'i, �OOOfc<i;yytit.+=
'- ''`'''''''.;:'..'1;'-. 1g African his 00)
4'Live Oak(1) a,` 190 s.f. �'•',; •.•
�vt'r ----se ta- /;c..�s? 3g Muhly Grass(5)
3g Muhly Grass(8)—j�t�tmn`^i'� - —Ig African Iris(l l) jj -� { �15t'O 0'
��� ,..5%e I mFJIII_ �`` 7.5' EA EASEMENT -13 I W �,�1
//JJ —r Ems"
/ SY 1180 .f. `. -_
flp•1J 2 149s.f. (SNIZEI..me IJ LB 1!µ — LaPlanpe
4. RO�PerROA red Fence fi—�
YA1 a4 B
Pte' UNE vARL4E,IE 0,,,,.T-pr-W�y
• . • 4.
Earth Works, Inc.
12501 Beach Blvd
41 ,..P
Jacksonville,FL 32246
vOaks"
, --a *Pine 24•�� — — — -
1 PI
111111241*lcill
EARTH
13
J El X Tree Removed WORKS
• Pine 16" Oak 22" )
I ,:,.._Pine � p Tree Preserved GARDEN CENTER
I III �,�� 0 Tree Planted
ATree Removed b
L 0 T 2 9 1 a s V A� � No Mitigation _N laza 1
QO'., rn Oak(6,9.6" -B W PPa e�rm
�� x j --; VACANT J
Atlantic Beach.FL
Ili,,
sane S , •D o r 2 J
_ hill;! �'
4.Live Oak(I) ih 1q111A I! 2 6
(Legacy Double Inch C Q L 0 T oaic May 23.2017
H.
Orarinasdc 1'=20' ( )
Oadpraay.E.t.rub.inc
Sabal Palm I2'j Ravaiane
S Tree Mitigation
Tree inches removed: 67.5"
Tree Mitigation inches required: 34"
oaks" 4 IVA ---- Tree inches credit 0"
"� Tree inches planted: 40°
ji "' ' Mitigation payment required 8"Q$116/inch: $0.00��-NIN
Legacy Double Inc"Live Oakh C •'t) 4`Saba , I
�..14" No -- -- - --
---1--------------__ lj
r
�f----T. P 7.5'EA EASEMENTidj tPAD �x,t,�.,�tT�
/,�. 1�E "
Fes.' SY
�_____ CEErms \
-•- - Tree
= Inventory
MAIN agoP
LAS y E
/T- W r
t OFFICE COPY
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: PARADISE PRESERVE LOT 28 Builder Name: Marco Heating&Air Inc
Street: 761 PARADISE LANE Permit Office: DUVAL CNTY
City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number:
Owner: SPRINGFIELD BUILDERS.LLC Jurisdiction: 261300
Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3036.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=15.0 2681.00 ft2
b.Frame-Wood,Adjacent R=15.0 355.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1887.0 sqft.) Insulation Area
a.Under Attic(Vented) R=38.0 1618.00 ft2
6. Conditioned floor area above grade(ft2) 2535 b.Under Attic(Vented) R=19.0 224.00 ft2
Conditioned floor area below grade(ft2) 0 c.other(see details) R= 45.00 ft22
11.Ducts R ft
7. Windows(446.8 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 307
a. U-Factor: Dbl,U=0.34 350.80 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 200
SHGC: SHGC=0.24
b. U-Factor: Dbl,U=0.55 96.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 a.Central Unit 22.2 SEER:14.50
b.Central Unit 17.8 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 22.2 HSPF:8.20
SHGC: b. Electric Heat Pump 17.8 HSPF:8.20
Area Weighted Average Overhang Depth: 8.092 ft.
Area Weighted Average SHGC: 0.242 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (2535.0 sqft.) Insulation Area
EF:0.999
a.Slab-On-Grade Edge Insulation R=0.0 1534.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 693.00 ft2 None
c.other(see details) R= 308.00 ft2 15.Credits Pstat
Glass/Floor Area: 0.176 Total Proposed Modified Loads: 69.92 PASS
Total Baseline Loads: 74.36
I hereby certify that the plans and specifications covered by Review of the plans and •'�F'�ie STATE•••;•
this calculation are in compliance with the Florida Energy specifications covered by this , , .0.,:,
Door M Dorothy De.,e :• ;••` ' ,..,�
de. ON CNeDamthyDeane,CeUS.OLHIAatcoHeaeng&A'Inc'0 calculation indicates compliance .::1/4 ``
Mom Ne8Eng 8 Air.bic'.E=Eo1®Mrmcompenies mm • ciJ •(?' • .:±-,:-,` ``\\\'.C .
�o roth� Deane Reason I thieauthor elfin document tion with the Florida Energy Code. lnnl s''• ` ,; � �y
PREPARED Y: Date 2011-11-16133701 Before construction is completed t tg i -� + .�€ L"
DATE: this building will be inspected for ;0 if . '�� i.1. .
compliance with Section 553.908
I hereby certify tha this b I. . as d: ig is in com 1 fiance Florida Statutes. thor `y. �'
with the Florida Enbrgy •y:. OD WE
✓r
OWNER/AGENT: BUILDING OFFICIAL:
DATE: tr./7-/7 - .. DATE: �� 1r•27- '/7
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
10/31/2017 10:05 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: PARADISE PRESERVE LOT Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2535 Lot#
Owner: SPRINGFIELD BUILDERS.L Total Stories: 2 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Marco Heating&Air Inc Rotate Angle: 0 Street: 761 PARADISE LANE
Permit Office: DUVAL CNTY Cross Ventilation: No County: Duval
Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH,
Family Type: Single-family FL, 32233
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL JACKSONVILLE INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 DOWN 1534 15340
2 UP 1001 9009
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated
1 MAIN 1534 15340 Yes 2 1 1 Yes Yes Yes
2 BEDS 1001 9009 No 3 3 1 Yes Yes Yes
FLOORS
V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge lnsulatio MAIN 147.5 ft 0 1534 ft2 ____ 0.2 0.2 0.6
2 Floor over Garage BEDS ____ ____ 255 ft2 19 0.2 0.2 0.6
3 Raised Floor BEDS ____ ____ 53 ft2 19 0.2 0.2 0.6
4 Floor Over Other Space BEDS _ ____ 693 ft2 0 0.2 0.2 0.6
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2061 ft2 0 ft2 Medium 0.9 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1843 ft2 N N
10/31/2017 10:05 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) MAIN 38 Blown 751 ft2 0.1 Wood
2 Under Attic(Vented) BEDS 38 Blown 867 ft2 0.1 Wood
3 Under Attic(Vented) BEDS 19 Blown 134 ft2 0.11 Wood
4 Under Attic(Vented) MAIN 19 Blown 90 ft2 0.11 Wood
5 Knee Wall(Vented) MAIN 19 Blown 45 ft2 0.11 Wood
WALLS
/ Adjacent Cavity Width Height Sheathing Framing Solar Below
V # Omt To WaILTypP Space R-Value Ft In Ft In ArPa R-VaiiiP Fraction Absor Grade%
1 N Exterior Frame-Wood MAIN 15 38 0 10 0 380.0 ft2 0 0.23 0.05 0
2 E Exterior Frame-Wood MAIN 15 53 6 10 0 535.0 ft2 0 0.23 0.05 0
3 S Exterior Frame-Wood MAIN 15 21 0 10 0 210.0 ft2 0 0.23 0.05 0
4 W Exterior Frame-Wood MAIN 15 35 0 10 0 350.0 ft2 0 0.23 0.05 0
5 S Garage Frame-Wood MAIN 15 17 0 10 0 170.0 ft2 0 0.23 0.05 0
_ 6 W Garage Frame-Wood MAIN 15 18 6 10 0 185.0 ft2 0 0.23 0.05 0
7 N Exterior Frame-Wood BEDS 15 38 0 9 0 342.0 ft2 0 0.23 0.05 0
8 E Exterior Frame-Wood BEDS 15 29 0 9 0 261.0 ft2 0 0.23 0.05 0
9 S Exterior Frame-Wood BEDS 15 38 0 9 0 342.0 ft2 0 0.23 0.05 0
10 W Exterior Frame-Wood BEDS 15 29 0 9 0 261.0 ft2 0 0.23 0.05 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S Insulated MAIN None .35 3 8 24 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Vinyl Low-E Double Yes 0.55 0.25 96.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5
2 N 1 Vinyl Low-E Double Yes 0.34 0.24 36.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5
3 E 2 Vinyl Low-E Double Yes 0.34 0.24 72.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5
4 S 3 Vinyl Low-E Double Yes 0.34 0.24 24.0 ft2 10 ft 0 in 4 ft 0 in None Exterior 5
5 S 3 Vinyl Low-E Double Yes 0.34 0.24 16.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5
6 S 3 Vinyl Low-E Double Yes 0.34 0.24 7.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5
7 W 4 Vinyl Low-E Double Yes 0.34 0.24 8.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5
8 W 4 Vinyl Low-E Double Yes 0.34 0.24 10.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5
9 W 4 Vinyl Low-E Double Yes 0.34 0.24 8.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5
10 N 7 Vinyl Low-E Double Yes 0.34 0.24 8.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5
11 E 8 Vinyl Low-E Double Yes 0.34 0.24 12.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5
12 E 8 Vinyl Low-E Double Yes 0.34 0.24 6.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5
13 E 8 Vinyl Low-E Double Yes 0.34 0.24 30.6 ft2 2 ft 0 in 2 ft 0 in None Exterior 5
14 S 9 Vinyl Low-E Double Yes 0.34 0.24 8.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5
15 S 9 Vinyl Low-E Double Yes 0.34 0.24 61.2 ft2 2 ft 0 in 2 ft 0 in None Exterior 5
16 W 10 Vinyl Low-E Double Yes 0.34 0.24 20.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5
10/31/2017 10:05 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
17 W 10 Vinyl Low-E Double Yes 0.34 0.24 24.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5
GARAGE
V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 405 ft2 384 ft2 40 ft 10 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000427 2840.7 155.95 293.29 .405 7
HEATING SYSTEM
V # System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.2 22.2 kBtu/hr 1 sys#1
2 Electric Heat Pump Split HSPF:8.2 17.8 kBtu/hr 2 sys#2
COOLING SYSTEM
V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 14.5 22.2 kBtu/hr cfm 0.7 1 sys#1
2 Central Unit Split SEER: 14 17.8 kBtu/hr cfm 0.7 2 sys#2
HOT WATER SYSTEM
V # System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.999 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
V FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 307 ft2 Attic 77 ft2 Default Leakage Attic (Default) (Default) 1 1
2 Attic 6 200 ft2 Attic 50 ft2 Default Leakage Attic (Default) (Default) 2 2
10/31/2017 10:05 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 5
T
FORM R405-2014
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb [[ ]]Mar Apr [ ]May [[X]Jun [X]Jul [X AugX]SepOct ki Nov Dec
HeatinX)Jan X Feb [X]Mar ,1 Apr [ ]MaE ]Jun E ]Jul [ Aug E ]SeOct Nov �Dec
Venting Jan " Feb [[XX]]Mar A r [ ]Ma ]Jun ]Jul [ Au )Se X Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
10/31/2017 10:05 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 5 of 5
T ,
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
761 PARADISE LANE, ATLANTIC BEACH, FL, 32233
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame Wood,Exterior R=15.0 2681.00 ft2
b. Frame-Wood,Adjacent R=15.0 355.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1618.00 ft2
6. Conditioned floor area(ft2) 2535 b.Under Attic(Vented) R=19.0 224.00 ft2
7. Windows** Description Area c.other(see details) R= 45.00 ft2
a. U-Factor: Dbl,U=0.34 350.80 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:Attic 6 307
SHGC: SHGC=0.24 b.Sup: Attic,Ret:Attic,AH:Attic 6 200
b. U-Factor: Dbl,U=0.55 96.00 ft2
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 22.2 SEER:14.50
SHGC: b.Central Unit 17.8 SEER:14.00
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a. Electric Heat Pump 22.2 HSPF:8.20
Area Weighted Average Overhang Depth: 8.092 ft. b.Electric Heat Pump 17.8 HSPF:8.20
Area Weighted Average SHGC: 0.242
8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1534.00 ft2 a.Electric EF: 1
b.Floor Over Other Space R=0.0 693.00 ft2
c.other(see details) R= 308.00 ft2 b. Conservation features
None
15.CreditsPstat
I certify that this home has c•a plied with the Florida Energy Efficiency Code for Building �Nir 8Tq
Construction through the . •o - energy savin• e. res which will be installed (or exceeded) •'• 0%................._44 ..•
in this home before fina ns••ction. Oth- 0., ane EPL Display Card will be completed 4ti.. ,. ,,-....r,`:
based on installed Cote co 'Ha, feat e 'i./tttt„ °;� %0 1
1. arm. Z.,' :
(24 Builder Signature: •- Date: /i /1777 `• ,1 ;a
�
e
Address of New Home: 76,( 7t.-tAi( . Lw„ City/FL Zip: A /€J ' v`'�.•• •'.
Ft. 72z2,3 .
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/31/2017 10:05 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number.
Jacksonville,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
4" 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
7' R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through 8402.4.4.
R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections 8402.4.1.1 and 8402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 4024.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be fumed off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
/ R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
0/ R402.4.3 Fenestration air leakage.W indows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 dm
• per sgJare toot(1.5 Usrm2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMAWDMNCSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
7 8402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
8403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
/
/' R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak tree'by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
7/21/2015 11:18 AM EnergyGauge®USA-FlaRes2014 -Section 8405.4.1 Com Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS- (Continued)
R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the
/' design air flow rate when tested in accordance with ASHRAE 193.
[7 R403.2.3 Building Cavities(Mandatory).Building framing cavities shall not be used as ducts or plenums.
/- R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13'C)shall be insulated to a minimum of R-3.,
0 R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused
by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the
material.Adhesive tape shall not be permitted.
• R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
R403.4.3 Heat traps(Mandatory). Storage water heaters riot equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies
R403.4.4.1 Storage water heater temperature controls
. R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38`C to 60°C).
▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
rR403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
▪ R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a till angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the
efficacy requirements of Table R403.5.1.
Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an
electronically commutated motor.
R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical
ventilation shall meet the following criteria:
t. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality,
shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawfspaces,attached closed
garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a
minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise.
)' R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
7/21/2015 11:18 AM EnergyGauge®USA-FlaHes2014 -Section 8405.4.1 Corn Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS- (Continued)
8403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
▪ 8403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section 8403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section 8403.6.1.
R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
7 R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting oft the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
C R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
o 8403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-ott switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oilfired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
▪ thermal efficiency of 82 percent for heaters manufactured on or atter April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously buming pilot lights.
• R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
o 8403.0.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
p 8403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
• solar energy source computed over an operating season.
RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
R405.2,Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
8405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roots do not have sufficent space,R-10 is allowed.
7/21/2015 11:18 AM EnergyGauge®USA-FlaRes2014 -Section 8405.4.1 Corn Page 3 of 3
•
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: PARADISE PRESERVE LOT 28 Builder Name: Marco Heating&Air Inc
Street: 761 PARADISE LANE Permit Office: DUVAL CNTY
City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number:
Owner: SPRINGFIELD BUILDERS.LLC Jurisdiction: 261300
Design Location: FL,Jacksonville
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation. ./
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
//v jp.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed. ✓
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
10/31/2017 10:05 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: PARADISE PRESERVE LOT 28 Builder Name: Marco Heating&Air Inc
Street: 761 PARADISE LANE Permit Office: DUVAL CNTY
City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number:
Design Location: FL,Jacksonville Jurisdiction: 261300
Cond.Floor Area:: 2535 sq.ft. Cond.Volume: 24349 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data: CFM(50):
C: n: R:
ELA:
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: EqLA:
ACH:
SLA:
ACH(50)* :
* For prescriptive projects, tested leakage must be
<=7 ACH(50). For performance projects, tested
leakage must be<=the ACH(50)shown on Form
R405-2014 for this project.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour
in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by
either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing shall be conducted by either �Y1E ST
41,....hereby certify that the above envelope leakage individuals as defined in Section .•'•p4:................ATFo
performance results demonstrate compliance 553.993(5)or(7), Florida Statutes or 41';� = ';
with Florida EnergyCode requirements in = r'� ;°;;,e....1O
____ q individuals licensed as set forth in :a� :mittfir"j,.•
„ 1.
accords - witlri-S-ection R4 4.1.2. Section 489.105(3)(f), (g), or(i)or an g€ I '7°
2 approved third party. A written report 1 O a
of the results of the test shall be signed .......1°t°
SIGNATURE: r
` by the third party conducting the test • it,'
and provided to the code official. CE
OD WE
• . '�
PRINTED NAME:
BUILDING OFFICIAL: ��
DATE:
DATE: l(• L 2 -( )
10/31/2017 10:05 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1
BuildingAnal sis Job: PARADISE PRESERVE LO...
wrightsoft y Date: OCT 31 ,2017
Entire House By: MARCO HEATING AND AIR
Marco Heating & Air Inc Plan: 2589 SQ FT
720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711
Pro'ect Information
For: PARADISE PRESERVE LOT 28, SPRINGFIELD BUILDERS. LLC
761 PARADISE LANE,ATLANTIC BEACH, FL 32233
Desi• n Conditions
Location: Indoor: Heating Cooling
Jacksonville Intl AP, FL, US Indoor temperature(°F) 70 75
Elevation: 33 ft Design TD(°F) 38 18
Latitude: 30°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 11.0 51.2
Drybulb(°F) 33 93 Infiltration:
Daily range(°F) - 18 ( M ) Method Simplified
Wet bulb(°F) - 77 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 0
Heatin•
Component Btu h/ft2 Btuh %of load
Walls 3.3 8417 23.7
Glazing 14.4 6453 18.2 D. s
Doors 0 0 0
Ceilings 1.0 1797 5.1
Floors 3.8 7001 19.8 ____________kfltrIicn
Infiltration 2.0 5350 15.1
Ducts 6422 18.1 ��
Piping 0 0
Humidification 0 0 lir Floors
Ventilation 0 0
Adjustments 0
Total 35439 100.0
Coolin•
Component Btu h/ft2 Btuh %of load
Walls 1.9 4952 17.1
Glazing 13.0 5806 20.0 V1kl Irterr>al C3sins
Doors 0 0 0
Ceilings 1.4 2573 8.9
Floors 0.0 77 0.3
Infiltration 0.5 1263 4.3
Ducts 8846 30.5 Gaa
Ventilation 0 0
Internal gains 5520 19.0 Ducts
Blower 0 0 C,eili
Adjustments 0
Total 29037 100.0 Irfi raicn
Latent Cooling Load=8628 Btuh
Overall U-value=0.095 Btuh/ft2-°F
Data entries checked.
� wrightsoft- 2017-Nov-1613:22:20
�1.C.1� Right-Suite®Universal 2017 17.0.23 RSU17889 Page 1
/
..761 PARADISE LANE\BUCKY DAVIS 2535 SF LEFT.rup Calc=MJ8 Front Door faces: S
-fii- wrightsott• Right-J® Worksheet Job: PARADISE PRESERVE LOT 28
Entire House Date: OCT 31 ,2017
By: MARCO HEATING AND AIR
Marco Heating &Air Inc Plan: 2589 SQ FT
720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711
1 Room name Entire House DOWN
2 Exposed wall 281.5 ft 147.5 ft
3 Room height 9.6 ft 10.0 ft
4 Room dimensions
5 Room area 2535.3 ft' 1534.3 ft'
I
I
I
Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load
number (Btuh/ft'-°FI (Btuh/f t') I or perimeter (ft) (Btuh) I or perimeter (ft) I (Btuh)
IHeat I Cool I Gross I N/P/S Heat I Cool I Gross I N/P/S I Heat I Cool
6 V1 12D-Osw 0.086 n 3.23 2.00 722 582 1877 1161 380 248 800 495
-(' 10D-v 0.550 n 20.63 9.40 96 0 1980 902 96 0 1980 902
. -G 4A5-2ov 0.340 n 12.75 9.90 8 0 102 79 0 0 0 0
4A5-2ov 0.340 n 12.75 9.90 36 0 459 356 36 0 459 356
11 W 12D-Osw 0.086 e 3.23 2.00 796 675 2178 1348 535 463 1493 924
-G 4A5-2ov 0.340 e 12.75 26.13 12 0 153 314 0 0 0 0
-G 4A5-2ov 0.340 e 12.75 26.13 6 0 77 157 0 0 0 0
-G 4A5-2ov 0.340 e 12.75 26.13 31 0 390 800 0 0 0 0
-G 4A5-2ov 0.340 e 12.75 9.90 72 72 918 712 72 72 918 712
Vi 12D-Osw 0.086 s 3.23 2.00 552 436 1405 870 210 163 526 325
-G 10D-v 0.340 s 12.75 6.93 24 24 306 166 24 24 306 166
-G 4A5-2ov 0.340 s 12.75 9.90 8 8 102 79 0 0 0 0
-G 4A5-2ov 0.340 s 12.75 9.90 16 16 204 158 16 16 204 158
- (3 4A5-2ov 0.340 s 12.75 9.90 61 61 780 606 0 0 0 0
-(' 4A5-2ov 0.340 s 12.75 9.90 7 7 89 69 7 7 89 69
V/ 120-0sw 0.086 w 3.23 2.00 611 541 1745 1079 350 324 1045 646
-G 4A5-2ov 0.340 w 12.75 26.13 20 0 255 523 0 0 0 0
-G 4A5-2ov 0.340 w 12.75 9.90 8 8 102 79 8 8 102 79
-G 4A5-2ov 0.340 w 12.75 9.90 10 10 128 99 10 10 128 99
-G 4A5-2ov 0.340 w 12.75 9.90 8 8 102 79 8 8 102 79
-G 4A5-2ov 0.340 w 12.75 26.13 24 0 306 627 0 0 0 0
P 12C-Osw 0.091 - 3.41 1.39 355 355 1211 494 355 355 1211 494
C 16B-30ad 0.032 - 1.20 1.72 2 2 2 3 1 1 1 2
C 16B-38ad 0.026 - 0.98 1.40 1841 1841 1795 2570 841 841 820 1174
F 19C-19cscp 0.049 - 0.64 0.30 255 255 162 77 0 0 0 0
F 22A-tpm 1.180 - 44.25 0.00 1587 155 6838 0 1534 148 6527 0
6 c)AED excursion
Envelope loss/gain I I 0 0
236671 13408 I 16711 6682
12 a) Infiltration 5350 1263 2944 695
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants Q 230 4 920 1 230
Appliances/other 4600 3400
Subtotal(lines 6 to 13) 29017 20191 19654 11007
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 29017 20191 19654 11007
15 Duct loads 22% 44% 6422 8846 19% 47% 3766 5227
I I
Total ruired(cfin) 1 1 I 313331 29013331 1 1 2344001 1627 01
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft' 2017-Nov-16 13:22:20
9 Right-Suite®Universal 2017 17.0.23 RSU17889 Page 1
...761 PARADISE LANE\BUCKY DAVIS 2535 SF LEFT.rup Calc=MJ8 Front Door faces: S
-4- wrightsoft. Right-J® Worksheet Job: PARADISE PRESERVE LOT 28
Entire House Date: OCT 31 ,2017
By: MARCO HEATING AND AIR
Marco Heating &Air Inc Plan: 2589 SQ FT
720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711
1 Room name UP
2 Exposed wall 134.0 ft
3 Room height 9.0 ft
4 Room dimensions
5 Room area 1001.0 ft'
I I i I i • 1
Ty Construction U-value OrHTM Area (f t') Load Area Load
number (Btuh/ft'-°F I (Btuh/ft') or perimeter (ft) (Btuh) or perimeter
IHeat Coot Gross N/P/S Heat I Cool I Gross I N/P/S I Heat I Cool
6 VI 12D-Osw 0.086 n 3.23 2.00 342 334 1077 666
. -G 10D-v 0.550 n 20.63 9.40 0 0 0 0
. -G 4A5-2ov 0.340 n 12.75 9.90 8 0 102 79
-G 4A5-2ov 0.340 n 12.75 9.90 0 0 0 0
11 VI 12D-Osw 0.086 e 3.23 2.00 261 212 685 424
-G 4A5-2ov 0.340 e 12.75 26.13 12 0 153 314
-G 4A5-2ov 0.340 e 12.75 26.13 6 0 77 157
-G 4A5-2ov 0.340 e 12.75 26.13 31 0 390 800
-G 4A5-2ov 0.340 e 12.75 9.90 0 0 0 0
VI 120-Osw 0.086 s 3.23 2.00 342 273 880 544
-G 10D-v 0.340 s 12.75 6.93 0 0 0 0
-G 4A5-2ov 0.340 s 12.75 9.90 8 8 102 79
-G 4A5-2ov 0.340 s 12.75 9.90 0 0 0 0
-G 4A5-2ov 0.340 s 12.75 9.90 61 61 780 606
-G 4A5-2ov 0.340 s 12.75 9.90 0 0 0 0
VI 120-05w 0.086 w 3.23 2.00 261 217 700 433
-G 4A5-2ov 0.340 w 12.75 26.13 20 0 255 523
-moi 4A5-2ov 0.340 w 12.75 9.90 0 0 0 0
4A5-2ov 0.340 w 12.75 9.90 0 0 0 0
-G 4A5-2ov 0.340 w 12.75 9.90 0 0 0 0
-G 4A5-2ov 0.340 w 12.75 26.13 24 0 306 627
P 12C-Osw 0.091 - 3.41 1.39 0 0 0 0
C 16B-30ad 0.032 - 1.20 1.72 1 1 1 2
C 16B-38ad 0.026 - 0.98 1.40 1000 1000 975 1396
F 19C-19cscp 0.049 - 0.64 0.30 255 255 162 77
F 22A-tpm 1.180 - 44.25 0.00 53 7 311 0
6 c)AED excursion
Envelope loss/gain I I 6957 0
6726 I
12 a) Infiltration 2407 568
b) Room ventilation 0 0
13 Internal gains: Occupants Q 230 3 690
Appliances/other 1200
Subtotal(lines 6 to 13) 9363 9184
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 9363 9184
15 Duct loads 28% 39% 2656 3619
I I Arareqmoth
red(cfm) I I I 125931 125931 I I I I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri 17Y901Fi` 2017-Nov-1613:22:20
9 Right-Suite®Universa1201717.0.23 RSU17889 Paget
...761 PARADISE LANE\BUCKY DAVIS 2535 SF LEFT.rup Calc=MJ8 Front Door faces: S
Project SummaryJob: PARADISE PRESERVE LO...
wrightsoft Date: OCT 31 ,2017
Entire House By: MARCO HEATING AND AIR
Marco Heating & Air Inc Plan: 2589 SQ FT
720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711
Pro'ect Information
For: PARADISE PRESERVE LOT 28, SPRINGFIELD BUILDERS. LLC
761 PARADISE LANE,ATLANTIC BEACH, FL 32233
Notes: ORIENTATION-S-FRONT DOOR
DOWN 2.0 TON 5KW& UP 1.5 TON 5KW
Desi•n Information
Weather: Jacksonville Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 33 °F Outside db 93 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 18 °F
Daily range M
Relative humidity 50
Moisture difference 51 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29017 Btuh Structure 20191 Btuh
Ducts 6422 Btuh Ducts 8846 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 35439 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 29037 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 6556 Btuh
Ducts 2072 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling
Area(ft2) 2535 2535 Equipment latent load 8628 Btuh
Volume(ft3) 24349 24349
Air changes/hour 0.32 0.16 Equipment Total Load(Sen+Lat) 37665 Btuh
Equiv.AVF(cfm) 130 65 Req.total capacity at 0.70 SHR 3.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make n/a
Trade n/a Trade n/a
Model n/a Cond n/a
AHRI ref n/a Coil n/a
AHRI ref n/a
Efficiency n/a Efficiency n/a
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 0 cfm Actual air flow 0 cfm
Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat n/a Load sensible heat ratio 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri ht501Ft" 2017-Nov-1613:21:53
L g Right-Suite®Universal 2017 17.0.23 RSU17889 Page 1
...761 PARADISE LANE\BUCKY DAVIS 2535 SF LEFT.rup Calc=MJ8 Front Door faces: S
Project Summa Job: PARADISE PRESERVE LO...
-fiii- wrightsoft 17
DOWN By:Dae MARCO HEATING AND AIR
Marco Heating & Air Inc Plan: 2589 SQ FT
720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711
Pro'ect Information
For: PARADISE PRESERVE LOT 28, SPRINGFIELD BUILDERS. LLC
761 PARADISE LANE,ATLANTIC BEACH, FL 32233
Notes: ORIENTATION-S-FRONT DOOR
DOWN 2.0 TON 5KW&UP 1.5 TON 5KW
Desi•n Information
Weather: Jacksonville Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 33 °F Outside db 93 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 18 °F
Daily range M
Relative humidity 50 %
Moisture difference 51 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 19654 Btuh Structure 11007 Btuh
Ducts 3766 Btuh Ducts 5227 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 23420 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 16234 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3441 Btuh
Ducts 1236 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1534 1534 Equipment latent load 4677 Btuh
Volume (ft3) 15341 15341
Air changes/hour 0.28 0.14 Equipment Total Load (Sen+Lat) 20911 Btuh
Equiv.AVF(cfm) 71 36 Req.total capacity at 0.70 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model 25HCE424A00300 Cond 25HCE424A00300
AHRI ref 9674745 Coil FB4CNP025L
AHRI ref 9674745
Efficiency 8.2 HSPF Efficiency 11.5 EER, 14.5 SEER
Heating input Sensible cooling 15540 Btuh
Heating output 22200 Btuh @ 47°F Latent cooling 6660 Btuh
Temperature rise 27 °F Total cooling 22200 Btuh
Actual air flow 740 cfm Actual air flow 740 cfm
Air flow factor 0.032 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.78
Capacity balance point=35°F
Backup:
Input=7 kW, Output=24884 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-Nov-16 13:21:53
S
wrightsoft- Right-Suite®Universal 2017 17.0.23 RSU17889 Paget
ACk ...761 PARADISE LANE\BUCKY DAVIS 2535 SF LEFT.nip Calc=MJ8 Front Door faces: S
P
4 wrightsoft Project SummaryJob: PARADISE PRESERVE LO...
PrDate: OCT 31 ,2017
UP By: MARCO HEATING AND AIR
Marco Heating & Air Inc Plan: 2589 SQ FT
720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711
Pro'ect Information
For: PARADISE PRESERVE LOT 28, SPRINGFIELD BUILDERS. LLC
761 PARADISE LANE,ATLANTIC BEACH, FL 32233
Notes: ORIENTATION-S-FRONT DOOR
DOWN 2.0 TON 5KW& UP 1.5 TON 5KW
Desi• n Information
Weather: Jacksonville Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 33 °F Outside db 93 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 18 °F
Daily range M
Relative humidity 50
Moisture difference 51 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 9363 Btuh Structure 9184 Btuh
Ducts 2656 Btuh Ducts 3619 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12019 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 12803 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3115 Btuh
Ducts 836 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft.) 1001 1001 Equipment latent load 3951 Btuh
Volume(ft3) 9008 9008
Air changes/hour 0.39 0.19 Equipment Total Load(Sen+Lat) 16754 Btuh
Equiv.AVF(cfm) 58 29 Req.total capacity at 0.70 SHR 1.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model 25HCE418A00300 Cond 25HCE418A00300
AHRI ref 9671302 Coil FB4CNP018L
AHRI ref 9671302
Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 12460 Btuh
Heating output 17600 Btuh @ 47°F Latent cooling 5340 Btuh
Temperature rise 27 °F Total cooling 17800 Btuh
Actual air flow 593 cfm Actual air flow 593 cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.76
Capacity balance point=24°F
Backup:
Input=4 kW, Output= 13732 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft 2017-Nov-1613:21:53
g Right-Suite®Universal201717.0.23 RSU17889 Page 3
...761 PARADISE LANE\BUCKY DAVIS 2535 SF LEFT.rup Calc=MJ8 Front Door faces: S
- Manual S Compliance Report Job: PARADISE PRESERVE LO...
wrightsoft Date: OCT 31 ,2017
DOWN By: MARCO HEATING AND AIR
Marco Heating & Air Inc Plan: 2589 SQ FT
720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711
Project Information
For: PARADISE PRESERVE LOT 28, SPRINGFIELD BUILDERS. LLC
761 PARADISE LANE, ATLANTIC BEACH, FL 32233
Cooling Equipment
Design Conditions
Outdoor design DB: 92.7°F Sensible gain: 16234 Btuh Entering coil DB: 78.2°F
Outdoor design WB: 77.1°F Latent gain: 4677 Btuh Entering coil WB: 64.1°F
Indoor design DB: 75.0°F Total gain: 20911 Btuh
Indoor RH: 50% Estimated airflow: 740 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HCE424A00300+FB4CNP025L
Actual airflow: 740 cfm
Sensible capacity: 15540 Btuh 96%of load
Latent capacity: 6660 Btuh 142%of load
Total capacity: 22200 Btuh 106%of load SHR: 70%
Heating Equipment
Design Conditions
Outdoor design DB: 32.5°F Heat loss: 23420 Btuh Entering coil DB: 68.4°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HCE424A00300+FB4CNP025L
Actual airflow: 740 cfm
Output capacity: 22200 Btuh 95%of load Capacity balance: 35 °F
Supplemental heat required: 1220 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 740 cfm
Output capacity: 7.3 kW 106%of load Temp. rise: 50 °F
Meets are all requirements of ACCA Manual S.
2017-Nov-16 13:21:53
' wrughtsoft Right-Suite®Universal 2017 17.0.23 RSU17889 Page 1
Aa5K ...761 PARADISE LANE\BUCKY DAVIS 2535 SF LEFT.rup Calc=MJ8 Front Door faces: S
Manual S Compliance Report Job: PARADISE PRESERVE LO...
wrightsoft
Date: OCT 31 ,2017
UP By: MARCO HEATING AND AIR
Marco Heating & Air Inc Plan: 2589 SQ FT
720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711
Project Information
For: PARADISE PRESERVE LOT 28, SPRINGFIELD BUILDERS. LLC
761 PARADISE LANE,ATLANTIC BEACH, FL 32233
Cooling Equipment
Design Conditions
Outdoor design DB: 92.7°F Sensible gain: 12803 Btuh Entering coil DB: 77.7°F
Outdoor design WB: 77.1°F Latent gain: 3951 Btuh Entering coil WB: 63.8°F
Indoor design DB: 75.0°F Total gain: 16754 Btuh
Indoor RH: 50% Estimated airflow: 593 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HCE418A00300+FB4CNP018L
Actual airflow: 593 cfm
Sensible capacity: 12460 Btuh 97%of load
Latent capacity: 5340 Btuh 135%of load
Total capacity: 17800 Btuh 106%of load SHR: 70%
Heating Equipment
Design Conditions
Outdoor design DB: 32.5°F Heat loss: 12019 Btuh Entering coil DB: 68.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HCE418A00300+FB4CNP018L
Actual airflow: 593 cfm
Output capacity: 17600 Btuh 146%of load Capacity balance: 24 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 593 cfm
Output capacity: 4.0 kW 114%of load Temp. rise: 50 °F
Meets are all requirements of ACCA Manual S.
2017-Nov-16 13:21:53
wrightsoft Right-Suite®U niversal 2017 17.0.23 RSU17889 Page2
...761 PARADISE LANE\BUCKY DAVIS 2535 SF LEFT.rup Calc=MJ8 Front Door faces: S
•
SPRINGFIELD BUILDERS PLAN: CUSTOM
LOT#: 28 SUBDIVISION: PARADISE PRESERVE
CARRIER 2.0 TON HEAT PUMP SYSTEM SEER: _14_ HSPF: _8.2_
CARRIER 1.5 TON HEAT PUMP SYSTEM SEER: _14_ HSPF: _8.2_
DESIGN COOL BTUH: 42000_ AVAILABLE STATIC PRESSURE: _1:1_
TOTAL CFM: 1285 TOTAL EFFECTIVE LENGTH: 300_
PERFORMANCE METHOD: DUCT MATERIAL: R6 VINYL FLEX
SUPPLY BRANCH DETAIL TABLE
ROOM NAME COOLING CFM BRANCH SIZE LINEAR FT DUCT MATERIAL
LIVING 100 CFM 6" 20' VINYL FLEX
DINING 100 CFM 6" 20' VINYL FLEX
POWDER 35 CFM 4" 12' VINYL FLEX
MUDD 35 CFM 4" 12' VINYL FLEX
KITCHEN 100 CFM 6" 12' VINYL FLEX
BATH 3 35 CFM 4" 24' VINYL FLEX
LAUNDRY 35 CFM 4" 18' VINYL FLEX
LOFT 100 CFM 6" 18' VINYL FLEX
BR 4 100 CFM 6" 18' VINYL FLEX
BR3 WIC 35 CFM 4" 24' VINYL FLEX
BR3 100 CFM 6" 12' VINYL FLEX
BATH 2 35 CFM 4" 18' VINYL FLEX
BR2 100 CFM 6" 15' VINYL FLEX
BR2 WIC 35 CFM 4" 12' VINYL FLEX
MBR (2) 100 CFM (2) 6" 30' VINYL FLEX
MBA 35 CFM 4" 8' VINYL FLEX
MBR WIC 1 35 CFM 4" 15' VINYL FLEX
MBR WIC 2 35 CFM 4" 15' VINYL FLEX
MBA TOILET 35 CFM 4" 15' VINYL FLEX
TOTALS 1285 CFM 300 LN (FT)
SUPPLY TRUNK DETAIL TABLE
LOCATION DESIGN BTUH TRUNK SIZE DUCT MATERIAL
FROM UNIT TO 1ST DISTR BOX 12202 10" VINYL FLEX
FROM UNIT TO 1ST DISTR BOX 21054 14" VINYL FLEX
1
..........,,, ap. i_ 202 2t,
t r-
- VI�
ii
}
! ' Id 'cvA,s Iwwl 61
awl '
`fi.1 awwl 4.
} idle
: , fm III t _:l :L.'o , Pi,_,,w.. -
or ,,, ,
�M D.:,el ® I II s
a f-- :f`� -, S, a
I % it In I --.-S' ! I I ...;i
ri, i ;.:,II .s ,. 140, a.
70 F
II—
� l - q
1 t_
-13
.—.zr+ :: ra-airs:dS+=dS ;r+ ,rte
Z est.
e
1 o xrrr • ' m ,:e7 Mew
poi .
u
Iii ) - ,--77-- �
Iza 2 ?a u
;e£ 1!'t :u : tr374 i:. 'i. `TM Ilrs
lii mum imilliffaisiiiiiiii (Cli,'-q-
Teem-= ''' 'II:: 1
I21 i ___J-• . rr
h it---,*, '-i - a.t. —C..
G I I44
M t. I! '
til
st roL 4_
Ir.—
.,.....1111111411,7;g
IIIII�
rs. �. v
j
NIL
a K ililliMMil
iP& P ci Ili r e € # PIT
� - r •JI
6 14�' o1
1
41
'` r qr • � C u
_
Iw
._ .
. R7 i i
364
3d f
1..4§1_1
ig fin 1 ;psi! Future Residence Springfield Builders, LLC �--�
6 f {I €s 4' a Lot 28 1 13846 Atlantic Blvd.#204 --
' Paradise Preserve Jacksonville,FL 32225
1 > PH :404-626-0245
• ,i 'tel Atlantic Beach, FL 32233
OFFICE COPY
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA
Project Name: LSC" �-� Permit #Res/? OcW '7
Project Address: 7(0 ( ?err-6-,. L�.••i p, ,�tc►c�- F\, 3 223 3
As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s)
for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact
your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide
product approval may be obtained at: www.floridabuilding.orre
Category/Subcategory 1 Manufacturer r Product Description 1 Limitation of Use State# Local#
A. EXTERIOR DOORS + _
1. Swinging 71 rEb /S/80.1
2. Sliding ���a l� /t./448. 3
3. Sectional
4. Roll up C O .cr L.4 /57(-(
5. Automatic
6. Other
B. WINDOWS
1. Single hung 5,i Vex-(; .%( Z-10 (9 WS".
2. Horizontal slider
3. Casement
4. Double hung
5. Fixed S:14t.r\er.4_ 7-41 5-0 101918 . Z
6. Awning
7. Pass-through
8. Projected
9. Mullion
10. Wind breaker
11. Dual action
y,
12. Other
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
C. PANEL WALL
1. Siding IA-,,re,; 13'WI
2. Soffits 4....:42,41. 13 7.425—
,
3. EIFS
4. Storefronts
5. Curtain walls
6. Wall louvers
7. Glass block
8. Membrane
9. Greenhouse
10. Synthetic stucco
11. Other
D. ROOFING PRODUCTS ,
1. Asphalt shingles pvf c,As C.,cin•�s , /4,74.1
2. Underlayments "fart]k 0 30 lb f eI /a 3c4*.7
3. Roofing fasteners
4.Nonstructural metal roof
5. Built-up roofing
6. Modified bitumen
7. Single ply roofing
8. Roofing tiles
9. Roofing insulation
10. Waterproofing
11. Wood shingles/shakes
12. Roofing slate _
13. Liquid applied roofing
14. Cement-adhesive coats
15. Roof tile adhesive
16. Spray applied polyurethane
roof
17. Other
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local #
E. SHUTTERS
1. Accordion
2. Bahama
3. Storm panels
4. Colonial
5. Roll-up
6. Equipment
7. Other
F. STRUCTURAL
COMPONENTS
1. Wood connector/anchor 35"
2. Truss plates
3. Engineered lumber , t.3.
4. Railing
5. Coolers-freezers
6. Concrete admixtures
7. Material
8. Insulation forms
9. Plastics
10. Deck-roof
11. Wall
12. Sheds
13. Other
G. SKYLIGHTS
1. Skylight
2. Other
Category/Subcategory Manufacturer Product Description 'Limitation of Use State# Local#
H. NEW EXTERIOR
ENVELOPE PRODUCTS ,
1.
2.
In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the
Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation
instructions along with this Product Approval Sheet.
I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones
listed in this document must be approved by the Building Official.
S en�.c� L ,�1 .. , LLL JLM6 K
(Contractor Name) (Print Name) (Signa ,e)
Company Name: __ �-i Jc.‘- a-vs, L tom. 1111imi
Mailing Address: 3 St-V. o•.�� 71.4r), 44. 2,04
City: 4�k co..��\ State: F( Zip Code: 3 21-1-5-
Telephone
Zz-5-
Telephone Number: ( ) Fax Number: ( ) 1
Cell Phone Number: f OL() Zto 02-'1 E-mail Address: �o.� -• H�jc.. ca►.J`S too., c..
1� 4
d
Earth Works, Inc.
/ _�, / 12501 Beach Blvd
,\ Oak 8" Jacksonville,FL 32246
6. • Pine 24"
q". .\),7Oak 1. �_i / ( CA�(�Fl
\4 I• , oak J2� �`/'��Ig� I(��`'l� EARTH
Pure e0/\ F IIf Vn/V
J a„� GARDEN CENTER
MI --1
_ ,.. e,1 ri.M..VA • 1
D'i;: Oak 16,9,`' VACANT c a N r \
Lo,28
® b Parades Preserve
a Saba atm 5" Paradise Lane
11 i — �� L 0 T 2 7 l aw,K Bead%FL
LOT 29 -�� ftwiiiIl1 �oW e LOT 26 J
I i k0 Nay 23,2017
5- Deana 1"=20 , H)
I I (�,• Palm 1 i L mer ewuiarts Inc
o 11�
ICi11111174%V:
/ —1, I I On Ste Wats Storage is not Requited
I,`7�V Drama in Paradise Preserve per Rick Carper
�'�r•' r flow �
Sabal•.m 4" Lot s-C—5,601 a F.
IS, ...
Impervious area=2,584 sf. —�-1i � .€4- mum } `— zs FSI Faslvr li-
�:j lP� t
rW
�__�p
rrrr,r: \RequiH.O.A _'-- �� .` Site
Prb~+ P V Plan l
A ,1°"r-gr w.tr
H�ek COMMUNITY DEV u W ►
APPR �--=
Lib is.-- ?.S C R1/4.1-04.I sL (--Pr-.c1 ccv.--
-7/b l \ akr k St L C.N.L
I
acs
,..r,
, ..,
....,j ,......1
,--
--. Earth Works, Inc.
/ _� 12501 Beach Blvd
414 ,/\ Oak 8^ Pine 24" Jacksonville,FL 32246
\1114 4.-k
��.. jjy,\ Sall r.12"
P' r71!1
Oak si
•
I Oak A" a '& )(4Y-4 EARTH/(�Q
- as Pine 16"._....,_=,
I V ��^ r WORKS
�� J a. GARDEN CENTER
IIIIIIL
,� � � - A `
41,,,: !Oak 16.9,6 t.a za \
• 1411 VACANT b Paradise Preset°
I ® I sal. 1.5" L 0 T 2 7 N Paradse Lane
T
2 n I w�+� �I n Nlantk Beach.FL
O 1 7 .1.G Viii` �a U ` n 6
L k tai �: L 0 1 2 w
a U m DaMay 23,2017
11f—1p.n..,Orasq Scale' 1'=20' 00,k)
Cl f j i 12 S •CE+Nv�b Int
/ I.k8 1
II' 1 - i�>/ I all ( On Site Water Storage is not Required
(,��� in Paradise Preserve per Rick-Carper
_" Drai°agc a"'
IS' `.• °w , _ COMMUNITY DEVELOPMENT
Sabal'.m 4 Lot al..n 5,601 s f
•� 18, ! Impervious area=2,584 s f. �{
EASEuENL ' ' 7.5'.EA EASEMENT 1 (iJ IP . :�1 T P R O V E D
sv J/
4J _ _
—
•�.••• CEO.larcReglPer 1 Force — ---�-� Site
Per H.O.A. m a1RB�.T P vA Plan J
/T-pr_Kt p
oarek
\'`.... 1 liMil
Lib k--- �or�ti 5L 1" r:c1 cf Jia. -