Loading...
1684 ATLANTIC BEACH DR - NEW HOMW PERMIT .�� '4 _- CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD 1511.. ze v ATLANTIC BEACH, FL 32233 !o;3 v%' INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0152 Description: new home construction Estimated Value: 358344.65 Issue Date: 9/26/2017 Expiration Date: 3/25/2018 PROPERTY ADDRESS: Address: 1684 ATLANTIC BEACH DR RE Number: 169505 1715 PROPERTY OWNER: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD HORSHAM, PA 19044 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: TOLL BROS.,INC Address: 250 GIBRALTAR RD STEVEN R MERTEN HORSHAM, PA 19044 Phone: 6 PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. K,0.A1,i y Bh ° BuildingCitofAtlantic DepartmenteacAPPLICATION NUMBER `V 800 Seminole Road (To be assigned by the Building Department.) '' Atlantic Beach, Florida 32233-54454AUG 2Qt� �� — © (S I Phone(904)247-5826 •• Fax(904) 247-5845 `koliir)' E-mail: building-dept@coab.us Date routed: OS i'cr Li i 11- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: IU � ( la_n t L 6k,u(y1 p(• Department review required Yes No -� ^ Buildin Applicant: 'TD �' J -�'l( . Planning & onin� \_ Tree Administrator Project: (\ tkA) `f\OiAt C S k Ct0f) ublic Works C Public Utilities Public Safety Fire Services Review fee $ Dept Signature { Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 1pproved. I (Denied. ❑Notapplicable (Circle one.) Comments: BUILDING d PLANNING &ZONING Reviewed b : Date: 4,2 tip TREE ADMIN. Second Review: I 'Approved as revised. @Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 R.O.W. Permit Attachment of for R.O.W. Permit# issued , 20 17 Atlantic Beach, FL 32233 Owner's Name: TOLL FL VI, LP Property Address: 1684 Atlantic Beach Drive Subdivision: Atlantic Beach Country Club R.E. #: 169505-1715 REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT, issued on this ?;1416 day of July , 20 17, by Atlantic Beach, Florida, a municipal corporation organized and existing under the laws of the State of Florida, hereinafter referred to as "CITY" and TOLL FL VI,LP of Atlantic Beach, Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above (copies attached). This work is generally described as: Pavers in the Right of Way for the driveway. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty (30) days notice by CITY to the USER, said notice to USER shall be given by certified mail, return receipt requested, to the following address: 160 Cape May Avenue, Ponte Vedra, FL 32081 The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing, or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code, and all other land use and code requirements of the CITY, including City Code Section 19-7 (h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall, at the discretion of the CITY, be requested to submit as-built drawings showing the change within thirty(30)days after the day of completion. This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. DATED and SI ' ) this ?j 56- day of July , 20 17 • By: ` Pro' -rtytiv ner: Steven R. Merten, Division Sr. Vice President, TOLL FL VI,LP (to .e signed in presence of the Notary) STATE OF FLORIDA COUNTY OF ST.JOHNS On this 25 day of July , 20 17 , personally appeared before me, a Notary Public in and for said County and State, kik MCaut. , the property owner of I US 4 411A-Ki Ci • , Atlantic Beach, Florida, known to me to be the person(s) described in and who executed the foregoing instrument; who acknowledged to me that he or she executed the same freely and voluntarily and for the uses and purposes therein mentioned. No Tr ' blic in for said County and State MELISSA LIEBERMAN IA MY COMMISSION#FF055605 F��¢" EXPIRES September 18.2017 OF (407'398-0153 FloridallotaryService.com CITY OF ATLANTIC BEACH,FLORIDA, a municipal corporation: Approved: L.Yy glit Sco ° cams Interim Public Works Director File: 12/12/16 Page 2 of 2 s=A.N:r City of Atlantic Beach JS ��`. APPLICATION NUMBER Building Department sa (To be assigned by the Building Department.) --. 800 Seminole Road „'�� Atlantic Beach, Florida 32233-5445 511— 0 (S 3. � Phone(904)247-5826 • Fax(904)247-5845 �'r "„o E-mail: building-dept@coab.usAUG Date routed: OS I� City web site: http://www.coab.us 2 s APPLICATION REVIEW AND TRACKING FORM Property Address: 1U D(1 A _((_.01C_ 6ki(OA Pi • Department review required Yes No I Buildin Applicant: `To l,' ,,( Tric . Planning & onin Tree Administrator Project: \ Ur%) hDrf t t 1 S\ (aa0,(, c`eublic Works ub70Utilities ) Public Safety Fire Services Review fee $ V Dept Signature . ---:_m"....., Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. IDenied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING ../ Reviewed by: % Date: TREE ADMIN. Second Review: ['Approved as revised. Denied. ❑ ['Not applicable PWORKS Comments: PURL C UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. I INot applicable Comments: Reviewed by: Date: Revised 05/19/2017 '- 1r�J City of Atlantic Beach `' `',` PUBLIC UTILITIES DEPARTMENT 1200 Sandpiper Lane Atlantic Beach, FL 32233 j19. / (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date ' .1.- 5--/ 7 Project Address 7& 7 177,4A47 C (J(a�% D---- Number of Units I Commercial Residential Multi-Family v New Water Tap(s) & Meter(s Meter Size(s) /.3c1 New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter 7 Size /4 New Connection to City Sewer v 7/7 Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application Itles /7 — Q/ S 2 Water System Development Charge $ /, l (-( � C� , Vft— Sewer Sewer System Development Charge $4, v Y3 • CYC- Water Meter Only $ I g ST CO Reclaim Meter Only $ /RS, c) b Water Meter Tap $ Sewer Tap $ Cross Connection $ 5D. C20 Other $ TOTAL $ 5 CO /0 , ay (Notes) APPROVED Kayle Moore, P.E. �-\^ Date a Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED ifn [PE:i—� ©-� QVC i CTY OF ATLANTIC BEACH Beac 0" 9111F7- s, r SEP - 1 2017 800 Seminole Road i✓ sJ Atlantic h,Florida 32233 Telephone(904)247-5800 FAX(904)247-5845 REVISION REQUEST SHEET OR CORRECTIONS TO REVIEW COMMENT Date: 9/01/2017 Received by: Resubmitted: Permit Number: Res/7—a 1 s Original Plans Examiner: Project Name: Lot 84 Project Address: 1684 Atlantic Beach Drive , Contractor: Toll Bros., Inc. Contact Name: Brianna Tallman Contact Phone: 904-595-5243 Contact e-mail: btallman@tollbrothers.com Revision/Plan Check/Permit Fee(s)Due: $ Description of Proposed Revision to Existing Permit: Overall height has now been shown on the front elevation. Clouded and tawed on sheet A5.81. Also,A/C pad with distance is now shown properly on site plans to match floor plans. Additional Increase in Building Value: $ Additional S.F. Site Plan Revised: Public W/U Approval: By signing below.I (print name)b 1-Ct (IYY'lCLfl affirm that the above revision is i lusive of the proposed chang s. iii q � ran °1, 1. 1-1 Signature o. Contractor/Agent(Contractor must sign if increase in valuation) Date Office Use Only Date: Approved: Rejected: Notified by: Plan Review Comments: Department review required Yes No Buildin lam Zoning Tree ministratar Plans Examiner Public Works - 0- / 7 Public Utilities _ -_.._.__._------ ------_------ Public Safety Fire Services Date emoted 4/13/16 Rev 3 �� ZONING REVIEW COMMENTS \tss1 City of Atlantic Beach Community Development Department 800 Seminole Road Atlantic Beach,Florida 32233-5445 Date: 8/31/2017 Permit: RES 17-0152 Applicant: Toll Brothers Review: ZONING Address: 160 Cape May Ave, Ponte Vedra, FL Site Address: 1684 ATLANTIC Phone: 904-217-3852 BEACH DR RE#: 169505 1715 Email: btallman@tollbrothers.com Correction Comments 1. Height: Section 24-17 requires height to be measured from grade to the highest point of a building's roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height from grade on plans 2. A/C Location: Please clarify the location of the A/C equipment.The site plan and the floor plan show the A/C on opposite sides of the house. Informational Comments 1 Brian Broedell Planner F TOLLARCH ITECTU RE MEMO TO: Stacia Moore Atlantic Beach Heritage 160 Cape May Avenue Ponte Verda, Florida 32081 CC: Brianna Tallman FROM: Manuel Gonzalez, AIA Toll Brothers, Inc. DATE: August 31, 2017 RE: Atlantic Beach Heritage–Lot 0084–Davenport/Carribean–AO-152678-TBI-0084 City of Atlantic Beach –Zoning Review Comments Permit:RES17-0152 Dated 08-31-17 On the above referenced lot,this letter shall be used to revise or clarify the following condition(s): Permit Comment: #1 Section 24-17 requires height to be measured from grade to the highest point of a building's roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height from grade on plans. Toll Architecture Response: The overall height has been shown on the front elevation; clouded and tagged on sheet A5.81. Please feel free to contact this office if there are any questions regarding this matter. Sincerely, Q4'/ OF— F�` ``�! 0". 0000000-.0 1 k �I • C• p 0 0 • 0 0 '0 a AR9 o 0 0° i••••• 4C ao �j ,.%) oO0000• _ ��� %Pee",ED p���•� Manuel Gonzalez,AIA AR 96730 s-tV City of Atlantic Beach APPLICATION NUMBER �S r \ Building Department r cS� (To be assigned by the Building Department.) 800 Seminole Road ' �� Atlantic Beach, Florida 32233-5445 _- LS 11-_ O S3. Phone (904)247-5826 • Fax(904)247-5845 f '"i•!o;;l>r- E-mail: building-dept@coab.us Date routed: C)' 1 y City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1U 0("t an t L 6a01 Pi . Department review required Yes No I 4 Buildin• Applicant: it I 6.(0-s. , ( Planning & onin•) \� Tree Adminis rator Project: tiA) `(jOIk:_ l S\ ( [(, \1r\ < "ublic Works r � . 'ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: i APPLICATION STATUS Reviewing Department I First Review: ❑Approved. Denied. ❑Not applicable (Circle one.) Comments:fp BUILDING et 1t i c< i 6't'c,ce. fi 7C ("(4+ PLANNING &ZONING .�1'( Reviewed by: Date: O " TREE ADMIN. Second Review: Approved as revised. Denied. ❑ ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 t s [TY OF ATLANTIC BEACH' ,flj SEP 2611 800 Seminole Road te ` J Atlantic Beach,Florida 32233 Telephone(904)247-5800 _ FAX(904)247-5845 i ~ � REVISION REQUEST SHEET OR OFFICE COPY CORRECTIONS TO REVIEW COMMENT Date: 9/01/2017 Received by: Resubmitted: Permit Number: R&S 17_ 01 S D-- Original Plans Examiner: y71 Project Name: Lot 84 Project Address: 1684 Atlantic Mach Drive Contractor: Toll Bros., Inc. Cont: t Name: Brianna Tallman Contact Phone : 904-595-5243 Co. s e-mat . • -llman@tollbrothers.com Revision/Plan Check/Permit Fee(s)Due: $ SD-CPO Description of Proposed Revision to Existing Permit: Overall height has now been shown on the front elevation. Clouded and tagged on sheet A5.81. Also, NC pad with distance is now shown properly on site plans to match floor plans. Additional Increase in Building Value: $ Additional S.F. Site Plan Revised: Public W/U Approval: By signing below.I (print name) _�_ 11M0-1) affirm that the shoe revision is i lusive of the proposed chan s. oiQ ta, -( c't 1 in Signature of Contractor/Agent(cuntractor must sign if increase in valuation) Date Office Use Only - Date: ] • Pl./7 Appt. ed. X Rejected: Notified by Plan Review Comments: Co/dace" 71r, Pi c,, - i) *-s•010 copies a a7 .e-t. De•artment review required Yes o_l ' itilr)-- Buildin• 4 Planni g &Zoning Plans Examiner Tree Administrator 1 Public Works '1 y . .^� Public Utilities 9_ / Public Safety Date created 4/13/U,Rev 3 Fire Services l 1 g , ��i rs ZONING REVIEW COMMENTS;; City of Atlantic Beach J �� Community Development Department 800 Seminole Road Atlantic Beach,Florida 32233-5445 Date: 8/31/2017 OFFICE COPY Permit: RES 17-0152 Applicant: Toll Brothers Review: ZONING Address: 160 Cape May Ave, Ponte Vedra, FL Site Address: 1684 ATLANTIC Phone: 904-217-3852 BEACH DR RE#: 169505 1715 Email: btallman@tollbrothers.com Correction Comments 1. Height: Section 24-17 requires height to be measured from grade to the highest point of a building's roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height from grade on plans 2. A/C Location: Please clarify the location of the A/C equipment.The site plan and the floor plan show the A/C on opposite sides of the house. 1 1 Informational Comments Brian Broedell Planner TOLLARCH ITECTU RE MEMO TO: Stacia Moore Atlantic Beach Heritage 160 Cape May Avenue Ponte Verda, Florida 32081 OFFICE COPY CC: Brianna Tallman FROM: Manuel Gonzalez,AIA Toll Brothers, Inc. DATE: August 31, 2017 RE: Atlantic Beach Heritage—Lot 0084—Davenport/Carribean—AO-152678-TBI-0084 City of Atlantic Beach—Zoning Review Comments Permit:RES17-0152 Dated 08-31-17 On the above referenced lot, this letter shall be used to revise or clarify the following condition(s): Permit Comment: #1 Section 24-17 requires height to be measured from grade to the highest point of a building's roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height from grade on plans. Toll Architecture Response: The overall height has been shown on the front elevation; clouded and tagged on sheet A5.81. Please feel free to contact this office if there are any questions regarding this matter. Sincerely, •• OF Fee�N •0000°°- .0° (1 .),,1 ' 0 • 0 AR96 0 0 (j 0 1 G1 00 1.0 S`�'°°°°° `I`1� ED Manuel Gonzalez,AIA AR 96730 r..A„Jr City of Atlantic Beach APPLICATION NUMBER 41�;. ' (� Building Department (To be assigned by the Building Department.) - 800 Seminole Road O L C 1 1_ O 'S \ j Atlantic Beach, Florida 32233-5445 v-� �} of Phone(904)247-5826 • Fax(904)247-5845 oS M L[ I 1f Azolilr'' E-mail: building-dept@coab.us Date routed: -1 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1U o '"t � ..(1.(-)- (_t 6.01 L a4• Department review required Ye No Buildin 'V Applicant: To 1, &o . TrIC_ Planning &tonin J Tree Adminis rator Project: n UA \f\OMR_ _,on s\ rarrfiof) ublic Works ublic Utilities 1 Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING �Q Reviewed by: / Date: TREE ADMIN. Second Review: EApproved as revised. El Deni . Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 (:,' TI' ) FFICE,_,. ..tivo /D)1 -iYJ t2 ESI — C LS`,- ,.,„1..tvp.,, B�uilding Permit Application �p ` City of Atlantic Beach „ 800 Seminole Road, Atlantic Beach, FL 32233 ; J" Phone: (904) 247-5826 Fax: (904) 247-5845 I AUG 2 3 2017 Job Address: 1684 Atlantic Beach Drive Permit Number: Lot 84 Atlantic Beach CountryClub Unit 2, 67-132 08-2S-29E.152 169505-1795I Legal Description RE# Valuation of Work(Replacement Cost)$ 324,600.00 Heated/Cooled SF 2881 Non-Heated/Cooled 676 • Class of Work(Circle one):c ew- Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s) (Circle one): Commercial Residential • If an existing structure, is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New home construction. Florida Product Approval# See attached. for multiple products use product approval form Property Owner Information Name: TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May Avenue City Ponte Vedra State FL zip 32081 Phone 904-217-0739 E-Mail btallmantc'i tollbrothers.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) TOLL FL VI, LP Contractor Information Name of Company: Toll Bros., Inc. Qualifying Agent: Steven R. Merten Address 160 Cape May Avenue City Ponte-Vedra State FL Zip 32081 Office Phone 904-217-3852 Job Site/Contact Number 904-386-6472 State Certification/Registration# CGC1510225 E-Mail btallman@tollbrothers.com Architect Name& Phone# Toll Architecture (407) 248-5800 Engineer's Name& Phone# Lou Pontigo & Associates (904) 242-0908 Workers Compensation Policy #MWC30267702 / Expires: 9/1/2017 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOU' ' OTICE OF COMMENCEMENT. A (Signa ,re .f 0 er or Agent including Contractor) i•.natureofContractor) Si ned and s orn to(or affirmed) before me this 25-day of Signed and.worn to(or affirmed) before me this qday of U.K a 0 I] , by SSevp Mc 4eAi, DIV•SVP J(,fly , 2_01-1 , by S+e,/.. (Ilea-en, NI 3/P (Si_i'' re of Notary) ( .ture of N• .• I. IP of a -.,: MEI_[SSA LIEBERMAN 1��.'1,1'''",—, MELISSA LIEBERMAN :t MY COMMISSION =#FF055605 [ MY COMMISSION#FF055605 [L]Personally Known OR "?fcr c EXPIRES September 18.2017 M personally Known OR ,`'.'sop',.eP�`' EXPIRES September 18,2017 [ ]Produced ldentificatio (407)39q•0153 FloridallotaryService.com [ ]Produced Identification (407)3JB'0153 FloridallotaryService.com Type of Identification: Type of Identification: OFFICE COPY DO NOT WRITE BELOW- OFFICE USE ONLY Apphca I e Co•es: 2010 FLORIDA BUILDING CODE Review Result circle one : • Approved Disapproved � . Approved-w/ Conditions Review Initials/Date: .Y/2 ? -/7 Development Size . Habitable Space a 8.0 s,r. Non-Habitable r—: [Impervious area iliscellaneous Information )ccupancy Group 4-3 ype of Construction V (6 -umber of Stories 12 ming District A L1 c r ax. Occupancy Load - - . e Sprinklers Required )od Zone Jc raditions/Comments: Per,ny / 4FX. /7—O/5 - NOTICE OF COMMENCEMENT OFFICE COPY State of: FLORIDA Tax Folio No. 169505-1715 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 84 Atlantic Beach Country Club Unit 2.67-132 08-2S-29E.152 Address of property being improved: 1684 ATLANTIC BEACH DRIVE.ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 160 CAPE MAY AVE.,PONTE VEDRA,FL 32081 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: )/1\1Contractor: TOLL BROS.,INC. 4 Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: • Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN,Division Sr.Vice President Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year .4-m the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER / Signed: Date: 7 7J �7 Before me d is o? day of Ji.dy, 20/7 in the Co ty o St.Johns, Doc#2017174531,OR BK 18065 Page 1708, I State Of.lorida,has personally appeared STEVE MOLTEN/ Number Pages:1 ! Recorded 07/26/2017 at 02:33 PM, Notary Public at Large,State o�Florida,County of ST.JOHNS. Ronnie Fussell CLERK CIRCUIT COURT DUVAL MY commission expiresI of I7 COUNTY Personally Known: / or RECORDING$10.00 Produced Identification: 1 :zoaP4 .: MELISSA LIEBERMAN i t MY COMMISSION#FF055605 'fo , `ps'F' EXPIRES September 18.2017 • ` (407!3?n-0153 FloridallotaryService.com elb PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: Toll Brothers,Inc. Permit# 1e S / 7 - OFFICE FF I C C O^ Project Address: 1 J Atlantic Beach Drive,Atlantic Beach,FL 32233 Lot t' c r As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuilding.org_ Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6 Single-FL6506.4 Simpson Door Company Wood Door FL 14487.1 Therma-Tru Fiberglass/Wood Door N/A FL 5262.3 2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251 3. Sectional Clopay Building Products Section Ext.Door +20/-20 PSF FL15279.1/FL15279.3 4.Roll up 5.Automatic 6. Other B. WINDOWS 1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435 2.Horizontal slider PGT 5400 Vinyl Hor. Window +50/-50 FL 1844 3. Casement 4.Double hung 5.Fixed PGT 5400 Vinyl Fixed Window +50/-50 FL 5012 6.Awning 7.Pass-through 8.Projected 9.Mullion PGT Alum/Vinyl Mullions N/A FL 261 10.Wind Breaker 11.Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1 12.Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C.PANEL WALL 1.Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4 FL 12098.3; 12098.1; Nichiha Corp. Lap Siding and Shingles N/A 12875.1 2.Soffits/Ceilings James Hardie Building Products,Inc. Soffit Panels N/A FL 13265.1 Nichiha Corp. Soffit Panels N/A FL 12098.4 3.EIFS 4.Storefronts Kawneer Glass Windows Mitred Glass +30/-30 FL 10008.1 5.Curtain walls 6.Wall louvers 7.Glass block 8.Membrane 9.Greenhouse 10. Synthetic Stucco 11.Other D. ROOFING PRODUCTS 1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1 2.Underlayments Woodland Industries,Inc. Felt N/A FL 1814.12 Boral Roofing Roof Underlayment N/A FL 14317.1 3.Roofing fastners 4.Nonstructural metal roof Millennium Metals,Inc. Metal Roofing-M seam N/A FL 5211.3 R6 5.Built-up roofing 6.Modified bitumen 7.Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing 11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake Ni.A FL 13714.1 12.Roofing slate 13.Liquid applied roofing 14.Cement-adhesive coats 15.Roof tile adhesive 16.Spray applied polyurethane roof 17.Other i-Deck Walking deck membrane N/A FL 12407.1 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E.SHUTTERS 1.Accordion 2.Bahama 3.Storm panels Town and Country Industries Storm shutters N/A FL 11963 4.Colonial 5.Roll-up 6.Equipment 7.Other F. STRUCTURAL COMPONENTS 1.Wood connector/anchor Simpson Strong Tie Per engineering 2.Truss plates Alpine Engineered Truss plate conn. Per engineering 3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1 4.Railing 5.Coolers-freezers 6.Concrete admixtures 7.Material 8.Insulation forms 9.Plastics 10.Deck-roof 11.Wall 12.Sheds 13.Other G.SKYLIGHTS 1. Skylight Sun "I ek FGC Skylite FL 2442 2.Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1 7/16"Zip Wall-Structural 1 OSB(roof and wall);manufacturered by Huber Engineered Woods 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector,a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. r I cetti.fy that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. Brianna Tallman (Contractor Name) (Print Name) (Signature) Company Name: Toll Brothers,Inc. Mailing Address: 160 Cape May Avenue City: Ponte Vedra State: FL Zip Code: 32081 Telephone Number: 904 217-0739 Fax Number: Cell Phone Number: 904-405-8969 Email Address: btaIlman@tollbrothers.com OFFICE COPY ' FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION • • Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Davenport Bonus 2881 Left E Builder Name: Toll Brothers Street: Lot 84 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: . Owner: Toll Brothers Jurisdiction: 261300 . Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3577.8 sqft.) Insulation Area .2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3397.80 ftz b.Frame-Wood,Adjacent R=13.0 180.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 .4. Number of Bedrooms 4 d.N/A R= ft2 • 5. Is thisa worst case? No 10.Ceiling Types (2127.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1857.00 ft= , 6. Conditioned floor area above grade(ft2) 2881 b.Under Attic(Vented) R=19.0 270.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 • 11.Ducts R ft2 7. Windows(372.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 414 a. U-Factor: Dbl,U=0.34 372.00 ft2 • SHGC: SHGC=0.27 , b. U-Factor: N/A -ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 42.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: • 13.Heating systems kBtu/hr Efficiency ' • d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: • _ Area Weighted Average Overhang Depth: 2.495 ft. • Area Weighted Average SHGC: 0.270 14.Hot water systems •• 8. Floor Types (2881.0 sqft.) Insulation Area a.Natural Gas Tankless Cap:1 gallons EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 2127.00 ft' b. Conservation features b.Floor Over Other Space R=0.0 754.00 ft2 None c.N/A R= .ft2 15.Credits Pstat • Glass/Floor Area: 0.129 Total Proposed Modified Loads: 64.25 /� Total Baseline Loads: 80.38 SS if«n.i t...,...,.. . I hereby certify that the plans and specifications covered by ' Review of the plans and •��,fi```p 'r13E SZ,q?+'Tw+ • this calculation are in compliance with the Florida Energy specifications covered by this : v i ,'. ?; 0%,, Code. calculation indicates compliance 'y'r>,,, ''R << ,,.'.14:, _ 1. with the Florida Energy Code. :+r,,, a .; ;= :i•°;;• `�`,;�0 PREPARED BY: 474 completedi. `�•''• ` 1 ih Yn�r+ Before construction is w'�,.,f - DATE: o. .- -zer• . this building will be inspected for :0 I ,; compliance with Section 553.908 * y, Florida Statutes. 'i" m,...`�. .1,. I hereby certify that this building,as designed, is in compliance \,..efv......Aige.,.. 4`',,+' with the Florida Energy ode. a,,.. OD yy 'T ,,..it. • OWNER/A NT: J. . G _ L QiU11O-Pil�- BUILDING OFFICIAL: DATE: I'i `rt' 1 DATE: • - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: Davenport Bonus 2881 Left E Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2881 Lot# Owner: Toll Brothers Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: Lot 84 Atlantic Beach Permit Office: Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach , Family Type: Single-family FL, " New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site .Zone 97.5% .2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 2881 28056 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Intl!ID Finished Cooled Heated 1 Main 2127 .21270 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 754 6786 No 1 1 1 Yes Yes Yes FLOORS • ✓ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 190 ft 0 2127 ft2 ___ 0 0 1 2 Floor Over Other Space 2nd Floor ____ Y_ 754 ft2 0 0 0 1 'ROOF • / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2379 ft2 532 ft2 Medium 0.6 N 0.9 No 0 26.6 ATTIC • V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2127 ft2 N N 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING . V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 19 Blown 150 ft2 0:11 Wood 2 Under Attic(Vented) Main 38 Blown 1223 ft2 0.11 Wood 3 Under Attic(Vented) 2nd Floor 38 Blown 634 ft2 0.11 Wood 4 Under Attic(Vented) 2nd Floor 19 Blown 120 ft2 0.11 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below • V # Omt To wail Type Space R-VaIuP Ft In Ft In Area R.valup Fraction Absor r'radP9 1 E Exterior Frame-Wood Main 19 20 0 10 0 200.0 ft2 0 0.23 0.6 0 2 N Exterior Frame-Wood Main 19 77 0 10 0 770.0 ft2 0 0.23 0.6 0 3 NW Exterior Frame-Wood Main 19 11 2 10 0 111.7 ft2 0 0.23 0.6 0 4 W Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.6 0 5 S Exterior Frame-Wood Main 19 77 0 10 0 _ 770.0 ft2 0 0.23 0.6 0 6 E Garage Frame-Wood Main 13 20 0 9 0 180.0 ft2 0 0.23 0.01 0 , 7 SW Exterior Frame-Wood Main 19 6 .2 10 0 61.71t2 0 0.23 0.6 0 8 E Exterior Frame-Wood 2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 . _ 9 N Exterior Frame-Wood 2nd Floor 19 20 3 9 0 182.3 ft2 0 0.23 0.6 0 _10 W Exterior Frame-Wood 2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 • _11 S Exterior Frame-Wood 2nd Floor 19 20 3 9 0 182.3 ft2 0 0.23 0.6 0 - DOORS V 4 Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main -None A 3 8 .241ft2 2 ..E Wood Main None .4 2 8 8 21.3 ft2 r WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V It Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.34 0.27 24.0 ft2 7 ft 4 In 1 ft 0 in Drapes/blinds Exterior 5 • 2 N 2 Vinyl Low-E Double Yes 0.34 0.27 18.0 ft2 1-ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 3 N 2 Vinyl Low-E Double Yes 0.34 0.27 6.0-ft2 1 ft 4 in 1 ft 0 In None Exterior 5 4 N 2 Vinyl Low-E Double Yes 0.34 0.27 36.0 ft2 1 ft 4 in lit 0 in None Exterior 5 5 W 4 Vinyl Low-E Double Yes 0.34 0.27 36.0 ft2 9 ft 4 in 1 ft 0 in None Exterior 5 6 W 4 Vinyl Low-E Double Yes 0.34 0.27 36.0 ft2 1-ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 7 S 5 Vinyl Low-E Double Yes 0.34 0.27 20.7 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 8 N 9 Vinyl Low-E Double Yes 0.34 0.27 46.5 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 9 S 11 Vinyl Low-E Double Yes 0.34 0.27 15.5 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 10 S 11 Vinyl Low-E Double Yes 0.34 0.27 4.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 11 W 4 Vinyl Low-E Double Yes 0.34 0.27 21.3 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 12 S 5 Vinyl Low-E Double Yes 0.34 0.27 54.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 13 NW 3 Vinyl Low-E Double Yes 0.34 0.27 54.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 • 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software. Page 3 of 5 FORM R405-2014 GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation ' 1 453 ft2 453 ft2 52ft 9ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000309 2338 128.35 241.39 .2933 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 42 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 42 kBtu/hr 1260 cfm 0.7 1 sys#1 HOT.WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation • 1 Natural Gas Tankless Exterior 0.8 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM • V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply-- —Return— Air CFM 25 CFM25 HVAC# • V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool , 1 Attic 6 414 ft2 Attic 117 ft2 Default Leakage Garage (Default) (Default) 1 1 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES . Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar A r Ma X Jun X Jul X Au X Se Oct [ ]Nov Dec Heatinf X�Jan [X Feb ix' Mar f Apr f May f Jun f Jul 4 Aug Sep !xl Oct [X]Nov [x} Dec Ventin [ Jan [ Feb X Mar [X A r [ Ma [ Jun [ Jul [ Au Se Oct [X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 • Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(IND) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 i 1 i 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index, the more efficient the home. Lot 84 Atlantic Beach CC, Atlantic Beach , FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3397.80 ft2 b.Frame-Wood,Adjacent R=13.0 180.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area • a.Under Attic(Vented) R=38.0 1857.00 ft2 6. Conditioned floor area(ft2) 2881 b.Under Attic(Vented) R=19.0 270.00 ft2 7. Windows** Description Area c. N/A R= ft2 a. U-Factor: Dbl,U=0.34 372.00 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Garage 6 414 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 2.495.ft. Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14.Hot water systems 2 a.Natural Gas Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2127.00 ft EF:0.8 b.Floor Over Other Space R=0.0 754.00 ft2 b. Conservation features • c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ,,.••�',"""' Construction through the above energy saving features which will be installed (or exceeded) ,`"�off. E'STA� t• ,y .;" iz, in this home before final inspection. Otherwise, a new EPL Display Card will be completed 41/ ;<;.,. �• 40. i CO based on installed Cod compliant featur _ :'r,,,,; ;,::i=;:.�:,,,''ti;�0 Builder Signature: aceiy.dA Date: (. ..,•a,, - a i Address of New Home:(,Q pi- n}--�'( -T ' City/FL.Zip: 3 Z� 33 • ,:-.4110. Address .. 'ac,.' `.,COD W-.;0,„„ *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Lot 84 Atlantic Beach CC Permit Number: Atlantic Beach ,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. 0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,If installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. 0 R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. O R403;1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. o R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. • R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-In testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: ' 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing Is not mandatory for buildings complying by Section R405 of this code. 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a • downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). o R403.4.4.1 Storage water heater temperature controls o R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s) • of combustion types of service water heating systems to be turned off. p R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 In Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment Installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2:1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403,5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403,6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the • equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected In Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed In an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9;1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance • with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: ' 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Davenport Bonus 2881 Left E Builder Name: Toll Brothers Street: Lot 84 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. ✓ Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed.• Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the.foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. / - Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I • vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Davenport Bonus 2881 Left E Builder Name: Toll Brothers Street: Lot 84 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 Cond. Floor Area:: 2881 sq.ft. Cond.Volume: 28056 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA: _ •Eq LA: ACH: ACH(50): SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. `......Ya......ai;. I hereby certify that the above envelope leakage Where required by the code official, s``�110ESTA? `',, performance results demonstrate compliance testing shall be conducted by an *, ;0 . with Florida Energy Code requirements in approved third party. A written t�"iii �' % .3a.,�a� accordance with Section R402.4.1.2. report of the results of the test shall 3 be signed by the third party a" • AL `� conducting the test and provided to ' ��. SIGNATURE: the code official. + f0`" Nt. COD ..;1`%;':0•+' PRINTED NAME: `'t��............ DATE: BUILDING OFFICIAL: DATE: 7/14/2017 2:26 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 OFFICE COPY s Job: vProject Summary Date: Entire House By: Saldie Guintivano J f =-.. McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,FI 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904) 217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: The Davenport Bonus Desi•n Information Weather: St.Augustine, FL. Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 30124 Btuh Structure 24519 Btuh Ducts 3857 Btuh Ducts 4872 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33982 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29391 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4151 Btuh Ducts 844 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2881 2881 Equipment latent load 5445 Btuh Volume(ft3) 28606 28606 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 34836 Btuh Equiv.AVF(cfm) 153 76 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0420000A0 Cond CH14NB0420000A0 AHRI ref 9162578 Coil FB4CNP042L AHRI ref 9162578 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 30 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=28°F Backup: Input= 10 kW, Output=34224 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. :.. vvri ht$oft. 2017-Jul-1413:37:47 Comfort Builder by Wrightsoft 17.0.23 RSU03444 Page 1 ..n\Toll Brothers\Davenport Bonus 2881 Left E.rup Calc=MJ8 Front Door faces: E N ' e First Floor 0 0 3"Fan aG 6x12 Balh2 6x12 8x4 7• Bed3; 12x12 4edz 6 x 12 ��cwe�.�•■ Kitchen 2" 10x6 / 18x24 14"r„........--212 x 12 6" 9.. Dining Ali Foyer c sx 0 s' Great/II 1 2x6 q••• 2 10 10 7" 4x8 6 x 9.. 12' k4,--WI �J 105 10x10 16x16 (� 1y^ ri AJ e. 14 • • ;x4 ?Laundry • 6 x 70 / """""'•� 1,..L. 70 16" 16x76 1 14" 6 � `Garage 10 x 6 attic Master 6 Sup Riser Di ucecx 10" • 11 M.Bath Fan 0 18" 6x7 6" 3" Job#: McGowan's Heating & Air Conditions... Scale: : 128 Performed by Saldie Guintivano for: Page 1 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 17.0.23 RSU03444 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2017-Jul-14 13:38:52 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey@mcgowansac.com smerten@tollbrothersinc.com g y@mcgowansac.com ...\Davenport Bonus 2881 Left E.rup N N 2nd loft 10x6 10x6 6" 12 x 12 AI!�J 12 x 12 10" Sup Riser 10" 10" bed4 4 x 8 4'• 6x10 Ih3 3"Fan .lob#: McGowan's Heating & Air Conditions... Scale: : 128 Performed by Saldie Guintivano for: Page 2 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 17.0.23 RSU03444 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2017-Jul-14 13:38:52 Phone:(904)217-0739 Fax:(904)814-8173 mc www. owansac.com korey@mcgowansac.com smerten@tollbrothersinc.com g 1Davenport Bonus 2881 Left E.rup Manual S Compliance Report Job: rsi) Date: j Entire House By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.corn Web:www.mcgowansac corn Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904) 217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 29391 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 5445 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 34836 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Sensible capacity: 29526 Btuh 100%of load Latent capacity: 6739 Btuh 124%of load Total capacity: 36265 Btuh 104%of load SHR: 81% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 33982 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Output capacity: 32361 Btuh 95%of load Capacity balance: 28 °F Supplemental heat required: 1621 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 10.0 kW 101%of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2017-Jul-14 13:37:47 wrightsoft` Comfort Builder by wrightsoft 17.0.23 RSU03444 Page 1 ACLA ...n\Toll Brothers\Davenport Bonus 2881 Left E.rup Calc=MJ8 Front Door faces: E Duct System Summary Job: n , Date: r -v- Entire House By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey©mcgowansac.com Web.www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.269/0.121 in H2O 0.269/0.121 in H2O Lowest friction rate 0.077 in/100ft 0.077 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length (TEL) 504 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk Bath 2 h 992 36 21 0.119 4.0 Ox 0 VIFx 36.0 190.0 st6 Bed 2 h 4571 165 116 0.115 7.0 Ox 0 VIFx 43.7 190.0 st6 Bed 3 h 1407 51 43 0.118 6.0 Ox 0 VIFx 37.2 190.0 st6 Dining h 2369' 85 62 0.118 7.0 Ox 0 VIFx 43.4 185.0 st6 Foyer h 2203 79 67 0.113 6.0 Ox 0 VIFx 42.6 195.0 st6 Great-A c 2608 73 109 0.077 7.0 Ox 0 VIFx 73.0 275.0 st5 Great-B c 2608 73 109 0.079 7.0 Ox 0 VIFx 66.2 275.0 st5 Kitchen c 4635 143 193 0.077 7.0 Ox 0 VIFx 72.7 275.0 st5 Laundry c 886 16 37 0.110 5.0 Ox 0 VIFx 49.0 195.0 st3 M WIC c 12 0 0 0.096 4.0 Ox 0 VIFx 49.1 230.0 st4 M.Bath h 2433 88 46 0.115 6.0 Ox 0 VIFx 43.5 190.0 st3 Master c 1963 69 82 0.095 6.0 Ox 0 VIFx 52.4 230.0 st4 Master-A c 1963 69 82 0.098 6.0 Ox 0 VIFx 45.1 230.0 st4 Toilet c 50 2 2 0.113 4.0 Ox 0 VIFx 43.0 195.0 st3 bath 3 h 992 36 28 0.134 4.0 Ox 0 VIFx 30.5 170.0 st7 bed 4 c 1792 71 75 0.139 6.0 Ox 0 VIFx 28.5 165.0 st7 ctst c 47 1 2 0.097 4.0 Ox 0 VIFx 48.6 230.0 st4 loft h 2345 85 75 0.133 6.0 Ox 0 VIFx 37.9 165.0 st7 loft-A h 2345 85 75 0.131 6.0 Ox 0 VIFx 39.8 165.0 st7 2017-Jul-14 13:37:47 . � wrightsoftA Comfort Builder by Wrightson 17.0.23 RSU03444 Page 1 ...n\Toll Brothers\Davenport Bonus 2881 Left E.rup Calc=MJ8 Front Door faces: E Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st7 Peak AVF 276 253 0.131 505 10.0 0 x 0 VinIFIx st2 st5 Peak AVF 289 411 0.077 523 12.0 0 x 0 VinIFIx st4 st4 Peak AVF 428 577 0.077 539 14.0 0 x 0 VinIFIx st3 st3 Peak AVF 533 662 0.077 619 14.0 0 x 0 VinIFIx st1 st6 Peak AVF 416 310 0.113 530 12.0 0 x 0 ViniFlx st1 st1 Peak AVF 949 972 0.077 696 16.0 0 x 0 ViniFlx st2 Peak AVF 276 253 0.131 505 10.0 0 x 0 VinIFIx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk • rb4 Ox 0 435 495 151.7 0.080 1418 8.0 Ox 0 VIFx rt1 rb3 Ox 0 201 145 156.3 0.077 454 9.0 Ox 0 VIFx rt1 rb1 Ox 0 589 586 145.2 0.083 551 14.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 1225 1225 0.077 693 18.0 0 x 0 VinlFlx 2017-Jul-14 13:37:47 wrightsoft2 Comfort Builder by Wrightsoft 17.0.23 RSU03444 Page 2 ...n\Toll Brothers\Davenport Bonus 2881 Left E.rup Calc=MJ8 Front Door faces: E T'NStatic Pressure and Friction Rate Dae: ill : , " Entire House By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0.06 0.0E Heat exchanger 0 0 Supply diffusers 0.02 0.02 Return grilles 0.03 0.02 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.39 0.39 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 14 14 Measured length of trunk 59 28 Equivalent length of fittings 275 115 Total length 348 156 Total effective length 504 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.077 OK 0.077 OK Return Ducts 0.077 OK 0.077 OK Fitting Equivalent Length Details Supply 4AD=60, 11C=40, 11G=5, 11C=40, 11G=5, 11C=40, 11C=40, 11G=5, 1A=35, 11G=5: TotalEL=275 Return 6L=20, 11C=40, 11G=5, 11G=5, 5E2=35, 11G=5, 11G=5:TotalEL=115 2017-Jul-14 13:37:47 "+- wrightsoft' Comfort Builder by Wrightsoft 17.0.23 RSU03444 Page 1 ACS ...n\Toll Brothers\Davenport Bonus 2881 Left E.rup Calc=MJ8 Front Door faces: E