350 OCEAN BLVD ROW CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD X ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROW1 8-0008 Description: construct 35-ft. class 4 pole &overhead service Estimated Value: 0 Issue Date: 3/27/2018 Expiration Date: 6/25/2018 PROPERTY ADDRESS: Address: 350 OCEAN BLVD RE Number: 1701770000 PROPERTYOWNER: Name: GALLOWAY CHARLES M Address: 350 OCEAN BV ATLANTIC BEACH, FL 32233-5336 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JACKSONVILLE ELECTRIC AUTHORITY Address: 21 CHURCH ST W 3RD FLR JACKSONVILLE, FL 32202 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. City of Atlantic Beach APPLICATION NUMBER Building Department 1'.F. (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 MAR 2 1 2016 00C Phone (904)247-5826 - Fax(904) 247-5845 E-mail: building-dept@coab.us L Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Department review required Yes__ No Building Applicant: &A Planning &Zoning Tree Administrator Project: SVIk 0 \J :S&4 LQ Q Public Utilities Public Safety Fire Services Review fee $ Dept Siqnature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [�fApproved. []Denied. []Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed TREE ADMIN. Second Review: DApproved as revised. F]Denied. E]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: F]Approved as revised. [:]Denied. FINot applicable Comments: Reviewed by: Date: Revised 05/19/2017 APPLICATION NUMBER City of Atlantic Beach eel Building Department (To be assigned by the Building Department.) 800 Seminole Road CW 9 Atlantic Beach, Florida 32233-5445 �AR 2 1 2MB Phone(904)247-5826 - Fax(904) 247-584 E-mail: building-dept@coab.us L Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 0(_Ut-iie� - Department review required Yes No Building Applicant: &, A Planning &Zoning Tree Administrator Project: 0,0��SV�k(_A Do "vu�d &0--i (_Publicv�tll � Public Safety Fire Services Review fee Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLJCATION STATUS Reviewing Department First Review: K/Approved. [:]Denied. [:]Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by-.—,?;t Date: TREE ADMIN. Second Review: []Approved as revised. F]Denied. F P msgWORKS Comments: ]Not applicable PUBLIC UTILIT17,,, I S- PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: [:]Approved as revised. []Denied. E]Not applicable Comments: Reviewed by: Date: Revised 05119/2017 RIGHT-OF-WAY EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach U PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address- 3-0 Ocea,,) L3 L,/. Phone 66f-�2723 Pertnittee 3-P-4 Email 6,'v"j? r (Oje,,q .I_Oej-? Requesting Permission to Construct _Cil 35 toss (� Laect I Role, ol- Stt,.ce Location(Reference to Cross-Street) Ll VL S y- • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works, any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of (Project Superintendent) with Company Name Phone 2 72-? • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation, as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within_days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be notified twenty-four(24)hours prior to starting work and again immediately upon completion. Date Permittee(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this_day of 20 by who personally appeared before me and (printed name of Pennittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. Personally Known Signature of Notary Public,State of Florida Produced Identification(Type) 16L Ipw .......... ... ---------- -"j-k All C2 tv vw 41, 41 fA Aim. lyw, Ok� Pr ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:33093 N.O.: 8004473 WO#: 30259596 CONST 03/20/18 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 563 REQ'D:NO CELL ENGINEER: Robert Simpson N.o.: N/A ZIP CODE: N/A CUSTOMER/ Svc PHONE LOCATION: 350 OCEAN BV./POLE INSTALL 563 CENTER: SSSC N.O.:665-7793 z' -0-3 STA 1. P# 348 OCEAN BV./ INSTALL n 0 35/4W RUN 2/OP TO STA 2, STA 2. P#359 OCEAN BV. 419 THIS IS FOR A NEW HOME 25A -,;:-��241 �b c;, 42 275 40, 75B 273 tj . 13 2/OP 2T TH ST 1/0-T 4/OP STA 2 rl z) STA I uj 4K)O 3 40, 331 rn 40, 50B 4W 03 331 25A 265 1�0 009, 301 tkj 40, t-j q2 1 50B all 303 4 OP 40, n c� 3RD --;2T 152 275 25C CUE Reports Estimate Number:33093 348 OCEAN BV./35'W POLE Estimate Type:SR Contractor.HENKELS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#1Task:30259596 Required Date: Oracle Project#:8004473 Estimated On: 03/20/2018 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $577.50 $577.50 2.Transformer Cost(w/sales tax) $0.00 $0.00 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $286.49 $758.50 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $200.00 $115.67 7.Engineering Costs(Variable%of line 4) $80.07 $212.00 8.Project Equipment Costs(40%of total equipment costs) $165.73 $0.00 9.Material Handling(8.30%of lines I &2) $47.93 $47.93 10.Inspection(6.84%of line 4) $0.00 $51.88 11.Total Cost of Project $1,357,72 $1,763.48 12.Work Order Estimate(Line 11 minus line 8,9.&10) $1,144.06 $1,715.55 13.Billable Equipment Depreciation(60%of total equipment costs) $248.59 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11+13+(58.71%of 4&7)) $1,821.53 $1,887.95 15.Billing Estimate(W/O Transformer Cost)(Lines 11+13+(58.71%of 4&7)-Line 2) $1,821.53 $1,887.95 Time Estimate Crew Hours Total Manhours 2.30 9.19 --------------------------------------------------------------------------------------------------------------- LPA 1MMP16.F a� CUE Reports Estimate Number:33093 348 OCEAN BV./35'W POLE Estimate Type:SIR Contractor.HENKELS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#/Task:30259596 Required Date: Oracle Project M 8004473 Estimated On: 03/20/2018 CU Detail StatLon,,,,,,, 348 OCEAN BV. Build Transfer Remain In Place Remove C.2/OP 65 G3W I G3W*2 1 GY3 1 GY3*5 1 P.35/4W 1 S4 1 S4*1/0 1 Station: 2 359 OCEAN BV. Build Transfer Remain In Place Remove RUBUP 2 S20ES 1 S20ES*2/0-2/0 1 S4 1 S4*2/0 1 RUBDOWN 2 L117.4 '"011111-r a� CUE Reports Estimate Number:33093 348 OCEAN BV.1 35'W POLE Estimate Type:SR Contractor:HENKELS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#/Task:30259596 Required Date: Oracle Project#:8004473 Estimated On: 03/20/2018 Conductor, Conduit and Pipe Detail Quantities From Station To Station CU Build Transfer Remain Remove 01 2 C.2/OP 65 0 0 0 ICA '"NIPPM-ff a CUE Reports Estimate Number:33093 348 OCEAN BV.1 35W POLE Estimate Type:SIR Contractor.HENKELS&MCCOY INC INSTALL Estimate Version: By: SIMPRI3 MWO#/Task:30259596 Required Date: Oracle Project#:8004473 Estimated On: 03/20/2018 Material Summary Item Quantity Item Number Item Description 2 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZED 10"X 8'X 1-1/4", SHIP ON OPEN FLATBED ONLY! 2 BOLMS036 BOLT, MACHINE,3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 65 CAJOS002 CABLE, 2/0 (PAP), OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX CABLE"MESA VERDE" PRE-ASSEMBLED PARALLEL SOUTHWIRE61- 28-96-1, 1500 FOOT REELS 2 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 1 CLASR002 CLAMP, STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP I CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE:#6-2/0 2 CLASS004 CLAMP, STRAIGHT STRAIN,ALUMINUM, 5000#,4-3/0 ALUM 6 CNNCP002 CONNECTOR,#2,6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 5 CNNCP004 CONNECTOR,#4, 1/0-00 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 4 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, VISE GRIP PARALLEL, BRONZE 22 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON PLASTIC REEL,4"X 11.5"W/2"HOLE 140 COBCW014 CONDUCTOR, #4,TYPE 40 DSA, COPPERWELD&COPPERWELD- COPPER.204" DIAMETER 1480#BREAKING STRENGTH ( 50#COIL- 427' ) 4 COVIC002 COVER, "D"DIE, INSULATING,2-1/2' 2 GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 2 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL 3/8"AND 7/16"GUY STRANDS (DISTRIBUTION) 2 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE,20,000 LB MIN. ULT. STRENGTH. FOR WOOD OR CONCRETE POLES 4 GUYGRO01 GRIP, GUY, 3/8", 26", GALVANIZED 100 GUYST005 STRAND, GUY,3/8"DIA,7 PER STRAND, GALVANIZED STEEL, CLASS "B" GALV. OR BEZINOL IS ACCEPTABLE (500'COIL) 1 INSGBOO2 INSULATOR, STRAIN, GUY BREAKER,21,000#RATED, 60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 4 INSSU002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 1 POLWO003 POLE,WOOD, 35'CLASS 4 (TIL=44), WEIGHT=1,026 LBS 2 RODGRO03 ROD, GROUND, THREADLESS, 5/8"X 8', SHIP ON OPEN FLATBED ONLY1 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5"HIGH X 2" WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 2 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X 2"DIAMETER, GALVANIZED, 500 EACH PER BOX IX.'-.4 -MPPMMr a- CUE Reports Estimate Number.33093 348 OCEAN BV./35'W POLE Estimate Type:SR ContractorHENKELS&MCCOY INC INSTALL Estimate Version: By; SIMPRB MWO#17ask:30259596 Required Date: Oracle Project M 8004473 Estimated On: 03/20/2018 2 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4", 5/8"X 3/4"BOLT SIZE, GALVANIZED 2 WASSP002 WASHER, SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED(EXTRA HEAVY DUTY) CUE Reports Estimate Number:33093 348 OCEAN BV./35'W POLE Estimate Type:SIR Contractor.HENKE LS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#/Task:30259596 Required Date: Oracle Project#:8004473 Estimated On: 03/20/2018 CU Summary BUILD CU Name Quantity Description C,2/0P 65 2/0 AAC PAP W1 2/0 AAAC NEUTRAL G3W*2 I WOOD POLE-NON-EQUIPMENT GROUND GY3*5 1 GY3*5 3/8"DOWNGUY W/8 FT SCREW ANCHOR P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBLIP 2 LINE RUBBER INSTALLATION, PER SECT. S20ES 1 SECONDARY CONNECTION AT POLE S20ES*2/0-2/0 1 SECONDARY CONNECTION AT POLE S4*110 1 SECONDARY DEADEND S4*2/0 I SECONDARY DEADEND EMOVE Ouantity Descruptlon RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT.