Loading...
156 SANDY BEACH LN - NEW HOME PERMIT g1 CITY OF ATLANTIC BEACH 73V, } 800 SEMINOLE ROAD _m_� ATLANTIC BEACH, FL 32233 '"� ;3 IP. INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0233 Description: new single-family attached home Estimated Value: 141800.5 Issue Date: 11/15/2017 Expiration Date: 5/14/2018 PROPERTY ADDRESS: Address: 156 SANDY BEACH LN RE Number: 173414 0190 PROPERTY OWNER: Name: BEACHES HABITAT FOR HUMANITY INC Address: 797 MAYPORT RD ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: 201 MAYPORT CONSTRUCTION MANAGEMENT Address: 2768 STATE RD Al A#701 ATLANTIC BEACH, FL 32233 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. 0,i,\J;4v, City of Atlantic Beach APPLICATION NUMBER 41 P- ' i1 Building Department (To be assigned by the Building Department.) - 800 SeminoleRoad LS'' _o -T �r AtlanticticBeach, 9 Florida 32233-5445 L Phone(904)247-5826 • Fax(904)247-5845 "t0,'tl9% Ia-g l' E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: IS 1O Sar (k re_((fjr1 Ln. De artment review required Yes No uildin9 Applicant: Q 0 l a yn0d PA(\s-v t J,J-t ,r�k fanning &Zonin> Tree A ministrator Project: (\L&-) 1.-- a av'.i v.( Quack •Public Works e.Dn ..1 Public Utilities Public Safer Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ['Denied. Not applicable L (Circle one.) Comments: BUILDIN PLANNING & ZONING //- 2 Q/ Reviewed by: / Date: 11 a TREE ADMIN. Second Review: ❑Approved as revised. ['Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. fNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 Syv.kfe., City of Atlantic Beach APPLICATION NUMBER ir)'iiiSA Building Department (To be assigned by the Building Department.) 800 Seminole Road Pk (�_O �j -0 Atlantic Beach, Florida 32233-5445 J l Phone (904)247-5826 • Fax(904)247-5845 ����� f l� J1119%- E-mail: building-dept@coab.us Date routed: l City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: IS CO S ctr\idlm ctch Lin. De•artment review required Yes No :uildin• ') Applicant: Q 0 l Ka1p0I 4- Ce.,As1abio-t b,,,iianning &Zoning Tree A•ministra or Project: 11 (2,t.,,,) S“Yn�.Q, �a - (y,i 1 at-VON-6� QE—Publicv`i°rksTh�On� J ic Utilities Public Sa fy Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: .proved. ❑Denied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by:/9 Date: (&‘.--3&—I 7 J TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 S Lnrjr, City of Atlantic Beach �s S, Building Department APPLICATION NUMBER C (To be assigned by the Building Department.) 800 Seminole Road ��c ' ^0�� , Atlantic Beach, Florida 32233-5445 o['r J 4 v Phone (904)247-5826 • Fax(904)247-b82152 s 2017 �� II I 0;00— E-mail: building-dept@coab.us Date routed: l cS L t� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: IS tiO S ark Qlkk &P-Ctc r Lvi. De artment review required Yes No uildin Applicant: 0` aypp( k C rs{.(Ltc 'cr J-t&-ik ZonirigTh Tree Administra r Project: 11 S‘(`l�i�-Q--41v14 ll( ai1/4-ClO( ka Public Works rtOn\-1 Public Utilities` Public Safe y Fire Services Review fee $ _ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: (pproved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING / PLANNING & ZONING Reviewed byJ Date:A -/7 TREE ADMIN. Second Review: ['Approved as revised. ❑Denied. I INot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 C vifiJ, City of Atlantic Beach APPLICATION NUMBER �� Building Department (To be assigned by the Building Department.) _ 800 Seminole Road _O ��,- Atlantic Beach, Florida 32233-5445 L. cT Phone(904)247-5826 • Fax(904)247-5845 1013-s (� �� In- City J;t1�' Email: building dept@coab.us �Cr Date routed: web-site: http://www.coab.us 2 6 20�� APPLICATION REVIEW AND TRACKING FORM Property Address: IS CO S A(tk -ctorl un• Department review required Yes No uilding ) _ Applicant: o a-ypor PA Asksa.kc,;0,0h&,,,i fanning &Zoning Tree Administrator Project: IN 5“4-Q.-4.(ytit k.v.( aik-Cta`Qaublic Works Public Utilities Public Safet' Fire Services Review fee $ F V Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING �J PLANNING &ZONING Reviewed by: 2 v/ ` — Date: /( TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PU r,ORKSJ Comments: ' •UBLIC UTILITIE 'I— 2-17 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. INot applicable Comments: Reviewed by: Date: Revised 05/19/2017 BUILDING PERMIT APPLICATION OFFICE C O P Y CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: # 156 Sandy Beach Lane, COAB, 32233 Permit Number: S�� Legal Description: 38-2S29E-7.41B De Castro Y Ferrr Grant PT RECD O/R 16531-2248 Parcel# Blk: 1 Lot: 7 Floor Area of Sq.Ft. Sq.Ft Valuation of Work$110,000 Proposed Work heated/cooled 1170 non-heated7cooled 200 Class of Work(circle one): New (X) Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No(X) N/A Florida Product Approval # For multiple products use product approval form Describe in detail the type of work to be performed: Construct attached two story Quad single family homes Property Owner Information: Name: Beaches Habitat for Humanity Address: 797 Mayport Rd City Atlantic Beach State FL Zip 32233 Phone#904-241-1202 E-Mail or Fax#(Optional)#904-241-4310,rpeterson@beacheshabitat.org Contractor Information: Company Name:201 Mayport Construction Management, LLC Qualifying Agent: Robert Peterson Address: 2768 State Rd.AlA#701 City Atlantic Beach State FL Zip 32233 Office Phone 904-595-5798 Job Site/Contact Number 904-334-1202 Fax# State Certification/Registration#CGC1506666 Architect Name &Phone# Ju`;a' Over Q U�' J D`1 " glo 2 8 Engineer's Name& Phone# (Th C.h ore I G ! l cls r Gt 01/4- — F o— 4927 rf Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six 6)months at any time after work is commenced. I understand that separate permits must be secured for ElectricallYork, Plumbing,Signs, Wells, Pools, Furnaces, Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I herebycertify that I have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this type ofworkwill be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any othe deral,state,or local law regulating construction or the performance of construction. Signature of Owngc /5")w' Signature of Contractor Print Name Print Name Sworn to and subscribed b, efofe me Sworn to and subscribed before me this / i— Day of y��--�•cr , 2011 this /9"Day of 2 - ,20 I7_ Nntury Public l otary Pu' is - , 201 Mr. Kayle Moore Public Utilities Director City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 Mr. Moore I have submitted a building permit application for the Quad`B"" located at: #156,160,164,168 Sandy Beach Lane, COAB (Blk. # 1, Lots #4,5,6,7) Beaches Habitat will not be installing a fire sprinkler in this structure. In addition, according to our HOA agreement we will be installing an irrigation system for the common areas. Please give me a call (904-241-1222, or 334-1202) if you require any additional information. Sincerely, 41 4 R•.- - '- -• , ----- - Construction Director City of Atlantic Beach PUBLIC UTILITIES DEPARTMENT `' 1200 Sandpiper Lane f Atlantic Beach, FL 32233 A-/----:-r - - ' ( 1904 247-5834 i NEW WATER / SEWER TAP REQUEST Date // - Z – 1 7 Project Address (5 Co 5i4,v 0 y 2 E C/4 6,4au C Number of Units ( Commercial Residential Multi-Family 3 New Water Tap(s) & Meter(s) Meter Size(s) q New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application# S (7 — 0 Z 333 mu L w( r iir_,6 .(/ , /lA Water System Development Charge $ (aPc//ki C--- Sewer System Development Charge $ //t; SQ C ( r &€Q0 - Water Meter Only $ / 8 577_,Y3 Reclaim Meter Only $ Water Meter Tap $ Sewer Tap $ Cross Connection $ 5b . UCS Other $ TOTAL $ 2 5 5, (DC) (Notes) APPROVED Kayle Moore, P.E. 7 Date ///3/1 7 Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED Permit Attachment of for Permit# issued 20 Atlantic Beach,FL 32233 Owner's Name: �atsi �es « � Pro e R.E. #: p rtY Address: Subdivision: } � Lot#/Block#: �1 # 1 I (�luctc 33- I REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT,issued on this by Atlantic Beach, Florida, a municipal corporation organized and existing under the laws of the State2e , of Florida, hereinafter referred to as "CITY" and ,�,« oa, hereinafter referred to as "USER". of Atlantic Beach; Florida, WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right enter upon the property of the City of Atlantic Beach for the tos Beach Right-of-Way/Easement permit numbers noted above(copiespattached)escribed in the City of Atlantic This work is generally described as: It ► *�uew4 i, R. o. w. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30)days notice by CITY to the USER, said notice to USER shall given by certified •mail, return receipt r be -I 1 Yy� v k = P requested, to the following address: • a • The depositing of said notice of cancellation in the United States mail shall constitute the cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. notice of The USER shall promptly make any and all necessary repairs to any facility erected or maintained in exercise of the privilege herein granted and shall at all times maintain said facili the ty in good and safe condition. In the event it is necessary for the CITY or the City's a roe approved representative or other franchised utility to enter upon the above-described P p rty of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacin , or adding to of the utilities and facilities of the CITY or franchise utility provider. g The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code, and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 The USER, prior to making any changes from approval from the City oalAtlantican Beach,hnPublic Wohj Department,the approved plans and/or method, discretionpof the Cp rtment,for said change. must USERoshall,tain at the CITY, be requested to submit as-built drawings showing after the day of completion. The at the This permit shall insureg vying the change within thin}, (30) days to the benefit of, and be binding upon, the USER and their respective assigns, p ve successors and USER shall meet the terms and conditions of this permit and to specifications, to all of the applicable include utilities locate requirements State and CITY laws nights-of--way and other public land. USER and use • be saved haat'and byfurther agrees that the CITY sofficers limitations/requirementss and a plof the USER from and its officers public liabilities are hereby assumed byany of the work herein under the t and employees shall the USER. terms of this permit and that all of said D'TED and SIGNED thi qe„'-day of_afte. 201' BY: / / ol�rar'N'�ea,, KYLE MURRAY P 0r :+ , Notary Public-State of Florida OWneif `'' - Commission # FF 941841 (to be signed "' - in sence of the Notary) '',��F�,A;' My Comm.Expires Apr 2,2020 Bonded through National Notary Assn STATE OF F FLORIDA COUNT��y OF DIN 74______On thi )fie(-- day of and for said County and personally appeared before me, a No State, pP the property �Y Public in and who executed the fore oin 'Atlantic Beach,Florida,known to me to be the person(s) ower of and voluntarily and for the uses and meant' who acknowledged to me that he or she executed the described in s Purposes therein mentioned. rine freely Notary Public in for said County and State CITY OF ATLANTIC BEACH, FLORIDA a municipal corporation: ' Approved: / '__ • • -- - r 'ub c (forks director For4/0,1q%i 1.1 ermits where city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2 7 t' CITY OF ATLANTIC 9 n C BEACH o f CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF 800 Seminole Road • WAY AND ,, Atlantic Beach,Florida 32233-5445 EASEMENTS PLEASE SUBMIt;®MPLETE SETS OF PLANS904-247-5800 WITH APPLICATION. Fax 904-247-5845 Date Job Address 1 Su SanC ) co, La"� _ LUA $ PERMIT# lot ��. p'✓h C"rStfirs. ISSUED BY THE CITY Permifee: ' _ V'1'"r�tw�e,,f Permittee Address: Z p Telephone �ct ay —3 / Z—� Requesting Permission to Construct: e r( +., t • LZ33 ria ✓.. ;t„,.. d „..iv Location: (Reference to Cross-Street) Q (Z. 1. Applicant declares that prior to filing this application S ,,,t_' t, , i �� on he has ascertained the location of all existing utilities both aerial and underground and the accurate locations are shown o A Letter of Notification was n the sketches. mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Bell South Telephone Company Ferrell Gas Yes( ) No ( ) Date: Comcast Yes ( ) No ( ) Dafe: Yes ( ) No ( ) Date: 2. Whenever necessaryYes ( ) No ( ) Date: the construction, repair, improvement, alteration or relocation for all, or anymaintenance, safe and efficient operation, Works, any or all of of poles, Wo e on of said street or easement as determined by hereunder, shall be immediatelyd ices, from said streetsr orauthorized P razed, pipes, cables or other facilities the Director of Public required bthe Director of Public and appreset urtenances relocatedenauteonzas authorized. Works, and at the expense of the ePe Permittee unless rembu semen as 3- All work shall meet City of Atlantic Beach or Florida De performed the supervision nt e pSert rmtendent) located at of e..t<- Department of Transportation Standards and be 4. All materials ld and equipment ashall be su;ect to n s� ...-4- �- ,,. I (Contractor's Project 5. Al! city i — Telephone#: ty property shall be to its original condition as far as inlog- y- 11-42-1_ inspection by the Director of Public Works or his and the manner satisfactory be restored to the oi 6. ty. A of plans covering of this installation, as well practical, keeping designee. P g with city specifications Pat sketchof this permit covering detailsens sof thin, as, a copy ofr a recentnsurvey lot ibe n an increase in im.ervious area on owner's or in the taht of{yeti,are to be included with this a 7. Thispermitteelication. made a shall commence actual construction in cit more than 60 days from date of permit approval, to make sured no changes have occurred in ethe fade with days. then permittee must reviewy If the beginning 6. It is Public Worksrand that the andarea affect permit with the Directordate of City's right, title and interest agreed in the land rightsto bea entered privilegesupon hereinnd usedtout are granted the permitted construction.tenof yassume all risk of and indemnify,l dterd oandset are olden, and only to the extent of the timagaes, any and all isks, damage, defend, and save harmlessythe eC City of Atlantic Beachr fromaa all exercises by the holder of the aforesaid rights and privileges. and cost of expenses arising in any manner of the exercise or attempted 9. The Director of Public Works shall be and immed:tely upon completion. notified twenty-four (24) p d hours prior to starting work and again OWNER 1 Signed: ,"t ,,,�����„ Before'-"5-this ,i`�`_ ,o,,,0 •c0 KYLE MURRAY Date: . ' its Notary Public-St rp of Florida State Of Florida, has personal) appeared day of --1 1 7 '', z y in the County of Duval, ,� 4 Commission e rF Notary Public at Large,State of Florida, County of Duval. 941841 My commission expires: 's My Come Apr 2,2020 t %°�����`°° Bonded tr.' Notary Assn. Produced Identification Persona y now n: r `G� OFFICE COPY DO NOT WRITE BELOW- OFFICE USE ONLY Applica. e Co.es: 2010 FLORIDA BUILDING CODE Review Result circle one : • Approved Disapproved Approved'w/ Conditions Review Initials/Date: ni //- 7-17 Development Size Habitable Space /170 s. Non-Habitable 20 s.ri npervious area • 4iscellaneous Information ►ccupancy Group g-3 ype of Construction "& imber of Stories 2 ning District R - Cr .x. Occupancy Load Sprinklers Required • )d.Zone ditions/Coin .encs: PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: OceanGate: Quad"B" Permit# Es / 7 - o 33 OFFICE COPY Project Address: #156,160,164,168 Sandy Beach Lane, COAB, 32233 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.o% Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Steel Door FL4904 2. Sliding 3. Sectional 4. Roll up Clopay Garage Door-HDG FL5684.10 5. Automatic 6. Other B. WINDOWS 1. Single hung Atrium Single Hung Window FL11834.10 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11.. Dual action 12.. Other PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA C. PANEL WALL 1. Siding James Hardie Cemplank siding FL13192.1 2. Soffits Crane Vinyl Soffit FL2495-R1 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco Acrocrete Synthetic finish coat 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles GAF 30 yr architectural FL10124 2. Underlayments RhinoRoof Syn. Underlayment FL15216 3. Roofing fasteners 4. Nonstructural metal roof Millenia Metals Form rolled metal FL5211.2 R4 5. Built-up roofing 6. Modified bitumen Certainteed Flintlastic SA FL2533 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 1 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coasts 15. Roof tile adhesive - 16. Spray applied polyurethane roof 17. Other E. SHUTTERS 1. Accordion Shutter Shield Accordion FL9569.1 2. Bahama 3. Storm panels Madden Mfg. Storm Panels FL5329.1 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor Simpson Strong- H16S FL1423.6 Tie MTS 12 FL474.253 2. Truss plates MiTek Industries Truss Plates FL2197 3. Engineered lumber Tus-Joist- Engineered Lumber FL1630 Weyerhauser 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall • -+� PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturer,product description and State approval number for the products used on this project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above, on the job site available to the inspector. The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be inspected, they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to include each new product in the categories listed above and will be highlighted to indicate the new products and required information. Authorized Project Agent: Robert Peterson; Director of Construction (Contractor or Design Professional) (Print Name) ignature) - Company Name: Beaches Habitat for Humanity Mailing Address: 797 Mayport Road , -+'a► PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA City: Atlantic Beach State: FL Zip Code: 32233 Telephone Number: ( 904) 241-1222 Fax Number: (904 ) 241-4310 Cell Phone Number: (904) 334-1202 E-mail Address: rpetersonna,beacheshabitat.org 66(., FORM R405-2014 OFFICE COPY RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include 0 This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGaugee-USRCZB v5.1 9/15/2017 4:20:00 PM Page 1 of 1 . OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-QUADPLEX-OUTSIDE-156SB Builder Name: BEACHES HABITAT Street: 156 SANDY BEACH LANE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville County:: DUVAL(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1637.3 sqft.) Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 ft2 b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (605.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area above grade(ft2) 1170 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11.Ducts R ft2 7. Windows(130.0 sqft.) Description Area a.Sup: 1st Floor,Ret:1st Floor,AH:Attic 6 165 a. U-Factor: Dbl,U=0.30 130.00 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (605.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 29.40 Glass/Floor Area: 0.111 PASS Total Baseline Loads: 33.09 I hereby certify that the plans and specifications covered by Review of the plans and TkiB ST �0, TS'% this calculation are in compliance with the Florida Energy specifications covered by this � ...............;. -.. p •; Code. calculation indicates compliance `� .,,,,,�tr = '� AMY WILKERSON with the Florida Energy Code. c F•rq,,,,�lr•.... ; :;,'`;.�'",{p PREPARED BY: Before construction is completed ` '_ •`'' 4. �'j DATE: 09/15/2017 this building will be inspected for �,11 -. _y compliance with Section 553.908 i 4 I hereby certify tha is building, as designed, is in compliance Florida Statutes. '4P .. - :.•C with the Florida Energ e. COD wE ., ,: OWNER/AGENT: BUILDING OFFICIAL: /� DATE: DATE: �✓ ll- I-/7 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017 this project requires an envelope leakage test report with envelope leakage no greater than 3.0 ACH50(R402.4.1.2). - Compliance requires a roof emittance test in accordance with R405.7.2 9/15/2017 4:20 PM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: HABITAT-QUADPLEX-OUTSI Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1170 Lot# Owner: Total Stones: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 0 Street: 156 SANDY BEACH LA Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 1170 9360 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 565 4520 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 605 4840 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge lnsulatio 1st Floor 190 ft 0 605 ft2 _ _ 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 638 ft2 100 ft2 Medium 0.75 No 0.9 Yes 0 18.4 V ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 605 ft2 N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 Batt 605 ft2 0 Wood 9/15/2017 4:20 PM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below S Space Qmt Tp Wall Type p R-Valu Ft In Ft In Area R-Value Fraction Ahenr (;rade% 1 N Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 2 E Exterior Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 3 S Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 4 W Neighbor Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 5 N Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 6 E Exterior Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 7 S Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 8 W Neighbor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-ValueWidth Height Area Ft In Ft In 1 N Insulated 1st Floor Metal .46 3 6 8 20 ft2 2 S Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 N 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 E 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 E 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 N 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 6 N 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 7 E 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 E 6 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 S 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 S 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000152 468 25.69 48.32 .1446 3 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 24 kBtu/hr 1 sys#1 9/15/2017 4:20 PM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 3 of 4 L FORM R405-2014 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 24 kBtu/hr 720 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— ---Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programableri Thermostat:Y Ceiling Fans: HeatingCoolin Jan Eeb Mar May Aug ec Jan f X�Feb X�Mar €XX i AAppr I May �Xi Jun Jun V Jul I:1 Aug �Xi Sep Sep X�Oct Oct �X�Nov XNov �Dec Venting Jan [[X Feb X Mar Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 9/15/2017 4:20 PM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 . ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index,the more efficient the home. 156 SANDY BEACH LANE, ATLANTIC BEACH , FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 fl2 b.Frame-Wood,Common R=19.0 498.67 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area(ft2) 1170 b.N/A R= ft2 7. Windows** Description Area c.N/A R= ft2 a. U-Factor: DbI,U=0.30 130.00 ft2 11.Ducts R ft2 a.Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 24.0 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 24.0 HSPF:8.50 Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 a.Electric EF:0.92 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ••.THE sT Construction through the above energy saving features which will be installed (or exceeded) yob` t aT'..... in this home before final inspection. Otherwise, a new EPL Display Card will be completed '. y �- ';s+ based on installed Code compliant features. .um, fr!--.; ;,,t,,�o Builder Signature: _� _ Date: c- b---c>V/ j 0.. 'A., KAY. Address of New Home: /�(_ g,��c/j City/FL Zip: r (� ��j^ " ' '�. _` �c .............IS?� 7 2__2_1,> °D wr *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/15/2017 4:20 PM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 156 SANDY BEACH LANE Permit Number: ATLANTIC BEACH , FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. l7 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. O R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. ▪ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and retum registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. O R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. O R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. o R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 9/15/2017 4:20 PM EnergyGauge8 USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. O R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. O R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. O R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be tumed off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. O R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. p R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 9/15/2017 4:20 PM EnergyGauge®USA-v5.1- -Section R405.4.1 Compliant Software Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer. in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2, Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 9/15/2017 4:20 PM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3 • FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-QUADPLEX-OUTSIDE-156SB Builder Name: BEACHES HABITAT Street: 156 SANDY BEACH LANE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 9/15/2017 4:20 PM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: HABITAT-QUADPLEX-OUTSIDE-156SB Builder Name: BEACHES HABITAT Street: 156 SANDY BEACH LANE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 1170 sq.ft. Cond.Volume: 9360 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: CFM(50): C: n: R: ELA: Single or Multi Point Test Data HOUSE PRESSURE FLOW: EqLA: 1 Pa cfm ACH: 2 Pa cfm SLA: 3 Pa cfm ACH(50) * : 4 Pa cfm * For prescriptive projects, tested leakage must be 5 Pa cfm <=7 ACH(50). For performance projects, tested 6 Pa cfm leakage must be <=the ACH(50) shown on Form R405-2014 for this project. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed.beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed, 5. Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing shall be conducted by either I hereby certify that the above envelope leakage individuals as defined in Section ;• O SHE S.. performance results demonstrate compliance , �•; `y;* .. O 553.993(5) or(7), Florida Statutes or with Florida Energy Code requirements in co o individuals licensed as set forth in ` • "'� accordance with Section R402.4.1.2. " _- o Section 489.105(3)(f), (g), or (i) or an ;'`'.; : ' approved thirdparty. A written report � :. � ` of the results of the test shall be signed %: .''.. SIGNATURE: by the third party conducting the test and provided to the code official. COpyy ..{4J.:'� PRINTED NAME: DATE: BUILDING OFFICIAL: /1/9f DATE: f—"7l 9/15/2017 4:21 PM EnergyGaugeO USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 Residential System Sizing Calculation Summary Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 9/15/2017 Location for weather data: Jacksonville, FL -Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidity data: Interior RH (50%) Outdoor wet bulb(77F) Humidity difference(49gr.) Winter design temperature(TMY3 99%) 29 F Summer design temperature(TMY3 99%) 95 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 41 F Summer temperature difference 20 F Total heating load calculation 17030 Btuh Total cooling load calculation 9403 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity %of calc Btuh Total(Electric Heat Pump) 140.9 24000 Sensible(SHR=0.75) 233.7 18000 Heat Pump +Auxiliary(0.0kW) 140.9 24000 Latent 352.8 6000 Total (Electric Heat Pump) 255.2 24000 WINTER CALCULATIONS Winter Heating Load(for 1170 sqft) Load component Load Walls(18.0%) Window total 130 sqft 1599 Btuh Wall total 969 sqft 3069 Btuh Ceilings(413f6) Door total 40 sqft 754 Btuh Ceiling total 605 sqft 790 Btuh I Windows(9.4%)l Floor total 605 sqft 9192 Btuh Infiltration 36 cfm 1626 Btuh Duct loss 0 Btuh Subtotal 17030 Btuh Infil.(9.5%) Ventilation 0 cfm 0 Btuh Floors(54.0%) TOTAL HEAT LOSS 17030 Btuh (Doors(4.4%) SUMMER CALCULATIONS Summer Cooling Load(for 1170 sqft) Load component Load Window total 130 sqft 2034 Btuh Wall total 969 sqft 1677 Btuh Ceilings(92%) Door total 40 sqft 409 Btuh Ceiling total 605 sqft 867 Btuh Vlalls(17.8%) Windows(21.6%) Floor total 0 Btuh Infiltration 27 cfm 595 Btuh Internal gain 2120 Btuh Duct gain 0 Btuh Sens.Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Doors(4.4%) Total sensible gain 7702 Btuh Latentint(8.5%) Latent gain(ducts) 0 Btuh Latent gain(infiltration) 901 Btuh Infil.(15.9%) Latent gain(ventilation) 0 Btuh Latent gain(intemal/occupants/other) 800 Btuh Int.Gain(22.5%) Total latent gain 1701 Btuh TOTAL HEAT GAIN 9403 Btuh ,iar„ik EnergyGauge®System Sizing 8th Edition PREPARED BY: DATE: MAISJIC 3 ,Numr- EnergyGauge®/USRCZB v5.1 Residential Window Diversity MidSummer Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156S6 ATLANTIC BEACH , FL 32233 9/15/2017 Weather data for: Jacksonville -Defaults Summer design temperature 95 F Average window load for July 2050 Btuh Cooling setpoint 75 F Peak window load for July 2881 Btuh Summer temperature difference 20 F Excusion limit(130%of Ave.) 2665 Btuh Latitude 30.5 North Window excursion (July) 216 Btuh WINDOW Average and Peak Loads a._._._. ._._._._._.�._a_a_a_aa.a._._._._._aamaa., Q2.' .::.. _ "74k --&- 1,500, 1,00D .�4 12 14 16 18 20 —•— Window Load(Btuh) ama. Limitfor excursion 12 Hour Average Total July Window Load(Radiation and conduction) Warning:This application has glass areas that produce relatively large heat gains for part of the day. Variable air volume devices may be required to overcome spikes in solar gain for one or more rooms.A zoned system may be required or some rooms may require zone control. n,+ns r, EnergyGaugee System Sizing for Florida residences only PREPARED BY: - DATE: FtRIM1fH 1 EnergyGauge®/USRCZB v5.1 Residential Window Diversity October Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 9/15/2017 Weather data for: Jacksonville -Defaults Summer design temperature 95 F Average window load for October 2285 Btuh Cooling setpoint 75 F Peak window load for October 2969 Btuh Summer temperature difference 20 F Excusion limit(130%of Ave.) 2971 Btuh Latitude 30.5 North Window excursion (October) None WINDOW Average and Peak Loads 2,05D •1 1,5 • 1,0n 8 1 12 14 16 18 20 -• iNindow Load (Bluh) -•-• Lirnitforexcursion 12 Hour Average Total October Window Load(Radiation and conduction) The October window load for this house does not exceed the window load excursion limit. This house has adequate October window diversity. hewed k EnergyGauge®System Sizing for Florida residences only PREPARED BY: _10.x,.....-, DATE: t1RW1101__1 EnergyGauge®I USRCZB v5.1 System Sizing Calculations - Winter Residential Load - Whole House Component Details Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 Building Type: User 9/15/2017 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference:41.0 F (TMY3 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 1 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh 2 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh 3 2, NFRC 0.30 Vinyl 0.30 E 10.3 12.3 127 Btuh 4 2, NFRC 0.30 Vinyl 0.30 E 6.0 12.3 74 Btuh 5 2, NFRC 0.30 Vinyl 0.30 N 15.5 12.3 191 Btuh 6 2, NFRC 0.30 Vinyl 0.30 N 15.5 12.3 191 Btuh 7 2, NFRC 0.30 Vinyl 0.30 E 10.3 12.3 127 Btuh 8 2, NFRC 0.30 Vinyl 0.30 E 13.8 12.3 169 Btuh 9 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh 10 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh Window Total 130.0(sqft) 1599 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame-Wood -Ext (0.077) 19.0/0.0 112 3.17 356 Btuh 2 Frame-Wood -Ext (0.077) 19.0/0.0 233 3.17 738 Btuh 3 Frame-Wood -Ext (0.077) 19.0/0.0 140 3.17 444 Btuh 5 Frame-Wood -Ext (0.077) 19.0/0.0 129 3.17 409 Btuh 6 Frame-Wood -Ext (0.077) 19.0/0.0 225 3.17 714 Btuh 7 Frame-Wood -Ext (0.077) 19.0/0.0 129 3.17 409 Btuh Wall Total 969(sqft) 3069 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated-Exterior, m (0.460) 20 18.9 377 Btuh 2 Insulated-Exterior, m (0.460) 20 18.9 377 Btuh Door Total 40(sqft) 754Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/L/Shing (0.032) 30.0/0.0 605 1.3 790 Btuh Ceiling Total 605(sqft) 790Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 190.0 ft(perim.) 48.4 9192 Btuh Floor Total 605 sqft 9192 Btuh Envelope Subtotal: 15405 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.23 9360 1.00 36.1 1626 Btuh Duct load Average sealed, R6.0, Supply(Con), Return(Con) (DLM of 0.000) 0 Btuh All Zones Sensible Subtotal All Zones 17030 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 Building Type: User 9/15/2017 FiNHOLE HOUSE TOTALS Subtotal Sensible Heat Loss 17030 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 17030 Btuh EQUIPMENT 1. Electric Heat Pump # 24000 Btuh Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) A"w or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) ..o....6.4, "^' MANtIRL Version 8 EnergyGauge®/USRCZB v5.1 Page 2 System Sizing Calculations - Summer Residential Load - Whole House Component Details Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 9/15/2017 Reference City: Jacksonville, FL Temperature Difference: 20.0F(TMY3 99%) Humidity difference:49gr. Component Loads for Whole House Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 13.8 0.0 13.8 9 9 123 Btuh 2 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 13.8 0.0 13.8 9 9 123 Btuh 3 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 10.3 0.0 10.3 9 25 257 Btuh 4 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 6.0 0.0 6.0 9 25 149 Btuh 5 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 15.5 0.0 15.5 9 9 139 Btuh 6 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 15.5 0.0 15.5 9 9 139 Btuh 7 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 10.3 0.0 10.3 9 25 257 Btuh 8 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.Oft 13.8 0.0 13.8 9 25 342 Btuh 9 2 NFRC 0.30,0.30 B-L No S 1.0ft 1.0ft 15.5 12.6 2.9 9 11 145 Btuh 10 2 NFRC 0.30,0.30 B-L No S 1.0ft 1.0ft 15.5 12.6 2.9 9 11 145 Btuh Excursion 216 Btuh Window Total 130(sqft) 2034 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Wood-Ext 0.08 19.0/0.0 112.4 1.7 195 Btuh 2 Frame-Wood-Ext 0.08 19.0/0.0 233.0 1.7 403 Btuh 3 Frame-Wood-Ext 0.08 19.0/0.0 140.0 1.7 242 Btuh 5 Frame-Wood-Ext 0.08 19.0/0.0 129.0 1.7 223 Btuh 6 Frame-Wood-Ext 0.08 19.0/0.0 225.2 1.7 390 Btuh 7 Frame-Wood-Ext 0.08 19.0/0.0 129.0 1.7 223 Btuh Wall Total 969(sqft) 1677 Btuh Doors Type Area (sqft) HTM Load 1 Insulated-Exterior 20.0 10.2 205 Btuh 2 Insulated-Exterior 20.0 10.2 205 Btuh Door Total 40 (sqft) 409 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Shingle 0.032 30.0/0.0 605.0 1.43 867 Btuh Ceiling Total 605(sqft) 867 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 605(ft-perimeter) 0.0 0 Btuh Floor Total 605.0(sqft) 0 Btuh Envelope Subtotal: 4987 Btuh Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.17 9360 1 27.1 595 Btuh Internal Occupants Btuh/occupant Appliance Load gain 4 X 230 + 1200 2120 Btuh Sensible Envelope Load: 7702 Btuh Duct load Average sealed,Supply(R6.0-Condi),Retum(R6.0-Condi) (DGM of 0.000) 0 Btuh Sensible Load All Zones 7702 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 9/15/2017 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 7702 Btuh Sensible Duct Load 0 Btuh Total Sensible Zone Loads 7702 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 7702 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 901 Btuh Latent ventilation gain 0 Btuh Latent duct gain 0 Btuh Latent occupant gain (4.0 people @ 200 Btuh per person) 800 Btuh Latent other gain 0 Btuh Latent total gain 1701 Btuh TOTAL GAIN 9403 Btuh EQUIPMENT 1. Central Unit # 24000 Btuh *Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No),Blinds(B),Draperies(D)or Roller Shades(R)) n.rydk - For Blinds:Assume medium color, half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed (IS-Insect screen: none(N), Full(F)or Half(Y2)) *""m"""""a'eih (Ornt-compass orientation) Version 8 EnergyGauge®/USRCZB v5.1 Page 2 System Sizing Calculations - Winter Residential Load - Room by Room Component Details Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 Building Type: User 9/15/2017 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 41.0 F (TMY3 99%) Component Loads for Room#1: 1st Floor Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 1 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh 2 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh 3 2, NFRC 0.30 Vinyl 0.30 E 10.3 12.3 127 Btuh 4 2, NFRC 0.30 Vinyl 0.30 E 6.0 12.3 74 Btuh Window Total 43.9(sqft) 540 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame-Wood - Ext (0.077) 19.0/0.0 112 3.17 356 Btuh 2 Frame-Wood - Ext (0.077) 19.0/0.0 233 3.17 738 Btuh 3 Frame-Wood -Ext (0.077) 19.0/0.0 140 3.17 444 Btuh Wall Total 485(sqft) 1538 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated-Exterior, m (0.460) 20 18.9 377 Btuh 2 Insulated - Exterior, m (0.460) 20 18.9 377 Btuh Door Total 40(sqft) 754Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/L/Shing (0.032) 30.0/0.0 605 1.3 790 Btuh Ceiling Total 605(sqft) 790Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 190.0 ft(perim.) 48.4 9192 Btuh Floor Total 605 sqft 9192 Btuh Room Envelope Subtotal: 12814 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.23 4520 0.50 18.1 815 Btuh Duct load Average sealed,Supply(R6.0-Cond.),Return(R6.0-Cond.) (DLM of 0.000) 0 Btuh Room#1 Sensible Room Subtotal 13629 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 Building Type: User 9/15/2017 Component Loads for Room#2: 2nd Floor Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 5 2, NFRC 0.30 Vinyl 0.30 N 15.5 12.3 191 Btuh 6 2, NFRC 0.30 Vinyl 0.30 N 15.5 12.3 191 Btuh 7 2, NFRC 0.30 Vinyl 0.30 E 10.3 12.3 127 Btuh 8 2, NFRC 0.30 Vinyl 0.30 E 13.8 12.3 169 Btuh 9 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh 10 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh Window Total 86.1(sqft) 1059 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 5 Frame-Wood -Ext (0.077) 19.0/0.0 129 3.17 409 Btuh 6 Frame-Wood -Ext (0.077) 19.0/0.0 225 3.17 714 Btuh 7 Frame-Wood -Ext (0.077) 19.0/0.0 129 3.17 409 Btuh Wall Total 483(sqft) 1531 Btuh Room Envelope Subtotal: 2590 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.23 4840 0.50 18.0 811 Btuh Duct load Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DLM of 0.000) 0 Btuh Room#2 Sensible Room Subtotal 3401 Btuh WHOLE HOUSE TOTALS Subtotal Sensible Heat Loss 17030 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 17030 Btuh EQUIPMENT 1. Electric Heat Pump # 24000 Btuh EnergyGauge®/USRCZB v5.1 Page 2 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 Building Type: User 9/15/2017 67 Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(Manual]Heat Transfer Multiplier) mow Version 8 EnergyGauge®/USRCZB v5.1 Page 3 System Sizing Calculations - Summer Residential Load - Room by Room Component Details Project Title: 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 9/15/2017 Reference City: Jacksonville, FL Temperature Difference: 20.0F(TMY3 99%) Humidity difference:49gr. Component Loads for Room#1: 1st Floor Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.Oft 13.8 0.0 13.8 9 9 123 Btuh 2 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 13.8 0.0 13.8 9 9 123 Btuh 3 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 10.3 0.0 10.3 9 25 257 Btuh 4 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 6.0 0.0 6.0 9 25 149 Btuh Window Total 44 (sqft) 652 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Wood-Ext 0.08 19.0/0.0 112.4 1.7 195 Btuh 2 Frame-Wood-Ext 0.08 19.0/0.0 233.0 1.7 403 Btuh 3 Frame-Wood-Ext 0.08 19.0/0.0 140.0 1.7 242 Btuh Wall Total 485(sqft) 840 Btuh Doors Type Area(sqft) HTM Load 1 Insulated-Exterior 20.0 10.2 205 Btuh 2 Insulated-Exterior 20.0 10.2 205 Btuh Door Total 40 (sqft) 409 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Shingle 0.032 30.0/0.0 605.0 1.43 867 Btuh Ceiling Total 605 (sqft) 867 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 605(ft-perimeter) 0.0 0 Btuh Floor Total 605.0 (sqft) 0 Btuh Zone Envelope Subtotal: 2769 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.17 4520 0.50 13.6 298 Btuh Internal Occupants Btuh/occupant Appliance Load gain 0 X 230 + 1200 1200 Btuh Sensible Envelope Load: 4267 Btuh Duct load Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DGM of 0.000) 0 Btuh Sensible Zone Load 4267 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_JACKSONVILLE_INTL ARPT 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 9/15/2017 Component Loads for Room#2: 2nd Floor Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 5 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 15.5 0.0 15.5 9 9 139 Btuh 6 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 15.5 0.0 15.5 9 9 139 Btuh 7 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 10.3 0.0 10.3 9 25 257 Btuh 8 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 13.8 0.0 13.8 9 25 342 Btuh 9 2 NFRC 0.30,0.30 B-L No S 1.0ft 1.0ft 15.5 12.6 2.9 9 11 145 Btuh 10 2 NFRC 0.30,0.30 B-L No S 1.0ft 1.0ft 15.5 12.6 2.9 9 11 145 Btuh Window Total 86(sqft) 1166 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 5 Frame-Wood-Ext 0.08 19.0/0.0 129.0 1.7 223 Btuh 6 Frame-Wood-Ext 0.08 19.0/0.0 225.2 1.7 390 Btuh 7 Frame-Wood-Ext 0.08 19.0/0.0 129.0 1.7 223 Btuh Wall Total 483(sqft) 836 Btuh Zone Envelope Subtotal: 2002 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.17 4840 0.50 13.5 297 Btuh Internal Occupants Btuh/occupant Appliance Load gain 4 X 230 + 0 920 Btuh Sensible Envelope Load: 3219 Btuh Duct load Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DGM of 0.000) 0 Btuh Sensible Zone Load 3219 Btuh The following window Excursion will be assigned to the system loads. Windows July excursion for System 1 216 Btuh Excursion Subtotal: 216 Btuh Duct load 0 Btuh Sensible Excursion Load 216 Btuh EnergyGauge®/USRCZB v5.1 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT 156 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-156SB ATLANTIC BEACH , FL 32233 9/15/2017 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 7702 Btuh Sensible Duct Load 0 Btuh Total Sensible Zone Loads 7702 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 7702 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 901 Btuh Latent ventilation gain 0 Btuh Latent duct gain 0 Btuh Latent occupant gain (4.0 people @ 200 Btuh per person) 800 Btuh Latent other gain 0 Btuh Latent total gain 1701 Btuh TOTAL GAIN 9403 Btuh EQUIPMENT 1. Central Unit # 24000 Btuh 'Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No).Blinds(B),Draperies(D)or Roller Shades(R)) Poseith - For Blinds:Assume medium color,half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed (IS-Insect screen:none(N), Full(F)or Half(%)) ,.,a, (Ornt-compass orientation) .,,w ' Version 8 EnergyGauge®/USRCZB v5.1 Page 3 wrightsoft Manual S Compliance Report Job: 156 SB Lane Date: 10.17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 17489 Btuh Entering coil DB: 76.9°F Outdoor design WB: 77.0°F Latent gain: 3181 Btuh Entering coil WB: 63.6°F Indoor design DB: 75.0°F Total gain: 20670 Btuh Indoor RH: 50% Estimated airflow: 700 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 700 cfm Sensible capacity: 18041 Btuh 103%of load Latent capacity: 4022 Btuh 126%of load Total capacity: 22063 Btuh 107%of load SHR: 82% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 20999 Btuh Entering coil DB: 68.4°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 700 cfm Output capacity: 18689 Btuh 89%of load Capacity balance: 30 °F Supplemental heat required: 2310 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 700 cfm Output capacity: 4.7 kW 77%of load Temp.rise: 50 °F Meets all requirements of ACCA Manual S. wri htsQft' 2017-Oct-17 20:17:23 9 Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 ...\Beaches Habitat\156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE wrightsoft Job: 156 SB Lane 4 Project Summary Date: 10-17-2017 9 Entire House By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Notes: 156 Sandy Beach Lane Desi• n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 Moisture difference 50 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17499 Btuh Structure 14574 Btuh Ducts 3500 Btuh Ducts 2915 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20999 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17489 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2100 Btuh Ducts 1081 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1140 1140 Equipment latent load 3181 Btuh Volume(f3) 9920 9920 Air changes/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 20670 Btuh Equiv.AVF(cfm) 74 38 Req.total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A00300 Cond 25HBC524A00300 AHRI ref 9154698 Coil FX4DNF025L AHRI ref 9154698 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 16800 Btuh Heating output 24000 Btu h @ 47°F Latent cooling 7200 Btuh Temperature rise 31 °F Total cooling 24000 Btuh Actual air flow 700 cfm Actual air flow 700 cfm Air flow factor 0.033 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=30°F Backup: Input=5 kW, Output= 16145 Btuh, 100 AFUE Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f ll htsoft 2017-Oct-1720:17:23 r4►- Wg Right-Suites Universal 2017 17.0.29 RSU09479 Page 1 ..\Beaches Habitat\156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE 4 wrightsoft Right-J® Worksheet Job: 156 SB Lane Entire House Date: 10-17-2017 B : Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Entire House Kitchen 2 Exposed wall 204.0 ft 25.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 14.0 x 11.0 ft 5 Room area 1240.0 f t' 154.0 ft' i I I I r Ty Construction U-value OrHTM Area (ft') I Load I Area (ft') Load number (Btuh/ft'-'F I (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) I I Heat I Cool Gross I N/P/S Heat I Cool 1 Gross N/P/S Heat 1 Cool 1 6 VI 12E-Osw 0.068 ne 2.55 1.43 496 454 1159 652 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 6 0 128 235 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 21 0 445 816 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 15 0 315 578 0 0 0 0 1112E-Osw 0.068 se 2.55 1.43 320 239 609 343 0 0 0 0 11. 1 D c2ow 0.570 se 21.38 38.87 31 4 667 1213 0 0 0 0 10-c2ow 0.570 se 21.38 24.12 15 11 315 355 0 0 0 0 1 D-c2ow 0.570 se 21.38 18.20 15 15 315 268 0 0 0 0 D 1100 0.390 se 14.62 11.78 20 20 298 240 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 496 496 1265 712 88 88 224 126 HD12E-Osw 0.068 nw 2.55 1.43 320 248 632 356 112 92 234 131 1D-c2ow 0.570 nw 21.38 39.24 31 0 667 1224 0 0 0 0 1100 0.390 nw 14.62 11.78 41 41 597 481 20 20 298 240 C 16B-30ad 0.032 - 1.20 1.72 264 264 317 454 64 64 77 110 C 16B-7ad 0.112 - 4.20 6.01 496 496 2083 2983 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 760 125 4622 0 154 25 927 0 1 6 1 c)AED excursion 0 -208 Envelope loss/gain 1 1 1 144341 109101 17601 399 12 a) Infiltration 3065 744 376 91 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 2000 2000 Subtotal(lines 6 to 13) 17499 14574 2136 2491 Less external load 0 0 0 0 Less transfer 0 Redistribution 0 0 0 14 Subtotal 394 141 17499 14574 2530 2632 15 Duct loads 20% 20% 3500 2915 20% 20% 506 526 1 I Air Totalrequirroomed load(cfm) I I I 209991 174891 I l 30361 31561 700 700 101 126 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoft Right-Suite®Universa12017 17.0.29 RSU09479 2017-Oct-1720:17:23 A Beaches Habitat\156 Sandy Beach Lane11140R.up Calc=MJ8 Front Door faces:SE Page 1 4 wrightsoft Right-J® Worksheet Job: 156 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308.Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Utility Bath 1 2 Exposed wall 10.0 ft 9.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 4.0 ft 6.0 x 9.0 ft 5 Room area 24.0 ft' 54.0 ft' - I 1 1 I Ty Construction U-value OrHTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F I (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) I 1 Heat I Cool Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 32 32 82 46 72 66 168 95 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 6 0 128 235 . G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 1112E-Osw 0.068 se 2.55 1,43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.36 38.87 0 0 0 0 0 0 0 0 1 D c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 11 DO 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 0 0 0 0 hD12E-Osw 0.068 nw 2.55 1.43 48 28 70 40 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 20 20 298 240 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 12 12 14 21 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 24 10 371 0 54 9 334 0 6 I c)AED excursion -30 -14 Envelope loss/gain 836 317 630 316 12 a) Infiltration 150 36 135 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 986 353 766 349 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -986 -353 719 237 14 Subtotal 0 0 1485 585 15 Duct loads 20% 20% 0 0 20% 20% 297 117 I 1 Totalrequirroomed load( ) 1 1 1 01 01 1 1 17821 7021 Air cfm0 0 59 28 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .1. �rightsQ . 2017-Oct-17 20:17:23 .. 'P Right-Suite®Universal 2017 17.0.29 RSU09479 Page 2 ...\Beaches Habitat\156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE `f- wrlghtsoft Right-J® Worksheet Job: 156SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Great Mech 2 Exposed wall 55.0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 378.0 ft 6.0 x 5.0 ft 5 Room area 378.0 ft' 30.0 ft' I i I I r Ty Construction U-value Or I HTM Area (ft') LoadArea (ftLoad number (Btuh/ft'-'F (Btuh/f t') or perimeter (ft) (Btuh) I or perimeter (ft) 1I (Btuh) Heat 1 Cool 1 Gross I N/P/S ( Heat I Cool I Gross I N/P/S I Heat I Cool 6 V/ 12E-Osw 0.068 ne 2.55+ 1.43 112 102 259 146 40 40 102 57 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 . -G 1D-c2ow 0.570 ne 21.38 39.24 10 0 222 408 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 D 0 0 1112E-Osw 0.068 se 2.55 1.43 160 110 281 158 0 0 0 0 lir 1 D c2ow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 15 11 315 355 0 0 0 0 1 D c2ow 0.570 se 21.38 18.20 15 15 315 268 0 0 0 0 D 11D0 0.390 se 14.62 11.78 20 20 298 240 0 D 0 0 W 12E-Osw 0.068 sw 2.55 1.43 168 168 428 241 0 0 0 0 hD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11130 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 84 84 101 144 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 378 55 2040 0 30 5 185 0 6 1 c)AED excursion -167 -6 Envelope loss/gain 1 1 42591 17941 2871 52 12 a) Infiltration 826 201 75 18 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 5086 1995 363 70 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 235 45 -363 -70 14 Subtotal 5320 2040 0 0 15 Duct loads 20% 20% 1064 408 20% 20% 0 0 Air Totalrequireroomd load( ) I I I 6385 2448 981 1 I 00 I 01 cfm Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Lt wrights0 Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-1720:17:23 Page 3 ...)Beaches Habitat\156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE 4 wrightsoft Right-J® Worksheet Job: 156 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name M WIC Master 2 Exposed wall 12.0 ft 23.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 5.0 ft 13.0 x 10.0 ft 5 Room area 35.0 ft' 130.0 ft' I I I r r r Ty Construction U-value OrHTM Area (f t') Load Area (f t') Load number (Btuh/ft'-°F I (Btuh/ft') I or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 6 V/ 12E-Osw 0.068 ne 2.55 1.43 40 40 102 57 0 0 0 0 . -r' 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 --G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 111.1 12E-Osw 0.068 se 2.55 1.43 56 56 143 80 104 73 186 104 1D-c2ow 0.570 se 21.38 38.87 0 0 0 0 31 4 667 1213 1 D c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 0 1 D c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 D 1100 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 80 80 204 115 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 35 35 42 60 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 130 130 546 782 F 22A-tpl 0.989 - 37.09 0.00 20 7 254 0 0 0 0 0 6 1 c)AED excursion -19 402 Envelope loss/gain 541 1791 I 1603 2616 12 a) Infiltration 180 44 346 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 721 223 1948 3160 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 184 177 321 309 14 Subtotal 905 400 2269 3469 15 Duct loads 20% 20% 181 80 20% 20% 454 694 1 Totalrequireroom d load(cfm) 1 1 10861 480 l I 27231 41631 Air 36 19 91 167 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. . �1 �rightSQ 2017-Oct-17 20:17:23 ' Ar. + 'r' Right-Suite®U niversal 2017 17.0.29 RSU09479 Page 4 ...\Beaches Habitat\156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE 41- wrightsoft Right-J® Worksheet Job: 156 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name M Linen Bed 3 2 Exposed wall Oft 21 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 3.0 x 5.0 ft 10.0 x 11.0 ft 5 Room area 15.0 ft' 110.0 ft' Ty Construction U-value Or HTM Area (ft') Load I Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool 1 Gross I N/P/S Heat I Cool I Gross N/P/S Heat I Cool 1 6 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 0 0 0 0 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 C 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 11 1D-c2ow 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 1 D c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 1100 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 88 88 224 126 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 80 64 164 92 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 16 0 333 612 1100 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 15 15 18 26 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 110 110 462 662 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 61 c)AED excursion 1 1 ( 181 -21 11841 16781 Envelope loss/gain 2412 a) Infiltration 0 0 316 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 18 24 1500 1985 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 -18 -24 177 168 14 Subtotal 0 0 1677 2153 15 Duct loads 20% 20% 0 0 20% 20% 335 431 Air Total requireroomd load(cfm) I I I OI OI I I 20121 25831 0 0 67 103 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 19111t5pft Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-1720:17:23 w ...)Beaches Habitat1156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE Page 5 - wrightsoft Right-J® Worksheet Job: 156 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Pan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bed 2 Loft 2 Exposed wall 21.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 11.0 ft 1.0 x 146.0 ft 5 Room area 110.0 ft' 146.0 ft' I 1 I I r Ty Construction U-value Or 1 HTM Area (f t') Load I Area (ft') Load number (Btuh/it'-°F (Btuh/ft') 1 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross I N/P/S Heat Cool I Gross I N/P/S Heat I Cool 6 V✓ 12E-Osw 0.068 ne 2.55 1.43 88 73 187 105 112 102 259 146 . -C 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 10 0 222 408 -G 1D-c2ow 0.570 ne 21.38 39.24 15 0 315 578 0 0 0 0 1112E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1 D clow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 1100 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 80 64 164 92 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 16 0 333 612 0 0 0 0 1100 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 110 110 462 662 146 146 613 878 F 22A-tpl 0.989 - 37.09 0.00 44 8 312 0 56 5 199 0 6 I c)AED excursion -69 I I -56 Envelope loss/gain I} 1773 1980 I 1294 1376 12 a) Infiltration 316 77 210 51 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2089 2287 1504 1427 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 442 420 -1504 -1427 14 Subtotal 2531 2707 0 0 15 Duct loads 20% 20% 506 541 20% 20% 0 0 Total room load 3037 3248 0 Air required(cfm) I I l 101 1301 I I 001 0I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. •1 w�`ghtscaft 2017-Oct-17 20:17:23 ,. �T' Right-Suite®Universal201717.0.29RSU09479 Page 6 ...\Beaches Habitat\156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE 4 wrightsoft Right-J® Worksheet Job: 156 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bath 2 2 Exposed wall 9.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 5 Room area 54.0 ft' t I i I Ty Construction U-value Or HTM Area (ft') ' Load Area number (Btuh/ft'-°F I (Btuh/ft') or erimeter Load p (fl) (Btuh) � or perimeter I �IHeat ICool I Gross IN/P/S Heat I Cool ( Gross I N/P/S Heat I Cool 6 V/ 112E-Osw 0.068 ne 2.55 1.43 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 11 1D-c2ow 1D-c2ow 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0.570 se 21.38 38.87 0 0 0 0 0.570 se 21.38 24.12 0 0 0 0 1 D c2ow 0.570 se 21.38 18.20 0 0 0 0 D 11 DO 0.390 se 14.62 11.78 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 72 72 184 103 12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 D 11D0 0.390 nw 14.62 11.78 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 54 54 65 93 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 1 6 1 c)AED excursion 1 1 181 1 1 Envelope loss/gain 2481 178 12 a) Infiltration 135 33 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 384 211 Less external load 0 0 Less transfer 0 0 Redistribution 398 378 14 Subtotal 782 589 15 Duct loads 20% 20% 156 118 I I Air Totalrequireroomd load(cfm) I I I 9381 72081 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wright5aft Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-1720:17:23 Page 7 ...\Beaches Habitat\156 Sandy Beach Lane11140R.rup Calc=MJ8 Front Door faces:SE N 1 S IOOI' Utility Kitchen • bfi1 126 cfm 6 " 4 " 10 " 6 „ Aicfm Mech • 106 cfm 12 " Sup Riser ''• 12 " 6 " Great 'A 106 cfm Job#: 156 SB Lane Scale: 1 :48 Performed for: Florida Air Service & Engineering Page 1 Beaches Habitat 150 Hilden Road 308 RightSuite®Universal 2017 Ponte Vedra,Fl 32081 17.0.29 RSU09479 Phone:904-823-9696 2017-Oct-17 20:17:39 WWW.NORTHFLORIDAAIR.COM ...t\156 Sandy Beach Lane\1140... N /M.- ' 1 2nd Floor Bed 3 Bed 2 12 x 10 .44112 x 10 044 103 cf iz( 130 cfm 6 " 6 " Bath 2 •. up er 4 " 7 " ®` 12 10 01.4 , 167cfm ML',en Master ►.4 36 cf M WIC Job#: 156 SB Lane Scale: 1 :48 Performed for: Florida Air Service & Engineering Beaches Habitat Page 2 150 Hilden Road 308 Right Suite®Universal 2017 Ponte Vedra,Fl 32081 17.0.29 RSU09479 Phone:904-823-9696 2017-Oct-17 20:17:39 WWW.NORTHFLORIDAAIR.COM ...h156 Sandy Beach Lane\1140... - Duct System SummaryJob: 156 SB Lane - wrightsoftDate: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Heating Cooling External static pressure 0.25 in H2O 0.25 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply/return available pressure 0.125/0.125 in H2O 0.125/0.125 in H2O Lowest friction rate 0.100 in/100ft 0.100 in/100ft Actual air flow 700 cfm 700 cfm Total effective length(TEL) 126 ft Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath 1-A h 1782 59 28 0.100 4.0 Ox 0 VIFx 17.1 100.0 st3 Bath 2 h 938 31 28 0.100 4.0 Ox 0 VIFx 11.1 110.0 st2 Bede c 3248 101 130 0.100 6.0 0x0 VIFx 13.9 110.0 st2 Bed 3 c 2583 67 103 0.100 6.0 Ox 0 VIFx 15.0 110.0 st2 Great-A h 3192 106 49 0.100 6.0 Ox 0 VIFx 16.2 100.0 st3 Great-B h 3192 106 49 0.100 6.0 Ox 0 VIFx 25.2 100.0 st3 Kitchen c 3158 101 126 0.100 6.0 Ox 0 VIFx 12.2 100.0 st3 M WIC h 1086 36 19 0.100 4.0 Ox 0 VIFx 15.8 110.0 st2 Master-A c 4163 91 167 0.100 7.0 Ox 0 VIFx 11.4 110.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 373 252 0.100 685 10.0 0 x 0 VinIFIx st1 st1 Peak AVF 373 252 0.100 685 10.0 0 x 0 VinIFIx st2 Peak AVF 327 448 0.100 570 12.0 0 x 0 VinIFIx • Bold/italic values have been manually overridden 2017-Oct-17 20:17:24 .` wrightsoft Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 AAA ...\Beaches Habitat\156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE Return Branch Detail Table Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 700 700 0 0.080 655 14.0 Ox 0 VIFx 4 w Ightsoft' Right-SuiteeUniversal 201717.0.29RSU09479 2017-Oct-1720:17:24 `' Page 2 ...\Beaches Habitat\156 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE