Loading...
967 CAMELIA ST-TRUSS REPAIR & RE-ROOF o\ Permit Reviews City of Atlantic Beach .. Permit Number: RES18-0014 Description: replace damaged trusses&complete re-roof Applied: 1/16/2018 Approved: 1/22/2018 Site Address: 967 CAMELIA ST Issued: 1/25/2018 Finaled:3/22/2018 City,State Zip Code: ATLANTIC BEACH, FL 32233 Status: FINALED Applicant: <NONE> Parent Permit: Owner: PASSAFARO ANGELA M Parent Project: Contractor: <NONE> Details: LIST OF REVIEWS SENT DATE RETURNED DUE DATE TYPE CONTACT STATUS REMARKS DATE Review Group:AUTO 1/16/2018 1/16/2018 SUBMITTAL Jennifer Johnston APPROVED COMPLETENESS W/CONDITIONS Notes: 1/16/2018 1/22/2018 1/26/2018 BUILDING Building APPROVED Notes: Printed:Tuesday,08 January, 2019 1 of 1 • DESIGN .CRITERIA AND LOADS LEGEND AND FRAMING NOTES. Building Code INTERIOR ROOF LOAD BEARING WALL 5th Edition (2014) Florida Building, Residential, Existing Codes Code for Design Loads STRUCTURAL WOOD BEAM ASCE / SEI 7-10 t Construction Type �, O R A C L REPAIR INTERIOR FLOOR LOAD BEARING WALL. NO ATC REQUIRED. Y2 x 6 Repair Area (°10 of Gross) EMBED ANCHORS WITH WASHERS @ 48" O.C. NC! N E 6 i I "� (UNO) UNLESS NOTED OTHERWISE ON PLAN OR DETAIL i 15% EOR ENGINEER OF RECORD ORACLE Engineering g & ROOF LOADING (Cd= 1.25) Hu Construction Services, TOP CHORD LIVE LOAD " 20 psf HEADER FRAMING I N G Inc. TOP CHORD DEAD LOAD 10 psf i BOTTOM CHORD LIVE LOAD " 10 psf 2 2 x 6 - 1 / 2 HEADER/BEAM CALL -OUT O 2714 Saint Johns Ave BOTTOM CHORD DEAD LOAD 5 psf NUMBER OF KING STUDS EACH SIDE OF OPENING Jacksonville, FL 32205 BOTTOM CHORD LIVE LOAD (STORAGE)" 20 psf NUMBER OF JACK STUDS EACH SIDE OF OPENING (904) 518-5000 " CONCURRENTLY LOADED LIVE LOADS MAY BE REDUCED SIZE OF HEADER MATERIAL (NO.2 SYP) PER FBC 1605.3.1.1 NUMBER OF PLIES IN HEADER I FL Cert. Of Au th. No.: ** WHERE 2 OR MORE ADJACENT TRUSSES ARE CAPABLE OF ACCOMODATING 24"x42" BOX WITHIN PLANE OF TRUSS. • ALL HEADER JACK AND KING STUS SHALL BE FASTENED TO EACH OTHER WITH (2) ROWS 10d I 30597 COMMON @ 8' O.C. STAGGERED. l i TRUSS DEFLECTION CRITERIA • TOP PLATE TO HEADER CONNECTION (ONE OF THE FOLLOWING): ROOF TRUSS/RAFTER - NO CONNECTION FOR HEADERS LES THAN 36" LU240 SPH W/ (12)1Od x 1-Y2" @ 32" O.C. OR TU180 -DSP W/ (14) 1 O COMMON @ 16" (5-C7 OR -FASTEN TRUSS DIRECTLY TO HEADER W/ MTS OR HTS W/ (14) 10d x 1-i2" (OR EQUAL APPROVED BY EOR) I = • WINDOW OPENINGS 4' AND GREATER REQUIRE Y" ANCHOR BOLTS OR REDHEADS W/ 14/" DIA F WIND LOADING (Cd 1.fi0) " 2 2 i WASHERS AT 48 (MAX) ON CENTER UNDER WINDOW CONNECTION BOTTOM PLATE TO SLAB. ASCE 7-10, 3 SEC. GUST ULTIMATE DESIGN WIND SPEED, Vult 130 mph • IF HEADER NOT SPECIFIED, CONTACT ENG NOMINAL DESIGN WIND SPEED,' 101 mph ENGINEER OF RECORD EXPOSURE CATEGORY asd C Openings 111 i 6' S . OPENINGS IN 2x4 STUD WALLS RISK CATEGORY 11 P 9 LS GREATER THAN 6' REQUIRE A (2) 2x4 NO.2 SPF PLANK ORIENTED PLATE ENCLOSURE CLASSIFICATION ENCLOSED (2X4 Wells) DIRECTLY ABOVE AND BELOW THE OPENING W/(6)12d COMMON TOE -NAILS AT EACH END INTERNAL PRESSURE COEFF 0.18 C&C DESIGN PRESSURES SEE TABLES 1, 2 & 3«*. Openings > $ 8' • OPENINGS IN 2x6 STUD WALLS GREATER THAN REQUIRE A (2) 2x6 N0.2 SPF PLANK ORIENTED PLATE FT I MEAN ROOF HEIGHT 30 . (MAX) DIRECTLY ABOVEAND BELOW THE OPENING W/(8)12d COMMON TOE -NAILS AT EACH END ROOF ANGLE O 26.6° (6:12)2) (2X6 We��S) i **" VALUES SHOWN IN TABLES 1, 2 AND 3 BELOW INCLUDE THE I 0.6 LOAD REDUCTION FACTOR FOR ALLOWABLE STRESS DESIGN ASD IN ACCORDANCE WITH THE 5th EDITION 2014 FBC R301.2.1.6. NO FURTHER REDUCTIONS ARE PERMITTED. TABLE 2: NAIL SIZE LEGEND FEMA FLOOD INFORMATION PER FBC 1603.1.7 FIRM MAP ITEM ID 12031 CO408H EFFECTIVE DATE JUNE 3, 2013 FLOOD ZONE X - SHADED TABLE 1 COMPONENT AND CLADDING DESIGN PRESSURES r- J(–RO—O_F- Q LJ , m ITABLE 3: FASTENERS IN TREATED LUMBER 0" U Zone signation DIAMETER LENGTH 8d COMMON 0.131" 2-Y" 8dRINGSHANK 0.120" 2-Y2' I Od x 1-Y2" 0.148" 1-Y2" 10d COMMON 0.148" 3" 12d COMMON 0.148" 3-Y4" 16d SINKER 0.148" .-3-y4'. 16d COMMON 0.162" 3-Y2', r- J(–RO—O_F- Q LJ , m ITABLE 3: FASTENERS IN TREATED LUMBER 0" U Zone signation Interior Zone ACQ & NON CONNECTORS MUST HAVE Z -MAX, G120 OR TRIPLE ZINC COATED FINISH. Interior Zone LEffective End Zone Comer Zone STANDARD FINISH IS ACCEPTABLE (UNO) (psf) (pso (psfi REQUIRED. AFF ABOVE 'FINISHED FLOOR H. HB HOSE BIB HS HORIZONTAL SLIDER Wind Area 11 - 20 sq, ft. 0 -10 sq. ft. +18 -28 +18 -49 +18 -72 L 11 - 20 sq. ft. +16 -27 -33 +16 -45 +16 -67 21 50 ft +14 -26 +14 -40 +14 -61 CABS CABINETS PRESERVATIVE Interior Zone ACQ & NON CONNECTORS MUST HAVE Z -MAX, G120 OR TRIPLE ZINC COATED FINISH. -DOT BORATE ALL FASTENERS MUST BE HOT DIPPED GALVANIZED. SODIUM BORATE STANDARD FINISH IS ACCEPTABLE (UNO) ACZA NOT RECOMMENDED. STAINLESS CONNECTORS AND FASTENERS NAILS REQUIRED. (J') Q z Q Q <tw_ _J m F- U) LLI Q U� U �C 1-= ABBREVIATIONSQ Uz I I o In Q - sq. Interior Zone ABV ABOVE End Zone l'- 51 -100 sq. ft. +12 -25 +12 -36 +12 -57a a Y AC AIR CONDITIONER (psf) d� Q U NAILS ROOF OVERHANG AFF ABOVE 'FINISHED FLOOR H. HB HOSE BIB HS HORIZONTAL SLIDER Wind Area 11 - 20 sq, ft. Structural Summar AHU AIR HANDLER UNIT 21 - 50 sq. ft. L ^�- /� _ TABLE 2 COMPONENT AND • INSTALL COMMON NAILS UNLE$S:OTHERWISESPECIFIED -33 BF BIFOLD DOORS BILK BLOCK -41 � • COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS BEFORE APPLICATION OF -32 CABS CABINETS -38 U.l J.CLADDING - �PRESSURES -30 CL CEILING LINE -35 51 -100 sq. ft. PROTECTIVE COATING. ,-''' WALL • WHEN A BORED HOLE ISREQUIRED TO PREVENT SPLITTING OF A WOOD DUE TO FASTENER _ CLG CEILING -32 (n .r Z �' ._.: � ..�_ ° PENETRATION THE BORED HOLE SHALL NOT EXCEED 75 /o OF THE NAIL OR SPIKE DIAMETER -26 CHR CHAIR RAIL -26 �, 0 � 0 Zone Interior Zone FR FRENCH DOOR End Zone Designation (psf) a Y FXD FIXED FXT FIXTURE g. GALLON - GLS GLASS (psf) Effective SHEET NO.: S —_ ROOF OVERHANG 0 -10 sq. ft. H. HB HOSE BIB HS HORIZONTAL SLIDER Wind Area 11 - 20 sq, ft. Structural Summar -86 21 - 50 sq. ft. 0 -10 sq. ft. +31 -33 +31 -41 11 - 20 sq. ft. +29 -32 +29 -38 21 - 50 sq. ft. +28 -30 +28 -35 51 -100 sq. ft. +26 -29 +26 -32 101 - 500 sq. ft. +23 -26 +23 -26 • THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS SPECIFIED FOR THIS PROJECT ARE AS COFF COFFERED O'< 0 = LISTED IN TABLE 2 BELOWGOL COLUMN _ Z E.. C)M -® w COMP COMPRESSORV 0 v CRN CROWN MOULDING w CVAC CENTRAL VACUUM SYSTEM C] Z o ZZ DBL DOUBLE d e£ u_ DIAG DIAGONAL U � 0 1 DR DOOR M <t t: a DRY DRYER SPACE P ACE O U. tL CC w ���* DW DISHWASHER Q >. a CCM EB EYEBROW 1t1 t to Mp FL FLOOR LINE (MAT ' CHANGE) i.} N C3 FLR FLOOR RCcc us FP FIREPLACE 1, E Zone } FR FRENCH DOOR Designation Imo• QC TABLE 3 COMPONENT AND CLADDING DESIGN PRESSURES a Y FXD FIXED FXT FIXTURE g. GALLON - GLS GLASS (psfl Wind Area SHEET NO.: S —_ ROOF OVERHANG 0 -10 sq. ft. H. HB HOSE BIB HS HORIZONTAL SLIDER -96 11 - 20 sq, ft. Structural Summar Zone KS KNEE SPACE Designation End Zone Corner Zone Effective (psf) (psfl Wind Area u R&S CLOTHES ROD and SHELF 0 -10 sq. ft. -57 -96 11 - 20 sq, ft. -57 -86 21 - 50 sq. ft. -57 -74 51-100 sq. ft. -57 -65 KS KNEE SPACE Y LAV LAVATORY JOB NO.: u R&S CLOTHES ROD and SHELF LT LAUNDRY TUB MRBL MARBLE 1740 MC MEDICINE CABINET MIR MIRROR REF REFRIGERATOR SPACE RV RECREATIONAL VEHICLE SUBDIVISION: DESIGNED: MTL METAL OH OVERHANG SD SOAP DISH SDLTS SIDE LIGHTS OHC OVERHEAD CABS AFL REVIEWED: AFL r- OHD OVERHEAD DOOR (GARAGE) OPNG OPENING LOT NO.: k. SGD, SLIDING GLASS DOOR SH SINGLE HUNG OPT , OPTIONAL ORV OPEN ROOF VENT ADDRESS. PKT POCKET DOOR - u R&S CLOTHES ROD and SHELF REF REFRIGERATOR SPACE RV RECREATIONAL VEHICLE DESIGNED: SD SOAP DISH SDLTS SIDE LIGHTS AFL REVIEWED: AFL r- k. SGD, SLIDING GLASS DOOR SH SINGLE HUNG _ SHV SHELVES REVISIONS DATE WORK AREA EX. BUILDING (2nd LEVEL) a (tya.) 7- END ZONE DESIGNATION a = 3.3 FT - SMD SMOKE DETECTOR SOAP- SOAP DISH TB TOWEL BAR TH TOP HINGED TPH TOILET PAPER. HOLDER T&S TUB and SHOWER TEMP TEMPERED TOB TOP OF BLOCK (CMU) TR TRANSOMS UNO UNLESS NOTED OTHERWISE VLT VAULT VOL VOLUME WC WATER CLOSET WD WOOD l,$alsga am s a No. ?Q m a9 S�q(yg ®y ♦ • L 1 A p .. L.E ada SAPH35dg�lD9®'i® Mail0!!9 WH WATER HEATER I- L L J WNCT WAINSCOT WS WATER SOFTENER WSH WASHER SPACE ANDRES F. LOPERA PE # 70791 12/11/2017 NEW TRUSSES SHALL BE DESIGNED AND NEW E OUTLOOKERS SHALL BE INST LLED 9. ALL DIMENSIONS SHOWN 'SHALL BE FIELD VERIFIED BY THE DETAILED PER SHEET S-5 ANDFOR NEW GABLE TRUSS, PER "GALE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. TRUEHOUSE SHOP DRAWINGS DATED DETAIL,"SHEET S-6. 10; IF ADDITIONAL SPLITS, CRACKS OR FRACTURES ARE FOUND 3/02/2016. ON EXISTING TRUSSES OUTSIDE OF THE SHOWN SCOPE OF WORK, CONTRACTOR SHALL CONTACT E.O.R. FOR SITE VISIT, NOTE FOR TRUSS T04: SCAB NEW 2x4x48" LONG No.2 SYP TO EX. TRUSS ►'� SCAB w/(2) ROWS 10d N U COMMON AT 6" O.C. N Q LiJ CUT AND REMOVE 16,, 4'-0" Q Ld m LONG OVERHANGS FROM III TRUSSES, AS SHOWN � � " U EX. GABLE T GE03 EX. GABLE E03 T SCAB NEW 2x4x48" Q I-- = 1=- LONG No.2 SYP TO C U Z \ i EX. TRUSS TOP �-- < Q EX. TSS (T05) T (T05) CHORD w/(2) ROWS Q T �� EX. SS — 10d COMMON AT 6» ( f..) W m 0. C. _ U EX. T SS (T06) _ L EX. T SS (T06 0 I— �- 9 CLG. '�� \ I I '_" I Q �C U Z 0 Q d MA. BA. I (_0 F- 0-) <C U 9' CLG. N I ( EX. 030 L G LK \ CUT AND ' REMOVE EX ` \ I TRUSS GE01 AND EX. 7-00 O 0 . TRUSS T03 L0_ 0 NEW TRUSSES P y SES ER NOTE ABOVE OTEABOVE AND SHEET S-5. i\ I \ \ F o �I BED 2 I, I I W 1 0 CLG. L LL.. N EX. 3050 ¢ I SH o I I- r � N►, IN _jI \ I (' � -11-11 Cr I� Cn OFFICE GOP X X X IX IW W t W I W SWI W Z Z'f y O) IN w i BA. 2 I i 9 CLG. EX. I SHEET NO.: 2020 SH \ S-2 i I ( ( Floor Plan I Truss Plan \ 1 JOB NO.: 17_40 `I SUBDIVISION: N BED 3 I i�'� •� 9' CLG. I I LOT NO.: ADDRESS: L.L r DESIGNED: AFL EX. (2) 3050 SH REVIEWED: AFL REVISIONS DATE ell - PARTIAL 2nd PARTIAL PARTIAL i . '0 n w 99 � 9 99 99 9 99z. ����'� 99 V_0" O R PLAN EX. 1 4 1 � TRUSS PLAN EX. 1 4 �- 1 � TRUSS PAil -E� 0 / � VIEW 1 4 OF t o� t z u c... ,am ..; „rt;tLki:U4; 441#itFt� I ANDRES F. LOPERA PE # 70791 12/11/2017 i LEGEND: GENERAL PLAN NOTES: 1. FOR GENERAL NOTES AND KEYNOTE SPECIFICATIONS, SEE r7 -7 N SHEETS -1. DEMO COMPONENT NO2. IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD. 3. SIMPSON ACRYLIC—TIE ADHESIVE SHALL BE USED IN ALL DRILLED AND EPDXIED CONNECTIONS TO CONCRETE. O A C L ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN A ENG 6 N E E R I HOLE k6" GREATER THAN THE DIAMETER OF THE ANCHOR. MANUFACTURER'S SPECIFICATIONS MUST BE FOLLOWED FOR ORACLE Engineering & PROPER INSTALLATION. Construction Services, Inc. 4. FASTEN ALL MULTI -PLY STUD COLUMNS UNDER BEAMS/GIRDERS W./ (2) ROWS 10d COMMON ® 8" A.C. 2714 Saint Johns Ave STAGGERED. Jacksonville, FL 32205 5. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR (904) 518-5000 DRY USE ONLY, LINO. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BEDESIGNED AND DETAILED FL Cert. of Auth. No.: BY OTHER. _ I 30597 6. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN FLORIDA BUILDING CODE TABLE 2304.9.1 FASTENING SCHEDULE. 7. ALL WATERPROOFING AND FLASHING DETAILS TO BE DESIGNED AND DETAILED BY OTHERS. I • 8. ALL MECHANICAL, ELECTRICAL AND PLUMBING REPAIRS TO NOTE FOR TRUSS GE01 AND T03. NOTE FOR OUTLOOKERS• BE DESIGNED AND DETAILED BY OTHERS NEW TRUSSES SHALL BE DESIGNED AND NEW E OUTLOOKERS SHALL BE INST LLED 9. ALL DIMENSIONS SHOWN 'SHALL BE FIELD VERIFIED BY THE DETAILED PER SHEET S-5 ANDFOR NEW GABLE TRUSS, PER "GALE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. TRUEHOUSE SHOP DRAWINGS DATED DETAIL,"SHEET S-6. 10; IF ADDITIONAL SPLITS, CRACKS OR FRACTURES ARE FOUND 3/02/2016. ON EXISTING TRUSSES OUTSIDE OF THE SHOWN SCOPE OF WORK, CONTRACTOR SHALL CONTACT E.O.R. FOR SITE VISIT, NOTE FOR TRUSS T04: SCAB NEW 2x4x48" LONG No.2 SYP TO EX. TRUSS ►'� SCAB w/(2) ROWS 10d N U COMMON AT 6" O.C. N Q LiJ CUT AND REMOVE 16,, 4'-0" Q Ld m LONG OVERHANGS FROM III TRUSSES, AS SHOWN � � " U EX. GABLE T GE03 EX. GABLE E03 T SCAB NEW 2x4x48" Q I-- = 1=- LONG No.2 SYP TO C U Z \ i EX. TRUSS TOP �-- < Q EX. TSS (T05) T (T05) CHORD w/(2) ROWS Q T �� EX. SS — 10d COMMON AT 6» ( f..) W m 0. C. _ U EX. T SS (T06) _ L EX. T SS (T06 0 I— �- 9 CLG. '�� \ I I '_" I Q �C U Z 0 Q d MA. BA. I (_0 F- 0-) <C U 9' CLG. N I ( EX. 030 L G LK \ CUT AND ' REMOVE EX ` \ I TRUSS GE01 AND EX. 7-00 O 0 . TRUSS T03 L0_ 0 NEW TRUSSES P y SES ER NOTE ABOVE OTEABOVE AND SHEET S-5. i\ I \ \ F o �I BED 2 I, I I W 1 0 CLG. L LL.. N EX. 3050 ¢ I SH o I I- r � N►, IN _jI \ I (' � -11-11 Cr I� Cn OFFICE GOP X X X IX IW W t W I W SWI W Z Z'f y O) IN w i BA. 2 I i 9 CLG. EX. I SHEET NO.: 2020 SH \ S-2 i I ( ( Floor Plan I Truss Plan \ 1 JOB NO.: 17_40 `I SUBDIVISION: N BED 3 I i�'� •� 9' CLG. I I LOT NO.: ADDRESS: L.L r DESIGNED: AFL EX. (2) 3050 SH REVIEWED: AFL REVISIONS DATE ell - PARTIAL 2nd PARTIAL PARTIAL i . '0 n w 99 � 9 99 99 9 99z. ����'� 99 V_0" O R PLAN EX. 1 4 1 � TRUSS PLAN EX. 1 4 �- 1 � TRUSS PAil -E� 0 / � VIEW 1 4 OF t o� t z u c... ,am ..; „rt;tLki:U4; 441#itFt� I ANDRES F. LOPERA PE # 70791 12/11/2017 9. ALL DIMENSIONS SHOWN SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 10. IF ADDITIONAL SPLITS, CRACKS OR FRACTURES ARE FOUND ON EXISTING TRUSSES OUTSIDE OF THE SHOWN SCOPE OF WORK, CONTRACTOR SHALL CONTACT E.O.R. FOR SITE VISIT. II i, O.C. SPACING LUMBER SIZE 2x6 I 2X8 LEGLND: GENERAL PLAN NOTES: 14'-5" 18'-3" 16" 12'-6" 15'-10" 24" 1. FOR GENERAL NOTES AND KEYNOTE SPECIFICATIONS, "SEE 20 LL/15 DL No.2 SYP 3'-0" OVER F SHEET S-1. HANG a HANG Q I� \N DEMO COMPONENT 2. IF HEADER NOT. SPECIFIED, CONTACT ENGINEER RECORD. 1, 0„ z 'w \ OF =0w OVERHANG 3. SIMPSON ACRYLIC—TIE- ADHESIVE SHALL BE USED IN ALL DRILLED AND EPDXIED CONNECTIONS TO CONCRETE. �.A (2 L E ANCHOR BOLT,. THREADED ROD, OR DOWELED REINFORCING i 7. COI STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN A N G I N E E R IN G HOLE X6" GREATER THAN THE DIAMETER OF THE ANCHOR. MANUFACTURER'S SPECIFICATIONS MUST BE FOLLOWED FOR ORACLE Engineering & 011 is 011 PROPER INSTALLATION. Construction Services, z \ ` I OVER d \ I HANG Inc. W 0 Ld m 4. FASTEN ALL MULTI -PLY STUD COLUMNS UNDER \ > d cr I > LL n/ BEAMS/GIRDERS W./ (2) ROWS 10d COMMON 0 8" O.C. 2714 Saint Johns Ave \ I CF_ STAGGERED. Jacksonville, FL 32205 5.ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR 904 518-5000 5 00 U/ C) DRY USE ONLY, LINO. ALL WATERPROOFING AND FIRE w I \ I w SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE \ I CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED FL Cert. of Auth. No.: V) I BY OTHER: 30597 < 6. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN � \ I ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN FLORIDA BUILDING CODE TABLE 2304.9.1 FASTENING Q F _ U z 0 SCHEDULE. \ ec- 7. ALL WATERPROOFING AND FLASHING H1NG DETAI LS TO BE II DESIGNED AND DETAILED Y D D LED B OTHERS. 8. ALL MECHANICAL, ELECTRICAL AND PLUMBING REPAIRS TO L O-)<C) BE DESIGNED AND DETAILED BY OTHERS. NOTE: 9. ALL DIMENSIONS SHOWN SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 10. IF ADDITIONAL SPLITS, CRACKS OR FRACTURES ARE FOUND ON EXISTING TRUSSES OUTSIDE OF THE SHOWN SCOPE OF WORK, CONTRACTOR SHALL CONTACT E.O.R. FOR SITE VISIT. II i, O.C. SPACING LUMBER SIZE 2x6 I 2X8 12"' ` 14'-5" 18'-3" 16" 12'-6" 15'-10" 24" OVER 20 LL/15 DL No.2 SYP 3'-0" OVER HANG a HANG Q 1, 0„ z 'w =0w OVERHANG o i 7. COI r CO 011 is 011 z \ ` I OVER d \ I HANG OVER HANG z W 0 Ld m \ > d cr I > LL n/ \ I CF_ \ \ \ U/ C) w I \ I w Q Q W Q \ I V) I < � \ I (i� � U UC I Q F _ U z 0 \ ec- Q_ d L O-)<C) \ 1 \ CUT AND REMOVE EX. I NEW ROOF SHEATHING, _ \ ROOFI SHEATH NG, AS P T A T PER YP WALL SECTIONS, SHOWN SHEET S-6 �I EX. RIDGE ( �\ \ ` I EX. RIDGE 4 I I� \ I \ i \ I I\ \ I E I� EX. GABLE I EX GABLE OVER—FRAMED RAFTER SPAN SCHEDULE O.C. SPACING LUMBER SIZE 2x6 I 2X8 12"' ` 14'-5" 18'-3" 16" 12'-6" 15'-10" 24" 10'-2" 12'-11" 20 LL/15 DL No.2 SYP S� j I Sheathing Plan JOB NO.: 17_40 SUBDIVISION: 5, 0„ LOT NO.: EX. GABLE z EX. GABLE Z ADDRESS: DESIGNED: AFL REVIEWED: AFL REVISIONS DATE M l�f P PARTIAL R00� PARTIAL MUUr h� � f0✓91 97 99 9 99 Y �I b X� 1 4 -- 1'_0" SHEATHING PI�A�I — NEW 1 4 -- t S H E A THING PIAN E 1 0 � � m a �m v �. _ _ - {d�'dFt$d61"66146iAA1gl11n, ANDRES F. LOPERA PE _ # 70791 12/11/2017 _ LLJ_ �tryd w0-1 I tX,tir _bi '- 1, 0„ 1, 0„ OVERHANG OVERHANG i ADDRESS: DESIGNED: AFL REVIEWED: AFL REVISIONS DATE M l�f P PARTIAL R00� PARTIAL MUUr h� � f0✓91 97 99 9 99 Y �I b X� 1 4 -- 1'_0" SHEATHING PI�A�I — NEW 1 4 -- t S H E A THING PIAN E 1 0 � � m a �m v �. _ _ - {d�'dFt$d61"66146iAA1gl11n, ANDRES F. LOPERA PE _ # 70791 12/11/2017 i LEGEND: GENERAL PLAN NOTE.S. � 1• FOR GENERAL NOTES AND KEYNOTE SPECIFICATIONS, SEE (« SHEET S-1. \\ \ DEMO COMPONENT \\ '� ENT 2. IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD. 3. SIMPSON ACRYLIC -TIE ADHESIVE SHALL BE USED IN ALL DRILLED AND EPDXIED CONNECTIONS TO CONCRETE. ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING RACLE STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN A N G I N F E A : N HOLE Y,&" GREATER THAN THE DIAMETER OF THE ANCHOR. MANUFACTURER'S SPECIFICATIONS MUST BE FOLLOWED FOR ORACLE Engineering PROPER INSTALLATION. Construction Services, Inc. 4. FASTEN ALL MULTI -PLY STUD COLUMNS UNDER BEAMS/GIRDERS W./ (2) ROWS 10d COMMON ® 8„ O.C. STAGGERED. 2714 Saint Johns Ave Jacksonville, FL 32205 5. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR904 DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE ( ) 518-5000 000 SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED FL Cert. of Auth. No.: CUT AND REMOVE SECTION BY OTHER. 30597 48•. OF EX. TRUSS TOP CHORD, 1 Z AS SHOWN 6. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN 6 FLORIDA BUILDING CODE TABLE 2304.9.1 FASTENING SCHEDULE. 7. ALL WATERPROOFING AND FLASHING DETAILS TO BE DESIGNED AND DETAILED BY OTHERS. III i 8. ALL MECHANICAL, ELECTRICAL AND PLUMBING REPAIRS TO BE DESIGNED AND DETAILED BY OTHERS. I 9. ALL DIMENSIONS SHOWN SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO THE STAT FCONSTRUCTION. i E R 0 10 IF ADDITIONAL SPLITS, TS CRACKS OR FRACTURES ARE FOUND UN D ON EXISTING TRUSSES OUTSIDE OF THE SHOWN SCOPE OF FRONT RIGHT WORK, CONTRACTOR SHALL CONTACT E.O.R. FOR SITE VISIT. (WES T WEST EX. DOUBLE EX. HANGER CONNECTION EX. (2) PLY GIRDER TRUSS TOP_ PLATE TO EX. TRUSS 99 V_0" N =N EX. TRUSS T04 DEMO 1 4 I—�W 0 W Ill II, I-- _ � Q C)z LL Q Q Q <c Ld -� U� w °° Q dC c� z o n < (_0 0-) < C) L INSTALL NEW 2x4x4'-0 No.2 SYP SCAB TO BOTH FACES OF NEW SCRIBE AND TO EX. P CHORD w TO C 0 D /(2) I ` ROWS OF SDS 1/4"0 x 6 „ LONG SCREWS AT 6 O.C. PRE DRfLLED ( ) FI COPY SCRIBE IN NEW No.2 SYP 12 2x4x4 -O LONG SHEET NO.: 6_4 S i NEW 3/4" PLYWOOD J GUSSET TO BOTH FACES OF TRUSS w/(1) ROW OF TC"USS Details 1 O x 1 1/2 AT 6,, O.C., 1- I o STAGGERED TO EACH JOB NO.: MEMBER. 17_40 K SUBDIVISION: FRONT:... 40-0" RIGHT LOT NO.: WEST(WEST)ADDRESS: EX. DOUBLE EX. HANGER CONNECTION EX. (2) PLY GIRDER TRUSS DESIGNED: TOP PLATE TO EX. TRUSS , AFL REVIEWED: AFL REVISIONS DATE it 99 V_0" EX. TRUSS Tao — REPAIR 1 4 III <ti F®, ve mm.ym,a.ja o o. 70791 w n n m STATE MJF �AL� t<S� .. FjLI/1389d�68F449!!ltl515691t ANDRES F. LOPERA PE # 70791 12/11/2017 2/ /2017 I GEN RA P r. LEGEND. E L LAN NOTES. 1. FOR GENERAL NOTES AND KEYNOTE SPECIFICATIONS, SEE (« SHEET S-1. DEMO COMPONENT 2. IF HEADER NOT SPECIFIED, CONTACT ENGINEER OF RECORD. 3. SIMPSON ACRYLIC—TIE ADHESIVE SHALL BE USED IN ALL DRILLED AND EPDXIED CONNECTIONS TO CONCRETE. ANCHOR BOLT, THREADED ROD, OR DOWELED REINFORCING N [ N R N STEEL MAY BE EMBEDDED TO THE SPECIFIED DEPTH, IN A NOTE FOR TRUSS GE01 AND T03: HOLE Ys GREATER THAN THE DIAMETER OF THE ANCHOR. MANUFACTURER'S SPECIFICATIONS MUST BE FOLLOWED FOR ORACLE Engineering Sc PROPER INSTALLATION. Construction Services, Inca 4. FASTEN ALL MULTI—PLY STUD COLUMNS UNDER BEAMS/GIRDERS W./ (2) ROWS 10d COMMON @ 8" O.C. 2714 Saint Johns Ave STAGGERED. Jacksonville, FL 32205 5. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR (904) 518-5000 DRY USE ONLY, UNO. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE FL Cert. of AUth. No.: CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. 30597 i 6. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN OFFICE COPY FLORIDA BUILDING CODE TABLE 2304.9.1 FASTENING SCHEDULE. 7. ALL WATERPROOFING AND FLASHING DETAILS TO BE SHEET NO.: �I ,f DESIGNED AND DETAILED BY OTHERS. II g � i 8. ALL MECHANICAL, ELECTRICAL AND PLUMBING REPAIRS TO Truss Details BE DESIGNED AND DETAILED BY OTHERS. i JOB NO.: 9. ALL DIMENSIONS SHOWN SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 1740 7 0 FRONT RIGHT SUBDIVISION: (WESIJ 10. IF ADDITIONAL SPLITS, CRACKS OR FRACTURES ARE FOUND ON EXISTING TRUSSES OUTSIDE OF THE SHOWN SCOPE OF WEST WEST) - WORK, CONTRACTOR SHALL CONTACT E.O.R. FOR SITE VISIT. 29'-9,, TRUSS GE01 99 9 9 1 Z4 = 1 -09 EX. (1) PLY GIRDER TRUSS NEW HUS26 HANGER NEW HUS26 HANGER EX: (2) PLY GIRDER TRUSS , LOT NO.: ' CONNECTION TO EX. TRUSS CONNECTION TO EX. TRUSS ADDRESS: III N 10-0 91-91,10-0 DESIGNED: Q W 291-9" 0 W1m REVIEWED: W D' U i AFL V) C) Z REVISIONS DATE LL_ TRUSS T03 99 9 1/4 1- 099 Q QW j m d� 'i' I Q U (L) Q Li w ri R S te, 4J.F 0-) Q U NOTE FOR TRUSS GE01 AND T03: � i l�"�w�� gyp• OFFICE COPY SHEET NO.: �I ,f S_5 II g � Truss Details JOB NO.: s x 1740 7 0 FRONT RIGHT a SUBDIVISION: WEST) (WE,-,) EX. (1) PLY GIRDER TRUSS NEW HUS26 HANGER NEW HUS26 HANGER EX: (2) PLY GIRDER TRUSS LOT NO.: ' CONNECTION TO EX. TRUSS CONNECTION TO EX. TRUSS ADDRESS: III 10-0 91-91,10-0 DESIGNED: AFL 291-9" REVIEWED: I AFL REVISIONS DATE TRUSS T03 99 9 1/4 1- 099 S R Faun d� 'i' A4 n S a .,A At �a 70791 w ri R S te, 4J.F � i l�"�w�� gyp• AL ANDRES F. LOPERA PE # 70791 12/11/2017 NEW MIN. 7/16 24/16 APA RATED ROOF i it SHEATHING AT REPAIR AREAS, INSTALLED W/LONG DIMENSION PERPENDICULAR TO A SUPPORTS W/ 8d RINGSHANKS: E N G I N E E R I IN G 6" O.C. AT PANEL EDGES, 12„ O.C. AT INTERMEDIATE SUPPORTS , ORACLE Engineering & 4" O.C. (EDGE AND FIELD) AT ROOF CORNERS Construction Services AND EAVES. Inca , (BLOCK ALL EDGES AT REPAIRED ROOF SHEATHING AREAS) 2714 Saint Johns Ave FIBERGLASS SHINGLE Jacksonville, FL 32205 - F OVER 1 LAYER R00 ROOFING ; 4 O�, PRE-ENGINEERED ROOF TRUSSES. 90 518 500 0 7 1 OSB No. 30 FELT OVER/ 6 I'll OVER PRE—ENG WOOD/F _ (SEE _ �, FL Cert. of Auth. No.: TRUSSES Cc? 24" OC. PLAN) I 12 30597 (SEE EX. DOUBLE TOP PLATE PLAN) UPLIFT CONNECTOR AT EACH REPAIRED TRUSS I I (SEE STRUCTURAL SECTION) IV V; EX. (2) 2x PLATE #2 SYP .,..... _ .... EACH REPAIRED OR NEW TRUSS TO TOP PLATE w/ (1) SIMPSON H2.5A OR (1) SDWC15600 (UPLIFT UP TO 600 Ib.). ALUMINUM DRIP OVER PT 1x2 / USE (1) MTS12 FOR 2 -PLY TRUSS OVER 2x6 SUB -FASCIA NEW R-38 BATT I SULATION. (MIN. R-30) EX. WALL SHEATHING FULLY VENTED VINYL SOFFIT INSTALLED PER MANUF SPEC NEW 1/2" TYPE ,, ,, or 5/8" GYPSUM BOARD @ CEILING, AS i VINYL J CHANNEL REQUIRED EX. EXTERIOR WALL STUDS EX. GYPSUM BOARD, REPAIR AS REQ. EX. UPLIFT SYSTEM EX. OSB OVER EX EX. BOTTOM PLATE 2x_ STUDS PER ENGINEERING EX. INSULATION IN WALLS N U EX. FOUNDATION Q `W 0 L,)Lm EX. VINYL LAP SIDING OR BRICK - ry ry U VENEER SIDING OVER EX. Q ►— = 1= HOUSE—WRAP FINISHED- /j�j%%jam < Lj Q NOTE GRADE\\i/\\�\\�\\�\\i Q m I-_ \\/\\/\\/\\ U Li Q —qnSEE STRUCTURAL WALL ��/\'�/\//\//\//\ U) U SECTIONS FOR\/\\�\���\ `� U Z0 CONNECTION TYPES and DETAILS. Q EX. UPLIFT SYSTEM y i- Q U I ONE-STORY TYPICAL STRUCTURAL WALL SECTION n. i EX. PT PLATE 1 - -- -- v 0 .__W, L111111ii-�Il-i 1 Illillillllliiilll���lllu� -, III, ,���III_I1I-11 a r OFFICE COPY _I FASTEN ROOF DECK TO FRAMING 3" O.C. ON EDGE, 6" O.C. IN EX. SOD@ FIELD WITH 8d RINGSHANKS 2x4 SYP OUTRIGGER" O,C. @ 24SHEET NO.: CLIP TO GABLE TOP CHORD BLOCK PANEL EDGES — WITHIN 4" OF GABLE TRUSS WITH (1) H5 S-66 — 4. EX. FOUNDATION ROOF DECK, SEE WALL SECTION BLOCK BETWEEN Details 'A 7 OUTLOOKERS. FASTEN TO GABLE TOP CHORD W/ 10d �� JOB NO.: 1-11 rTOE-NAILS @ 8 O.C. 17_40 SUBDIVISION: GABLE TOP CHORD 2x4 NO.2 SYP X -BRACING L-BRACEN AT MID SPAN AND 48" O.C. O GABLE VERTICALS MAX. RUNBACK $ FROM AS SPECIFIED BY LOT NO.: TRUSS MANUFACTURER GABLE. ATTACH TO GABLE AND TRUSS VERTICALS W/ ADDRESS: � TYP WALL SECTION 1 1 (2)12d. IF VERTICAL NOT PRESENT. SCAB FULL HEIGHT VERTICAL FROM BOTTOM CHORD TO TOP c — MONOLITHIC FOUNDATION CHORD W/ 4 10d EACH END. .J (TYP) O DESIGNED: 1 AFL GABLE TRUSS 10 REVIEWED: CLIP END OF LATERAL BRACE AFL < I TO GABLE BOT. CHORD WITH (2) H2.5 W/ (8) 8d REVISIONS DATE GABLE BOTTOM CHORD. FASTEN TO TOP PLATE groo`tII aeeIItac ss€aae,�ynF w/10d TOE NAILS AT 8" O.C. I ®,�.•.. ��®e _ , Via,= ' 2x4x8' SYP LATERAL STRAP GABLE TRUSS I ,. TO STUD WALL WITH MSTA12 BRACE @ 48' O.C. WITH 8 10d 48" O.C. a FASTENED TO EACH O @ N c�.O l 7 TRUSS W/ (2) 16d COMMON STATE OF asnm ®,..en GABLE END BRACING bETAIL�- 4 ,, 1P69@IIIE4i ANDRES F. LOPERA PE # 70791 12/11/2017 I ROOFING PER PLAN OVER ROOF FELT, PER PLAN, OVER ROOF SHEATHING PER PLAN METAL VALLEY FLASHING ICE & WATER SHIELD STRIPL FLASHING _ VALLEY FLASHING - SCALE: 3" = V-0" METAL POST VULKEM 351, 950NF, OR 951 N PRIME w/ TREMPRIME TOP COAT NON 'POROUS PRIMER VULKEM 350NF-R OR 360 NF DYMERIC 240FC OR APPROVED DETAIL COAT TREMCO SEALANT CANT BEAD NOTE: VULKEM 950NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. STS VULKEM TYP. TREATMENT OF METAL POSTS. FROM TREMCO SEALANTS DRAWING NUMBER DC -11 TYPICAL EXTERIOR FINIS FACE OF SHEATHING G.I. "Z" BAR FLASHING INSTALLED OVER FLASHING DESCRIBED BELOW CONT. PT Ix4 METAL FLASHING INSTALLED ON TO OF ROOF FELT & PRIOR TO ROOF -S INGLES OR TILE SHINGLES PER PLAN OVER ROOF FELT, PER PLAN, OVER ROOF SHEATHING PER PLAN. EDGES AND PENETRATIONS TO BE SEALED w PLASTIC CEMENT OVER ROOF FELT OVER ROOF SHEATHING PER PLAN HEAD WALL FLASHING (ROOF SLOPE MEETS ALL) SCALE: 3" = V-0 TYPICAL EXTERIOR FINISH OVER CHANNEL FLASHING UNDER BUILDING PAPER CONT. PT 1x4 ROOFING PER PLAN OVER ROOF ` FELT, PER PLAN, OVER ROOF SHEATHING PER PLAN. EDGES AND PENETRATIONS TO BE SEALED w/ PLASTIC CEMENT OVER ROOF FELT OVER ROOF SHEATHING PER PLAN THE MANUFACTURER'S .INSTALLATION INSTRUCTIONS,. BEFORE ONTO HORIZONTAL DECK EXTERIOR WALL SHEATHING 8" WIDE CONT. ROLL FLASHING NAILED TO SIDE OF 1x4 & FACE OF ROOF SHEATHING INSTALLED PRIOR TO ROOF FELT & SHINGLES SIDE WALL FLASHING (ROOF SLOPE PARALLEL TO WALL) SCALE: 3" = V-0" RING -SHANK / SCREWED INTO PLACE) METAL POST VULKEM 351, 950NF, OR 951 N PRIME w/ TREMPRIME TOP COAT NON 'POROUS PRIMER VULKEM 350NF-R OR 360 NF DYMERIC 240FC OR APPROVED DETAIL COAT TREMCO SEALANT CANT BEAD NOTE: VULKEM 950NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. STS VULKEM TYP. TREATMENT OF METAL POSTS. FROM TREMCO SEALANTS DRAWING NUMBER DC -11 TYPICAL EXTERIOR FINIS FACE OF SHEATHING G.I. "Z" BAR FLASHING INSTALLED OVER FLASHING DESCRIBED BELOW CONT. PT Ix4 METAL FLASHING INSTALLED ON TO OF ROOF FELT & PRIOR TO ROOF -S INGLES OR TILE SHINGLES PER PLAN OVER ROOF FELT, PER PLAN, OVER ROOF SHEATHING PER PLAN. EDGES AND PENETRATIONS TO BE SEALED w PLASTIC CEMENT OVER ROOF FELT OVER ROOF SHEATHING PER PLAN HEAD WALL FLASHING (ROOF SLOPE MEETS ALL) SCALE: 3" = V-0 APPROVED TREMCO SEALANT " AT ALL SILL LOCATIONS - DETAIL COAT OF VULKEM 35ONF-R MEMBRANE AT 60 MILS, ON ENTIRE ROOFS, AND SHALL OVERLAP A MINIMUM OF 3 INCHES (7 6 mm). EAVE CURB SURFACE AND RUN DOWN THE MANUFACTURER'S .INSTALLATION INSTRUCTIONS,. BEFORE ONTO HORIZONTAL DECK EXTERIOR WALL SHEATHING VULKEM 351, 950NF OR 951 NF TOP COAT JOINT FILLED w VULKEM 350NF OR 360NF BASE COAT DYMERIC 240FC ORAPPROVED TREMCO 1/4'�� HARDIE BACKER BOARD o/ SEALANT CANT BEAD 3/4 EXTERIOR GRADE PLYWOOD OPTIONAL: DUALFLEX OR CLOTH TAPE - (INSTALLED A -SIDE UP AND MUST BE WITH NO U.V. RING -SHANK / SCREWED INTO PLACE) „ (NOTE: WOOD SURFACES MUST BE PRIMED WITH y. VULKEM PRIMER ##171) SEALANT CANT BEAD- 1" WIDTH DYMERIC 240FC OR APPROVED TREMCO 1/4" BACKER - ROD SEALANT CANT BEAD- 1" WIDTH NOTE: VULKEM 950NF MAY BE USED AS TOPCOAT IN 1/4" BACKER ROD VULKEM M TYPICAL ED NOTE: VULKEM 950NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. VULKEM TYPICAL DOOR SILL DETAIL FROM TREMCO SEALANTS DRAWING NUMBER DC -28 JOINTS A MINIMUM 6" AND APPLY A COATING OR INSTALL A MINIMUM 8" WIDE ANTI -PONDING METAL FLASHING TO HOLD BACK FASCIA ENSURE POSITIVE DRAINAGE OVER FASCIA/STARTER STRIP. NAIL METAL POST VULKEM 351, 950NF, OR 951 N PRIME w/ TREMPRIME TOP COAT NON 'POROUS PRIMER VULKEM 350NF-R OR 360 NF DYMERIC 240FC OR APPROVED DETAIL COAT TREMCO SEALANT CANT BEAD NOTE: VULKEM 950NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. STS VULKEM TYP. TREATMENT OF METAL POSTS. FROM TREMCO SEALANTS DRAWING NUMBER DC -11 TYPICAL EXTERIOR FINIS FACE OF SHEATHING G.I. "Z" BAR FLASHING INSTALLED OVER FLASHING DESCRIBED BELOW CONT. PT Ix4 METAL FLASHING INSTALLED ON TO OF ROOF FELT & PRIOR TO ROOF -S INGLES OR TILE SHINGLES PER PLAN OVER ROOF FELT, PER PLAN, OVER ROOF SHEATHING PER PLAN. EDGES AND PENETRATIONS TO BE SEALED w PLASTIC CEMENT OVER ROOF FELT OVER ROOF SHEATHING PER PLAN HEAD WALL FLASHING (ROOF SLOPE MEETS ALL) SCALE: 3" = V-0 VULKEM 351, 95ONF OR 951 NF TOP COAT " VULKEM 350NF OR 360NF BASE COAT - 1/4" HARDIE BACKER BOARD o/ 3/4 EXTERIOR GRADE PLYWOOD ROOFS, AND SHALL OVERLAP A MINIMUM OF 3 INCHES (7 6 mm). EAVE ( INSTALLED A -SIDE UP AND MUST BE THE MANUFACTURER'S .INSTALLATION INSTRUCTIONS,. BEFORE NK SCREWED INTO PLACE RING -SHA / ) EXTERIOR WALL SHEATHING DETAIL STRIP OF VULKEM 350NF 1/16" THICK JOINT FILLED w OR VULKEM 360NF TREMCO APPROVED SEALANT OPTIONAL (REINFORCED w/ DUALFLEX VULKEM PRIMER #171) OR CLOTH TAPE OR FIBERGLASS TAPE) OPTIONAL: DUALFLEX OR CLOTH TAPE - NOTE: VULKEM 950NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. VULKEM TYPICAL JOINT DETAIL T VULKEM 351, 950NF OR 951 NF 0P COAT y. DYMERIC 240FC OR APPROVED TREMCO SEALANT CANT BEAD- 1" WIDTH METAL POST VULKEM 351, 950NF, OR 951 N PRIME w/ TREMPRIME TOP COAT NON 'POROUS PRIMER VULKEM 350NF-R OR 360 NF DYMERIC 240FC OR APPROVED DETAIL COAT TREMCO SEALANT CANT BEAD NOTE: VULKEM 950NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. STS VULKEM TYP. TREATMENT OF METAL POSTS. FROM TREMCO SEALANTS DRAWING NUMBER DC -11 TYPICAL EXTERIOR FINIS FACE OF SHEATHING G.I. "Z" BAR FLASHING INSTALLED OVER FLASHING DESCRIBED BELOW CONT. PT Ix4 METAL FLASHING INSTALLED ON TO OF ROOF FELT & PRIOR TO ROOF -S INGLES OR TILE SHINGLES PER PLAN OVER ROOF FELT, PER PLAN, OVER ROOF SHEATHING PER PLAN. EDGES AND PENETRATIONS TO BE SEALED w PLASTIC CEMENT OVER ROOF FELT OVER ROOF SHEATHING PER PLAN HEAD WALL FLASHING (ROOF SLOPE MEETS ALL) SCALE: 3" = V-0 IPE VULKEM 345 OR 950NF PRIME w/ TREMPRIME INTERMEDIATE COAT ON -POROUS PRIMER VULKEM 350NF-R OR 360NF DYMERIC 240FC OR APPROVED BASE COAT TREMCO SEALANT CANT BEAD VULKEM 350NF-R OR 360NF VULKEM 346 OR 951 NF TOP COAT DETAIL COAT NOTE: VULKEM 950 NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. VULKEM TYPENETRATION - FROM TREATMENT OF FROM TREMCO SEALANTS DRAWING NUMBER DC -30 2 SEE VULKEM 351 950.NF OR 951 NF TOP COA K " VULKEM 350NF OR 36ONF BASE COAT - ALUMINUM FASCIA - MECHANICALLY FASTENED FLUSH TO HARDIE BACKER BOARD ROOFS, AND SHALL OVERLAP A MINIMUM OF 3 INCHES (7 6 mm). EAVE AND PLYWOOD THE MANUFACTURER'S .INSTALLATION INSTRUCTIONS,. BEFORE 1/4" HARDIE BACKER BOARD o/ EXTERIOR WALL SHEATHING 3/4 EXTERIOR GRADE PLYWOOD EXTEND BACK ON THE ROOF FOR A MINIMUM OF 2 INCHES (51 mm). THE (INSTALLED A -SIDE UP AND MUST BE RING -SHANK / SCREWED INTO PLACE) E WITH (NOTE: WOOD SURFACES MUST BE PRIMED VULKEM PRIMER #171) VULKEM PRIMER ##171) OPTIONAL: DUALFLEX OR CLOTH TAPE - OPTIONAL: DUALFLEX OR CLOTH TAPE - EMBEDDED IN VULKEM 350NF OR EMBEDDED IN VULKEM 350NF OR 360NF DETAIL COAT 36ONF DETAIL COAT DYMERIC 240FC OR APPROVED TREMCO DYMERIC 240FC OR APPROVED TREMCO SEALANT CANT BEAD- 1" WIDTH Al 1/4" BACKER - ROD 1/4" BACKER ROD NOTE: VULKEM 950NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. VULKEM M TYPICAL ED GE DETAIL -1- FROM TREMCO SEALANTS DRAWING NUMBER DC -05 FROM TREMCO SEALANTS DRAWING NUMBER DC -08 OF 4 INCHES (102 mm) ON CENTER, FASCIA IPE VULKEM 345 OR 950NF PRIME w/ TREMPRIME INTERMEDIATE COAT ON -POROUS PRIMER VULKEM 350NF-R OR 360NF DYMERIC 240FC OR APPROVED BASE COAT TREMCO SEALANT CANT BEAD VULKEM 350NF-R OR 360NF VULKEM 346 OR 951 NF TOP COAT DETAIL COAT NOTE: VULKEM 950 NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. VULKEM TYPENETRATION - FROM TREATMENT OF FROM TREMCO SEALANTS DRAWING NUMBER DC -30 2 SEE DUALFLEX EMBEDDED IN BASE COAT 1 DRIP EDGE FLASHING: - VULKEM 351, 950NF OR 951 NF TOP COAT - ALUMINUM FASCIA - MECHANICALLY FASTENED FLUSH TO 'HARDIE BACKER BOARD ROOFS, AND SHALL OVERLAP A MINIMUM OF 3 INCHES (7 6 mm). EAVE AND PLYWOOD THE MANUFACTURER'S .INSTALLATION INSTRUCTIONS,. BEFORE 1/4" HARDIE BACKER BOARD o/ EXTERIOR WALL SHEATHING 3/4 EXTERIOR GRADE PLYWOOD EXTEND BACK ON THE ROOF FOR A MINIMUM OF 2 INCHES (51 mm). THE (INSTALLED A -SIDE UP AND MUST BE RING -SHANK / SCREWED INTO PLACE) 8 rF' BE (NOTE: WOOD SURFACES MUST PRIME) WITH VULKEM PRIMER ##171) ; OPTIONAL: DUALFLEX OR CLOTH TAPE - 1. FOR CLOSED VALLEYS: INSTALL PREFORMED CLOSED EMBEDDED IN VULKEM 350NF OR 5 /AY '' 36ONF DETAIL COAT WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE. DYMERIC 240FC OR APPROVED TREMCO WATER FROM T0SHED ER AW OM HOUSE » SEALANT CANT BEAD- 1" WIDTH 1/4" BACKER ROD (WRB) OVERLAPS THE 5x5 FLASHING 10 NOTE. ..VULKEM 950NF MAY BE .USED AS TOPCOAT IN AREAS WITH NO U.V. VULKEM TYPICAL EDG-NE DETAIL -2 FROM TREMCO SEALANTS DRAWING NUMBER DC -08 OF 4 INCHES (102 mm) ON CENTER, FASCIA JOINTS A MINIMUM 6" AND APPLY A COATING OR IPE VULKEM 345 OR 950NF PRIME w/ TREMPRIME INTERMEDIATE COAT ON -POROUS PRIMER VULKEM 350NF-R OR 360NF DYMERIC 240FC OR APPROVED BASE COAT TREMCO SEALANT CANT BEAD VULKEM 350NF-R OR 360NF VULKEM 346 OR 951 NF TOP COAT DETAIL COAT NOTE: VULKEM 950 NF MAY BE USED AS TOPCOAT IN AREAS WITH NO U.V. VULKEM TYPENETRATION - FROM TREATMENT OF FROM TREMCO SEALANTS DRAWING NUMBER DC -30 2 SEE 1 DRIP EDGE FLASHING: ELEV VALLEY FLASHING: A OF .TILED A DRIP ED SHALL E PROVIDED AT EAVES AND GABLES GE B E I ACCORDANCE WITH VALLEY LININGS SHALL BE INSTALLED N ACCO DA CE ROOFS, AND SHALL OVERLAP A MINIMUM OF 3 INCHES (7 6 mm). EAVE N THE MANUFACTURER'S .INSTALLATION INSTRUCTIONS,. BEFORE DRIP EDGES SHALL EXTEND \ INCH (13 mm) BELOW THE SHEATHING, AND EXTERIOR WALL SHEATHING APPLYING TILES. VALLEY LININGS OF THE FOLLOWING EXTEND BACK ON THE ROOF FOR A MINIMUM OF 2 INCHES (51 mm). THE KICK -OUT (WRB) WEATHER RESISTANT BARRIER .� DRIP EDGE SHALL BE MECHANICALLY FASTENED A MAXIMUM OF 6 (152 ROOFING ; F— III Lv—Im L� 1. FOR CLOSED VALLEYS: INSTALL PREFORMED CLOSED PER PLAN 2" 5 /AY '' VALLEY METAL EITHER A MINIMUM WIDTH OF 16 (24 WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE. WATER FROM T0SHED ER AW OM HOUSE » WHERE THE BASIC WIND SPEED PER FIGURE R301.2(4) IS 110 mph (177 >. HGT. PER PLAN (WRB) OVERLAPS THE 5x5 FLASHING 10 �<tz Q RIBBED DESIGN WITH 1" CENTER DIVERTER, A MINIMUM (4) 058 mm), DRIP EDGES SHALL BE MECHANICALLY FASTNED A MAXIMUM ROOF SHEATHING 3/8" RIBS SPACED 3 1/2" WITH 3 3/4" FLANGE. LAP OF 4 INCHES (102 mm) ON CENTER, FASCIA JOINTS A MINIMUM 6" AND APPLY A COATING OR INSTALL A MINIMUM 8" WIDE ANTI -PONDING METAL FLASHING TO HOLD BACK FASCIA ENSURE POSITIVE DRAINAGE OVER FASCIA/STARTER STRIP. NAIL 775; C_.) 2. FOR OPEN VALLEYS: INSTALL PREFORMED OPEN AND DRIP EDGE 2" d VALLEY WITH A MINIMUM OF 16" (24" STRETCH OUT) WITH THE UNDERLAYMENT SHALL CONFORM WITH ASTM D 226, TYPE f FROM FACE OF WALL { OR TYPE II, OR ASTM D 4869, TYPE I OR TYPE II. THE UNDER- MINIMUM 1" METAL EDGE RETURNS. LAP JOINTS A METAL DRIB' EDGE (9 F-- F MINIMUM 6" AND APPLY A COATING OR SEPARATOR OUTSIDE FACE OF .. SHEET: UNDERLAYMENT SHALL OVERLAP A MIMIMUM OF (19) INCHES AND - EXTERIOR WALL , • , BE MECHANICALLY FASTENED AT ( 36)IN HES O.C. MAXIMUM. SECURE WITH CLIPS FABRICATED FROM SIMILAR OR COMPATIBLE MATERIAL. CLIP 1" METAL EDGE RETURNS EXTERIOR FINISH TO BATTEN STRIP WITH 'ROOFING NAIL THROUGH METAL PER PLAN STRAP. ROOF PLAN DEPICTED BELOW IS FOR FASCIA +. B. TRIM METAL AT ALL VALLEY RID JUNCTIONS, VALLEY/RIDGE NOT REFLECT THE ACTUAL ROOF PLAN 1 ENSURING WATER SHEDDING CAPABILITIES ONTO THE OF THE RESIDENCE TO BE REPAIRED. 2„ 0 C. INSTALL LEAD SOAKER AT ALL VALLEY/RIDGE JUNCTIONS. TURN LEAD UP A MINIMUM OF 1„ TO CREATE A WATER DIVERTER, ENSURING WATER SHEDDING OUTSIDE rACE OF , 1 I I I I D. OUTER EDGE OF THE VALLEY' METAL SHALL EXTERIOR IWALL ,.. OVERLAP DECK FLANGE OF DRIP EDGE A MINIMUM OF 1 3 0 1 . CENTER OF VALLEY FLASHING SHALL EXTEND A MINIMUM OF 2” BEYOND DRIP EDGE. - - - 0 3 RIDGE FLASHING: 2 0 �) O 2 Q I O THE UNDERLAYMENT SHALL BE, INSTALLED IN WATER-SHEDING FASHION. THE LAST LAYER APPLIED AT THE RIDGE SHALL BE - SCALE: NTS KICK OUT FLASHING � ORACL:N ORACLE Engineering & Construction Services, Inc. 2714 Saint Johns Ave Jacksonville, FL 32205 (904) 518-5000 FL Cert. of Auth. No.: 30597 1 DRIP EDGE FLASHING: 2 0 VALLEY FLASHING: A OF .TILED A DRIP ED SHALL E PROVIDED AT EAVES AND GABLES GE B E I ACCORDANCE WITH VALLEY LININGS SHALL BE INSTALLED N ACCO DA CE ROOFS, AND SHALL OVERLAP A MINIMUM OF 3 INCHES (7 6 mm). EAVE N THE MANUFACTURER'S .INSTALLATION INSTRUCTIONS,. BEFORE DRIP EDGES SHALL EXTEND \ INCH (13 mm) BELOW THE SHEATHING, AND APPLYING TILES. VALLEY LININGS OF THE FOLLOWING EXTEND BACK ON THE ROOF FOR A MINIMUM OF 2 INCHES (51 mm). THE TYPES SHALL BE PERMITTED: DRIP EDGE SHALL BE MECHANICALLY FASTENED A MAXIMUM OF 6 (152 mm) INCHES O.C. THE DRIP EDGE AT EAVES SHALL BE INSTALLED F— III Lv—Im L� 1. FOR CLOSED VALLEYS: INSTALL PREFORMED CLOSED TH UNDERLAYMENT. THERE SHALL B A MINIMUM 4 INCH 102 mm OVER E U R E ( ) VALLEY METAL EITHER A MINIMUM WIDTH OF 16 (24 WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE. STRETCH 'OUT) WITH A MINIMUM 2 1/2" HIGH CENTER WHERE THE BASIC WIND SPEED PER FIGURE R301.2(4) IS 110 mph (177 DIVERTER AND A MINIMUM 1" METAL 'EDGE RETURNS OR A km/h) OR GREATER OR THE MEAN ROOF HEIGHT EXCEEDS 33 FEET (10 �<tz Q RIBBED DESIGN WITH 1" CENTER DIVERTER, A MINIMUM (4) 058 mm), DRIP EDGES SHALL BE MECHANICALLY FASTNED A MAXIMUM Q 3/8" RIBS SPACED 3 1/2" WITH 3 3/4" FLANGE. LAP OF 4 INCHES (102 mm) ON CENTER, JOINTS A MINIMUM 6" AND APPLY A COATING OR INSTALL A MINIMUM 8" WIDE ANTI -PONDING METAL FLASHING TO SEPARATOR SHEET. ENSURE POSITIVE DRAINAGE OVER FASCIA/STARTER STRIP. NAIL 775; C_.) 2. FOR OPEN VALLEYS: INSTALL PREFORMED OPEN TOP EDGE_ OF FLANGE ONTO ROOF. d VALLEY WITH A MINIMUM OF 16" (24" STRETCH OUT) WITH THE UNDERLAYMENT SHALL CONFORM WITH ASTM D 226, TYPE f A MINIMUM 1" HIGH TWIN CENTER DIVERTER AND A OR TYPE II, OR ASTM D 4869, TYPE I OR TYPE II. THE UNDER- MINIMUM 1" METAL EDGE RETURNS. LAP JOINTS A LAYMENT SHALL BE INSTALLED IN WATER-SHEDING FASHION, (9 F-- F MINIMUM 6" AND APPLY A COATING OR SEPARATOR STARTING WITH THE EAVE EDGE AND ROLLED HORIZONTALLY. SHEET: UNDERLAYMENT SHALL OVERLAP A MIMIMUM OF (19) INCHES AND - 3. WHEN USING VALLEY METAL WITH RETURNS: A. BE MECHANICALLY FASTENED AT ( 36)IN HES O.C. MAXIMUM. SECURE WITH CLIPS FABRICATED FROM SIMILAR OR COMPATIBLE MATERIAL. CLIP 1" METAL EDGE RETURNS NOTE: TO BATTEN STRIP WITH 'ROOFING NAIL THROUGH METAL STRAP. ROOF PLAN DEPICTED BELOW IS FOR ILLUSTRATION PURPOSES AND DOES � B. TRIM METAL AT ALL VALLEY RID JUNCTIONS, VALLEY/RIDGE NOT REFLECT THE ACTUAL ROOF PLAN 1 ENSURING WATER SHEDDING CAPABILITIES ONTO THE OF THE RESIDENCE TO BE REPAIRED. VALLEY. — — C. INSTALL LEAD SOAKER AT ALL VALLEY/RIDGE JUNCTIONS. TURN LEAD UP A MINIMUM OF 1„ TO CREATE A WATER DIVERTER, ENSURING WATER SHEDDING CAPABILITIES ONTO THE VALLEY. 1 I I I I D. OUTER EDGE OF THE VALLEY' METAL SHALL OVERLAP DECK FLANGE OF DRIP EDGE A MINIMUM OF 1 3 0 1 . CENTER OF VALLEY FLASHING SHALL EXTEND A MINIMUM OF 2” BEYOND DRIP EDGE. - - - 0 3 RIDGE FLASHING: 2 0 �) O 2 Q I O THE UNDERLAYMENT SHALL BE, INSTALLED IN WATER-SHEDING FASHION. THE LAST LAYER APPLIED AT THE RIDGE SHALL BE FOLDED OVER THE RIDGE AND MECHANICALLY FASTENED, AT (36) O.C. MAXIMUM TO THE OPPOSING SIDE. OF THE ROOF.: ,K REPEAT THE PROCEDURE FOR THE OPPOSING. SIDE OF THE I I ROOF. WHEN COMPLETED, THERE WILL BE TWO LAYERS OF 3 1 0 � o _ 4 0 UNDERLAYMENT OVERLAPPING THE RIDGE. E: HIP FLASHING: THE UNDERLAYMENT SHALL BE INSTALLED IN WATER-SHEDING 1 0 I FASHION. ON. AT THE HIP LINE, FOLD THE UNDERLAYMENT OVER. THE HIP AND MECHANICALLY FASTEN, AT 36INCH ES O.C. 1 O MAXIMUM TO THE. OPPOSING SIDE OF THE ROOF: REPEAT THE PROCEDURE FOR THE OPPOSING SIDE OF THE ROOF. WHEN 2O COMPLETED, THERE WILL BE TWO LAYERSOF UNDERLAYMENT 2 OVERLAPPING THE HIP, 5 a CRICKETS AND SADDLES FLASHING: 3 O a A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY GREATER THAN (30) INCHES (762 mm) — WIDE. CRICKET OR SADDLE COVERINGS -SHALL BE SHEET METAL OR OF THE SAME MATERIAL A S THE ROOF COVERING. 1, Q THE RIDGE AND VALLEY FLASHING OF CRICKETS OR SADDLES HA S LL BE THE SAME AS THE RIDGE AND VALLEY FLASHING ON THE MAIN ROOF. CJ6 BASE AND COUNTERFLASHING. ,; BASE AND COUNTER FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, OR A CONTINUOUS METAL MINIMUM 4 INCH BY 4 "L"' INCH FLASHING SHALL BE SET IN APPROVED FLASHING CEMENT AND SET FLUSH TO THE BASE OF THE WALL, AND OVER THE UNDERLAYMENT. BOTH HORIZONTAL ZONTAL AND VERTICAL METAL FLANGES SHALL BE FASTENED 6 INCHES (152 mm) ON CENTER WITH APPROVED FASTENERS. ALL LAPS SHALL BE A MINIMUM OF 4 INCHES (102 mm), FULLY SEALED IN APPROVED FLASHING CEMENT. FLASHING SHALL START AT THE LOWER PORTION OF THE ROOF TO ENSURE WATER SHEDING CAPABILITIES OF ALLMETALLAPS.. THE ENTIRE EDGE OF THE HORIZONTAL FLANGE SHALL BE SEALED, COVERING ALL NAIL PENETRATIONS WITH APPROVED FLASHING CEMENT AND MEMBRANE. SHINGLES SHALL OVERLAP THE HORIZONTAL FLANGE, AND SHALL BE SET IN APPROVED FLASHING CEMENT. BASE FLASHING SHALL BE OF EITHER CORROSION -RESISTANT METAL PROVIDED IN SECTION R905.2.8.1 OR MINERAL SURFACE ROLL ROOFING, WEIGHING A MINIMUM OF 77 POUNDS PER 100 SQUARE FEET (3.76 kg/M2). COUNTERFLASHING SHALL BE CORROSION- RESISTANT METAL WITH A MINIMUM THICKNESS PROVIDED IN TABLE 903.1 IN THE FLORIDA BUILDING CODE LASHING 5x 5 GALVANIZED DRIP EDGE " FSHING 'MET.AL FLA O1 26 GUAGE GALVANIZED 29 GUAGE GALVANIZED 26 G A E GALVANIZED 0" 0 (2015). N T.S N.T.S.N.TS. ROOF wZ KEYED FLASHING DETAILS SCALE: NTS ORACL:N ORACLE Engineering & Construction Services, Inc. 2714 Saint Johns Ave Jacksonville, FL 32205 (904) 518-5000 FL Cert. of Auth. No.: 30597 OFFICE COPY SHEET NO.: — S 7 Details JOB NO.: 17_40 SUBDIVISION: LOT NO.: ADDRESS: DESIGNED: AFL REVIEWED: AFL REVISIONS DATE �"y`s�,ry�a�yE�g944e8®�B�8P9AA8 tblpd�,� b A. b b No. 70791 a S ® TATE OF a per. t m-0C0RIVBa ANDRE�S�`®$ ° ` Ol!TRA PE # 70791 12/11/2017 I N N C) n .Q 0 F— III Lv—Im L� Li C.i Q~ = F - LL �<tz Q Q W I mF- Li Q 775; C_.) d Q i- LL C)z0 In Q >_ (9 F-- F �Q� OFFICE COPY SHEET NO.: — S 7 Details JOB NO.: 17_40 SUBDIVISION: LOT NO.: ADDRESS: DESIGNED: AFL REVIEWED: AFL REVISIONS DATE �"y`s�,ry�a�yE�g944e8®�B�8P9AA8 tblpd�,� b A. b b No. 70791 a S ® TATE OF a per. t m-0C0RIVBa ANDRE�S�`®$ ° ` Ol!TRA PE # 70791 12/11/2017 I