Loading...
1678 ATLANTIC BEACH DR - NEW HOME PERMIT ,,,_,,, r�S ' _ , � CITY OF ATLANTIC BEACH . v ? 800 SEMINOLE ROAD 7-fKATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0039 Description: new single-family home Estimated Value: 405124.6 Issue Date: 2/26/2018 Expiration Date: 8/25/2018 PROPERTY ADDRESS: Address: 1678 ATLANTIC BEACH DR RE Number: 169505 1720 PROPERTY OWNER: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD HORSHAM, PA 19044 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: TOLL BROS.,INC Address: 250 GIBRALTAR RD STEVEN R MERTEN HORSHAM, PA 19044 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. Ly Jo y,S r 4 f • Permit Conditions City of Atlantic Beach 9r Permit Number: RES18-0039 Description: new single-family home Applied: 1/24/2018 Approved: 2/4/2018 Site Address: 1678 ATLANTIC BEACH DR Issued:2/26/2018 Finaled: City,State Zip Code:ATLANTIC BEACH, FL 32233 Status: ISSUED Applicant: <NONE> Parent Permit: Owner:TOLL FL VI LIMITED PARTNERSHIP Parent Project: Contractor:<NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 1/26/2018 DRIVEWAY APRON INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All concrete driveway aprons must be 5"thick,4000 psi,with fibermesh from edge of pavement to the property line.Reinforcing rods or mesh are not allowed in the right-of-way. (Commercial driveways-6"thick). 2 1/26/2018 EROSION CONTROL INSTALLATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(247- 5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 3 1/26/2018 ON SITE RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site during construction. 4 1/26/2018 ROLL OFF CONTAINER INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapell's,Inc.,Republic Services,Donovan Dumpsters). Container cannot be placed on City right-of-way. 5 1/26/2018 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. Printed: Monday,26 February, 2018 1 of 2 �, `' ri� Permit Conditions rt �� City of Atlantic Beach 6 1/26/2018 RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site. Cannot raise lot elevation. 7 1/31/2018 UNDERGROUND WATER SEWER INFORMATIONAL UTILITIES PUBLIC WORKS Kayle Moore Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5834. 8 1/31/2018 METER BOX SEWER CLEAN OUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible. 9 1/31/2018 RT1 SEWER CLEANOUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. Printed: Monday, 26 February, 2018 2 of 2 • 1 ijikr City of Atlantic Beach APPLICATION NUMBER L Building Department (To be assigned by the Building Department.) r A >9 800 Seminole Road f E S I S— 00 3 -e Atlantic Beach, Florida 32233-5445 Y U Phone (904)247-5826 • Fax(904)247-5845 \\1`-1 Date routed: I IJ ` I �? E-mail: building-dept@coab.us City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: run / Lu (1 L LlC� Di, De artment review required Yes No Applicant: \ D t l wS . -�"Y' ( i) - Planning &Zon , Tree A ministrator Project: �( c..� J1 ��\�` . CI(e1. �.� V1.0 P b.l.i ks Public Utilities Public Safety Fire Services Review fee $ Dept Signature Review or Receipt Other Agency Review or Permit Required Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ['Approved as revised. ['Denied. I INot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. Not applicable Comments: Date: Reviewedby: Revised 05/19/2017 owtf, City of Atlantic Beach APPLICATION NUMBER R• Building Department (To be assigned by the Building Department.) r ''A `` 800 Seminole Road P C �( �.2 Atlantic Beach, Florida 32233-5445 r `� u— © 0 1 Phone(904)247-5826 • Fax(904) 247-5845 ' / t y?a;3 E-mail: building-dept@coab.us Date routed: I City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: /loll A�(a.p{,L Cvl p Department review required Ye No 3il am Applicant: \ D R YDS. ,T n( Pfanning &Zonm 1 Tree Administrator Project: '11 -. ) S1 G1\ .- ..V t (v\ �I �IC�i'U.. P 4bti ' ks dJ (ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ®'6enied. ❑Not applicable (Circle one.) Comments: BUILDIN PLANNINd &ZONING '1 ° t Reviewed by: Date: TREE ADMIN. Second Review: Wpproved as revised. ['Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: 2-'/ 3--20(r FIRE SERVICES Third Review: Approved as revised. C2T ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 r=� __ ,, ,,�t 'r,& Building Permit Application ',OFFICE C''OCity of Atlantic Beach JAN 2. 4 2018 �li �1 j'Mr 'O Seminole Road,Atlantic Beach, FL 32233 _ID 1 -cm`'~ Phone: (904) 247-5826 Fax: (904) 247-5845 t Job Address: 1678 Atlantic Beach Drive Permit Number: ?(_---_,S1 �--- 0o j Legal Description Lot 85 Atlantic Beach Country Club Unit 2, Parcel# 67-52 16-25-29E RE# 169505-1720 Valuation of Work(Replacement Cost)$ 366869 Heated/Cooled SF_ 3164_ Non-Heated/Cooled_ 974 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New home construction. Florida Product Approval# See attached. for multiple products use product approval form Property Owner Information Name: TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904-217-0739 E-Mail aregnierna tollbrothers.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) TOLL FL VI, LP Contractor Information Name of Company: Toll Bros., Inc. Qualifying Agent: Steven R. Merten Address 160 Cape May Avenue City PonteNedra State FL Zip 32081 Office Phone 904-595-5243 Job Site/Contact Number 904-595-5243 State Certification/Registration# CGC1510225 E-Mail aregnier@tollbrothers.com Architect Name&Phone# Toll Architecture (407) 248-5800 Engineer's Name& Phone# Lou Pontigo & Associates (904) 242-0908 Workers Compensation Policy#MWC30267702 / Expires: 9/1/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCIN 'ONSULT WITH YOUR LENDER OR AN ATTORNEY EFORE RECORDING YOUR ► • ' CE OF COMMENCEMENT. (Signatur of Ow - '. Agent including Contractor) (Sig re of Contractor) Si ned and sworn to(or affirmed)before me this 18 day of Signed and sworn to(or affirmed)before me this (8 day of ini�►zrt� 90I% ,by S1"' . Ib1e�'-Fen i COW 9 , OM ,by 3 e✓t Melfi-e."_ ►' :nature of Notary ignature of Notary) tP Notary Public State of Florida Notary Public State of Florida Melissa Sue Lieberman Melissa Sue Lieberman t; i My Commission GG 126068 v MyCommission GG 126068 [ Personally Known OR '''oc v:04° Expires 09/18/2021 [ Personally Know Oi3a, / Epires 09/18/2021 [ ]Produced Identificatio [ ]Produced Identi '_. , Type of Identification: Type of Identification: CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach, Florida 32233 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date 2/12/2018 Revision to Issued Permit Corrections to Comments X Permit# RES18-0039 Project Address 1678 Atlantic Beach Dr Contractor/Contact Name Audrey Regnier Phone 904.595.5243 Email aregnier@tollbrothers.com Description of Proposed Revision/Corrections: Permit Fee Due s O. 00 Revised window spec and attached metal roof install instructions • - • • ments. Additional Increase in Building Value $ Additional S.F. By signing below, I Audrey Regnier affirm the Revision is inclusive of the proposed changes. (printed name) 2/12/2018 Signature of Co ractor/Agent( ontractor must sign if increase in valuation) Date (Office Use Only) Approved �� Denied Not Applicable to Department Pp P Revision/Plan Review Comments De a artment Review Required: Building r t- Planning & Zoning f viewed By Tree Administrator m Public Works !, I FEB 1 ? 2018 Public Utilities i 3'c�Ol Public Safety Date Fire Services i CITY OF ATLANTIC BEACH - 800 SEMINOLE ROAD OFFICE ATLANTIC BEACH, FL 32233 COPY (904) 247-5800 ��Ji31�r� BUILDING REVIEW COMMENTS Date: 2/4/2018 Permit#: RES18-0039 Site Address: 1678 ATLANTIC BEACH DR Review Status: RE#: 169505 1720 Applicant: TOLL BROS.,INC Property Owner: TOLL FL VI LIMITED PARTNERSHIP Email: ARegnier@TOLLBROTHERSINC.COM Email: Phone: 9043866472 Phone: THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. u mit 2 copies of the manufacturer's installation instructions for the metal roof system, FL# 5211. '-6 . Window F, at the second floor#3 needs to be tempered according to R308.4.5 Glazing and wet surfaces.Window does not meet the exception by being more than 60 inches away.Submit revision for page A3.82 to show that the window is to •, -d. Cloud this on the drawing please,and at the window schedule page A3.N. 479^ 42.- Building —Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 904.247.5844 Email:mjones@coab.us mo't( eci 2 ifw ovrvv\pA5 C- L1-201 Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with • • i • DO NOT TE Ap Replica. e Coo es:2010 FLORIDA U DIN GCODE BELOW OFFICE USE ONLYview Jesuit circle one : Approved Disapproved ApprOVed^w/ Conditions Review Initials/Date: ( y- ci r Deyejopment Size .fabitable Space 303 F.Non-Habitable s- r: npervious area riscellaneous information ,cupancy Group IZ -3 pe of Construction V i3 tuber of Stories / ling District 4 6. 6-6 K. Occupancy Load Sprinklers Required d Zone )C lotions/Comments: 1=E = C)0. 3o ) • lr0 SP - 12, . 0 ) r FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION i Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: The Terrano Builder Name: McGowan's Heating&Air Con Street: Lot 85 Atlantic Beach CC Permit Office: Duval County City,State,Zip: Atlantic Beach,FL 32233 Permit Number. Owner. Toll Brothers,Inc. Jurisdiction: 261000 Design Location: FL,Jacksonville NAS County: (Florida Climate Zone 2) 1.New construction or existing New(From Plans) 9. Wall types(3627 fl2) Insulation Area(ftp 2.Single family or multiple family Single-Family a. Wood 2x6 Wall R19 R=19.0 3135.25 b. Wall 2x4 Adjacent To Garage R=13.0 491.55 3.Number of units,if multiple family 1 c. N/A R= 4.Number of bedrooms 4 d. N/A R= 10. Ceiling types(1789 ft2) Insulation Area(ft°) 5.Is this a worst case? No a. Shingles Vented Attic R3 R=21.0 1788.75 6.Conditioned floor area above grade(ft2) 3280.00 b. N/A R= . Conditioned floor area below grade(ftp 0 0. N/A R= 7. Windows(435 ft2) Description Area(ftp 11.D a.Sup: AttidRet:AttidAH:Main 6.0 Are 0 .00 a.U-Factor. Dbi,U=0.340 434.53 b. SHGC: SHGC=0.27 b.U-Factor. 12.Cooling systems kBtu/hr Efficiency SHGC: a.Split air source heat pump 47.0 SEER:14.5 c.U-Factor. SHGC: 13.Heating systems kBtu/hr Efficiency d.U-Factor. a.Split air source heat pump 44.0 HSPF:8.5 SHGC: Area Weighted Average Overhang Depth: 3.964 ft 14.Hot water systems Area Weighted Average SHGC: 0.270. a.Propane instantaneous(0 gal) Cap:0 gal EF:0.92 8. Floor types(2377.50 ft') Insulation Area(ft" b.Conservatlon features a. Frame Floor Over Ext R19 R=19.0 33.00 (None) b. Frame Floor Over Garage R11 R=11.0 172.50 c. Slab On Grade R=0.0 2172.00 15.Credits None Glass/Floor area: 0.132 Total Proposed Modified Loads: 69.04 ���� _ Total Baseline Loads: 78.03 I hereby certify that the plans and specifications covered by this Review of the plans and specifications • liti7t" calculation are in compliance with the Florida Energy Code. covered by this calculation indicates C•k .",7-,..--..,:?Z ' compliance with the Florida Energy s' .e'= Code.Before construction is completed, �a � �'' : this buildingwill be inspected for .Af "�t . , PREPARED BY: ' ;; l . compliance with Section 553.908 i I�i a DATE: 1/2/18 / / Florida Statutes. • r, (y b Atl I hereby certify that this building,as designed,is in compliance with t' I the Florida Energy Code. _ ,•a,QDrt 't . OWNER/AGENT: ,& S 1-/194-1,----- BUILDING OFFICIAL: DATE: \1 .1--ki/I DATE: -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017,this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). wirl,i�*11�7Ye:t!' "- Right-Stile®Universal 201818.0.O8RS000000 Right-Energy®Florida 2017 Sedion405.4.1CompliartSoftware 2018JarF021Page2 ...rssMcOowarfsH&A\Terrano3184-Lot85ABCC.rup Cale=MJ8 Front Door faces:E 6 �;S J\J'J;yr, City of Atlantic Beach APPLICATION NUMBER Js Building Department i s i (To be assigned by the Building Department.) 800 Seminole Road rc ( s 00 Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845.1,.,, , / _an 9„...40_� E-mail: building-dept@coab.us 2018 Date routed: ( ! City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: !1111' A-444{;L ) o De•artment review required Yes No : • ..,. Applicant: ` D U bps pS. "3-11( . Planning &Zonin• i Tree A. istrator Project: n -e St L" cunt �4 VI()rP = —A ks Public Utilities Pubic afety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING _ PLANNING &ZONING Reviewed b 'gpate: / 149 TREE ADMIN. Second Review: ['Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 • REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT,issued on this day of ,20 by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and TOLL FL VI.LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach Right-of-Way Permit# . This work is generally described as Pavers in the Right-of-Way for the driveway. • Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested,to the following address 1678 Atlantic Beach Dr, Parcel#67-132 08-2S-29E . • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described property of the CITY,the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining,repairing, operating,replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes,Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of public right-of-ways and other public land. US R further agrees that the CITY and its officers and employees shall be saved harmless by the USER from . if the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the ' '. ii Date / �Si/Z Property Owner:+tev • '.Merten,Division President,TOLL FL VI,LP (signed in press ce of Notary Public) STATE OF FLORIDA,COUNTY OF SAINT JOHNS The foregoing instrument was acknowledged this l a day of `q nu at ,2012 by ST{'c c plE-4 L1 i.l ,who personally appeared before me and (printed name of Signer) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. Olt Signature •f No . Public,State of Florida Approved/Public Works Department: Personally Known I ‘ Produced Identification(Type) /" � ) j-C-i���1---' r a Notary Public State of Fbrida Scott Williams, Pub it c Works Director `I `� Melissa Sue Lieberman 4 My Commission GG 126068 ~' ��acp Expires 09116/2021 }✓J t • r I) : RIGHT-OF-WAY/ EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 1678 Atlantic Beach Drive Phone 904-595-5243 Permittee Steven Morten Email aregnieratollbrothers.com Requesting Permission to Construct Pavers in the Right of Way for the driveway Location(Reference to Cross-Street) Coastal Oak Lane&Atlantic Beach Dr. -06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Stacia Moore (Project Superintendent) located at 237 9th Avenue North,Suite 4,Jacksonville Beach,FL 32250 . • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss, damage . •d cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid r'�/s and privileges. • The Direct. o' ' blic Works shall be notified twenty-four(24)hours prior to starting work and again immedia i.on completion. Date I hill? Permittee: S en ► erten,Division President,TOLLFL VI,LP(signed in presence of Notary Publ STATE OF ORIDA,COUNTY OF SAINT JOHNS The foregoing instrument was acknowledged this 1? day of_1A NUA421{, ,20 1?) , by S-i-- -- µ o2- \ ,,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. l PPersonally Known Signatal Notary Public,State of Florida Produced Identification(Type) Notary Public State of Florida Melissa Sue Lieberman ; hMy Commission GG 126086 ''►t«o Expires 09/18/2021 City of Atlantic Beach APPLICATION NUMBER Building Department C ''Vn (To be assigned by the Building Department.) `i 800 Seminole RoadJ c ( G O O 35 Atlantic Beach, Florida 32233-5445 oPhone(904)247-5826 • Fax(904) t47-5j4 " 2 5 2018 , / ,:yJ..il 9%- E-mail: building-dept@coab.us Date routed: I C-( I u City web-site: http://www.coab.us a:--- APPLICATION REVIEW AND TRACKING FORM Property Address: /Lon Department review required Yes No Applicant: I D ( Y o S. 71-r)( Ening & Zonin , J Tree Administrator Project: V\ Ls) fOnrk& P,iali1 ' ks e 1 ("Public Utilities Public afety Fire Services Review fee $ 550 Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI TION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: 44-5-4Al— Date: VI g ( k TREE ADMIN. Second Review: lApproved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach PUBLIC UTILITIES DEPARTMENT — ! i 1200 Sandpiper Lane ` Atlantic Beach, FL 32233 (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date /— 26 —/ d Project Address /(0 7 ' 474-k iri-c T3 O, Number of Units ( Commercial Residential Multi-Family 3 New Water Tap(s) & Meter(s) Meter Size(s) //ti New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size `t New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature �iCITY STAFF USE ONLY Application# l e=3 / O — OD 3 Water System Development Charge $ / y O r Ud AOC C Sewer System Development Charge $ S-6, c c Water Meter Only Reclaim Meter Only $ / 8S, on Water Meter Tap $ Sewer Tap $ Cross Connection $ SO . 06 Other $ TOTAL $ L.J; & /a, oo (Notes) APPROVED Kayle Moore, P.E. Date I/2 fill Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED TO L L A R C H I T E C T U R E OFFICE COPY MEMO TO: Stacia Moore Atlantic Beach Ambassador 160 Cape May Avenue Ponte Vedra, Florida 32081 CC: Audrey Regnier FROM: Manuel Gonzalez, AIA Toll Brothers, Inc. DATE: February 8, 2018 RE: Atlantic Beach Heritage - Lot 0085 Terrano - Coastal—Revision 1 AO#162585 On the above referenced lot,this letter shall be used to revise or clarify the following condition(s): Building Department Comments: 1. Bathroom 3 window adjacent to tub,labeled"F" on plans,should be tempered. 8308.4.5. Verify the height of window sill is more than 60 inches above walking or sitting surface at tub area. Toll Brothers responds: Window "F"is rename to window "L" Word "Tempered"Added to window "L"; clouded and tagged on sheets A 3.82&A3.N Sincerely, 4.4'41 OF FL" \ l i ° orf ° • 0 o AR9• 0 0 �j/ 1 %).. ). 0° 0° 4.0 ` D A Aff 411. �� f Manuel Gonzalez, AIA AR 96730 FLORIDA DIVISION 2966 Commerce Park Drive Suite 100 ■ Orlando,FL 32819 • (407)248-5800 • FAX:(407)248-5899 PHILADELPHIA ■ORLANDO ■ DALLAS ■ SEATTLE `roll`Brothels COMPANY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA OFFICE COP Y Project Name: Toll Brothers,Inc. Permit# Re-s/Q -06)39 Project Address: 1678 Atlantic Beach Drive,Atlantic Beach,FL 32233 Lot 0 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6 Single-FL6506.4 Simpson Door Company Wood Door FL 14487.1 Therma-Tru Fiberglass/Wood Door N/A FL 5262.3 — 2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251 3. Sectional Clopay Building Products Section Ext.Door +20/-20 PSF FL15279.1/FL15279.3 4.Roll up 5.Automatic 6.Other B. WINDOWS 1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435 2.Horizontal slider PGT 5400 Vinyl Hor.Window +50/-50 FL 1844 3. Casement 4.Double hung 5. Fixed PGT 5400 Vinyl Fixed Window +50/-50 , FL 5012 6.Awning _ 7. Pass-through 8.Projected _ 9.Mullion PGT Alum/Vinyl Mullions N/A FL 261 10.Wind Breaker 11.Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1 12. Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12 Category/Subcategory Manufacturer Product Description Limitation of Use State# O F F1C E c o C.PANEL WALL 1.Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4 FL 12098.3; 12098.1; Nichiha Corp. Lap Siding and Shingles N/A 12875.1 2.Soffits/Ceilings James Hardie Building Products,Inc. Soffit Panels N/A FL 13265.1 Nichiha Corp. Soffit Panels N/A FL 12098.4 3.EIFS 4.Storefronts Kawneer Glass Windows Mitred Glass +30/-30 FL 10008.1 5.Curtain walls 6.Wall louvers 7.Glass block 8.Membrane 9.Greenhouse 10.Synthetic Stucco 11.Other D.ROOFING PRODUCTS 1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1 2.Underlayments Woodland Industries,Inc. Felt N/A FL 1814.12 Boral Roofing Roof Underlayment N/A FL 14317.1 3.Roofing fastners 4.Nonstructural metal roof Millennium Metals,Inc. Metal Roofing-M seam N/A FL 5211.3 R6 5.Built-up roofing 6.Modified bitumen 7.Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing 11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake N/A FL 13714.1 12.Roofing slate 13.Liquid applied roofing 14.Cement-adhesive coats 15.Roof tile adhesive 16.Spray applied polyurethane roof 17.Other Pli-Deck Walking deck membrane FL 12407.1 Category/Subcategory Manufacturer Product Description Limitation of Use State 4. F F I1! py E.SHUTTERS 1.Accordion _ 2.Bahama 3.Storm panels Town and Country Industries Storm shutters N/A FL 11963 4.Colonial 5.Roll-up 6.Equipment 7.Other F.STRUCTURAL COMPONENTS 1.Wood connector/anchor Simpson Strong Tie Per engineering 2.Truss plates Alpine Engineered Truss plate conn. Per engineering 3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1 4.Railing 5.Coolers-freezers 6.Concrete admixtures 7.Material 8.Insulation forms 9.Plastics 10.Deck-roof 11.Wall 12.Sheds 13.Other G.SKYLIGHTS 1.Skylight Sun Tek FGC Skylite FL 2442 2.Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1 7/16"Zip Wall-Structural 1 OSB(roof and wall);manufacturered by Huber Engineered Woods 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector,a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the or�eqv F F I C L. COPY listed in this document must be approved by the Building Official. Audrey Regnier ii 1).42.7„,..._-__. (Contractor Name) (Print Name) (Signature) Company Name: Toll Brothers,Inc. Mailing Address: 160 Cape May Avenue City: Ponte Vedra State: FL Zip Code: 32081 Telephone Number: 904 217-0739 Fax Number: Cell Phone Number: 904-405-8969 Email Address: aregnierPtollbrothers.com Off1ECOPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: The Terrano Builder Name: McGowan's Heating&Air Con Street: Lot 85 Atlantic Beach CC Permit Office: Duval County City,State,Zip: Atlantic Beach,FL 32233 Permit Number. Owner. Toll Brothers,Inc. Jurisdiction: 281000 Design Location: FL,Jacksonville NAS County:y (Florida Climate Zone 2) 1.New construction or existing New(From Plans) 9. Wall types(3627 ft2) . Insulation Area(ft') 2.Single family or multiple family Single-Family a. Wood 2x6 Wad R19 R=19.0 3135.25 b. Wad 2x4 Adjacent To Garage R=13.0 491.55 3.Number of units,if multiple family 1 c. N/A R= 4.Number of bedrooms 4 d. N/A R= 10. Ceiling types(1789 ft2) Insulation Area(ft2) 5.Is this a worst case? No a. Shingles Vented Attic R3 R=21.0 1788.75 • 6.Conditioned floor area above grade(ft2) 3280.00 b. N/A R= Conditioned floor area below grade(ft2) 0 a N/A R= ryry�� • 7. Windows(435 ft2) Description Area(ftp 11.D a.Sup:Attic(Ret:Attic/AH:Main 6.0.00 • a.U-Factor. Dbl,U=0.340 434.53 b. SHGC: SHGC-0.27 b.U-Factor. 12.Cooling systems kBtu/hr Effidency SHGC: a.Spdt alrsource heat pump 47.0 SEER:14.5 • a U-Factor. SHGC: 13.Heating systems kBtu/hr Efficiency • d.U-Factor. a.Split air source heat pump 44.0 • HSPF:8.5 SHGC: " Area Weighted Average Overhang Depth: 3.964 ft 14.Hot water systems Area Weighted Average SHGC: 0.270. a.Propane instantaneous(0 gal) Cap:0 gal EF:0.92 8. Floor types(2377.50 ft2) Insulation Area(ft2) b.Conservatlon features a. Frame Floor Over Fxt R19 R=19.0 33.00 (None) b. Frame Floor Over Garage R11 R=11.0 172.50 C. Slab On Grade R=0.0 2172.00 15.Credits None Glass/Floor area: 0.132 Total Proposed Modified Loads: 69.04 PASS Total Baseline Loads: 78.03 • /''! 1 hereby certify that the plans and specifications covered by this Review of the plans and specifications ,,,- calculation are in compliance with the Florida Energy Code. covered by this calculation indicates ri'e : �14�-,:%. compliance with the Florida Energy "� + Code.Before construction is completed, / s!? PREPARED BY: ' ."1" this building will be inspected for " • �uyr ax .t / compliance with Section 553.908 a �)F t;Zi,i DATE: 1/2/18 / Florida Statutes. I hereby certify that this budding,as designed,is in compliance with •,: ' the Florida Energy Code. n, 0N'- OWNER/AGENTJ ' :10FF1c1. NG L: // i)r-- DATE: k I g.t-I I tr 2 y U/Q" -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1,1 and starting July 1, 2017,this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). - 41"vwel{pl'f7PaiOi E" 2018-Jan-021709:17 - "`"-'=z-'' PoghFStite®Universa1201818.0.08RS000000 Rigt#Erargy®Florida 2017 Section 405.4.1Comp9ariSoftware Paget ...rsWlcOowarfs H&A1Terrano 3164-Lot 85 ABCC.np Calc•MJB Frort Door faces:E FORM R405-2017 • Building Input Summary Report PROJECT Titre: The Terrano Bedrooms: 4 Address type: Street address Building Type: FLAsBuilt Bathrooms: 3 Lot4: Owner: Toll Brothers,Inc. Conditioned Area: 3280 Block/Subdivision: #of Units: 1 Total Stones: 1 Platbook: Builder Name: McGowan's Heating&Air Con Worst Case: No Street: Lot 85 Atlantic Beac Permit Office: Duval County Rotate Anle:, 0 County: Jurisdiction: 261000 Cross Venilation: No City,State,Zip: Atlantic Beach,FL 32233 Family Type: Single-Family Whole House Fan: No New/basting: New(From Plans) Terrain: Suburban Year Construct: 2018 Shielding: Suburban Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp •// Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range ✓/ FL,Jacksonville NAS FL Jackson1ile-Cr 2 37 96 70 75 995 46 Medium BLOCKS # Name Area Volume 1 Main 3280.00 ft' 33161.48 ft' SPACES # Area Volume Kitchen Occupants Bedrooms Inftl ID Finished Cooled Heated 1 Great 583.75 ft' 6596.38 ft' No 0 0 1 Yes Yes Yes 2 Dining 204.00 ft' 2305.20 ft' No 0 0 1 Yes Yes Yes 3 Foyer 165.00 ft' 1864.50 ft' No 0 0 1 Yes Yes Yes 4 Study 119.00 ft' 1344.70 ft' No 1 0 1 Yes Yes Yes 5 Bed 2 172.50 ft' 1552.50 ft' No 1 1 1 Yes Yes Yes - 6 Bed 3 208.00 ft' 1872.00 ft' No 1 1 1 Yes Yes Yes 7 Loft 388.00 ft' 3492.00 ft' No 0 0 1 Yes Yes Yes 8 MWIC 94.50 ft' 850.50 ft' No 0 0 1 Yes Yes Yes 9 Laundry 66.00 ft' 594.00 ft' No 0 0 1 Yes Yes Yes 10 Master Bed 286.75 ft' 2580.75 ft' No 2 1 1 Yes Yes Yes 11 Master Bath 168.00 ft' 1512.00 ft' No 0 0 1 Yes Yes Yes 12 AH 15.00 ft' 135.00 ft' No 0 0 1 Yes Yes Yes 13 Pantry 27.50 ft' 310.75 ft' No 0 0 1 Yes Yes Yes 14 Stairs 1 68.25 ft' 771.23 ft' No 0 0 1 Yes Yes Yes 115 Bonus 144.00 ft' 1296.00 ft' No 1 1 1 Yes Yes Yes 17 Bath 2 90.00 ft' 587.6011 . ft' No 0 0 1 Yes Yes Yes 18 Kitchen Break 363.75 ft' 4110.38 ft' Yes 0 0 1 Yes Yes Yes 19 Foyer-OTB 64.00 ft' 576.00 ft' No 0 0 1 Yes Yes Yes FLOORS ✓ # Floor Type Space Perimeter R-Value Area Tile Wood Carpet I., 1 Slab On Grade Great 53 ft 0 583.75 ft' 0 1.0 0 2 Slab On Grade Dining 29 .ft 0 204.00 ' 0 0 3 Slab On Grade Foyer 7 ft 0 165.00 ft' 0 . 0 4 Slab On Grade Study O ft 0 119.00 ft' 0 1.0 0 5 Frame Floor Over Garage R11 Bed 2 25 ft 0 157.50 ft' 0 1.0 0 6 Frame Floor Over Garage R11 Loft 0 ft 0 10.50 ft' 0 1.0 0 7 Frame Floor Over Ext R19 Master Bed 4 ft 0 33.00 ft' 0 1.0 0 8 Slab On Grade Pantry 0 ft 0 27.50 ft' 0 1.0 0 9 Slab On Grade Stairs 1 O ft 0 68.25 ft' 0 1.0 0 10 Slab On Grade Bath 2 0 ft 0 52.00 ft' 0 1.0 0 11 Frame Floor Over Garage R11 Bath 3 1 ft 0 4.50 ft' 0 1.0 0 12 Slab On Grade Kitchen_Break 44 ft 0 363.75 ft' 0 1.0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1/ 1 Hip RoofAsph 1938 ft' Dark 0.75 No 0.90 No 17 23 2 Hip RoofAsph 451 ft' Dark 0.75 No 0.90 No 17 23 M +NF i1orrigr'irrm" 2018-Jan-0217:09:17 „,.- - .,-°•"-- Poght-Sute®Universal 201818.0.08RS000000 Right-Energy®Florida 2017 Seclion405.4.1 Compliant Software Page 3 ...rs\McGowarisH&A\Terraro3164-Lot 85ABCC.np Calc=MJB Front Door faces:E FORM R405-2017 ATTIC 71Type Ventilation Vent Ratio(1 in) Area RBS IRCC Full attic Vented 300 1788.75 ft' RN N 2 FuR attic Vented 300 416.25 ft' N N CEILING ./7# Ceiling Type Space R-Value Area Framing Fraction Truss Type / 1 Shingles Vented Attic R3 Dining 38 92.00 ft' 0.10 Wood 2 Shingles Vented Attic R3 Bed 2 38 172.50 ft' 0.10 Wood 11\l/ 3 Shingles Vented Attic R3 Bed 3 38 208.00 ft' 0.10 Wood 4 Shingles Vented Attic R3 Loft 38 388.00 ft' 0.10 Wood , 5 Shingles Vented Attic R3 MWIC 38 94.50 ft' 0.10 Wood 6 hingles Vented Attic R3 Laundry 38 66.00 ft' 0.10 Wood 7 thrin9gles Vented Attic R3 Master Bed 38 286.75 ft' 8 Shingles Vented Attic R3 Master Bath 38 168.00 ft' 0.10 Wood 9 • Shingles Vented Attic R3 AH • 38 15.00 ft' 0.10 Wood 10 gSghhhiiingles Vented Attic R3 Bonus 38 144.00 ft' 0.10 Wood Shingles Vented Attic R3 Foyer OTB 38 90.00. ft' 0.10 Wood WALLS t ✓ # pmt Adjacent To Wall Type Space Cavity Va ty Width HeighttArea Sheathing Framing SolarAbsor. Below YP P R-Value Fraction Grade% j1 N Exterior Wood 2x6 Wa Great 19 25 6 11 4 288.1 ft' 0 0.25 0.606 0 2 W Exterior Wood 2x6 Wa Great 19 27 0 11 4 305.1 ft' 0 0.25 0.20 0 3 - Partition Wall 2x4 Ad Great 13 4 0 1 4 452 ft' 0 0.22 ' 4 E Exterior Wood 2x6 Wa Dining 19 12 0 11 4 135.6 ft1 0 0.25 0.60 0 5 S Exterior Wood 2x6 Wa Dining 19 17 0 11 4 192.1 ft2 0 0.25 0.60 0 6 E Exterior Wood 2x6 Wa Foyer 19 7 0 11 4 79.1 ft2 0 0.25 0.60 0 7 Partition Wall 2x4Ad Foyer 13 8 6 11 4 96.1 ft2 0 0.22 0.20 0 8Partition Wal2x4Ad Study13 22 6 11 -4 254.3 '00 0.22 0.20 0 9 N Exterior Wood 2x6 Wa Bed 19 14 6 9 0 130.5 ft2 0 0.25 0.60 0 10 E Exterior Wood 2x6 Wa Bed 2 19 13 0 9 0 117.0 ft' 0 0.25 0.60 0 11 N Exterior Wood 2x6 Wa Bed 3 19 16 0 9 0 144.0 ft' 0 0.25 0.60 0 12 W Exterior Wood 2x6 Wa Bed 3 19 13 0 9 0 117.0 ft' 0 0.252 0.60 0 13 error Woo Z Wa Loft 19 7 0 9 0 63.0 ft' 0 0.25 0 60 0 4 W Exterior Wood 2x6Wa MWIC 9 9 0 9 0 81.0 ft' 15 N Exterior Wood 2x6 Wa Master Bed 19 3 0 9 0 27.0 ft' 0 0.25 0.60 0 16 S Exterior Wood 2x6 Wa Master Bed 19 17 6 9 0 157.5 ft' 0 0.25 0.60 0 17 W Exterior Wood 2x6 Wa Master Bed 19 17 6 9 0 157.5 ft' 0 0.25 0.60 0 18 S Exterior Wood 2x6 Wa Master Bath 19 14 0 9 0 126.0 ft' 0 0.25 0.60 0 19 E Exterior Wood 2x6 Wa Bonus 19 11 6 9 0 103.5 ft' 0 0.25 0.60 0 20 S Exterior Wood 2x6 Wa Bonus 19 12 0 9 0 108.0 ft' 0 0.25 0.60 0 21 - Partition Wal 2x4 Ad Bath 2 13 8 6 11 4 96.1 ft' 0 0.22 0.20 0 22 N Exterior Wood 2x6 Wa Bath 3 19 10 0 9 0 90.0 ft' 0 0.25 0.60 0 23 S Exterior Wood 2x6 Wa Kitchen Break 19 31 61 4 356.0 ft' 0 0.25 0.60 0 24 W Exterior Wood 2x6 Wa Kitchen Break 19 12 6 11 4 141.3 ft2 0 0.25 0.60 0 25 N Exterior Wood 2x6 Wa Foyer-OTB 19 8 0 9 0 72.0 ft' 0 0.25 0.60 0 26 E Exterior Wood 2x6 Wa Foyer OTB 19 8 0 9 0 72.0 ft' 0 0.25 0.60 0 27 S Exterior Wood 2x6 Wa Foyer OTB 19 8 0 9 0 72.0 ft2 0 0.25 0.60 0 DOORS Width Height ✓ # Omt Door Toe Space Storms IJ--Value Ft In Ft -In Area ( 1 E Door,mtl fbrgl type Foyer None 0.600 3 0 8 0 24.0 ft' 2018-Jao-021709:17 M�f`-"--'--"-LW�CF1�- RIght Siile®Uriversa1201818.0.08 RSU00000 Right-Energy®Florida 2017 Section 405.4.1 Complier&Software Page4 \ in n ..ss\McGowarfs H&ATerra3184•Lot 85 ABCC. p Calc=MJ8 Frort Door faces:E FORM R405-2017 WINDOWS ✓ # Omt WallIFrame Panes NFRC U-Factor SHGC Storms Area Depth Separation Siad r Screening 1 N . 1 Vinyl Low-E Double Yes 0.340 0.27 No 3.0ft' 1 ft 0 In 11 ft 0 in None None 2 W Vn ow�EE Doubb a Yes 0.340 0.27 No 36.0ft' 8 ft 0 In 6 in None outdoor 3 W Vin i ow E Doub�a Yes 0.340 0.27 No 96.0ft' 8 ft 0 In 1 ft 6 in None outdoor , 4 E 4 Vinyl Low-E Double Yes 0.340 0.27 No 36.0ft' 1 ft 0 in 1 ft 6 in None outdoor 5 E 6 Vinyl Low-E Double Yes 0.340 0.27 No 16.0ft' 8 ft 0 in 1 ft 6 in None None 6 N 9 Vinyl Low-E Double Yes 0.340 0.27 No 15.0ft' 1 ft 0 in 1 ft 6 in Blinds 45° outdoor . 7 E 10 VinylLow-E Double Yes 0.310 0.27 No 'f2.0ft' 4'8 0'n 1 ft 6 in Blinds 45° outdoor . 8 N 11 vinyl Low-E Double Yes 0.340 0.27 No . I S.Oft' ft 0�n 1 ft 6 in Blinds 45° outdoor 9 W 12 Vinyl Low-E Double Yes 0.340 0.27 .No 24.0ft' 1 ft 0 In 1 ft 6 in Blinds 45° outdoor 10 E 13 Vinyl Low-E Double Yes 0.340 0.27 No 12.0ft' 1 ft 0 in 1 ft 6 in None outdoor 11 W 14 Vinyl Low-E Double Yes 0.340 0.27 No 4.5ft' 1 ft 0 In 1 ft 6 in None outdoor 12 S 16 Vinyl Low-E Double Yes 0.340 0.27 No 9.0ft' 1 ft 0 in 1 ft 6 in None outdoor 3 W 1177 Vn Low=Doub a Yes 0.34 27 0 30.pft' �t n 1 ft g n g d d 4 S 18 VIny Low-=Doub�e Yes 0.345 8.27 No 24.Oft' 1 tt 8�n 1 tt 8 In Blinds 45° outdoor 15 E 19 Vinyl Low-E Double Yes 0.340 0.27 No 6.0 ft' 1 ft 0 In 1 ft 6 in None outdoor 16 S 20 Vinyl Low-E Double Yes 0.340 0.27 No 15.Oft' 1 ft 0 in 1 ft 6 to Blinds 45° outdoor 17 N 22 Vinyl Low E Double Yes 0.340 0.27 No 6.0ft' 1 ft 0 in 1 ft 6 In Blinds 45° outdoor 18 S 23 V' yl Low E Double Yes 0.340 0.27 No 24.0ft' 1 ft 0 In 11 ft 0 In None outdoor 19 W 24 V ny Low-E Double Yes 0.340 0.27 No 36.0ft' 8 ft 0 in 1 ft 6 in None outdoor 20 E 26 Vinyl Low-E Double Yes 0.340 0.27 No 15.0ft' 1 ft 0 In 1 ft 6 in None None GARAGE ✓/# FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation ✓ 1 589 ft' 589 ft' 69 ft 11 ft 19 INFILTRATION - • • # Scope Method SLA CFM 50 ELA EdLA ACH ACH 50 1 Wholehouse Blower Door 0.000386 3316 182.4 342.5 0.56 6.00 HEATING SYSTEM 7 # System Type Subtype Efficiency Capacity Block Ducts 1 Split air source heat pump HSPF:8.5 44.0 kBtu/hr 1 sys#1 COOLING SYSTEM . ✓/ # System Type Subtype Efficiency Capacity Air Flow, SHR Block Ducts I 1 Split air source heat pump SEER:14.5 47.0 kBtu/hr 1774 cfm 0.80 1 sys#1 HOT WATER SYSTEM ✓ # System Type Subtype Location EF Cap Use SetPnt Conservation / 1 Propane Instantaneous 0.92 0 gal 70 gal 120°F None ►yDUCTS ✓• # Location Sup* Area LocaReturn Area Leakage Type Handler CFM 25 Percent HVAC# 9 YP Out Leakage ON RLF Heat Cool 1 Attic 6.0 449 ft' Attic 114 ft' oder + (Default) 6.00 1 1 TEMPERATURES Programable Thermostat: Ceiling Fans: Cooling ( X )Jan [ Xi Feb [ X1 Mar [ XI Apr I X] May [ X] Jun [ X] Jul [ X1 Aug [ X] Sep [ X] Od [ X) Nov [ X] Dec Heating [[ X 1]Jan [[ X)] Feb [[ X 1] Mar [[ X]] Apr X]] May [[ X)] Jun [[ X 1] Jul [[ X 1] Aug [[ X 1] Sep [[ X 1] Oct [f X 1] Nov E X 1] Dec Venting X Jan X Feb X Mar X Apr X May X Jun X Jul X Aug X Sep X Oct X Nov X Dec Thermostat Schedule: Florida Building Code,6th Edition Hours Schedule Type (P017) 1 2 3 4 5 6 7 8 7g9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 •75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 7 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 '114" MiifNa�hf A7A#51rC" 2018-Jan-0217:09'17 Right-Site5)Urversa1201818.0.08RS000000 Right-Energy®Florida 2017 SedJon405.4.1Compliant Software Pages ...rsWlcGowarfs HSA\Terrane 3184-Lot 85 ABCC.np Calc=MJ8 Front Door faces:E FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ES oe` g � PERFORMANCE tm $$ Ihe twrviee tnerwermnceIINDEX hoe. Lot 85 Atlantic Beach CC,Atlantic Beach, FL 32233 1.New construction or existing New(From Plans) 9.Wall Types Insulation Area(ft2) 2.Single family or multiple family Single-Family a. Wood 2x6 Wal R19 R=19.0 3135.25 3.Number of units,if multiple family 1 b. Wall 2x4 Adjacent To Garage R=13.0 491.55 a N/A R= 4.Number of bedrooms 4 d. N/A R= 5.Is this a worst case? No 10.Ceiling Types Insulation Area RI 6.Conditioned floor area(ft" 3280.00 a. Shingles Vented Attic R3 R=21.0 1788.75 b. N/A R= 7.Windows" Description Area(ftp c. N/A R= a.U-Factor. Dbl,U=0.340 434.53 SHGC: SHGC=0.27 11.Ducts R Area(ftt) b.U-Factor. a.Sup:Attic/Ret:AttIc/AH:Main 6.0 0.00 SHGC: c.U-Factor. SHGC: 12.Cooling systems kBtu/hr Effidency d.U-Factor. a.Split air source heat pump 47.0 SEER:14.5 SHGC: b. Area Weighted Average Overhang Depth: 3.964 ft Area Weighted Average SHGC: 0.270 13.Heating systems kBtu/hr Efficiency a.Spliit air source heat pump 44.0 HSPF:8.5 b. 8.Floor Types Insulation Area(ft') 14.Hot water systems a. Frame Floor Over Ext R19 R=19.0 33.00 a.Propane instantaneous(0 gal) Cap:0 gal b. Frame Floor Over Garage R11 R=11.0 172.50 EF:0.92 c. Slab On Grade R=0.0 2172.00 b.Conservation features (None) 15.Credits None I certify that this home complied with the Florida Energy Efficiency Code for Building Construction through the above energysavingfeatures which will be installed or exceeded)in this home before 0.' � ,, .,4 final inspection. Otherwise,a new EPL Display Card will be completed based on installed Code ' .i, ' ': compliant features. ' ,=r-0r`It�, • Builder Signature: / f �! Date: 1/o)(l/I 0 f WI .. L ' '. t Address of New Home:1.140/L-1Ic -;c_13RPt City/FL Zip:,J-( 4- c_ ".� ?4e,,,. w''� **Label required by Section 303.1.3 of the Florida Building Code,Energy Conservation,if not DEFAULT. "tildt, wrtelri Poorit- 2018-Jan-0217:09:17 - w4 Right-SLite®Universal 201818.0.08RS000000 RIgH•Energy®Florida 2017 Sedan 405A.1 Compliant Software Page ...rsfMcGowar s H&A1Terra,o 3184-Lot 85 ABCC.rtp Cato=MJ8 Front Door faces:E FORM R405-2017 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Lot 85 Atlantic Bach CO PERMIT#: Atlantic each,(--L 32233 MANDATORY REQUIREMENTS -See individual code sections for full details. SECTION R401 GENERAL R401.2 Projects shall comply with one of the following: 2.Section R405 and the provissions of Section R401 through R404 labeled"Mandatory". R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be Installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. Awritten report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: . . . .1.Exterior windows and doors,fireplace and stove doom shall be closed,but not sealed,beyond the intended ._ __ weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if Installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. • R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127,the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry fireptaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMAANDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 1h rigotl7i'l-Y7et``I.:"' 2018-Jan-0217:09:17 Rigt-Sute8iUniversal 201818.0.08RSU00000 Right-Energytt Florida 2017 Sedion405.4.1Compliant Software Page 7 ...rswlcGowan'sH&A\Terram3184-Lot 85ABCC.np Cato=MJB Front Door faces:E FORM R405-2017' MANDATORY REQUIREMENTS -(Continued) R402.4.4 Rooms containing fuel-burning appliances In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement. The door Into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be Insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1.Direct vent apilances with both intake and exhaust pipes installed continuous to the outside. 2.Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls SECTION R403 SYSTEMS R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except dunng defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory). All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by ether individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler endosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Awritten report of the results of the test shall be signed by the party conducting the test and provided to the code official. . R403.3.5 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be dedicated return pipe ora cold water supply pipe. Gravity and themlosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and • when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. r - 'w�'dtzl l�77117+3►�'7%" 2018-Jan-0217:09:17 = Right-Stile®Universal 201818.0.08RS000000 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 8 ...rsWlcGowarisH&A1Terrano3164-Lot 85ABCC.rtp Calc=MJ8 Front Door facen:E FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1 Storage water heater temperature controls. R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the Intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 shut down. A separate switch or a dearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water heating systems to be turned off. R403.5.6.2 Water heating equipment Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water heating system. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar • water-heating systems should meet the following criteria: 1. Be Installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation,including: Natural,Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that dose when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where mechanical ventilation fans are Integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shall meet • the following criteria: 1.The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation forAcceptable IndoorAir Quality,shall be the maximum rates allowed for residential applications. 2.No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3.If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved methodologies,heating and cooling calculation based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY(a) AIRFLOW RATE MAXIMUM CFM CFMNVATT CFM Range hoods Any 2.8 cfrn/watt Any In-line fan Any 2.8 tin I/watt Any Bathroom,utility room 10 1.4 ufiti/watt <90 Bathroom,utility room 90 2.8 cirri/Watt Any For SI:1 efrrt-28.3 L/min. (a)When tested in accordance HVI Standard 916 ^41' O j1.e'a C-4lC^ 2018-Jan-02 17:09:17 _- -- Right-Sute®Universa1201818.0.08RS000000 Right-Energ4Flonda2017 Section 405.4.1Compliant Software Page9 ...rs1McGowarts H&A\Terrano 3184-Lot 85 ABCC.np Calc=MJ8 Front Door faces:E MANDATORY REQUIREMENTS -(Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the dosest available size provided by the manufacturers product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value forAHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturers expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1.Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2.When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1 R403.7.1.2.3 Fossil fuel heating equipment The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an Intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1.A separate cooling or heating system Is utilized to provide cooling or heating to the major entertainment areas. 2.A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commerdaf Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory). Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1.Where public health standards require 24-hour pump operations. 2.Pumps that operate solar-and waste-heat-recovery pool heating systems. 3.Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or afterApril 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2018-Jan-02 17:09:17 RIght-Sures Universal 2018 18.0.08 RS000000 Rigid-Er orgy®Florida 2017 Sed on405.4.1 Compliant Software Page 10 ...rswlcGowan's HBA\Terrano 3164-Lot 85 ABCc.rty Calc=MJ8 Front Door faces:E MANDATORY REQUIREMENTS-(Continued) R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low AirTemperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatory). The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception: Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 2018-Jan-0217:09:17 ---- Right-Site®Universal 201818.0.08RS000000 Right-Energy®Florida 2017 Section405.4.1 Compliant Software Page 11 ...rs1McGowaris H&A\Terraro 3164-Lot 85 ABCC.np Calc=MJ8 Frort Door faces:E FORM R405-2017 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: The Terrano Builder Name McGowan's Heating&Air Con Street: Lot 85 Atlantic Beach CC Permit Office: Duval County City,State,Zip: Atlantic Beach,FL 32233 Permit Number Owner. Toll Brothers,Inc. Jurisdiction: 261000 Design Location: FL,Jacksonville NAS COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the requirements contains envelope.The exterior thermal envelope sealing material. contains a continuous barrier.Breaks or joints in the air barrier shall be sealed. permeable mreable insulation shall not be used as a Ceiling/attic The air barrier in any dropped ceiling/soffit The insulation in any dropped ceiling/soffit shall be aligned with the insulation and any shall be aligned with the air barrier. gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attics paces shall be sealed. Walls The junction of the foundation and sill plate Cavities with corners and headers of frame walls / . shall be sealed.The junction of the top plate shall be insulated by completely filling the cavity and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Windows,skylights The space between window/door jambs and framing, and doors and skylights and framing shall be sealed. // Rim joists are insulated and include an air Rim joists shall be insulated. Rim joists barrier. / Floors(including The air barrier shall be installed at any exposed Floor framing cavity Insulation shall be installed 1 above-garage and edge of insulation. to maintain permanent contact with the underside cantilevered floors) of subfloor decking,or floor framing cavity `// Insulation shall be permitted to be in contact with the top sideof sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space Exposed earth in unvented crawl spaces shall be Where provided in lieu of floor insulation, walls covered with a Class I vapor retarder with insulation shall be permanently attached //: overlapping joints taped. to the crawlspace walls. - Shafts,penetrations Duct shafts,utility penetrations,and flue shaft JJ openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts In narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage Air sealing shall be provided between the garage separation and conditioned spaces. N.7/7 Recessed Recessed light fixtures installed In the building Recessed light fixtures installed in the lighting thermal envelope shall be sealed to the drywall. building thermal envelope shall be air tight and IC rated. Plumbing and Batt Insulation shall be cut neatly to fit around wiring wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on The air barrier shall be installed behind Exterior walls adjacent to showers and tubs ., exterior wall electrical or communication boxes or air-sealed shall be insulated. boxes shall be installed, Electrical/phone The air barrier shall be installed behind //: box on exterior electrical or communication boxes or air-sealed walls boxes shall be installed. HVAC register HVAC register boots that penetrate building boots thermal envelope shall be sealed to the subfloor or drywall. Concealed When required to be sealed,concealed fire / i sprinklers sprinklers shall only be sealed in a manner that J Is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition,inspection of log walls shall be in accordance with the provisions o`ICC-400. wirigaittii.'p.:ottu" 2018-Jan-02 17:09:17 Right-Suite®Unversal 201818.0.08RS000000 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 12 ...rslMcGowarisH&A\Terrano3164-Lot 85ABCC.rtp Calc=MJB Front Door faces:E FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Methods Pro'ect Name: The Terr no. uild?r me: U1cG 'vyan's Heating&Air Con �e. tat 85 Atlantl Bach CC . ermit niic Duval County t te,Z a tic Beac hL 3 233 erm t Numeber. e ign oca on: Jac�ksonut le NA� Junsdiction: 261000 Cond.F oorkea: 32$0 ft Cond.Volume: 33161 ft3 . Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: Singie or Multi Point Test Data: _ Required ACH(50)from _HC�l,JSEPRESSURE FLOW FORM R405-2017: 1 Pa cam. 2 Pa aril Tested ACH(50)*: 3 Pa cfm 4 Pa cfm *Tested leakage must be less than or equal to the required ACH(50)shown on Form R405-2017 for this building. If the 5 Pa (Jul tested ACH(50)is less than 3,the building must have a 6 Pa cfm mechanical ventilation system. 402.4.1.2 Testing option. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. Awritten report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: ' 1.Exterior windows and doors,fireplace and stove doors shall be dosed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall he open; 4.Exterior doors forcontinuous ventilation systems and heat recovery ventilators shall be dosed and sealed; 5.Heating and cooling systems if installed at the time of the test, shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I herby certify that the above envelope leakage Testing shall be conducted by either0%,1-04.5.7.` performance results demonstrate compliance with individuals as defined in Section a"f CINw.otioi ,„t''w Florida Energy Code requirements in accordance 553.993(5)or(7),Florida Statutes ,� •'r 0 6._,� ctrl` : with Section R402.4.12. or individuals licensed as set forth A. wy, ,..1(;,,•14.. rz in Section 489.105(3)(f) (g),or(i)or � —.,_,L, ' an approved third party.Awritten f. -1,I;.M = A.t report of the results of the test shall \-*7:.' w / ,1, Signature: be signed by the party conducting -q`C the test and provided to the code '•i•• �rti . Printed Name: official. DATE: BUILDING OFFICIAL: DATE: "Iii ' +rw:tigerL*a7u?1-1:- 2018-Jan-0217:09:17 °� - Righ-SuteeUniversal 201818.0.08RS000000 Rig ht-EnergyaFlorida 2017 Sedan 405.4.1 Compliant Software Page 13 ...rsMcGowan'sH&A1Terrar 3164-Lot 85 ABCC.rupCal c=MJ8 Frort Door faces:E 4 wrightsoft Project Summary Job: Lot 69 ABCC Main By. Saldie Guintivano McGowan's Heating&Air Conditioning, Inc. 11320 E.Philips Parkway Dr.,Jacksoville,FL 322556 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowarsac.com Web:www.mcgowartsac.com Project Information For: Toll Brothers,Inc. Lot 85 Atlantic Beach CC,Atlantic Beach,FL 32233 Phone:(904)217-0739 Fax:(904)814-8173 Web:www.tollbrothers.com Email:smerten@tollbrothersinc.com Notes: The Terrano Desi•n Information Weather: Jacksonville NAS,FL,US Winter Design Conditions Summer Design Conditions Outside db 37 °F Outside db 96 °F Inside db 70 °F Inside db 75 °F Design TD 33 °F Design TD 21 °F Daily range M Relative humidity 50 % Moisture difference 46 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29905 Btuh Structure 26875 Btuh Ducts 2066 Btuh Ducts 5069 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31971 Btuh Use manufacturer's data y Rate/swingmultiplier 1.00 Infiltration Equipmensensibleload 36470 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3( artial)/2 Pressure/AVF 50 Pa 3592 cfrn Structure 7215 Btuh Ducts 903 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 3164 3164 Equipment latent load 8119 Btuh Volume(ft3) 33161 33161 Air changes/hour 0.56 0.35 Equipment Total Load(Sen+Lat) 44589 Btuh Equiv.AVF(cfm) 312 192 Req.total capacity at 0.80 SHR 3.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0480000A0 Cond CH14NB0480000A0 AHRI ref 9162971 Coil FB4CNP061 L AHRI ref 9162971 Efficiency 8.5 HSPF Efficiency 12.0 EER,14.5 SEER Heating input Sensible cooling 37600 Btuh Heating output 44000 Btuh @ 47°F Latent cooling 9400 Btuh Temperature rise 0 °F Total cooling 47000 Btuh Actual airflow 0 cfm Actual airflow 1774 cfrn Air flow factor 0 cfmA3tuh Air flow factor 0.056 cfrn/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.80 Capacity balance point=29°F Backup:Carrier Input=10 kW, Output=34121 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 'T wrlghtsoft- 2018-Jan-02 17:26:17 ,,LY. -k - , --, Right-Sute®Lkiversal 2018 18.0.08 RSU00000 Page 1 �[✓" ...rsfMcGowaris H8A1Terrano 3164-Lot 85 ABCCnp Calc=MJ8 Front Door faces:E - - wrightsoft Manual S Compliance Report D Lot69ABCC Main By. Saldie Guintivano McGowan's Heating &Air Conditioning, Inc. 11320 E.Philips Parkway Dr.,Jacksoville,FL 322556 Phone:904-278-0339 Fax:904-278-0366 Email:saldietmcgowansac.com Web:vww.mcgowarsac.com Project Information For: Toll Brothers,Inc. Lot 85 Atlantic Beach CC,Atlantic Beach,FL 32233 Phone:(904)217-0739 Fax:(904)814-8173 Web:www.tollbrothers.com Email:smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 95.7°F Sensible gain: 36470 Btuh Entering coil DB: 75.9°F Outdoor design WB: 77.1°F Latent gain: 8119 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 44589 Btuh Indoor RH: 50% Estimated airflow: 1774 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0480000A0+FB4CNP061L Actual airflow: 1774 cfm Sensible capacity: 37063 Btuh 102%of load Latent capacity: 8249 Btuh 102%of load Total capacity: 45312 Btuh 102%of load SHR: 82% Heating Equipment Design Conditions Outdoor design DB: 36.8°F Heat loss: 33132 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: CH14NB0480000A0+FB4CNP061 L Actual airflow: 0 cfm Output capacity: 37292 Btuh 113%of load Capacity balance: 29 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Carrier Model: Actual airflow: 0 cfm Output capacity: 10.0 kW 103%of load Temp.rise: 20 °F Meets all requirements ofACCA Manual S. wf Ightso 2018-Jan-0217:26:17 Right-Sala/Uriversal 2018 18.0.08 RS000000 Page 1 ...rsMcGowaris H&A\Terrarn 3164-Lot 85 ABCC.n4 Calc=MJ8 Front Door faces:E - - wrightsoft Duct System Summary J Lot69ABCC Main By. Saldie Guintivano McGowan's Heating&Air Conditioning, Inc. 11320 E.Philips Parkway Dr.,Jacksoville,FL 322556 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowarsac.com Web:www.mcgowarsac.com Project Information For: Toll Brothers,Inc. Lot 85 Atlantic Beach CC,Atlantic Beach,FL 32233 Phone:(904)217-0739 Fax:(904)814-8173 Web:www.tollbrothers.com Email:smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.18 in H2O 0.24 in H2O Available static pressure 0.32 in H2O 0.26 in H2O Supply/return available pressure 0.198/0.122 in H2O 0.161/0.099 in H2O Lowest friction rate 0.146 in/100ft 0.119 in/100ft Actual airflow 0 cfm 1774 cfm Total effective length(TEL) 219 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Mali Ln(ft) Ln(ft) Trunk Bath2 c 127 0 7 0.344 4.0 Ox 0 VIFx 35.5 11.3 st2 Bath3 c 583 0 32 0.206 4.0 Ox 0 V1Fx 47.7 30.5 st3 Bed 2 c 2134 0 119 0.176 7.0 Ox 0 VIFx 43.0 48.8 st5 Bed 3 c 2991 0 166 0.230 8.0 Ox 0 V1Fx 35.7 34.5 st3 Bons c 1777 0 99 0.185 6.0 Oxo V1Fx 36.0 51.0 st5 Diring c 2058 0 114 0.136 7.0 Ox 0 VIFx 68.5 49.8 st7 Foyer OTB c 1632 0 91 0.179 6.0 Ox 0 VIFx 40.5 49.8 st5 Foyer-A c 1034 0 57 0.156 5.0 Ox 0 VIFx 65.5 37.6 st6 Great c 3461 0 192 0.316 8.0 Ox 0 VIFx 29.0 22.0 st2 Great-A c 3461 0 192 0261 8.0 Ox 0 VIFx 37.5 24.3 st2 Kitchen Break c 1822 0 101 0.135 7.0 Ox 0 VIFx 72.0 47.5 st7 Kitchen Break-A c 1822 0 101 0.119 7.0 Ox 0 VIFx 86.5 49.3 st7 Laundry-A c 807 0 45 0.246 5.0 Ox 0 VIFx 37.1 28.3 st3 Loft c 1525 0 85 0.199 6.0 Ox 0 VIFx 34.2 46.8 st5 MWIC-A c 743 0 41 0.245 4.0 Oxo VIFx 32.8 33.0 st3 Master Bath c 1121 0 62 0.336 5.0 Ox 0 V1Fx 14.7 33.4 st4 Master Bed C 2008 0 112 0.286 6.0 Ox 0 VIFx 17.8 38.6 st4 Master Bed-A C 2008 0 112 0.312 6.0 Ox 0 VIFx 14.1 37.7 st4 Paltry c 1 0 0 0.153 4.0 Ox 0 VIFx 69.0 36.4 st7 Study c 828 0 46 0.185 5.0 Ox 0 VIFx 55.0 31.9 st6 wrightsoft- 2018-Jan-02 17:26:17 Right-Sute®1Jriversa1201818.0.08RSW0000 Page 1 AAA ...rs\McGowaris H&A\Terrano 3164-Lot 85 ABCC.np Calc=MJ8 Front Door faces:E B:saoei JOoa UOJJ bfri=oleo &u 8V 48141-49L8 oueual\VW spemoJ3NAsr• N•o Zabed 00000r1St190'0'8Lgum wenn®alnS-lyBia ••,,.:.>.,__ . - '` 'No LL 9Z LL ZO-uef-9LOZ `1JO544.1E71JM MAAWV\ 0 X 0 0'81. ZL9 611'0 L811 0 IAVlead 11-1 1.p xldlu\ 0 x 0 0'91. 17179 061'0 69L 0 1AV>lead 17P 1.1a xldlun 0 x 0 O'Z1. 9179 611'0 8217 0 d/\b')leed £P )lunwl leualeW (u!) (u!) (wdl) 21d (4 3) (LW) adA1 aweN lona M x H weld 3013A u6!saa 610 61H Nuful algal I!alaa lunaj uan;aa 17P xdV\ 0 x0 0'Z I. 199 189'0 O'L1. Z£17 0 0x0 9:11 1711 xdV\ 0 x0 0'01. 669 061'0 1.'Z9 LZ£ 0 0x0 VW £J xdV\ 0 x0 0'8 9L17 £Z 1'0 £'08 991 0 0x0 941 £lJ xdV\ 0 x0 0'8 1117 6W0 £'£8 trot 0 0x0 1.41 xdV\ 0 x0 0'171 6179 081'0 6'179 L89 0 0x0 641 CP xdV\ 0 x0 0'L £1717 1Z 1'0 9'18 611. 0 0x0 Z41 Aum' new (u!)6u!ued0 (u!) (u!) (wdl) lid (8) (wP) (u.yo) (u!)az!s aweN pna ts!of/Pnis M x H we!o Dolan u6!saa 131 610 661-1 aIWO eigej Ilalaa goueae uan}aa xldluI\ 0 x 0 0'91 189 611'0 Z1.8 0 dAVNleed as xldlun 0 x 0 0'91 689 9L1.'0 Z96 0 dAV Need 11s 1ls xldlun 0 x 0 0'171 17£9 9L1'0 8L9 0 dAV>lead 171s vis xldlun 0 x 0 0'Z1 009 9L1'0 £6£ 0 dnyNeed 91s las xldlun 0 x 0 0'01. ZZ9 90Z'0 98Z 0 dA` )leed Cls as xldluI\ 0 x 0 O'Z1. 9£9 611'0 NV 0 dA`d)leed 91s 91s xldlul\ 0 x 0 0'01. 189 611'0 L1£ 0 dAV>lead Lls Aural leualeW (u!) (u!) (wdl) lid (wlo) (wp) adAi aweN lona M x H we!a Dolan u6!saa 610 61H WW1. mei Ile}ea junaj AIddns Static Pressure and Friction Rate Job: Lot 69ABCC wrightsoft Date: Main By. Saldie Guintivano McGowan's Heating &Air Conditioning, Inc. 11320 E.Philips Parkway Dr.,Jacksoville,FL 322556 Ptnne:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowarsac.com Project Information For: Toll Brothers,Inc. Lot 85 Atlantic Beach CC,Atlantic Beach,FL 32233 Phone:(904)217-0739 Fax:(904)814-8173 Web:www.tollbrothers.com Email:smerten@toll brothersinc.com Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0 0.06 Heat exchanger 0 0 Supply diffusers 0.05 0.05 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.32 0.26 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 22 19 Measured length of trunk 65 10 Equivalent length of fittings 49 55 Total length 136 83 Total effective length 219 Friction Rate Heating Cooling (i n/100ft) (i n/100ft) Supply Ducts 0.146 OK 0.119 OK Return Ducts 0.146 OK 0.119 OK Fitting Equivalent Length Details Supply 11C=40,4AD�0,11 G=5,11G=5,11C=40,11C=40,111=10,11G=5,11G=5,1A=35,11G=5,VelAdj=201:TotalEL=49 Return 6L=20,11C=40,11G=5,11C=40,11G=5,5E2=35,VelAdj=-90:Total EL=55 wrlgflt5Oft� 2018-Jan-02 17:26:17 - .•--- Right-StiteeUriversal 2018 18.0.08 RSU00000 Page 1 Cak ..rs\McGowaris 14&A\Terrar o 3164-Lot 85 ABCC.np Calc=MJ8 Front Door faces:E b41 11k N First Floor • 041'4" Kitchen_Break' 12x6 Great 07" 10 00 16x16 14x6 14x6 00 014" 08" 08" T 3"Fan(I 8 x4 T 12x6 Stairs 1 Bat 2 9 (34" 1I Pantry 10x6 - 012" s. 05" I t1 Irwwwwwwween- 8x4 04' 12x6 a w"J Study 07" 12x12 12x12 Dining 10x6 05" Foyer -- Garage Job#: Lot 69 ABCCMcGowan`s Heating&Air Conditioning,Inc. Scale: 1 :89 Performed by Saldie Guintivano for: Page 1 Toll Brothers,Inc. 11320 E. Phillips Parkway Dr. Right-Suite®Universal 2018 Lot 85Atlantic Beach CC Jadcsoville, FL 322556 t s.0.o817 2 02 Atlantic Beach,FL 32233 Phone: 904-278-0339 Fax:904-278-0366 2018-Jan-02 ot85A5 Phone:(904)217-0739 Fax(904)814-8173 wnnnrmcgowansac.com saldie@mcgowansac.com A�Tertano3lsa-LotaSABCGnp wwtollbrothers.com smerten@tollbrothersinc.com Second Floor II MVVIC Master Bed 010" 14 x6 8 x4 14 x 14 attic,, _ d 3 10x6 010" 06" ■ 10x6 . 016" . �i� y ll 06" 12 x 12 3"Fan yo , Sup Riser RJ VW 18x18gill 6 Laund NMI \/ 10x6 016" 05 x4 Fill 10x10 J 8 8 x4 08" J / 10 x10 012" 04 3"Fan pir, 018" 012" \Ret Riser 014" VW Master Bath NE 0 6x10 3"Fan 06' wh Loft 12x12 . ill 12 x12 08" 4 Bed 2 Bonus I 6x10IL.: '' 06" 10x6 06" Foyer OTB Job#: Lot 69 ABCCMcGowan's Heating&Air Conditioning,Inc. Scale: 1 :89 Performed by Saldie Guintivano for: Page 2 Toll Brothers,Inc. 11320 E. Phillips Parkway Dr. RightSuite®Universal 2018 Lot 85Atlantic Beach CC Jacksoville, FL 322556 2018-Jan-02.02 18.0.08 17 26:25 .. 00 -02 17:2 Atlantic Beach,FL 32233 Phone:904-278-0339 Fax:904278-0366 2018 -Jan Phone:(904)217-0739 Fax(904)814-8173 wtnnntmcgowansac.com saldie@mcgowansac.com wowvtollbrothers.com smerten@tollbrothersinc.com MILLENNIUM ollth METALS, I 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) OFFICE COPY FAX 904-358-8285 Net Coverage 1 6" Nominal L\ PANEL PROFILE DIMPLE APROX. a. EVERY 4" O.C. STARTER/END SLOT APROX. 2' FROM PANEL ENDS , Sidelap Detail Nailstrip Detail NOTES: 1. M-Seam Panels are only available with minor ribs to reduce oil canning. 2.011 canning is inherent to all metal panels and therefore is not considered a manufacturers defect nor a warranty condition. 3.Consult your contractor immediately if you need information concering this condition. Gauge Finishes Nominal Thickness ASTM & Grade Specifications 26 Acrylic Galvalume .0179 ASTM A-792 AZ55 26 PTD Galvalume * .0179 ASTM A-792 AZ55 24 Acrylic Galvalume .0240 ASTM A-792 AZ55 PTD Galvalume is 70%Kynar 500 or Hylar 5000 PVDF Resin unless otherwise indicated. Millennium Metals Offers a Limited 25 year warranty on Painted Panels,20 year limited warranty on Mill Finished Acrylume Panels. Please request warranty information from your distributor. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 1 MILLENNIUM • METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 M-Seam Installation Instructions: Panel Attachment: M-Seam recommended attachment is 8" on center along the edge of the nailer strip. This attachment may not be suitable for all applications. Projects may require an engineer to evaluate conditions such as mean height, exposure type, and roof configuration as indicated in ASCE 7-98 and ASCE 7-02. Additional fasteners may be required along the end zones on the panel (eave, ridge, and perimeter). Pitch Alert: This product should not be used on applications less than a 2/12 pitch. Roof Application: Step 1: Make sure deck is even and square. Step 2: Panel should begin on the gable end opposite of the prevailing wind. Begin with the receiving edge of panel (female side) along the Gable (see Gable Rake Detail). The edge away from the Gable should be the nailstrip. After checking that the panel is square to the eave, make sure the panel is attached as indicated in panel attachment(see above) and also 2" from the leading and trailing end of the panel on the nailstrip. The screw should be placed in the center of the nailstrip slot provided. Sealant is recommended on applications less than a 3/12 pitch. Step 3: After attaching the first panel completely,panel 2 should be snapped in place using a rubber mallet. A minimum of 1" overhang is recommended at the eave. Typical eave detail requires the use of a hemming tool to hem the panel over the ED2 (detail has 1-1/2" overhang). Install the remaining accessories. Millennium Metals offers a variety of products such as pipe boots, butyl tape, and ventilation materials. Do not use copper or lead products in conjunction with M-Seam as it will void the warranty. ATTENTION INSTALLER: PLEASE REFER TO THE IMPORTANT NOTE SECTION OF THIS MANUAL FOR SAFETY, STORAGE, OIL CANNING DISCLAIMER, AND SHAVING DISCLAIMER PRIOR TO BEGINNING PROJECT. Code requirements vary from area to area and job type as well as roof configuration. Job specific engineering is not a service provided by Millennium Metals. Estimates/Takeoffs are provided at a nominal fee for materials only. It is the sole responsibility of the customer to review the takeoff and make any changes to the quantity, length or accessories he/she feels necessary. Millennium Metals takes no responsibility as to the accuracy of the information provided. M-Seam is a special order product and therefore is not returnable. Please verify all items prior to ordering. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 2 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 Important Notes: Millennium Metals recommends licensed roofing professionals to install our materials. Please use gloves, glasses, and other protection when handling material to prevent injury. It is necessary to inspect deck integrity to insure it is safe to walk on before beginning any work. Millennium Metals recommends all installers follow the OSHA requirement for fall protection. Never walk on materials when wet or when unsuitable weather conditions are present. Storage: Materials should be installed immediately. Any unused materials should be stored in a dry place where moisture will not reach and penetrate bundles. Material should always be placed on wood block to separate from the ground or concrete. Do not cover with plastic!!! Instead, use loose canvas tarps so that air can circulate. Cut the bands so that the material can expand. Millennium Metals warrants the material only. We do not offer weather tightness warranties. Any such warranty is up to the contractor to include in their contract. Decking: Millennium Metals recommends the use of minimum 1/2" plywood or OSB Board attached in accordance with code. The deck must be supported by an engineered truss system not to exceed 24" on center. A moisture barrier such as 30# felt or other ASTM approved underlayment should be used over decking to control moisture. Metal should never come in direct contact with green or pressure treated lumber as it will cause corrosion. If tin tabs are required to attach felt it will be necessary to apply a 15# felt in the direction of the panel as an additional separation barrier. M-seam is recommended on application with 2-1/2 / 12 or greater. Oil Canning Disclaimer: Oil canning is industry wide and inherit to all metal panels. It is more visible in designs with flat spans as with this panel. Oil canning is a wavy appearance in the surface of the metal panel. This slight distortion in no way effects the warranty nor is a reason for rejection or refusal. Shavings Disclaimer: When using fasteners to penetrate steel sheets the iron particles tend to go airborne and settle on the sheet. It is necessary to remove these particles to prevent embedment and rust marks. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 3 MILLENNIUM 0 METALS, INC. M-SEAM DETAIL LOCATIONS 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 SR-1 RC-10 GR-9 RC-15 RAKE EDGE RIDGE �'�,, PAGE 8 SW-3 PAGE 6 SW-4 i E SIDEWALL 0 14 � PAGE 10 TF-2 m i- TRANSITION o oib- EW-3 ��i PAGE 9 Z ENDWALL iii" `� .♦ I/__ 1116 n PAGE 11 / IIMMINISNAMOSIMININOW MILLENNIUM • • METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 1. EAVE DRIP (EF-5) 2. ENDWALL FLASHING (EW-3) 3. EXTENDED EAVE (ED-2) 3. EXTENDED EAVE (ED-2R) 3 Sin, PAINT - S 3/8., PAINT /-../...........:..........,3/8,... \� 4 3/4, PAINT PAINT /\\�� N ',. 1 5/8" 17 4 1/2, 2 1�2' N. 1 1/2" 1" N - _ X�5/8�. 1 1/2� X 5/8.. 1/2" 1/2" OVERHANG: 1-r OVERHANG: 1-i" 4. GABLE RAKE (GR-9) 4. GABLE RAKE (GR-9R) 5. GAMBREL FLASHING (GF-2) 6. HIGHSIDE EAVE (HS-1) 3-1/8" 3-1/4" 2 I I 7-1/4 E k NI _ -----------NN< Tf \ 1+ tcs, 4 5/8'T 5/8 5/8" 1/2""k a 1/2" )X . 5/8 7. HIP CAP (RC-10) 8. J-CHANNEL (JC-7) 9. PREFORMED VALLEY (PV-3) 10. STEP SIDEWALL (SW-4) 5�5�$ 4-1/2" 9�//?.. i� -3/B'• 1" 1-3/8" I1"I 12-7/8" I6-' ` 5/8" 11, TRANSITION FLASHING (TF-2) 12. SIDEWALL FLASHING (SW-3) 13. STEP RAKE (SR-1) 14. COUNTER FLASHING (CF-1) 1/2">C 3" f R, -CO 3-3/8" / ?(1-1/16" I I n /4• ro 44-1/2" I n �(, 5/6" �� �'�' it 1/2" _ '/� 11/2" 1/2, 1/2 ( 3/4" 15, RIDGE CAP (RC-20) CLEAT OFFSET CLEAT (CL-2) Z-CLOSURE (ZC-1) REGLET FLASHING (RF-1) 1" 1/2")‹ 6 \121-1/2.. 1" -H♦- XL N /2" I j f- I ato c.— /` \x' 1 L N 1I2 1 3/8" FLASHING PROFILES MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 5 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 STITCH SCREWS RIDGE CAP _ 0 12" O.C., DO NOT OVERDRIVE M-SEAM PANEL VENTING MATERIAL / I' 30# FELT 4,1 ATTACHED PER CODE APPROVED SOLID SUBSTRATE VENTED RIDGE DETAIL RC- 15 qty . M-SEAM PANEL S.S. POP RIVETS / "Z" CLOSURE CUT TO FIT BETWEEN PANEL (3) #10-12 X 1" PANCAKE HEAD SCREWS PER PANEL CONT. BUTYL TAPE SEALANT / APPROVED SOLID SUBSTRATE #30 FELT ATTACHED PER CODE HIP/RIDGE FLASHING RIDGE CAP RC-10/RC-20 MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 6 MILLENNIUM 0 METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 \, \ \ \ \'. M-SEAM HEMMED \u ,. \\\ ta. '' \ 4 \ \ \\ '. SEE DETAIL FOR HEMMING #10-12 X 1" PANCAKE \\ \ \ PANEL PAGE 3 HEAD SCREWS ® 12" O.C. iiLI, \ \\ M-SEAM PANEL #30 FELT (. ATTACHED PER CODE )\*1:„1 ,1' Ill APPROVED SOLID SUBSTRATE # . CLEAT W/ #10-12 X 1" PANCAKE HEAD SCREW 0 12" O.C. ___, FASCIA BOARD EAVE DRIP DETAIL ED-2 EAVE FLASHING PANEL SHOWN SHORT TO ICI DETAIL. MAKE IT FLUSH AND PMAKE HOLE. II S.S. POP RIVETS M-SEAM PANEL ,: _.... ,:,- .' `, 0 12" O.C. i• HIGH-SIDE EAVE FLASHING 13-,0' .........._...-._.._.__ .. 7" CLOSURE CUT TO FIT BETWEEN PANEL (3) #10-12 X 1" ii"li ,. PANCAKE HEAD SCREW PER PANEL 6 , Y ,; iil APPROVED SOLID J // SUBSTRATE #30 FELT ATTACHED PER CODE CLEAT W/ #10-12 X 1" PANCAKE HEAD SCREWS 0 12" O.C. CONT. BUTYL TAPE SEALANT HIGHSIDE EAVE DETAIL HS-1 MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 7 MILLENNIUM • METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 -- I , 1.- R / E N D s'',,,,,,,, ', PT,.s., '''',.,„,,,,,......j7t'y ,,,,,,,,,,--.2,',';!'/' ii '',, ``<./T!', - FIELD BEND j ‘qr i PANEL. MIN. '1? CONT. BUTYL 0;',r TAPE SEALANT .----: ✓,✓ STITCH SCREWS ' i�� 0 12' O.C. �– 30# FELT ATTACHED PER CODE % ✓, STITCH SCREWS 0 12. O.C. 1A–SEAM PANEL e-j'' CONT. BUM TAPE SEALANT ;'n;., gra Ir. ''44,71I-71:''' STEP GABLE FLASHING STARTAl4 APPROVED SOLID SUBSTRATE FASCIA CLEAT W/#10-12 X 1" STEP GABLE RAKE DETAIL SR-1 PANCAKE HEAD SCREWS "' r ��a \ E N D ti '`�`�` `\\ ..``, i`? Wyss i! ,` -:4 4<, ,y%` FIELD BEND PANEL 1 MIN. '� CONT. BUTYL \-, TAPE SEALANT �. 'Z. CLOSURE GABLE FLASHING • STITCH SCREWS ✓ 0 12 O.C. ' ,` 30# FELT ATTACHED PER CODE ,�%� r''✓s APPROVED SOLID SUBSTRATE \t, / 11–SEAM PANEL CI '¢,j 'Z' CLOSURE CUT TO FIT BETWEEN PANEL, (3) #12 X 1 WHS PER PANEL START ,% CONT. BUM TAPE SEALANT FASCIA CLEAT W/ #10-12 X 1" PANCAKE HEAD SCREWS GABLE RAKE DLIAIL GR-9 MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 8 MILLENNIUM IAN METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 \ /// , // I • //:/// • /%/ \\ _..,, „, , , , ,„,.....„ ., ,,,.„„ ,. . v... J ..r " 1 r: _Q., ,,.1,Y, ' M-SEAM PANEL „ .._. \_.,,....,,, .. ..... #30 FELT ATTACHED PER CODE -VALLEY FLASHING APPROVED SOUD SUBSTRATE CLEAT SET IN BUTYL TAPE CONT. BUTYL SEALANT W/ #10-12 X 1" TAPE SEALANT PANCAKE HEAD SCREWS 6" O.C. PREFORMED VALLEY DETAIL PV-3 \ \\ OFFSET CLEAT SET IN \` ,-i BUTYL TAPE SEALANT W/ #10-12 X 1' PANCAKE ' moi/ HEAD SCREWS O 12' O.C. ' t- • TRANSRION FLASHING �' S.S. POP RIVETS /`�,. 0 12" O.C. `Y \ c\T\\ i/ �I\\� \\\ CONT. BUM TAPE SEALANT ` A.11\11:� �� "Z" CLOSURE CUT TO FIT BETWEEN Nva\ \N PANEL (3) #10-12 X 1" PANCAKE �i`- SCREWS PER PANEL lv, M-SEAM PANEL ` 30# FELT ATTACHED PER CODE APPROVED SOUD SUBSTRATE TRANSITION DETAIL MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 9 MIllENNIUM oillvs METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 SEALANT CONT. BUTYL SEALANT TAPE SEALANT , s. ;.' SURFACE-MOUNT A.It• CONT. BUTYL TAPE /rt, COUNTER FLASHING j; SEALANT 1't SIDEWALL FLASHING S.S. POP RIVET ,.. 1 Ir COUNTER FLASHING ® I ® 12" O.C. "Z" CLOSURE CUT TO FIT ' STEP SIDEWALL BETWEEN PANEL, (3) #12 X 1 FLASHING PANCAKE SCREWS PER PANEL #30 FELT A/ P i ATTACHED / s�° /i �:7 /// PER CODE // , // i �% i/ CONT. BUTYL TAPE // / APPROVED SOLID----- SEALANT ^_ // / SUBSTRATEr, /' #30 FELT ``t.et `.,... J 4 // STITCH SCREWS 't'• ATTACHED PER CODE 4',7). ,. 0 12" O.C. `��- APPROVED SOLID CONT. BUTYL TAPE SUBSTRATE SEALANT M-SEAM PANEL M-SEAM PANEL SIDEWALL FLASHING DETAIL SW-3 & SW-4 SIDING/STUCCO -` SEALANTA ����,' SEALANT 4111IV s•a• CONT. BUTYL I' le REGLET TAPE SEALANT FLASHING W FLASHING SAW CUT11 CONT. BUTYLtriTAPE SEALANT 0 CONT. BUTYL SIDEWALL FLASHING TAPE SEALANT '. MASONARY WALL , ‘-STEP SIDEWALL FLASHING \ SIDEWALL COUNTER FLASHING OPTIONS MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 10 MILLENNIUM AIN METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 SEALANT 111111111111111:,,,,,,--:; CONT. BUTYL TAPE SEALANT SURFACE MOUNT COUNTER FLASHING HEADWALL FLASHING \\ ft CAULK 0 ALL SEAMS IL' fl CONT. BUTYL TAPE SEALANT \\\\ "Z" CLOSURE CUT TO FIT BETWEEN \ PANEL, (3) #10-12 X 1" PANCAKE N HEAD SCREWS PER PANEL S.S. POP RIVETS \\: \\ ;> .- M-SEAM PANEL � \\ APPROVED SOLID SUBSTRATE N \ ,,"="1-'d j MILLENNIUM S METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 PANEL HEMMING , 7 7 s ji-s..)J, -,..) _ ` . S ••` 7 S 2+, S S �, B -41.111111116. IlL .44'444,4w AVON, ..4%. ...._. CAULK _ ) CUT PANEL BACK 1 4" TO CREATE HEM. USE HEMMING TOOL. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 12