Loading...
1799 ATLANTIC BEACH DR - NEW HOME PERMIT �� r 1A CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD T3v v� ATLANTIC BEACH, FL 32233 '!DTI INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0232 Description: new single-family home Estimated Value: 352302.6 Issue Date: 11/14/2017 Expiration Date: 5/13/2018 PROPERTY ADDRESS: Address: 1799 ATLANTIC BEACH DR RE Number: 169505 1500 PROPERTY OWNER: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD HORSHAM, PA 19044 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: TOLL BROS.,INC Address: 250 GIBRALTAR RD STEVEN R MERTEN HORSHAM, PA 19044 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. 01.1w;yt, City of Atlantic Beach APPLICATION NUMBER js 1 Building Department (To be assigned by the Building Department.) r Ate'' - 800 Seminole Road o /_S\I. — -6_,. Atlantic Beach, Florida 32233-5445 1"C� Phone(904)247-5826 • Fax(904)247-5845 P.40109:,. E-mail: building-dept@coab.us Date routed: LIS- r City web-site: http.//www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 11—C1 I AA-land L.. &ALAI VVI • _Department review required Yeses No :ui :in._ 1/ Applicant: 70I ��OS . 3-nC. ' •tannin. : .iii .► J Tree Administrator Project: (1 t A) St ��,-4Q�ik4 hc� C bli or s V �ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Review or Receipt Other Agency Review or Permit Required Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department I First Review: oved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILIING- //- [-0°17 PLANNING &ZONING Reviewed by: Date:2 �7 TREE ADMIN. Second Review: ❑Approved as revised. ❑De /d. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. III Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 iI,J-V.fr, City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road p C � _ X1 '1 �:. Atlantic Beach, Florida 32233-5445 1'��J l.bl J� Phone(904)247-5826 • Fax(904) 247-5845 P..,01 0 E-mail: building-dept@coab.us Date routed: .10 IIS- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: \ 1_c I ,A- -IGi(14, Ottal(. Department review required Yes No :Oil.in._ Applicant: -TO \C, • 4121111 . Tree Administrator Project: n 2 LJ Si n�° ��-PQlrt..tkq V10w Tubli or s V ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed Date:a)G—j_) TREE ADMIN. Second Review: A roved as revised. ❑ pp ['Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ;iL,�� City of Atlantic Beach APPLICATION NUMBER �sA Building Department (To be assigned by the Building Department.) 800 Seminole Road OCT 2 6 2017 p EC 1I- ,. Atlantic Beach, Florida 32233-5445 1`� J Phone(904)247-5826 • Fax(904)247-5845 .;"`jpi �? v E-mail: building-dept@coab.us Date routed: I 0 la-S-- I ("4- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 1-et I A---tk(1k' C- I/Df• _Department review required Yes No P.-- uJdin• Applicant: lb I,V. �fD S . 1(„ - 'tannins : . in.► J -� " Tree Administrator Project: n ILA) Si RV.- a(n.L`u ' o i,n� (ubli or s ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 1fApproved. (Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed byklte/ ..., Date: l0- 17 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 S=-��.re, City of Atlantic Beach APPLICATION NUMBER ,s 1, Building Department (To be assigned by the Building Department.) _,6- 800 Seminole Road OCT 2 6 2017 p ES 11 _ !� �� Atlantic Beach, Florida 32233-5445 W Phone (904)247-5826 • Fax(904)247-5845 I • Larivi E-mail: building-dept@coab.us Date routed: ,I0 I i- I i-3- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 11-ct I A--ttti ic (-- &ALAI ri. _Department review required Yes No " :ui sins._-7 Applicant: -To \,V &.0S . 1\C— • 'tannin. : • i • • J Tree Administrator Project: SLA) S► nV--Par►`l. howi CPublin or s ("Public Uti sties Public Safety Fire Services Review fee $ Dept Signature TC,i Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI TION STATUS Reviewing Department First Review: Approved. Denied. Not applicable (Circle one.) Comments: BUILDING i PLANNING &ZONING (( 3 Reviewed by: ....... Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. [—Not applicable P WORK,q Comments: PUBLIC UTILITIES // — Z- 17 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 OFFICE COPY �:Srs '`%,� Building Permit Application ). City of Atlantic Beach 800 Seminole Road,Atlantic Beach, FL 32233 `r" ' Phone: (904) 247-5826 Fax: (904) 247-5845 1799 Atlantic Beach Drive ��"�a3� Job Address: Permit Number: Legal Description Lot 41 Atlantic Beach Country Club Unit 2, Parcel#67-132 08-2S-29E .151 RE# 169505-1500 Valuation of Work(Replacement Cost)$ 1138.46 Heated/Cooled SF 2684 Non-Heated/Cooled 999 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New home construction. Florida Product Approval# See attached. for multiple products use product approval form Property Owner Information Name: TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904-217-0739 E-Mail btallman@tollbrothers.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) TOLL FL VI, LP Contractor Information Name of Company: Toll Bros., Inc. Qualifying Agent: Steven R. Merten Address 160 Cape May Avenue Oty Ponte-Vedra State FL zip 32081 Office Phone 904-595-5243 Job Site/Contact Number 904-595-5243 State Certification/Registration# CGC1510225 E-Mail btallman@tollbrothers.com Architect Name&Phone# Toll Architecture (407) 248-5800 Engineer's Name&Phone# Lou Pontigo & Associates (904) 242-0908 Workers Compensation Policy #MWC30267702 / Expires: 9/1/2018 _ Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PA ' G TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINAG, CONSULT WITH YOUR LENDER OR AN A •''NEY BEFORE RECORDING YO, '1 ' 'TICE% OF COMMENCEMENT. Aff (Signa ure o'finer or Agent including Contractor) 'ature of Contractor) Signed and s orn to(or affirmed)before me this 3 day of Signed an. sworn to(or affirmed)before me this 3 day of 0C4oi-x✓ , 2011•--117Q- (Signature , by S+&i . Merton_ev_ �,e.fic , Z Di 1 , by S f-V L /L(e/�"u (Signature of Notary) (Signature of Notary) jeloN Notary Public State of Florida /- NV] (TN Notary Public State of Florida Personally Known OR . Melissa Sue Lieberman Personally Known OR Melissa Sue Lieberman [ )Produced Identificati. '�', " My Commission GG 728088 [ ] 9 • My Commission GG 726068 ",;-• Expires 09/18/2021 Produced Identification ocv Expires 09/78/2027 Type of Identification: Type of Identification: ,, r1'%��1 roc. City of Atlantic Beach r� t PUBLIC UTILITIES DEPARTMENT `y s, 1200 Sandpiper Lane Atlantic Beach, FL 32233 ,``j'i~:; (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date /1 - 2 - / 7 Project Address / 7 9 1477A/it) c Yc�}(-0/41 IL)r- Number of Units I Commercial Residential / Multi-Family New Water Tap(s) & Meter(s) 3 Meter Size(s) �r New Irrigation Meter Upgrade Existing Meter from to (size) 3 New Reclaim Water Meter ✓/ Size New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application# 3 17 — 0 2- 2 /0 C ( Water System Development Charge $ I , I Li 0 , Oo Sewer System Development Charge $ (Ir O SO , CX_) Water Meter Only $ I B S-. UC] Reclaim Meter Only $ less U v Water Meter Tap $ Sewer Tap $ Cross Connection $ 50 e ed Other $ TOTAL $ 5 (' / 0, C) (Notes) APPROVED Kayle Moore, P.E. Date rri (1 (t Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED -5(--liw A REVOCABLE ENCROACHMENT PERMIT f jv THIS REVOCABLE ENCROACHMENT PERMIT, issued on this y day of 00-t-p kg_ ,20 ti , by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and TOLL FL VI,LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach Right-of-Way Permit# . This work is generally described as Pavers in the Right-of-Way for the driveway. . Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested,to the following address 1799 Atlantic Beach Drive, Parcel#67-132 08-2S-29E. 151 . • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY, including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of public right-of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any : the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the U ' . /4 Date /C11// 7 Property Owner: St= en erten,Division Sr. Vice President,TOLL FL VI,LP(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF SAINT JOHNS The foregoing instrument was acknowledged this L-1- day of 0 eft)be4— ,20‘1 , by Ste.,M1€1'1? 61 V SVP ,who personally appeared before me and (printed name of Signer) acknowl- iy that he/she signed the instrument voluntarily for the purpose expressed in it. 1 Signature 0 ary Publi , State of Florida Approved/Public Works Department: Personally Known Produced Identification(Type) Scott Wi iams 'r y.� 'ub is Works�or 4d uq, Notary Public State of Florida ' Melissa Sue Lieberman +y:, s� My Commission GG 128088 %,„d' Expires 08118/2021 5 LA4 A RIGHT-OF-WAY/ EASEMENT PERMIT Dr Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 1799 Atlantic Beach Drive Phone 904-595-5243 Permittee `jr\-.(,1JL (teAN) 101 \ !� YOS , 111Email btallmantollbrothers.com Requesting Permission to Construct Pavers in the Right of Way for the driveway. Location (Reference to Cross-Street)Atiantic Beach Drive and Atlantic Beach Court-06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works, any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Stacia Moore (Project Superintendent) located at 237 9th Avenue North,Suite 4,Jacksonville Beach, FL 32250 . • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within 30 days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss, damage and c•: of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights .. •• privileges. • The Director of • • , Works shall be notified twenty-four(24)hours prior to starting work and again immediately upy ••, • etion. / Date (0/ 17 Permittee(signed in p -senc: • ` otary Public) STATE OF FLORIDA,COUNTY OF SAINIIOHNS The foregoing instrument was acknowledged this 4 day of 0 C+oly k. ,2011 , by �4 a.Mel 1 4'I, 1M'/ ' W ,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. ill A Personally Known Sig'7771115% otary Public,State of Florida Produced Identification(Type) eyNotary Public State of Florida • Melissa Sue Lieberman +• My Commission GG 126088 "o,,,er Expires 09/18/2021 DO NOT TE Applica, e Co.es: 2010 FLORIDA BUILDING CODE BELOW OFFICE USE ONLY review Result circle one : Approved Disapproved -A.pprovedw/ Conditions Review Initials/Date: //- C 020/7 • Development Size Habitable Space a 68?9 Non-Habitable 9 9 F • impervious area 4iscella:neous Information )ccupancy Group f--3 ype of Construction V imber of Stories ring District fi 66 x. Occupancy Load Sprinklers Required ad Zone n ditions/Comments: Perm' 34' OFFICE COPY NOTICE OF COMMENCEMENT State of: FLORIDA Tax Folio No. 169505-1500 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 41 Atlantic Beach Country Club Unit 2,67-132 08-2S-29E.151 Address of property being improved: 1799 ATLANTIC BEACH DRIVE,ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 160 CAPE MAY AVE.,PONTE VEDRA,FL 32081 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: Contractor: TOLL BROS.,INC. P�Q � Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 12d Telephone No: 904-595-5243 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN,Division Sr.Vice President Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year fro the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER / Signed: Date: I /)l i 2 Before me this day of in the County of St.Johns, °fate Of Flori.. has p onally appeared Ste,Ut-M sie t t , Q 1V- S t2 VP Doc#2017242565,OR BK 18160 Page 1045, )tary Public at Large,State of Florida,County of ST.JOHNS. Number Pages:1 y commission expires:/0t L.S t I Recorded 10/23/2017 03:02 PM, rsonally Known: �� / or RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL 3duced Identification: COUNTY RECORDING $10.00 Notary Public State of Florida Melissa Sue Lieberman V di My Commission GG 126088 aro. Expires 09/18/2021 OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: Toll Brothers,Inc. Permit# e&S /7- 0 2 3 2. Project Address: 1799 Atlantic Beach Drive,Atlantic Beach,FL 32233 Lot 41 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) O(� 2 3 2017 for the building components listed below as applicable to the building construction project for the permit number listed above. You should contac�"T your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuildina.org_ Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6 Single-FL6506.4 Simpson Door Company Wood Door FL 14487.1 Therma-Tru Fiberglass/Wood Door N/A FL 5262.3 2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251 3. Sectional Clopay Building Products Section Ext.Door +20/-20 PSF FL15279.1/FL15279.3 4.Roll up 5.Automatic 6. Other B. WINDOWS 1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435 2.Horizontal slider PGT 5400 Vinyl Hor.Window +50/-50 FL 1844 3.Casement 4.Double hung 5.Fixed PGT 5400 Vinyl Fixed Window +50/-50 FL 5012 6.Awning 7. Pass-through 8.Projected 9.Mullion PGT Alum/Vinyl Mullions N/A FL 261 10.Wind Breaker 11.Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1 12. Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12 'Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C.PANEL WALL 1.Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4 FL 12098.3; 12098.1; Nichiha Corp. Lap Siding and Shingles N/A 12875.1 2.Soffits/Ceilings James Hardie Building Products,Inc. Soffit Panels N/A FL 13265.1 Nichiha Corp. Soffit Panels N/A FL 12098.4 3.EIFS 4.Storefronts Kawneer Glass Windows Mitred Glass +30/-30 FL 10008.1 5.Curtain walls 6.Wall louvers 7.Glass block 8.Membrane 9.Greenhouse 10.Synthetic Stucco 11.Other D.ROOFING PRODUCTS 1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1 2.Underlayments Woodland Industries,Inc. Felt N/A FL 1814.12 Boral Roofing Roof Underlayment N/A FL 14317.1 3.Roofing fastners 4.Nonstructural metal roof Millennium Metals,Inc. Metal Roofing-M seam N/A FL 5211.3 R6 5.Built-up roofing 6.Modified bitumen . 7.Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing 11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake N/A FL 13714.1 12.Roofing slate 13.Liquid applied roofing 14.Cement-adhesive coats _ 15.Roof tile adhesive 16.Spray applied polyurethane roof 17.Other P11-Deck Walking deck membrane NiA FL 12407.1 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E. SHUTTERS 1.Accordion 2.Bahama 3.Storm panels t()NA n and Country Industries Storm shutters N/A FL 11963 4.Colonial 5.Roll-up 6.Equipment 7.Other - F. STRUCTURAL COMPONENTS 1.Wood connector/anchor Simpson Strong Tie Per engineering 2.Truss plates Alpine Engineered Truss plate conn. Per engineering 3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1 4.Railing 5.Coolers-freezers 6.Concrete admixtures 7.Material 8.Insulation forms 9.Plastics — 10.Deck-roof 11.Wall 12.Sheds 13.Other G.SKYLIGHTS 1.Skylight Sun Tek FGC Skylite FL 2442 2.Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1 7/16"Zip Wall-Structural 1 OSB(roof and wall);manufacturered by Huber Engineered Woods 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector,a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. Brianna Tallman k)i-AAOla (Contractor Name) (Print Name) (Signature) Company Name: Toll Brothers, Inc. Mailing Address: 160 Cape May Avenue City: Ponte Vedra State: FL Zip Code: 32081 Telephone Number: 904 217-0739 Fax Number: Cell Phone Number: 904-405-8969 Email Address: btallman@tollbrothers.com FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Anastasia 2684 Left•SW Builder Name: Toll Brothers,Inc. Street: Lot 41 Atlantic Beach CC Permit Office: Duval ' City,State,Zip: Atlantic Beach ,FL, Permit Number: C'� Owner: Toll Brothers,Inc. Jurisdiction: 261300 U L i 2 3 2017 I Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) C: i 1. New construction or existing New(From Plans) 9. Wall Types(2515.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 2261.70 ft2 • b.Frame-Wood,Adjacent R=13.0 253.50 ft2 3. Number of units,If multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (2684.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2484.00 ft2 6. Conditioned floor area above grade(ft2) 2684 b.Under Attic(Vented) R=19.0 200.00 ft2 • c.N/A R= ft2 I Conditioned floor area below grade(ft2) 011.Ducts R ft2 7. Windows(358.8 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 358 • . a. U-Factor: Dbl,U=0.34 358.75 ft2 SHGC: SHGC=0.27 , b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 42.0 SEER:14.00 SHGC: c. U-Factor: N/A ft2 I SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A •ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 7.551 ft. , Area Weighted Average SHGC: 0.270 14.Hot water systems a.Natural Gas Tankless Cap: 1 gallons • 8. Floor Types (2684.0 sqft.) Insulation Area • EF:0.800 • a.Slab-On-Grade Edge Insulation R=0.0 2684.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat / Total Proposed Modified Loads: 64.62 PASS Glass/Floor Area: 0.134 Total Baseline Loads: 69.09 I hereby certify that the plans and specifications covered by Review of the plans and ;t�`jQ�''OE.ST'ATA:+,, ' this calculation are in compliance with the Florida Energy specifications covered by this ;1�w,.��' a-!1,p Off;.3 Code. �'�,%. _: , calculation indicates compliance " 47S �; :'4 __ • � with the Florida Energy Code. =f•-•,.,001",',4,',.; ,:. '' ,;,O )0411 ere Before construction is completed = d:; 'i PREPARED BY: � ,11,;_ _ ....-e...- :d DATE: _/�-�Z-2��� this building will be inspected for • O•; I; �: s compliance with Section 553.908 Y`. �`�' v, / I hereby certify that this building, as designed,is in compliance Florida Statutes. 4.--p •- ���` ,I with the Florida Energy ode. / / •<<�O� '� '`�r OWNER/AGENT: 4. / A 1 /' LSA BUILDING OFFICIAL: //-6 _a 0l7 /lid- DATE: (O-2-3'f DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 10/2/2017 2:41 PM • EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 , FORM R405-2014 PROJECT Title: Anastasia 2684 Left SW Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2684 Lot# Owner: Toll Brothers,Inc. Total Stories: 1 Block/SubDivislon: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers,Inc. Rotate Angle: 0 Street: Lot 41 Atlantic Beach C Permit Office: Duval Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach , Family Type: Single-family FL, New/Existing: New(From Plans) • Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp • V Design Location TM?Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block/ 2684 26840 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infii ID Finished Cooled Heated 1 Main 2684 26840 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 200 ft 0 2684 ft2 ____ 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 3002 ft2 672 ft2 Medium 0.6 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2684 ft2 N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 38 Blown 2484 ft' 0.11 Wood 2 Under Attic(Vented) Main 19 Blown 200 ft' 0.11 Wood 10/2/2017 2:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V t Orat To wall Type Space g_valuP Ft to Ft In Area P-Values Fraction. Absor (rade% _ 1 SW Exterior Frame-Wood Main 19 9 10 10 0 98.3 ft2 0 0.23 0.6 0 _2 SE Exterior Frame-Wood Main 19 82 2 10 0 821.7 ft2 0 0.23 0.6 0 _ • 3 NE Exterior Frame-Wood Main 19 45 0 10 0 450.0 ft2 0 0.23 0.6 0 _4 NW Exterior Frame-Wood Main 19 82 2 10 0 821.7 ft2 0 0.23 0.6 0 _ 5 SW Garage Frame-Wood Main 13 28 2 9 0 253.5 ft2 0 0.23 0.01 0 _6 S Exterior Frame-Wood Main 19 3 6 10 0 35.0 ft2 0 0.23 0.6 0 j 7 W Exterior Frame-Wood Main 19 3 6 10 0 35.0 ft2 0 0.23 0.6 0 DOORS V # Ornt Door Type Space Storms U-Value Ft Width In FtWidthArea 1 S Insulated Main None .54 3 8 24 ft2 . 2 SW Wood Main None .39 .2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. i / Wall Overhang V -# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 SW 1 Vinyl Low-E Double Yes 0.34 0.27 18.0 ft2 3 ft 4 in 1-ft 0 in None Exterior 5 2 SE 2 Vinyl Low-E Double Yes 0.34 0.27 45.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 3 NE 3 Vinyl Low-E Double Yes 0.34 0.27 128.0 ft2 18 ft2 in 1 ft 0 In None Exterior 5 4 NE 3 Vinyl Low-E Double Yes 0.34 0.27 45.0 ft2 1 ft 4 In 1 ft 0 In Drapes/blinds Exterior 5 • 5 NE 3 Vinyl Low-E Double Yes 0.34 0.27 4.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 6 NW -4 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 7 SW 1 Vinyl Low-E Double Yes ' 0.34 0.27 8.0 ft2 6 ft 4 in 1 ft 0 in None Exterior 5 , 8 NW 4 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 1 ft 4 In 1 ft 0 In None Exterior 5 9 NW 4 Vinyl Low-E Double Yes 0.34 0.27 3.8 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 10 SE 2 Vinyl Low-E Double Yes 0.34 0.27 18.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 11 NE 3 Vinyl Low-E Double Yes 0.34 0.27 4.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 12 NW 4 Vinyl Low-E Double Yes 0.34 0.27 4.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 13 S 6 Vinyl Low-E Double Yes 0.34 0.27 18.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 14 W 7 Vinyl Low-E Double Yes 0.34 0.27 18.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 1 602 ft2 602 ft2 60 ft 9 ft 1 10/2/2017 2:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 • INFILTRATION • # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 3131.3 171.91 323.29 .3425 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 42 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 42 kBtu/hr 1260 cfm 0.7 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation ' 1 Natural Gas Tankless Exterior 0.8 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert# Company Name System Model# Collector Model# Area Volume FEF 1 None None - ft2 DUCTS —Supply-- ---Return— Air CFM 25 CFM25 HVAC# • V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool • 1 Attic 6 358 ft2 Attic 112 ft2 Default Leakage Attic (Default) (Default) 1 1 • TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun [X]Jul X Au X Se Oct ]Nov Dec Heatinf XI Jan f XI Feb [Xj Mar E j Ar f I Maf I Jun E ]Jul t I Augf I Se [ i Oct f X]Nov f X1 Dec Venting [ Jan I Feb X Mar [X Apr [ May [ Jun l Jul Aug [ SepIX Oct [X]Nov [ Dec 10/2/2017 2:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/2/2017 2:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index,the more efficient the home. Lot 41 Atlantic Beach CC, Atlantic Beach , FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 2261.70 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 253.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2484.00 ft2 6. Conditioned floor area(ft2) 2684 b.Under Attic(Vented) R=19.0 200.00 ft2 c.N/A R= ft2 7. Windows" Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.34 358.75 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 358 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency I c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:14.00 '. SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 7.551 ft. • Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14.Hot water systems • Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2684.00 ft2 a.Natural Gas EF:0.8 b.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat E I certify that this home has complied with the Florida Energy Efficiency Code for Building o`"'IHEST ''"� Construction through the above energysavingfeatures which will be installed(or exceeded) .. ATS l•• in this home before final inspection. Otherwise, a new EPL Display Card will be completed = ' . °_V. �'A. based on installed Code compliant features. '",,,. ' �''' "',.ry� Builder Signature: `-6) .A4ju Z Date: 0. 2_? 1"� te.o,. `id i�'r Address of New Home: C �, City/FL Zip: Pt-�-k( IC �i,;�' c., el`� 1-la°l IA�1rih �I 'N•i........:.... ` ,IY 3 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/2/2017 2:42 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 • FORM.R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Lot 41 Atlantic Beach CC Permit Number: Atlantic Beach , FL, MANDATORY REQUIREMENTS See individual code sections for full details. • 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. O R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402,4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. 0 R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. O R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. O R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. • R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system, including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,Including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/2/2017 2:42 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2:1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal:and 2. Be installed at an orientation within 45 degrees of true south. [) R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating, ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 10/2/2017 2:42 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6:1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403:7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. • R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2, Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. ❑ RR404:1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 10/2/2017 2:42 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 • • FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Anastasia 2684 Left SW Builder Name: Toll Brothers,Inc. Street: Lot 41 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. • Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/2/2017 2:42 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 • ' FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Anastasia 2684 Left SW Builder Name: Toll Brothers,Inc. Street: Lot 41 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation . Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. .// Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and /77 framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. Z _ The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently Z attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or ✓/ unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled / by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Z Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be _ air tight, IC rated,and sealed to the drywall. Z Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. V- barrier Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. Z HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have gasketed doors 10/2/2017 2:42 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 II , . FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Anastasia 2684 Left SW Builder Name: Toll Brothers,Inc. Street: Lot 41 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 2684 sq.ft. Cond.Volume: 26840 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R. CFM(50): Single or Multi Point Test Data • HOUSE PRESSURE FLOW: I ELA. EqLA: ACH: ACH(50): SLA: • R402.4:1.2-Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,If installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,If installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, K... ...AZs' performance results demonstrate compliance testing shall be conducted by an :.••• ;, ...,n with Florida Energy Code requirements in approved third party. A written / .:u��= __ ,� accordance with Section R402.4.1.2. t+"` ;,''�� �� o report of the results of the test shall : be signed by the third party /11; : // conducting the test and provided to * .• �r SIGNATURE.. 'IAA r • 9i ,, t. the code official. Y ,,r • Z PRINTED NAME: �"" ""' �� � ��� I "" BUILDING OFFICIAL: DATE: 0 23 • DATE: • 10/2/2017 2:42 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 OFFICE COPY Job: Lot 41 ABCC Project Summary Date: �., J Entire House By: Saldie Guintivano �,Wait McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web'.www.mcgowansac.corn Pro'ect Information For: Steve Merten,Toll Brothers, Inc. , 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: The Anastasia Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 73 °F Inside db 73 °F Design TD 41 °F Design TD 26 °F Daily range M Relative humidity 50 % Moisture difference 65 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 25047 Btuh Structure 23076 Btuh Ducts 4482 Btuh Ducts 5472 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) 0 Btuh Bloer(none) 0 Btuh Piping 0 Btuh Equipment load 29529 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28548 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3 (partial)/1 Pressure/AVF 50 Pa/62 cfm Structure 1332 Btuh Ducts 1290 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2684 2684 Equipment latent load 6237 Btuh Volume(ft') 26975 26975 Air changes/hour 0.01 0.01 Equipment Total Load (Sen+Lat) 34785 Btuh Equiv.AVF (cfm) 5 3 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0420000A0 Cond CH14NB0420000A0 AHRI ref 9162578 Coil FB4CNP042L AHRI ref 9162578 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 30 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.92 Capacity balance point=24°F Backup: Input=9 kW, Output=31046 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsofC' 2017-Oct-0213:00:56 Comfort Builder by Wrightsoft 17.0.23 RSU03444 Page 1 AC ..ilders\Toll Brothers\Anastasia 2684 Left SW.rup Calc=MJ8 Front Door faces:SW y lh-1 � First Floor r I 3••Fun m.,,,,-1 Bedrecm 10x6 14x14 14x6 6.. 12" 8•. 4X8 we hers 4 hi: 8 x 4 1 4x8 4. 4•. 10" 1 , 3"Fan 12 X F Breakfast 7 I 6x10 6 .. I bed I. 12x6 4x8 •. 12x12, 8' Great dean • 12" v0 V O 6x10 6" retreat - .12 x 6 Kitchen •14" 12x12, • ,,,• 24x18 •12x6 16" 8x40x6 8x4 4_ ' 5 4.. Bedroom Bedroom 3 I Pant Nall 1 6x10 • 10x10 6" Bath 2 EEE • RI I\l ... 12x6 18" 3"Fan 10x1.1 / Hall2 1 16" •4- UnTh iu 12" --..------ roe" tJ •.14 x 6 Gat89e. 10x6 12x12 8' 6"_,_ 10" Foyer Study rte, .) — \ r-----3 ,'''/// Job#: Lot 41 ABCC Scale: 1 : 121 Performed by Saldie Guintivano for: McGowan's Heating & Air Conditioni... Page 1 Steve Merten 160 Cape May Ave. 4850 Collins Road Comfort Builder by Wrightsoft Ponte Vedra,Fl 32081 Orange Park,Fl 32073 17.0.23 RSU03444 Phone:(904)217-0739 Fax:(904)814-8173 Phone:904-278-0339 Fax:904-278-0366 2017-Oct-02 13:01:39 www.tollbrothers.com smerten@tollbrothersinc.com www.mcgowansac.com korey@mcgowansac.com ...thers'Anastasia 2684 Left SW.rup Manual S Compliance Report Job: Lot 41 ABCC Date: fry j Entire House By: Saldie Guintivano l McGowan's Heating Sr: Air Conditioning, Inc. 4850 Collins Road,Orange Park,FI 32073 Phone:904-278-0339 Fax.904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.corn Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten©tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 28548 Btuh Entering coil DB: 73.9°F Outdoor design WB: 80.2°F Latent gain: 6237 Btuh Entering coil WB: 61.3°F Indoor design DB: 73.0°F Total gain: 34785 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Sensible capacity: 29110 Btuh 102%of load Latent capacity: 7155 Btuh 115%of load Total capacity: 36265 Btuh 104%of load SHR: 80% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 29529 Btuh Entering coil DB: 72.6°F Indoor design DB: 73.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Output capacity: 32370 Btuh 11d'/a of load Capacity balance: 24 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 9.1 kW 105%of load Temp. rise: 46 °F Meets are all requirements of ACCA Manual S. 2017-Oct-02 13:00:56 ;: wrightsoft' Comfort Builder by Wrightsoft 17.0.23 RSU03444 Page 1 ACS. ...ilders\Toll Brothers 2684 Left SW.rup Calc=MJ8 Front Door faces:SW • Duct System Summary Date: Lot 41 ABCC A �[jGlUl'7It j 4r^n Entire House By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.268/0.122 in H2O 0.268/0.122 in H2O Lowest friction rate 0.074 in/100ft 0.074 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length (TEL) 530 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 2 h 342 14 12 0.136 4.0 Ox 0 VIFx 17.0 180.0 st2 Bedroom 3 h 2208 92 81 0.137 6.0 Ox 0 VIFx 21.0 175.0 st2 Breakfast h 2715 113 72 0.084 7.0 Ox 0 VIFx 58.3 260.0 st4 Dining h 2334 97 94 0.123 7.0 Ox 0 VIFx 33.0 185.0 st6 Foyer h 1759 73 62 0.125 6.0 Ox 0 VIFx 28.7 185.0 st6 Great Room c 2864 66 123 0.089 7.0 Ox 0 VIFx 40.7 260.0 st4 Great Room-A c 2864 66 123 0.111 7.0 Ox 0 VIFx 25.5 215.0 st3 Kitchen c 2460 85 106 0.119 7.0 Ox 0 VIFx 39.9 185.0 st6 Ldry. c 1044 23 45 0.137 5.0 Ox 0 VIFx 16.1 180.0 st2 Master Bath h 2850 118 67 0.074 6.0 Ox 0 VIFx 60.5 300.0 st5 Master Bedroom-A h 4171 173 144 0.075 8.0 Ox 0 VIFx 53.7 305.0 st5 Pantry h 255 11 8 0.124 4.0 Ox 0 VIFx 35.0 180.0 st6 Study h 3422 142 134 0.125 8.0 Ox 0 VIFx 28.8 185.0 st6 bath 3 c 105 3 5 0.105 4.0 Ox 0 VIFx 35.1 220.0 st3 bed 2 c 1431 57 61 0.087 6.0 Ox 0 VIFx 47.2 260.0 st4 hers c 100 3 4 0.075 4.0 Ox 0 VIFx 56.3 300.0 st5 his c 71 2 3 0.087 4.0 Ox 0 VIFx 46.6 260.0 st4 retreat c 1627 63 70 0.108 6.0 Ox 0 VIFx 28.1 220.0 st3 wc-A h 626 26 11 0.074 4.0 Ox 0 VIFx 64.0 300.0 st5 2017-Oct-02 13:00:56 wrightsoft° Comfort Builder by Wrightsoft 17.0.23 RSU03444 Page 1 ACCP ...ilders\Toll Brothers\Anastasia 2684 Left SW.rup Calc=MJ8 Front Door faces:SW Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 689 684 0.074 644 14.0 0 x 0 VinIFIx st2 st5 Peak AVF 320 227 0.074 587 10.0 0 x 0 VinIFIx st4 st4 Peak AVF 558 487 0.074 710 12.0 0 x 0 VinlFlx st3 st1 Peak AVF 1225 1225 0.074 693 18.0 0 x 0 VinIFIx st2 Peak AVF 817 821 0.074 588 16.0 0 x 0 VinIFIx st1 st6 Peak AVF 408 404 0.119 519 12.0 0 x 0 VinIFIx st1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 133 170 131.3 0.093 122 16.0 Ox 0 VIFx rt1 rb5 Ox 0 320 227 166.3 0.074 407 12.0 Ox 0 VIFx rt1 rb2 Ox 0 128 192 143.3 0.085 550 8.0 Ox 0 VIFx rt1 rb3 Ox 0 333 346 130.8 0.094 990 8.0 Ox 0 VIFx rt1 rb4 Ox 0 312 290 107.1 0.114 572 10.0 Ox 0 VIFx Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 913 935 0.074 529 18.0 0 x 0 VinIFIx 2017-Oct-02 13:00:56 r� Wrights_ft' Comfort Builder by Wrightsoft 17.0.23 RSU03444 Page 2 ACCP. ...ilders\Toll Brothers\Anastasia 2684 Left SW.rup Calc=MJ8 Front Door faces:SW Jack i• off Hip 2' Ridge . i• 1111tUILDING i• BCS r COMPONENT SUPPLY,INC, 11 4627 JP HALL BLVD.SUITE 2048 2'-2 g' GREEN COVE 6PRINDS, FL 32043 ❑: 904.297.9390 F: 904.529.1 406 BEARING HEIGHTS NI rica,swimm 91-1 1/811 V////I 1 Cl'-1 1/1311 83-05-00 18-02-00 1 61-11-05 1 3-03-11h. 1 21-1 1/8" • _ ll TOtI —_ __ /il%I/I/',I////.�%////%///:I////.,%////.'i%///',%////.i%////�%///!%///!//I//.'%////.i%///I'.%////.r %H/!I////.////l%///!%////.%////'�I/N/!%////n%////!%///!I a%////%//I'%////:%/.i I'''��/����/��j�j '''� _ V/////i T02!__'NNiN Y \ �,A ■I.I-'I,\ TSS 011 1 1 1 ili 1 -� I=�! These trusses arededas individual building components to be \ I F incor rated into the building design at JosH �11��111�1�1 �■I,I'I��I the specification of the building \ IUI s design Identified on t drawing.The buildinJINNI ,�. li 1 ; esponsible for tempornt bracing of the roof os IHhiIIHHIi'u em and for the overall\ The desi n of the truss II /fiN�_i� support structure including headers, IM 1}t "" ; "i I�, beams,walls,and columns is the Iii , ��, ■I'll1_—J26 responsibility of the building designer. big �y'W///1'///J,r JE.,//// 4.%�A"%////"� For general guidance regarding $ 111 11110 IiuNG11I I ■II"I, 2s bracing,consult"Bracing of Wood $ Trusses"available from the Truss Plate I I I I II �' II I i Institute, ,c D'Onifrio"Br Drive;Madison, ;I INJ2s ATTENTION.TENTI g.MOMM IIM MEM M TTENTIO. $ '� —"_ Refer to truss layout and engineering q111. I _ _ , documents that arrive with delivered �_�' i' II : II � I• �� �� � fieldUusses. - II i ii i 1 i i. i I I 1 I i ii iI i. i� i- i. i iI � Unlesotedotherwise,all beams are�� IJ18byothers.� �il —J16R:son., $IDNDATEI,I � CHEKED By ❑❑/0404/15 i , 'J18 —�J1s • IENT TOLL BROTHERS 4 1I J18 S LIBVI5IDN ATLANTIC BEACH y 1'18 Y DEL ANASFFTA IAT23ELATION O EHE O�� • T22 1 I I 1 I I 1 I 1 1111,11111 - LDT # .- r .- . . . . r . . .- . . . . . r . r �- - r .- r 1 RAS 79.11-00 DATE FIRST FLOOR LAYOUT 041 10/04/2017 SCALE: NTS Bart 14366