Loading...
2217 ALICIA LN - DECK & STUCCO REPAIR \�� CITY OF ATLANTIC BEACH - ''' "'' V800 SEMINOLE ROAD ,� v ATLANTIC BEACH, FL 32233 �r)st INSPECTION PHONE LINE 247-5814 RESIDENTIAL - ALTERATION RESIDENTIAL MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0112 Description: BALCONY DECK REPLACEMENT& STUCCO REPAIR Estimated Value: 500 Issue Date: 3/28/2018 Expiration Date: 9/24/2018 PROPERTY ADDRESS: Address: 2217 ALICIA LN RE Number: 169519 0760 PROPERTY OWNER: Name: MASHOD SIAMAC Address: 2217 ALICIA LN ATLANTIC BEACH, FL 32233-5975 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: Address: Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. p ?i , City of Atlantic Beach APPLICATION NUMBER & Building Department (To be assigned by the Building Department.) 800 Seminole Road r ( Atlantic Beach, Florida 32233-5445 R Gs —0 Phone(904)247-5826 Fax(904)247-5845 \\<_:...0;310- E-mail: building-dept@coab.us Date routed: 3 /2- A P-) City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 7.2- 17 P Ll C. ( A\ L/.) De. . . -nt review required Ye No ^^ !: ildin• v Applicant: CA7I\-_DE�� - a • Zoning Tree Administrator Project: 9 R LQ-C3 tp L E'L(L Public Works _ nn Public Utilities ( v CCO REP f}( 2._, Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: W pproved. Denied. I 'Not applicable (Circle one.) Comments: BUILDI G PLANNING &ZONING Reviewed by: trik-- Date: 126/2x' TREE ADMIN. Second Review: 'Approved as revised. Deni d. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. fNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 kirrikic Livr Building Permit Application Updated 12/8/17 y City of Atlantic Beach 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 l, Job Address: i .� —1 A L'Q . L.-n Permit Number: R w��&,- V( ( z, Legal Description RE# Valuation of Work(Replacement Cost)$ S`0d.cf‘'r Heated/Cooled SF ' Non-Heated/Cooled ---- - • Class of Work(Circle one): New Addition AlterationRepair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial ✓•eside ' -13 n _ • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: ` ���' �v: �' - ;$.147,9L i5'tr c' in c-U c_. t l — \ — ire�� 1 C t (Y?c?rl 5 eJ C.Z't" , , "f c fit C A C t% %DCS- i= J To - T/L>.,:.4 "f z di !L} Florida Product Approval# for multiple products use product approval form Property Owner Information Name: vnYYtaG ifYl(kSVLiC Address: '�� \--A +R .i C_: Ot, k--:VI City —l . c . State \--1.-- Zip 03 2,..1a.:3= Phone CC0q- ; IA --C l b E-Mail 5- 'on c Shc,c.s` Go Cc W Cr--S -• le C.• T Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: ,,G.s-n C, el_ ()\ i1C`(-Qualifying Agent: v Address City 7-- State Zip Office Phone Job Site/Contact Nu tr State Certification/Registration# E-Mail Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Exempt/Insu r/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the wor and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORD! G YOUR NOTF9 COMMENCEMENT. (Signat 1111P- (Signature-of Owner or Agent) (Signature of Contractor) (including contractor) 15 /' Signed and sworn todor affirmed bef. - me 4 is X? day of Signed and sworn to(or affirm d) before me this day of N,Aeck\ , a((1 , by a• vs'i.s'' , , b! ....� / `+..k GRACE MACKF .Ct,1ttle ' �• ,.�E'' MY COMMISSION#GG 642989( ,).nature of Notary) __ QQ`` (Signature of Notary) *' , '* EXPIRES:October 27,2020 -`'f,g1 }'VierskigttiroompoolkUnderwiters [ ]Personally Known OR .- , . r� � � / .` [ ]Produced Identification Ty.e o Identification: 1 l� Type of Identification: Ln-mt VUrT JS `; CITY OF ATLANTIC BEACH ,I ' 1 WNER / BUILDER AFFIDAVIT .P4 rilsa,- I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7),FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST60 SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE-OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING 0 MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. (y IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR W --,., ,, AFTER THE CONSTRUCTION IS COMPLETE, THE LAW WILL PRESUME THAT YOU BUILT V VD IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT Z U)\(y HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST < = ..1 Z BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS d V Z O M YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE O 174 LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING IZ LLI 0 LLj ORDINANCES. O m p Z F- II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIR Q THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BO O Q C `� PURCHASED. I- IL H co rtre Q W III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALS LLQ L OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEb 0 wQ a EMPLOY ON THEIR IMPROVEMENT TRADES. W W5 7 IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER AlV Ng U CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NCC a 455-228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALL > SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA "CONTRACTOR 1J CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. TELEPHONE TH BUILDING DEPARTMENT(247-5826) IF IN DOUBT. V.ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. \ `\ / q a n +/4Li. G C;i I---Y1 q O L\ Ul u\ - O Lk l( ADDRESS A PHONE NUMBER 1 Gl V1AC— (14‘;4 V47 L\ PRINT N ME I eV 3 231 ) � SIGNATURE DATE Before me this dC ld ay of I"lL-ft h ,20Jf in the county of Duval,State of Florida,has personally appeared herin by himself/herself and affirms that all statements and declarations are true and accurate. Notary Public at Large,State of 00:1 rlt. ,County of ►O CVGt.1 reduced Known /� ,, ` is/�Tn\� - -"t!y}F, oduced Identification- Ili fV�^'` (�{,�i1` ,I........V. GRACE MACKEY =r°' �, - MY COMMISSION#GG 042980 4 "" �' v 2 EXPIRES:October 27,2020 Notary Signature: .. ..";:•‘6-•••••04'i Bonded Thru Notary Public Undenwiters 4v • F:BLDG/Owner-Builder Affidavit;REVISED:4/16/2009 OFFICE COPY ICC Most Widely Accepted and Trusted EVALUATION SERVICE inCWjAHdIwn w,1J, L.Innovation LI RESEARCH LABS ICC-ES Evaluation Report ESR-1748 ICC-ES I (800)423-6587 I (562) 699-0543 I www.icc-es.org Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 24 00—EXTERIOR INSULATION AND FINISH SYSTEMS SECTION: 07 24 19—WATER-DRAINAGE EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: STO CORP. 3800 CAMP CREEK PARKWAY, BUILDING 1400, SUITE 120 ATLANTA, GEORGIA 30331 EVALUATION SUBJECT: STOTHERM° ci° ICC ICC ICC QLISTED Look for the trusted marks of Conformity! 4i1\ "2014 Recipient of Prestigious Western States Seismic Policy Council EMU (WSSPC)Award in Excellence" A Subsidiary of c groit eii SCC Ac.r.dit.d ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not �gPs specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a ANS/ recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ACCREDITED ISWIEC 17065 OCPS to any finding or other matter in this report, or as to any product covered by the report. Pr.d..,coN0a.onB0dY A«re6;teCCNJ x101 Copyright© 2017 ICC Evaluation Service, LLC. All rights reserved. ESICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1748 Reissued October 2017 This report is subject to renewal October 2018. www.icc-es.org I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE requirements of IBC Section 1408.4.1 and IRC Section PROTECTION R703.9 as EIFS with drainage. Section: 07 24 00—Exterior Insulation and FinishStoTherm® cr systems may be installed in buildings of Systems any construction type under the IBC (Types I through V) Section: 07 24 19—Water-Drainage Exterior Insulation and dwelling under the IRC when installed in accordance and Finish Systems with the applicable sections of Section 4.0. REPORT HOLDER: 3.0 DESCRIPTION 3.1 System Components: STO CORP. 3800 CAMP CREEK PARKWAY, BUILDING 1400, StoTherm®ci®systems consist of a water-resistive barrier, SUITE 120 adhesively applied flat insulation board, reinforcing mesh, ATLANTA, GEORGIA 30331 base coat, and finish coat. See Table 1 for system (800)221-2397 components. www.stocorp.com 3.2 Insulation Board: EVALUATION SUBJECT: The insulation boards must be one of the following: a. Expanded polystyrene (EPS) complying with ASTM STOTHERM®ci® C578, Type I, and ASTM E2430, produced by a molder with a current ICC-ES evaluation report. 1.0 EVALUATION SCOPE b. EPS insulation board produced by a molder who Compliance with the following codes: participates in an approved third-party quality- assurance program. EPS must comply with ASTM • 2015,2012 and 2009 International Building Code®(IBC) C578,Type I,and ASTM E2430. • 2015, 2012 and 2009 International Residential Code® c. Sto Insulation Board, EPS complying with ASTM (IRC) C578,Type I,and ASTM E2430. Properties evaluated: d. Dow Styrofoam Panel Core Type X recognized in ESR-2142 (for use with the StoTherm ci XPS system PROPERTY IBC IRC noted in Table 1). Chapter Chapter e. BASF Neopor® Rigid Foam Insulation Board (Grade Exterior insulation and finish 14 R7 F5300 Plus) recognized in ESR-3463 (for use with systems(EIFS) StoTherm ci Classic, StoTherm ci Premier, StoTherm Fire-resistance-rated construction 7 R3 ci Essence, and StoTherm ci Lotusan systems as Weather resistance 14 R7 noted in Table 1). Special inspections,Types I-IV 17 NA EPS insulation boards must have a flame spread (noncombustible)construction index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM Structural–transverse wind load 16 R6 E84 or UL 723. resistance 3.3 Substrates: Types I-IV(noncombustible) 26 NA construction Substrates must be one of the following: Surface burning characteristics 26 R3 a. Gypsum sheathing board complying with ASTM Ignition resistance 26 NA C1396 or ASTM C1177. When used as part of a fire-resistance-rated assembly, the gypsum board 2.0 USES must be Type X with a minimum thickness of 5/8 inch (15.9 mm). StoTherm® ci® systems are exterior insulation and finish systems (EIFS) complying with IBC Section 1408 and b. Concrete masonry complying with the code. IRC Section R703.9. The systems comply with the c. Concrete complying with the code. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as Wit to any finding or other matter in this report,or as to any product covered by the report. Nat ' ,e ...• Copyright©2017 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 5 ESR-1748 I Most Widely Accepted and Trusted Page 2 of 5 d. Exterior plaster complying with the code. minimum 10-foot (3048 mm) separation distance from e. Exterior or Exposure 1 wood structural panels adjacent construction. complying with DOC PS-1 or PS-2. 4.7 Special Inspection: 3.4 Sealants: For recognition under the IBC, special Inspections of the Sealants must comply with ASTM C920, Type S or M, water resistive barrier must be conducted in accordance minimum Grade NS, minimum Class 25 and Use O. with 2015 IBC Section 1705.16(2012 IBC Section 1705.15 and 2009 IBC Section 1704.14). Refer to STO Corp. third- 4.0 DESIGN AND INSTALLATION party inspection guidelines for verifying field preparation of 4.1 General: materials. StoTherm ci must be installed in accordance with the 5.0 CONDITIONS OF USE manufacturer's installation instructions, specifications and The StoTherm ci EIFS systems described in this report details,which are available at www.stocorp.com: comply with, or are suitable alternatives to what is http://www.stocorp.com/continuous-insulation-systems/ specified in,those codes listed in Section 1.0 of this report, • subject to the following conditions: • http://www.stocorp.com/sto systems/stothermci-xps- 5.1 Installation must comply with this report, the lotusan/ manufacturer's published installation instructions and • http://www.stocorp.com/sto systems/stothermci-classic/ the applicable code. In the event of a conflict between the manufacturer's instructions and this • http://www.stocorp.com/sto systems/stothermci-lotusan/ report,this report governs. • http://www.stocorp.com/sto systems/stothermci-xps- 5.2 The insulation board must be separated from the essence/ building interior by a thermal barrier complying with • http://www.stocorp.com/sto systems/stothermci-xps- the applicable code. classic/ 5.3 Installation must be by applicators listed by STO • http://www.stocorp.com/sto systems/stothermci- Corp. essence/ 5.4 Termination of the systems must not be less 4.2 Drainage: than 6 inches (152 mm) above finished grade in accordance with 2015 and 2009 IBC Section 2603.8 StoTherm ci provides drainage through the application of (2012 IBC Section 2603.9)and IRC Section R318.4. vertical ribbons of adhesive over the water-resistive barrier coating system identified in Table 1. 6.0 EVIDENCE SUBMITTED Additional installation and compliance information for the 6.1 Data in accordance with ASTM E2568 and ASTM StoGuard Gold Coat water-resistive barrier system is E2273. provided in ESR-1233 and at www.stocorp.com. 6.2 Data in accordance with the ICC-ES Acceptance 4.3 Wind Design: Criteria for EIFS Clad Drainage Wall Assemblies (AC235),dated January 2015. Table 3 presents specific StoTherm ci assemblies for which test data has been submitted. Other StoTherm ci 6.3 Data in accordance with the ICC-ES Acceptance assemblies may be considered for approval by local Criteria for Foam Plastic Insulation (AC12), dated officials, based on testing and/or calculations provided by a June 2015. qualified design professional. 7.0 IDENTIFICATION 4.4 Weather Protection: Each container or package of the coating or reinforcing StoTherm ci systems comply with IBC Section 1403.2 and mesh used as part of the StoTherm EIFS ci systems must IRC Section R703.1.1. be labeled with the manufacturer's name (STO Corp.)and 4.5 Use in Types I through IV (Noncombustible) address; the product name; lot or batch number; quantity of material; storage instructions; pot life; expiration date; Construction: and the evaluation report number(ESR-1748). Table 4 describes the assemblies qualified for use in Sto insulation board must be labeled on the edge of each Types I through IV construction(IBC). board with the STO Corp. name, the plant identification 4.6 Fire-resistance-rated Construction: number,and the evaluation report number(ESR-1748). Table 5 describes the assemblies qualified for use in Sto Turbostick adhesive must be labeled with the nonload-bearing fire-resistance-rated construction. Sto Corporation company name and product name In addition, in Type V construction, any StoTherm ci designation. system listed in this report may be attached to the surface Other foam plastic insulation must be labeled in of combustible exterior fire-resistance-rated assemblies accordance with the current ICC-ES evaluation report in described in 2015 and 2012 IBC Table 721.1(2) [2009 IBC which it is recognized, or in accordance with IBC Section Table 720.1(2)] without changing the assigned hourly 2603.2 or IRC Section R316.2, as applicable. rating of the assembly. The exterior wall must have a OFFICE COPY ESR-1748 I Most Widely Accepted and Trusted Page 3 of 5 TABLE 1—STOTHERM ci SYSTEM COMPONENTS" WATER- ASTM C578 SYSTEM RESISTIVE INSULATION ADHESIVES BASE COATS FINISH BARRIER BOARD TYPE StoGuard Gold Type I Sto BTS Plus Sto BTS Plus StoTherm ci Classic Coat Sto BTS Silo Sto BTS Silo Stolit (see ESR-1233) Sto BTS Xtra Sto BTS Xtra Sto TurboStick Sto RFP StoGuard Gold Type I Sto BTS Plus Sto BTS Plus StoTherm ci Premier Coat Sto BTS Silo Sto BTS Silo StoSilco Lit (see ESR-1233) Sto BTS Xtra Sto BTS Xtra Sto TurboStick Sto RFP StoGuard Gold Type I Sto Primer/Adhesive Sto DPR Sto Primer/Adhesive StoTherm ci Essence Coat Sto Primer/Adhesive-B Finish Sto Primer/Adhesive-B (see ESR-1233) Sto TurboStick Sto Guard Gold Type I Sto BTS Plus Sto BTS Plus StoTherm ci Lotusan Coat Sto BTS Silo Sto BTS Silo Stolit Lotusan (see ESR-1233) Sto BTS Xtra Sto BTS Xtra Sto TurboStick Sto RFP Sto Guard Gold Type X Sto BTS Plus StoTherm ci XPS Coat Sto TurboStick Sto BTS Xtra Stolit Sto Primer/Adhesive Stolit Lotusan (see ESR-1233) Sto Primer/Adhesive-B 'All base coats are reinforced with the appropriate Sto Mesh product listed in Table 2. 2Sto Primer is an optional component of the systems listed above. TABLE 2—REINFORCING MESH PRODUCTS PRODUCT NO. PRODUCT NAME' NOMINAL WEIGHT, oz/yd2(g/m2) 80920E Sto Mesh 4.5(153) 80919 Sto Detail Mesh 4.2(142) 80985 Sto 6-oz.(170 g)Mesh 6.0(170) 80918 Sto Intermediate Mesh 11.0(373) 80921 Sto Armor Mat 15.0(509) 80922 Sto Armor Mat XX 20.0(678) 80921A Sto Cornier Mat 7.6(258) 'Other listed mesh products may be used for detail construction or to supplement impact resistance of the EIFS. ESR-1748 I Most Widely Accepted and Trusted Page 4 of 5 TABLE 3—WIND LOAD DESIGN' WIND LOAD FRAMING MEMBERS' SHEATHING CAPACITY,psf (Pa) Metal Maximum SYSTEM Wood, Maximum Thickness Fastener min.size Min.Depth MinGage Spacing Type (inch) Spacing', Neg. Pos. . (inches) (inches) (inches) (inches) 2x4 _ Wood- 3 Classic (nominal) — 16 based /6 8 20 36 Premier Wood- -- 31/2 18 16 based 3/6 8 38 60 Essence Classic 31/2 18 16 Gypsum 112 8 20 35 PremierEssence Lotusan -- 31/2 18 16 Gypsum 5/8 8 38 60 Essence Classic Premier Essence Lotusan -- 6 18 16 Gypsum 5/8 6 40 50 (with Turbo Stick Adhesive and Type I EPS) -- 6 18 16 Gypsum 5/8 6 63 58 StoTherm ci XPS Classic Concrete or masonry substrates 54 54 Premier Lotusan For SI: 1 inch=25.4 mm,1 psf=0.0479 kPa. 'Applicable to all StoTherm materials listed in Tables 1 and 2. 2Deflection limitation 1/240,designed in accordance with applicable code. 'Fasteners must be No.6,flathead,corrosion-resistant screws[minimum 0.292-inch(7.4 mm)head diameter]. TABLE 4—ASSEMBLIES FOR USE IN TYPES I THROUGH IV CONSTRUCTION FRAMING MEMBERS5'8 INTERIOR SHEATHING''' EXTERIOR SHEATHING MAX. SYSTEM (TYPE X GYPSUM) (TYPE X GYPSUM) INSULATION BOARD Metal Max. Min. Max.Fastener Min. Max.Fastener THICKNESS, Min.Depth Min. Spacing Thickness Spacing Thickness Spacing (inches) (inches) Gage (inches) (inch) (inches) (inch) (inches) 8 at perimeter , 6 at perimeter 12 Essence 31/2 18 16 /z 12 in field2 /' 8 in field' , 4 s 6 at perimeter 12 Classic 3/2 18 166 /z 6 /e 8 in field' Premier Classic with Turbo Stick 3'/Z 18 166 5/8 8 at perimeter s/8 8 at perimeter 9 adhesive 12 in field 12 in field and Type I EPS StoTherm ci XPS with 31/2 18 166 5/8 8 at perimeter s/6 8 at perimeter 6 Sto BTS 12 in field 12 in field Xtra base coat and Stolit finish For SI: 1 inch=25.4 mm. 'All board joints backed by framing. 'Fasteners are minimum No.8,Type S,corrosion-resistant screws,with sufficient length to penetrate framing a minimum of 3/8 inch(9.5 mm). 'Fasteners are No.6 drywall screws having sufficient length to penetrate framing a minimum of 3/8 inch(9.5 mm). °Fasteners are No.6 by 11/4-inch-long(31.7 mm),buglehead drywall screws. 5Stud cavities at floor levels are blocked with Thermafiber insulation (as described in a current ICC-ES evaluation report),4 lb/ft3(64 kg/m3) density,4 inches(102 mm)thick and 2 feet(610 mm)wide. 6Stud cavities must be filled with R-11 fiberglass insulation. 'All joints must be taped and treated with joint compound. Intermediate fastener heads are treated with joint compound in accordance with ASTM C840 or GA216. 8Openings must be framed with minimum 0.0428-inch-thick steel framing. ESR-1748 I Most Widely Accepted and Trusted Page 5 of 5 TABLE 5—FIRE-RESISTANCE-RATED ASSEMBLIES1'2 FRAMING MEMBERS INTERIOR SHEATHING EXTERIOR SHEATHING MAXIMUM FIRESISTANCE E- EPS Min. Mi.n Max. Type Min. Max. Type Min. Max. INSULATION Depth Gage Spacing Thickness Fastener Thickness Fastener RATING BOARD (hrs) (inches) (inches) (inch) Spacing (inch) SpacingsTHICKNESS (inches) (inches) (inches) 8 o.c.on bat 1 31/2 18 16 Type X5 5/6 perimeter Type X 5/8 perimeter 4 gypsum 12 o.c.in gypsum 4 field3 8 in field Two layers Base layer Two layers Base layer 2 31/2 18 16 of Type X 5/8 at 24 o.c. of Type X 5/6 at 24 o.c. 4 5 Face layer Face layer gypsum at 8 o.c.6 gypsum at 8 o.c.6 For SI: 1 inch=25.4 mm. 'Applicable to all StoTherm ci materials listed in Table 1,except to StoTherm ci systems which use the Sto Turbo Stick adhesive. 2A11 board joints must be blocked 'Fasteners are minimum No.6, 11/4-inch-long(32 mm),self-tapping,corrosion-resistant bugle head screws. `Fasteners are No.6 drywall screws having sufficient length to penetrate framing a minimum of 3/6 inch(9.5 mm). 5lnterior wallboard joints must be covered with tape and joint compound.Interior fastener heads are covered with joint compound in accordance with ASTM C840 or GA 216. 6Fasteners for the base layer of gypsum board are No.6, 11/4-inch-long,self-tapping,corrosion-resistant bugle-head screws.Fasteners for the face layer are 17/5-inch-long,self-tapping,corrosion-resistant bugle-head screws. OFFICE COPY ESICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1748 FBC Supplement Reissued October 2017 This report is subject to renewal October 2018. www.icc-es.org I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 24 00—Exterior Insulation and Finish Systems Section: 07 24 19—Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: STO CORP. 3800 CAMP CREEK PARKWAY,BUILDING 1400,SUITE 120 ATLANTA,GEORGIA 30331 (800)221-2397 www.stocorp.com EVALUATION SUBJECT: STOTHERM®Cl® 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that StoTherm®Cl® systems, recognized in ICC-ES master evaluation report ESR-1748, have also been evaluated for compliance with the codes noted below. Applicable code editions: • 2014 Florida Building Code—Building • 2014 Florida Building Code—Residential 2.0 CONCLUSIONS The StoTherm®ci®systems, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1748, comply with the 2014 Florida Building Code—Building and 2014 Florida Building Code—Residential, provided the design and installation are in accordance with the International Building Code® (IBC) provisions noted in the master report under the following condition: Design wind loads must be based on Section 1609, using the load combinations of Section 1605.3, of the 2014 Florida Building Code—Building or the design wind loads in Section R301.2.1 of the 2014 Florida Building Code— Residential, as applicable. Use of the StoTherm® ci® for compliance with the High-Velocity Hurricane Zone provisions of the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential has not been evaluated and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity(or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report,reissued October 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service.LLC,express or implied,as i:til to any finding or other matter in this report,or as to any product covered by the report. ,LOU(,,, ,,,- Copyright©2017 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 1 APPLICATION INSTRUCTIONS laWATERPROOF DECK COATING-PLYWOOD SUBSTRATES MATERIALS 2. All plywood substrates are recommended to 1. 2.5 Hot Dipped lbs/sq yd Galvanized be sloped'/"per foot. Metal Lath (G90 is required in Inclement 3. Maximum deflection of the deck shall be Weather areas,refer to Technical less than L/360th of the span. Bulletin TB-110 Inclement Weather) 4. For additional application requirements in 2. Corrosion-resistant staples Inclement Weather areas, refer to 3. Pli-Dek Seam Paper Technical Bulletin TB-110. 4. GU80-1 Base Coat Powder(gray) 5. GU80-1 Top Coat Powder B. Plywood 6. GU80-1 Custom Top Coat 1. Plywood shall be a minimum of 16mm, 7. GU80-1 Liquid Admixture 5/8" (3/4" recommended) sound and dry, 8. GS88-1 Pigmented Sealer exposure 1 sheathing, and have a 9. Fiberglass Mat maximum span between supports of 10. PD Resin 410mm(16")on center. All plywood shall 11. GS13(Clear or Pigmented)or be securely fastened to the supports with PD Clear Sealer screws or ring shank nails spaced in accordance with APA guidelines and TOOLS Building Code requirements. 1. Variable Speed Drill(capable of 2. Framing or blocking must support all producing 1000 RPM's) plywood edges, except as per APA 2. Wind-lock B-M1 mixing blade or guidelines; blocking is not required when equivalent tongue and groove plywood is used. 3. Extension Cord 3. The plywood surface shall be clean, dry, 4. Clean 5 Gallon Plastic Containers and free of dirt, dust, oil, paint, or any 5. Measuring Bucket(1 gal, 2 gal, etc.) other contaminants that may impair 6. Hand Grinding Stone adhesion. 7. Level 4. All plywood seams shall be staggered, 8. Pencil and gapped 3.2mm (1/8"). All seams 9. Utility Knife shall be covered with a maximum of 10. Scissors 50mm (2")wide flashing paper tacked in 11. Masking Tape place. NOTE: If plywood is butted 12. 4"x 22"Pool Trowel tightly, the seams shall be saw cut to 13. Stainless Steel Trowel provide a 3.2mm (1/8") gap between 14. Margin Trowel sheets, except tongue&groove. Ensure 15. Small Paint Brushes that the tongue and groove section of the 16. Paint Roller(3/4"nap) plywood is installed so as to allow for 17. Extension Handle expansion. 18. Hopper Gun 5. All adjacent edges of the plywood sheets 19. Compressor(1-1/2 horsepower,electric shall not be more than 0.78mm (1/32") or better) out of plane (i.e. above or below each 20. Air Hose other). 21. Semi-stiff Broom 6. Plywood should be installed with a 22. Dust Mask 6.4mm/.3m (1/4") per linear foot slope. 23. Goggles Decks with parapet enclosures must be 24. Rubber or Cloth Gloves sloped to a drain or scupper. 25. Metal Spiked Golf Shoes 7. Any variation from the framing 26. Tin Snips specifications mentioned in section 1, 27. Hammer require written approval and system 28. Pneumatic Staple Gun recommendations from Pli-Dek Systems, 29. Hudson or Chapin Sprayer Inc. I. SUBSTRATE INSPECTION/PREPARATION C. Flashing *Refer to Pli-Dek Details A. General 1. Flashing shall be minimum 26 gauge, 1.Pli-Dek materials must be applied over galvanized, bonderized sheet metal. For sound dry exterior grade plywood decks. Inclement Weather areas,bonderized **Contact Pli-Dek Systems, Inc. for flashing is not recommended(refer to installation approvals over OSB substrates. Technical Bulletin TB-110 Inclement 4 Pli-Dek Systems,Inc. Waterproof Deck Coating-Pli Dek System 800.364.0287 Application Instructions PD-120 www.plidek.com Rev 05/19/2015 Page 1 of 6 Weather). Insure ALL metal flashing is wiped 3. If auxiliary slope is required, slope mix clean with a solvent to insure oils are may be applied. (See Sloping Application completely removed from the Surface. Instructions SM-120 for complete details Dissimilar metals;such as Copper and and limitations). When this type of galvanized, should NEVER come in direct sloping will not accommodate the contact with each other. problem, then drains become a 2. Openings shall be flashed before installation necessity. of doors and sliders. NOTE: If doors or 4. Pli-Dek requires a galvanized or sliders have been installed without proper stainless steel drain as per Drain Detail, flashing,we recommend they be removed PD-24, on all plywood installations. and proper flashing installed. Please contact Pli-Dek for help in 3. All penetrations,including posts,or other acquiring these drains. Do not use objects that protrude through the deck shall plastic, cast iron, or shower drains. If be installed and flashed prior to applying the copper drains are used, please contact Pli-Dek materials. Pli-Dek for instructions on dissimilar 4. All decks with a parapet surround require a metals. scupper not less than 76mm(3")wide,and 5. The alternatives available for proper 100mm(4")high, spaced a maximum of drainage are the responsibility of the 3.65m(12')apart. Any scuppers or General Contractor. Contact Pli-Dek overflows shall be installed and flashed prior Systems, Inc.for complete details. to applying Pli-Dek materials. 6. Pli-Dek Systems, Inc and/or trained 5. All deck drains must be flanged,and applicator will not be held responsible for properly installed to a proper depth.NOTE: ponding water or the effects resulting Brass drains with a sheet metal flange are from sloping installation. recommended. Pli-Dek requires a galvanized or stainless steel drain as per II.MIXING INSTRUCTIONS Drain Detail,PD-24, on all plywood All Pli-Dek products should be stored in a installations. Please contact Pli-Dek for help cool dry place at the jobsite to avoid flash in acquiring these drains. Do not use plastic, drying in the bucket. cast iron,or shower drains. If copper drains are used,please contact Pli-Dek for A. Base Coat instructions on dissimilar metals. 1. Pour 3,8L (1 gallon) of GU80-1 Liquid 6. Gravel stops shall have a maximum ground Admixture into a clean 19L (5 gallon) dimension of 3/16". plastic container. 7. All flashing must be attached to the substrate 2. Add one 21kg (461b.) bag of GU80-1 with galvanized ring shank nails a minimum Base Coat(gray), and mix thoroughly for 25mm(1")length. 3 to 4 minutes. Use a Wind-lock B-M1 8. All flashing shall overlap adjacent pieces, a mixing blade, or equivalent, powered by minimum of 100mm(4"),and seams caulked a 13mm (1/2") variable speed drill, with a Vulkem 931 Urethane sealant or capable of producing 1000 RPMs. TIP: equivalent. In areas subject to extremely dry and/or 9. Deck/Wall interfaces must be flashed. hot climates, it may be necessary to add 10. All stairs must be flashed. water (up to .47L [1 pint] per mix). To 11. When copper flashing/drains are used, avoid flash drying, it may be necessary ensure that all galvanized metal;such as, to chill the GU80-1 Liquid Admixture nails,staples, lath,drains, etc.does not before mixing. A proper safety come into contact with copper(do not allow ventilation mask should be worn when any dissimilar metals to come in contact with working with all Pli-Dek products. each other).The contact of the two dissimilar metals will create rust and corrosion B. Screed Coat&Knockdown Texture Coating (electrolysis). "Contact Pli-Dek Systems, 1. Pour 4.75L (1.25 gallon) of GU80-1 Inc.for additional details and Liquid Admixture into a clean 19L (5 recommendations. gallon)plastic container. 12. See Pli-Dek Details for further written 2. Add one 21kg(461b.)bag of GU80-1 Top instructions.Contact Pli-Dek Systems, Inc Coat and mix thoroughly for 3 to 4 for written approval on flashing details that minutes. Use a Wind-lock B-M1 mixing vary or are not included in Pli-Dek Details. blade, or equivalent, powered by a D. Sloping 13mm (1/2") variable speed drill capable 1. It's the General Contractor's, his of producing 1000 RPMs. TIP: In areas representative's, or individual owner's subject to extremely dry and/or hot responsibility to assure adequate climates, it may be necessary to add drainage. water (up to .47L [1 pint] per mix). To 2. All plywood substrates are avoid flash drying, it may be necessary recommended to be sloped of 1/4" per to chill the GU80-1 Liquid Admixture, foot. before mixing. A proper safety 4WatePli-Dek Systems,Inc. rproof Deck Coating Pli-Dek System 800.364.0287 Application Instructions PD-120 www.plidek.com Rev 05/19/2015 Page 2 of 6 ventilation mask should be worn when DECK PLAN in the Pli-Dek Detail working with all Pli-Dek Products. Appendix.) 3. If colored cement is required, a Pli-Dek 4. Secure metal lath to plywood with a recommended tint pack may be added to minimum 22mm (7/8") crown by a the mix to achieve the desired color. minimum 16mm (5/8") long corrosion Note: ensure that all of the colorant is resistant staples spaced approximately dispersed out of the container. All mixes 11/2" on center around the perimeter and must be consistent (use the same mix on overlapped lath seams, and 75mm ratios)to maintain color consistency. (3")in the field (approximately 12 staples per square foot). C. Custom Top Coat 5. Additional staples spaced every 1'/z" on 1. Pour 4.75L (1.25 gallon) of GU80-1 center are required where the metal lath Liquid Admixture into a clean 19L (5 overlaps the seam paper, as installed in gallon)plastic container. Section I. 2. Add one 21kg (461b.) bag of GU80-1 Custom Top Coat and mix thoroughly for C. Base Coat Application 3 to 4 minutes. Use a Wind-lock B-M1 1. Mix the GU80-1 Base Coat as described mixing blade, or equivalent, powered by in Section II—A. a 13mm (1/2") variable speed drill 2. Pour the GU80-1 Base Coat over the capable of producing 1000 RPMs. TIP: metal lath and trowel, filling all voids at a In areas subject to extremely dry and/or rate of 25 - 30 square feet per mix. The hot climates, it may be necessary to add metal lath must be completely covered in water (up to .47L [1 pint] per mix). To the Base Coat. avoid flash drying, it may be necessary 3. Allow the GU80-1 Base Coat to dry for a to chill the GU80-1 Liquid Admixture minimum of 6 hours prior to applying the before mixing. A proper safety next application. If the base coat does ventilation mask should be worn when not cover the lath completely, a screed working with all Pli-Dek products. coat is required. 3. If colored cement is required, a Pli-Dek recommended tint pack may be added to D. Screed Coat Application the mix to achieve the desired color. 1. Screed coat may not be necessary in all Note: Ensure that all of the colorant is applications. Contact Pli-Dek Systems, dispersed out of the container. All mixes Inc. for application details and must be consistent (use the same mix recommendations. ratios)to maintain color consistency. 2. Prior to the screed coat application, remove any high or rough edges using a Ill. BASE&SCREED COAT hand grinding stone or scraper. 3. The deck must be free of all surface A.General contaminants, such as dust, dirt, etc., 1. Ensure that the exterior plywood surface which will impair the adhesion of the Pli- has been prepared in accordance with Dek GU80-1 Top Coat. Section I. 4. Mix the GU80-1 Top Coat as described 2. Ensure that all proper flashing is in place. in Section II—B. 3. Air temperature for application of the 5. Trowel a screed coat over the base coat Base Coat must be between 10°C (50°F) at a rate of 150 square feet per mix. and 43°C(110°F)and must remain so for Allow to dry for a minimum of 2-6 hours. a minimum of 2 - 6 hours. Ensure humidity levels are low. Do not apply E. Pli-Dek—"F": Fiberglass&Resin over moisture. **This application becomes required when job conditions may experience excessive B. Plywood Deck Preparation movement. Examples:cantilevered decks, 1. Lay out 2.5 hot dipped lbs per square large spanning decks,etc. Contact Pli-Dek yard Galvanized Metal Lath in a Systems, Inc.for written recommendations. staggered pattern over the entire Some geographic locations may require the plywood surface overlapping the metal Fiberglass and Resin Coating in ALL flashing,to the edge of the deck surface. applications.Contact Pli-Dek Systems, Inc for G90 galvanized metal lath is required in written verification. Inclement Weather areas (refer to 1. Air temperature for application of the PD Technical Bulletin TB-110 Inclement Resin and Fiberglass Coat must be Weather) between 10°C (50°F) and 43°C (110°F) 2. Overlap all edges of metal lath, a and must remain so in the acceptable minimum of 13mm(3/4"). range until the product has cured. 3. Offset metal lath edges a minimum of 2. Mix the PD Resin using a mechanical 150mm (6") from plywood seams. (See mixer at slow speed for approximately 1 minute. 4WatePli-Dek Systems,Inc. rproof Deck Coating—Pli-Dek System 800.364.0287 Application Instructions PD-120 www.plidek.com Rev 05/19/2015 Page 3 of 6 OFFICE COPY 3. The deck must be free of all surface 4. Air temperature for application of the contaminants, such as dust, dirt, etc., GS88-1 Sealer must be between 13°C which will impair the adhesion of the PD (55°F) and 43°C (110°F) and must Resin. remain in acceptable range until the 4. Lay out the .75 oz fiberglass mat over product has fully cured. Ensure humidity entire deck surface extending to all levels are low. Do not apply over edges of the deck. Overlap mat seams a moisture. minimum of 1/4"to a maximum of 1/2". 8. The deck must be free of all surface 5. Apply the PD Resin over fiberglass mat, contaminants, such as dust, dirt, etc., at a rate of approximately 40 -50 square which will impair adhesion of the GS88-1 feet per gallon with a trowel. Allow to Sealer. completely dry, usually 6 - 8 hours 9. Mix the GS88-1 Sealer thoroughly by depending on temperature. PD Resin mixing with the use of a mechanical must completely penetrate through the mixer. All containers should be boxed fiberglass mat. and stirred to ensure consistent coloring 6. After the PD Resin has cured, remove throughout. any loose areas, where fiberglass was 10. Apply the GS88-1 Sealer over the dry not bonded, and reapply PD Resin and Knockdown Coat, using a 19mm (3/4") Fiberglass as needed before application nap paint roller, suitable for latex type of Finish Coat. coatings at a rate of 100 square feet per gallon(2 coats may be necessary). IV. FINISH OPTIONS 11. To make cleaning easier in high traffic Prior to any finish coat installation the following areas, a coat of GS13 or PD Clear must be completed: Sealer may be applied over the dry 1. Remove any high or rough areas using GS88-1 Pigmented Sealer at a rate of hand grinding stone or scraper. Rough 200 square feet per gallon. (Surface will areas will affect the aesthetic become more slippery. Use of a non- appearance of the finished product. skid agent is recommended) 2. The deck must be free of all surface contaminants, such as dust, dirt, etc., B. ELASTOMERIC SAND FINISH which will impair the adhesion of the Pli- 1. Air temperature for application of the PD Dek material. Ensure humidity levels are Resin must be between 10°C (50°F)and low. Do not apply over moisture. 43°C (110°F), and must remain so for a minimum of 8 hours. Do not apply over A. KNOCKDOWN TEXTURE FINISH any moisture. 1. Air temperature for application of the 2. Apply a bead of manufacturer's Knockdown Texture Coating mixture recommended elastomeric joint sealant must be between 10°C (50°F) and 43°C at all wall-to-deck junctions, wood posts, (110°F) and must remain so in wrought iron posts, etc. acceptable range until the product has 3. Before application, mix PD Resin using a fully cured. mechanical mixer at slow speeds; mix 2. Mix the GU80-1 Top Coat as described thoroughly until a homogenous mixture in Section II—B. and color is obtained. Use care not to 3. Using a hopper gun, spray the allow the entrapment of air into the Knockdown Coating over.the entire deck mixture. surface at a rate of 150—sq ft per mix. 4. Apply PD Resin over the entire deck CAUTION: AS WITH ANY SPRAY surface and flashing using a 3/<" nap MATERIAL, BE CERTAIN TO roller and a brush at a rate of 75 square PROTECT ALL SURROUNDING feet per gallon. Do not allow PD Resin to AREAS FROM OVER-SPRAY. puddle. 4. When the material begins to dry, 5. Broadcast aggregates of washed, dry, knockdown the material with a trowel. rounded, crystal silica sand, TIP: In order to eliminate footprints, we approximately 16 mesh at a rate of 100 suggest wearing metal spiked shoes lbs. per 100 square feet or until refusal (golf shoes)during this process. (depending on skid resistance 5. Allow the Knockdown Coating to dry a requirements) into the wet/uncured PD minimum of 2-6 hours. Resin. 6. Remove any sharp edges by scraping 6. Allow a minimum of 8 hours before the surface with a scraper or trowel. removing all excess silica sand. Ensure surface is free from dust and/or 5. Air temperature for application of the contaminates. GS88-1 Sealer must be between 13°C 7. Apply a bead of Pli-Dek's recommended (55°F) and 43°C (110°F) and must be elastomeric joint sealant at all wall-to- allowed to dry for a minimum of 8 hours. deck junctions,wood posts, wrought iron Ensure humidity levels are low. Do not posts,etc. apply over moisture. ® Pli-Dek Systems,Inc. Waterproof Deck Coating—Pli-Dek System 800.364.0287 Application Instructions PD-120 www.plidek.com Rev 05/19/2015 Page 4 of 6 OFFICE COPY 7. The deck must be free of all surface 3. Trowel a second coat of GU80-1 Gray contaminants, such as dust, dirt, etc., Base over the entire deck surface at a which will impair adhesion of the GS88-1 rate of 150 square feet per mix. While Sealer. the second coat is wet/uncured, 8. Mix the GS88-1 Sealer thoroughly by broadcast aggregates of washed, dry, boxing, stirring,or by using a mechanical rounded, crystal silica sand mixer. Box and mix all containers to approximately 16 mesh at a rate of ensure consistent coloring throughout. 1001bs. per 100 square feet, or until 9. Apply the GS88-1 Sealer over the dry PD refusal (depending on skid resistance Resin and Sand Coat, using a 19mm requirements) (3h") nap paint roller, suitable for latex 4. Allow drying for 6 hours before removing type coatings (2 coats may be all excess silica sand. A proper necessary.) ventilation mask should be worn at all 10. To make cleaning easier in high traffic time when working with Pli-Dek products. areas, a coat of GS13 or PD Clear 6. Air temperature for application of the Sealer may be applied over the dry GS88-1 Sealer must be between 13°C GS88-1 Pigmented Sealer at a rate of (55°F) and 43°C (110°F) and must 200 square feet per gallon. (Surface will remain dry for a minimum of 8 hours. become more slippery. Use of a non- Ensure humidity levels are low. Do not skid agent is recommended) apply over moisture. 5. The deck must be free of all surface C. Pli-Dek—"U": UNDERLAYMENT FOR contaminants, such as dust, dirt, etc., TILE OR CONCRETE FINISH which will impair adhesion of the GS88-1 Note:The vertical leg of all flashings should be Sealer. coated with Fiberglass and PD Resin. 6. Mix the GS88-1 Sealer thoroughly by 1. Air temperature for application of the PD mixing with the use of mechanical mixer. Resin must be between 10°C (50°F)and Box mix all containers to ensure 43°C (110°F), and must remain so for a consistent coloring throughout. minimum of 8 hours. Do not apply over 7. Apply the GS88-1 Sealer at a rate of 75- any moisture. 100 square feet per gallon depending on 2. Apply a bead of Pli-Dek's recommended thickness of Sand Coat, using a 19mm elastomeric joint sealant at all wall-to- (3/4") nap paint roller, suitable for latex deck junctions,wood posts, wrought iron type coatings (2 coats may be posts,etc. necessary). 3. The vertical leg of all flashings should be 8. To make cleaning easier in high traffic coated with Fiberglass and PD Resin. areas, a coat of GS13 or PD Clear 4. PD Resin should not be exposed to Sealer may be applied over the dry construction traffic. GS88-1 Pigmented Sealer at a rate of 5. Mix the Pli-Dek GU80-1 Top Coat as 200 square feet per gallon. Surface will described in II-A. become more slippery, use of a non — 6. Apply a screed coat of GU80-1 Top Coat skid agent is recommended. over the entire deck at a rate of 150 square feet per mix. Allow to dry for a E. POLYACRYLIC SMOOTH FINISH minimum of 2 - 6 hours. Mix the GU80-1 1. Air temperature for application of the Top Coat as described in Section II—B. Polyacrylic smooth finish must be 7. Allow a minimum of 8 hours prior to between 10°C (50°F) and 43°C (110°F) installing any finished product over the and must remain so for a minimum of 8 PD Resin and sand surface or screed hours. It may be necessary to grind the coat. rough ridges of the Base Coat to 8. *Optional: Broadcast aggregates of washed, minimize chatter lines. dry, rounded crystal silica sand, 2. Mix the GU80-1 Top Coat as described approximately 16 mesh, at a rate of 100Ibs. in Section II—B. per 200 square feet. 3. Trowel a screed coat over the entire deck surface at a rate of 150 square feet D. POLYACRYLIC SAND FINISH per mix. Allow it to dry for a minimum of 1. Air temperature for application of the Pli- 6 hours. Dek C finish must be between 10°C 4. It may be necessary to apply an (50°F) and 43°C (110°F) and must additional coat of GU80-1 Custom Top remain in acceptable range until product Coat to create a smoother finish. has fully cured. Coverage rate should be approximately 2. Mix the GU80-1 Gray Base Coat as 200 square feet per mix. **Please note: described in Section II - A and add an Surface will not be perfectly smooth and additional 1/2 gallon of GU80-1 Liquid will have some imperfections/variations. Admixture. 5. Apply a bead of Pli-Dek recommended elastomeric joint sealant to all wall-to- 4 Pli Dek Systems,Inc. Waterproof Deck Coating—Pli-Dek System 800.364.0287 Application Instructions PD-120 www.plidek.com Rev 05/19/2015 Page 5 of 6 OFFICE COPY deck junctions, wood posts, wrought iron 7. Trowel a tinted screed coat over the posts,etc. stenciled or taped deck surface at a rate 6. Air temperature for application of the of 150 square feet per mix. Allow to dry GS88-1 Sealer must be between 13°C for a minimum of 2-6 hours. (55°F) and 43°C (110°F) and must 8. Apply desired stain/shading using a low remain dry for a minimum of 8 hours. pressure sprayer, soft broom, or sponge. Ensure humidity levels are low. Do not Contact Pli-Dek Systems, Inc. for apply over moisture. complete details. 7. Prior to color coat application, remove 9. Remove the stencil or tape pattern. any high or rough edges using a hand 10. The deck must be free of all surface grinding stone or scraper. contaminants, such as dust, dirt, etc., 8. The deck must be free of all surface which will impair adhesion of the GS13 contaminants, such as dust, dirt, etc., or PD Clear Sealer. which will impair adhesion of the GS88-1 11. Apply a coat of GS13 or PD Clear Sealer Sealer. at a rate of 200 square feet per gallon. 9. Mix the GS88-1 Sealer thoroughly by (2 coats may be necessary.) mixing with the use of a mechanical mixer. Box mix all containers to ensure H. Slip and Fall Precautions consistent coloring throughout. 1. OSHA, American Disabilities Act (ADA), and 10. Apply the GS88-1 Sealer using a 19mm The Federal Housing Act (FHA) have now (3/4") nap paint roller, suitable for latex set enforceable standards for slip-resistance type coatings, at a rate of 100 square on pedestrian surfaces. Pli-Dek Systems, feet per gallon (2 coats may be Inc. recommends the use of angular slip- necessary). resistant aggregate in all coatings or flooring 11. To make cleaning easier in high traffic systems that may be exposed to wet, areas, a coat of GS13 or PD Clear oily/greasy, or otherwise potentially slippery Sealer may be applied over the dry conditions. It is the end users responsibility GS88-1 Pigmented Sealer at a rate of to provide a flooring system that meets 200 square feet per gallon. (Surface will current safety standards. Pli-Dek Systems, become more slippery. Use of a non-skid Inc or its sales agents will not be responsible agent is recommended.) for injury incurred in a slip and fall accident. Please consult local building codes for the F. EPDXY STONE FINISH current coefficient of friction requirement. *Contact Pli-Dek Systems, Inc.for written instructions. Disclaimer Information contained in this specification G.CUSTOM FINISH:SIMULATED TILE,BRICK, conforms to standard detail and product AND STONE recommendations for the installation of the 1. Air temperature for application of the Pli-Dek products as of the date of publication Custom Finish must be between 10°C of this document and is presented in good (50°F) and 43°C (110°F) and must faith. Pli-Dek Systems, Inc. assumes no remain so for a minimum of 8 hours. liability, expressed or implied, as to the 2. Mix the GU80-1 Custom Top Coat as architecture, engineering or workmanship of described in Section II - C and add the any project. To insure that you are using the selected color tint pack to establish the latest, most complete information, contact desired grout color. Note: All mixes Pli-Dek Systems, Inc.at: must be consistent (use the same mix ratios)to maintain color consistency. 41610 Date St,Suite 104 3. The deck must be free of all surface Murrieta, CA 92562 contaminants, such as dust, dirt, etc., Tel.:(800)364-0287 which will impair adhesion of the GU80-1 Website: www.plidek.com Custom Top Coat. 4. Trowel a tinted GU80-1 Top Coat over * The Trained Applicator indicates certain the entire deck surface at a rate of 150 employees of the company have been square feet per mix. Allow to dry for a instructed in the proper application of Pli-Dek minimum of 2 - 6 hours. (Decorative products and have received copies of the Pli- scroll lines can be achieved at this step Dek Application Instructions and prior to screed coat drying,as long as no Specifications. The Trained Contractor templates or tape are going to be used.) Program is not an apprenticeship. Each 5. Install one of the various types of stencil trained contractor is an independent patterns or install a tape pattern over the company and bears responsibility for its own cured screed coat to achieve the desired workmanship. Pli-Dek Systems Inc. finish. assumes no liability for the workmanship of a 6. Mix the GU80-1 Custom Top Coat as in trained contractor. Section II—C. 4 Pli-Dek Systems,Inc. Waterproof Deck Coating—Pli-Dek System 800.364.0287 Application Instructions PD-120 www.plidek.com Rev 05/19/2015 Page 6 of 6