341 11TH ST - ROOF r -jr.,
-LTJ ,,.
st CITY OF ATLANTIC BEACH
; , 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
''''!•011 9r INSPECTION PHONE LINE 247-5814
ROOF NON SHINGLE -
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: ROOF18-0025
Description: torch down re-roof FL5680.1 & FL13857.4
Estimated Value: 9600
Issue Date: 3/23/2018
Expiration Date: 9/19/2018
PROPERTY ADDRESS:
Address: 341 11TH ST
RE Number: 170105 0000
PROPERTY OWNER:
Name: STEIN DEBRA A
Address: 341 11TH ST
ATLANTIC BEACH, FL 32233-5531
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
,
Phone:
Name: ROMANO BROTHERS ROOFING, INC
Address: 155 E. Levy Road QA DANIEL JOSEPH ROMANO
Atlantic Beach, FL 32233
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions
applicable to this property that may be found in the public records of this county, and there may
be additional permits required from other governmental entities such as water management
districts, state agencies, or federal agencies.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
01,A. City of Atlantic Beach APPLICATION NUMBER
Js tt Building Department (To be assigned by the Building Department.)
800 Seminole Road {� r,11 v _ �O
w -� Atlantic Beach, Florida 32233-5445 C—(,�V o
• Phone(904)247-5826 • Fax(904) 247-5845 3 I s I J g
��,1 0r E-mail: building-dept@coab.us Date routed:
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 3"i I I I S4 - -1a•k1 - - review required Yes No
C Building
Applicant: 1---ori Q(1 Q &DS - kOp -) (\,0 Planning &Zoning
,, c Tree Administrator
Project: ' D(C, V\-- a c��-Jn ra -rot) r Public Works
Public Utilities
Public Safety _ _
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By _
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: 4proved. IN'6nied. ❑Not applicable
(Circle one.) Comments:
BUILDI ) 3l 81240Q/
(y--
PLANNING &ZONING Reviewed by: 7 , ' Date:
TREE ADMIN. Second Review: <proved as revised. ❑Denied. ['Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES j
PUBLIC SAFETY Reviewed by: rilo Date: 3I1/2o1r
FIRE SERVICES Third Review: I 'Approved as revised. ['Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
- 1..- -1-''''j
CITY OFAtlantic ATLANTBeach,FIClorBEACHida32233
'' 800 Seminole Road
ww,x
REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COMMENTS
V
Date . ( q I 1 Revision to Issued Permit Corrections to Comments Permit 1 - D.D. S.
Project Address 1(-inr
Contractor/Contact Na c r u s l.3D i/"\c
1
Phonb DLN D Li L. - l�,' Email fo li.. C IN, 6r04.113 ISri]t,��nc1 ®C1 LLA rt. `.eD \n
Description of Proposed Revision /Corrections: ` Permit Fee Due $
0 Ic r 49 .3i 1,-._ I & t / -p( pr.ei - n - SI C D lc
i q41 - i
Additiona crea in Building yalue $ Additional S.F. C). 00
By si 'ng bel w D/-.A c e __1( sI n affirm the Revision is inclusive of the proposed changes.
(printed name)
-\ \ • q . I I!)
ignature o actor/Agent(Contractor must sign if increase in valuation) Date
(Office Use Only)
Approved Denied Xe.-- Not Applicable to Department
Revision/Plan Review Comments 0v4 'led 1 ,-t D✓Iro 4 A c/` /i•i k
.1,111
ca//id 0 5'pokt 40 k,
Department Review Required:
Buildin
an g-&-Zoning eviewed By
Tree Administrator
Public Works 3/ I,L- .20
Public Utilities
Public Safety Date
Fire Services
'l `r
r', t CITY OF ATLANTIC BEACH
800 Seminole Road
` �.. Atlantic Beach,Florida 32233
6J f
xf r.i-$i
REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS
Date 3 l� Revision to Issued Permit Corrections to Comments Permit#R oof= 18 -a 0?—5
Project Address 3 ii \
Contractor/Contact Name O L t r.0 0 S
Phone (eiD1-1) aLitp • 'LiC1 Email
Description of Proposed Revision/Corrections: Permit Fee Due $ a O d
Nvc r n , r' i f' r �Vl �C
Additional Incr e in ilding Value $ Additional S.F.
y signing be w,I l o,k: 30 C it-Jai affirm the Revision is inclusive of the proposed changes.
(printed name)
Signature of Contra T /A nt(Contrac of must sign if increase in valuation) Date
(Office Use Only)
Approved V Denied Not Applicable to Department
Revision/Plan Review Comments
Department Review Required:
Building in
.i s is : Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities 3420/20/ �y)2oi b
Public Safety Date
Fire Services
I CITY OF ATLANTIC BEACH
. 800 SEMINOLE ROAD
'j µ" ATLANTIC BEACH,FL 32233
(904)247-5800
4p;319 f.
BUILDING REVIEW COMMENTS
Date: 3/8/2018
Permit#: ROOF18-0025 Site Address: 341 11TH ST
Review Status: Peru.ed RE#: 170105 0000
Applicant: ROMANO BROTHERS ROOFING, INC Property Owner: STEIN DEBRA A
Email: romanobrothersroofing@gmail.com Email:debra.a.stein@gmail.com
Phone: 9042465649 Phone:904.742.3694
THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS.
Revisions may not be submitted until ALL departments have completed their respective reviews.
Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a
few correction items will not be accepted.
Correction Comments:
1. Product approva113857.4, Quick-Stick Ice and Water Sand, according to Miami-Dade Building Code
Compliance Office Product Control Division,Notice Of Acceptance, under APPROVED
ASSEMBLIES,under Surfacing: Approved Roof Assemblies. See Limitation#3.
3. Quik-Stick Ice & Water Sand, Quik-Stick Ice & Water, or Quik-Stick HT Pro underlayments may be used in asphalt
shingles,metal panels,wood shakes and shingles and quarry slate roof assemblies. Quik-Stick Ice&Water Sand,Qui.
Stick Ice&Water,or Quik-Stick HT Pro underlayment shall not be used as roof tile underlayment.
2. Submit a compliant base sheet for the torch down roof system. Include the product approval and
installation instructions. The above product does not mention torch down roof assembly as an approved
assembly.
3. Submit the manufacturer's installation instructions from the Trinity/ERD documents/Evaluation Report.
This consist of 86 pages. The Building Department only want those pages submitted that pertain to this
site specific installation. Those pages submitted shall be highlighted to show to show specific
information for this roof cover installation. 2 copies.
Building
Mike Jones
Building Inspector/Plans Examiner
City of Atlantic Beach
800 Seminole Road
Atlantic Beach, FL 32233
904.247.5844
Email:mjones@coab.us
&Tut tied n4v1.4 t,, court wti 11 3/Pepi f? fJ
Resubmittal Notes:
Building •
Permit Application U dated 12/8/17
' ` r s FACE COPY COCity of Atlantic Beach , 2018
800 Seminole Road,Atlantic Beach,FL 32233
Phone:(904)247-5826 Fax:(904)247-5845
Job Address: ail 1 114 1:).?'1. p.Permit Number: 0 o P t ¶ OOas
Legal Description rj-Uri IL?. a5-Qc1E P--e) \-0 4- o--23\ \4. RE# r\ IC-`r. -paw
Z 'I
Valuation of Work(Replacement Cost)$ q L,C)0 Heated/Cooled SF 3.4 Non-Heated/Cooled
• Class of Work(Circle one): New Addition Alteration Repair • - De • .•ol Window/Door
• Use of existing/proposed structure(s)(Circle one): Commercial ' -
• If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A
• Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal j
escribe in detail the type of work to be performed:
Le--r Do -t Of G-,rI K.4)r22.0 n S4,i c_x 13 6 1. Li
Florida Product Approval# T") 5(..,, j. 1 for multiple products use product approval form
'ro•ert Owner Information
6A' ame: -„ 4 — (n Address: . V H
( I 41.-. S't- L r
/.# ity A si 6 TQC State i Zip ZZ 33 Phone 4,l7 l{ - 14 Z— . q((-
E-Mail 4 eorA ,A- , &-fei ne v'l04., I (0 c)yr
Owner or Agent(If Agent,Power of Attorn ency Letter Required)
Contract form• ion ((�' ��
Name of Compa ,,._ ib, ,/ , b 1..C% Qualifyi Agent: G n 1 _A
Address LP • G --ftCity State Ai Zip 5!I t
Office Phone L.i. h •'N__,.., Job Site/Contact Number ri..A .- l o um
State Certification/Registration#CC .)3Q (LQ3 E-Mail
Architect Name&Phone#
Engineer's Name&Phone# `
Workers CompensationL )gyp► o,,�ciQe. -Li 3Lt) 0 y I k`' i t,
t..-.1C_' 10- tom.
. 6'b, , Exempt/Insurer/Lease Employees/Expir ion Date
Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg
construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc.NOTICE:In addition to the requirerftents of this i ,
1ermit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and It!!
• here may be additional permits required from other governmental entities such as water management districts,state agencies,or !c!ti2
-deral agencies. N H o`N
• )WNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all 175 n.1 e
N
c.4 nz ,pplicable laws regulating construction and zoning. z c o
03?-).2-,,2ARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY iz2,
N3. Er
a .o 'ESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND ae•Nt
N j C N
NN 8d Fc d 0 OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ' ATTORNEYnal per1,0 ;
_coT 'E O: 'ING Y*UR NOTICE OF COMMENCEMENT.
ilk IOW il/
4„,„Iii,,.. _-,______
7
„„. (Signature of Owner or Agent) (Signature of Contractor)
(including contractor)
Signed and sworn to(or a • before meet ys day of Signed and sworn to(or aff •-• before e this s day of
�l 4{C-4"1 , .1 u by UwL1-- J ---[� , V�1 G I C..+ , Lk )Ve. ,by C rx _ -- b It..
_.1"...10.0– __
-...0111111.111111111111111-11 ..II
ture of Notary) -Z --
[ ]Personally Known OR [�]Personally Known OR
Q�j Produced Identification [ ]Produced Identification
Type of Identification: Type of Identification:
OFFICE COPY - .11 I ks.1,h 5.t.
,0,,....,
(.6- TRINITY' ERD
TABLE 1A:WOOD DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER
System Deck Base insulation Layer Top Insulation Layer Roof Cover(Note 14)
No. No . - -
MDP(psf)
Type ' Atta Type Attach Base my _. Cap
Min. • 2-Inch Min.1.5-Inch
W-1. plywood or OSB at max. EnergyGuard RA, Min.0.5-inch Structodek High (Optional)One or more
EnergyGuard RH, GAF 2-Part Density Fiberboard Roof GAF 2-Part BP-AA,SBS-AA BP-AA,SBS-AA,SBS-TA SBS-AA,5B5 TA or
24-inch span -52.5
EnergyGuard RN Insulation or APP TA APP-TA
Min. 3Z-Inch Min.1.5-Inch Min,0.25-Inch Dens Deck,
—
W-2. plywiSB at max. EnergyGuard R,1, Dens Deck Prime or BP-AA,SBS-AA,SOS-
BP-AA,
One or more
EnergyGuard RH, GAF 2-Part SECUROCI(G sum-Fiber GAF 2-PartBP-AA,SBS-AA,SOS-TA SBS-AA,SBS-TA or -52.5
24-Inch span Gypsum-Fiber TA or APP-TA or APP-TA APP-TA •
EnergyGuard Rt( Roof Board t°
h Min,1,5-inch Min.0,25-Inch Dens Deck,
W-3, plywood or at max. EnergyGuard RA, E<PFI e or WeatherWatch XT
EnergyGuard RA, GAF 1-Part `'r... GAF 2-Part Mat Surfaced Leak (Optional)SBS-TA,App-
24-inch span w_,,. .. - yASum er TA
SOS-TA,APP-TA -52.5
•,,. EnergyGuard RN Roof Board Berner
TABLE 1B-1: WOOD DECKS—NEW CONSTRUCTION oR REROOF(TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Deck Anchor Sheet Base Insulation
No. Top Insulation Roof Cover(Note 14) MDP
(Note ti Type Fasteners Attach Type Attach
CONVENTIONAL SYSTEMS: TVPe Attach Base Ply Cap (psf)
Min.1-Inch Min.0.5-inch
GAFGLAS#75 Base Sheet, 32 8-inch o,c.at EnergyGuard Polyiso Structodek High
Min.15/32- gin 1 min.4-inch laps Insulation, Density Fiberboard
Inch Tri-Ply#75 Base Sheet, 5/8-inch dia. (Optional)
W 4• plywood at GAFGLAS#80 Ultima Base tin caps with and 8-inch o.c.In EnergyGuard Ultra Hot Roof Insulation or 8P•AA SBS-AA
max.24-
spaced,
GAFGLAS Stratavent 11 ga. two,equally Polyiso Insulation or EnergyGuard Perlite Hot BP-AA,S8S-
spaced, Ener Guard RH asphalt asphaltSBS-AA, SBS-TA, -45.0
Inch span Nailable Venting Base annular ring EnergyGuard P Recover Board or Min. AA SBS-TA, APP-TA
P Sheet,Ruberold 20 Smooth shank nails staggered center Polyiso or min.1.5- 0,75-Inch EnergyGuard APP-TA
rows Inch EnergyGuard RA Perlite Roof insulation
-
or EnergyGuard RN (homogeneous)
MIn.1-Inch
Min.15/32- GAFGLAS#75 Base Sheet, 32 ga.,1- 8-inch o.c.at EnergyGuard Polyiso
Inch
Tri-Ply#75 Base Sheet, 5/84inch dia.15/32-
min. laps Insulation, (Optional)
GAFGLAS#80 Ultima Base and 8-inch o.c,In EnergyGuard Ultra Min.0.25-Inch Dens
W-5. plywood at tin caps with Hot Deck Prime or Hot BP-AA,SBS- BP-AA, SBS-M,
max.24-
spaced,
GAFGLAS Stratavent 1185. two,equally Polyiso insulation or asphalt SECUROCK Gypsum- asphalt AA,SBS-TA, SBS-AA, SBS-TA, -45.0
Inch span
Nallabie Venting Base annular ring spaced, EnergyGuard RHAPP-TA 585-TA, APP-TA
Sheet,Ruberold 20 Smooth shank nails staggered center Polyiso or min.1.5- Fiber Roof Board
rows Inch EnergyGuard RA APP TA
or EnergyGuard RN
Exterior Research and Design,LLC.d/b/a Trinity)ERD
Certificate of Authorization 49503 PBC NON-1-1V1-12 EVALUATION;GAF Modified Bitumen Roof Systems Evaluation Report 01506.11.04-R18 for FL5680-RI8
Prepared by: Robert Nleminen,PE-59166 GAF;(800)766-3411 Revision 18:04/12/2017
Appendix 1,Page 5 of 85
'fir
{
APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE „ ~I T I IIERD
Table Deck Application
Type Description
1A Wood New, Reroof(Tear-Off)or Recover C Mech.Attached Insulation, Bonded Roof Cover Page
18 Wood New, Reroof(Tear-Off) or Recover p 2
Insulated, Mech.Attached Base Sheet, Bonded Roof Cover
2
1C-1 Wood New or Reroof(Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
1C-2 Wood New, Reroof(Tear-0 or Recover E 2
Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
3
The following notes apply to the systems outlined herein:
1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented t
proper codified and/or FBC Approval documentation.
hrough
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following
engagements:
> Wood Deck: OMG #12 or #14 HD with OMG 3 in. Galvalume Steel Plate or Tru-Fast DP or HD with MP-3 Plates. Minimum 3/4-Inch
penetration or minimum 1-inch wood plank embedment. /a Inch plywood
3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard
DensDeck DuraGuard, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and is
documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.8, when installed with the roof cover, perlite, DensDeck, Densbecl< Prime,
4. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
5, For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure
determined In accordance with FBC Chapter 16, and no rational analysis is permitted.
6. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design
professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or
ANSI/SPRI FX-1. g
7. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond
performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting
satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52pANSI/SPRI9IA-pressures on
I or TAS 124 its
own merit to the
8, "MDP"= Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609.1.5 for
determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity IERD
Certificate of Authorization#9503 Evaluation Report Date of Issuance:.12.11 for 2/09/2FL948 -R1
Prepared by: Robert Nieminen, PE 59166
of 12/09/2011
Appendix 1, Page 1 of 3
it '... _ i
'\.,i TRIM 1 6 !ERD
TABLE 1A: WOOD DECKS—NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULA.T YON, BONDED ROOF COVER
System Base Insulation Top Insulation Layer
Roof DeckNo. Layer Roof Cover
Type Fasteners 1111=211 Base Ply Cap MOP(psf)
Min. 19/32"plywood at (Optional)One or Min. 3/8 inch
W-1 11111
max.24"spans attached more layers,any SECUROCI<Gypsum- See Note 2 1 z
with Sd common or ring combination,loose Fiber Roof Board per 1 ft EasyBase (Optional) EasySticl'<Plus
shank nails,6"o.c. laid EasyBase
TABLE 1B: WOOD DECKS—NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
SYSTEM TYPE 0: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Insulation Layer Base Sheet
No. Roof Deck Roof Cover
Type Attach Type Fasteners
Min. 19/32"plywood at plyMIZE MOP(psf)
W-2 max. 24"spans attached Any type, 10-Inch o.c. In the min.4-
with 8d common or ring thickness or Loose laid EasyLay See Note 2
Inch lap and 10-Inch o.c.In
shank nails, 6"o.c, combination two, equally spaced, EasyBase EasySttck Plus -60.0
staggered center rows
TABLE iC-1: WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System Roof Deck
No. Roof Cover
Type Fasteners Attach MDP(psf)
Min. 19/32"plywood at max.24" and min. 32 12 ga. annul9ra./ 1-5/8'Ing shank nails 7-Inch o.c. In the 4-Inch lap and 7-
W-3 spans attached with 8d common EasyLay
nails,6"o.c, diameter tin-caps. (Ref: FBC Inch o.c.in three, equally spaced, EasyBase EasySticl<Plus -45.0
1517.5) staggered center rows
Min. 19/32"plywood at max.24" 12 ga. annular ring shank nails
W-4 spans attached with 8d ring EasyLay and min. 32 ga., 1-5/8" 7-Inch o.c.In the 4-Inch lap and 7-
diameter tin-caps. (Ref: FBC inch o.c.In three,equally spaced, EasyBase Eas Stick Plus -60.0
shank nails, 6"o.c. 1517.5) staggered center rows y
Exterior Research and Design, LLC.d/b/a TrinitylERD
Certificate of Authorization#9503 Evaluation Report Date of Issuance:.12.11 for 2/09/2-R1
Prepared by: Robert NIeminen, PE-59166 of 12/09/2011
Appendix 1, Page 2 of 3
--u.
�`.., ', t TRINITY!ERD
TABLE 1C-2: WOOD DECKS—NEW CONSTRUCTION, REROOF(Tear-Off)or RECOVER
SYSTEM TYPE-E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF
System
No. Roof DeckCOVER
Type Fasteners Roof Cover
in
Min. 19/32"plywood at max.24" �
spans attached with 8d common See Note 2 10-Inch o.c. In the min. 4-1nch lapCap MDP(psf)
or ring shank nails, 6"o.c. o.c.In two,equally spaced,staggered center0lh
rowsEasyBase EasyStick Plus
-60.0
TABLE 1D: WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE F: BONDED ROOF COVER
System
No. Roof Deck Roof Cover
11111r -
Cap MDP(psf)
x
75.0 psf
Exterior Research and Design, LLC.d/b/a TrfnityIERD
Certificate of Authorization #9503
Prepared by: Robert Niemen, PE-59166 Evaluation Report Date of 1.12.11 for 2/09/2 FL9487-R1
of Issuance: 12/09/2011
Appendix 1,Page 3 of 3
1").-
N.
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
TRINITY ERD 353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Tarco Roofing Evaluation Report 10880.07.08-R9
One Information Way,Suite 225 FL10450-R9
Little Rock,AR 72202 Date of Issuance:07/11/2008
(254)913-7750 Revision 9:10/03/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Tarco Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity'ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert 1.M.Nieminen,P.E. %°s-:',�,icr%<c The facsimile seal appearing was authorized by Robert Nieminen,
Florida Registration No.59166,Florida DCAANE1983 ' ` `'^
(JF,ter^,\a�. P.E.on 10/03/2017.This does not serve as an electronically signed
L
``�'�•'ru;rN,s document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity'ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity'ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Tarco Roof Underlayments,as produced by Tarco Roofing,have demonstrated compliance
with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set
forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2011
1507.1.1,T1507.1.1 Physical Properties ASTM D226 2009
1507.1.1,T1507.1.1 Physical Properties ASTM D4869 2016
1507.1.1,T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.2.9.2 Physical Properties ASTM D3909 2012
1507.2.9.2,FRSA/TRI April 2012 Physical Properties ASTM D6380 2013
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
FRSA/TRI April 2012 Physical Properties ASTM D6164 2011
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) FRSA/TRI April 2012(04-12) T33190.08.10 08/06/2010
ERD(TST6049) ASTM D1970 T32530.08.10 08/17/2010
ERD(TST6049) ASTM D1970 T30160.08.09-R1 10/12/2010
ERD(TST6049) FM 4474 T37610.07.11 06/29/2011
ERD(TST6049) ASTM D3909 T40780.04.12 04/06/2012
ERD(TST6049) ASTM D6380 T40790.04.12 04/06/2012
ERD(TST6049) ASTM D6164 135410.04.12 04/18/2012
ERD(TST6049) ASTM 01970 T45250.04.13-R2 04/23/2013
ERD(TST6049) FRSA/TRI April 2012(04-12) T43930.09.13-R2 09/11/2013
ERD(TST6049) ASTM D226&D4869 SC4950.02.14-R2 06/25/2014
ERD(TST6049) ASTM D1970 TAR-SC9480.15 07/02/2015
ERD(TST6049) FM 4474 TAR-SC8020.14 12/03/2015
ERD(1516049) FM 4474 TAR-SC5670.03.16 03/21/2016
ERD(TST6049) FM 4474 T6460.06.07-R2 05/26/2017
ERD(TST6049) ASTM D226 TAR-SC13965.02.17-R1 05/17/2017
ERD(TST6049) FBC 1507.1.1(Exception) TAR-SC16115.17 10/02/2017
ERD(TST6049) FRSA/TRI April 2012(04-12) TAR-SC16115.17 10/02/2017
PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003
PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003
PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004
PRI(TST5878) ASTM D226 TOT-015-02-02 05/24/2004
PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004
PRI(TST5878) ASTM D4869 TOT-009-02-02 09/14/2004
PRI(TST5878) ASTM D226 TOT-041-02-01 05/24/2006
Miami-Dade(CER1592) FBC HVHZ Certification 16-1116.09 01/12/2017
Tarco Roofing Adhesive compound Affidavit 12/15/2015
UL,LLC.(QUA9625) Quality Assurance Service Confirmation Exp.06/28/2020
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 2 of 10
TRINITY ERD
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlayments:
LeakBarrier MS300 Ice and Water Armor is a self-adhering, glass mat reinforced, mineral surfaced, SBS
modified roof underlayment; meets ASTM D1970.
LeakBarrier P• 5200HT Ice and Water Armor is a self-adhering, glass mat reinforced, fabric surfaced, SBS
modified roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12).
LeakBarrier P• 5200Mu Ice and Water Armor is a self-adhering, glass mat reinforced, smooth poly film
surfaced,SBS modified roof underlayment;meets ASTM D1970.
LeakBarrier NR500HT is a self-adhering,plastic film surfaced,modified underlayment;meets ASTM D1970.
LeakBarrier S• S400 Ice and Water Armor is a self-adhering, fiberglass reinforced, smooth surfaced
modified underlayment;meets ASTM D1970.
4.2 Mechanically Fastened Underlayments:
Tarco 15 is an asphalt-saturated organic felt;meets ASTM D226,Type I.
Tarco 30 is an asphalt-saturated organic felt; meets ASTM D226,Type II.
Tarco NO 30 is an asphalt-saturated organic felt;meets ASTM D4869,Type II.
LeakBarrier EasyLay is an asphalt-coated polyester fabric roof underlayment; meets physical
requirements of ASTM D226,Types I and II.
4.3 Mechanically Fastened and/or Bonded Underlayments:
Fiberglass Mineral Surfaced Roll Roofing is a glass-fiber-reinforced, asphalt-coated, granule surfaced
underlayment used as a valley liner;meets ASTM D3909.
ASTM Organic Mineral Surface Tile Underlayment is an asphalt-saturated organic roll roofing sheet;
meets ASTM D6380,Class M.
LeakBarrier EasyMopT"SBS is a polyester reinforced,SBS modified bitumen roofing underlayment; meets
FRSA/TRI April 2012(04-12).
4.4 Mechanically Fastened Base Sheets:
LeakBarrier E• asyLay UDL 15 consists of a woven-polymeric scrim with a textured fabric on the top
surface; meets FBC 1507.1.1(Exception). Within this Evaluation Report, it is used as a base sheet in multi-
ply underlayment systems. See FBC File No.FL16884 use as a stand-alone roof underlayment.
LeakBarrier' E• asyLay UDL Basic consists of a woven-polymeric scrim with a textured fabric on the top
surface; meets FBC 1507.1.1 (Exception). Within this Evaluation Report, it is used as a base sheet in multi-
ply underlayment systems. See FBC File No.FL16884 use as a stand-alone roof underlayment.
LeakBarrier E• asyLay" UDL 50 consists of a woven-polymeric scrim with a non-woven fabric on the top
surface and a rubberized polymeric coating on the back surface; meets FBC 1507.1.1 (Exception). Within
this Evaluation Report, it is used as a base sheet in multi-ply underlayment systems. See FBC File No.
FL16884 use as a stand-alone roof underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization 119503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 3 of 10
CTRINITY ERD
5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Asphalt Wood Shakes
Underlayment Shingles Nail-On Tile Foam-On Tile Metal &Shingles Slate
LeakBarrier MS300 Yes No No No Yes Yes
LeakBarrier PS200HT Yes Yes Yes Yes Yes Yes
See 5.5.2
LeakBarrier PS200M" Yes No No Yes Yes Yes
LeakBarrier NR500HT Yes No No Yes Yes Yes
(No copper or zinc)
LeakBarrierSS400 Yes No No No Yes Yes
Yes Yes
LeakBarrier EasyLay Yes (as base sheet in (as base sheet in Yes Yes Yes
multi-ply system) multi-ply system)
LeakBarrier EasyLay UDL 15, Yes Yes Yes Yes Yes Yes
UDL Basic or UDL 50 (See FL16884) (as base sheet in (as base sheet in (See FL16884) (See FL16884) (See FL16884)
multi-ply system) multi-ply system)
Tarco 15 Yes No No Yes Yes No
Yes Yes
Tarco 30 Yes (as base sheet in (as base sheet in Yes Yes Yes
multi-ply system) multi-ply system)
Tarco NO 30 Yes No No Yes Yes Yes
Fiberglass Mineral Surfaced Yes
Roll Roofing Valley Liner per No No No No No
1507.2.9.2(2)
ASTM Organic Mineral Yes
No Yes No No No
Surface Tile Underlayment See 5.5.2
LeakBarrier EasyMop SBS No Yes Yes No No No
See 5.5.2
5.5.1 Tarco 15,Tarco 30,Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed
by a LeakBarrier self-adhering top layer or asphalt-applied ASTM Organic Mineral Surface Tile
Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top
layer underlayments.
5.5.2 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS1
Adhesive Florida Product Underlayments
Approval
ICP Adhesives Polyset®AH-160 FL6332 LeakBarrier PS200HT,ASTM Organic Mineral Surface Tile
Underlayment or LeakBarrier EasyMop SBS
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 4 of 10
TRINITY ERD
5.6 Allowable Substrates:
5.6.1 Direct-bond to deck:
LeakBarrier MS300, LeakBarrier PS200HT, LeakBarrier PS200mu, LeakBarrier NR500HT or LeakBarrier SS400
self-adhered to:
> New untreated plywood(unprimed or primed with ASTM D41 primer);
> Existing plywood(unprimed or primed with ASTM D41 primer);
> New or existing OSB(unprimed or primed with ASTM D41 primer);
> Structural concrete(unprimed or primed with ASTM D41 primer).
Note: Tarco does not require priming of new or existing plywood or OSB sheathing. New or existing
sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier membranes.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to:
> ASTM D41 primed structural concrete.
Note: Refer to Section 5.6.4 for uplift limitations associated with direct-deck underlayment installations
where the overlying roof cover is foam-on tile roofing.
5.6.2 Bond to Mechanically Attached Base Sheet:
LeakBarrier MS300, LeakBarrier PS200"T, LeakBarrier PS200"', LeakBarrier NR500"T or LeakBarrier SS400
self-adhered to:
> ASTM D226,Type I or II felt;
> ASTM D4869 felt;
> LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier
EasyLay UDL 50.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to:
> ASTM D226,Type I or II felt;
> ASTM D4601,Type II base sheet.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems,base layer shall be attached
per minimum requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1, or as listed in Section
5.6.4 herein,or as tested in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
LeakBarrier MS300, LeakBarrier PS200"T, LeakBarrier PS200"', LeakBarrier NR500111-or LeakBarrier SS400
self-adhered to ASTM 041 primed metal (flashing metal,valley metal,etc.)
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12)and are used in foam-on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for
determination of design wind loads.
#1 Maximum Design Pressure=-75.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction
Primer: (Optional)ASTM 041
Base Ply: (Optional)LeakBarrier PS200M",self-adhered.
Underlayment: LeakBarrier P5200"T,self-adhered.
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 5 of 10
TRINITY ERD
#2 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction
Primer: (Optional)ASTM D41
Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200MU or LeakBarrier EasyBase,
rolled into place to create continuous bond
Base Ply: (Optional)LeakBarrier PS200",self-adhered
Underlayment: LeakBarrier PS20011T,self-adhered.
#3 Maximum Design Pressure=-217.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)ASTM D41
Base Ply: (Optional)LeakBarrier PS200",self-adhered
Underlayment: LeakBarrier P52005T,self-adhered.
#4 Maximum Design Pressure=-45.0 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay UDL 15,LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50(48"wide
rolls);See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6"o.c.at the 4-inch wide side laps and 8"o.c.at three(3)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
#5 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 7"o.c.at the 4-inch wide side laps and 7"o.c.at three(3)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier PS200M",self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
#6 Maximum Design Pressure=-60.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay UDL 15,LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50(48"wide
rolls);See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6"o.c.at the 4-inch wide side laps and 6"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier PS200M',self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
#7 Maximum Design Pressure=-82.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8"o.c.at the 4-inch wide side laps and 8"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier P5200M',self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 6 of 10
TRINITY ERD
#8 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 4"o.c.at the 4-inch wide side laps and 4"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier PS200MU,self-adhered
Underlayment: LeakBarrier PS200HT,self-adhered.
5.6.4.1 All other direct-deck, adhered Tarco underlayment systems beneath foam-on tile systems carry a
Maximum Design Pressure of-45 psf.
5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
LeakBarrier EasyLay, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop SBS
shall not be left exposed for longer than 180-days after installation.
LeakBarrier PS200"T shall not be left exposed for longer than 120-days after installation.
LeakBarrier M5300, NR500"T, P5200Mu or SS400 shall not be left exposed for longer than 30-days after
installation.
Tarco 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for
more than 24 hours after installation could adversely affect performance.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12));
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
LeakBarrier PS200HT
Flat 10-tile stack or 6-tile stack(4 over 2) 6:12
Lugged 6-tile stack(4 over 2) 6:12
Flat 6-tile stack(4 over 2) 5:12
LeakBarrier EasyMop SBS
Lugged 6-tile stack(4 over 2) 6:12
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 7 of 10
TRINITY ERD
6. INSTALLATION:
6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco Roofing published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 LeakBarrier®MS300,PS200HT,P5200Mu,NR500HT or SS400 Ice and Water Armor:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
Cut to manageable sections and allow to relax prior to application.
Membrane Application:
➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend
approximately 3/8"over the eave and rake with the selvedge edge positioned upslope.
➢ Fold back the upslope half of the sheet and remove the exposed release film,taking care not to displace
the membrane
➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles
and ridges
➢ Apply a 1/16"thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3"
onto the deck surface.
➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the
substrate from the centerline out.
➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps
minimum 36".
➢ Remove selvage release film,if present,and install second and subsequent courses in a similar manner.
➢ Install capped or tin-tagged nails 6"o.c.along the centerline of the laps.
➢ At all T-joints,where an end-lap and the next overlapping course intersect,apply a bead of roofing laps
cement before the overlapping course is laid.
➢ Roll the entire surface with a weighted roller,paying particular attention to side laps,end laps and eave
/rake areas to ensure a complete bond.
6.3.3 Tile Applications(PS200"T only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self-adhering top
sheet(s),Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.6.4 herein.
Refer to Section 5.8 for tile staging limitations. If tiles are to be left in a staged condition for more than 30
days,Tarco Roofing requires tiles be staged two tiles perpendicular to slope, four tiles on top, parallel to
slope,regardless of the allowance in Section 5.8.
6.3.4 Multi-Ply Underlayment Systems:
LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor (direct-to-
deck per 5.6.1 or over mechanically attached base sheet per 5.6.2)is allowable for use under mechanically
attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not
a requirement, but is allowable if a multi-ply underlayment system is desired.
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 8 of 10
TRINITY ERD
6.4 Tarco 15 and 30:
6.4.1 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type I (Tarco 15)or ASTM
D226 Type II (Tarco 30) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be
installed.
6.4.2 Tile Applications(Tarco 30 only):
Tarco 30 is limited to use as a mechanically attached base sheet in the "Two Ply System"from FRSA/TRI
April 2012 (04-12). Reference is made to Table 1 herein, coupled with FRSA/TRI April 2012 (04-12)
Installation Manual.
6.5 Tarco NO 30:
6.5.1 Shall be installed in compliance with the codified requirements for ASTM D4869, Type II underlayment in
FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
6.6 LeakBarrier EasyLay:
6.6.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in
FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
6.6.2 Non-Tile Applications:
Place a full width section of EasyLay,parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay
lines facing up,and position to the edge of the eave and rake. Install a few fasteners at the top,near the
rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any
wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8"headed roofing nails or
1"capped (plastic or metal) nails, driven by hand or pneumatically,spaced 6"o.c.at all laps in the center
of the seam area,and two staggered rows fastened 12"o.c.in the field of the sheet. Install nails such that
the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to
avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down.
Align the next roll over the preceding sheet so as to form a minimum 4", water-shedding lap,and install
per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water-shedding
laps and minimum 8"end-laps,which are staggered minimum 36"fro the preceding course.
For double layer applications, follow the instructions noted above, but using a minimum 19", water-
shedding side lap.
Allow for minimum 6"up the vertical transitions and minimum 6"over hips and ridges.
At valleys,first install a vertical length of EasyLay down the center of the valley,then start at the low point
and work to the high point, rolling the membrane from the center outward in each direction,ensuring no
wrinkles or tears. Covered with valley-metal or other valley lining material in accordance with NRCA
recommendations.
Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred.
Seams or joints that require adhesive or sealant can be treated with high quality plastic cement(asbestos
free).
6.6.3 Tile Applications,base layer in multi-ply system:
LeakBarrier EasyLay is limited to use as a mechanically attached base sheet in the"Two Ply System"from
FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012(04-12)Installation Manual
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 9 of 10
TRINITY ERD
6.7 ASTM Organic Mineral Surface Tile Underlayment and LeakBarrierTM EasyMop SBS:
6.7.1 Shall be installed in compliance with current Tarco Roofing published installation requirements. For use in
tile applications:
✓ ASTM Organic Mineral Surface Tile Underlayment and LeakBarrierT" EasyMop SBS are for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from
FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically
fastened or adhered tile roof systems.
6.8 Tile Staging:
6.8.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. Refer to Table 2 herein,and Tarco Roofing published requirements for tile staging.
6.8.2 Battens and/or Counter-battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12)
must be used on all roof slopes greater than 7:12. Precautions should be taken as needed,such as the use
of battens or nail-boards, to prevent tile sliding and/or damage to the underlayment during the loading
process.
6.8.3 Tarco Roofing specifies the minimum cure time after installation of self-adhering membranes and before
loading of roofing tiles is forty-eight(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant Specification Product(s)
ASTM D226 LeakBarrier EasyLay,Tarco 15,Tarco 30
ASTM D4869 Tarco NO 30
ASTM D3909 Fiberglass Mineral Surfaced Roll Roofing
Greencastle, ASTM D6380 ASTM Organic Mineral Surface Tile Underlayment
PA LeakBarrier'MS300 Ice and Water Armor, LeakBarrier PS200M"Ice
ASTM D1970
and Water Armor,LeakBarrier SS400 Ice and Water Armor
ASTM D1970&FRSA/TRI 04-2012 LeakBarrier PS200HT Ice and Water Armor
FRSA/TRI 04-2012 LeakBarrier"EasyMop'"SBS
ASTM D226 LeakBarrier EasyLay,Tarco 15,Tarco 30
ASTM D4869 Tarco NO 30
Belton,TX ASTM D1970 LeakBarrier'MS300 Ice and Water Armor, LeakBarrier PS200MU Ice
and Water Armor,LeakBarrier SS400 Ice and Water Armor
ASTM D1970&FRSA/TRI 04-2012 LeakBarrier PS200Hr Ice and Water Armor
Coshocton,OH ASTM 01970 LeakBarrier NR500HT
Gujarat,India LeakBarrier EasyLay UDL 15,LeakBarrier EasyLay UDL Basic,
FBC 1507.1.1(Exception) LeakBarrier EasyLay UDL 50
9. QUALITY ASSURANCE ENTITY:
UL, LLC.—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R9
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments;(254)913-7750 Revision 9:10/03/2017
Page 10 of 10
NOTICE OF COMMENCEMENT
Permit No. 1 :90P/S'0e(3)S Parcel ID/Tax Folio No. .Th 1 lD. - DDD(
State of Florida, County of Duval OFFICE COPY
THE UNDERSIGNED hereby give notice that the improvement will be made to certain real property in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
1. Description of property(legal description of propgrty and adc ess if avails e):
2. GgereraiTyescriptipn of improvements:
rO(7
Owner Information:
0
a)Name and Address: te(2(' C `,^ 661-1 t 1 t-l.‘ Stri•E - 04-14 ,41' 661-al
R--
b) Interest in property:
c)Name and address of simple titleholder(if other than owner):
4. Contractor Informal
a)Name and Address: o c r ,� , ,.r
15 i• 3�
b) Phone Number: 011D-t- - ��� o�� C� 1
5. Surety Information:
a)Name and Address:
b)Phone Number:
c)Amount of Bond: $
6. Lender Information:
a)Name and Address:
b)Phone Number:
7. Person within the State of Florida designated by owner upon whom notices or other documents may be served as
provided by 713.13 (1)(a)7, Florida Statutes:
a)Name and Address:
b)Phone Numbers of Designated Person:
8. In addition to himself/herself, Owner designates of to receive a
copy of the Lienor's Notice as provided in Section 713.13 (1) (b),Florida Statutes.
a)Name and Address:
b)Phone Number of person or entity designated by owner:
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction
and final payment to the contractor,but will be one(1)year from the date of recording unless a different date is
specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE
NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I,
SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING
YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated
therein are true tobelief.
the best of my knowledge and
ogi / '
.,N
&
gnature o,wrier or Owner's Authorized Officer/Director/Part ner,'lan_ager Signatory's Printed Nmne Title/Office
V
The foregoing instrument was acknowledged before me this ) day of k----(a f C-a, , 201 g
by 1 k.r� n as for .
(Name of Person) (Type of Authority,i.e.Officer/Attorney) (Name of Party Instrument was Executed for)
- 1
synNotary Public State of Florida Y PUBLIC, STATE OF FLORIDA
Nicholas Joshua Brower A f'C!(�Q I qs
• 4 My Commission GG 181978 Print Name: 1 V E r oQ
.., Expires 02/01/2022
Doc#2018051060,OR BK 18302 Page 1926, ❑ P onally Known
Number Pages:1 dentification'Type: .D./ .
Recorded 03/05/2018 12:24 PM,
RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL
COUNTY Revised 1/18/18
RECORDING $10.00