356 10th St right of way permit %J ' '.St CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 -5814 INSPECTION PHONE LINE 247 RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROW1 8-0005 Description: instal 35-ft. pole, replace transformer Estimated Value: 0 Issue Date: 3/21/2018 Expiration Date: 6/19/2018 PROPERTY ADDRESS: Address: 356 10TH ST RE Number: 1700430000 PROPERTY OWNER: Name: EZELIUS PER OLOF Address: 356 10TH ST ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JACKSONVILLE ELECTRIC AUTHORITY Address: 21 CHURCH ST W 3RD FLR JACKSONVILLE, FIL 32202 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. 'i City of Atlantic Beach el- r—_ '�' APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road op Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904)247-MAR 06 2018 E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: ­�)'s co !�i Department review required Yes No Building Applicant: IJE A Planning &Zoning ee Admi.nistrator Project: I Sk-CW 0\z -A- (,Publ[c WorL_s�) <,,,Pubficjj� Public Safety Fire Services Review fee Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engi neers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: JApproved. FIDenied. E]Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by�. Date: TREE ADMIN. Second Review: F]Approved as revised. E]Denied. F]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: F]Approved as revised. E]Denied. F]Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road MAR 0 6 2018 -0o Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904)247-5845 1 9, E-mail: building-dept@coab.us Date routed: City web-site: http://vmw.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: co [ c)-la S�j . Department review required Yes No Building Applicant: A Planning &Zoning ee Administrator Project: I () �VQ t t tA 0 6z WVk e- I Pubkc Work--s*) CL <:�P u bfii c_q� Public Safety Fire Services Review fee Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other.- APPLICATION STATUS Reviewing Department First Review: 3�(Approved. E]Denied. [:]Not applicable (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: Date: TREE ADMIN. Second Review: RApproved as revised. FIDenied. [:]Not applicable PUB WORK Comments: BLIC UTILITIES —?—zo—/9 PUBLIC SAFETY Reviewed by: Date'. FIRE SERVICES Third Review: DApproved as revised. OlDenied. [:]Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ok. 10 41 44 L4 .A#^A io 4o A .............. RIGHT-OF-WAY EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach owl PERMITTEE RE,SPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES — S/- - Job Address— s—(,-) /01-1-, Phone 9 a q Pennittee C-7 Iq Email S-,1,�g pr eeA Requesting Permission to Construct 0 ) 4 jalae_e yiz.�6, Location (Reference to Cross-Street) Se V"7 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as detennined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of 'T, eo k-,, (Project Superintendent) f with Company Name Ta-A Phone cn�I/ • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. 15 • The permittee shall commence actual construction in good faith within 6 0 days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be notified twenty-four(24)hours prior to starting work and again immediately upon completion. Date Permittee(signed in presence of Notary Public) STATE OF FLORJDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this_day of 20 by who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. Personally Known Signature of Notary Public,State of Florida Produced Identification(Type) ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:32756 N.O.: 8004473 WO#: 30250619 CONST 03/02/18 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O,: 563 REQ'D:YES CELL ENGINEER: Robert Simpson N.O.: N/A ZIP CODE: NIA CUSTOMER/ Svc PHONE LOCATION: 350 10TH STJ POLE INSTALLATION 563 CENTER: SSSC N.O.:665-7793 STA 1. P# 350 10TH ST./ INSTALL 35/4W -j w Ln \Nl -T POLE, RUN 2/OP TO STA 2. Ln Ln T 03 cy� j/oT STA 2. P# 351 1 OTH ST./ RE PLACE 45/3W T INSTALL 25 KVA. THIS IS FOR A NEW HOME BUILT TREE TRIMMING REQUIRED**—* 4 0 350 342 364 359 354 4 PVO 1 347 345 339 4 4 374 355 349 399 390 1 369 365 375 3� 397 393 379 0 4 STA 2 T VOT �j W T U) I/oT Ln W T Ln Un 03 I/OT ul uj I/OT -.j u-) c) 03 Li 2/OP Ln --A T Ln co 03 ------- T 0 ul) co--- --- 4/OP ....... —/T IMT CUE 1/0T /OT I/OT STA 1 4 4 3 4 349 344 340 3' 6 364 356 335 36 341 4 4 370 351 4 0 SEMINOLE RD. 3 361 4 365 36 4 71 375 391 395 4 Ln T 1/0'r 0 Ln WT n 1/0-f 0 Ll T TLj n �j 1/0'r Ln n 9T C) C-- 4C� IN \21 1/oT CUE Reports Estimate Number:32756 350 10TH ST.35/4W POLE INSTALL Estimate Type:GD Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30250619 Required Date: Oracle Project#:8004473 Estimated On: 03/0212018 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $1,876.58 $1,876.58 2.Transformer Cost(w/sales tax) $1,028.37 $1,028.37 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $1,264.34 $2.135.65 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $842.26 $156.84 7.Engineering Costs(Variable%of line 4) $279,40 $287.46 8.Project Equipment Costs(40%of total equipment costs) $747.52 $0.00 9.Material Handling(8.30%of lines 1 &2) $241.11 $241.11 10.Inspection(6.84%of line 4) $0.00 $146.08 11.Total Cost of Project $6,279.58 $5,872.09 12.Work Order Estimate(Line 11 minus line 8,9,&10) $5,290.95 $5,630.98 13.Billable Equipment Depreciation(60%of total equipment costs) $1,121.28 $0.00 14.Billing Estimate(including Transformer Cost)(Lines 11 +13+(58.71%of 4&7)) $8,307.19 $6,040.85 15.Billing Estimate(W/O Transformer Cost)(Lines 11+13+(58.71%of 4&7)-Line 2) $7,278.82 $5,012.48 Time Estimate Crew Hours Total Manhours 10.14 40�55 ----------------------------------------------------------------------------------------------------------------------------- CUE Reports Estimate Number:32756 350 10TH ST.35/4W POLE INSTALL Estimate Type:GO Contractor.H ENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30250619 Required Date: Oracle Project#:8004473 Estimated On: 03/02/2018 CU Detail Station: 01 350 10TH ST, Build Transkr Pernaln In Place Remove C.2/OP 50 G3W 1 G3W*2 1 GY3 1 GY3*5 1 HANDDIG 5 P.35/4W 1 S4 1 S4*2/0 1 Station: 2 351 1 OTH ST Build Transfer Remain In Place Remove CUT 3 DAI F-5 1 DA1 F-5*2 I DGAC 1 DGAC*25 1 G1W 1 G1W*2 1 P.45/3W 1 RUBUP 2 S20ES*2/0-1/0 1 S4 1 S4*2/0 1 S9 1 S9*1/0 4 S9*2 2 EYENUT 2 NUMBER 1 P.45/3W 1 PIN 1 POLECON 4 PRIINS 1 RUBDOWN 2 SEC 2 CUE Reports Estimate Number:32756 350 10TH ST.35/4W POLE INSTALL Estimate Type;GD Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30250619 Required Date: Oracle Project#:8004473 Estimated On: 03/02/2018 SECINS 2 SMWEDGE 4 STANDOFF 1 WOODGRD 1 CUE Reports Estimate Number:32756 350 10TH ST.3514W POLE INSTALL Estimate Type:GD Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#fTask:30250619 Required Date: Oracle Project#:8004473 Estimated On: 03/02/2018 Material Summary Item Quantity Item Number Item Description 2 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZED 10"X 8'X 1-1/4", SHIP ON OPEN FLATBED ONLY! 2 ARRL1003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER POLE (MOV)WITHOUT MOUNTING BRACKET, 15.2/26.4Y NOMINAL VOLTAGE 2 BKTAC009 BRACKET, ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM MATERIAL OVER ROD TYPE: SINGLE PHASE 2 BKTFS001 BRACKET, FIBERGLASS STANDOFF, 2" FIBERGLASS ROD, 18" STANDOFF TO INS BASE ROD COVERED WITH RAYCHEM HEAT- SHRINK MATERIAL, DUCTILE IRON FITTINGS 2 BOLDA015 BOLT, 3/4"X 14", DOUBLE ARMING, GALV. WITH 4 SQUARE NUTS ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 2 BOLMS020 BOLT, MACHINE, 5/8"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 50 EACH) 7 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 2 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 50 CA10SO02 CABLE,2/0(PAP), OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX CABLE"MESA VERDE" PRE-ASSEMBLED PARALLEL SOUTHWIRE61- 28-96-1, 1500 FOOT REELS 4 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" I CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE:#6-2/0 2 CLASS004 CLAMP, STRAIGHT STRAIN,ALUMINUM, 5000#, 4-3/0 ALUM 2 CLATGO01 CLAMP, TRANSFORMER TANK GROUND, "BRONZE"6 SOL- 1 STR4 12 CNNCP002 CONNECTOR,#2, 6-2 MAIN, 2-1/0 TAP, ALUMINUM COMPRESSION, PARALLEL TAP, 10 CNNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 1 CNNCP005 CONNECTOR,#3, 6-2 MAIN, 2/0-3/0 TAP, COMPRESSION, PARALLEL TAP,ALUMINUM, 4 CNNGRO02 COUPLING, GROUND ROD, "THREADLESS" REMARKS: FOR THREADLESS GROUND RODS 3 CNNTS009 CONNECTOR, CONTAMINATED ENVIRONMENT,TRANSFORMER SECONDARY SET SCREW TYPE WITH INHIBITOR, 1/2"STUD, RANGE: 12-350, 6-PORTS. 10 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 68 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON PLASTIC REEL,4" X 11.5"W/2"HOLE 280 COBCW014 CONDUCTOR, #4,TYPE 40 DSA, COPPERWELD &COPPERWELD- COPPER .204"DIAMETER 1480#BREAKING STRENGTH (50#COIL- 427' ) 20 COVIC002 COVER, "D"DIE, INSULATING,2-1/2" JEA CUE Reports Estimate Number:32756 350 1 OTH ST.35/4W POLE INSTALL Estimate Type:GD Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30250619 Required Date: Oracle Project#:8004473 Estimated On: 03/02/2018 2 CUTOT006 CUTOUT, CONTAMINATED ENVIRONMENT, 26" LEAKAGE DISTANCE TOGROUND, 100A,27KV, 170KVBIL (54EAPERPALLET) 1 FUSOH022 FUSE, OVERHEAD DISTRIBUTION, 1.6 AMP, TRANSFORMER 4 GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 2 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL 3/8"AND 7116" GUY STRANDS (DISTRIBUTION) 2 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE,20,000 LB MIN. ULT. STRENGTH. FOR WOOD OR CONCRETE POLES 4 GUYGRO01 GRIP, GUY, 3/8", 26", GALVANIZED 100 GUYST005 STRAND, GUY, 3/8"DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS "B" GALV. OR BEZINOL IS ACCEPTABLE (500-COIL) 1 INSGS002 INSULATOR, STRAIN, GUY BREAKER, 21,000#RATED, 60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 4 INSSU002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 2 INSVP001 INSULATOR, VERTICAL POST,TIE TOP 35-KV, 3/4"STUD TAP STANDARD PACKAGING IS NOT TO EXCEED THREE UNITS OR 72 POUNDS. 4 NUTSI-003 NUT, LOCK, SQUARE, 5/8" HOLE SIZE, HOT DIPPED GALVANIZED 4 NUTSI-004 NUT, LOCK, SQUARE, 3/4"BOLT SIZE, HOT DIPPED GALVANIZED 1 POLWO003 POLE, WOOD, 35'CLASS 4 (T/L 44), WEIGHT=1,026 LBS 1 POLWO006 POLE, WOOD, 45-CLASS 3 (T/L 26), WEIGHT=1,770 LBS 8 RODGRO03 ROD, GROUND, THREADLESS, 5/8"X 8', SHIP ON OPEN FLATBED ONLY! 2 SLEAL002 SLEEVE, ORANGE TO ORANGE NEUTRAL 4-4 ALUMINUM TRIPLEX NEUTRAL SPLICING 4 SLEAL003 SLEEVE, RED TO RED NEUTRAL 2-2 ALUMINUM TRIPLEX NEUTRAL SPLICING 2 STUL1001 STUD, LINE POST, DIA. SHANK-3/4", SHANK LENGTH- 1-3/4", GALVANIZED STEEL W/NUTS AND WASHERS; 3/4" HEAD SIZE 2 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5"HIGH X 2" WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 1 TIEPRO01 TIE, PREFORMED LINE,#2 AAAC,23" MIN. LENGTH, 7"NECK, SIDE TIE .316"-.357"COND. RANGE 1 TRAC0001 TRANSFORMER, 25 KVA, 14760/25565Y VOLT PRIMARY, 120/240 VOLT SECONDARY, SINGLE PHASE,CONTAMINATED ENVIRONMENT 4 WASRD004 WASHER, ROUND, 5/8" BOLT SIZE X 1 3/4"DIAMETER, GALVANIZED, 650 EA P/BOX) 19 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X 2"DIAMETER, GALVANIZED, 500 EACH PER BOX*** 11 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4", 5/8"X 3/4"BOLT SIZE, GALVANIZED 7 WASSP002 WASHER, SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED (EXTRA HEAVY DUTY) CUE Reports Estimate Number:32756 350 10TH ST.35/4W POLE INSTALL Estimate Type:GD Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30250619 Required Date: Oracle Project#:8004473 Estimated On: 03/02/2018 CU Summary CuNgme Quantity Description C.2/OP 50 2/0 AAC PAP W/2/0 AAAC NEUTRAL CUT 3 CUT POLE OR CROSSARM DA1 F-5*2 1 2 TANGENT TO 10 DEGREE ANGLE-UNSHIELDED, CONTAMINATED DGAC*25 I TRANS; CI, 26AKV 120/240 25KVA GIW*2 1 WOOD POLE- EQUIPMENT GROUND G3W*2 1 WOOD POLE-NON-EQUIPMENT GROUND GY3*5 1 GY3*5 3/8"DOWNGUY W/8 FT SCREW ANCHOR HANDDIG 5 NO DESCRIPTION... P.35/4W 1 35 FT.CLASS 4 WOOD POLE P.45/3W 1 45 FT. CLASS 3 WOOD POLE RUBLIP 2 LINE RUBBER INSTALLATION, PER SECT. S20ES*2/0-1/0 1 S20ES*2/0-1/0 S4*2/0 2 SECONDARY DEADEND S9*11/0 4 SECONDARY SPLICE S9*2 2 SECONDARY SPLICE -,,ON I I RX A- mow CU Name Quantity Description EYENUT 2 EYENUT REMOVAL NUMBER 1 POLE TAG REMOVAL P.45/3W 1 45 FT. CLASS 3 WOOD POLE PIN 1 INSULATOR PIN REMOVAL POLECON 4 S20 REMOVAL PRIINS 1 PRIMARY INSULATOR REMOVAL RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT. SEC 2 SEC. SPOOL INS. BRACKET REMOVAL SECINS 2 SEC. INSULATOR REMOVAL SMWEDGE 4 SMALL SEC.WEDGE CLAMP REMOVAL STANDOFF 1 PRI. INSULATOR STANDOFF BRACKET REMOVAL WOODGIRD 1 WOOD POLE NON-EQUIP. GIRD REMOVAL