160 SANDY BEACH LN - RES17-0234 new home permit d
xxz, IA CITY OF ATLANTIC BEACH
s1 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
051 cP INSPECTION PHONE LINE 247-5814
RESIDENTIAL - NEW SINGLE FAMILY ATTACHED
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: RES17-0234
Description: new attached single-family home
Estimated Value: 161178.7
Issue Date: 11/15/2017
Expiration Date: 5/14/2018
PROPERTY ADDRESS:
Address: 160 SANDY BEACH LN
RE Number: 173414 0185
PROPERTY OWNER:
Name: BEACHES HABITAT FOR HUMANITY INC
Address: 797 MAYPORT RD
ATLANTIC BEACH, FL 32233
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
Phone:
Name: 201 MAYPORT CONSTRUCTION MANAGEMENT
Address: 2768 STATE RD A1A#701
ATLANTIC BEACH, FL 32233
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
01.A, .,41 City of Atlantic Beach APPLICATION NUMBER
Js �� Building Department (To be assigned by the Building Department.)
v 800 Seminole Road LC
s) Atlantic Beach, Florida 32233-5445 �w1' 3
Phone(904)247-5826 • Fax(904)247-5845
'',j,3 gr E-mail: building-dept@coab.us Date routed: !01 (
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: tit 0 Safva4 Wt-h LA • Department review required Yes o
uildin /
Applicant: `°` k PO(-t CONStiLt6Di Planning & Zoninq�
Tree Administrator
Project: Ne--1-‘) o ktG Sl(\^ki— �`kiPublic Works—)
-ublic Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Review or Receipt
Other Agency Review or Permit Required Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: [pproved. [Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING
Reviewed by: Date: / "'7 0/7
TREE ADMIN. Second Review: EApproved as revised. ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ['Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
i1,AN-",,, City of Atlantic Beach APPLICATION NUMBER
S J s, Building Department (To be assigned by the Building Department.)
800 Seminole Road e-6C` _ (7- l`
0
iv -a r) Atlantic Beach, Florida 32233-5445 W 'mo ( '7
/ Phone(904)247-5826 • Fax(904)247-5845
0109 E-mail: building-dept@coab.us Date routed: lO
id)S(1 "1-
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 1ltD Sar\A i a[L k • Department review required Yes No
uildin
Applicant: a`0` 1' 1/4-tpU(A" CDt\Sfi(u.601) Plannin. &Zonin
Tree Administrator
Project: Ne. t k) k-\-4{,kali S\(T1,i— tk( Public Works
�J (ublic Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ,❑Approved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by:d- /A..., Date:( -3 —/7
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
rrS� City of Atlantic Beach APPLICATION NUMBER
r' ,, _ •S Building Department (To be assigned by the Building Department.)
9 800 Seminole Road p �C C1- -
� .- 3 l`
y� r f—W mo ( -1
Atlantic Beach, Florida 32233 5445 OCT6 2017
\� � z
Phone(904)247-5826 • Fax(904)247-5845
--.4,„ ,....?/ E-mail: building-dept@coab.us Date routed: !O1. (I '-1--
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: U. 0 S ,AALI YJ( .h LA • Department review required Yes No
uilding)
Applicant: ' - ' i ktpo(a- Canstitk6o. Plannin &Zonin
(�- Tree Administrator
Project: Y\LL(,-3 GI 5IN,5kQ— l(vv.\,\l Public Works)
ublic Utilities)
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Approved. (Denied. Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING �/�-j
Reviewed b Date:`0.movi //
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. [— Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
-/I-AZ::,,, City of Atlantic Beach APPLICATION NUMBER
fir'
i, Building Department (To be assigned by the Building Department.)
s� 800 Seminole Road p LC` - /�}�3
�� Atlantic Beach, Florida 32233-5445 f—Wmo (
Phone(904)247-5826 • Fax(904)247-5845 Qcj 2 g 2017 �� �,
Lf
;;319? E-mail: building-dept@coab.us Date routed: iD
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 1,I 0 S1naL/ WALi/ LA • Department review required Yes No
uilding)
Applicant: aO\ yviktpo(-F CO Stilk , 01) Plannin &Zoninci
f Tree Administrator
Project: i\-e-)-3 Ct.M(, S11\ — 0.N ‘Al c. rublic Works
�lA�.Q
(Public Utilities
Public Safety
Fire Services
Review fee $ - 97-° Dept Signature X v�
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Vroved. Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: 4-",.......a.
''rte Date: (( / 3/ 7
TREE ADMIN. Second Review: ['Approved as revised. ❑Denied. ❑Not applicable
PUB ORKSComments:
• 4.-4--
BLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ['Not applicable
Comments:
Reviewed by: _Date:
r
Revised 05/19/2017
BUILDING PERMIT APPLICATION
CITY OF ATLANTIC BEACH OFFICE COPY
800 Seminole Road, Atlantic Beach, FL 32233
Office (904) 247-5826 Fax (904) 247-5845
Job Address: # 160 Sandy Beach Lane, COAB, 32233 Permit Number: 1`- .S L 1_ 0 3�
Legal Description: 38-2529E-7.41B De Castro Y Ferrr Grant PT RECD O/R 16531-2248 Parcel #Blk: 1 Lot: 6
Floor Area of Sq.Ft. Sq Ft
Valuation of Work $110,000 Proposed Work heated/cooled 1358. non-heated/cooled 164
Class of Work(circle one): New (X) Addition Alteration Repair Move Demolition pool/spa window/door
Use of existing/proposed structure(s) (circle one): Commercial Residential
If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No(X) N/A
Florida Product Approval #
For multiple products use product approval form
Describe in detail the type of work to be performed: Construct attached two story Quad- single family homes
Property Owner Information:
Name: Beaches Habitat for Humanity Address: 797 Mayport Rd
City Atlantic Beach State FL Zip 32233 Phone#904-241-1202
E-Mail or Fax#(Optional)#904-241-4310, rpeterson(abeacheshabitat.org
Contractor Information:
Company Name:201 Mayport Construction Management, LLC Qualifying Agent: Robert Peterson
Address: 2768 State Rd.AlA#701 City Atlantic Beach State FL Zip 32233
Office Phone 904-595-5798 Job Site/Contact Number 904-334-1202 Fax#
State Certification/Registration#CGC 1506666
Architect Name&Phone# til\,C,or.sr\R2, CI\f e r\n-1 q0L1- 1Oy- bU V6
Engineer's Name& Phone# On‘ck\O-Q.\ C01y Vr,r- lade c olvy- t4?l) - is L1`1
Fee Simple Title Holder Name and Address
Bonding Company Name and Address
Mortgage Lender Name and Address
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null
and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six_(6)months at any time after
work is commenced. I understand that separate permits must be secured for ElectricalpWork, Plumbing,Signs, Wells, Pools, Furnaces, Boilers,Heaters,
Tanks and Air Conditioners,etc.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
I herebycertify that I have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this
type of ork will be c••rplied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the
provisions of any other •deral,state,or local law regulating construction or the performance of construction.
Signature of Owner l i/ id • Signature of Contractor
iir
Print Name .40 ' Print Name 4.C.a. - Ceci
Sworn to and subscribed before me Sworn to and subscribed before me
this Ili-Day of s< I ,20 11 this MI-Day of Sti r ,20 1-7
Notary Public - - - - - - // _ Notary Public
"""""••, KYLE MURRAY
°��n�" �`av"''• KYLE MURRAY
4 :'� .:- Notary Public-State of Florida ( �� `�'� Re�iSed 01.26.10
• ?° `� NotaryPublic-StateofFloridaCommission 0 FF 941841 i .� I1 ��y � �? ‘11,44-1.1:--40),
Commission#F FF 941841
My Comm.Expires Apr 2,2020 4 ;9 "' �= I
"�};,oc��,.• ,,, ��� ac My Comm.Expires Apr 2,2020
Bonded through National Notary Assn. 0 4/cc"(I`� Bonded through National Notary Assn. 0
, 201
Mr. Kayle Moore
Public Utilities Director
City of Atlantic Beach
1200 Sandpiper Lane
Atlantic Beach, FL 32233
Mr. Moore
I have submitted a building permit application for the Quad "B"" located at:
#156,160,164,168 Sandy Beach Lane, COAB (Blk. # 1, Lots#4,5,6,7) Beaches
Habitat will not be installing a fire sprinkler in this structure. In addition, according to
our HOA agreement we will be installing an irrigation system for the common areas.
Please give me a call (904-241-1222, or 334-1202) if you require any additional
information.
Sincerely,
Re
Construction Director
City of Atlantic Beach
PUBLIC UTILITIES DEPARTMENT
it j 1200 Sandpiper Lane
Atlantic Beach, FL 32233
(904) 247-5834
NEW WATER / SEWER TAP REQUEST
Date / / — 2 — (-7 Project Address / 0 S7 ov ec '/j Ccg/�JT
Number of Units !' Commercial Residential Multi-Family
New Water Tap(s) & Meter(s) Meter Size(s) 34.1
New Irrigation Meter Upgrade Existing Meter from to (size)
New Reclaim Water Meter Size New Connection to City Sewer
Applicant Name
Applicant Address
City State Zip
Phone Cell
Email
Applicant Signature
CITY STAFF USE ONLY
Application# ?cS 17 — Z 3(-{ fro/� -
A: e1/F (i4
Water System Development Charge $
Sewer System Development Charge $ /V d SWC S / (
Water Meter Only $ / R T CSO
Reclaim Meter Only $
Water Meter Tap $
Sewer Tap $
Cross Connection $ L. 6O
Other $
TOTAL $ 3 ST 60 (Notes)
APPROVED Kayle Moore, P.E. Date 22/7
Public Utilities Director or Authorized Signature
ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED
Permit Attachment of
Permit# —__for
issued ,20 Atlantic Beach,FL 32233
Owner's Name: t .A.e. ,cam
R.E.#: • Property Address:
Subdivision: t � /
Lot#/Block #: .}� �
REVOCABLE ENCROACHMENT PERMIT
THIS REVOCABLE ENCROACHMENT PERMIT
by Atlantic Beach, ,issued on this day of
Florida, a municipal corporation organized2e of
Florida, hereinafter referred to as "CITY" and existing ,
hereinafter referred to as "USER". and I.ss , g under the laws of the State a,
of Atlantic Beach, Florida,
WITNESSETH:
That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to
Pon the property of the City of Atlantic Beach for the
Beach Right-of-Way/Easement permit numbers noted above(copies ttached)describedose as in the City of Atlantic
This work is generally described as:
• l l • � e( Uc wk.
Any facility maintained, repaired, erected,
subject to relocation or removal dn and/or installed in the exercise of the privilege
thirty(30 daysgrantedEremains
e
Evan by certified ..mail ) notice by CITY to the USER, said notice to USER shall be
–1 3 '• return receipt requested, to the following address:
a
The depositing of said notice of cancellation in
cancellation and the burden is upon USER to keepthe CITY UnitediifStates mail shall constitute the notice of
The USER shall promptly make any and all n unformed of USER's proper address.
exercise of the ge herein necessary repairs to any facility erected or maintained in the
granted and shall at all times maintain said facility in good and safe condition.
In the event it is necessary for the CITY or the City's approved pp owed representative or other franchised utility to
enter upon the above-described property of the CITY
any and all material necessarily displaced Burin ' the USER shall replace at the USER's sole expense
action of maintaining,provider.
repairing, operating, replacing, or
adding to of the utilities and facilities of the CITY or
franchise utility prov
The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes,
Land Development Code, and all other land use and code requirements of the CITY,
City Code Section 19-7 including
(h)which states"Driveways that cross sidewalks: City sidewalks may not be replaced
left na
with other materials, but must be replaced with smooth concrete
existing and adjoining sidewalks." tural in color so that it matches the
Page 1 of 2
The USER, prior to making any changes from the approved plans and/or
approval from the Cityoof AtlanticgaBeach,c
discretion the CITY, brequessubmitblas-built
Department,
e a method,The must USER shall,a written
top rtgs for said change. at the
after the day of completion. vcnngs showing
e the change within thirty (30) days
p rmit shall insure to the benefit of, and be binding upon, the USER and their r
Thissigns.
•
respective successors and
USER shall meet the terms and conditions of this permit and to all of the
and/or specifications, to include utilities locate requirements and use limitations/requirements
• rights-of-way and other public land. applicable State and CITY laws
be saved hUSER further agrees that the CITY and itsoffi officers and employees shall
armless bypublic
liabilities are hereby assumed d b from any of the work herein under the terms of this e
y the USER. permit and that all of said
I �TED and SIGNED this
day of 201.7
By: I „A �
'e + �wne r•��M'''•'' KYLE MURRAY
(to be ¢'= Notary Public-State of Florida
in presence of the Notary) '.'`.' Commission#FF 941841
STATE
1..N.,. �-F�?,�' My Comm.Expires Apr 2,2020
OF FLORIDA Bonded through National Notary Ass- `"
COUNTY OF DUVAL 7
On this day of /`�_
... ,...---,,?::5,-------
and for said County and ' 20 Personally appeared before me, a No
State,
the Notary Public in
oin 'Atlantic Beach, Florida property owner of
known to me to be the (s)described in
and who executed the fore
and voluntaril foregoing instrument; who acknowledged to me that he or she executecutedd the same freely
y and for the uses and purposes therein mentioned,
Notary Public in for said County and State
CITY OF ATLANTIC BEACH, FLORIDA a
municipal corporation: '
Approved:
. ,gid/
-_*---'7"- 71"-'..,..!!i.'- i -�` is'—mut'
i!
/ Pub is Y1 or s iirector
For ermits where city sidewalk is impacted,
City Manager approval required:
Nelson Van Liere,City Manager
Page 2 of 2
.
C
CITY OF ATLANTIC BEACH
EACH
o ��r, CONSTRUCTION PERMIT WITHIN
s� ��-� 800 Seminole Road
���- ' Atlantic Beach,Florida 32233.5445 AND EASEMENTS
PLEASE SUBMiCOMpLETE SETS OF P
904-247-5800
Date
PLANS WITH APPLICATION. Fax 904-247-5845
Job Address ' ,O •R ,
�.. PERMIT#
Permitee: 2 b
'"�a� l�'✓f C.,,Nsc fiISSUED BY THE CITY
rs. V�1w"'��5t'Nt..1
Telephone# c y _ 3
Permittee Address: Z
(. LX
Requesting Permission to Construct:
� 33
✓Y iv-,
"� °t •
`"u
(Reference to Cross Street) Q•0 .
nt declares that prior to filing5.14..b` „ -4.,
`� , i
both aerialnand underground and the accurate locations are ��
1. Applicant
this application heehas ascertained the location of all existing utilities,
A Lefler of Notification was mailed to the following
shown on the sketches.
Jacksonville Electric Authority Utilities/Municipalities:
Bell South Telephone Company
Ferrell Gas Yes( ) No ( ) Date:
Comcast Yes( ) No ( ) Date:
2. Whenever necessary Yes( ) No ( ) Date:
ry for the construction, Yes( ) No ( ) Date:
alteration or of or any repair, improvement, maintenance, safe and e
any relocation all of saidf all, portion of said street or easement as determined by
hereunder, Poles, wires efficient operation,
shall be immediately removed from said street or easement pipes, cables or other facilities and a the Director of Public
required by the Director of Public appurtenances authorized
authorized. Works, and at the expense orm reset l relocatedseen as
3. All work shall meet City of the Permittee unless reimbursement is
All Work of Atlantic Beach or Florida De
under the supervision of
Superintendent) located at e.�- Department of Trans
4. � .{�,,,� �.,` Transportation Standards and be
All materials and equipment shall be su '
5. All city ect to inspection b (Contractor's Project
ty property shall be restored to its original condition as far as Telephone#: qoy_ _
and the manner satisfactory Y the Director of Public Works or his 3 y rto
6 A, of r!'to the city. practical, in keeping designee.
plans covering of this installation P 9 with city specifications
part sketchof permit.covering
detailsens sof this , as Well as, a co
pyparRi t this are to be iucluons with Phis an increase in im, us arf e recentnoserve
7. This permittee shall commence actual construction in cruises area on owner's lot oy lr bel themGeta.
more thanr60 days from date of lon in g.
topermit approval, good faith with
B. no haeoccurrednn the area that would days. If the beginning date is
It Public Worksrand make sureed that changestne rights and Permittee must review the
It iss's right, title and interest in the land ht be entered upon permit with the Directort of of
Ci
times, assume all risk of and indemnitofy, privileges herein set out are affect the permitted construction.
against any and all loss, damage, P and used bygranted only to the extent of the
fy, defend, and save harmless hen holder, and the Holder will, at all
byg , and cost of expenses arisingin anyCityof
9. exercisese Ditheoolder of the
Worksa shall idei PAtlantic Beach from and
rights and privileges. manner of the exercise
immedi.tely upon completion. notifiedor attempted
twenty-four (24) hours prior to starting 9 work and again
Signed: 1113 a a•,,�,,,,,
WIPP p —7 ,,•;�►'"Y�e��,, KYLE MUgRAY
Before me this = Date: i °I / _ Now pubpc
Before
State Of Florida day ofd�2(_ --- $�t0 Of Fbrlda
Notaryhas personally appeared `T�--in the County of Duv %j "� COmmlt=Ips Or FF 9��S,f
Public at Large,State of Florida,County of Duval. �' d on Comm.
My commission expires: °'�.°;;;���`'�� Expire:Apr 2,2020
Bonded through National Notary Assn
Produced Identification:
Pe,sonally Known. ,
y
•
DO NOT WRITE BELOW- OFFICE IJSE ONLY
Applzca. e Co.es: 2010 FLORIDA BUILDING CODE
Review Result circle one :
Approved Disapproved
Approved'w/ Conditions
Review Initials/Date:
beyelopment Size
Habitable Space / 3 5 Sr Non-Habitable 100 S F
nap ervious area
Tiscellaneous Information
ccupancy Group (12 e3
ype of Construction v (j
.tuber of Stories 2-
fling
Hing District k G
x. Occupancy Load
Sprinklers Required •
�d Zone X
diti ons/Comm eats:
i l
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA
Project Name: OceanGate: Quad "B" Permit#RES/7-0.13 y OFFICE C0PY
Project Address: #156,160,164,168 Sandy Beach Lane, COAB, 32233
As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and product approval
number(s) for the building components listed below as applicable to the building construction project for the permit number listed
above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed
products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org.
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local #
A. EXTERIOR DOORS
1. Swinging Masonite Steel Door FL4904
2. Sliding
3. Sectional
4. Roll up Clopay Garage Door- HDG FL5684.10
5. Automatic
6. Other
B. WINDOWS
1. Single hung Atrium Single Hung Window FL11834.10
2. Horizontal slider
3. Casement
4. Double hung
5. Fixed
6. Awning
7. Pass-through
8. Projected
9. Mullion
10. Wind breaker
11.. Dual action
12.. Other
r Z
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA
C. PANEL WALL
1. Siding James Hardie Cemplank siding FL13192.1
2. Soffits Crane Vinyl Soffit FL2495-R 1
3. EIFS
4. Storefronts
5. Curtain walls
6. Wall louvers
7. Glass block
8. Membrane
9. Greenhouse
10. Synthetic stucco Acrocrete Synthetic finish coat
11. Other
D. ROOFING PRODUCTS
1. Asphalt shingles GAF 30 yr architectural FL10124
2. Underlayments RhinoRoof Syn. Underlayment FL15216
3. Roofing fasteners
4. Nonstructural metal roof Millenia Metals Form rolled metal FL5211.2
R4
5. Built-up roofing _
6. Modified bitumen Certainteed Flintlastic SA FL2533
7. Single ply roofing
8. Roofing tiles
9. Roofing insulation
10. Waterproofing
11. Wood shingles/shakes
%
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA
12. Roofing slate
13. Liquid applied roofing
14. Cement-adhesive coasts
15. Roof tile adhesive
16. Spray applied polyurethane
roof
17. Other
E. SHUTTERS
1. Accordion Shutter Shield Accordion FL9569.1
2. Bahama
3. Storm panels Madden Mfg. Storm Panels FL5329.1
4. Colonial
5. Roll-up
6. Equipment
7. Other
F. STRUCTURAL
COMPONENTS
1. Wood connector/anchor Simpson Strong- H16S FL 1423.6
Tie MTS 12 FL474.253
2. Truss plates MiTek Industries Truss Plates FL2197
3. Engineered lumber Tus-Joist- Engineered Lumber FL1630
Weyerhauser
4. Railing
5. Coolers-freezers
6. Concrete admixtures
7. Material
8. Insulation forms
9. Plastics
10. Deck-roof
11. Wall
it. y
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA
12. Sheds
13. Other
G. SKYLIGHTS
1. Skylight
2. Other
H.NEW EXTERIOR
ENVELOPE PRODUCTS
1.
2.
In addition to completing the above list of manufacturer,product description and State approval number for the products used on this
project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions,
along with the list above, on the job site available to the inspector.
The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be
inspected, they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to
include each new product in the categories listed above and will be highlighted to indicate the new products and required information.
Authorized Project Agent: Robert Peterson; Director of Construction
(Contractor or Design Professional) (Print Name) (Signature)
Company Name: Beaches Habitat for Humanity
Mailing Address: 797 Mayport Road
^- s
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA
City: Atlantic Beach State: FL Zip Code: 32233
Telephone Number: ( 904) 241-1222 Fax Number: (904 ) 241-4310
Cell Phone Number: ( 904) 334-1202 E-mail Address: rpetersonAbeacheshabitat.org
( JO se,
OFFICE COPY
FORM R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
E l A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, e-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page) and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
E l Energy Performance Level(EPL) Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge®-USRCZB v5.1
9/19/2017 9:21:01 AM Page 1 of 1
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HABITAT-QUADPLEX-INSIDE-160 SB Builder Name: BEACHES HABITAT
Street: 160 SANDY BEACH LANE Permit Office: DUVAL COUNTY
City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number:
Owner: Jurisdiction: 261300
Design Location: FL,Jacksonville County:: DUVAL(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1920.0 sqft.) Insulation Area
2. Single family or multiple family Multi-family a.Frame-Wood,Common R=19.0 1392.00 ft2
b.Frame-Wood,Exterior R=19.0 528.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (605.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 605.00 ft2
6. Conditioned floor area above grade(ft2) 1358 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(105.1 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165
a. U-Factor: Dbl,U=0.30 105.06 ft2
SHGC: SHGC=0.30
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 24.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Heat Pump 24.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.049 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (605.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 EF:0.920
b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.077 Total Proposed Modified Loads: 25.90 PASS
Total Baseline Loads: 28.40
I
hereby certify that the plans and specifications covered by Review of the plans and OtIYiE Sr* .,
this calculation are in compliance with the Florida Energy specifications covered by this :EA-. .1/4' r,,, p *,.
Code. calculation indicates compliance '`,, ,,�''�'•`=. :',o'.'{,,=.
f,f, "'.14
with the Florida Energy Code. /�'*�urh, ", ;::,?*!,'„•"'-•“, 1.
PREPARE BY. A. WILKERSON Before construction is completed c `''' �' 's:
9/19/2017 ' rx. . ...:,. r»
DATE: this building will be inspected for a )lii - •0 I
compliance with Section 553.908 ?; ,
I hereby certify that 's buildin as designed, is in compliance Florida Statutes. f+' �r ;;S
_ COD X103..
with the Florida Energ o
to
OWNER/AGENT:
BUILDING OFFICIAL: iri
DATE: Q 2'17 DATE: /l - 7-/
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017
this project requires an envelope leakage test report with envelope leakage no greater than 3.0 ACH50(R402.4.1.2).
- Compliance requires a roof emittance test in accordance with R405.7.2
9/19/2017 9:21 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
PROJECT
Title: HABITAT-QUADPLEX-INSID Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1358 Lot#
Owner: Total Stories: 2 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: BEACHES HABITAT Rotate Angle: 0 Street: 160 SANDY BEACH LA
Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL
Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH ,
Family Type: Multi-family FL, 32233
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Block1 1358 10864
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated
1 1st Floor 805 6440 Yes 0 0 1 Yes Yes Yes
2 2nd Floor 553 4424 No 4 3 1 Yes Yes Yes
FLOORS
V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge lnsulatio 1st Floor 190 ft 0 605 ft2 ___ 0.2 0 0.8
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Composition shingles 638 ft2 100 ft2 Medium 0.75 No 0.9 Yes 0 18.4
V ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 605 ft2 N N
CEILING
V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 1st Floor 30 Batt 605 ft2 0 Wood
9/19/2017 9:21 AM EnergyGaugee USA-v5.1-Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
#
Adjacent Cavity Width Height Sheathing Framing Solar Below
Omt Wall Space Type P R-Value Ft In Ft In Area R-Value Fractinn Ahcor (rarle%/
1 N Exterior Frame-Wood 1st Floor 19 16 6 8 132.0 ft2 0.23 0.75 0
2 E Neighbor Frame-Wood 1st Floor 19 52 0 8 416.0 ft2 0.23 0.75 0
3 S Exterior Frame-Wood 1st Floor 19 16 6 8 132.0 ft2 0.23 0.75 0
4 W Neighbor Frame-Wood 1st Floor 19 52 0 8 416.0 ft2 0.23 0.75 0
5 N Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft2 0.23 0.75 0
6 E Neighbor Frame-Wood 2nd Floor 19 35 0 8 280.0 ft2 0.23 0.75 0
_ 7 S Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft2 0.23 0.75 0
8 W Neighbor Frame-Wood 2nd Floor 19 35 0 8 280.0 ft2 0.23 0.75 0
DOORS
V # Omt Door Type Space Storms U-ValueFt Width In FtWidthArea
1 N Insulated 1st Floor Metal .46 3 6 8 20 ft2
2 S Insulated 1st Floor Metal .46 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None
2 N 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None
3 S 3 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None
4 N 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
5 N 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5112 1 ft 0 in 1 ft 0 in Drapes/blinds None
6 S 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
7 S 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
INFILTRATION
# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000152 543.2 29.82 56.08 .1446 3
HEATING SYSTEM
V # System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.5 24 kBtu/hr 1 sys#1
COOLING SYSTEM
V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:15 24 kBtu/hr 720 cfm 0.75 1 sys#1
9/19/2017 9:21 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
HOT WATER SYSTEM
V # System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— --Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling X Jan Feb X Mar X Apr X May Jun X Jul X Aug X Sep X Oct Nov X Dec
HeVenting �X�Jan I))1
Feb X�Mar �X�Apr X�Mar X y 1)X1
Jun X�Jul �X�AuJun X Jul X g �X�Sep X�Oct 1Xxi
Nov X�Dec
Thermostat Schedule: FloridaCode 2014 Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75
PM 75 75 75 75 75 75 75 75 75 75 75 75
Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75
PM 75 75 75 75 75 75 75 75 75 75 75 75
Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72
PM 72 72 72 72 72 72 72 72 72 72 72 72
Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72
PM 72 72 72 72 72 72 72 72 72 72 72 72
9/19/2017 9:21 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
160 SANDY BEACH LANE, ATLANTIC BEACH , FL, 32233
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Multi-family a. Frame-Wood,Common R=19.0 1392.00 ft'
b.Frame-Wood, Exterior R=19.0 528.00 ft'
3. Number of units,if multiple family 1 c. N/A R= ft'
4. Number of Bedrooms 3 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 605.00 ft'
6. Conditioned floor area(ft2) 1358 b.N/A R= ft2
7. Windows*' Description Area c. N/A R= ft'
a. U-Factor: Dbl,U=0.30 105.06 ft2 11.Ducts R ft'
a.Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165
SHGC: SHGC=0.30
b. U-Factor: N/A ft'
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a,Central Unit 24.0 SEER:15.00
SHGC:
d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency
SHGC:
Area Weighted Average Overhang Depth: 3.049 ft. a. Electric Heat Pump 24.0 HSPF:8.50
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14.Hot water systems
2 a. Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft EF:0.92
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building r""'"-"""''•-�:
Construction through the above energy saving features which will be installed (or exceeded) ..4 oF'_1NE.STq�Fo�,
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �<vQ;; ' �.•-> ;,.
based on installed Code compliant features. r I.:+, ,, .`. "., ,- o
.„mel.p
Builder Signature: �. _ 1' -= Date: 7 A, c.."(-- 7 :c�:._, a
_
Address of New Home: 16,D j. Y3'v_poit. . City/FL Zip: ( (.1_, ---' ^%.4%-... . ....4 +-
13
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/19/2017 9:21 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
•
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: 160 SANDY BEACH LANE Permit Number:
ATLANTIC BEACH , FL, 32233
MANDATORY REQUIREMENTS See individual code sections for full details.
O 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit,The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
O R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
▪ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour in Climate Zones 1 and 2.and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Testing shall be conducted by either individuals as defined in Section
553.993(5)or(7), Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A
written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2. Dampers including exhaust, intake, makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors, if installed at the time of the test,shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMANVDMA/CSA 101/I.S.2/A440 by an accredited.independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
O R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
O R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing(Mandatory)All ducts, air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7),
Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"by either of
the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g. (25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
9/19/2017 9:22 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
O R403.4.4.1 Storage water heater temperature controls
▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
. R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1.Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6.or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
9/19/2017 9:22 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal, rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
▪ R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and 0404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
O R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2. Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
• solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
O R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space, R-10 is allowed.
9/19/2017 9:22 AM EnergyGauge&USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: HABITAT-QUADPLEX-INSIDE-160 SB Builder Name: BEACHES HABITAT
Street: 160 SANDY BEACH LANE Permit Office: DUVAL COUNTY
City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number:
Owner: Jurisdiction: 261300
Design Location: FL,Jacksonville
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
9/19/2017 9:22 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: HABITAT-QUADPLEX-INSIDE-160 SB Builder Name: BEACHES HABITAT
Street: 160 SANDY BEACH LANE Permit Office: DUVAL COUNTY
City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number:
Design Location: FL,Jacksonville Jurisdiction: 261300
Cond. Floor Area:: 1358 sq.ft. Cond.Volume: 10864 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data: CFM(50):
C: n: R:
ELA:
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: EqLA:
1 Pa cfm ACH:
2 Pa cfm SLA:
3 Pa cfm
ACH(50) * :
4 Pa cfm
* For prescriptive projects, tested leakage must be
5 Pa cfm <=7 ACH(50). For performance projects, tested
6 Pa cfm leakage must be<=the ACH(50) shown on Form
R405-2014 for this project.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour
in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Testing shall be conducted by
either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake,makeup air,backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration
control measures:
3. Interior doors, if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers, if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage estidu shall be conducted by either #.•' TyIE ST
individuals as defined in Section 0 rF''+.
performance results demonstrate compliance ' v; ''n . 4 0 .
with Florida EnergyCode requirements in 553.993(5) or(7), Florida Statutes or ?��$':''�%,; t,
individuals licensed as set forth in �,.,,,�,
accordance with Section R402.4.1.2. ; , .`
Section 489.105(3)(f), (g), or(i) or an �,•_
approved third party. A written report
SIGNATURE: of the results of the test shall be signed .'.. • ;1 ;+
by the third party conducting the test .t)41 -
'' "my-: SS
and provided to the code official. '�,GOp y......PRINTED
PRINTED NAME: �.�.•,,,,a
BUILDING OFFICIAL:
DATE:
DATE:
9/19/2017 9:22 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1
Residential System Sizing Calculation
Summary
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233
9/19/2017
Location for weather data: Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M)
Humidity data: Interior RH (50%) Outdoor wet bulb (77F) Humidity difference(49qr.)
Winter design temperature(TMY3 99%) 29 F Summer design temperature(TMY3 99%) 95 F
Winter setpoint 70 F Summer setpoint 75 F
Winter temperature difference 41 F Summer temperature difference 20 F
Total heating load calculation 15129 Btuh Total cooling load calculation 7547 Btuh
Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh
Total (Electric Heat Pump) 158.6 24000 Sensible (SHR=0.75) 315.7 18000
Heat Pump + Auxiliary(0.0kW) 158.6 24000 Latent 325.1 6000
Total (Electric Heat Pump) 318.0 24000
WINTER CALCULATIONS
Winter Heating Load (for 1358 sqft)
Load component Load
Window total 105 sqft 1292 Btuh weiis(s.o%
Wall total 383 sqft 1213 Btuh ceilings(52%)
Door total 40 sqft 754 Btuh
Ceiling total 605 sqft 790 Btuh V indo'rrs(8.5%)
Floor total 605 sqft 9192 Btuh
Infiltration 42 cfm 1887 Btuh
Duct loss 0 Btuh Fioors(60.8%)
Subtotal 15129 Btuh InfL(12.5%)1
Ventilation 0 cfm 0 Btuh
TOTAL HEAT LOSS 15129 Btuh
Doors(5.4%)
SUMMER CALCULATIONS
Summer Cooling Load (for 1358 sqft)
Load component Load
Window total 105 sqft 952 Btuh
Wall total 383 sqft 663 Btuhu�
Fall;(-878%—)1 115%
s '
Door total 40 sqft 409 Btuh Ceilin 9 ( )
Ceiling total 605 sqft 867 Btuh Doors(5.4%)
Floor total 0 Btuh
Infiltration 31 cfm 690 Btuh Windovrs(12.6%)
Internal gain 2120 Btuh
Duct gain 0 Btuh Infil.(23.0%)1
Sens. Ventilation 0 cfm 0 Btuh
Blower Load 0 Btuh
Total sensible gain 5701 Btuh
Latent gain(ducts) 0 Btuh Latent int(19.6%)
Latent gain(infiltration) 1046 Btuh
Latent gain(ventilation) 0 Btuh
Latent gain(internal/occupants/other) 800 Btuh Int.Gain(28.1%)
Total latent gain 1846 Btuh
TOTAL HEAT GAIN 7547 Btuh
EnergyGauge®System Sizing
Pionib
8th Edition PREPARED BY:
DATE:
MIRK,
-nuumP• EnergyGauge®/USRCZB v5.1
Residential Window Diversity
MidSummer
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233
9/19/2017
Weather data for: Jacksonville -Defaults
Summer design temperature 95 F Average window load for July 1379 Btuh
Cooling setpoint 75 F Peak window load for July 1741 Btuh
Summer temperature difference 20 F Excusion limit(130%of Ave.) 1793 Btuh
Latitude 30.5 North Window excursion (July) None
WINDOW Average and Peak Loads
1,$"'t3 ■ m.mul:alli . .W
1,60D o'
...a
i
� 't awe a-_.• ,�..•�L_•I
.l..:i...�._,,
E I
.� •
1
1 rs
:`51V t
■
[8 R
1.:kL
Y
Y
A.60D '...
S la 12 14 16 18 20
LWindow Load (Btuh) —•—• Limltfor excursion
12 Hour Average
Total July Window Load(Radiation and conduction)
The midsummer window load for this house does not exceed the window load excursion limit.
This house has adequate midsummer window diversity.
/rani h
EnergyGauge®System Sizing for Florida residences only
PREPARED BY:
DATE: MRktJ(11.J
remr
EnergyGauge®/USRCZB v5.1
Residential Window Diversity
October
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233
9/19/2017
Weather data for: Jacksonville -Defaults
Summer design temperature 95 F Average window load for October 1629 Btuh
Cooling setpoint 75 F Peak window load for October 2310 Btuh
Summer temperature difference 20 F Excusion Iimit(130%of Ave.) 2117 Btuh
Latitude 30.5 North Window excursion (October) 192 Btuh
WINDOW Average and Peak Loads
-.-.-4
2.2O 0"
1,800
�y D t
1.L
Y Y
1, `�►
8D" •
l v `s
$ 12 14 16 18 20
—•—• WindowLoad (Btuh) —•—• Limltfarexcursion
12 Hour Average
Total October Window Load(Radiation and conduction)
Warning:This application has glass areas that produce relatively large heat gains for part of the day. Variable
air volume devices may be required to overcome spikes in solar gain for one or more rooms.A zoned system
may be required or some rooms may require zone control.
EnergyGauge®System Sizing for Florida residences only
PREPARED BY:
DATE: t1RRURI J
Niamsr-
EnergyGauge®/USRCZB v5.1
System Sizing Calculations - Winter
Residential Load - Whole House Component Details
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233 Building Type: User
9/19/2017
Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 41.0 F (TMY3 99%)
Component Loads for Whole House
Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load
1 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh
2 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh
3 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh
4 2, NFRC 0.30 Vinyl 0.30 N 15.5 12.3 191 Btuh
5 2, NFRC 0.30 Vinyl 0.30 N 15.5 12.3 191 Btuh
6 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh
7 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh
Window Total 105.1(sgft) 1292 Btuh
Walls Type Ornt. Ueff. R-Value Area X HTM= Load
(Cav/Sh)
1 Frame-Wood -Ext (0.077) 19.0/0.0 84 3.17 268 Btuh
3 Frame-Wood - Ext (0.077) 19.0/0.0 97 3.17 306 Btuh
5 Frame-Wood -Ext (0.077) 19.0/0.0 101 3.17 320 Btuh
7 Frame-Wood - Ext (0.077) 19.0/0.0 101 3.17 320 Btuh
Wall Total 383(sqft) 1213 Btuh
Doors Type Storm Ueff. Area X HTM= Load
1 Insulated - Exterior, m (0.460) 20 18.9 377 Btuh
2 Insulated -Exterior, m (0.460) 20 18.9 377 Btuh
Door Total 40(sgft) 754Btuh
Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load
1 Vented Attic/L/Shing (0.032) 30.0/0.0 605 1.3 790 Btuh
Ceiling Total 605(sgft) 790Btuh
Floors Type Ueff. R-Value Size X HTM= Load
1 Slab On Grade (1.180) 0.0 190.0 ft(perim.) 48.4 9192 Btuh
Floor Total 605 sqft 9192 Btuh
Envelope Subtotal: 13242 Btuh
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM=
Natural 0.23 10864 1.00 41.9 1887 Btuh
Duct load Average sealed, R6.0, Supply(Con), Return(Con) (DLM of 0.000) 0 Btuh
All Zones Sensible Subtotal All Zones 15129 Btuh
EnergyGauge®/USRCZB v5.1 Page 1
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233 Building Type: User
9/19/2017
�IIIHOLE HOUSE TOTALS
Subtotal Sensible Heat Loss 15129 Btuh
Totals for Heating Ventilation Sensible Heat Loss 0 Btuh
Total Heat Loss 15129 Btuh
EQUIPMENT
1. Electric Heat Pump # 24000 Btuh
milmorif
Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values)
or-Glass as'Clear or'Tint'(Uses U-Factor and SHGC defaults)
U-(Window U-Factor) ,
HTM-(Manual)Heat Transfer Multiplier)
Version 8
EnergyGauge®/USRCZB v5.1 Page 2
System Sizing Calculations - Summer
Residential Load - Whole House Component Details
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233
9/19/2017
Reference City: Jacksonville, FL Temperature Difference: 20.0F(TMY3 99%) Humidity difference:49gr.
Component Loads for Whole House
Type* Overhang Window Area(sqft) HTM Load
Window Panes SHGC U InSh IS Omt Len Hgt Gross Shaded Unshaded Shaded Unshaded
1 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.011 13.8 0.0 13.8 9 9 123 Btuh
2 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 13.8 0.0 13.8 9 9 123 Btuh
3 2 NFRC 0.30,0.30 B-L No S 6.0ft 1.Oft 15.5 15.5 0.0 9 11 139 Btuh
4 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 15.5 0.0 15.5 9 9 139 Btuh
5 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 15.5 0.0 15.5 9 9 139 Btuh
6 2 NFRC 0.30,0.30 B-L No S 1.0ft 1.0ft 15.5 12.6 2.9 9 11 145 Btuh
7 2 NFRC 0.30,0.30 B-L No S 1.0ft 1.0ft 15.5 12.6 2.9 9 11 145 Btuh
Window Total 105(sqft) 952 Btuh
Walls Type U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
1 Frame-Wood-Ext 0.08 19.0/0.0 84.4 1.7 146 Btuh
3 Frame-Wood-Ext 0.08 19.0/0.0 96.5 1.7 167 Btuh
5 Frame-Wood-Ext 0.08 19.0/0.0 101.0 1.7 175 Btuh
7 Frame-Wood-Ext 0.08 19.0/0.0 101.0 1.7 175 Btuh
Wall Total 383(sqft) 663 Btuh
Doors Type Area (sqft) HTM Load
1 Insulated-Exterior 20.0 10.2 205 Btuh
2 Insulated-Exterior 20.0 10.2 205 Btuh
Door Total 40(sqft) 409 Btuh
Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load
1 Vented Attic/Light/Shingle 0.032 30.0/0.0 605.0 1.43 867 Btuh
Ceiling Total 605(sqft) 867 Btuh
Floors Type R-Value Size HTM Load
1 Slab On Grade 0.0 605(ft-perimeter) 0.0 0 Btuh
Floor Total 605.0 (sqft) 0 Btuh
Envelope Subtotal: 2891 Btuh
Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load
Natural 0.17 10864 1 31.4 690 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 4 X 230 + 1200 2120 Btuh
Sensible Envelope Load: 5701 Btuh
Duct load Average sealed,Supply(R6.0-Condi),Retum(R6.0-Condi) (DGM of 0.000) 0 Btuh
Sensible Load All Zones 5701 Btuh
EnergyGaugee/USRCZB v5.1 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233
9/19/2017
WHOLE HOUSE TOTALS
Sensible Envelope Load All Zones 5701 Btuh
Sensible Duct Load 0 Btuh
Total Sensible Zone Loads 5701 Btuh
Sensible ventilation 0 Btuh
Blower 0 Btuh
Whole House Total sensible gain 5701 Btuh
Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 1046 Btuh
Latent ventilation gain 0 Btuh
Latent duct gain 0 Btuh
Latent occupant gain (4.0 people @ 200 Btuh per person) 800 Btuh
Latent other gain 0 Btuh
Latent total gain 1846 Btuh
TOTAL GAIN 7547 Btuh
EQUIPMENT
1. Central Unit # 24000 Btuh
*Key: Window types(Panes-Number and type of panes of glass)
(SHGC-Shading coefficient of glass as SHGC numerical value)
(U-Window U-Factor)
(InSh-Interior shading device: none(No),Blinds(B),Draperies(D)or Roller Shades(R)) hmermiM
- For Blinds:Assume medium color, half closed
For Draperies:Assume medium weave,half closed
For Roller shades:Assume translucent,half closed
(IS-Insect screen:none(N), Full(F)or Half(Y4)
(Ornt-compass orientation) MUM't
Version 8
EnergyGauge®/USRCZB v5.1 Page 2
System Sizing Calculations - Winter
Residential Load - Room by Room Component Details
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233 Building Type: User
9/19/2017
Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 41.0 F (TMY3 99%)
Component Loads for Room#1: 1st Floor
Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load
1 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh
2 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh
3 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh
Window Total 43.1(sqft) 530 Btuh
Walls Type Ornt. Ueff. R-Value Area X HTM= Load
(Cav/Sh)
1 Frame-Wood -Ext (0.077) 19.0/0.0 84 3.17 268 Btuh
3 Frame-Wood - Ext (0.077) 19.0/0.0 97 3.17 306 Btuh
Wall Total 181(sqft) 573 Btuh
Doors Type Storm Ueff. Area X HTM= Load
1 Insulated-Exterior, m (0.460) 20 18.9 377 Btuh
2 Insulated - Exterior, m (0.460) 20 18.9 377 Btuh
Door Total 40(sqft) 754Btuh
Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load
1 Vented Attic/L/Shing (0.032) 30.0/0.0 605 1.3 790 Btuh
Ceiling Total 605(sqft) 790Btuh
Floors Type Ueff. R-Value Size X HTM= Load
1 Slab On Grade (1.180) 0.0 190.0 ft(perim.) 48.4 9192 Btuh
Floor Total 605 sqft 9192 Btuh
Room Envelope Subtotal: 11839 Btuh
Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.23 6440 0.47 19.8 892 Btuh
Duct load Average sealed,Supply(R6.0-Cond.),Return(R6.0-Cond.) (DLM of 0.000) 0 Btuh
Room #1 Sensible Room Subtotal 12731 Btuh
Component Loads for Room#2: 2nd Floor
Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load
4 2, NFRC 0.30 Vinyl 0.30 N 15.5 12.3 191 Btuh
5 2, NFRC 0.30 Vinyl 0.30 N 15.5 12.3 191 Btuh
6 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh
7 2, NFRC 0.30 Vinyl 0.30 S 15.5 12.3 191 Btuh
Window Total 62.0(sqft) 763 Btuh
EnergyGauge®/USRCZB v5.1 Page 1
Manual J Winter Calculations
Residential Load - Component Details (continued)
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233 Building Type: User
9/19/2017
Walls Type Ornt. Ueff. R-Value Area X HTM= Load
(Cav/Sh)
5 Frame-Wood - Ext (0.077) 19.0/0.0 101 3.17 320 Btuh
7 Frame-Wood - Ext (0.077) 19.0/0.0 101 3.17 320 Btuh
Wall Total 202(sgft) 640 Btuh
Room Envelope Subtotal: 1403 Btuh
Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.23 4424 0.53 22.1 995 Btuh
Duct load Average sealed,Supply(R6.0-Cond.),Return(R6.0-Cond.) (DLM of 0.000) 0 Btuh
Room #2 Sensible Room Subtotal 2398 Btuh
kilHOLE HOUSE TOTALS
Subtotal Sensible Heat Loss 15129 Btuh
Totals for Heating Ventilation Sensible Heat Loss 0 Btuh
Total Heat Loss 15129 Btuh
EQUIPMENT
1. Electric Heat Pump # 24000 Btuh
Powriety
Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values)
or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults)
U-(Window U-Factor)
HTM (Manual)Heat Transfer Multiplier)
Version 8
EnergyGauge®/USRCZB v5.1 Page 2
System Sizing Calculations - Summer
Residential Load - Room by Room Component Details
Project Title:
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233
9/19/2017
Reference City: Jacksonville, FL Temperature Difference: 20.0F(TMY3 99%) Humidity difference:49gr.
Component Loads for Room#1: 1st floor
Type* Overhang Window Area(sqft) HTM Load
Window Panes SHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded
1 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 13.8 0.0 13.8 9 9 123 Btuh
2 2 NFRC 0.30,0.30 B-L No N 6.0ft 1.0ft 13.8 0.0 13.8 9 9 123 Btuh
3 2 NFRC 0.30,0.30 B-L No S 6.0ft 1.0ft 15.5 15.5 0.0 9 11 139 Btuh
Window Total 43 (sqft) 385 Btuh
Walls Type U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
1 Frame-Wood-Ext 0.08 19.0/0.0 84.4 1.7 146 Btuh
3 Frame-Wood-Ext 0.08 19.0/0.0 96.5 1.7 167 Btuh
Wall Total 181 (sqft) 313 Btuh
Doors Type Area(sqft) HTM Load
1 Insulated-Exterior 20.0 10.2 205 Btuh
2 Insulated-Exterior 20.0 10.2 205 Btuh
Door Total 40(sqft) 409 Btuh
Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load
1 Vented Attic/Light/Shingle 0.032 30.0/0.0 605.0 1.43 867 Btuh
Ceiling Total 605 (sqft) 867 Btuh
Floors Type R-Value Size HTM Load
1 Slab On Grade 0.0 605(ft-perimeter) 0.0 0 Btuh
Floor Total 605.0 (sqft) 0 Btuh
Zone Envelope Subtotal: 1974 Btuh
Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load
Natural 0.17 6440 0.47 14.8 326 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 0 X 230 + 1200 1200 Btuh
Sensible Envelope Load: 3500 Btuh
Duct load Average sealed,Supply(R6.0-Cond.),Return(R6.0-Cond.) (DGM of 0.000) 0 Btuh
Sensible Zone Load 3500 Btuh
Component Loads for Room#2:2nd Floor
Type* Overhang Window Area(sqft) HTM Load
Window Panes SHGC U InSh IS Omt Len Hgt Gross Shaded Unshaded Shaded Unshaded
4 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 15.5 0.0 15.5 9 9 139 Btuh
5 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 15.5 0.0 15.5 9 9 139 Btuh
6 2 NFRC 0.30,0.30 B-L No S 1.0ft 1.0ft 15.5 12.6 2.9 9 11 145 Btuh
7 2 NFRC 0.30,0.30 B-L No S 1.0ft 1.0ft 15.5 12.6 2.9 9 11 145 Btuh
Window Total 62 (sqft) 567 Btuh
EnergyGauge®/USRCZB v5.1 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233
9/19/2017
Walls Type U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
5 Frame-Wood-Ext 0.08 19.0/0.0 101.0 1.7 175 Btuh
7 Frame-Wood-Ext 0.08 19.0/0.0 101.0 1.7 175 Btuh
Wall Total 202 (sqft) 350 Btuh
Zone Envelope Subtotal: 917 Btuh
Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load
Natural 0.17 4424 0.53 16.6 364 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 4 X 230 + 0 920 Btuh
Sensible Envelope Load: 2201 Btuh
Duct load Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DGM of 0.000) 0 Btuh
Sensible Zone Load 2201 Btuh
EnergyGauge®/USRCZB v5.1 Page 2
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_JACKSONVILLE_INTL ARPT
160 SANDY BEACH LANE HABITAT-QUADPLEX-INSIDE-160 SB
ATLANTIC BEACH , FL 32233
9/19/2017
WHOLE HOUSE TOTALS
Sensible Envelope Load All Zones 5701 Btuh
Sensible Duct Load 0 Btuh
Total Sensible Zone Loads 5701 Btuh
Sensible ventilation 0 Btuh
Blower 0 Btuh
Whole House Total sensible gain 5701 Btuh
Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 1046 Btuh
Latent ventilation gain 0 Btuh
Latent duct gain 0 Btuh
Latent occupant gain (4.0 people @ 200 Btuh per person) 800 Btuh
Latent other gain 0 Btuh
Latent total gain 1846 Btuh
TOTAL GAIN 7547 Btuh
EQUIPMENT
1. Central Unit # 24000 Btuh
*Key: Window types(Panes-Number and type of panes of glass)
(SHGC-Shading coefficient of glass as SHGC numerical value)
(U-Window U-Factor)
(InSh-Interior shading device:none(No), Blinds(B),Draperies(D)or Roller Shades(R))
- For Blinds:Assume medium color,half closedftarrIll
For Draperies:Assume medium weave,half closed
For Roller shades:Assume translucent,half closed
(IS-Insect screen: none(N), Full(F)or Half(')) trilo r....v..-•
(Omt-compass orientation) MO_
Version 8
EnergyGauge®/USRCZB v5.1 Page 3
wrightsoft Manual S Compliance Report Job: 160 SB Lane
Date: 10-17-2017
Entire House By:
Florida Air Service & Engineering Plan: 13581
150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM
Project Information
For: Beaches Habitat
Cooling Equipment
Design Conditions
Outdoor design DB: 92.8°F Sensible gain: 16874 Btuh Entering coil DB: 76.6°F
Outdoor design WB: 77.0°F Latent gain: 3209 Btuh Entering coil WB: 63.5°F
Indoor design DB: 75.0°F Total gain: 20083 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L
Actual airflow: 800 cfm
Sensible capacity: 18688 Btuh 111%of load
Latent capacity: 3802 Btuh 118%of load
Total capacity: 22490 Btuh 112%of load SHR: 83%
Heating Equipment
Design Conditions
Outdoor design DB: 32.5°F Heat loss: 22226 Btuh Entering coil DB: 68.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L
Actual airflow: 800 cfm
Output capacity: 24000 Btuh 108%of load Capacity balance: 32 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 4.7 kW 73%of load Temp. rise: 50 °F
Meets all requirements of ACCA Manual S.
2017-Oct-17 20:16:41
wrightsoft Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1
..\Beaches Habitat\160 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE
Project SummaryJob: 160 SB Lane
-f +- wrightsoftDate: 10-17-2017
Entire House By:
Florida Air Service & Engineering Plan: 13581
150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM
Pro'ect Information
For: Beaches Habitat
Notes: 160 Sandy Beach Lane
Desi• n Information
Weather: Jacksonville/Intnl., FL, US
Winter Design Conditions Summer Design Conditions
Outside db 33 °F Outside db 93 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 18 °F
Daily range M
Relative humidity 50
Moisture difference 50 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 18522 Btuh Structure 14062 Btuh
Ducts 3704 Btuh Ducts 2812 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 22226 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 16874 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1992 Btuh
Ducts 1216 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1358 1358 Equipment latent load 3209 Btuh
Volume(ft3) 10624 10624
Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 20083 Btuh
Equiv. AVF(cfm) 80 41 Req. total capacity at 0.70 SHR 2.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HBC524A00300 Cond 25HBC524A00300
AHRI ref 9154698 Coil FX4DNF025L
AHRI ref 9154698
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 16800 Btuh
Heating output 24000 Btuh @ 47°F Latent cooling 7200 Btuh
Temperature rise 27 °F Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.036 cfm/Btuh Air flow factor 0-047 cfm/Btuh
Static pressure 0.25 in H2O Static pressure 0.25 in H2O
Space thermostat Load sensible heat ratio 0.84
Capacity balance point=32°F
Backup:
Input= 5 kW, Output= 16145 Btuh, 100 AFUE
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.1. wrightsoft 2017-Oct-17 20:16:41
/�" g Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1
..\Beaches Habitat\160 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE
4 Right-J® Worksheet Job: 160 SB Lane
Entire House Date: 10-17-2017
By:
Florida Air Service & Engineering Plan: 13581
150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM
1 Room name
2 Exposed wall House Great
230.0 ft 58.0 ft
3 Room height 8.0 ft 8.0 ft heat/cool
4 Room dimensions 16.0 x 21.0 ft
5 Room area 1328.0 ft' 336.0 ft'
I t I r r
Ty Construction U-value Or I HTMArea (ft') Load Area (ft') Load
number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh)
Heat I Cool Gross I N/P/S Heat I Cool I Gross N/P/S I Heat I Cool
6 W 12B-Osw 0.097 ne 3.64 2.70 2801 280 1019 755 0 0 0 0
. W 12E-Osw 0.068 ne 2.55 1.43 384 384 979 551 168 168 428 241
12E-Osw 0.068 se 2.55 1.43 256 206 526 296 128 78 199 112
1D-c2ow 0.570 se 21.38 18.20 29 29 630 536 29 29 630 536
11 11D0 0.390 se 14.62 11.78 20 20 298 240 20 20 298 240
W 128-0sw 0.097 sw 3.64 2.70 248 248 902 669 0 0 0 0
W 12E-Osw 0.068 sw 2.55 1.43 416 416 1061 597 168 168 428 241
12E-Osw 0.068 nw 2.55 1.43 256 220 561 316 0 0 0 0
1D-c2ow 0.570 nw 21.38 39.24 16 0 333 612 0 0 0 0
D 11D0 0.390 nw 14.62 11.78 20 20 298 240 0 0 0 0
C 168-Oad 0.408 - 15.30 21.91 68 68 1040 1490 0 0 0 0
C 16B-30ad 0.032 - 1.20 1.72 32 32 38 55 0 0 0 0
C 168-7ad 0.112 - 4.20 6.01 668 668 2806 4018 0 0 0 0
F 22A-tol 0.989 - 37.09 0.00 768 128 4747 0 336 58 2151 0
1 6 1 c)AED excursion 20117
Envelope loss/gain 1 1 152391 105751 41351 13541
12 a) Infiltration 3283 796 828 201
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 3 690 0 0
Appliances/other 2000 0
Subtotal(lines 6 to 13) 18522 14062 4963 1555
Less external load 0 0 0 0
Less transfer
Redistribution 0 0 0 0
0 0 123 25
14 Subtotal 18522 14062 5086 1580
15 Duct loads 20% 20% 3704 2812 20% 20% 1017 316
Air
Total roomrequired load(cfm)
I I I 222268001 16874800 f
1 I I 6103 I 1896
220 90
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
44-
' wright�oft Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-1720:16:41
"r
Page 1
...\Beaches Habitat Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE
4 wrightsoft Right-J® Worksheet Job: 160 SB Lane
Entire House Date: 10-17-2017
By:
Florida Air Service & Engineering Plan: 13581
150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM
1 Room name Mech Kitchen
2 Exposed wall 6.0 ft 14.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 4.0 x 6.0 ft 1.0 x 136.0 ft
5 Room area 24.0 ft' 136.0 ft'
I r i r t
Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') Load
number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
1 Neat I Cool Gross I N/P/S Heat Cool Gross N/P/S Heat I Cool
6 W 12B-Osw 0.097 ne 3.64 2.70 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 80 80 204 115
12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0
1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0
11 11D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0
W 12B-Osw 0.097 sw 3.64 2.70 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 sw 2.55 1.43 48 48 122 69 32 32 82 46
11 12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0
1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0
11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0
C 16B-Oad 0.408 - 15.30 21.91 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0
C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0
F 22A-tol 0.989 - 37.09 0.00 24 6 223 0 136 14 519 0
6 c)AED excursion I I I -11
68
I I I 23
Envelope loss/gain 345+1 68 I{ 1 805 137
12 a) Infiltration 86 21 200 48
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 2000
Subtotal(lines 6 to 13) 431 89 1005 2186
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution -431 -89 1078 613
14 Subtotal 0 0 2083 2799
15 Duct loads 20% 20% 0 0 20% 20% 417 560
Total
requirroomed load( )
I I I I OI OI I 24991 33591
Air cfm0 0 90l 159
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-44- wrightsoft 2017-Oct-17 20:16:41
Right-Suite®Universal 2017 17.0.29 RSU09479 Page 2
..\Beaches Habitat\160 Sandy Beach Lane113581.rup Calc=MJ8 Front Door faces:SE
4 wri
4 wrightsoft Right-J® Worksheet Job: 160 SB Lane
Entire House Date: 10-17-2017
By:
Florida Air Service & Engineering Plan: 13581
150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM
1 Room name Hall Bed 3
2 Exposed wall 21.0 ft 37.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 1.0 x 100.0 ft 1.0 x 171.0 ft
5 Room area 100.0 ft' 171.0 ft'
I I I t t
TyConstruction U-value Or HTM Area ft') Load Area (ft') Load
number (Btuh/ft'-'F (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat I Cool Gross NIP/S Heat I Cool I Gross I N/P/S Heat Cool
6 W 12B-Osw 0.097 ne 3.64 2.70 0 0 0 0 72 72 262 194
. W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 0 0 0 0
12E-Osw 0.068 se 2.55 1.43 0 0 0 0 128 128 326 184
1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0
11 11 11 D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0
W 12B-Osw 0.097 sw 3.64 2.70 0 0 0 0 88 88 320 237
W 12E-Osw 0.068 sw 2.55 1.43 136 136 347 195 8 8 20 11
12E-Osw 0.068 nw 2,55 1.43 32 12 30 17 0 0 0 0
1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0
11D0 0.390 nw 14.62 11.78 20 20 298 240 0 0 0 0
C 16B-Dad 0.408 - 15.30 21.91 68 68 1040 1490 0 0 0 0
C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0
C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 171 171 718 1028
F 22A-tpl 0.989 - 37.09 0.00 100 21 779 0 0 0 0 0
6 c)AED excursion -21 -21
Envelope loss/gain 1 24941 1920 16471 1634
12 a) Infiltration 300 73 528 128
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 2794 1993 2175 1992
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution -2794 -1993 334 317
14 Subtotal 0 0 2509 2309
15 Duct loads 20% 20% 0 0 20% 20% 502 462
ToAirtalrequireroomd load(cfm)
I I I OI OI I 3011 2771
0 0 ! 108 131
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.:-.-. �' wrightsoft 2017-Oct-17 20:16:41
,04_,. .':"6., Right-Suite®U niversal 2017 17.0.29 RSU09479 Page4
...\Beaches Habitat\160 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE
''f'- wrightsoft Right-J® Worksheet Job: 160 SB Lane
Entire House Date: 10-17-2017
Florida Air Service & Engineering Plan: 13581
150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM
1 Room name Bath 2
Bed 2
2 Exposed wall 9.0 ft 38.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 7.0 x 9.0 ft 16.0 x 11.0 ft
5 Room area 63.0 ft' 176.0 ft'
t I r i r I
Ty Construction U-value Or I HTMI Area (ft') Load Area (ft') Load
number (Btuh/ft'-°F
(Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
IHeat I Cool I Gross N/P/S Heat I Cool I Gross I N/P/S Heat Cool
6 W 12B-Osw 0.097 ne 3.64 2.70 72 72 262 194 88 88 320 237
W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 0 0 0 0
12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0
1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0
1 1 11 D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0
W 12B-Osw 0.097 sw 3.64 2.70 0 0 0 0 64 64 233 173
W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 24 24 61 34
12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 128 128 326 184
1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0
11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0
C 16B-Oad 0.408 - 15.30 21.91 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0
C 16B-7ad 0.112 - 4.20 6.01 63 63 265 379 176 176 739 1059
F 22A-til 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0
6 1 c)AED excursion 1 { 1 5271 5671 16801 1665-221
Envelope loss/gain
12 a) Infiltration 128 31 542 132
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 655 598 2222 2026
Less external load 0 0 0 0
Less transfer
Redistribution 0 0 0 0
483 458 594 564
14 Subtotal 1138 1056 2816 2590
15 Duct loads 20% 20% 228 211 20% 20% 563 518
Air
Totalroomerequiredloa( dcfm)
11 I I I 13651 12671 I I 33791 31081
49 60 122 147
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-44" wri9Mtsoft 2017-Oct-17 20:16:41
A�7 Right-Suite®Universal 2017 17.0.29 RSU09479 Page 5
...)Beaches Habitat\160 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE
4 wrightsoft Right-J® Worksheet Job: 160 SB Lane
Entire House Date: 10-17-2017
By:
Florida Air Service & Engineering Plan: 13581
150 Hilden Road 308.Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM
1 Room name Loft
2 Exposed wall 18.0 ft
3 Room height 6.0 ft heat/cool
4 Room dimensions 1.0 x 150.0 ft
5 Room area 150.0 ft'
i I i I I r
Ty Construction U-value OrHTM Area (ft') Load Area Load
number (Btuh/ft'-°F I (Btuh/ft') I or perimeter (ft) (Btuh) I or perimeter 1I {
Heat I Cool I Gross I N/P/S Heat I Cool I Gross N/P/S 1 Heat I Cool
6 W 12B-Osw 0.097 ne 3.64 2.70 48 48 175 1291
. W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0
12E-Osw 0.068 se 2.55 1.43 0 0 0 0
1D-c2ow 0.570 se 21.38 18.20 0 0 0 0
11 11D0 0.390 se 14.62 11.78 0 0 0 0
W 12B-Osw 0.097 sw 3.64 2.70 96 96 349 259
W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0
12E-Osw 0.068 nw 2.55 1.43 0 0 0 0
1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0
D 11D0 0.390 nw 14.62 11.78 0 0 0 0
C 16B-Oad 0.408 - 15.30 21.91 0 0 0 0
C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0
C 16B-7ad 0.112 - 4.20 6.01 150 150 630 902
F 22A-tol 0.989 - 37.09 0.00 0 0 0 0
1 6 1 c)AED excursion -14
Envelope loss/gain I 1154 12761 I 1
12 a) Infiltration 257 62
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 1411 1338
Less external load 0 0
Less transfer 0 0
Redistribution -1411 -1338
14 Subtotal 0 0
15 Duct loads 20% 20% 0 0
Totalrequirroomed load(cfm)
I I I 001
01 Air
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
_.1. wrightsoft 2017-Oct-17 20:16:41
PRight-Suite®Universal 2017 17.0.29 RSU09479 Page 6
...\Beaches Habitat\160 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE
��_
Air' 1st Floor
Bed 1
11.0411 171 cfm
Hall
60 crmtf
6 "
4"
Sup Riser
10 "
14 "
Kit her
W•A
M ► 800 cfm �- 6
10 " 159 cfm
•
110c'm
6 "
Grea
110cm
Job#: 160 SB Lane Florida Air Service & Engineering Scale: 1 :71
Performed for:
Page 1
Beaches Habitat
150 Hilden Road 308 Rig hi-Suite®Un iversa 12017
Ponte Vedra,Fl 32081 17.0.29 RSU09479
Phone:904-823-9696 2017-Oct-17 20:16:54
VWWV.NORTHFLORIDAAIR.COM ...t\160 Sandy Beach Lane\13581.rup
N
2nd Floor
Bed 2
6 "
Sup Ri e• ... 147 cfm
.�. d
�12 x 10
4 "
oft
6 "
•
6Bafhl
12 x 10
...
131 cfm
Bed
1 ..
Job#: 160 SB Lane Florida Air Service & Engineering Scale: 1 : 71
Performed for: Page 2
Beaches Habitat 150 Hilden Road 308
Rig ht-Suite®Un iversa 12017
Ponte Vectra,Fl 32081 17.0.29 RSU09479
Phone:904-823-9696 2017-Oct-17 20:16:54
WWW.NORTHFLORIDAAIR.COM ...t\160 Sandy Beach Lane\13581.rup
Duct System Summary Job: 160 SB Lane
wrightsoft Date: 10-17-2017
Entire House By:
Florida Air Service & Engineering Plan: 13581
150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM
Project Information
For: Beaches Habitat
Heating Cooling
External static pressure 0.25 in H2O 0.25 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.25 in H2O 0.25 in H2O
Supply/return available pressure 0.125/0.125 in H2O 0.125/0.125 in H2O
Lowest friction rate 0.100 in/100ft 0.100 in/100ft
Actual air flow 800 cfm 800 cfm
Total effective length (TEL) 130 ft
Supply Branch Detail Table
I
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk
Bath h 1660 60 41 0.100 4.0 Ox 0 VIFx 16.0 90.0 st2
Bath 2 c 1267 49 60 0.100 4.0 Ox 0 VIFx 16.2 110.0 st1
Bed 1 c 3607 151 171 0.100 6.0 Ox 0 VIFx 22.0 90.0 st2
Bed 2 c 3108 122 147 0.100 6.0 Ox 0 VIFx 9.1 110.0 st1
Bed 3 c 2771 108 131 0.100 6.0 0x 0 VIFx 20.4 110.0 st1
Great h 3052 110 45 0.100 6.0 Ox 0 VIFx 14.9 90.0 st2
Great-A h 3052 110 45 0.100 6.0 Ox 0 VIFx 26.4 90.0 st2
Kitchen c 3359 90 159 0.100 6.0 0x 0 VIFx 8.8 90.0 st2
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st1 Peak AVF 279 339 0.100 621 10.0 0 x 0 VinIFIx
st2 Peak AVF 521 461 0.100 487 14.0 0 x 0 VinIFIx
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk
rb1 Ox 0 800 800 0 0.080 573 16.0 Ox 0 VIFx
Bold/italic values have been manually overridden
t wrightsoft 2017-Oct-1720:16:41
�. 9 Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1
...\Beaches Habitat1160 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE