2347 FIDDLERS LN - POOL DRAWINGSGENERAL NOTES 1. FOR POOL PLAN, SIZE, DECK EXTENTS, SPECIAL DETAILS, SEE CONTRACTO FrS POOL PLAN 2. ALL POOL CONSTRUCTION SHALL COMPLY WITH FLORIDA BUILDING CODE 2014 AND FLORIDA BUILDING CODE RESIDENTIAL 2014 TOGETHER WITH LATEST REVISIONS AND ANSI/NSPI NAT IONAL STANDARDS FOR RESIDENTIAL INGROUND SWIMMING POOLS AND ANSI/NSPI NATIONAL STAN DARD-3 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS AND THE NATIONAL ELECTRIC CODE - LATE T. 3. ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL UNLESS OTHERWISE NOTED. 4. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACK AREAS. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT AND ALL DIMENSIONS SHOWN PRIOR TO CONSTRUCTION. 5. CONTRACTOR SHALL DETERMINE LOCATION OF ALL UTILITIES IN RELATIO TO POOL AND ITS EQUIPMENT AND ENSURE MINIMUM CLEARANCE IN ACCORDANCE WITH LOCAL REGULATION AND ORDINANCES. 6. CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY FENCING AROUND CONSTRUCTION AREA TO PREVENT UNAUTHORIZED ENTRY INTO POOL AREA. 7. IF A MANUAL FILL WATER SUPPLY IS PROVIDED; A MINIMUM W ATMOSPHE C BREAK WILL BE PROVIDED, IF AN AUTOFILL ASSEMBLY IS INSTALLED, A BACKFLOW PREVENTER WILL BE REQUIRED ON THE POTABLE WATER LINE USED TO SUPPLY THE POOL. 8. ALL STRUCTURAL, FILTRATION, AND ELECTRICAL DETAILS OUTLINED IN TH ESE DRAWINGS ALSO RELATE TO SPA CONSTRUCTION. 9. ALL POOL AND SPA HEATERS SHALL BE EQUIPPED WITH A READILY ACCE IBLE ON-OFF SWITCH MOUNTED OUTSIDE THE HEATER TO ALLOW THE HEATER TO BE SHUT OFF WITHOUT DUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RE -LIGHTING THE PILOT L 3HT. EFFICIENCY RATINGS MUST COMPLY WITH THE FLORIDA ENERGY CONSERVATION CODE. 10. TO EMPTY THE POOL FOR ANY REASON, THE HYDROSTATIC UPLIFT PRESE JRE MUST BE ELIMINATED. THE OWNER MUST CONSULT A CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURE. CONTRACTOR SHOULD CONSIDER INSTALLATION OF GRAVEL BED WITH UNDERDRAIN PU APING SYSTEM IN AREAS WHERE GROUNDWATER COULD RESULT IN UPLIFT PRESSURES THAT COULD FL O POOL OUT OF THE GROUND.. 11. THE RESIDENTIAL SWIMMING POOL BARRIER AND/OR ITS COMPLIANT SAFE TY COMPONENTS SHALL BE IN PLACE PRIOR TO FILLING OF THE POOL. 12. CODE VIOLATIONS FOUND DURING INSPECTION ARE REQUIRED TO BE CO RECTED. PLAN/PERMIT ISSUANCE DOES NOT GRANT APPROVAL OF A CODE VIOLATION. 13. A HYDROSTATIC RELIEF VALVE SHALL BE INSTALLED IN POOLS LOCATED 11 J AREAS WHERE THE GROUND WATER TABLE OR POTENTIAL PERCHED WATER INTERSECTS THE POOL DURING ANY PERIOD OF ANY GIVEN YEAR. STRUCTURAL NOTES 1. ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 40. REINFORCING SHALL BE #3 BARS AT 12" ON CENTER EACH WAY WITH 15" LAP JOINT IN WALLS AND FLOORS UP TO 6 FEET DEPTH. BETWEEN V AND 19, USE 93 BARS AT 6" ON CENTER VERTICALLY IN THE AREA OVER 6 IN DEPT 1. (ALTERNATE: #4 BARS AT 16" ON CENTER EACH WAY WITH 20" LAP JOINT W WALLS AND FLOORS UP TO FEET IN DEPTH: BETWEEN 6 AND 10', USE #4 BARS AT 8" ON CENTER VERTICALLY IN THE AREA OVER 6 IN DEPTH). NOTE APPLIES TO NORMAL, NON -EXPANSIVE SOILS ONLY. NORMAL SOILS ARE ASSUMED TO POSSESS EQUIVALENT FLUID PRESSURE OF 35 PCF AND UNIT WEIGHT OF 120 PCF. IF CONCRETE IS CASTAGAINST BARE EARTH WITHOUT SEPARATION BARRIER, MINIMUM COVER SHALL BE 3"; WITH A Bfi RRIER (STEELTEX) BETWEEN CONCRETE AND EARTH, MINIMUM COVER SHALL BE 2 ". 2. REINFORCING STEEL SCHEDULE IN NOTE #1 ABOVE APPLIES TO POOL WA LS W/ 5-1/2" THICKNESS AND FLOORS WITH 5-1/2" THICKNESS. STEEL SCHEDULE MUST BE REVISED FO I WALLS OR FLOORS THICKER THAN 5-1/2". FLOORS AND WALLS SHALL BE CONSTRUCTED OF PNEUMAT CALLY APPLIED CONCRETE WITH A COMPRESSIVE STRENGTH OF 4,000 PSI IN 28 DAYS. CONCRETE DECKS ALL BE 2,500 PSI. CONCRETE CONSTRUCTION WILL CONFORM TO ACI STANDARD 318, MINIMUM WALL I 11CKNESS MUST BE INCREASED FOR DEPTHS GREATER THAN 8'0". NOTE APPLIES TO "NORMAL" SOILS ONI. Y. 3. POOL OR PATIO SHALL BEAR ONLY ON ROCK OR CLEAN SAND, WHICH SHi LL BE COMPACTED TO PROVIDE A STRUCTURALLY SAFE BEARING CAPACITY. ANY UNSUITABLE MATERIAL E 4COUNTERED IN EXCAVATION SHALL BE REMOVED IN ITS ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH ACCEPTABLE MATERIAL AND PROPERLY COMPACTED. WHERE UNSUITABLE MATERIAL CANNOT BE REMOVED, THE POOL MUST BE REDESIGNED. 4. SOILS SHALL HAVE MINIMUM BEARING VALUE OF 1000 PSF, 1500 PSF FOR REESTANDING WALL. 5. THE CONTRACTOR MUST PROTECT EXISTING STRUCTURES FROM FAILLIF E BY ACCEPTABLE METHODS. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF (STING STRUCTURES. CONTRACTOR SHOULD CONSULT WITH A STRUCTURAL ENGINEER IF EXIS TNG STRUCTURES HAVE THE POTENTIAL TO INFLUENCE FORCES ON THE POOL WALL, OR VICE VERSA. 6. SHOTCRETE (WET OR DRY) SHALL BE PROPORTIONED AND PLACED ACC( RDING TO UBC SECTION 1922 AND ACI 506. CEMENT TO AGGREGATE, IN DRY WEIGHT, SHALL NOT BE LESS I -IAN FIVE TO ONE. 7. SHOTCRETE SHALL NOT BE APPLIED IF AMBIENT AIR TEMPERATURE IS LE 3S THAN 40F AND FALLING, OR IF TEMPERATURE IS GREATER THAN 100F. NEVER APPLY SHOTCRETE IN HE VY RAIN. 8. SUBSTRATE SHOULD BE FOG -SPRAYED WITH WATER PRIOR TO SHOTCR TE APPLICATION TO ALLOW HYDRATION AND LIMIT RAPID DRYING OF CONCRETE, AND TO COOL REINFORCEMENT STEEL. 9. IF FLOOR IS TO BE POURED AND WALLS CONSTRUCTED WITH SHOTCRET E. THE FLOOR SHALL BE POURED PRIOR TO CONSTRUCTION OF THE WALLS. FOR SHOTCRETE FLOORS, APPLICATION SHOULD COMMENCE IN CORNERS AND WORK TOWARDS THE CENTER OF THE POOL FOLLOWING NALL CONSTRUCTION. 10. IF EXPANSIVE SOILS (CLAYS) ARE ENCOUNTERED, THE SIDES AND BOTTC M OF THE POOL EXCAVATION MUST BE IN MOIST CONDITION IMMEDIATELY PRIOR TO PLACEMENT OF SI iOTCRETE. 11. REINFORCEMENT STEEL SHALL MEET ASTM A615-10: LAP SPLICES SHALI BE AT LEAST 40 BAR DIAMETERS. UBC SECTIONS 1907, 1912, AND 1924 SHALL BE USED AS A GUIDELINE. 12. LAP SPLICES SHALL BE STACKED INLINE WITH SHOTCRETE SPRAY DIREC ION, NOT SIDE-BY-SIDE PERPENDICULAR TO SPRAY. 13. REBAR PLACEMENT SHOULD BE SUCH THAT THE DISTANCE FROM THE INSIDE SHOTCRETE FACE TO REBAR SHOULD BE A MINIMUM OF THE TOTAL SHOTCRETE THICKNESS MINUS 3". 14. IN AREAS WHERE THE STEEL REINFORCEMENT IS FORCED TOGETHER DUE TO CURVATURE OF THE WALL, 1 - #4 BAR MAY BE SUBSTITUTED FOR 2 - #3 BARS IN ORDER TO MAINTAIN MINIMUM 2.5 INCH SPACING. 15. UP TO 2" DIAMETER PIPING MAY BE PLACED IN THE LOWER OUTSIDE COP NER OF THE BOND BEAM PROVIDED A MINIMUM OF 1.5" CLEARANCE IS MAINTAINED BETWEEN THE PIPES AND ANY PARALLEL REINFORCEMENT. 16. AN ENGINEER SHOULD BE CONSULTED IF UNUSUAL CONDITIONS ARE EN OUNTERED. 17. IF A RAISED BOND BEAM EXCEEDS 2'O" AND SERVES AS A RETAINING WA.L FOR SOIL, THE RAISED PORTION SHOULD HAVE WALL DRAINAGE INSTALLED TO PREVENT BUILD-UP OF H DROSTATIC PRESSURES. LADDER MINIMUM REINFORCEMENT #3 TYPICAL STRUCTURAL NOTE 5 z CROSS BARS SPACED 12" O.C. E.W. TYPICAL POOL T TO 8' DEEP BRACE RECOMMENDED TYPICALcc n SHOTCRETE STEPS OR BENCHES AS NEEDED RADIUS \ x EXTRA TRANSVERSE REINFORCEMENT43 10' LENGTH C, VDISTURBED :)IL (NO VOIDS) SPACED ON 12 CENTERS 14" 18" BETWEEN MAIN BARS, CENTERED ON TRANSITION (MAY BE ELIMINATED IF NO 143 DIAGONAL, E.W.,AT DRAIN TRANSITION EXISTS) SIMILAR TO LIGHT N16HE DETAIL LONGITUDINAL POOL SECTION NTS I - ;; TYPICAL SWIMOUT DETAIL N.T.S. FINISHED POOL FLOOR ADJUSTABI E FLOOR INLET. AFTER FULL CLOSE, BACK OPEN 1/2 TURN. (FLOOR INLETS SHALL BE FLUSH WITH POOL FLOOR.) THE FOLLOWING TABLE PROVIDES MAXIMUM FLOW THROUGH SCH40 PVC PIPE WITHOUT EXCEEDING THE MAXIMUM STANDARDS FOR VELOCITY (FT/SEC) PIPE SIZE 6 FT/S 8 FT/S 10 FT/S 1" 16 GPM 21 GPM 26 GPM lye 37 GPM 50 GPM 62 GPM 2" 62 GPM 82 GPM 103 GPM -� SUPPLY HEADER NOTE: CONCRETE ENCASEMENT OCCURS ONLY AT THE RETURN FITTING. POOL FLOOR INLET DETAIL N. T. S. PLUGGED EQUALIZER PORT TO PUMP SUCTION 2)i" 88 GPM 117 GPM 146 GPM 3" 138 GPM 181 GPM 227 GPM 4" 234GPM313 GPM 392 GPM 6" 534 GPM 712 GPM 900 GPM PUMP SIZE WILL VARY DEPENDING ON THE PUMP SPECIFICATION AND THE TOTAL DYNAMIC HEAD FOR THE SPECIFIC POOL NEEDS. o> � WATER LEVEL (CENTER LINE OF SKIMMER) VACUUM FITTING - SEE NOTE 3 BELOW NOTES: 1. SKIMMER SHALL BE VENTED TO ATMOSPHERE THROUGH OPENINGS IN THE LID; THROUGH AN ENGINEERED VENT PIPE, OR INCORPORATE AN EQUALIZER LINE. 2. EQUALIZER PORT SHALL BE PLUGGED. 3. WHEN USED, VACUUM CLEANER FITTINGS SHALL BE LOCATED IN AN ACCESSIBLE POSITION AT LEAST 6" AND NO GREATER THAN 12" BELOW THE MINIMUM OPERATIONAL WATER LEVEL AND BE FITTED WITH A SELF CLOSING, SELF LATCHING FITTING IN ACCORDANCE WITH IAPMO SPS 4. SKIMMER AND VACUUM FITTING DETAIL ESCUTCHEON PLATE 3"-6" -� WATER ANCHOR SOCKET LEVEL LADDER TREADS SHALL BE RUBBER BUMPER SLIP -RESISTANT POOL WALL 5-1/2' LADDER DETAIL N.T.S. FLOOR REINF. AS PER - STANDARD PLAN (�' - - 1 - -^ TO PUMP I 1 1/2" DIA. HYDROSTATIC RELIEF PIPE BOTTOM 12" PERFORATED. (SEE GENERAL NOTE 13) 314"- 1 - 1/2" DRAIN ROCK 2 - #3 BARS BENT AS SHOWN EACH II: WAY AND LAPPED EE18" WITH FLOOR I REINFORCEMENT. io II CLEARANCE FROM EARTH railove CITY OF ATLANTIC BEACH 24" SQ SEE PERMITS FOR ADDITIONAL ORO REOUIREMENTS AND CONDITIONS MAIN DRAIN DETAIL // DATE:_ra:�� OFFICE COP REVIEWED BY:�,_�MM�f� PIAN SSPUM ONE YEAR FROM THE SIGNATURE DATE OR THE Z"ZCTIVE DATE OF A MAJOR FIDRM HURDING CODE CHANGE WHICHEVER IS SOONER -(umiffst Certificate of A6tfio�No. 28177 -483701 337 PABLO'OAXSG3URT, SLRTE 101 JACKSONVILLE, FL 32.da : . 304-22_3-9 73 FAX; 866- z�-9236 RESIDENTIAL SWIMMING POOL GENERAL NOTES AND DETAILS THE BATTS COMPANY CPC037046 CGC055163 1602 NORTH 3rd STREET JACKSONVILLE BEACH, FL 32250 (904) 246-2455 (904) 249-0457 DWG. BY: RRW NOT TO SCALE SHEET 1 OF 5 APPROVED BY: SEL 1/2" WHITE VINYL JOINT 8"'11" WATERLINE i -E, STRIP (NIA FOR PAVER GLAZED, MIN 4" DECKS) CONCRETE DECK (OPTIONAL) WITH SLIP RESISTANT TOPPING DEPTH THICKNESS ON COMPACTED GROUND WITH ALL ORGANIC MATERIAL o REMOVED. 4' THK. WITH FIBER TYPICAL WALL R MESH, 6" WITH #3 REBAR URN, OR VACUUM FITTING, WITH 3 EA #3 REBAR CONTINUOUS 18" WATER STOP FLA qGE LAP SPLICES AS NECESSARY LIGHT FIXTURE & SEE STRUCTURAL NICHE 3" _ MIN. R=6'WHENH= -0" RADIUS INCREASES 6" FOR EACH T OF DEPTH < 5'-0" R = 21-0" WHEN H RADIUS INCREASES = T-0" T FOR EACH V OF DEPTH > 5'-0" QUARTZ A GREGATE PLASTER FINISH STD. REINF.: SHO rCRETE WALL #3 REBAR @ 12" O.C. B.W. MIN. 5-1/ SHELL COVER 3" (EARTH SIDE), 2" THICKNESS (POOL SIDE). REFER TO STRUCTURAL NOTE#1 FOR ��— WALLS= NL ALTERNATE SCHEDULE. — INCH CENTERS AT 5-1/2" WALL THK TYPICAL POOL WALL SECTION SCALE: N. T. S. SPA WALL SCHEDULE OF CONCRETE DEPTH THICKNESS WATER FT WINCHES 3.0 5.1/2" 3.5 5-1/2" SEE SPA WAI. L SCH. SEE STRUCTURAL 4:0 8 6" NOTE 15 4.5 10 2 - #3 BARS _ (OR 1 - #4 BAR) It I I �- 5.0 10 Ir I I' HORIZ. REIN. #3 BARS 8" L O.C. FOR FREE STANDING VERTICAL REINFORCEMENT #3 -12 WALLS= NL TYPICAL REINF. INCH CENTERS AT 5-1/2" WALL THK VERT. REINF. SEE SPA I 12" O.C. E.W. CONSULT ENGINEER FOR WALL SCH. ( REINFORCEMENT AT GREATER THK NOTE: GREATER WALL THICKNESS (T) OR DOUBLE CURTAIN REINFORCEMENT MAY BE USED IF — —� — — REQUIRED FOR AESTHETICS OR PLUMBING FLOOR REINF. CONT. FROM SPA TO POOL MIN. 15' LAP EITHER DIRECTION SPA DETAIL N.T.S. :1 ar 3" MIN. (TYP.) EXPANSION JOINT 8"-11 G DECK SLAB VINYL DECK SLAB 6" rl07 1Z fn —1 TILE _ 1 to °D o SEE STRUCTURAL NOTE 15 I ALTERNATE LOCATION OF ' BOND BEAM REIN. 3-#3 BOND BEAM BAR (TYP) BARS (TYP. FOR ALL BOND BEAMS) M 3" ` CANTILEVER DECK DETAIL COPING DETAIL MIN. z ¢ N.T.S. N.T.S. J J roQ 2-#3 EACH WAY) I� 0 5-1/2" EXPANSION JOINT DECK SLAB LIGHT NICHE DETAIL BEND DOWN N. T. S. 243— — — BOND BEAM BARS ED #3 BAR BEND I III " AS SHOWN _ = =C � 343 I a ( MINIMAL BOND BEAM SKIMMER DETAIL N.T.S. N.T.S. NOTE: MAYBE USED WITH SAND, GRAVEL, OR ROCK SOIL CONDITIONS ONLY. 10" MIN. WATER ALTERNATE TROUGH 12" PLUMBING LOCATION III- 1 AT GRADE � _ AT GRADE to �I WATER io ( OR ELEVATED TROUGH OFFICE COPY F"� I I I A I OR 3 II I plAN EYPHm ONE YEAR FROM THE SIGNATURE DATE OR THE BFPSLflYE �� CHANGE is s°�Dw?w RESIDENTIAL SWIMMING POOL SHEER DESCENT DETAIL N.T.S. Q t STRUCTURAL DETAILS Certificate of Authority, No. 28177 4337 PABLO OAKS COURT, SUITE 101 JACKSONVILLE, FL 32224 THE BATTS COMPANY 904-223-9773 FAX: 866-832-9236 CPC037046 — CGC055163 1602 NORTH 3rd STREET JACKSONVILLE BEACH, FL 32250 (904) 246-2455 (904) 249-0457 I W t {1 --/. 5 q DWG. By: RRW 2 NOT TO SCALE SHEET. OF 5 APPROVED BY: lEL / PROFESSIONAL ENGINEER TO" MIN. (EDGE OF 3'0" MIN. (EDGE OF OUTLET) SINGLE UNBLOCKABLE CHANNEL OUTLET TO SINGLE PUMP OUTLETS IN PARALLEL TO ONE PUMP OUTLETS IN PARAL EL TO DUAL PARALLEL OUTLETS TO TWO PUMPS PUMPS IN _PARALLE L NOTES: SINGLE UNBLOCKABLE CHANNEL OUTLET TO TWO PUMPS 1. DUAL OUTLETS SHALL BE SEPARATED BY MINIMUM 3 FEET FROM OUTSIDE DGE TO OUTSIDE EDGE OF OUTLET: 2. TEE ON THE SUCTION MANIFOLD SERVING THE OUTLETS SHALL BE LOCAT D MIDWAY BETWEEN THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE FLOW RATING OF EACH COVERIGRATE SHALL BE AT LEAST EQUAL TO THE SYSTEM'S MAXIMUM FLOW RATE. ANY SHAPE 4. OUTLETS MAY BE LOCATED ON SEPARATE PLANES IN LIEU OF THE 3'0" SE ARATION REQUIREMENT, I.E.ONE (1) ON THE BOTTOM AND ONE (1) ON THE VERTICAL WALL, OR ONE (1) EACH ON TWO (2) SEPARATE VERTICAL WALLS DUAL SUCTION OUTLET ARRANGEMENTS 3'0" MIN. (EDGE OF OUTLET) 3'0" MIN. (EDGE OF OUTLET) 3.0" MIN. (EDGE OF OUTLET) LARGE UNBLOCKABLE OUTLET OF ANY SHAPE TO SINGLE PUMP NOTES: 1. SINGLE CHANNEL OUTLET: 3" OR GREATER IN WIDTH AND 31" OR GREATER IN LENGTH (APPLIfS TO PERFORATED AREA). 2. SINGLE UNBLOCKABLE OUTLET: SHALL BE OF ANY SIZE AND SHAPE SUCH THAT A REPRESENTATION OF THE TORSO OF THE 99TH PERCENTILE ADULT MALE CANNOT SUFFICIENTLY BLOCK IT TO THE EXTENT THAT IT CREATES A BODY SUCTION ENTRAPMENT HAZARD. THE TORSO IS REPRESENTED AS A RECTANGLE 18"X 23" WITH CORNERS OF RADIUS 4". SINGLE UNBLOCKABLE SUCTION OUTLET ARRANGEMENTS OUTLETS IN PARALLEL OUTLETS IN PARALLEL OUTLETS IN PARALLEL SYMMETRIC PIPING E CENTRICALLY TAPPED PIPING LOOPED PIPING NOTES: ET. 1. THE OUTERMOST OUTLETS SHALL BE SEPARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO'OUTSIDE EDGE OF OUTL 2. TEE ON THE SUCTION MANIFOLD SERVING THE OUTLETS SHALL BE LOCATED MIDWAY BETWEEN TWO OF THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE SUM OF THE FLOW RATINGS OF THE COVERS/GRATES SHALL E AT LEAST TWICE THE SYSTEM'S MAXIMUM FLOW RATE. THREE-OR-MORSUCTION OUTLET ARRANGEMENTS NOTES: 1. ALL COVERS/GRATES SHALL COMPLY WITH ANSI/ASME Al 12.19.8 -LATEST, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, WADING POOLS, SPAS AND HOT TUBS." RECOMMENDED: GRATE S SHOULD BE INSTALLED WITH SUFFICIENT OPEN AREA TO ENSURE A MAXIMUM VELOCITY OF 1.5 FT/S THROUGH THE GRATE(S). 2. SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH ANSI/APSP-7, LATEST. THE FOLLOWING METHODS TO AVOID ENTRAPMENT ARE IN ACCORDANCE WITH ANSI/APSP-7: A) SURI ACE SKIMMING OR '• OVERFLOW SYSTEMS THAT PROVIDE 100% OF THE REQUIRED SYSTEM FLOW; 8)DU SUCTION OUTLET SYSTEMS; C) THREE -OR -MORE SUCTION OUTLET SYSTEMS; D) SINGLE UNBLOCKABL = SUCTION OUTLET SYSTEMS; E) SINGLE OUTLET SWIM JET SYSTEMS (TESTED AND LISTED AS CONFORI AING TO ASME/ANSI Al 12.19.8); F) SINGLE OUTLET - ALTERNATIVE SYSTEMS (IN ACCORDANCE WITH ANSI /ASME Al 12.19.8, -LATEST d AND ASTM F2387-04); G) GRAVITY FLOW TO A VENTED COLLECTORTANK; H) OUTLET SUMPS IN SERIES; 1) OR OTHER MEANS THAT MEET THE INTENTS AND REQUIREMENTS OF ANSIIAPSP-7 AND S APPROVED BY THE AUTHORITY HAVING JURISDICTION. { 3. BRANCH SUCTION PIPING (DEFINED AS THE PIPING SERVING THE SUCTION OUTLETS)SHALL BE SIZED TO 'I ALLOW MAXIMUM VELOCITY OF SIX (6) FEET PER SECOND WHEN ONE OF A PAIR IS E LOCKED. ALL OTHER SUCTION PIPING SHALL BE SIZED TO ALLOW MAXIMUM VELOCITY OF EIGHT (8) FEET PER SECOND. 4. POOLS OR SPAS SHALL NOT BE OPERATED IF SUCTION OUTLET GRATE IS MISSING, BROKEN, OR LOOSE. 5. SUCTION INLETS SHALL BE PLUMBED SUCH THAT WATER IS DRAWN THROUGH THE SIMULTANEOUSLY THROUGH A COMMON LINE TO THE PUMP. 6. SUCTION OUTLET PORT MUST BE SAME DIAMETER OR LARGER THAN SUCTION PIPE EXITING OUTLET. 7. FIELD BUILT SUMPS SHALL BE CONSTRUCTED SUCH THAT THE OPENING OF THE StJ CTION PIPE WILL BE NO CLOSER THAN 1.5 TIMES ITS INSIDE DIAMETER FROM THE BOTTOM OF THE COVER! 3RATE OR SUCH THAT THE SUMP IS OF THE DESIGN SPECIFIED BY THE COVER/GRATE MANUFACTURER TO CO 4TROL FLOW THROUGH THE OPEN AREA OF THE COVER/GRATE. III SEE NOTE 1 BELOW 2" 90" BEND (TYP. VELOCITY = 6 FT / 5 2" TEE OF 2) SCH 40 SCH 80 SUCTION PIPE MAX FLOW MAX FLOW 12" AIR GAP (MIN.) SEE'^ JJJ DIAMETER (GPM) (GPM) NOTE \� 2^ 63 55 MAXIMUM UNDERWATER — LENGTH OF VENT PIPING: 30 FEET FROM TEE ON SUCTION PIPING TO AIR GAP SUCTION OUTLET---___,+ DEBRIS OUTLET MOUNTED IN POOL FLOOR CIRCULATION LINE TO LEAF CANISTER / RECIRCULATION PUMP MINIMUM PIPE LENGTH 18" NOTE: 1, ONE OF THE FOLLOWING OPTIONS IS REQUIRED BETWEEN THE DEBRIS SUCTION OUTLET AND THE PUMP: A) ONE (1) ADDITIONAL SUCTION OUTLET WITH A LILTED COVER/GRATE LOCATED A MINIMUM OF 18" FROM THE TEE IN THE SUCTION LINE TO THE PUMP(S); B) AN ENGINEERED VENT SYSTEM; C) A LISTED MANUFACTURED SAFETY VACUUM RELEASE SYSTEM. OUTLET SUMPS IN SERIES TO SUCTION PIPING SCREEN VENT TO PROHIBIT INSECT ENTRY OR CLOGGING. LABEL VENT AS FOLLOWS: "POOL SAFETY DEVICE - DO NOT HANDLE" VENT PIPING 90 79 138 124 238 215 540 488 VENT LINE DETAIL OFFICE COPY PIAN EXPIRES ONE TW FROM THS SIGNATURE DATE OR 7118 SPFSCIIVB DATE OF A MAJOR FLORIDA RUHMING CODS CHANGE WHICHEVER IS SOONER Tow Certificate of Authority Ne. 28177 4337 PABLO OAKS COURT, SUITE 101 JACKSONVILLE, FL 32224 904-223-9773 FAX: 866-832-9236 pi/q/ 1 i % IIII%IIIiNs",1111%l111MN1111% IIII NO FOOTER 1. DETAIL IS BASED DN NO SURCHARGE BEHIND THE TURNDOWN AND GROUND AWAY FROM TURNDOWN IS LEVEL (>410 1). TURNDOWN IV AY ABUT RIBBON FOOTER AND BE TIED INTO FOOTER IF APPROPRIATE, WITH #3 REBAR. 2. TURNDOWN SHALL BEAR ON ROCK, CLEAN SAND OR STRUCTURALLY SOUND SOIL (> 1,500 PSF) THAT SHALL BE TO #3 BAR CONTINUOUS COMPACTED 3. ALL REINFORCINI BAR CONTINUOUS 4. CONCRETE SHALL CONTAIN FIBER MESH AND HAVE A 28 DAY STRENGTH OF 2,500 PSI. 5. ALL CONSTRUCT ON TO CONFORM TO FLORIDA BUILDING CODE, BUILDING 2007, FLORIDA BUILDING CODE, RESIDENTIAL 2007 TOGETHER REFER TO CONT 1 #3 BAR 4" CONCRETE DECKVERTICALLY 1 #3 BAR @ PAVER BRICK 8" VERTICALLY @ 36" ON CENTER 436, ON CENTER • `v CV N O COMPACTED 4'OR Q COMPACTED N 6 MATERIAL • FLATTER MATERIAL a OR •' r po%� . A. B=9"- 1 B" 14TIN FINISHED GRADE NOTEw 1 #5 REBAR CONTINUOUS '4 FINISHED CO — 3/ax A GRADEB A" to OLD GROUND OLD GROUND 4"0 4" 0 PILASTER EVERY 5' WITH 1 #3 REBAR 5' WITH 1 #3 REBAR PAVER DECK TURNDOWN CONCRETE DECK TURNDOWN IIII%IIIiNs",1111%l111MN1111% IIII NO FOOTER 1. DETAIL IS BASED DN NO SURCHARGE BEHIND THE TURNDOWN AND GROUND AWAY FROM TURNDOWN IS LEVEL (>410 1). TURNDOWN IV AY ABUT RIBBON FOOTER AND BE TIED INTO FOOTER IF APPROPRIATE, WITH #3 REBAR. 2. TURNDOWN SHALL BEAR ON ROCK, CLEAN SAND OR STRUCTURALLY SOUND SOIL (> 1,500 PSF) THAT SHALL BE TO PROVIDE OPTIMUM BEARING CAPACITY AND PREVENT SETTLING OR SHIFTING. COMPACTED 3. ALL REINFORCINI 3 STEEL IS TO CONFORM TO ASTM 615 GRADE 40. 4. CONCRETE SHALL CONTAIN FIBER MESH AND HAVE A 28 DAY STRENGTH OF 2,500 PSI. 5. ALL CONSTRUCT ON TO CONFORM TO FLORIDA BUILDING CODE, BUILDING 2007, FLORIDA BUILDING CODE, RESIDENTIAL 2007 TOGETHER REFER TO CONT NITH LATEST REVISIONS. CTOR'S PLAN ON FILE WITH THE BUILDING DEPARTMENT FOR DETAILS ON TURNDOWN LOCATION. 6. 7. IF THE TURNDOIA N DOES NOT EXTEND INTO THE OLD GROUND, A 4"0 PILASTER WILL BE REQUIRED EVERY 5 FEET THAT WILL BE EITHER FEET INTO THE GROUND OR TO 6" INTO THE INDIGENOUS MATERIAL, WHICHEVER IS DEEPER. THE PILASTER WILL H AVE A #3 REBAR TIED INTO THE #5 REBAR IN THE BASE OF THE VERTICAL POUR 1111%1111\ IIII%IIII IIIININ CONTINUOUS I\IIII%IIID 1 #5 BAR__, 1111%1111: IIIIIIII FOOTER PAVER BRICK COMPACTED n • MATERIAL .. • ..,'. 4. •• d_ ALTERNATE PAVERS ON TURNDOWN SWALE FOR 1 #3 BAR DRAINAGE 8" VERTICALLY @ 36" ON CENTER A. a , 1 #5 REBAR CONTINUOUS •' .a. ALTERNATE PAVER LOCATION B. A DECK TURNDOWN IS NOT INTENDED TO BE A SUBSTITUTE FOR A RETAINING WALL. IF THE VERTICAL D\DIMENSION FROM THE TOP OF THE CONCRETE DECK TO THE OLD GROUND REACHES 22.5" (FOR A 12" TURNDOWN) OR 33" (FOR AN 18" TURNDOWN) OR 43.5" (FOR A 24" TURNDOWN) FOR MORE THAN 20% OF THE TURNDOWN LENGTH OR THE FINISHED GRADE SLOPE EXCEEDS 4 FEET HORIZONTALLY TO 1 FOOT VERTICALLY, ATURNDOWN SHOULD NOT BE USED. 9. FOR A PAVER DECK, IF THE VERTICAL DIMENSION FROM THE TOP OF THE DECK TO THE OLD GROUND REACHES 30" (FOR A 12^ TURNDOWN) 36" (FOR AN 18" TURNDOWN) OR 42" (FOR A 24" TURNDOWN) FOR MORE THAN 20% OF THE TURNDOWN LENGTH OR IF THE FINISHED GRADE SLOPE EXCEEDS 4 FEET HORIZONTALLY TO 1 FOOT VERTICALLY, A TURNDOWN SHOULD NOT BE USED. 10. IF A SCREEN ENCLOSURE IS TO BE INSTALLED ON TO OF THE TURNDOWN, THE SWIMMING POOL CONTRACTOR MUST COORDINATE ATTACHMENT OF THE SCREEN ENCLOSURE TO THE TURNDOWN WITH THE SCREEN CONTRACTOR. DECK TURNDOWNS 1111%1111\ 11111111 IIII\Illi%IIIPEI MINKCONTINUOUS D MOO I I HMO I I INot IIII FOOTER FOOTER NOTES: GRADE 12" 1. FOOTER SHALL BEAR ON ROCK, CLEAN SAND 01 Z STRUCTURALLY SOUND SOIL I I I VIA I 11 `" (>1,500PSI) THAT SHALL BE COMPACTED TO PRI NIDE OPTIMUM BEARING CAPACITY TO PREVENT SETTLING. 2. CONCRETE SHALL HAVE A 28 DAY STRENGTH O 2,500 PSI WITH FIBER MESH 2 #5 BAR OR 6x6-10x10W W MESH. CONTINUOUS 3. 3 #3 BARS IS EQUIVALENT TO 1 #5 BAR. 4. AN ALTERNATIVE TO A CONCRETE DECK IS BRICK PAVERS PLACED EITHER OVER THE TOP OF THE FOOTER OR ABUTTINGI HE FOOTER. 12" X 12" FOOTER 5. IF A SCREEN ENCLOSURE IS TO BE INSTALLED, THE SWIMMING POOL CONTRACTOR MUST COORDINATE CONSTRUCI ION OF ANY REQUIRED FOOTER WITH THE SCREEN CONTRACTOR. TYPICAL FOOTER DETAILS I PIAN E W= ONE YEAR FROM THS SIGNATURE DATE OR THE 9117317M DATE OF A MOOR FLORIDA DUDDING CODS CHANGE RHICMM IS SOONER Certificate of Authority No. 28177 4337 PABLO OAKS COURT, SUITE 101 JACKSONVILLE, FL'a2224 904-223-9773 FAX: 1166-832-9236 7 1✓ NAL ENGINEER NOTE: B—a/a"xA OFFICE COPY RESIDENTIAL SWIMMING POOL DECK AND FOOTER DETAILS THE BATTS COMPANY CPC037046 - CGC055163 1602 NORTH 3rd STREET JACKSONVILLE BEACH, FL 32250 (904) 246-2455 (904) 249-0457 A C DWG. BY: RRW 4 NOT TO SCALE SHEET OF 5 APPROVED BY: JEL `v i N N . m .a. ALTERNATE PAVER LOCATION B. A DECK TURNDOWN IS NOT INTENDED TO BE A SUBSTITUTE FOR A RETAINING WALL. IF THE VERTICAL D\DIMENSION FROM THE TOP OF THE CONCRETE DECK TO THE OLD GROUND REACHES 22.5" (FOR A 12" TURNDOWN) OR 33" (FOR AN 18" TURNDOWN) OR 43.5" (FOR A 24" TURNDOWN) FOR MORE THAN 20% OF THE TURNDOWN LENGTH OR THE FINISHED GRADE SLOPE EXCEEDS 4 FEET HORIZONTALLY TO 1 FOOT VERTICALLY, ATURNDOWN SHOULD NOT BE USED. 9. FOR A PAVER DECK, IF THE VERTICAL DIMENSION FROM THE TOP OF THE DECK TO THE OLD GROUND REACHES 30" (FOR A 12^ TURNDOWN) 36" (FOR AN 18" TURNDOWN) OR 42" (FOR A 24" TURNDOWN) FOR MORE THAN 20% OF THE TURNDOWN LENGTH OR IF THE FINISHED GRADE SLOPE EXCEEDS 4 FEET HORIZONTALLY TO 1 FOOT VERTICALLY, A TURNDOWN SHOULD NOT BE USED. 10. IF A SCREEN ENCLOSURE IS TO BE INSTALLED ON TO OF THE TURNDOWN, THE SWIMMING POOL CONTRACTOR MUST COORDINATE ATTACHMENT OF THE SCREEN ENCLOSURE TO THE TURNDOWN WITH THE SCREEN CONTRACTOR. DECK TURNDOWNS 1111%1111\ 11111111 IIII\Illi%IIIPEI MINKCONTINUOUS D MOO I I HMO I I INot IIII FOOTER FOOTER NOTES: GRADE 12" 1. FOOTER SHALL BEAR ON ROCK, CLEAN SAND 01 Z STRUCTURALLY SOUND SOIL I I I VIA I 11 `" (>1,500PSI) THAT SHALL BE COMPACTED TO PRI NIDE OPTIMUM BEARING CAPACITY TO PREVENT SETTLING. 2. CONCRETE SHALL HAVE A 28 DAY STRENGTH O 2,500 PSI WITH FIBER MESH 2 #5 BAR OR 6x6-10x10W W MESH. CONTINUOUS 3. 3 #3 BARS IS EQUIVALENT TO 1 #5 BAR. 4. AN ALTERNATIVE TO A CONCRETE DECK IS BRICK PAVERS PLACED EITHER OVER THE TOP OF THE FOOTER OR ABUTTINGI HE FOOTER. 12" X 12" FOOTER 5. IF A SCREEN ENCLOSURE IS TO BE INSTALLED, THE SWIMMING POOL CONTRACTOR MUST COORDINATE CONSTRUCI ION OF ANY REQUIRED FOOTER WITH THE SCREEN CONTRACTOR. TYPICAL FOOTER DETAILS I PIAN E W= ONE YEAR FROM THS SIGNATURE DATE OR THE 9117317M DATE OF A MOOR FLORIDA DUDDING CODS CHANGE RHICMM IS SOONER Certificate of Authority No. 28177 4337 PABLO OAKS COURT, SUITE 101 JACKSONVILLE, FL'a2224 904-223-9773 FAX: 1166-832-9236 7 1✓ NAL ENGINEER NOTE: B—a/a"xA OFFICE COPY RESIDENTIAL SWIMMING POOL DECK AND FOOTER DETAILS THE BATTS COMPANY CPC037046 - CGC055163 1602 NORTH 3rd STREET JACKSONVILLE BEACH, FL 32250 (904) 246-2455 (904) 249-0457 A C DWG. BY: RRW 4 NOT TO SCALE SHEET OF 5 APPROVED BY: JEL I 1 1 I I I TRANSFORMER REQUIRED FOR LOW -VOLTAGE INSTALLATIONS ONLY ............................\ ////////////////////A//////.%/////////%%%%%� 300 WATT3'MIN. FROM INSIDE WALL IGHTBONDING CONDUCTOR.wimmom Z" 1 i 1 j REFER TO j NOTE 1 R T 1 I 1 1 1 1 BONDING GRID. REFER TO NOTE #6 JUNCTION BOX �r 4' MIN. I IIMMING POOL COPPER WIRE PANEL SPST TOGGLE SWITCH DISCONNECT 12 V TRANS. 3 #121N y2" COND. 12V/ 30OW WITH LOW WATER CUT-OFF OR 120 VAC W/ GFCI PER NEC ELECTRICAL DIP SERVICE PANEL NEU PUMP MOTOR GROUND NEUTRAL BAR TRANSFOF 3CONDUCTOR t H -N -G #8 BOND TO STRUCTURAL STEEL %_ GROUND BAR CONTROL PANEL TYPICAL GRO ALL ELECTRICAL SHALL CONFORM WITH ART 680 NEC LATEST BOND ALL SHEATHED CABLES, RACEWAYS, METAL PIPING AND ALL FIXED METAL PARTS NOT SEPARATED BY PERMANENT BARRIER, IF WITHIN 5 FT HORIZONTALLY FROM WATER, 12 FT VERTICALLY OF MAX WATER LEVEL. S INCOMING POWER SUPPLY POOL LIGHT BAR GROUND FLEXIBLE CORD GROUNDING TERMINAL `- #8 BOND TO #S BO D 1N STRUCTURAL STEEL PVC C NDUIT SCHEMATIC LADDER, HAND RAIL,' DIVING BOARD, ETC... ENERGY EFFICIENCY NOTES: 1. TIME SWITCHES SHALL BE INSTALLED TO CONTROL SWIMMING POOL HEATERS AND PUMPS THAT CAN AUTOMATICALLY TURN THE HEATERS AND PUMPS OFF AND ON ACCORDING TO A PRESET SCHEDULE. EXCEPTIONS. 1.a. WHERE PUBLIC HEALTH STANDARDS REQUIRE 24-HOUR PUMP OPERATION t.b. WHERE PUMPS ARE REQUIRED TO OPERATE SOLAR -AND WASTE -HEAT RECOVERY POOL SYSTEMS 1.c. WHERE PUMPS ARE POWERED EXCLUSIVELY FROM ONSITE RENEWABLE GENERATION 2. HEATED SWIMMING POOLS AND INGROUND PERMANENTLY INSTALLED SPAS SHALL BE EQUIPPED WITH A VAPOR -RETARDANT COVER ON OR AT THE WATER SURFACE OR A LIQUID COVER OR OTHER MEANS PROVEN TO REDUCE HEAT LOSS. EXCEPTION: OUTDOOR POOLS DERIVING OVER 70% OF THE ENERGY FOR HEATING FROM A SITE -RECOVERED ENERGY OR SOLAR ENERGY SOURCE COMPUTED OVER AN OPERATING SEASON. 3. POOL FILTRATION PUMP MOTORS SHALL MEET THE FOLLOWING REQUIREMENTS: 3.a. POOL PUMP MOTORS SHALL NOT BE SPLIT -PHASE, SHADED POLE OR CAPACITOR START INDUCTION RUN TYPES 3.b. POOL PUMPS AND POOL PUMP MOTORS WITH A TOTAL HORSEPOWER (HP) OF GREATER THAN OR EQUAL TO 1 HP SHALL HAVE THE CAPABILITY OF OPERATING AT TWO OR MORE SPEEDS. THE LOW SPEED SHALL HAVE A ROTATION RATE OF NO MORE THAN } OF THE MOTOR'S MAXIMUM ROTATION RATE. 3.c. POOL PUMPS MOTOR CONTROLS SHALL HAVE THE CAPABILITY OF OPERATING THE POOL PUMP AT A MINIMUM OF TWO SPEEDS. THE DEFAULT CIRCULATION SPEED SHALL BE THE RESIDENTIAL FILTRATION SPEED WITH A HIGHER SPEED OVERRIDE CAPABILITY FOR A TEMPORARY PERIOD NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS. EXCEPTION: SOLAR POOL HEATING SYSTEMS SHALL BE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE SOLAR HEAT GAIN. 4. HYDRAULIC SYSTEMS FOR NEW POOLS MUST BE DESIGNED IN ACCORDANCE WITH APSP-15, `AMERICAN NATIONAL STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY." TO GROUND FAULT CIRCUIT INTERRUPTER THEN TO POWER SOURCE WITH TRANSFORMER 4' MIN. JUNCTION BOX RIGID, IMC OR NON METALLIC CONDUIT BRASS OR NON METALLIC Nv CONDUIT OR APPROVED EQUIVALENT z_ UNDERWATER LIGHTS SHALL BE NEC. APPROVED AND SHALL FEATURE STAINLESS STEEL FORMING m SHELL WITH BRASS MOUNTING RING. SHELL SHALL HAVE A 1" NPT CONDUIT WITH OPENING PACKING GLAND. LIGHT SHALL BE HOUSED 1N A STAINLESS STEEL ENCAPSULATION BOLTED TO A CHROME PLATED FACE RING FOR COMPRESSING OF A 360 DOUBLE WALL SYNTHETIC GASKET. SS LIGHT FIXTURE & NICHE W/ COMPRESSION HUB & —� LED LAMP, 30OW/12V LAMP OR 120 VAC W/ GFCI PER NEC #8 AWG PRESSURE GROUND CONNECTOR TO COMMON BONDING WITH REINFORCING STEEL OR PLUMBING JUNCTION BOX (IF USED) POOL LIGHT DETAIL TRANSFORMER iC POOL LIGHT HEATER CASE POOL CONTROL METAL CONDUITS REINFORCING PANEL OR PIPING SYSTEM STEEL HI o III 1 � PUMP MOTOR--\ I p TYPICAL BONDING SCHEMATIC NOTES: 1. GROUND AND BOND ALL POOLS AND RELATED EQUIPMENT IN ACCORDANCE WITH NEC ARTICLES 250 AND 680. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO ENSURE THAT ALL METALLIC PARTS OF THE POOL STRUCTURE, INCLUDING THE POOL SHELL AND DECK REINFORCING BARS AND ALL OTHER METAL PARTS ARE BONDED PER NEC ARTICLE 250 AND 680. BOND TOGETHER REINFORCING BARS USING STEEL TIE WIRES. BOND ALL METAL PARTS TO POOL REINFORCING BARS USING #8 AWG COPPER WIRES. THESE METAL PARTS INCLUDE, BUT ARE NOT LIMITED TO LADDERS, RAILINGS, PIPING, CONDUIT, METAL DOOR FRAMES AND METAL PARTS WITHIN 5' OF -INSIDE WALL OF POOL. CONNECTION SHALL BE EXOTHERMIC WELD, LISTED PRESSURE CONNECTORS OR CLAMPS AS APPLICABLE. GROUND STEEL COLUMNS (I.E. FOR TOWERS OR SLIDES) PER NEC ARTICLE 250 AND 680 AND NFPA 780. IF REINFORCING BARS ARE ENCAPSULATED WITH A NON CONDUCTIVE COMPOUND, CONTACT ENGINEER BEFORE PROCEEDING. 2. THIS ELECTRICAL INSTALLATION SHALL MEET ALL REQUIREMENTS OF NEC ARTICLES 250 AND 680. IN ACCORDANCE WITH THIS, UNDERGROUND WIRING SHALL NOT BE PERMITTED UNDER THE POOL OR WITHIN 6 HORIZONTALLY FROM THE INSIDE WALL OF THE POOL UNLESS THIS WIRING IS NECESSARY TO SUPPLY POOL EQUIPMENT PERMITTED BY NEC ARTICLE 680. ALL RECEPTACLES SHALL BE LOCATED AT LEAST 10' FROM THE INSIDE WALL OF POOLS. ALL RECEPTACLES WITHIN 20' OF THE POOL SHALL HAVE GFCI PROTECTION. ADDITIONALLY, ALL UNDERWATER LIGHTING SHALL BE GFCI PROTECTED. MOUNTING HEIGHT FOR ANY LIGHT FIXTURES SUSPENDED OVER POOLS SHALL BE NOT LESS THAN 12' ABOVE MAXIMUM WATER LEVEL. 3. IF APPLICABLE, PROVIDE #12 AWG CONDUCTORS AND GROUND FOR 12V UNDERWATER LIGHTING CIRCUITS LESS THAN 8' IN LENGTH. FOR 12V CIRCUITS V TO 15' 1N LENGTH, PROVIDE #8 AWG CONDUCTORS AND GROUND. FOR 12V CIRCUITS GREATER THAN 16, BUT LESS THAN 25 IN LENGTH, PROVIDE #6 AWG CONDUCTORS AND #6 GROUND. NO 12V CIRCUIT SHALL BE MORE THAN 25' IN LENGTH. 4. ELECTRICAL CONTRACTOR SHALL INSTALL NO FEWER THAN ONE 125 -VOLT 15- OR 20 -AMPERE RECEPTACLE ON A GENERAL PURPOSE BRANCH CIRCUIT. RECEPTACLE SHALL BE LOCATED NOT LESS THAN 10 FT. FROM AND NOT MORE THAN 20 FT. FROM THE INSIDE WALL OF THE POOL. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 FT. 6 IN. ABOVE THE FLOOR, PLATFORM, OR GRADE LEVEL SERVING THE POOL (NOT APPLICABLE TO INDOOR POOLS WHERE COMPLIANT RECEPTACLES ARE AVAILABLE). 5. RECIRCULATION PUMP SHALL BE ELECTRICALLY INTERLOCKED WITH CHEMICAL EQUIPMENT, IF APPLICABLE. 6- AN EQUIPOTENTIAL COMMON BONDING GRID IS REQUIRED FOR ALL PAVED WALKING SURFACES WITHIN THREE FEET OF THE INSIDE WALLS OF THE POOL AND/OR SPA FOR THE ENTIRE POOL PERIMETER. THE BONDING GRID MAY BE COMPOSED OF STEEL REINFORCING RODS (REBAR), OR #8 BARE, SOLID COPPER CONDUCTORS. 6 X 6 X 10 WELDED WIRE FABRIC (MESH) IS ACCEPTABLE WHEN PROPERLY INSTALLED ON CHAIRS AND EACH SECTION IS CLAMPED WITH APPROPRIATE LISTED DEVICES AND/OR #8 SOLID COPPER JUMPERS. THE BONDING GRID MAY NOT BE INSTALLED DIRECTLY IN EARTH CONTACT OR WITHOUT PROPER COVER. THE INSTALLATION MUST BE IN ACCORDANCE WITH 680.26(C), NATIONAL ELECTRIC CODE (NEC) - LATEST AND FLORIDA BUILDING CODE 2010 W/ LATEST AMENDMENTS. 7. THE FOLLOWING IS AN ACCEPTABLE ALTERNATIVE TO THE BONDING GRID DEFINED IN NOTE #6, ABOVE: AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUBGRADE AND 18 INCHES TO 24 INCHES FROM INSIDE WALL OF THE SWIMMING POOL OR SPA. THIS IS DEFINED A PERMISSIBLE ALTERNATIVE OR EQUIVALENT TO COMPLIANCE WITH FBC. 26(C) OF0�m5pcopy Y REFERENCE WITHIN FBC. PIAN ESPIRBS ONE YEARFROM THE SIGNATURE DATE OR THE EFFECM DATE OF A YA70R FLORIDA BUILDING CODE CHANGE WHICHEVER IS SOONER. aim Certificate of Authority No. 28177 4337 PABLO OAKS COURT, SUITE 101 JACKSONVILLE, FL 32224 904-223-9773 FAX: 866-832-9236 t 7 411�I I-. PROFESSIONAL ENGINEER RESIDENTIAL SWIMMING POOL ELECTRICAL NOTES AND DETAILS THE BATTS COMPANY CPC037046 — CGC055163 1602 NORTH 3rd STREET JACKSONVILLE BEACH, FL 32250 (904) 246-2455 (904) 249-0457 DWG_ By: RRW NOT TO SCALE SHEET 5 OF 5 APPROVED BY: EL POOL SHAPE 2 SIZE 3 DEPTHS 4 CAPACITY 9700 94( 5 STEPS BENCH ES 6 SWIMOUT 7SUNSHELF 8 HANDRAIL(Sl Q, ARARRA1L(S) n 29 LEAF SKIMMER WALL BRUSH TEST KIT HOSE POLE START-UP GHEMiCALS VACUUM 30' SPA INFORMATION CONCRETE ` --- 6R,"3eo p4 a ANSI/ASP-7 2006 SPECIFIES THREE METHODS FOR DETERMININ13 THE MAXIMUM SYSTEM FLOW RATE. THE FOLLOWING SIMPLIFIED TDH CALCULATION IS ONE OF THE METHODS SPECIFIED. SIMPLIFIED MAXIMUM SYSTEM FLOW RATE: OFFICE cv- MINIMUM FLOW RATE REQUIRED: 35 GPM PER SKIMMER 1. CALCULATE POOL VOLUME: _3& X N Q X 7. (GAL./CUBIC FOOT) (SURF. AREA) (AVG. DEPTH) (VOL. IN GAL:) 2. DETERMINE PREFERRED TURNOVER TIME IN HOURS: A X60 (MIN./HR.)= _ 3toO (H( URS) (TURNOVER IN MIN.) 3. DETERMINE MAX FLOW RATE: 94 f- l o' _ _17 + G % (VOL. IN GAL.) (TURNOVE MINS.) (POOL FLOW RATE) (FEATURE FLOW RATE) (SYSTEM FLOW RATE) 4. SPA JETS:_ X /S' GPM PER JET = FLOW RATE (NO. OF JETS) (JET FLOW) (TOTAL JET LOW RATE) (FOR SINGLE PUMP POOUSPA COMBO, USE THE HIGHER OF NO.3 OR NO.4 IN THE FOLLOWING CALCULATIONS FOR THE POOL & SPA) DETERMINE PIPE SIZES: BRANCH PIPING TO BE J INCH TO KEEP VELOCITY @ 6 FPS MAX. AT _/ �� GPM MAXIMUM SYSTEM FLOW RATE. TRUNK PIPING TO BE 2 INCH TO KEEP VELOCITY @ 8 F S. MAX. AT �L GPM MAXIMUM SYSTEM FLOW RATE RETURN PIPING TO BE _�_ INCH TO KEEP VELOCITY @ 1 FPS MAX. AT L6 3 GPM MAXIMUM SYSTEM FLOW RATE DETERMINE SIMPLIFIED TDH: 1. DISTANCE FROM POOL TO PUMP IN FEET: qO 2. FRICTION LOSS (IN SUCTION PIPE), IN J INCH PI 3. FRICTION LOSS (IN RETURN PIPE) IN 2 _INCH PII 4. Z_/G X . G y (LENGTH OF SUCT. PIPE) (FT OF HEAD / I FT OF PIPE) (TDH 5. G/G X '16 _ (LENGTH OF RETURN PIPE) (FT OF HEAD / t FT OF PIPE) (TDH SELECTED PUMP AND MAIN PUMP SELECTION MAIN DRAIN COVER _ z 114 R fAQf 4 (PUMP UODEL & SIZE IN HP) MODEL) NOTES: MINIMUM SYSTEM FLOW BASED ON MIN. FLOW PER SKIM DETERMINE THE NUMBER AND TYPE OF REQUIRED IN -FLOOR SU TYPE OF COVER F70 O DUAL MAIN. =SUCTION OUTLET f- 3'-► a O O Q MULTI DRAINS SUCTION OUTLET L- I CHANNEL DRAIN CHANNEL DRAIN TDH CALCULATION OPTIONS: FOR EACH PUMP F_ CHECK ONE SIMPLIFIED TOTAL DYNAMIC HEAD (STDH) t COMPLETE STDH WORKSHEET - FILL IN ALL BLANKS TOTAL DYNAMIC HEAD (TDH) COMPLETE PROGRAM OR OTHER CALLS. FILL IN REQUIRED BLANKS ON WORKSHEET & ATTACH CALCULATIONS MAXIMUM FLOW CAPACITY OF THE NEW OR REPLACEMENT PUMP PER 1 FT. @ /3k GPM = . Gy (FROM PIPE FLOW /FRICTIONLOSS CHART) PER 1 FT. @ O J GPM = . 16 (FROM PIPE FLOW/ FRICTION LOSS CHART) �T. PIPE) TDH IN PIPING: ,?l If 'URN PIPE) FILTER LOSS IN TDH (FROM FILTER DATA SHEET): S' NOTES: 1. IF A VARIABLE SPEED PUMP IS USED, USE THE MAX. PUMP FLOW IN CALCULATIONS. 2. FOR SIDE WALL DRAINS, USE APPROPRIATE SIDE WALL DRAIN FLOW AS PUBLISHED BY MANUFACTURER. 3. IN -FLOOR SUCTION OUTLET COVER/GRATE MUST CONFORM TO MOST RECENT EDITION OF ASME/ANSI Al 12.19.8 AND BE EMBOSSED WITH THAT EDITION APPROVAL. 4. PUMP & FILTER MAKE, MODEL AND LOCATION CAN NOT CHANGE WITHOUT SUBMITTING REVISED PLANS AND TDH WORKSHEET. HEATER LOSS IN TDH (FROM HEATER DATA SHEET): S� TOTAL ALL OTHER LOSS: COVER: TOTAL SIMPLIFIED TDH: Z GS'_O _ USING PUMP CURVE FOR SIMPLIFIED TDH & SYSTEM FLOW RATE ,✓/ P 2rr6 L 12Y (SYSTEM FLOW RATE NOT EXCEED APPROVED COVER FLOW RATE) OF 35 GPM. N OUTLETS CGPM MAX. FLOW Is GPM MAX. FLOW Op GPM W/ L s� PORTS FLOW AND FRICTION LOSS PER FOOT SCHEDULE 40 PVC PIPE VELOCI (-FEET PEkM-' OND PIPE SIZE 6 FPS 8 FPS 10 FP 1" 16 GPM 0.14' 21 GPM 0.23' 26 GPM 0.36 1.5" 37 GPM 0.08' 50 GPM 0.14" 62 GPM 0.21' 2" 62 GPM 0.06' 82 GPM 0.19 103 GPM 0.16' 88 GPM 0.05' 117 GPM 0.09' ;146 GPM 0.13' 3" 138 GPM 0.04' 181 GPM -6 -0- 227 GPM 0.10' 4" - 234 GPM 0.03' 313 GPM 0.06 '392 GPM 0.07' 6" 534 GPM 0.02' 712 GPM 0.03' i CHART TOTAL HEAD IN FEET CONVERSION CHART INCHES MERCURY (VACUUM GAUGE) 0 2 1 4 1 6 1 8 110112 114 116 118 0 0.0 2.314.516.8 9.0 11.313.615.8 18.120.3 1 2.3 4,616.8118.320.622.8 9.1 11.4 13.6115.9118.1120.4;22.7 2 4.6 .9 9.11.4 13.7 15.918.2 20.4 22.7 25.0 3 6.9 9.2 11.53.7 16.0 18.2 20.5 22.8 25.0 27.3 4 2 11.513.86. 18.32.522.25.1-127.329.6 5 11.5 1.8.1. 2 .1 27.4 9.6 31.9 1 16.118.4 2 6 2. 2 27. 9.7 1.9 34.2 162 1 .4, 20.7 23.9125.2127.5 29.7 2. 34.3 36.5 18. 2 .0 34. 36.6 38.8 9 20.8 3. 27. .$ 3 . 38.9 41.1 123.126.4.127.6 29.9132.1134.4 .7 41.2 43.4 1 2 - .4 27.7 .9 32.2134.5';7 41. 43.5 45.8 1 27.7 0.0 32.2 34.5 3 .8 9.0 1.3 43.5 45. 48.1 13 30. .5 36. 9.1 41.3 43.6 46.91-48.150.4 14 3 .3 34.8 36. 3 . 41.4 43.6 45.9 48.21W4_ 52.7 15 34. . 39.2 41.4 4 .745.9 48.2 .5 2.7 55.0 16 37.0 39.2 41.50-7 46.0 48. 50.5 52.8 55.0 57.3 17 . 4 43. 46.148.3 50.6 2. 55.1157.4 59. 8 41. 46.1 48.4 .6 52.9 55.1 7.4 7 61.9 19143.9 48.4 .7 2..955.257.4 . 62. .2 2 .2 48.5 .7 .0 64.3 66.5 21 4 .5 . 1 .3166.6168.9 2 1 7. 2. 68.9 71.2 3 .1 5 7.7 71.2 73.5 24 .4 57.7 .062. 64.5 .780.0 71. 73.5175.8' 2 7. . 2.3 . 86.8.89. 71. 73. 5.8 7 .1 2 .1 6 .3 :6 W. 91 71.473.676. 78.180.4 2 .4 64. 66.9169. 71.4 73.7 75.9 78. 80.5 82.7 28 .7 69. 71.5 73.7 76.0 7 80. 82.8 85.0 2 ` .0eg.71.5 73.8 6.0 78. 2 85.187.3. 308 . 71 7 . 76.1 7 0. 8 . 87.4 89.6 31 71. 73.9176.178.4 .7 8 .2 7.4 89.7 92.0 32 .9 76.2178.4 . 83.0 85. 8 . 9.7n2.94.33 7 .2 7 8.3 7. 8 .8 2.6.68 5 0 ' 83.1 5.3 7. 8 . 92. .4 8.935 8 ,9 8 .1 8 .4 87. $9.9 22 94.4 7 01.2 NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE CALCULATED TDH CHART 2 THE FOLLOWING CUT SHEETS ARE INCLUDED PUMP Q HEATER /L l IF CJ FILTER Q THERAPY JETS DATE [? 'MAIN DRAIN [7 WATER FALLS C NTRACTOR SIGNATURE F OTHER JA.v S t TAr r4 a= SWIMMING POOL SPECIFICATION FOR CONTRACTORS PRINTED NAME 70 CONTRACTORS CERT. NO. TO'( 2k4 2Yr-r ,417e,OAI-rrc Zd-*C4!® FG JIM" CONTRACTORS TEL. NO. i IntelliFio r rmance s uMP th 4 Input i 2 VS 3050 and IntellifloVS `-.SVRS 1 RS pump, I to U.S. Standards UL 1081 for Permanently Connected Swimming Pool and 108-01 Liquid Pumps for Swimming Pools Only (Enclosure 3). ition to NSF Standard S0 For Self -Priming Centrifugal Pumps For Swimming Won to Canadian Standards CAN/CSA C22.2 No. 108-01 Liquid Pumps For valuation to ASME/ANSI Standard A.1 12.19.17.2002 Manufactured Safety eQulatory standards. Listing status may change. Always confirm status with lied on spas or hot tubs in Canada. OFFICE COPY IntelliFloO High Performance Pump (Coned) J • Ability to program exact puInN- operationsL�j,ltering, heating, cleaning, spa Lets, water features and more—slashes energy costs up to 90% 30— • SVRS model complies withVirginia Graeme Baker Cd 3450 Safety Act. • Buiit-in diagnostics protect the Intell"o pump from -the most common causes of premature failure— voltage irregularities (SVRS overheating, freeZ1ng, and model includes priming protection as well) • No SVRS calibrations needed. Built-in SVRS cannot be Oct turned off drVlata • Safety lock -out feature (password protected) on se,Wngs i om being SVRS model prevents pump speed ethnology, changed by unauthorized personnel and maxnnum speeds ori SVRS ors (used • Ability to set minimum model so mnteniFlo will only Operatewitiiln the ranges up to 90%. set to help assure safe operation and long life Pool pump detects • Compatible with intelliTouch®, EasYiouce, and SunTouce pool control systems ETL Listed as an ASME A 112. =" • NSF Certified, UL and 19.17.2602 Device th 4 Input i 2 VS 3050 and IntellifloVS `-.SVRS 1 RS pump, I to U.S. Standards UL 1081 for Permanently Connected Swimming Pool and 108-01 Liquid Pumps for Swimming Pools Only (Enclosure 3). ition to NSF Standard S0 For Self -Priming Centrifugal Pumps For Swimming Won to Canadian Standards CAN/CSA C22.2 No. 108-01 Liquid Pumps For valuation to ASME/ANSI Standard A.1 12.19.17.2002 Manufactured Safety eQulatory standards. Listing status may change. Always confirm status with lied on spas or hot tubs in Canada. OFFICE COPY IntelliFloO High Performance Pump (Coned) J 0 20 40 60 80 100 120 140 160 U.S. Gallons per minute 5 10 I5 20 25 30 35 :.. Cubic Meters per hour Ir dimensions, OFFICE COPY sions, see IntelliFlo VF 457 for replacement parts 35 30— 100 Cd 3450 LQ-) 25 - L 80 �. &uu 3 , v 3 `0 20- 060 a � Vis 15 40 =" 10 , 20 5 4 i' 0 0 20 40 60 80 100 120 140 160 U.S. Gallons per minute 5 10 I5 20 25 30 35 :.. Cubic Meters per hour Ir dimensions, OFFICE COPY sions, see IntelliFlo VF 457 for replacement parts Cd 3450 .1560 rpm I'50 rpm 0 20 40 60 80 100 120 140 160 U.S. Gallons per minute 5 10 I5 20 25 30 35 :.. Cubic Meters per hour Ir dimensions, OFFICE COPY sions, see IntelliFlo VF 457 for replacement parts 29 LEAF SKIMMER WALL BRUSH TEST KIT HOSE POLE START-UP CHEMICALS VACUUM 3U SPA INFORMATION CONCRETE SIZE C!� rs DEPTkI „� [EE EMOVAL NT REMOVAL S RICAL HOOK-UP Earn i? y i!mo POOL SPECIFICATIONS A SWIMMING POOL FOR z� 4vc e NED BY l0. s pit co Jkale 1%8" = 1' rrrrr�ryr�rrr..; THE- SAM C-0 General & Swimrhinp P.00t 1602 N. 3rd Street• JaCli3onville^ 32250 POOL SHAPE ! ^E t If 1 2 SIZE 3 DEPTHS 3 f D 1 4 CAPACITY 00 5 STEPS BENCH ES 6 SWIMOUT 7 SUNSHELF 8: HANDRAIL(S 9 . GRABRAIL S t0: LIGHT S -11, TILE ! 43 29 LEAF SKIMMER WALL BRUSH TEST KIT HOSE POLE START-UP CHEMICALS VACUUM 3U SPA INFORMATION CONCRETE SIZE C!� rs DEPTkI „� [EE EMOVAL NT REMOVAL S RICAL HOOK-UP Earn i? y i!mo POOL SPECIFICATIONS A SWIMMING POOL FOR z� 4vc e NED BY l0. s pit co Jkale 1%8" = 1' rrrrr�ryr�rrr..; THE- SAM C-0 General & Swimrhinp P.00t 1602 N. 3rd Street• JaCli3onville^ 32250