Loading...
168 SANDY BEACH LN - NEW HOME PERMIT /PP'"_• - CITY OF ATLANTIC BEACH s> 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0236 Description: new attached single-family Estimated Value: 141800.5 Issue Date: 11/15/2017 Expiration Date: 5/14/2018 PROPERTY ADDRESS: Address: 168 SANDY BEACH LN RE Number: 173414 0175 PROPERTY OWNER: Name: BEACHES HABITAT FOR HUMANITY INC Address: 797 MAYPORT RD ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: 201 MAYPORT CONSTRUCTION MANAGEMENT Address: 2768 STATE RD A1A#701 ATLANTIC BEACH, FL 32233 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. ,S _.:�.b. City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 1.5 aw. 800 Seminole Road [,���_ �� �,, Atlantic Beach, Florida 32233-5445 I�ct Phone(904)247-5826 • Fax(904)247-5845 •",. .._„011 9r E-mail: building-dept@coab.us Date routed: ID Ic"S(iq City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l (6 5cinCiy &AO\ Ln - Department review required Yes o (uildincq-N Applicant: ao L M 0,Nil poi -• CO/1Sk(1mA►'3/ <Plann nI g&Zoning JJ Tree Administrator Project: nQ,� CA, V�O� 611. t-.41-m, 19 Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: l%proved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDIN PLANNING &ZONING �� 7'.02017Reviewed by: Date: TREE ADMIN. Second Review: Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: _ Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 •5 �,,t_or, City of Atlantic Beach APPLICATION NUMBER rj r s, Building Department (To be assigned by the Building Department.) 800 Seminole Road f Cl / -0 Atlantic Beach, Florida 32233-5445 ►w l CI (C) Phone(904)247-5826 • Fax(904)247-5845 '"%rJni ((q- Citybuilding-dept@coab.us Date routed: 10 dS l Iq- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: L 4(6 (Sandy eoutil Ln - Department review required Yes No Ian r ,, Buil in Applicant: �`° M out p0! k Cons c,��3 _ fanning &Zoning Tree Administrator Project: (\t-i-} C,1 S\nl.�-.'Q m, tL( Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING PUNNING &ZONING Reviewed by/ Date: (�^��/�� TREE ADMIN. Second Review: Approved as revised. ❑Denied. 'Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I 'Approved as revised. nDenied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ,;/Ld- . City of Atlantic Beach APPLICATION NUMBER �s Building Department (To be assigned by the Building Department.) 800 Seminole Road rn / _c f�_ ;, Atlantic Beach, Florida 32233-5445 ►LG-�l Phone (904)247-5826 • Fax(904) 247-584 ; r �L ;319%' E-mail: building-dept@coab.us l�J(L, 017 Date routed: 10 I3"S fig- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l 4 (6 SCLACI.y 6/.-4.01 Lf l - Department review required Yes No Builm Applicant: ao ( M 0,( pO f k CONS c,�►�3 eiann nig&Zoning _ �� �" f Tree Administrator Project: IN LW a i WI S1 fli t---"Q.M i I I Publ c W rks Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By _ Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 1V(Approved. ❑Denied. nNot applicable (Circle one.) Comments: BUILDING r / PLANNING &ZONING Reviewed by✓ Date:/e---7/17 TREE ADMIN. Second Review: A roved as revised. Denied. ❑ pp ❑ ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: (Approved as revised. Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 rCity of Atlantic Beach APPLICATION NUMBER (111 i1 Building Department (To be assigned by the BuildingDepartment.) 800 Seminole Road C���r Atlantic Beach, Florida 32233-5445qM 1� -'Phone(904)247-5826 • Fax(904) 247-5845 OCT 2fi2017 ;119E-mail: building-dept@coab.us Date routed: 10 la-,S"II"4 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: [ k (6 <Sa.nAy etettUtil LA - Department review required Yes No Buildin Applicant: ao ( l_1�n`mkt pO f k r WAS LVi fanning &Zoning—) J Tree Administrator Project: nQ.,� tit, SI1_I --4.pat 1L1 Public Works Public Utilities Public Safety Fire Services Review fee $ D Dept Signature , .ti. , Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APP (CATION STATUS Reviewing Department First Review: Approved. ❑Denied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: ( — Date:l/ i 1 1 TREE ADMIN. Second Review: Approved as revised. ❑Denied. I (Not applicable PU=LeWORKS)„Comments: /UBLIC UTILITIES // — 2— /7 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I 'Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH OFFICE COPY 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: # 168 Sandy Beach Lane, COAB, 32233 Permit Number: qkS 11_0 3-4, Legal Description: 38-2S29E-7.41B De Castro Y Ferrr Grant PT RECD O/R 16531-2248 Parcel#Blk: 1 Lot: 4 Floor Area of Sq.Ft. Sq.Ft Valuation of Work $110,000 Proposed Work heated/cooled 1170 non-heated/cooled 200 Class of Work(circle one): New (X) Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s) (circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No(X) N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: Construct attached two story Quad single family homes Property Owner Information: Name: Beaches Habitat for Humanity Address: 797 Mayport Rd City Atlantic Beach State FL Zip 32233 Phone#904-241-1202 E-Mail or Fax#(Optional)#904-241-4310, rpeterson@beacheshabitat.org Contractor Information: Company Name:201 Mayport Construction Management, LLC Qualifying Agent: Robert Peterson Address: 2768 State Rd.AlA#701 City Atlantic Beach State FL Zip 32233 Office Phone 904-595-5798 Job Site/Contact Number 904-334-1202 Fax# State Certification/Registration#CGC1506666 Architect Name &Phone# Ju\,CATh- Qve.kM qpy- 1O4- 662% Engineer's Name&Phone# ` c ,on c e,\ C.,l y r,h 1telcl N c104- In 80- (o 219 Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of six 6)months at any time afterwork is commenced. I understand that separate permits must be secured for ElectricalpWork,Plumbing,Signs, Wells,Pools, Furnaces , Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined thisplication and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein ornot. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other fe ral,state,or local law regulating construction or the performance of construction. Signature of Owner Signature of Contractor Print Name Print Name Le,* yrs Sworn to and subscribed before me Sworn to and subscribed before me this pit- Day of 'L _Lc c ,20 I this /yI' Day of cep/---&-,h-e._r ,20 / Notary Publ. Notary Public 1ii�Y�►i%s'•., LE MURRAY , o KYLE MURRAY sed 01.26.10 � ;a¢ � os Notary Public•State of Florida r,, ,,, RRPP "_ ('c,"-- Notary Public•State of Florl�'e ►. Commission#FF 941841 =: My Comm.Expires Apr 2,2020 ' "i 1 ',, Bonded through National Notary Assn. ( ,� � My comCommi.Expionires Apr941t,2020 � Bonded throssw N#ationFFal Notary841 Assn. , 201_ Mr. Kayle Moore Public Utilities Director City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 Mr. Moore I have submitted a building permit application for the Quad"B"" located at: #156,160,164,168 Sandy Beach Lane, COAB (Blk. # 1, Lots #4,5,6,7) Beaches Habitat will not be installing a fire sprinkler in this structure. In addition, according to our HOA agreement we will be installing an irrigation system for the common areas. Please give me a call (904-241-1222, or 334-1202) if you require any additional information. Sincerely, R rt _ Construction Director City of Atlantic Beach PUBLIC UTILITIES DEPARTMENT ;. 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date /1 - Z — 17 Project Address /40 g 5---r9"//(0y E?*v/ 6471 E-- Number of Units / Commercial Residential I/ Multi-Family 3 New Water Tap(s) & Meter(s) Meter Size(s) �-{ New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application# a-75 (7 — 0 2-3(47 Mum // FAM Water System Development Charge $ !201 6(91/1 Sewer System Development Charge $ C)f . &Q I. Water Meter Only $ / 8 S , (.Y Reclaim Meter Only $ Water Meter Tap $ Sewer Tap $ Cross Connection $ <50 , vo Other $ TOTAL $ 235-, C)a (Notes) APPROVED Kayle Moore, P.E. Date t(t( (3 /c 7 Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED Permit Attachment—__of Permit# ---_ for .__issued ,20 Atlantic Beach,FL 32233 Owner's Name• g,tacwes 1 4 R.E. #: • property Address: Subdivision: * /y ____________Lot#/Block#:�}� REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PE by Atlantic Beach, Florida, a m �T,issued on this Florida, municipal corporation organized and existingday of t State20 of hereinafter referred to as "CITY" and r•. under the laws the Florida,hereinafter referred to as "USER". s. r of Atlantic Beach, Fo , WETNESSETH: Thaty grant the the CITY does hereby enter uponUSER permission on a revocable basis as described herein the right to the property of the City of Atlantic Beach for the Purpose as described in the City of Atlantic Beach Right-of-Way/Easement Permit numbers noted above(copies attached). This work is generally described as: ll r 1 44hUt.wek. Ora` R. O. 4). Any facility maintained, repaired, erected subject o relocation or removal d,n erected, and/or installed in the exercise of the privilege given bythirty(30)days notice bygranted ER remains e certified •mail, return CITY to the USER, said notice to USER shall be '1 1 l 4- f _ receipt requested, to the folio The wing address: depositing of said notice of cancellation in cancellation and the burden upon ato keepthe United States the CITY informed of USER'S proper l eddies the notice of The USER se hall promptly make any exercise of th pm herein and all necessary repairs to any facility granted and shall at all times erected or maintained in the maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's enter upon above-described roe approved representative or other franchised utility to any and all the above-described e-d necessarily property rty of the CITY, the USER shall replace at the USER'S sole expense, addingnyato of the material send ril diisplities ced the CITY the or action of maintaining, repairing, operating, replacing, or The facilities allowed bythe utility provider. Land Development permit shall meet the current requirements of the City Code, Building Codes, P ent Code, and all other land use and code requirements of the CITY,including City Code Section 19-7(h)which states"Driveways that cross sidewalks: City with other materials, but must be replaced with smooth concrete left natural existing and ado sidewalks may not be replaced adjoining sidewalks. heal in color so that it matches the Page 1 of 2 I The USER, prior to making any changes from thea ritten approval from the Cityoof Atlantic Beach,capproved plans and/or method, discretion of the CITY, be requested to submitbas-built 1]t drawings Department, for said change. The USER shall,at the after the day of completion. This Permit shall insure to the benefit of, and be bindingu tvmg the change within thirty (30) days assigns. upon, the USER and their respective successors and • USER shall meet the terms and conditions of this permit and to all of the and/or specifications,the to sinclude and conditions locate r ublic rind/or specs and other public land. applicable State and CITY laws requirements and use limitations/requirements be saved harmless by the USER from USER further agrees that the CITY and its officers and employees shall any of the work herein under the terms of this e y the USER. pent and that all of said liabilities are hereby assumed b DATED and SIGNED this 11� day of ,20 1 ,,,:,.,,,, ►rKYLE MURRAY $y, `' _ • .v1,12-4;\ Notary Public-State of Florida ., �✓ . 74.,3-,„2,..11,-, ▪. ,�� Commission #FF 941841 Property Owne'! -,„ � ?.� My Comm.Expires Apr 2,2020 (to be signed Bonded through National Notary Assn gn in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL / .....-2...---....... On thisai day of (� and for said Count �' '7p y and State, ersonally appeared before me, a Notary Public in and who executed the foregoing Atlantic Beach, Florida, o the property owner of g g instrument; who acknowledged to me that he mear hebe texecu ed e sameaeibed in and voluntarily and for the uses and purposes therein mentioned. the freely Notary Public in for said County and State CITY OF ATLANTIC BEACH, FLORIDA a municipal corporation: ' Approved: /d • P% Pub c ��orks Director %fear For Permits vvhe '�� city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2 I - CITY OF ATLANTIC BEACH %7' �' CONSTRUCTION ' --_� � PERMIT �`-,--%.---...,: Aoo Seminole Road WITHIN CITY RIGHTS OF WAY ���� ' AND EASEMENTS )antic Beach,Florida 32233-5445 PLEASE SUBMICOMPLETE SETS OF P 904-247-5800 PLANS WITH APPLICATION. Fax 904-247-5845 Date Job Address _ to PERMIT# Permitee: . �. t;.,,�5 �fi rs, COPOP, Phone ISSUED BY THE CITY Mo Permittee Address: Z 1 Tele a.. . '94F # F oy - 3 3 Requesting Permission to Construct: 2_1_33 Location: �'— '"` d ,..f u�,�,,,, (Reference to Cross-Street) R.O' . 1. that Applicant declares prior to filin both canalg and re prio and the ccisrates ppli cation ons heare sh has asnertained. the location of all existing utilities, A Letter of Notification was mailed to the followingown on the sketches. Jacksonville Electric Authority Utilities/Municipalities: Bell South Telephone Company Ferrell Gas Yes( ) No ( ) Date: Comcast Yes( ) No ( ) Date: Yes( ) No ( ) Date: 2. Whenever necessaery Yes ( ) No alteration or ecessrelocation all, or construction, re ( ) Date: Works, anypair, improvement, or all of ofaidany portion of said street or easement as determined by poles, safe and efficient operation, k shall be immediately ly removedres, from said street the Directorsa h razed wires, pipes, cables or other facilities reqheruired by the Directoreimof Public Works, and appurtenances authorized authorized. and at the a or easement or reset or relocated s 3. All work shall meet City expense of the Permittee unless reimbursement as work of Atlantic Beach or Florida under the supervisionDepartment of Transportation Standards and be Superintendent) located at � °f t+�' 4. All materials and e > � 5. All city equipment shall berms�� �I '� � (Contractor's ty eropertn shall pe enhal to its original to inspection afar asTelephoneWorks#: Project and the ryby the Director of Public or his designee. iia ty. 6 manner satisfactory be restored to the oi A sketch of plans of this installation practical, in keeping part P 9 with city specifications permitscoveringndetails showing , as well as, a copy 7. part of this Way. a to al iucludns d with ta us ofr a recentno This permittee shall commence actual this histructio increase in im,ervious area on ow survey shall be )lection. made a more thanr60 days from date of the lotor ithe lf Public Works to permit approval, n ►n good faith with make sure no changes then permittee days. If the the 8. 9 have occurred in the area that would affect the beginning date is It is understood and agreed that the and City's right, title and interest in the land rights bea entered upon t review the permit with the Director of of privileges o herein set out are grantedoonly to the extent of the assume all risk of and indemnify, permitted construction. agatimes, any andeall isks, damage, fY, defend, p and used s the holder,of, and the Holder will, at all exercises by and save harmless the the holder of the aforesaid rights and privileges. lege5nses �sing in any 9. The D. ector of Public Works shall be City of Atlantic Beach from and immedi_tely upon completion. manner of the exercise or attempted notified twenty-four (24) hours OWNER prior to starting work and again „Van''• a g ilk o` `e'•, KYLE MURRAY Signed: r ,•. Notaryp Before �''" n .. k-State of nor,-, State Of Florida,has personal) a Date:�'20 i, �„ C°m ansion#FF 9418 day of ,� �•' Notary Public at Large,State of Florida,County the County of Duv I, ,,,.a rf °n Comm.Expires Apr 2, 2 My commission expires: Bonded through National Nora , ty of Duval. Personally Known: Produced Identification: OFFICE COPY • DO 1WMT BELOW- OFFICE USE ONLYAppliea e Co es:2010 FLORIDA BUILDING CODE Review Result circle one : Approved Disapproved , . -Approved,w/ Conditions Review Initials/Date: Development Size Habitable Space /170 T-F. Non-HabitableS 2 —CLQ te' rapervious area liscellaneous Information Iccupancy Group 02-3 vpe of Construction V r3 ember of Stories 2. Hing District .0 2-G- x. Occupancy Load Sprinklers Required )d Zone titions/Comments: PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA _ OFFICE COPY Project Name: OceanGate: Quad "B" Permit# R S �7 az? 3 Project Address: #156,160,164,168 Sandy Beach Lane, COAB, 32233 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Steel Door FL4904 2. Sliding 3. Sectional 4. Roll up Clopay Garage Door- HDG FL5684.10 5. Automatic 6. Other B. WINDOWS 1. Single hung Atrium Single Hung Window FL11834.10 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11.. Dual action 12.. Other PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA C. PANEL WALL 1. Siding James Hardie Cemplank siding FL13192.1 2. Soffits Crane Vinyl Soffit FL2495-R1 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco Acrocrete Synthetic finish coat 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles GAF 30 yr architectural FL10124 2. Underlayments RhinoRoof Syn. Underlayment FL15216 3. Roofing fasteners 4. Nonstructural metal roof Millenia Metals Form rolled metal FL5211.2 R4 5. Built-up roofing 6. Modified bitumen Certainteed Flintlastic SA FL2533 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coasts 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other E. SHUTTERS 1. Accordion Shutter Shield Accordion FL9569.1 2. Bahama 3. Storm panels Madden Mfg. Storm Panels FL5329.1 4. Colonial _ 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor Simpson Strong- H16S FL1423.6 Tie MTS 12 FL474.253 2. Truss plates MiTek Industries Truss Plates FL2197 3. Engineered lumber Tus-Joist- Engineered Lumber FL1630 Weyerhauser 4. Railing _ 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall cam„ PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturer,product description and State approval number for the products used on this project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above, on the job site available to the inspector. The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be inspected, they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to include each new product in the categories listed above and will be highlighted to indicate the new products and required information. Authorized Project Agent: Robert Peterson; Director of Construction (Contractor or Design Professional) (Print Name) Company Name: Beaches Habitat for Humanity Mailing Address: 797 Mavport Road PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA City: Atlantic Beach State: FL Zip Code: 32233 Telephone Number: ( 904) 241-1222 Fax Number: (904 ) 241-4310 Cell Phone Number: ( 904) 334-1202 E-mail Address: rpetersonc beacheshabitat.org FORM R405-2014 OFFICE COPY RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page) and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: O Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge®-USRCZB v5.1 9/19/2017 10:18:38 AM Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-QUADPLEX-OUTSIDE-D168 Builder Name: BEACHES HABITAT Street: 168 SANDY BEACH LANE Permit Office: DUVAL COUNTY City, State.Zip: ATLANTIC BEACH , FL, 32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL, Jacksonville County:: DUVAL(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types 1637.3 sqft.)( q ) Insulation Area 2. Single family or multiple family Multi-family a. Frame-Wood, Exterior R=19.0 1138.70 ft2 3. Number of units, if multiple family 1 b. Frame-Wood,Common R=19.0 498.67 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (605.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area above grade(ft2) 1170 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 7. Windows(130.0 sqft.) Description Area 11. Ducts R ft2 a. Sup: 1st Floor, Ret: 1st Floor,AH:Attic 6 165 a. U-Factor: Dbl, U=0.30 130.00 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 22.7 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 23.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems 8. Floor Types (605.0 sqft.) Insulation Area a. Electric Cap:40 gallons a. Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 EF: 0.920 b.N/A b. Conservation features R= ft2 c.N/A R= ft2 None 15. Credits Pstat Glass/Floor Area: 0.111 Total Proposed Modified Loads: 29.38 PASS Total Baseline Loads: 33.09 I hereby certify that the plans and specifications covered by , :-`i'"'� Review of the plans and i-,..cHE sr this calculation are in compliance with the Florida Energy specifications covered by this ;, 'Ov: . ....,A!4". ., Code. calculation indicates compliance •;...�'',.~ s ifF •'r'••' A. WILKERSON with the Florida Energyps ti PREPARED BY: Code. I'kri,r"K'ivsi, ;;,a` p' Before construction is completed • rat _ DATE: q./19/2017 this building will be inspected for C: , 6 ;ad s compliance with Section 553.908 ? ,, a, , • ..* c I hereby certify tha his building, as designed, is in compliance Florida Statutes. is r;• ��, with the Florida Ener Cod • ... •.COD5`�I. OWNER/AGENT: Mi ,/'�'1 DATE: (::" N-T.----/ "�•-7•�.••�••"' BUILDING OFFICIAL: , ,�,/ ' DATE: //- 7"-c70/7 7 _ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 3.0 ACH50 (R402.4.1.2). 9/19/2017 10:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: HABITAT-QUADPLEX-OUTSI Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1170 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 270 Street: 168 SANDY BEACH LA Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 1170 9360 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 1st Floor 565 4520 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 605 4840 No 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 0 605 ft' -__- 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 638 ft' 100 ft' Medium 0.85 No 0.9 No 0 18.4 V ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 605 ft' N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 Batt 605 ft' 0 Wood 9/19/2017 10:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it Ornt To Wall Type Space P-Value Ft In Ft In Area R-Valva Frartinn Ahcnr C-Iraria0A _ 1 N=>W Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 2 E=>N Exterior Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 3 S=>E Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 _ 4 W=>S Neighbor Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 _ 5 N=>W Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 6 E=>N Exterior Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 7 S=>E Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 _ 8 W=>S Neighbor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated 1st Floor Metal .46 3 6 8 20 ft2 2 S=>E Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 6 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 7 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000152 468 25.69 48.32 .1446 3 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 23.5 kBtu/hr 1 sys#1 9/19/2017 10:18 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 3 of 4 . FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 22.7 kBtu/hr 681 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply-- --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [X]Jan rX]Feb [X]Mar [X]Apr X]May [X]Jun ?)((1 Jul [X]Aug [X]Sep [X]Oct [X]Nov X]Dec Heating X Jan X Feb X Mar X Apr X Ma X Jun Jul X Au X Se X Oct X Nov X Dec Venting X Jan X Feb Mar X Apr X MayX Jun X Jul X Aug X SepX Oct ki Nov Xi Dec Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 9/19/2017 10:18 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4 / • FORM R405-2014 / ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index,the more efficient the home. 168 SANDY BEACH LANE, ATLANTIC BEACH , FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame Wood,Exterior R=19.0 1138.70 ft2 b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 605.00 ft2 6. Conditioned floor area(ft2) 1170 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 2 a. U-Factor: Dbl,U=0.30 130.00 ft2 11.Ducts R ft a.Sup: 1st Floor,Ret:1st Floor,AH:Attic 6 165 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 22.7 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 23.5 HSPF:8.50 Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft2 a.Electric EF:0.92 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building :••••;•KE ST••••:. Construction through the above energy saving features which will be installed (or exceeded) ..: of .t...• ,..ATo in this home before final inspection. Otherwise, a new EPL Display Card will be completed k3... .'>' `,:;,�.. +' based on installed Code compliant features. m,„ , ▪ -• ;*•4'.�o rY ver:e Builder Signature: ,/ ._ All „-1_ - Date: 9/• -VI7 `:�'\ N. , �----n-- 00 .Address of New Home: 6 �: , j cs, City/FL Zip: C"D-'11, .. -7 C3• CI J *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/19/2017 10:19 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 168 SANDY BEACH LANE Permit Number: ATLANTIC BEACH , FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. 0 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. 0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. ▪ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems, if installed at the time of the test,shall be turned off; and 6.Supply and return registers, if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMANVDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. 0 R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. o R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost. prevent supplemental heat operation when the heat pump compressor can meet the heating load. o R403.2.2 Sealing(Mandatory)All ducts, air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g), or(i), Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa)across the entire system. including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa)across the system, including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 9/19/2017 10:19 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. O R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. O R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1. Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 9/19/2017 10:19 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and 0404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools, inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2, Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. 0 RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights 0 R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. 0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 9/19/2017 10:19 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-QUADPLEX-OUTSIDE-D168 Builder Name: BEACHES HABITAT Street: 168 SANDY BEACH LANE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight. IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 9/19/2017 10:19 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 • FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: HABITAT-QUADPLEX-OUTSIDE-D168 Builder Name: BEACHES HABITAT Street: 168 SANDY BEACH LANE Permit Office: DUVAL COUNTY City, State,Zip: ATLANTIC BEACH , FL, 32233 Permit Number: Design Location: FL, Jacksonville Jurisdiction: 261300 Cond. Floor Area:: 1170 sq.ft. Cond.Volume: 9360 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: CFM(50): C: n: R: ELA: Single or Multi Point Test Data HOUSE PRESSURE FLOW: EgLA. 1 Pa cfm ACH: 2 Pa cfm SLA: • 3 Pa cfm ACH(50) * : 4 Pa cfm * For prescriptive projects, tested leakage must be 5 Pa cfm <=7 ACH(50). For performance projects, tested 6 Pa cfm leakage must be <= the ACH(50) shown on Form R405-2014 for this project. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures: 3. Interior doors, if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed: 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing shall be conducted by either r r I hereby certify that the above envelope leakage individuals as defined in Section 04Zx _ ATS"••:4 performance results demonstrate compliance ,553.993(5) or(7), Florida Statutes or c�~ %, is• '=,�'� with Florida Energy-Eode requirements in • individuals licensed as set forth in ;i ; ;lr t ;, " p•.. accordance with-Section R402.4.1.2. �{ Section 489.105(3)(f), (g), or (i) or an t approved third party. A written report of the results of the test shall be signed .*,..*a. . • r SIGN URE: bythe third partyconductingthe test r may. • Op WE �c •• and provided to the code official. PRI TED NAME: `"'••••�'^ • .!P. �� DA E: BUILDING OFFICIAL: in?"- DATE: /- 7 -2c/7 9/19/2017 10:20 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 Residential System Sizing Calculation Summary Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 9/19/2017 Location for weather data: Jacksonville, FL -Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidity data: Interior RH (50%) Outdoor wet bulb (77F) Humidity difference(49qr.) Winter design temperature(TMY3 99%) 29 F Summer design temperature(TMY3 99%) 95 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 41 F Summer temperature difference 20 F Total heating load calculation 17030 Btuh Total cooling load calculation 10364 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 138.0 23500 Sensible (SHR =0.75) 196.5 17025 Heat Pump +Auxiliary(0.0kW) 138.0 23500 Latent 333.7 5675 Total (Electric Heat Pump) 219.0 22700 WINTER CALCULATIONS Winter Heating Load (for 1170 sqft) Load component Load WaHIs(18.0%) Window total 130 sqft 1599 Btuh Wall total 969 sqft 3069 Btuh ceninos(4.6%) Door total 40 sqft 754 Btuh Ceiling total 605 sqft 790 Btuh Windows(9.4%) Floor total 605 sqft 9192 Btuh Infiltration 36 cfm 1626 Btuh Duct loss 0 Btuh Subtotal 17030 Btuh Infi)(9.5%) Ventilation 0 cfm 0 Btuh ( Fioors(54.0%) TOTAL HEAT LOSS 17030 Btuh Doors(4.4%) SUMMER CALCULATIONS Summer Cooling Load (for 1170 sqft) Load component Load Window total 130 sqft 2996 Btuh Wall total 969 sqft 1677 Btuh Door total 40 sqft 409 Btuh 1eilings(8.4%) Y►'indows(28.946) Ceiling total 605 sqft 867 Btuh Floor total 0 Btuh Infiltration 27 cfm 595 Btuh Internal gain 2120 Btuh •h'slls(15.2%Tj Duct gain 0 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 8663 Btuh Latent int(7.7%) Doors(3.9%) Latent gain(ducts) 0 Btuh Latent gain(infiltration) 901 Btuh Latent gain(ventilation) 0 Btuh 1 Int-1l.(14.4%) Latent gain(internal/occupants/other) 800 Btuh Int.Gain(20.5%) Total latent gain 1701 Btuh TOTAL HEAT GAIN 10364 Btuh peseint EnergyGauge®System Sizing 8th Edition PREPARED BY: DATE: Malik 3. EnergyGauge®/USRCZB v5.1 Residential Window Diversity MidSummer Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 9/19/2017 Weather data for: Jacksonville -Defaults Summer design temperature 95 F Average window load for July 2275 Btuh Cooling setpoint 75 F Peak window load for July 4083 Btuh Summer temperature difference 20 F Excusion limit(130%of Ave.) 2957 Btuh Latitude 30.5 North Window excursion (July) 1126 Btuh WINDOW Average and Peak Loads _ _....i 4O D - .s. i 3,c , — r i � F it 2, ,G ..Rt s' .-... x 1 I 2.DC' b"� ..( . l-r+r 1 e,. ,Da,,", S 10 12 14 16 18 2'D • WindowLoad (NW --• Limltforexcursion I -'- 12 Hour Average Total July Window Load(Radiation and conduction) This application has glass areas that produce large heat gains for part of the day. Variable air volume devices are required to overcome spikes in solar gain for one or more rooms. Install a zoned system or provide zone control for problem rooms. Single speed equipment may not be suitable for the application. P.wnrw EnergyGauge®System Sizing for Florida residences only .... PREPARED BY: DATE: MIINUf11,.a EnergyGauge®/USRCZB v5.1 Residential Window Diversity October Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 9/19/2017 Weather data for: Jacksonville -Defaults Summer design temperature 95 F Average window load for October 2036 Btuh Cooling setpoint 75 F Peak window load for October 3411 Btuh Summer temperature difference 20 F Excusion limit(130% of Ave.) 2646 Btuh Latitude 30.5 North Window excursion (October) 765 Btuh WINDOW Average and Peak Loads 1 . . 3.03D ' ' 1 1 2,503 1 �" 2.0 337.761r74---. .—. .. i • 1,533 • 1, 33 �. 8 13 12 14 1E 18 2 ' WIndow Load (Bbill) Limitforexcursion 12 Hour Average Total October Window Load(Radiation and conduction) Warning: This application has glass areas that produce relatively large heat gains for part of the day. Variable air volume devices may be required to overcome spikes in solar gain for one or more rooms.A zoned system may be required or some rooms may require zone control. EnergyGauge®System Sizing for Florida residences only PREPARED BY: fs DATE: MN1�1itl ] "dr- EnergyGauge®/USRCZB v5.1 System Sizing Calculations - Winter Residential Load - Whole House Component Details Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 Building Type: User 9/19/2017 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 41.0 F (TMY3 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 1 2, NFRC 0.30 Vinyl 0.30 W 13.8 12.3 169 Btuh 2 2, NFRC 0.30 Vinyl 0.30 W 13.8 12.3 169 Btuh 3 2, NFRC 0.30 Vinyl 0.30 N 10.3 12.3 127 Btuh 4 2, NFRC 0.30 Vinyl 0.30 N 6.0 12.3 74 Btuh 5 2, NFRC 0.30 Vinyl 0.30 W 15.5 12.3 191 Btuh 6 2, NFRC 0.30 Vinyl 0.30 W 15.5 12.3 191 Btuh 7 2, NFRC 0.30 Vinyl 0.30 N 10.3 12.3 127 Btuh 8 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh 9 2, NFRC 0.30 Vinyl 0.30 E 15.5 12.3 191 Btuh 10 2, NFRC 0.30 Vinyl 0.30 E 15.5 12.3 191 Btuh Window Total 130.0(sqft) 1599 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame-Wood -Ext (0.077) 19.0/0.0 112 3.17 356 Btuh 2 Frame-Wood - Ext (0.077) 19.0/0.0 233 3.17 738 Btuh 3 Frame-Wood - Ext (0.077) 19.0/0.0 140 3.17 444 Btuh 5 Frame-Wood -Ext (0.077) 19.0/0.0 129 3.17 409 Btuh 6 Frame-Wood - Ext (0.077) 19.0/0.0 225 3.17 714 Btuh 7 Frame-Wood -Ext (0.077) 19.0/0.0 129 3.17 409 Btuh Wall Total 969(sqft) 3069 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated - Exterior, m (0.460) 20 18.9 377 Btuh 2 Insulated- Exterior, m (0.460) 20 18.9 377 Btuh Door Total 40(sqft) 754Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/L/Shing (0.032) 30.0/0.0 605 1.3 790 Btuh Ceiling Total 605(sqft) 790Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 190.0 ft(perim.) 48.4 9192 Btuh Floor Total 605 sqft 9192 Btuh Envelope Subtotal: 15405 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.23 9360 1.00 36.1 1626 Btuh Duct load Average sealed, R6.0, Supply(Con), Return(Con) (DLM of 0.000) 0 Btuh All Zones Sensible Subtotal All Zones 17030 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 Building Type: User 9/19/2017 111VHOLE HOUSE TOTALS Subtotal Sensible Heat Loss 17030 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 17030 Btuh EQUIPMENT 1. Electric Heat Pump # 23500 Btuh Preind Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge®/USRCZB v5.1 Page 2 System Sizing Calculations - Summer Residential Load - Whole House Component Details Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 9/19/2017 Reference City: Jacksonville, FL Temperature Difference: 20.OF(TMY3 99%) Humidity difference: 49gr. Component Loads for Whole House Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 2 NFRC 0.30,0.30 B-L No W 6.0ft 1.0ft 13.8 10.6 3.2 9 25 174 Btuh 2 2 NFRC 0.30,0.30 B-L No W 6.0ft 1.0ft 13.8 10.6 3.2 9 25 174 Btuh 3 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 10.3 0.0 10.3 9 9 92 Btuh 4 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 6.0 0.0 6.0 9 9 54 Btuh 5 2 NFRC 0.30,0.30 B-L No W 6.0ft 1.0ft 15.5 11.9 3.6 9 25 195 Btuh 6 2 NFRC 0.30,0.30 B-L No W 6.0ft 1.0ft 15.5 11.9 3.6 9 25 195 Btuh 7 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 10.3 0.0 10.3 9 9 92 Btuh 8 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 13.8 0.0 13.8 9 9 123 Btuh 9 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 15.5 0.0 15.5 9 25 385 Btuh 10 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 15.5 0.0 15.5 9 25 385 Btuh Excursion 1126 Btuh Window Total 130 (sqft) 2996 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Wood-Ext 0.08 19.0/0.0 112.4 1.7 195 Btuh 2 Frame-Wood-Ext 0.08 19.0/0.0 233.0 1.7 403 Btuh 3 Frame-Wood-Ext 0.08 19.0/0.0 140.0 1.7 242 Btuh 5 Frame-Wood-Ext 0.08 19.0/0.0 129.0 1.7 223 Btuh 6 Frame-Wood-Ext 0.08 19.0/0.0 225.2 1.7 390 Btuh 7 Frame-Wood-Ext 0.08 19.0/0.0 129.0 1.7 223 Btuh Wall Total 969(sqft) 1677 Btuh Doors Type Area (sqft) HTM Load 1 Insulated-Exterior 20.0 10.2 205 Btuh 2 Insulated-Exterior 20.0 10.2 205 Btuh Door Total 40(sqft) 409 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Shingle 0.032 30.0/0.0 605.0 1.43 867 Btuh Ceiling Total 605 (sqft) 867 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 605(ft-perimeter) 0.0 0 Btuh Floor Total 605.0(sqft) 0 Btuh Envelope Subtotal: 5949 Btuh Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.17 9360 1 27.1 595 Btuh Internal Occupants Btuh/occupant Appliance Load gain 4 X 230 + 1200 2120 Btuh Sensible Envelope Load: 8663 Btuh Duct load Average sealed,Supply(R6.0-Condi),Retum(R6.0-Condi) (DGM of 0.000) 0 Btuh Sensible Load All Zones 8663 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 9/19/2017 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 8663 Btuh Sensible Duct Load 0 Btuh Total Sensible Zone Loads 8663 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 8663 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 901 Btuh Latent ventilation gain 0 Btuh Latent duct gain 0 Btuh Latent occupant gain (4.0 people @ 200 Btuh per person) 800 Btuh Latent other gain 0 Btuh Latent total gain 1701 Btuh TOTAL GAIN 10364 Btuh EQUIPMENT 1. Central Unit # 22700 Btuh *Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No), Blinds(B),Draperies(D)or Roller Shades(R)) Assiork - For Blinds:Assume medium color, half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed (IS-Insect screen:none(N), Full(F)or Half(%)) (Ornt-compass orientation) 4j0V. Version 8 EnergyGauge®/USRCZB v5.1 Page 2 System Sizing Calculations - Winter Residential Load - Room by Room Component Details Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 Building Type: User 9/19/2017 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 41.0 F (TMY3 99%) Component Loads for Room#1: 1st Floor Window Panes/Type Frame U Orientation Area(sgft) X HTM= Load 1 2, NFRC 0.30 Vinyl 0.30 W 13.8 12.3 169 Btuh 2 2, NFRC 0.30 Vinyl 0.30 W 13.8 12.3 169 Btuh 3 2, NFRC 0.30 Vinyl 0.30 N 10.3 12.3 127 Btuh 4 2, NFRC 0.30 Vinyl 0.30 N 6.0 12.3 74 Btuh Window Total 43.9(sgft) 540 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame-Wood -Ext (0.077) 19.0/0.0 112 3.17 356 Btuh 2 Frame -Wood -Ext (0.077) 19.0/0.0 233 3.17 738 Btuh 3 Frame-Wood -Ext (0.077) 19.0/0.0 140 3.17 444 Btuh Wall Total 485(sgft) 1538 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated -Exterior, m (0.460) 20 18.9 377 Btuh 2 Insulated-Exterior, m (0.460) 20 18.9 377 Btuh Door Total 40(sgft) 754Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/L/Shing (0.032) 30.0/0.0 605 1.3 790 Btuh Ceiling Total 605(sgft) 790Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 190.0 ft(perim.) 48.4 9192 Btuh Floor Total 605 sgft 9192 Btuh Room Envelope Subtotal: 12814 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.23 4520 0.50 18.1 815 Btuh Duct load Average sealed,Supply(R6.0-Cond.),Return(R6.0-Cond.) (DLM of 0.000) 0 Btuh Room #1 Sensible Room Subtotal 13629 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 Building Type: User 9/19/2017 Component Loads for Room#2: 2nd Floor Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 5 2, NFRC 0.30 Vinyl 0.30 W 15.5 12.3 191 Btuh 6 2, NFRC 0.30 Vinyl 0.30 W 15.5 12.3 191 Btuh 7 2, NFRC 0.30 Vinyl 0.30 N 10.3 12.3 127 Btuh 8 2, NFRC 0.30 Vinyl 0.30 N 13.8 12.3 169 Btuh 9 2, NFRC 0.30 Vinyl 0.30 E 15.5 12.3 191 Btuh 10 2, NFRC 0.30 Vinyl 0.30 E 15.5 12.3 191 Btuh Window Total 86.1(sqft) 1059 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 5 Frame -Wood -Ext (0.077) 19.0/0.0 129 3.17 409 Btuh 6 Frame -Wood -Ext (0.077) 19.0/0.0 225 3.17 714 Btuh 7 Frame-Wood - Ext (0.077) 19.0/0.0 129 3.17 409 Btuh Wall Total 483(sqft) 1531 Btuh Room Envelope Subtotal: 2590 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.23 4840 0.50 18.0 811 Btuh Duct load Average sealed,Supply(R6.0-Cond.),Return(R6.0-Cond.) (DLM of 0.000) 0 Btuh Room #2 Sensible Room Subtotal 3401 Btuh WHOLE HOUSE TOTALS Subtotal Sensible Heat Loss 17030 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss17030 Btuh EQUIPMENT 1. Electric Heat Pump # 23500 Btuh EnergyGauge®/USRCZB v5.1 Page 2 Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 Building Type: User 9/19/2017 Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) Poimiebt or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) MUM.1 Version 8 EnergyGauge®/USRCZB v5.1 Page 3 System Sizing Calculations - Summer Residential Load - Room by Room Component Details Project Title: 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 9/19/2017 Reference City: Jacksonville, FL Temperature Difference: 20.0F(TMY3 99%) Humidity difference:49gr. Component Loads for Room#1: 1st Floor Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 2 NFRC 0.30,0.30 B-L No W 6.0ft 1.Oft 13.8 10.6 3.2 9 25 174 Btuh 2 2 NFRC 0.30,0.30 B-L No W 6.0ft 1.0ft 13.8 10.6 3.2 9 25 174 Btuh 3 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 10.3 0.0 10.3 9 9 92 Btuh 4 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 6.0 0.0 6.0 9 9 54 Btuh Window Total 44 (sqft) 493 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Wood-Ext 0.08 19.0/0.0 112.4 1.7 195 Btuh 2 Frame-Wood-Ext 0.08 19.0/0.0 233.0 1.7 403 Btuh 3 Frame-Wood-Ext 0.08 19.0/0.0 140.0 1.7 242 Btuh Wall Total 485(sqft) 840 Btuh Doors Type Area(sqft) HTM Load 1 Insulated-Exterior 20.0 10.2 205 Btuh 2 Insulated-Exterior 20.0 10.2 205 Btuh Door Total 40(sqft) 409 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Shingle 0.032 30.0/0.0 605.0 1.43 867 Btuh Ceiling Total 605 (sqft) 867 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 605(ft-perimeter) 0.0 0 Btuh Floor Total 605.0 (sqft) 0 Btuh Zone Envelope Subtotal: 2610 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.17 4520 0.50 13.6 298 Btuh Internal Occupants Btuh/occupant Appliance Load gain 0 X 230 + 1200 1200 Btuh Sensible Envelope Load: 4108 Btuh Duct load Average sealed,Supply(R6.0-Cond.),Return(R6.0-Cond.) (DGM of 0.000) 0 Btuh Sensible Zone Load 4108 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_JACKSONVILLE_INTL ARPT 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 9/19/2017 Component Loads for Room#2: 2nd Floor Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 5 2 NFRC 0.30,0.30 B-L No W 6.0ft 1.0ft 15.5 11.9 3.6 9 25 195 Btuh 6 2 NFRC 0.30,0.30 B-L No W 6.0ft 1.Oft 15.5 11.9 3.6 9 25 195 Btuh 7 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 10.3 0.0 10.3 9 9 92 Btuh 8 2 NFRC 0.30,0.30 B-L No N 1.0ft 1.0ft 13.8 0.0 13.8 9 9 123 Btuh 9 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.0ft 15.5 0.0 15.5 9 25 385 Btuh 10 2 NFRC 0.30,0.30 B-L No E 1.0ft 1.Oft 15.5 0.0 15.5 9 25 385 Btuh Window Total 86(sqft) 1377 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 5 Frame-Wood-Ext 0.08 19.0/0.0 129.0 1.7 223 Btuh 6 Frame-Wood-Ext 0.08 19.0/0.0 225.2 1.7 390 Btuh 7 Frame-Wood-Ext 0.08 19.0/0.0 129.0 1.7 223 Btuh Wall Total 483 (sqft) 836 Btuh Zone Envelope Subtotal: 2213 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.17 4840 0.50 13.5 297 Btuh Internal Occupants Btuh/occupant Appliance Load gain 4 X 230 + 0 920 Btuh Sensible Envelope Load: 3430 Btuh Duct load Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DGM of 0.000) 0 Btuh Sensible Zone Load 3430 Btuh The following window Excursion will be assigned to the system loads. Windows July excursion for System 1 1126 Btuh Excursion Subtotal: 1126 Btuh Duct load 0 Btuh Sensible Excursion Load 1126 Btuh EnergyGauge®/USRCZB v5.1 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT 168 SANDY BEACH LANE HABITAT-QUADPLEX-OUTSIDE-D168 ATLANTIC BEACH , FL 32233 9/19/2017 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 8663 Btuh Sensible Duct Load 0 Btuh Total Sensible Zone Loads 8663 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 8663 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 901 Btuh Latent ventilation gain 0 Btuh Latent duct gain 0 Btuh Latent occupant gain (4.0 people @ 200 Btuh per person) 800 Btuh Latent other gain 0 Btuh Latent total gain 1701 Btuh TOTAL GAIN 10364 Btuh EQUIPMENT 1. Central Unit # 22700 Btuh *Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No), Blinds(B),Draperies(D)or Roller Shades(R)) hipprait - For Blinds:Assume medium color,half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed �:` (IS-Insect screen:none(N), Full(F)or Half(%)) (Ornt-compass orientation) Version 8 EnergyGauge®/USRCZB v5.1 Page 3 Manual S Compliance Report Job: 168 SB Lane - + wrightsoft Manual 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140E 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 17608 Btuh Entering coil DB: 76.9°F Outdoor design WB: 77.0°F Latent gain: 3181 Btuh Entering coil WB: 63.6°F Indoor design DB: 75.0°F Total gain: 20789 Btuh Indoor RH: 50% Estimated airflow: 700 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 700 cfm Sensible capacity: 18041 Btuh 102%of load Latent capacity: 4022 Btuh 126%of load Total capacity: 22063 Btuh 106%of load SHR: 82% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 19908 Btuh Entering coil DB: 68.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 700 cfm Output capacity: 18689 Btuh 94%of load Capacity balance: 29 °F Supplemental heat required: 1219 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 700 cfm Output capacity: 4.7 kW 81%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. 2017-Oct-17 20:15:03 r., wrightsoft Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 AL;UPIX ...\Beaches Habitat\168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE Project Summa Job: 168 SB Lane 4 wrightsoft ry Date: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308.Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: Beaches Habitat Notes: 168 Sandy Beach Lane Desi• n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16590 Btuh Structure 14673 Btuh Ducts 3318 Btuh Ducts 2935 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19908 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17608 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2100 Btuh Ducts 1081 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1140 1140 Equipment latent load 3181 Btuh Volume(ft') 9920 9920 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 20789 Btuh Equiv. AVF (cfm) 74 38 Req.total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A00300 Cond 25HBC524A00300 AHRI ref 9154698 Coil FX4DNF025L AHRI ref 9154698 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 16800 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 7200 Btuh Temperature rise 31 °F Total cooling 24000 Btuh Actual air flow 700 cfm Actual air flow 700 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=29°F Backup: Input=5 kW, Output= 16145 Btuh, 100 AFUE Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t i htsoft 2017-Oct-1720:15:03 w g Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 , C ...\Beaches Habitat\168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE 4 wrightsoft Right-J® Worksheet Job: 168 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Pllan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Entire House Kitchen 2 Exposed wall 204.0 ft 25.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 14.0 x 11.0 ft 5 Room area 1240.0 f t' 154.0 f t' i i i r Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') Load number (Bt uh/fV-°F (Btuh/ft') I or perimeter (ft)ft (Btuh) or perimeter (ft) (Btuh) 1 Heat I Cool I Gross I N/P/S Heat 1 Cool I Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 496+ 496 1265 712 88 88 224 126 12E-Osw 0.068 se 2.55 1.43 320 239 609 343 0 0 0 0 1D-c2ow 0.570 se 21.38 38.87 31 4 667 1213 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 15 11 315 355 0 0 0 0 11 1D-c2ow 0.570 se 21.38 18.20 15 15 315 268 0 0 0 0 D 11D0 0.390 se 14.62 11.78 20 20 298 240 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 496 454 1159 652 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 36.78 6 1 128 221 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 21 3 445 809 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 15 2 315 573 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 320 248 632 356 112 92 234 131 1D-c2ow 0.570 nw 21.38 39.24 31 0 667 1224 0 0 0 0 11D0 0.390 nw 14.62 11.78 41 41 597 481 20 20 298 240 C 16B-30ad 0.032 - 1.20 1.72 144 144 173 247 28 28 34 48 C 16B-7ad 0.112 - 4.20 6.01 496 496 2083 2983 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 640 104 3857 0 154 25 927 0 6 1 c)AED excursion 333 -263 Envelope loss/gain 1 1 135251 110091 1 17171 283 12 a) Infiltration 3065 744 376 91 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 2000 2000 Subtotal(lines 6 to 13) 16590 14673 2093 2374 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 0 0 394 138 14 Subtotal 16590 14673 2487 2512 15 Duct loads 20% 20% 3318 2935 20% 20% 497 502 Air Totalreqrouiromed load(cfrn) I I 199081 176081 I I 29851 30141 700 700 105 120 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' wrightsoft Rig Universal 2017 17.0.29 RSU09479 2017-Oct-17 20:15:03 P Page 1 ...\Beaches Habitat1168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE wrightsoft Right-J® Worksheet Job: 168 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Py Plan: 1140E 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Utility Bath 1 2 Exposed wall 10.0 ft 9.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 4.0 ft 6.0 x 9.0 ft 5 Room area 24.0 ft' 54.0 ft' I I I I r r Ty Construction U-value Or 1 HTM Area (ft') Load I Area (ft') Load number (Bt uh/tt'-°F (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) r IHeat I Cool I Gross N/P/S Heat I Cool Gross I N/P/S I Heat I Cool 6 W 12E-Osw 0.068 ne { 2.55 1.43 0 0 0 O0 Of 0 0 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1D-clow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-clow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 11 1D-c2ow 0.57D se 211.38 18.20 0 0 0 0 0 0 0 0 O 11 DO 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 v 12E-Osw 0.068 sw 2.55 1.43 32 32 82 46 72 66 168 95 -G 1 D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 6 1 128 221 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 12E-Osw 0.068 nw 2.55 1.43 48 28 70 40 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 D 11 D0 0.390 nw 14.62 11.78 20 20 298 240 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 12 12 14 21 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 24 10 371 0 54 9 334 0 6I c)AED excursion I I 381 I I831 If Envelope loss/gain 836 3081 It 630 398 12 a) Infiltration 150 36 135 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 986 345 766 431 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -986 -345 719 231 14 Subtotal 0 0 1485 662 15 Duct loads 20% 20% 0 0 20% 20% 297 132 Total room load I I 0 I 17821 794 Air required(cfm) 0 001 63 f 32 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightSoft 2017-Oct-17 20:15:03 Rig ht-Suite®Universal 2017 17.0.29 RSU09479 Page 2 ...\Beaches Habitat\168 Sandy Beach Lane\1140L,rup Calc=MJ8 Front Door faces:SE -f'►- wrightsoft Right-J® Worksheet Job: 168 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Pllan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Great Mech 2 Exposed wall 55.0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 378.0 ft 6.0 x 5.0 ft 5 Room area 378.0 ft' I 30.0 ft' I i r Ty Construction U-value OrHTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F I (Btuh/ft') or erimeter p (ft) (Btuh) 1I or perimeter (ft) (Btuh) Heat ! Cool 1 Gross I N/P/S Heat Cool 1 Gross I N/P/S Heat I Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 168 168 428 241 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 160 110 281 158 0 0 0 0 1D-c2ow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 15 11 315 355 0 0 0 0 11 1D-c2ow 0.570 se 21.38 18.20 15 15 315 268 0 0 0 0 O 1100 0.390 se 14.62 11.78 20 20 298 240 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 112 102 259 146 40 40 102 57 -G 1D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 10 1 222 404 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 165-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 378 55 2040 0 30 5 185 0 1 6 1 c)AED excursion -201 -8 Envelope loss/gain 1 ( 41591 16121 1 287 50 12 a) Infiltration 826 201 75 18 b) Room ventilation 0 0 o 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4985 1812 363 68 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 235 44 -363 -68 14 Subtotal 5220 1856 0 0 15 Duct loads 20% 20% 1044 371 20% 20% 0 0 Toroo6264 2228 I Air tal requiredm (cfmload) I I I 2201 89 l 1 001 00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - 'TT wrighisa Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-1720:15:03 Page 3 ...\Beaches Habitat\168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE 4 wrightsoft Right-J® Worksheet Job: 168 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name M WIC Master 2 Exposed wall 12.0 ft 23.0 ft 3 Room height 8.0 ft heaUcool 8.0 ft heat/cool 4 Room dimensions 7.0 x 5.0 ft 13.0 x 10.0 ft 5 Room area 35.0 ft' 130.0 ft' i i I i i Ty Construction U-value Or HTM (ft') Load ( Area (ft') Load number (Bt uh/ft'-°F (Btuh/ft') orperimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross N/P/S Heat I Cool I Gross N/P/S Heat I Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 80 80 204 115 12E-Osw 0.068 se 2.55 1.43 56 56 143 80 104 73 186 104 1D-c2ow 0.570 se 21.38 38.87 0 0 0 0 31 4 667 1213 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 11 1D1-c2ow 0.570 0 0 0 0 0 0 0 0 0 1100 0.390 sese 211.38 14.62 18.208 11.7 0 0 0 0 0 0 0 0 VI 12E-Osw 0.068 sw 2.55 1.43 40 40 102 57 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 10-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 35 35 42 60 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 130 130 546 782 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 61 c)AED excursion -24 I I I 325 Envelope loss/gain 287 174 ly 160311 2539 12 a) Infiltration 180 44 346 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 467 217 1948 3083 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 160 189 280 329 14 Subtotal 627 406 2228 3412 15 Duct loads 20% 20% 125 81 20% 20% 446 682 o 753 487 2674 4094 AirTotal requroirmedload(cfm) I I l 261 191 I l 941 1631 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. :� wri9hts®ft 2017-Oct-17 20:15:03 X Rig ht-Su ite®U niv ersal 2017 17.0.29 RSU09479 Page 4 ...\Beaches Habitat\168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE '' " wrightsoft Right-J® Worksheet Job: 168 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name M Linen Bath 2 2 Exposed wall 0 ft 9.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 3.0 x 5.0 ft 6.0 x 9.0 ft 5 Room area 15.0 ft' 54.0 ft' r I h i h h Ty Construction U-value Or I HIM Area (f(') LoadArea (ft') Load number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) fI (Btuh) I or perimeter (ft) (Btuh) rI C Heat I Cool I Gross I N/P/S I Heat Cool I Gross I N/P/S Heat I Cool 6 W 12E-Osw 0.068 ne 2.55` 1.43 0 0 0 0 72 72 184 103 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 11D0 0.390 se 14,62 11.78 0 0 0 0 0 0 0 0 V/ 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 0 0 0 0 -0 1D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 -0 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 hD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-3Oad 0.032 - 1.20 1.72 15 15 18 26 54 54 65 93 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 I c)AED excursionloss/gain I I I 181 23I I -23 Envelope 248 173 12 a) Infiltration 0 0 135 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 18 23 384 206 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 0 0 10 -23 345 405 14 Subtotal 0 0 729 61111 15 Duct loads 20% 20% 0 0 20% 20% 146 122 Air Totalrequirroomed load(cfm) I I 00l OOI I I 8751 733 31 29 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. j wrightsoft Right-Suite®Universa1201717.0.29 RSU09479 2017-Oct-1720:15:03 " ...\Beaches Habitat\168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE Page 5 " wrightsoft Right-J® Worksheet Job: 168 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bed 3 Bed 2 2 Exposed wall 21.0 ft 21.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 11.0 ft 10.0 x 11.0 ft 5 Room area 110.0 ft' 110.0 ft' 1 i I I Ty Construction U-value Or I HTM Area (ft') Load I Area (f t') ( Load number (Btuh/ft'-°F I (Btuh/ft') I I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)` Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 W '12E-Osw 0.068 ne 2.55 1.43 88 88 224 126 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 11D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 V/ 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 88 73 187 105 G 1D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 -C 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 15 2 315 573 HD12E-Osw 0.068 nw 2.55 1.43 80 64 164 92 80 64 164 92 1D-c2ow 0.570 nw 21.38 39.24 16 0 333 612 16 0 333 612 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 110 110 462 662 110 110 462 662 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 16I c)AED excursion 1 1 1 1371 1 299 Envelope loss/gain 1184 1629 1461 2343 12 a) Infiltration 316 77 316 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 1500 1936 1777 2649 r Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 154 180 384 450 14 Subtotal 1653 2116 2161 3099 15 Duct loads 20% 20% 331 423 20% 20% 432 620 Total room load 1984701 2539101( I I 259391 I 3718 Air required(cim) 1 I I 148 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2017-Oct-17 20:15:03 Right-Suite®Universal 2017 17.0.29 RSU09479 Page 6 ...\Beaches Habitat\168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE - wrightsoft Right-J® Worksheet Job: 168 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Loft 2 Exposed wall 14.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 1.0 x 146.0 ft 5 Room area 146.0 ft' r r I r r r Ty Construction U-value Or 1 HTM Area (ft') LoadArea Load number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) (Btuh) I or perimeter I IHeat I Cool Gross I N/P/S I Heat 1 Cool j I Gross I N/P/S I Heat I Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 12E-Osw 0.068 se 2.55 0 0 0 1D-clow 0.570 se 21.38 38.871.43 0 0 00 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 11 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 11 DO 0.390 se 14.62 11.78 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 112 102 259 146 -G 1D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 -G 1D-clow 0.570 sw 21.38 38.87 10 1 222 404 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 146 146 613 878 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 6 1 c)AED excursion 1 110951 14771 1 I 1 Envelope loss/gain 12 a) Infiltration 210 51 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1305 1529 Less external load 0 0 Less transfer 0 0 Redistribution -1305 -1529 14 Subtotal 0 0 15 Duct loads 20% 20% 0 0 Air r Air r equirroomed load(cfm) I I I 00OI Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgltts9ft Right-Suite°Universa1201717.0.29RSU09479 2017-Oct-1720:15:03 Page 7 ...\Beaches Habitat\168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE N 1st Floor ffawl"".emmi Utility Kitchen • - Bath 1 : cfm 120 cfm 6 " r10 " 6 " ri 1 .._ 700 cfm Mech 11 cfm 11 Sup Riser '., 2 • 6 " Great • 11 cfm _4.r Job#: 168 SB Lane Scale: 1 :48 Performed for: Florida Air Service & Engineering Beaches Habitat Page 1 150 Hilden Road 308 R ights uite®Universal 2017 Ponte Vedra,Fl 32081 17.0.29 RSU09479 Phone:904-823-9696 2017-Oct-17 20:15:22 WWW.NORTHFLORIDAAIR.COM ...t\168 Sandy Beach Lane11140L... N .epi► Ir 2nd Floor Bed 2 Bed 3 148 cfm 12x10 12x10 0.4 101 cfm IZI 0,4 6 " 6 " Sup Rise 12 " Bath 2 Loft `31 cfm 12x10 4 " VI Line^ 4 " 81 cfm Master :.4 26 cfm '81 cf M WIC Job#: 168 SB Lane Florida Air Service & EngineeringScale: 1 :48 Performed for: Page 2 Beaches Habitat 150 Hilden Road 308 RightSuite®Universal 2017 Ponte Vedra,Fl 32081 17.0.29 RSU09479 Phone:904-823-9696 2017-Oct-17 20:15:22 VWVW.NORTHFLORIDAAIR.COM ...t\168 Sandy Beach Lane\1140L... 4 Duct System Summary Job: 168 SB Lane wrightsoft Date: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140E 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Heating Cooling External static pressure 0.25 in H2O 0.25 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply/return available pressure 0.125/0.125 in H2O 0.125/0.125 in H2O Lowest friction rate 0.100 in/100ft 0.100 in/100ft Actual air flow 700 cfm 700 cfm Total effective length (TEL) 132 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual I, Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 1 h 1782 63 32 0.100 4.0 Ox 0 VIFx 15.2 100.0 st4 Bath 2 h 875 31 29 0.100 4.0 Ox 0 VIFx 0 0 Bed 2 c 3718 91 148 0.100 6.0 Ox 0 VIFx 19.6 110.0 st1 Bed 3 c 2539 70 101 0.100 6.0 Ox 0 VIFx 16.2 110.0 st1 Great h 3132 110 44 0.100 6.0 Oxo VIFx 15.6 100.0 st4 Great-A h 3132 110 44 0.100 6.0 Oxo VIFx 24.6 100.0 st4 Kitchen c 3014 105 120 0.100 6.0 Ox 0 VIFx 11.6 100.0 st4 M wlc h 753 26 19 0.100 4.0 Ox 0 VIFx 22.4 110.0 st1 Master c 2047 47 81 0.100 4.0 Ox 0 VIFx 14.9 110.0 st1 Master-A c 2047 47 81 0.100 4.0 Ox 0 VIFx 0 0 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 234 350 0.100 445 12.0 0 x 0 VinlFlx st4 Peak AVF 388 240 0.100 711 10.0 0 x 0 VinIFIx st2 st2 Peak AVF 388 240 0.100 711 10.0 0 x 0 VinlFlx Bold/italic values have been manually overridden 2017-Oct-17 20:15:04 P.:.�, wrightsoft Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 J..:C. ...\Beaches Habitat\168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 700 700 0 0.080 655 14.0 Ox 0 VIFx WI'1 htSoft 2017-Qct-17 20:15:04 � �"' 9 Right-Suite®Universal 2017 17.0.29 RSU09479 CU1/4 ...\Beaches Habitat1168 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE Page 2