Loading...
1449 OCEAN BLVD MOD & SHINGLE ROOF ri rL`Jrl J� CITY OF ATLANTIC BEACH y 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF18-0030 Description: MODIFIED AND SHINGLE ROOF Estimated Value: 2800 Issue Date: 3/19/2018 Expiration Date: 9/15/2018 PROPERTY ADDRESS: Address: 1449 OCEAN BLVD RE Number: 171862 0000 PROPERTY OWNER: Name: WHITAKER LAMAR H Address: 1449 OCEAN BLVD ATLANTIC BEACH, FL 32233-5745 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: DS KILLIAN ROOFING Address: 1031 MIMOSA COVE CT E QA DAVID S KILLIAN ATLANTIC BEACH, FL 32233 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. 1 a,IiCity of Atlantic Beach APPLICATION NUMBER Js Building Department (To be assigned by the Building Department.) SS 800 Seminole Road i f Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904) 247-5845 :n/9 E-mail: building-dept@coab.us Date routed: ( ? City web-site: http://vmw.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1449 o �� GV c_ L�� Department review required Ye No 1. uilding Applicant: ') S K Tree Administrator Project: C'L Public Works Public Utilities Q C-) Public Safety Fire Services Review fee $ Dept Signature Review or Receipt Other Agency Review or Permit Required of Permit Verified t Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [/?Approved. []Denied. ❑Not applicable (Circle one.) Comments: ( BUILDING PLANNING &ZONING Reviewed by: 04; Date: 3 I6 Zo1 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denie ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: [—]Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 CITY OF ATLANTIC BEACH r ' AR 1 5 2018 800 Seminole Road ' Atlantic Beach Florida 32233 Qj ' REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date—(5-1 v Revision to Issued Permit Corrections to Comments ✓Permit# t'"opt �—Q0U L a Project Address �c'.lotyJ B�v� ' 3, � 5 Contractor/Contact Name 46S Phone �(� V(c 7&(o Email U Description of Proposed Revision/Corrections: Permit Fe ue $ Ste. O a Additional Increase in Building Value $/ Additional S.F. wof By signing below � l / C ' - G41`j affirm the Revision is inclusive of the proposed changes. (printed name) Sig a of Con gent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved ^ Denied Not Applicable to Department Revision/Plan Review Comments --Dep_artment Review Required: Building Planning& Zoning Reviewed By Tree Administrator Public Works Public Utilities 3�1 612W Public Safety Date Fire Services Building Permit Application Updated 12/8/17 City of Atlantic Beach u 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 Job Address: { ' r 0ob tI 9/ Permit Number: ROOE I F --OCLS0 Legal Description ��`I' 'aS– 99 E A CL N F4 Lot 7 C�np4NK+R0 E# �7o g-s" b 13 O o2 Valuation of Work(Replacement Cost)$ c�0 Heated/Cooled SF Non„Heated/Cooled f e MTiCo I_� • Class of Work(Circle one): New Addition Alteration epair ove Demo Pool Window/Door • Use of existing/proposed structure(s) (Circle one): Commercial esidential • If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the hype of work to be performed: lt Par -1Glf (-100t eQC6Mef,� M 0 Florida Product Approval# F�-- 17. fL for multiple products use product approval form Property Owner Information L ///L� �� �� Name: W)of w cl ��� Address: 1 y / hy _ City 4 1C Pot State zip �oZ�3.� Phone 2041 E-Mail 1,�et-wbe P OWI Owner or Agent(If Agent, Power of Attorney o Agency Letter Required) Contractor Information Name of Company: D5 el 14 )2hC t Qualifying Agent: a//td k''J/('4r q Address 0 f of/ted 0 C4--L—:-- City 6 State f:71- zip 3 Office Phone czolf -A V& -76(p 3 Job Site/Contac Number Seq State Certification/Registration# GCc 1 A S' O E Mail �GCMG �.�.1 /G• It'4,a - C yh Architect Name&Phone# /J Q Engineer's Name&Phone# w9 Workers Compensation NA 1 C 0 C-)3 – 0 (-_7 CDC> Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WE`4�e,WLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this \'OSKit,them be additional restrictions applicable to this property that may be found in the public records of this county, and nal permits required from other governmental entities such as water management districts,state agencies,or may federal a4! 01. `� JVtERs AfCl/ certify that all the foregoing information is accurate and that all work will be done in compliance with all Iic' iI�laws�vegul.Sing construction and zoning. :� •Qa� Jp 1a• lf�(C�*T(��WNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMEL�TP � Nq�'�i��� 'kit AOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF1:3,��Oo> di( TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BE Q� ���` RECORDI G YOUR N TICE OF M'MENCEMENT. - =�(j YFF 115410 t j9�••�°.d Ba'70ad thN e�•'OQ�� (Signature of Owner c r A ent) ignature of Contractor) (including contractor) Signed and sworn to(or affirms beforepe this day of Signed and sworn to for affirmed efore me this ay of l�lr I►tn11 (C / F� �,by &rnm- al Glad, W” //� ta y/ (Signature of Notary) (Signature o ory) [ Personally Known OR [ ]Personally Known OR [ ]Produced Identification [ Produced Identification Type of Identification: Type of Identification: OFFICE COPY Doc # 2018050973, OR BK 18302 Page 1590, Number Pages: 1, Recorded 03/05/2018 11 : 48 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 Pe 4 12Ga�' l � - a� sd NOTICE OF COMMENCEMENT State of F/I — _ Tax Folio No, 7 County of--La —— -- 'fo Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this K TICS OF COMM 'NC=FT. Legal Description ofproperly being improved: (��,a -p21W-q�� N 304 4o.L Address of property being improved:__LZy vt,•Pt�j U General description of improvements: arCt L. y� aC eh Owner: —►�laJ`� e� _ _ Address: Owner's interest in site of the improvement: f (t Fee Simple Titleholder(if other than owner): — — — --— —-- — Name: _ Contractor:• /�� E;�, Address: — Tcicphone No.: If.:; Fax No: —. — ---. --- -- Surety(if any) Address:— — ---— -- — ---- Amount of Bond S Telephone No: _— --——.——. Fax No: --- Name and address of any person making a loan for the construction of the improvements Name:—,/ f -- —--—— -------- -- — -- Address: Phone No:— _. —..------ Fax No: —...— — ---—— ---- Name of person within the State of Florida,other than himself.designated by owner upon whom notices or other documents may be served: Name: fi= —-- --- --- --- — — Address: 'telephone No:.-- — -------- Fax No: —... -- -- --In addition to himself, owner designates the following q►i1!(111 g g person to receive a copy of the Lieitor`s Vutice 713.06(2)(b),Florida Statu . (Fill in at Owner's option) �� F Name:_ ---- — -- -- -- �`\ "z —---- Address: - ' z Telephone No:_ --- — Fax No: _ 3M. O ruro :*z - —. Expiration date of Notice of Commencement(the expiration date is one (1)year from the date of recordin � " °' to is specified):. ZX). THIS SPACE FOR RECORDER'S USE ONLY OWNER Signcd:- _ Date: Bel'ont this dad of r y�the C unt of�?u al Sl tc Of Florida,has personally appeared QtK _ Yj'r1 �_ Notary Public at 1 arge,State of F ori a.Cggun�oof Duval. My commission expire /�..atij,d6/D Personally Knovm: C or Produced Identificatio -- - OFFICE COPS' EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization#9503 VT--PJJN11Y1ERD 353 Christian Street, Unit 13 Oxford,CT 06478 (203)262-9245 EVALUATION REPORT GAF Evaluation Report 01506.11.05-1119 1 Campus Drive FL5680-1119 Parsippany, NJ 07054 Date of Issuance:11/07/2005 (800)766-3411 Revision 19:09/22/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: GAF Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TRINITYI ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 86-page Appendix. Prepared by: Robert J.M.Nieminen,P.E. 's°T•,F. ;,;c:✓_fir' r,FS ..:..; The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166,Florida DCA ANE1983 � �.��+ov�`ti:�``�� P.E.on 09/22/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. vrriuc uvr i LIBERTY® TM gaf.com SBS Self-Adhering Roofing System How Do 1 Prepare for a Liberty'"Project? Before You Start..the installation of your new Liberty"SBS Self-Adhering Roofing,do the following: •Read Instructions Thoroughly...and understand how the entire system works before starting your installation. •Understand The Materials...know when and where to use each component,why each is necessary,and the common mistakes to avoid. •Contact GAF Technical Services...at 1-800-ROOF-411 for detailed information on specific applications. Do's And Don'ts...Liberty"SBS Self-Adhering Roofing Systems are designed to be installed over low-sloped roof decks. •Do Install On Roofs Between 1/2"And 6"Per Foot Incline...and backnail the Libertyy'Cap Sheet when the slope is greater than 1"per foot. Contact GAF Technical Services at 1-800-ROOF-411 for fastening requirements specific to your project. •Do Install In Moderate Temperatures...between 45oF(7°C)and 95°F(35°C),to assure proper adhesion and easier work conditions. IE 7War •Do Install Over Clean,Smooth Surfaces...that are free of dirt,debris,and damage,or are otherwise unsuitable for installation.•Don't Work Alone...GAF recommends at least 2 people install Liberty'"SBS Self-Adhering Roofing. SAFETY FIRST...Protect yourself and others.Consider the following common-sense safety precautions,including: •Wear appropriate clothing,including protective footwear,eye wear,and gloves. •Be aware of your surroundings.Watch for power lines when working near ladders and use common sense on your job site. •Follow local building codes. •Bend at the knees.Never lift with your back. Wear Gloves 13 Precautionary Note: The application instructions for this product require the use of primers,adhesives,or cements that contain Common solvents.Apply solvent-based products ONLY as instructed. Excess application of solvent-based products may affect the performance Q Mistakes of this product, delay application of the cap sheet,cause surface blistering of the cap sheet,or result in the asphalt flowing, dripping, or and Haw to Avoid Them staining. You may notice unpleasant odors from the solvents,which will dissipate when the solvent-based product has dried. What Tools & Equipment Do 1 Need to Install a Liberty" Roof? o O Trowel Gloves Hammer Utility Knife Weighted Roller Brush Tape Measure Caulk Gun LibertyV'Installation Kit Liberty" Roof Materials... What Do I Need to Install a Quality Roof? •Liberty'"Installation Kit...comes with enough primer and cement to install approximately 200 square feet of membrane. Additional kits or extra primer and cement may be purchased if necessary. •Liberty'"Self-Adhering Base/Ply...is the base weatherproofing layer when applied over acceptable,prepared decks or insulations.Each roll contains approximately 200 square feet. •Liberty'"MA Mechanically Attached Base...is applied when the deck is unsuitable for self-adhered sheets or when a nailed base sheet is preferred.Each roll contains approximately 200 square feet. •Liberty'"Self-Adhered Cap...is the first line of defense from the weather.Each roll contains approximately 100 square feet. •Metal Flashing...for covering roof perimeter edges.Metal flashings are typically sold in 10-foot sections and must be primed with asphalt primer and allowed to dry before installation. •Everything Else...when measuring,note the size and number of vent pipes,and other flashings.Don't forget any nails,lumber, or other additional materials that you may need. Liberty" Roof Systems... Which Roof is Right for Me? 2-Ply Lay-out(SA Base) 2-Ply Lay-out(MA Base) 3-Ply Lay-out Nallable Deck 1C Mal. Mi_— USERTY' �•AI.OW0aaaaard We. NIe d-Mln Sratap de lap Side Lap ove am" 7MIn ISide LapC MIn 31W Mn. LIBERTY' LIBERTY" LIBERTY- m MA BASE SHEETT CAPSHEET UBERTY"YA BASERLY SHEET SHEET 1U67LY SHEET CAP SHEET Note:Single-ply application not shown;visit gaf.com for details if required. OFFICE COPY 18B_ 19„ STEP 1 - Preparing for a Liberty'" Roof... Is the Surface Ready? •Remove All Existing Roofs...a LibertyTM MA Mechanicand determine the suitability of the existing roof deck.Alternately, Ob lly Attached Base ma be installed over certain roof types or deck types not listed.Contact GAF Technical Services at 1 800-ROOF-411 for more information. •Inspect The Deck...and determine what type of preparation is required.Replace damaged deck O o 9„ materials as necessary. Install Insulation(if desired)...using GAF DRILL-TECTM screws and plates or GAF approved adhesives. taw^ •Use minimum 1/2 thick EnergyGuardTm Polyiso Insulation with approved fiberglass or paper facer. o a Acceptable Decks .-o_�_........6. 15/32"Minimum Plywood..........Apply light asphalt primer at 1/2 to 3/4 gal per 100 sq.ft. Fastening GAF EnergyGuarl Polylso Insulation..........Install LibertyTMSelf-Adhered Base/Ply Sheet directly to insulation. Other Deck Types May Be Acceptable..........Contact GAF Technical Services at 1-800-ROOF-411 Liberty'Sell-Adhering Cap Sheet for more information. IBT,ip �:'Beep i Bib6an 01 Mains'201 Premium SBS Common Mistakes(and How to Avoid Them)... Flashing CamenlCarering , Ir The Edge Beneath Poor Roof Drainage... can lead to leaks at the seams.Before installation,fix the roof deck at locations where water remains after 48 hours. Clip under,hla Comm,At 45• •Not Priming The Deck... or metal may lead to poor adhesion and is a leading cause of problems. Angle At All End Laps 6"Min STEP 2 - Installing Liberty" Base Sheet... Nailed Base or Adhered Base? 1. for 1.Align Base Sheets...Starting at the lowest point of the roof where there are gutter or fascia edges, "UNextend the base sheet over and down the fascia fully behind the metal edge or gutter height fastened along roof edge and along fascia 9'o.c.Minimum overhang is 1 .Begin with 1/2 width (19 11/16")sheets in 2-ply systems.Use 1/3 width(131/8")starter sheets in 3-ply systems and install d ply(interply sheet)starting with 1/2 width(1911/16")sheets to maintain side lap offsets. N"Bad Of Maois" 2111 Premium SBS ®2.Install MA Base Sheet(Where Required)...using nails with 1'cap heads.Fasten every 9"in the lap a Flashing Cement and stagger 2 rows in the field every 18' (see Fastening detail).Cover the entire roof area. 3.Install Self-Adhered Base Sheet...by aligning sheets properly before removing the release liners.Roll out sheet and let it sit or"relax"for at feast 30 minutes to minimize the potential for wrinkles that can form during installation.Remove one side of the release liner at a time. 4.Overlap Following Rows of Base Sheet...horizontally(side lap)by using the line found on the base End Lap sheet.Remove release films from top and bottom half of sheet in turn,carefully rolling back into position to maintain overlap.Where no line is present,overlap by 3".Overlap vertically(end laps)by at least 6". Make sure all end laps are at least 18"apart. 5.Roll Base Sheet Into Place(Base Onl )..using a weighted lawn or linoleum roller. P"med Edge Flashing,Sag Flashing Cement Ce ent y Malrl,'201 Prtmlum SBS Flashing C t Matrla"201 This improves adhesion to the deck and ensures propeely sealed laps. Premium SIS Flashing Cement Br.e. NOTE:A base sheet is not required;visit gaf.com for more information. Caminaaa, Mesal clad e;L@eM-Sall-Adhering Cap Sheat Common Mistakes(and How to Avoid Them)... � •Not Letting The LibertyTM Sheets Relax...can lead to wrinkles.In colder weather,the rolls require more � time to flatten. rise Math:201 Premium •Not Rolling The Base Sheets...Is a leading cause of opening laps.Always pay close attention to laps when SBS Flashing Cement rolling the base sheets. Fasteners a•O.G.Staggered STEP 3 - Installing Liberty- Self-Adhered Cap Sheet... Where Do I Begin? L,b,rt,-11...Sheet 1.Install Edge Flashin ...over the base sheet in a 1/8"bed of cement and stagger nail with two rows of g g P.a a e Tnishal ad roofing nails.3' o.c.Prime the face on the roof and allow to dry before installing cap sheet. Nailer Methant,all,reddened Edu g,gals,nsa,a..an 2.Align Cap Sheet... 1/4"from the edge at the lowest point of the roof.Roll out and position full width(39 3/8")sheets with the selvage edge on the high side of the roof.Allow sheet to relax ® for at least 30 minutes prior to installing. 3.Overlap Following Rows...horizontally(side lap)6'by aligning with the bottom of the selvage edge. Edge Flashing Vertical(end laps)must be overlapped by at least and applied in a 1/8"bed of Matrix'"201 SBS Flashing Cement.Make sure all end laps are at least 18"apart and have clipped corners(see End Lap Shingle underlayment detail).GAF recommends installing a bead of plastic cement along the step up length of the lap. \ Shingles 4.Remove Release Films...from top to bottom half of sheet in turn,carefully rolling back into position to maintain overlap. Remove selvage edge release film prior to installing bottom Half of sheet and • finishing the side lap. Fasteners 5.Roll the Cap Sheet Into Place...using a weighted roller.This improves adhesion to the base sheet approx.rill and ensures properly sealed laps. Lill Common Mistakes(and How to Avoid Them)... Base (lashing must •Not Priming the Edge Metal...can cause the cap sheet to peel away at the edges.Always prime extend edge metal before installing cap sheet. d a minim m ' 013 course • •Not Applying Cement at the End Laps... can cause laps to open.All locations where sheets extend of shingles, r over granules must be set in cement. Fasteners •••" aQprgx. �B• STEP 4 - Cleaning Up and Maintaining Your Liberty'" Roof8 o.c.... LibertyTM •Remove All Tools and Materials From the Roof...and make sure there is no debris that can slow or flashing must E stop the flow of water. extend up a minimum of •Dispose of Materials Properly...following all federal,state,and local laws. 3 CeurSeS el Matrix"201 Premium shingles. SBS Flashing Cement •Inspect the Roof Annually...and remove any leaves,branches,or vegetation that may be present. Plywood Deck Look for other damage and repair if necessary. ®as Keep Gutters Clean...to ensure proper water flow and minimize the possibility of damaging ice dams. Shingle Tie-in =' LIBERTYT" 02013 GAF 9/13"#349 RESLB108 gaf.com SBS Self-Adhering Roofing System TRIIr111-Y ERD TABLE 1A: WOOD DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP(psf) No. (Note 1) Type Attach Type Attach Base Ply Cap Min.19/32-inch Min.1.5-inch Min.0.5-inch Structodek High (Optional)One or more SBS-AA,S85-TA or W-1. plywood or 05B at max. EnergyGuard RA, GAF 2-Part Density Fiberboard Roof GAF 2-Part BP-AA,SBS-AA BP-AA,SBS-AA,SBS-TA -52.5 24-inch span EnergyGuard RH, Insulation or APP-TA APP TA EnergyGuard RN Min.19/32-inch Min.1.5-inch Min.0.25-inch Dens Deck, (O One or more (Optional)) W-2. plywood or OSB at max. EnergyGuard RA, GAF 2-Part Dens Deck Prime or GAF 2-Part BP-AA,SBS-AA,5BS- BP-AA SBS-AA,SBS-TA SBS-AA,SBS-TA or -52.5 24-inch span EnergyGuard RH, SECUROCK Gypsum-Fiber TA or APP-TA or APP-TA APP-TA EnergyGuard RN Roof Board Min.19/32-inch Min.1.5-inch Min.0.25-inch Dens Deck, WeatherWatch XT W-3. plywood or OSB at max. EnergyGuard RA, GAF 2-Part Dens Deck Prime or GAF 2-Part Mat Surfaced Leak (Optional)SBS-TA,APP- SBS-TA,APP-TA -52.5 24-inch span EnergyGuard RH, SECUROCK Gypsum-Fiber Barrier TA EnergyGuard RN Roof Board TABLE 113-1: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) MDP No. (Note L) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf) CONVENTIONAL SYSTEMS: Min.1-inch Min.0.5-inch GAFGLAS#75 Base Sheet, 32 ga.,1- 8-inch o.c.at EnergyGuard Polyiso Structodek High Min.15/32 Tri-Ply#75 Base Sheet, 5/8-inch dia. min.4-inch laps Insulation, Density Fiberboard (Optional) inch GAFGLAS#80 Ultima Base tin caps with Hot Hot BP-AA,SBS- and 8-inch o.c.in EnergyGuard Ultra Roof Insulation or BP-AA, SBS-AA, Sheet,GAFGLAS Stratavent 11 ga. asphalt asphalt AA W-4. plywood at two,equally Polyiso Insulation or EnergyGuard Perlite SBS-AA, SBS-TA, -45.0 max.24- spaced, EnergyGuard RH Recover Board or Min. SBS-TA, APP-TA ^ inch span Nailable Venting Base annular ring staggered center Polyiso or min.1.5- 0.75-inch EnergyGuard APP-TA `T, Sheet,Ruberoid 20 Smooth shank nails rows inch EnergyGuard RA Perlite Roof Insulation i ■ 1 or EnergyGuard RN (homogeneous) Min.1-inch GAFGLAS#75 Base Sheet, 32 ga.,1- 8-inch o.c.at EnergyGuard Polyiso Min.15/32- min.4-inch laps Insulation, (Optional) Tri-Ply#75 Base Sheet, 5/8-inch dia. inch and 8-inch o.c.in EnergyGuard Ultra Min.0.25-inch Dens BP-AA,585- BP-AA, SBS-AA, GAFGLAS#80 Ultima Base tin caps with Hot Deck Prime or Hot W-5. plywood at two,equally Polyiso Insulation or AA,SBS-TA, SBS-AA, SBS-TA, -45.0 max.24- Sheet,GAFGLAS Stratavent 11 ga. spaced, EnergyGuard RH asphalt SECUROCK Gypsum- asphalt APP-TA SBS-TA, APP-TA inch span Nailable Venting Base annular ring staggered center Polyiso or min.1.5- Fiber Roof Board APP-TA p Sheet,Ruberoid 20 Smooth shank nails rows inch EnergyGuard RA or EnergyGuard RN Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report 01506.11.04-1119 for FL5680-R19 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 19:09/22/2017 Prepared by: Robert Nieminen,PE-59166 GAF Modified Bitumen Roof Systems;(800)766-3411 Appendix 1,Page 5 of 86 OFFICE COPY TRINITY ERD i 4. PRODUCT DESCRIPTION: This Evaluation Report covers GAF Modified Bitumen Roof Systems installed in accordance with GAF published installation instructions and the Limitations/Conditions of Use herein. TABLE 1: ROLL-GOODS FOR GAF MODIFIED BITUMEN ROOF SYSTEMS Specification Type Product Reference Type Grade GAFGLAS®#75 Base Sheet ASTM D4601 II N/A Tri-Ply#75 Base Sheet ASTM D4601 II N/A GAFGLAS°#80 Ultima'"Base Sheet ASTM D4601 II N/A Base Sheet StormSafe"Anchor Sheet Proprietary N/A N/A GAFGLAS®Stratavent®Nailable Venting Base Sheet ASTM D4897 II N/A GAFGLAS®Stratavent®Perforated Venting Base Sheet ASTM D4897 II N/A Liberty-SBS Mechanically Attached Base Sheet Proprietary N/A N/A GAFGLAS® Ply 4 ASTM D2178 IV N/A Ply Sheet Tri-Ply®Ply 4 ASTM D2178 IV N/A GAFGLAS®FlexPlyT'6 ASTM D2178 VI N/A Liberty"SBS Self-Adhering Base/Ply Sheet ASTM D1970 N/A N/A UnderRoof'"HT High Temperature Leak Barrier ASTM D1970 N/A N/A WeatherWatch®XT Mat Surfaced Leak Barrier ASTM D1970 N/A N/A Ruberoid®20 Smooth ASTM D6163 I S Ruberoid®HW 25 Smooth ASTM D6163 I S Smooth Surfaced Ruberoid®HW Smooth ASTM D6164 I S Membranes: Ruberoid®Mop Smooth ASTM D6164 I S Ruberoid®Mop Smooth 1.5 ASTM D6164 I S Ruberoid®Mop Plus Smooth ASTM D6164 II S Ruberoid®Torch Smooth ASTM D6222 I S Tri-Ply®APP Smooth ASTM D6222 I S Ruberoid®30 Granule ASTM D6163 I G Ruberoid®30 Granule FR ASTM D6163 I G Ruberoid®EnergyCapT"30 Granule FR ASTM D6163 I G Liberty"SBS Self-Adhering Cap Sheet ASTM D6164 I G Ruberoid®Mop Granule FR ASTM D6164 I G Ruberoid®Mop Granule ASTM D6164 I G Intec Flex PRF ASTM D6164 I G Tri-Ply®SBS Granule ASTM D6164 I G Ruberoid®HW Granule ASTM D6164 I G Ruberoid®HW Granule FR ASTM D6164 I G Granule Surfaced Ruberoid®Mop Plus Granule FR ASTM D6164 II G Membranes: Ruberoid®Mop Plus Granule ASTM D6164 II G Ruberoidm EnergyCapT"Mop Plus Granule FR ASTM D6164 II G Ruberoid®HW Plus Granule ASTM D6164 II G Ruberoidm HW Plus Granule FR ASTM D6164 II G Ruberoid®EnergyCapT"HW Plus Granule FR ASTM D6164 II G Ruberoid®Torch Granule ASTM D6222 I G Tri-Ply®APP Granule ASTM D6222 I G Ruberoid®Torch Plus Granule FR ASTM D6222 II G Ruberoid®EnergyCap'"Torch Granule FR ASTM D6222 I G Ruberoid®EnergyCap'"Torch Plus Granule FR ASTM D6222 II G Exterior Research and Design,LLC. Evaluation Report 01506.11.04-1139 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVH7 EVALUATION FL5680-R19 GAF Modified Bitumen Roof Systems Revision 19:09/22/2017 Page 4 of 6 Florida Building Code Online OFFICE COPY Page 1 of 2 Business & Professional Regulation rr= M BCIS Home 1 Lag In I User Registration IHot Topics Submit Surcharge Stats&Facts Publications i FBC Staff BCIS Site Map j Links ! Search Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Appllcetlon Detell FL# FL5680-R19 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany,NJ 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lindareith@trinityerd.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 Tech nicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M.Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 04/22/2018 Validated By John W.Knezevich,PE ® Validation Checklist-Hardcopy Received Certificate of Independence FL5680 R19 COI 2017 01 COI Nierrminen.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 FM 4470 2012 FM 4474 2011 TAS 114 2011 Equivalence of Product Standards Certified By hq://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDgt45H 1 a2AP3I... 12/14/2017