Loading...
710 SAILFISH DR - ADDITION PERMIT C) ' CITY OF ATLANTIC BEACH � ss1 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 1..t011 `) INSPECTION PHONE LINE 247-5814 RESIDENTIAL ADDITION - SINGLE OR TWO FAMILY RESIDENTIAL ADDITION MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RESA17-0020 Description: addition & interior remodel Estimated Value: 253521.15 Issue Date: 1/8/2018 Expiration Date: 7/7/2018 PROPERTY ADDRESS: Address: 710 SAILFISH DR RE Number: 171209 0000 PROPERTY OWNER: Name: FLORIDA SUNRISE PROPERTIES LLC Address: P 0 BOX 1872 PONTE VEDRA BEACH, FL 32004-1372 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JADE BLUE SKY CONSTRUCTION INC Address: 2 VIEJO ST QA WILLIAM K MORTON ST.AUGUSTINE, FL 32095 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. iit` J Permit Conditions • s.) "" City of Atlantic Beach r;;, Permit Number: RESA17-0020 Description:addition&interior remodel Applied: 11/21/2017 Approved: 1/5/2018 Site Address:710 SAILFISH DR Issued: 1/8/2018 Finaled: City,State Zip Code:Atlantic Beach, Fl 32233 Status: ISSUED Applicant: <NONE> Parent Permit: Owner: FLORIDA SUNRISE PROPERTIES LLC Parent Project: Contractor:<NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 11/28/2017 EROSION CONTROL INSTALLATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: 1 Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(247- 5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 2 11/28/2017 ON SITE RUNOFF INFORMATIONAL , PUBLIC WORKS Scott Williams Notes: lAll runoff must remain on-site during construction. 3 11/28/2017 POST CONSTRUCTION TOPO SURVEY INFORMATIONAL PUBLIC WORKS Scott Williams •Notes: If on-site storage is required,a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. 4 11/28/2017 ROLL OFF CONTAINER INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,ShapeII's,Inc.,Republic Services). Container cannot be placed on City right-of-way. 5 11/28/2017 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. / . Printed: Monday,08 January,2018 1 of 2 • *jiPermit Conditions r)ler City of Atlantic Beach r n c) 6 11/28/2017 RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site. Cannot raise lot elevation. 7 11/28/2017 TOPO SURVEY INFORMATIONAL PUBLIC WORKS Scott Williams Notes: ,Must provide a topographic(TOPO)survey with water retention for final C.O. Inspection. Printed: Monday,08 January,2018 2 of 2 rs)..a,y J City of Atlantic Beach APPLICATION NUMBER s 4,, Building Department (To be assigned by the Building Department.) �`� 800 Seminole Road "'""-'='- ' Atlantic Beach, Florida 32233-5445 - &S �UC7c�` 0 V Y Phone (904)247-5826 • Fax(904) 247-5845 I ` -�%�„1'�- v E-mail: building-dept@coab.us Date routed: tt 1) t `I City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 ( 0 SC,Ik \-RS '\ ( C • De artment review required Ye No uildin Applicant: 3(A&L ,LI.t_S\-y 0S— ) la nn &Zoning a Tree Administrate Project: Ul(,-L�1711 �- n \O-( cL4nOck6 ublic Works Public tilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [-proved. Denied. Not applicable (Circle one.) Comments: BUILDIN PLANNING &ZONINGPV1- Date: II-3o-l7 Reviewed by: TREE ADMIN. Second Review: Approved as revised. Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: //1 Date: A? -g-/7 FIRE SERVICES Third Review: Approved as revised. ❑Denied. I INot applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application onOUpdated 515/17 , lli , �F City of Atlantic Beach 1 © ! V�, FACE COPY eminole Road, Atlantic Beach, FL 32233 D ' -9319 Phone: (904) 247-5826 Fax: (904) 247-5845 NOV 21 2017 Job Address: 7/0 59/4 / 92 t 4rL /30H Fe_ 3233 Permit Number' (_cin(l- cob Legal Description£07 Z', &14 rj Ar-q#76. R9erns RE# /71 ZC CX1/Z. Valuation of Work(Replacement Cost)$I' ctZ) Heated/Cooled SF/ 'q'. 7 Non-Heated/Cooled &c:).G • Class of Work(Circle one): NeAdditio Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residentia • If an existing structure, is a fire sprinkler system installed?(Circle one): Yes CD N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Wt Ce._ /woc2/az SA9cC- ,ipj t f 2/ Nr;w PaJC/dw/IZ 5Mre- — Florida Product Approval# for multiple products use product approval form Property Owner Information Name:R X.9- Svr/,C/5C- gig /47(s GGC Address: ?G• jd'e ff72- City /7 r vie/gel- FL 52.71 State Zip 3 c-. Phone 1O'- 7/4, 1538 E-Mail a/Av t 7 e cost-s) at7 Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) 6O/17t. if- AX449/G Contractor Information Name of Company: -1.406 / vim SY Cvw412o'Cr6/4/ Qualifying Agent:W/Cc/4#14 fkagIVAI Address 2- 1/6Jo 5T/ City S7 41/6-- State FL Zip 32. 647` Office Phone g -4414 Job Site/Contact Number q0(1 tac• q0/cI State Certification/Registration#GG-C 14506`/70' E-mail dive/ Lve--SkyCox/4i t4 /4c/C.CaP11 Architect Name& Phone#-1-001 MCCOMc/=t1. qpy -711 - `is'oU Engineer's Name& Phone#Lov '%bMIG,v t"cdc '!o¢ 242—ago$ Workers Compensation E6T_RL. Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAI URE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWI FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBT A IP' INAN���, C/ SULT WITH Y• - ' ENDER OR AN ATTORNEY BEFORE REC• ' ' G YO • OT V OF CO CEMENT. of Owner or Agent) (Signature g ) (Signature of Contractor) (including contractor) Signed an. swo n to(or affirmed)before me this a ) day of Signed and sworn to(or affirmed) before me this , 14-clay of NDOLti e 1'} , by Way 1/4 A\1Q( 1/4)t) ctk• ttbspe s er- , 9.011 , by (11,W‘0,3/4•44.1 NkorNiun 1, 46.AA it 41 (Si ture of Notary) ;a;w7•• ' GRACE WOWature a Notary) 'g�,�, MY COMMISSION#GG 042989 EYJENNIFER JOHNSTON 'moi '' • EXPIRES:October 27,2020 `' :�: MY COMMISSION#GG 042984 ';• FeF ,,?: Bonded Thru Notary Public Underwriters '"�i• EXPIRES:October 27.2020 [ ] Personally Known OR �'.:%���'P• •,•o? ,.q,, Bonded TtwNotary Public Underwnters [ ] Personally Known OR Produced Identification - -' �•] [—produced Identification C Q� Type of Identification: F (Di e f+J f r . `L P-n.St Type of Identification: L-V(.\ cJ Lt�NJ� CITY OF ATLANTIC BEACH :J � ,J•g1 800 Seminole Road rhs4 _ - 9 Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS 17 Date ///30/20/7 Revision to Permit Corrections to Comments X Permit# NSA- L 2-0 Project Address 7/ 0 /(_ T.-7V/ ,2 Contractor/Contact Name GG/CC//94l /ytoiTC J c; /SG C)C- SIci CC 7/Zc-C/lam Phone QT ^ 4/U19 Email ci/Wcf3LvE S y cc-fS7-xex7/oA/ Description of Proposed Revision/Corrections: Revision Review Fee Due $_O. 00 -(PE p/$ -c(0,-<_- /WO ✓IJ9077c-/Z t ciio/2/114770J g'Qc-,/,4267: , v/24t C S 4w/) Zvi' /w- Ccs co i<. Additional Increase in Building Value $ Additional S.F. ,C2– By signing below,I CC/ fr1 0470/Z affirm the Revision is inclusive of the proposed changes. / (printed name) Z(/ II/30 of C•ntrac • • :ent(Coni . tor must sign if increase in valuation) Date (Office Use Only) Approved ,X Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: Buildin /'Yt �._ anninq & Zoning Reviewed By Tree Administrator lic Wor ublic Utilities) i; " Y'/7 Public Safety Date Fire Services OFFICE COPY 1 IA rye Gk'rE :r :,..„t ' . _r�� CITY OF ATLANTIC BEACH OFFICE COPY DEPARTMENT OF PUBLIC WORKS t; 1200 Sandpiper Lane �' Atlantic Beach,FL 32233-4318 1:. ; TELEPHONE:(904)247-5834 y') l•� FAX:(904)247-5843 / www.coah.us ..1 r). -Jt)f CONTRACTOR: DATE: 11-28-17 Jade Blue Sky Construction PERMIT# RESA17-0020 2 Viejo Street ADDRESS: 710 Sailfish Drive St. Augustine, FL 32084 Atlantic Beach, FL 32233 Email: jadeblueskyconst@aol.com PERMIT APPLICATION FOR ADDITION AND INTERIOR REMODEL Your permit application has been denied by the Public Works Department for the reasons listed below. Please submit this information at your earliest convenience in order for us to approve your application. If you have any questions, please contact Scott Williams, Public Works Director at 904-247-5834 or email swilliams@coab.us. PUBLIC WORKS CORRECTION ITEMS: (Submit the following information to the Public Works Department) .7• Provide impervious surface calculations for entire lot (existing and post construction). /• Section 24-66(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 400 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-66(b). iv#4• Provide a pre-construction topographic survey prepared by a Florida Licensed Professional Land Surveyor, showing 1' contours. yr Provide a detailed plan of water retention area and how water runoff gets to water retention areas and then to street. • Provide detailed plans showing proposed water retention. PUBLIC WORKS CONDITIONS OF APPROVAL: (The following comments will be printed on your permit as Conditions of Approval) • Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (247-5814) to request an inspection from Public Works for Erosion and Sediment Control Inspection prior to start of construction. • All runoff must remain on-site during construction. • If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. • Roll off container company must be on City approved list (Advanced Disposal, Realco Recycling, Shapell's Inc., Republic Services). Container cannot be placed on City right-of-way. • Full right-of-way restoration, including sod, is required. • All runoff must remain on-site. Cannot raise lot elevation. • Must provide a topographic (TOPO) survey with water retention for final C.O. Inspection. cc: Toni Gindlesperger, Building Department Jennifer Johnston, Building Department Lot coverage calculations for 710 Sailfish Dr.Atlantic Beach Existing: OFFICE COP Y Lot 93x80.65 = 7500 House 39x24.7= 963 Carport 24x10.6= 254 Porch 11.8x10 = 118 Concrete 18x10= 180 Driveway 29.2x8 =234 Total coverage 1749 23% New addition: West addition 803 East addition 546 Breezway/front porch 146 Additional driveway 160 Total new coverage 1656 Total proposed lot coverage 3405 45% Afe . b. ,vvse 6,014c e Z. GvTfe/a ``j/1"1- 'Al,, OFFICE COPY rc R,-71wq'drd A'-"#41 3, Rvn/o £44'-4, f24,n/ ry cr 9> LOT 7 LOT 8 cn N85°20'02"W 80.65' r 'E 0 oi — , .! / A L-UJ cn NO IDENTIFICATION I �– 10'EASEMENT FOR DRAINAGE&UTILITIES - ,Z•0 NOI5ENTIFICATION FOUND 1/2'IRON PIPE /� 1 FOUND 10 IRON PIP ,ZO/ 1 1 j 3NIl Ol 33N33 I I I j 20'B.R.L. BY CITY --------------------------- I CO I �• `- f_ • ? A I ref ° ."'' co j W • O . I-! J r I m CD j I °' CO I 03 I �i ,I, - ! o o o w ni n I p I 1111 . c, I I • j I I I m i I i I I I 1 ° DOauA/5P � 4 j i ! i t1 TU wnlo I j i • j 1 i /2£G?) ; I i j ! i I j 1 r� i .1. A.,8s'o 25'B ! 01 ° ° 20'B.R.L. ° ° - I BY CITY j i 24x2 ! ! i?Er ,I/7/0A/ (TY, i j NEW EXISTING CONCRETE CONCRETEi I DRIVE DRIVE &a,s• - LB#6645 i 1I SET IRON PIF - DURDEN LB.#6f FOUND 1/2"IRON PIPE S'1'iil ,00'Z8 S85°20'02"E 80.65 eE'vNa r" TU sT SAILFISH DRIVE 60'RIGHT-OF-WAY SITE PLAN SCALE 1"=10'-0" ;.1::\;'i.;,,, OFFICE COPY !..;1 ' ,, Comp. By: SRW -' Date: 11/28/2017 a Public Works Department City of Atlantic Beach Permit No: RESA17-0020 Address: 710 Sailfish Drive Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning,Subdivsion,and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area(A) = 7,500 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft2) "C" Wtd "C" Impervious 1,749 7,500 1.00 0.23 Pervious 5,751 7,500 0.20 0.15 Runoff Coefficient(C)= 0.39 Runoff Volume V= 0.39 x 7,500 x 9.3 / 12 V= 2,247 ft3 Postdevelopment Runoff Volume: Lot Area(A) = 7,500 ft2 Runoff Coefficient ' Area Lot Area Description (ft2) (ft) "C" Wtd "C" Impervious 3,462 7,500 1.00 0.46 %ISA= 46.2% Pervious 4,038 7,500 0.20 0.11 Runoff Coefficient(C)= 0.57 Runoff Volume V= 0.57 x 7,500 x 9.3 / 12 V= 3,309 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume-Predevelopment Runoff Volume DV= 3,309 - 2,247 DV= 1,062 ft3 Retention MASTER WATER RETENTION 11/28/2017 VYrtg 4r` CITY OF ATLANTIC BEACH 800 Seminole Roadach Florida 32233 tt Atlantic Be OFFICE COPY yrs :. REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date/Z iI Revision to Issued Permit Corrections to Comments Permit# le&S/417-op?d Project Address 71 0 , \ (L Contractor/Contact Name ,` l� _ �)-k- - _ ` 4.2 •--- 1l Phone 04 fb& -4Q ( 1 Email cc 1\ o7 cotit, A . iJ r a Description of Proposed Revision/Corrections: Permit Fee II e $ 5-0 00 ......v®vet -4 .�7C i ` - -1 C7 cp` `°) cam' .—mel' .-3 libik Additional Increase inB ng Value $ 1000 Additional S.F. <Z.:SID V:)".. By signing bel. • , Ajij `i0' A 3lel/ h i, affirm the Revision is inclusive of the proposed changes. A 6„Fir (printed name) 12/—% 7 Signal. e of' a i .ctor/Agent( oo—st sign if increase in valuation) Date iir (Office Use Only) Approved x Denied Not Applicable to Department Revision/Plan Review Comments Pen it 4 3 POA IF 2c)Y> /riga vex / • p h c c' ,2 S -/c) 10-e /orZ14r/-up t p,r -P- -L. Department Review Required: _ :ui .ma - ..nin• : Zoning R wed By Tree Administrator Public Works Public Utilities / 3-c20/ s-- Public Public Safety Date Fire Services OFFICE COP' AFFIDAVIT FOR ATTACHING A NEW STRUCTURE TO AN EXISTING STRUCTURE TO: Building Inspection Department, City of Atlantic Beach,800 Seminole Road Home Owner: f /aL) Su 'sH� -/e S' L L C Name PG. 73c. /072 Street Address t2.4 52.6c34/.-/372_ City. State and Zip Code Contractor: k/C( ,.til &kW p Permit Number /&S)7 l ? 0 9- 0 As the Contractor for the proposed new structure located at the above address,I have personally viewed with the above named home owner those portions of the existing structure on which portions of the proposed new structure are to be attached for structural support.I am confident that the drawings and details included with this permit application depict the existing conditions of the host structure,and the members of the existing structure upon which the new structure are to be attached are sound with no rot or deterioration. The home owner has been advised by me that,in my best judgment based on experience and knowledge of structural adequacy,the members of the existing structure upon which the new structure are to be attached are sound with no rot or deterioration and will support all structural loads and forces imposed on them.By signing below,I hereby declare that I will hold the City of Atlantic Beach harmless and release it from any responsibility and liability for any adverse consequences or failures resulting from this work, and further that I will not initiate,execute or enjoin any legal action against the City of Atlantic Beach for such consequences or failures. A copy of this document will be recorded as an official record with the Building Inspection Department permit history so that any and all future buyers/owners of this property may be made aware of the status of ork performed on this structure. Signed (/( Date // /A i / 20/7 Before me this day of ‘ ,r. r )-(_) In the County of Duval, State of Florida,has personally appeared 4 WI 4" J C' herein by himself/herselfGG Affirms all statements and declarations herein are true and accurate. s� = GRACE MAC MY coMlulsslonl,r cc oazses ^•r EXPIRES:October 27.2020 'h.$.;1;°0• Bonded Thu Notary Pubre --lindens/niers------- No Public at Large, State ofo, County of Vrak Personally Known or Produced Identification ID Type ft.-D/V Z\C2.rti2, F:building/affidavit for attaching a new structure to an existing structure.docx 7/21/09 �L��; City of Atlantic Beach APPLICATION NUMBER i r Building Department (To be assigned by the Building Department.) J ' tla SeminolecRoad {� &S � 11 'U�a 0 K,-,,,,_ �� Atlantic Beach, Florida 32233-5445 I`- (� � Phone(904)247-5826 • Fax(904)247-5845 U (� t l� -'•:!,01119 -- E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 ( 0 Sa't \4 Sal Q f , De artment review required Yes No Buildin Applicant: 3Gat_ t1a t S(-t_i C lS1 G nning &Zoning Tree Administrator Project: d&t_‘ D11 d- t 1-W2-6 c 11- n ) 6ublic Works Public tilitie) Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: I 'Approved. Denied. ['Not applicable (Circle one.) Comments: Heat',Al- 1 5 L)� S BUILDING ./ h `� 5e4--i. ��5� vC Vey J ���O��S►, t,S PLANNING &ZONING Reviewed by/g--- Date: if—icl--1 -7 TREE ADMIN. Second Review: ❑Approved as revised. gbenied. ❑Not applicable PUBLIC WORKS Comments: 2e-fo Ad d s aiJeXA‘-:7 s PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: 7- ..-- Date: FIRE SERVICES Third Review: ZApproved as revised. ❑Denied. ['Not applicable Comments: Reviewed by: ✓�� Date: i{—3 Revised 05/19/2017 -5=-V.1 -r CITY OF ATLANTIC BEACH S� 800 Seminole Road �� Atlantic Beach,Florida 32233 A.4 om9' REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date !//' 0/2017 Revision to Permit Corrections to Comments x Permit# RE.Sf r7—CO Zt Project Address 7/ 0 f/( F€S/`j /Z_ Contractor/Contact Name GG/CC//96/ frIo/7 -' JAZ /3L C.C- Sk-'' (ciPi-c 712 -C gOA/ Phone cls{ t - got'? Email Jr4/1 C&vE Sic/ av/S%/1-4/C T/oA/ Description of Proposed Revision/Corrections: Revision Review Fee Due $ P/Zekr,'E p/b'?aGSlov-.- /3-/ /(7 /7 7/77c 4 ,l j 1•-/Fo/2"I//77c. . ; "-'4,,bee`� ?4/6/4 c GC.eetx S //v,-/.) 2c //tit= Ccisvi/N 8---A„%r- Additional Increase in Building Value $ - Additional S.F. Q- By signing below,I «/ f c.vz-70/t" affirm the Revision is inclusive of the proposed changes. (printed name) yy / llr3JZO Signature of C•ntrac • ' tent(Con - tor must sign if increase in valuation) Date (Office Use Only) Approved Denied / Not Applicable to Department Revision/Plan Review Comments Fr(74,, -5-eet",i 6.7c 4 I OV CC c-n ,r Department Review Required: / Bui cin /� / i�"�Z-- ,_-:?...An ming & Zoning, Reviewed By Tree Administrator Frublic Worlds r �� / V-1 ublic Utilities / 7 Public Safety Date Fire Services ZONING REVIEW COMMENTS City of Atlantic Beach Community Development Department 14, 800 Seminole Road Atlantic Beach,Florida 32233-5445 ;.,J rJ 40;i19'1" Date: 11/29/2017 Permit: RESA17-0020 Applicant: Jade Blue Sky Construction Review: ZONING Address: 2 Vieso St,St.Augustine FL Site Address:710 SAILFISH DR Phone: 904-806-4019 RE#: 171209 0000 Email: jadeblueskyconst@aol.com Correction Comments 1.Survey:Section 24-67(c)requires a certified survey.Please provide a certified survey. ✓l. Setbacks: Section 24-67(c) requires a site plan showing setbacks. Please provide a site plan showing setbacks from all new elements to property lines. A.Structural Projections:Section 24-83(b)limits structural projections,such as roof overhangs,to 24 inches in side yard setbacks and 48 inches into front and rear yard setbacks. Please provide the roof overhang dimensions. 1/4.Height:Section 24-17 requires height to be measured from grade to the highest point of a buildings roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height from grade on plans. Informational Comments Brian Broedell Planner ,• 1...A1.17?4, 0: s CITY OF ATLANTIC BEACH 800 Seminole Road . i—? Atlantic Beach,Florida 32233 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date l 2 // Revision to Issued Permit Corrections to Comments Permit# Project Address 7 1 0 . e.,\-- ( b� . P Contractor/Contact Name LA0 --1; CO ` ` \11 Phone Q(9 Cf t i 4Q ( Email L 3 \\07e , . f `• L; tu(4 -11 — ‘qZ Description of Proposed Revision/Corrections: Permit Fee Due $ e Ute. -+��C e F -ti„.....V___\ C c e to Additional Increase in B ' :ng Value $ 10®® Additional S.F. £' t l By signing bel. jai Qi Aw A/ ,Vl) f ( affirm the Revision is inclusive of the proposed changes. (printed name) Signat 1 e of' a i . .ctor/Agent(Co must sign if increase in valuation) Date BP (Office Use Only) Approved V Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: G�G --- -- ' .ronin & Zoning Reviewed By Tree Administrator Public Works f — — Public Utilities 1 e Public Safety Date Fire Services catmintior Z seral,4-cicS• 5' U, LOT 7 LOT 8 al N85°20029A/ 80.65 illilirdilla m ±:0___±_•13 1 .1.'0 ' 0.1. °I NO IDENTIFICATION ____,„----------- 1 0'EASEMENT FOR DRAINAGE&mew ---;.-- : vglisvicatipE FOUND lir IRON PIPE A ,TO 3NI1 01 g i 30N33 -"isCN., i N 20' B.R.L. BY CITY 1 -4• I -4 Z cn • is!• 1 Kik -----------, ili 4t, 5?. i co, . . 03 co tc2 (.3 . (P. ! ;721 . cn i-- tricl c9. j i • i CV i -<j IN , Co, . , I -s 02 (.0 54 r- co 0 i i I I c2 o o P i o c• • a Illt L -1- 1.) i 1-rp.i. 21 cn i i Zo j 1111 IF I 1- A• • i 1 .1 1 i Oil eriPik14- I. i .•,-- i , ,,•• / • , 1 , 0 1 • .;-if3lt7L- 1, , _flji ....._ ,_______,Iiii-i-, i i i Pk '1 1.04 sc.° 25'B.R.L. I : r•I : iP 1 i 1. . 20'B.R.L. . - i --6VtifY-.. I i 1 i a i i NEW EXISTING CONCRETE CONCRETE d t 0 0 i i _ DRE DRIVE , oteT Le iseeAs j cNest:IT_ .e.#6696 FOUND 1/2"IRON PIPE: , 0 1,.., : SET 1/2'IRON PIPE .ST Zi3 ., 585°2002E 80.6 StY-7---- 00\11 t., SAILFISH DRIVE 60RIGHT-OF-WAY S IT___5_1.-31-ANI SCALE 1"=10'-0" •i.:� .,-.4.,, City of Atlantic Beach APPLICATION NUMBER 4S r-iii " , Building Department (To be assigned by the Building Department.) `• 800 Seminole Road NOV 2 2 2017 �S /� l' ��j��, '',\‘:„....,._ t -~ Atlantic Beach, Florida 32233-5445 1 Phone (904)247-5826 • Fax(904)247-5845 u t .\l� -.E,o;;lyE-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 10 Sc -k \- v\ 0-c . De artment review required Yes No y Buildin Applicant: 3C(kaki_ tIa LS� 0 L( - SAJA_C_Ai) fanning &Zoning 1 I Tree Administrate Project: (.(,-i*Dll `. t 1 -0 Of cLsnbC 'ublicWorks Public utilities j Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: nApproved. %enied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b Date:k-47477_,, TREE ADMIN. Second Review: /proved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed b : Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 CITY OF ATLANTIC BEACH I_ �'� 800 Seminole Road DEC 0 4 2017 Atlantic Beach,Florida 32233 REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COMMENTS Date ///30/2017 Revision to Permit Corrections to Continents X Permit#RgSA . - (]OZ O Project Address 7/ 0 S,l/( riStf ,7/a Contractor/Contact Name GG/CC fflfrf j(a�CYt-, C�ckt-g T/1-c-c/lam Phone q t4 4/0/ci Email d/W6-f3G 4/ c7 y cc/w-S7?z,c//0A/ Description of Proposed Revision/Corrections: Revision Review Fee Due$ pwv,wc p/s1Fo-Sf /9vs//2 Apo 77(4-/ 1/ ''o/2rti// 7c -, ; 3 j 6-'Q,,IRe. i3( it/64i c USX S /iv--/) z itis= Cc „pi Additional Increase in Building Value $ -t Additional S.F. at:Z2— By signing below, I ‘C/ CC(#14/7 n 047O N affirm the Revision is inclusive of the proposed changes. (printed name) Z(../ / 11/30 /7 Signature of C•ntrac • lent(Coni : tor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments R Department Review Required: �Buildin _ � nnin &Zoning Reviewe y Tree Administrator 40:041riMm. 'ublic Utilitie /2 777Public Safe Fire Services C Comp. By: SRW Date: 11/28/2017 ! ,� Public Works Department City of Atlantic Beach Permit No: RESA17-0020 Address: 710 Sailfish Drive Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion,and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area(A) = 7,500 ft2 Runoff Coefficient Area Lot Area Description (ft) (ft) "C" Wtd "C" Impervious 1,749 7,500 1.00 0.23 Pervious 5,751 7,500 0.20 0.15 Runoff Coefficient(C)= 0.39 Runoff Volume V= 0.39 x 7,500 x 9.3 / 12 V= 2,247 ft3 Postdevelopment Runoff Volume: Lot Area(A) = 7,500 ft2 Runoff Coefficient Area Lot Area Descriptionft2) (ft2) "C" Wtd "C" Impervious ,462 7,500 1.00 0.46 %ISA= 46.2% Pervious 4,038 7,500 0.20 0.11 Runoff Coefficient(C)= 0.57 Runoff Volume V= 0.57 x 7,500 x 9.3 / 12 V= 3,309 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume- Predevelopment Runoff Volume DV= 3,309 - 2,247 DV= 1,062 ft3 Retention MASTER WATER RETENTION 11/28/2017 Comp. By: SRW Date: 11/28/2017 st Public Works Department City of Atlantic Beach Permit No: RESA17-0020 Address: 710 Sailfish Drive Provided Storage: Elevation Area Storage (ft) (ft) (ft) 7.5 504 0 BOTTOM 28 X 18 8.0 600 276 TOB 30 X 20 Elevation Area Storage (ft) (ft) (ft3) 0 BOTTOM 0 TOB Elevation Area Storage (ft) (ft) (ft3) 0 BOTTOM 0 TOB Inground storage=A*d*pf A=Area= 600.0 d=depth to ESHWT= 4.5 pf= pore factor= 0.3 Inground Storage= 810.0 ft3 Required Treatment Volume= 1,062 ft3 Supplied Treatment Volume = 1,086 ft3 Retention MASTER WATER RETENTION 11/28/2017 MAP SHOWING BOUNDARY SURVEY OF: LOT 24, BLOCK 5, ROYAL PALMS UNIT ONE, AS RECORDED IN PLAT BOOK 30, PAGES 60 AND 60A OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA SAILFISH DRIVE 60' RIGHT—OF—WAY ?C 27c)t r WO P 2 I-4 r_/-�7ioA/ 0 1/2"IRON PIPE ' ' S852002»E 80.65' 62.00• N.T.S. 4 je//L/V'- SET 1/2"IRON PIPE DURDEN LB. /6696 — 82.00• N.T.S. a N I i FOUND 1/2"IRON PIPE FDUND l/2• I LB/6645 ND IDENTIFICATION 170tvN S?Qvr t • !, , , t i --= .4 ,, K' 11, •' 1-STORYEIE BLOCK CONCRRESIDENCEkI" O No. 770 4 N -, a , n N '...". k wiliaSiLi- 0 O 271 t J MI 24.7' 0) <t Ar7 O G'-4-72 Z • NO IDENAFlCATTON 1.'I •.2 aa,. I/f/•7/G/2 —L-- 0.7' 1 D'EASEMENT FOR DRAINAGE R UNL07ES— ' .—1 ,.2. rr '.2 -r7)C/L- - — IV85'20'02 (f/ , I, FOUND 1/2"IRON PIPE 80_65 = 19 IDENTIFICATION LOT B \A' L 0 T 7 \\ \ \ \ NOTES THIS PROPERTY UES IN FLOOD ZONE X PER FLOOD INSURANCE RATE AMP(FIRM),DUVAL COUNTY,COMMUNITY No. 120075, AMP/PANEL No. 12031C-0408-H,REVISED JUNE 5,2015 BEARINGS BASED ON THE SOU1N RIGHT-OF-WAY LINE OF SAILFISH DRIVE AS BEING N 85'20'02'W 25'BOLDING RESTRICTION LINE(BR.L)BY PUT N.T.S.DENOTES NOT TO SCALE ALL LOIS SHOWN HEREON LIE WITHIN BLOCK 5 -X—DENOTES 4'CHAIN LINK FENCE EXCEPT AS NOTED CERTIFIED TO: THERE MAY BE AOOIrroNM.RESIRICTONS THAT ARE NOT SHOW ON FLORIDA SUNRISE PROPERTIES, LLC THIS SURVEY TINT MAY BE FOUND IN THE PUBLIC RECORDS OF DUVAL COUNTY,FLORIDA, I hereby certify that this survey meets the lminimum technical standards as set forth by A DURDEN i the Florida Board of Land Surveyors, pursuant to ISURSection 472.027 Florida Statutes and Chapter VEYING M , INC. I 5J17 Florida Admini ive Cod 1825-8 3RDAND DsNORTH JACKSONVILLE BEACH, FLORIDA 32250 ' I/ 1 (9LLIC4) 853-6822 ENS D BUSINESS xNO. 6696 853-6825I FLORIDA REGISTERED SURVEYOR No.4707 H.BRUCE DURDEN,Jr. 17RVEYIRS NOT I THE SURVEY HEREON WAS MADE RTH(XfT THE BENEFIT OF ABSTRACT OR SEARCH OF TITLE AND SIGNED JANUARY 16. 2017 THEREFORE THE UNDERSIGNED AND DURDEN SURVEYING AND MAPPING.INC.,MAKE NO CERTIFICATIONS REGARDING INFORMATION SHOWN OR NOT SHOWN HEREON PERUIWNG TO EASEMENTS CLANS OF SCALE: 1" = 20' EASEMENTS,RIGHTS-OF-WAY,SETBACK LINES,OVERLAPS,BOUNDARY UNE DISPUTES,AGREEBIEVIS• RESIGNATIONS OR OTHER SMEAR MATTERS WHICH MAY APPEAR IN THE ABSTRACT OR SEARCH OF ME. WORK ORDER NUMBER: 17015 B-9003 THIS SURVEY NOT VALID UNLESS THIS PRAT IS EMBOSSED WON THE SEAL OF THE ABOVE SIGNED. City of Atlantic Beach APPLICATION NUMBER (< " \ Building Department (To be assigned by the Building Department.) s 800 Seminole Road NOV {, 2 2017 t r ri —Uoa c v Atlantic Beach, Florida 32233-5445 (�J Phone(904)247-5826 • Fax(904)247-5845 �t (� t,l-} P.(05110. E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 ( 0 Sup \1�� i\ 0-c , Dement review required Yes No ' Building Applicant: 36i ! ` Q k,i t S (•-y C S1 C-: lanning &Zoning Tree Adminis ra or Project: eRd d-�'--\-;D11 `: t 11 \ C 1,.__en l9(1.6 'ublic Works Public Itilities__> Public Safety Fire Services Review fee $ Dept Signature , Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: I",/- �te: It728)/? TREE ADMIN. Second Review: nApproved as revised. Denied. ❑Not applicable P WO ments: UBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ^ ei. , CITY OF ATLANTIC BEACH � 800 Seminole Road Atlantic Beach,Florida 32233 DEC 0 4 2017 REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COMMENTS 0/20/? )< Permit# �� A 1-7-00 .C.. Date /! Revision to Permit Corrections to Comments Project Address 7/ 0 4/c. r FSf Contractor/Contact Name GG/CC//9SZ? /t1OtC (/,J fk,Com / cc , ?a/ Phone ''( t " 4/0(c% Email c)' /9L t/ sjc j/ Cc/t/c7/2 crc f/o/t/ Description of Proposed Revision/Corrections: Revision Review Fee Due $ ?MK/7C p($? (/cwc. /314//2 40077w-/rt ltiFo/2114717-7 "-'Q4.3/42G5i f c l fX.✓L/c S ,4w/) Zc /,v- CGr17/71 FA-- Additional Increase in Building Value $ -' Additional S.F. .C2-- By signing below,I 44/ <</M-Vi n o,27O/+i affirm the Revision is inclusive of the proposed changes. (printed name) Z(-/ ///3d/2-0T7 Signature of C ntract(Con . tor must sign if increase in valuation) Date (Office Use Only) Approved v Denied Not Applicable to Department Revision/Plan Review Comments 0.5-1c- / 77 �W--eV4L— Department Review Required: / Ouildin nnin & Zoning Reviewed By Tree Administrator •u•lic Wor public Utilities_ • l, .�(� 1271/ 1Y Public Safety /Z-to/7 Date Fire Services COM/)1E )7 L y LOT 7 LOT 8 al N85°20'02"W 80.65' ,1•0 QbE�NT1 10'EASEMENT FOR DRAINAGE&Ainille" . AIIIIIrdlln . .z : Fou 72FICAIRON°NPIPE I NO IDENTIFICATION FOUND 1@'IRON PIPE i Z. 1 3NI1 Ol Ni I — 30N33 tf? N tt I II20'B.R.L. BY CITY .--------------- ----- z cri N I 41I ■Ik� A I 03 ° ° �� m cWo •I �iF__. _ 'r m of tn j 1 .� c 11 0 co t7! `_ O w I 1 ° N ! I I I n N i 161111 IF rillibt i i i all , SPr?i/C14" . • s°9` s ' L -� ii -- --. j i ...- i L'OJj`,4E'0 25' B.R.L._ 1 •---------------- --------t.----- BY PLAT --------- - j - i ° _ 20' B.R.L. ° ._._._._._._.- ° BY CITY j I j 'a I j b I jNEW EXISTING N 0 i CONCRETE CONCRETE � j DRIVE DRIVE j DURDEN L.B.N6698 • SET tf2'IRON PIPE LB 2 IRON .._..�.._..—.._.._..—.._.. FOUND 1f2• PIPE! _ _ ""— .Si. ,One .. J S85°20'02"E 80.• tl SAILFISH DRIVE 60'RIGHT-OF-WAY SITE PLAN SCALE 1•=10'-0" Opy � � o0vA �02v 0 FF��EC L EA 7 TLANTI�B �S� � j TgE CITY OFA pernitt # �' ORATION SHEET F OR ���lctacy•coNr 0,0,o ok Pitt V 'Z �,a Oto ve.4 0).51' to �j<� oration ��� rovide the I be listeata�teg �o•• C �rS N— T> n +� ✓P�' Code Rule 9B-72,PleaesctPot the permoancts• I�°�' �oca1# �o nistrative constructlOn PrO� ble listed P ✓Pr,� ,a to 553.842 and Florida Admi o f e applica applicable to the building e Is, Us r sreonents listed below as duct approval number fOry nation of yob f�0 pplier if you do not know the p Ltn' $��f�°0A�oval ma be obtained at:www.tloridabuildln_•orProduct Deseption 0000,07z A ',.gory/Subcategory . EXTERIOR DOORS o d�" s�� p 111111111111111111111111111111110010 1. Swinging hl�I���`�c 2. Sliding 3. Sectional 4. Roll up 1111 II _I I I 11111111 I I 111 I I I W III I I 1.I I.I I.01 1 11.0. -111°10, 5. AutomaticI I I I I I 111.01 ill 'i•i . 0 1 1 p..IO • 6. Other millI__ B. WINDOWS �N 1,- ,z„,,, 1. Single hung II 11111 001111110.0001,1111. 2. Horizontal slider 3. Casement 4. Double hung 5.Fixed 6.Awning Millilliii ..11 7.Pass-through 8. Projected 9. Mullion WI ill 1111 1111111111111011100111111 10. Windbreaker 11. Dual action IIIIIIIIIIIIIIII OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA Project Name: 7i a 5/4/ fly j>/2('(/.'"' , — 14,d Jif L Permit # / S4 /7--002 v Project Address: 7/d 6"91 c ,Pi /9-7z /S ri/ As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide roduct a proval may be obtained at: w-ww.floridabuildin .or . Category/Subcategory I Manufacturer Product Description I Limitation of Use _ State# Local# A. EXTERIOR DOORS 1. Swinging Ng/Cc/4c,rr g-)47 pdd 4 P--8ZZ$.l 2. Sliding 3. Sectional 4. Roll up 5. Automatic 6. Other B. WINDOWS 1. Single hung OW.O tn.07�Kr1q� FG Veld . 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 1111r12. Other Category/Subcategory Manufacturer t Product Description Limitation of Use State# Local# C. PANEL WALL 1. Siding 1-049 v t,'P Sio/NG- /3/42 Z 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles GAF FL 1012A-12M 2. Underlayments /97 Fe- 17 Z2 3. Roofing fasteners 4.Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof W17. Other Category/Subcategory Manufacturer Product Description 1Limitation of Use State# Local# E. SHUTTERS 1. Accordion 2. Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor Sirh � 2. Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) ix)!((/Pfri 0/Z/gr— (Signature) Company Name: Pin"- 1;1-1/C x/ COP TT(1,c)C7l3 tJ Mailing Address: Z- k//E.IO ST/ZW( City: ST . State: EL Zip Code: 32-0 Telephone Number: (609 ) d/ t Fax Number: ( ) Cell Phone Number: ( ) E-mail Address: .1ACIFRL`165i�/ C°1(-'5/ #1d6 8 Co MAP SHOWING BOUNDARY SURVEY OF: LOT 24, BLOCK 5, ROYAL PALMS UNIT ONE, AS RECORDED IN PLAT BOOK 30, PAGES 60 AND 60A OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA SAILFISH DRIVE 60' RIGHT—OF—WAY / IRON PIPE ?(..)27c..)1.-677- �/!'Yt P 2 L� ?/v,4/ �reo�FTCATTON y 82.00' N.rs. S85'20'02"E 80.65' �A��/tib".. SET I/2"IRON PIPE �� 1----Air DURDEN LB./6696 — B2.00' N.T.S. u n RERAR �T FOUND 1/2•IRON PIPE FOUND I/2• I - LB/6645 NO IDENTIFICATION pow,/"?e,llT` m:; I: T . r'tt• • -� .... i t Ialk -�0U�/A./ M o X 12.. . 'r• . . . N 0 24.7• .'. O . . f I 1 0 p� -STORY AtoNCR BLOCK R M1�RESIDENCE 0) • No. 71001.0--� to s• ;) N 0 7.4j i 10 ' rn `=` co o ;`? 24,r r tl, 29,2 Nt' ‘"1-/r7Z,74e __y Fou1715-1/'1.-1120 P- I NO IDENTIRC47TON I..i ''� . 10'EASEMENT FORD 1 ' '•�,� fiV /l h o.7, RIVNAGE&UIIUT/ES—��� rr 0.1' L ----N85.20'02 'W , h /, FOUND I/2"IRON PIPE '""� 80.65 = PR IDENTIFICATION 4 \ LOT 8 \4 \ LOT 7 \\ \ \ \ AIRES, THIS PROPERTY LIES IN FLOOD ZONE X PER FLOOD INSURANCE RATE ANP(FIRM),DUVAL COUNTY.COMMUNITY No. 120075, MAP/PANEL No. 1203IC-0408—H,REVISED JUNE 3,2013 BEARINGS BASED ON THE SOUTH RIGHT—OF—WAY ONE OF SAILFISH DRIVE AS BEING N&T20'02'W 25'BUILDING RESTRICTION UNE(B.R.L)BY PUT N.T.S.DENOTES NOT 70 SCALE ALL LOTS SHOWN HEREON LIE WITHIN BLOCK 5 —X—DENOTES 4'CHAIN LINK FENCE EXCEPT AS NOM CERTIFIED TO: THERE MAY BE ADDITIONAL RESTRICTIONS TEAT ARE NOT SHOW ON FLORIDA SUNRISE PROPERTIES, LLC THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OFF DINAL COUNTY,FLORIDA I hereby certify that this survey meets the A minimum technical standards as set forth by D U R DEN I the Florida Board of Land Surveyors, pursuant to I Section 472.027 Florida Statutes and Chapter ' SURVEYING AND MAPPING, INC. I 5J17 Florida Admini Iva Cod 1825-B 3RD STREET NORTH I IJACKSONVILLE BEACH, FLORIDA 32250 1 (9LICENS D B853-6U SINESS22 XNO. 6696 853-6825I FLORIDA REGISTERED SURVEYOR No.4707 It BRUCE DURDER,Jr. SLRVEYR25 NOTE THE SURVEY HEREON WAS MADE WITHOUT THE BENEFIT OF ABSTRACT OR SEARCH OF TITLE AND SIGNED JANUARY 16. 2017 THEREFORE THE UNDERSIGNED AND CAMDEN SURVEYING AND MAPPING,INC.,MAKE NO CERTIFICATIONS REGARDING INFORMATION SHOWN OR NOT SHOWN HEREON PERTAINING TO EASEMENTS CLAWS OF SCALE: 1" = 20' EASEMENTS,RIGHTS—OF—WAY,SETBACK LINES.OVERLAPS BOUNDARY LINE DISPUTES AGREEMENTS, RESERVATIONS OR OTHER SWAM MATTERS WHICH AMY APPEAR IN THE ABSTRACT OR SEARCH OF TITLE, WORK ORDER NUMBER: 17015 B-9003 THIS SURVEY NOT VALID UNLESS THIS PRINT IS EMBOSSED WITH THE SEAL OF THE ABOVE SIGNED. J. Rovse ogi4c et: &terrea Cr) APPROVED 2. Gu'rrr,-- „, 404.4 a I, A teN ili the WOO/PlitiAJ rC) AE-1-7-#4441491'd Aaii: 1 3, Rt./A/F /44 4,4, A441/4/ ro 57-4E47' F. h 9, a.-7-- . LOT 7 (7 L 0 T 8 02 N85°20'02"W 80.65' r .E0 cs2 --. i j 01 al NO IDENTIFICATION I 10'EASEMENT FOR DRAINAGE&UTILITIES z-o-zi NO/IDENTIFICATION FOUND 1/2”IRON PIPE} ------------- i FOUND 1/2"IRON PIP I 3NI1 01 i I 33Nad I I I 1 i i 20'B.R.L. BY CITY i I -4• I ;A.V• . Z W • bi jeA' 'lig- iri I G . -1= 4C2 I F(1-* o I _11 k. _ .... ,,,,, co 1 G3 03 • . co ,,- co ! CJi X. \ ,,,,,,-''-- 50 1 COI C2 i ! i...'-1 '; Ca i '''s i '‘, ....."', 7 , i-- co __< i rfi b I \ L) • 0 a ! 0 - --\ - - ri 7-4 • 0 ! -n r.) 1 \ i • m CJ1 i 1 ! Z i i . hi li i 2 1 II 1 i i i DOWA,SPovi I i i ii re) friVorie, 11 i i i ii1 I9S R5c.,?` I ---- 7 i 11 i i 1! i . ./.0-9 -.9£'0 25'B .-17.0 • ! 1 i BY CITY i 2.4 x 25 i //5Lact.: i i (TYPJ iNEW EXISTING CONCRETE CONCRETE 1 i DRIVE DRIVE L.B#6645i 1 i DURDEN L.B.#6 FOUND vr IRON PIPE f 11'1 S85 ,,4 sEr 1/2"IRON PIF °20'02"E 80.65' ----..---- ,,, 'I/ 7-- To' 5-712-err SAILFISH DRIVE 60RIGHT-OF-WAY SITE PLAN SCALE 1"=10.-0" OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Residence,710 Sailfish Dr E Builder Name: Jade Blue Sky Construction Street: 710 Sailfish Dr E Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (1465.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 764.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.0 701.60 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1891.7 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1891.70 ft2 6. Conditioned floor area above grade(ft2) 1891.69995117 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(198.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 245.92 a. U-Factor: Dbl,U=0.40 198.50 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 34.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 6.563 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems a.Electric Cap:50 gallons 8. Floor Types (1891.7 sqft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 1891.70 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 47.96 PASS Glass/Floor Area: 0.105 Total Baseline Loads: 49.98 I hereby certify that the plans and specifications covered by Review of the plans and , 0*THE sr -..., this calculation are in compliance with the Florida Energy specifications covered by this .; ::-.,V ' ..,04;' Code. Aptu,Q calculation indicates compliance =� %�„ � .- Ryan B. Ellis with the Florida Energy Code. ?'t .rnr ,�• O PREPARED BY: _ Before construction is completed DATE: 11/21/17 _ this building will be inspected for 1 CD compliance with Section 553.908 '• 4:',. bg° °_ } Florida Statutes. r r I hereby certify that this building, as designed, is in compliance �1•' •......, �� .. ; with the Florida Energy Code ,,y� %. CO- WE T¢,..*' OWNER/AGENT: BUILDING OFFICIAL: /' ' DATE: ///�1 /2cJ11 DATE: ii'3a'L7 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Residence,710 Sailfish Dr E Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1892 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Jade Blue Sky Construction Rotate Angle: 0 Street: 710 Sailfish Dr E Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT_NS FL_MAYPORT_NS 2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 Blockl 1891.699 15133.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfihID Finished Cooled Heated 1 Main 1891.7 15133.6 Yes 4 3 1 Yes Yes Yes FLOORS ✓ # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulation Main 183.2 ft 0 1891.7 ft2 ____ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2049 ft2 0 ft2 Medium 0.6 No 0.4 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1891.7 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 38 Blown 1891.7 ft2 0.11 Wood 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V # Ornt To Wall Type Space R-vaiup Ft In Ft In Area R-Value Fraction Ahcor GrariP% 1 N Exterior Concrete Block-Int Insul Main 4 24 8 192.0 ft2 0 0.170000 0 2 E Exterior Frame-Wood Main 19 7.9 8 63.2 ft2 0.05 0.170000 0 3 N Exterior Frame-Wood Main 19 20.3 8 162.4 ft2 0.05 0.170000 0 4 W Exterior Frame-Wood Main 19 47 8 376.0 ft2 0.05 0.170000 0 5 S Exterior Frame-Wood Main 19 20.3 8 162.4 ft2 0.05 0.170000 0 6 S Exterior Concrete Block-Int Insul Main 4 24.7 8 197.6 ft2 0 0.170000 0 7 E Exterior Concrete Block-Int Insul Main 4 39 8 312.0 ft2 0 0.170000 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.4 0.25 18.0 ft2 5 ft 0 in 1 ft 0 in None None 2 N 1 Vinyl Low-E Double Yes 0.4 0.25 12.0 ft2 9 ft 0 in 1 ft 0 in None None 3 N 3 Vinyl Low-E Double Yes 0.4 0.25 30.0 ft2 2 ft 0 in 1 ft 0 in None None 4 W 4 Vinyl Low-E Double Yes 0.4 0.25 45.0 ft2 2 ft 0 in 1 ft 0 in None None 5 W 4 Vinyl Low-E Double Yes 0.4 0.25 9.0 ft2 2 ft 0 in 1 ft 0 in None None 6 W 4 Vinyl Low-E Double Yes 0.4 0.25 6.0 ft2 2 ft 0 in 1 ft 0 in None None 7 S 5 Vinyl Low-E Double Yes 0.4 0.25 30.0 ft2 2 ft 0 in 1 ft 0 in None None 8 S 6 Vinyl Low-E Double Yes 0.4 0.25 6.0 ft2 2 ft 0 in 1 ft 0 in None None 9 E 7 Vinyl Low-E Double Yes 0.4 0.25 33.5 ft2 20 ft 1 in 1 ft 0 in None None 10 E 7 Vinyl Low-E Double Yes 0.4 0.25 9.0 ft2 20 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1765.6 96.93 182.29 .274 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 32.8 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 34.6 kBtu/hr 1038 cfm 0.75 1 sys#1 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 4 FORM R406-2014 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply--- ---Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 245.92 f Attic 94.5849 Default Leakage Main (Default)c(Default)c 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar AprMa X Jun X Jul X Au X Se Octt Novv Dec c Venting HeatinX Jan JanX Feb X' Mar X Apr May Jun Jul Aug Sep X Oct [XI Nov X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 710 Sailfish Dr E, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 764.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.0 701.60 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1891.70 ft2 6. Conditioned floor area(ft2) 1892 b.N/A R= ft2 7. Windows** Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.40 198.50 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Main 6 245.92 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.6 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 32.8 HSPF:8.20 Area Weighted Average Overhang Depth: 6.563 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1891.70 ft2EF:0.92 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building :. .�HE•sT9T • Construction through the above energy saving features which will be installed (or exceeded) O:••: ..;.. . .Fo'.:. in this home before final inspection. Otherwise, a new EPL Display Card will be completed ;°°, .; 's' ,:. based on installed Code compl".nt features. ; :.,.,./1 .•• i ;-e' Ao to - - ?vI.? Builder Signature: A Date: I.c9,, . : e - • * ;°�~p Address of New Home: 71 co tiR_ 't /S1-? n/'( City/FL Zip: p� :!.t,~ v5� coo wE 3223 .. . .. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 710 Sailfish Dr E Permit Number: Atlantic Beach . FL . MANDATORY REQUIREMENTS See individual code sections for full details. X 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law[Section 553.9085. Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. X R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. X R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1.as applicable to the method of construction. Where required by the code official.an approved third party shall inspect all components and verify compliance. ▪ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f).(g).or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors.fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures: 2. Dampers including exhaust,intake.makeup air. backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures: 3. Interior doors,if installed at the time of the test.shall be open: 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems.if installed at the time of the test.shall be turned off:and 6.Supply and return registers, if installed at the time of the test,shall be fully open. X R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. X R402.4.3 Fenestration air IeakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2).when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited.independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. X R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. X R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. X R403.1.3 Heat pump supplementary heat(Mandatory)Heat pumps having supplementary electric-resistance heat shall have controls that. except during defrost.prevent supplemental heat operation when the heat pump compressor can meet the heating load. X R403.2.2 Sealing(Mandator011 ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7).Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes.to be 'substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system.including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm(85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) X R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. X R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55°F(13'C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. 0 R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. X R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. X R403.4.4 Water heater efficiencies(Mandatory). X R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water heating systems to be turned off. X R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation.Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806.Test Methods for Solar Collectors.and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code. Residential or Florida Building Code. Mechanical,as applicable,or with other approved means of ventilation.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. X R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. X R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) X R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. X R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ▪ R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. X R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar ' energy source computed over an operating season. X RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights X R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. X R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3 FORM.R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Residence,710 Sailfish Dr E Builder Name: Jade Blue Sky Construction Street: 710 Sailfish Dr E Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. X Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. X Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. X Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and X Rim joists Rim joists are insulated and include an air barrier. X Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. X The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. X Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or X unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity X spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. X Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. X Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to X available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air X barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. X HVAC register boots HVAC register boots that penetrate building thermal envelope shall be X sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have X gasketed doors 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 • FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Residence,710 Sailfish Dr E Builder Name: Jade Blue Sky Construction Street: 710 Sailfish Dr E Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Design Location: FL,MAYPORT_NS Jurisdiction: 261100 Cond.Floor Area:: 1892 sq.ft. Cond.Volume: 15134 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: CFM(50): C: n: R: ELA: Single or Multi Point Test Data HOUSE PRESSURE FLOW: EgLA: 1 Pa cfm ACH: 2 Pa cfm SLA: 3 Pa cfm ACH(50) * : 4 Pa cfm * For prescriptive projects, tested leakage must be 5 Pa cfm <=7 ACH(50). For performance projects, tested 6 Pa cfm leakage must be <=the ACH(50)shown on Form R405-2014 for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing shall be conducted by either .HE ST I hereby certify that the above envelope leakage individuals as defined in Section 04 '�TF''•. performance results demonstrate compliance with Florida Energy Code requirements in 553.993(5) or(7), Florida Statutes or :�: ,". individuals licensed as set forth in ; , `�., ,.��`` accordance with Section R402.4.1.2. n" `'' Section 489.105(3)(f), (g), or(i) or an .::- — aPProved third party. A written report 0:. _ a of the results of the test shall be SIGNATURE: = f .. signed by the third party conducting ::,•,�c the test and provided to the code OD wE'I�,,•• PRINTED NAME: , BUILDING OFFICIAL: DATE: DATE: 11/21/2017 12:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 *4 Manual S Compliance Report Job: Wrlg�lt5oft Date: 11/11/17 Entire House By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville, FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.jax@gmail.com Project Information For: Residence 710 Sailfish Dr E, Atlantic Beach, FL Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 27370 Btuh Entering coil DB: 78.2°F Outdoor design WB: 77.4°F Latent gain: 4958 Btuh Entering coil WB: 64.1°F Indoor design DB: 75.0°F Total gain: 32329 Btuh Indoor RH: 50% Estimated airflow: 1153 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman Mfg. Model: GSZ140361K+ARUF37C14A Actual airflow: 1153 cfm Sensible capacity: 26988 Btuh 99% of load Latent capacity: 7612 Btuh 154% of load Total capacity: 34600 Btuh 107% of load SHR: 78% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 25051 Btuh Entering coil DB: 66.9°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman Mfg. Model: GSZ140361K+ARUF37C14A Actual airflow: 1153 cfm Output capacity: 32800 Btuh 131% of load Capacity balance: 32 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1153 cfm Output capacity: 7.2 kW 98% of load Temp. rise: 67 °F Meets are all requirements of ACCA Manual S. wri htsoft` 2017-Nov-21 0o:1ge 1 g Right-Suite®Universal 2017 17.0.17 RSU17457 Page 1 ACC ...ual J\Residence,710 Sailfish Dr E,Atl Bch.rup Calc=MJ8 Front Door faces: N Project SummaryJob: ' - wrightsoft° Date: 11/11/17 Entire House By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville, FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.jax@gmail.com Pro'ect Information For: Residence 710 Sailfish Dr E, Atlantic Beach, FL Notes: Desi• n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 Moisture difference 50 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18085 Btuh Structure 17002 Btuh Ducts 6966 Btuh Ducts 10368 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25051 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 27370 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2724 Btuh Ducts 2234 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1892 1892 Equipment latent load 4958 Btuh Volume(ft3) 15136 15136 Air changes/hour 0.46 0.20 Equipment total load 32329 Btuh Equiv.AVF (cfm) 116 50 Req. total capacity at 0.77 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN; JANITROL;AMANA DISTI... Trade GOODMAN; JANITROL;AMANA DISTI... Model GSZ140361K Cond GSZ140361K AH RI ref 7995253 Coil ARUF37C14A AH RI ref 7995253 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 24220 Btuh Heating output 32800 Btuh @ 47°F Latent cooling 10380 Btuh Temperature rise 26 °F Total cooling 34600 Btuh Actual air flow 1153 cfm Actual air flow 1153 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 32 °F Backup: Input = 7 kW, Output = 24617 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 WrigfltSOft Right-Suite®Universal 2017 17.0.17 RSU17457 2017-Nov-21 00:19:21 Page 1 liCaA ...ual AResidence,710 Sailfish Dr E,Atl Bch.rup Calc=MJ8 Front Door faces: N " Sheet 1 Bed 2 12 200 cfm Master Bed £ IC 12 x 12 10 " M 57 cfm a• x 1 s• 4 „ 7 „ Bath 2 8 ,. , ., 5 cfm ' - til! 1200 cfm _ 4 4 " 111111 Hall T ,r a �, 12 x 2 T-"-137 cfm ,23 cfbhBath 6 8 L. . ndry81cm fRoom 10 8 19 cfm 6 " 8 " 227 cfm 6.46 cfm � 272 cfm Kitchen Dining Family Room Job#: Exclusively for the use of: Scale: 1 : 75 Performed for: Page 1 Residence Cooler Bear Heat & Air LLC Right-Suite®Universal 2017 710 Sailfish Dr E 17.0.17 RSU17457 Atlantic Beach.FL 2017-Ncv-21 00:21:40 ...,710 Sailfish Dr E,Atl Bch.rup " + inrrightsoft= Duct System Summary Date: Entire House By: Exclusively for the use of: Cooler Bear Heat&Air LLC Project Information For: Residence 710 Sailfish Dr E, Atlantic Beach, FL Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/ return available pressure 0.050/ 0.050 in H2O 0.050/ 0.050 in H2O Lowest friction rate 0.088 in/100ft 0.088 in/100ft Actual air flow 1200 cfm 1200 cfm Total effective length (TEL) 114 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 2 c 1624 55 57 0.096 4.0 Ox 0 VIFx 14.5 90.0 st1 Bed 2-A h 5440 200 195 0.090 7.0 Ox 0 VIFx 21.2 90.0 st1 Dining c 1314 45 46 0.088 6.0 Ox 0 VIFx 23.6 90.0 st1 Family Room-A h 7413 272 270 0.091 8.0 Ox 0 VIFx 19.7 90.0 st1 Kitchen-A h 6194 227 225 0.091 8.0 Ox 0 VIFx 20.4 90.0 st2 Laundry c 531 16 19 0.094 4.0 Ox 0 VIFx 16.2 90.0 st2 M Bath c 656 19 23 0.094 4.0 Ox 0 VIFx 15.9 90.0 st2 Master Bed h 5329 195 192 0.097 8.0 Ox 0 VIFx 13.1 90.0 st2 . Roomlo c 2319 79 81 0.097 6.0 Ox 0 VIFx 12.6 90.0 st1 Toilet h 1017 37 36 0.090 4.0 Ox 0 VIFx 20.6 90.0 st2 WIC c 1624 55 57 0.096 4.0 Ox 0 VIFx 14.1 90.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 650 648 0.088 828 12.0 0 x 0 VinIFix st2 Peak AVF 550 552 0.090 702 12.0 0 x 0 VinIFIx Bold/italic values have been manually overridden 2017-Nov-21 00:21:21 �i�+ wrightsoft' Right-Suite®Universal 2017 17.0.17 RSU17457 Page 1 ACC ...ual D\Residence,710 Sailfish Dr E,Atl Bch.rup Calc=MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb6 Ox 0 1200 1200 0 0 0 0 Ox 0 VIFx 2017-Nov-21 00:21:21 .+ wrightsoft Right-Suitee Universal 2017 17.0.17 RSU17457 Page 2 ACcP. ...ual D\Residence, 710 Sailfish Dr E,Atl Bch.rup Calc=MJS Front Door faces: N