Loading...
1614 MARITIME OAK DR - RES17-0300 y y.(OLA f `; CITY OF ATLANTIC BEACH ss1 800 SEMINOLE ROAD Vr ATLANTIC BEACH, FL 32233 L) INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0300 Description: new single-family home Estimated Value: 375503.1 Issue Date: 2/2/2018 Expiration Date: 8/1/2018 PROPERTY ADDRESS: Address: 1614 MARITIME OAK DR RE Number: 169505 1960 PROPERTY OWNER: Name: SH DESIGN LLC Address: 830 3rd ST UNIT 101 JACKSONVILLE BEACH, FL 32250 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: SH DESIGN LLC Address: 830 3Rd ST UNIT 101 JACKSONVILLE BEACH, FL 32250 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. ',ir�`1Y r 1,� ._ r _ Permit Conditions •is City of Atlantic Beach -.,A)? Permit Number: RES17-0300 Description: new single-family home Applied: 12/6/2017 Approved: 1/23/2018 Site Address: 1614 MARITIME OAK DR Issued:2/2/2018 Finaled: City,State Zip Code:ATLANTIC BEACH, FL 32233 Status: ISSUED Applicant:<NONE> Parent Permit: Owner:SH DESIGN LLC Parent Project: Contractor:<NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 12/13/2017 EROSION CONTROL INSTALLATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(247- 5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 2 12/13/2017 ON SITE RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site during construction. 3 12/13/2017 ROLL OFF CONTAINER INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapell's,Inc., Republic Services,Donovan Dumpsters). Container cannot be placed on City right-of-way. 4 12/13/2017 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. 5 12/13/2017 RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site. Cannot raise lot elevation. Printed: Friday,02 February, 2018 1 of 2 r /�-LYf S rill" ri, Permit Conditions 'r ,. City of Atlantic Beach 6 12/13/2017 MAXIMUM DRIVEWAY INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Maximum driveway width within the City right-of-way is 20'. 7 12/13/2017 ADDITIONAL COMMENTS PUBLIC INFORMATIONAL WORKS PUBLIC WORKS Scott Williams Notes: A Revocable Encroachment Permit must be obtained if using pavers in driveway. 8 12/13/2017 ADDITIONAL COMMENTS PUBLIC INFORMATIONAL WORKS PUBLIC WORKS Scott Williams Notes: .: , .n n,, 4 r ,-,,= t.� .�z-. i.. ,?'k,s, .;s '-.4, z,at€;" "?7fz*.r. T.ttmiFis: '*¢ `--?,.. ,.. .. + 3+. (Concrete sidewalk must continue through driveway at correct slope(2%or less). - ecr31.,4 �_ 9 12/8/2017 UNDERGROUND WATER SEWER INFORMATIONAL UTILITIES PUBLIC WORKS Kayle Moore Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5834. 10 12/8/2017 METER BOX SEWER CLEAN OUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible. 11 12/8/2017 RT1 SEWER CLEANOUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to ,grade and visible. Printed: Friday,02 February, 2018 2 of 2 • w V Cash Register Receipt Receipt Number City of Atlantic Beach R4128 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $7,974.80 RES17-0300 Address: 1614 MARITIME OAK DR APN: 169505 1960 $7,974.80 BUILDING $1,308.00 BUILDING PERMIT 455-0000-322-1000 0 $1,308.00 BUILDING PLAN REV RESUBMITTALS $150.00 BUILDING PLAN REVIEW RESUBMITTAL 45500003221006 0 $50.00 SECOND BUILDING PLAN REVIEW RESUBMITTAL 45500003221006 0 $50.00 SECOND BUILDING PLAN REVIEW RESUBMITTAL 45500003221006 0 $50.00 SECOND BUILDING PLAN REVIEW $654.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $654.00 PUBLIC UTILITIES $5,610.00 CROSS CONNECTION 400-0000-343-3701 1 $50.00 WATER SYSTEM DEVELOPMENT IMPACT 415-0000-324-0301 1 $1,140.00 L CHARGE SEWER SYSTEM DEVELOPMENT CHARGE 415-0000-324-0301 1 $4,050.00 WATER METER ONLY DOMESTIC 400-0000-343-3301 0 $185.00 WATER METER ONLY RECLAIM 400-0000-343-3301 0 $185.00 PUBLIC UTILITIES PLAN REVIEW $50.00 PU REVIEW RESIDENTIAL BLDG 001-0000-329-1007 0 $50.00 PUBLIC WORKS PLAN REVIEW $100.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE SURCHARGES $52.80 STATE DCA SURCHARGE 45500002080700 0 $21.12 STATE DBPR SURCHARGE 455-0000-208-0600 0 $31.68 ZONING PLAN REVIEW $50.00 ZONING REVIEW SINGLE AND TWO FAMILY 001-0000-329-1003 0 $50.00 USES TOTAL FEES PAID BY RECEIPT: R4128 $7,974.80 Date Paid: Friday, February 02, 2018 Paid By: SH DESIGN LLC Cashier: CB Pay Method: CHECK 2505 Printed: Friday, February 02,2018 4:06 PM 1 of 1 1 TMT �-0..M:.�� City of Atlantic Beach APPLICATION NUMBER Js •.e>sl Building Department (To be assigned by the Building Department.) ; 800 Seminole Road ,( - 0300 js -e Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 • Fax(904)247-5845 f^ J;; �� E-mail: building-dept@coab.us Date routed. Ia L l0 l 1 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: tk1)I q OOt Q1 . Department review required Yes No uilding� Applicant: 5 O S1 q (\ LL� Planning &Zoning j �.1 Tree Administrator Project: (\-Lu.) S�f1f�lQ— (Ylty VOrnk_ P blic Works �J lic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 'Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: :UILDING PLAN 1 &ZONING Reviewed by: Date: TREE ADMIN. Second Review: Approved as revised. ['Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: r<Dproved as revised. ['Denied. ['Not applicable Comments: Reviewed by: r Date: /- ,)0/s' Revised 05/19/2017 r_ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ;r COPY BEACH,FL 32233 OFFICE COPY (904)247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 1.9.2018 Permit#: RES17-0300 Applicant: SH Design,LLC Site Address: 1614 Maritime Oaks Dr. Site Address: 830 3rd St.,#101,Jax Bch. Review: 2 Phone: 755.5393 RE#: 169505-1960 Email: bmessinana shdesigniax.com Homeowner: same CORRECTION COMMENTS: These are review comments from 1 of 4 departments reviewing this permit application. 1. Revi • s need to be clouded and labeled with short narrative in ISIONS box. Pick up revised pages and correct or submit new ones wi the clouding and labeling. Mike Jones Building Inspector/Plan Reviewer City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 Fax (904) 247-5845 e'a ;1 d Revs %or GZevC )--- " A-4--T /—R - 261� i 1 s CITY OF ATLANTIC BEACH s-. `",_ ,.+ 800 SEMINOLE ROAD tilif ATLANTIC BEACH,FL 32233 (904)247-5800 \J;31 9't- BUILDING DEPARTMENT REVIEW COMMENTS Date: 12.18.2017 Permit#: RES17-0300 Site Address: Jax Beach Site Address: 1614 Maritime Oak Dr. Phone: 755.5393,424.9652 Review: 1 Email: bmessina@shdesignjax.com RE#: 169505-1960 Homeowner: Same, jspalten@shdesignjax.com Applicant: SH Design,LLC CORRECTION COMMENTS: These are review comments from 1 of 4 departments reviewing this permit application. 1. The energy calculation information submitted is missing the Manual S Compliance Report. 2014 5th Edition of the FBC-Energy Conservation, R403.6,R403.6.1. Submit 2 copies. Mike Jones (LI\'PRMIA) Building Inspector/Plan Reviewer City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 Fax (904) 247-5845 1 1 ,.<4,7,:1,t;-40:-'—i t+l1)y�� 'i �► CITY OF ATLANTIC BEACH A JAN - 3 2016 800 Seminole Road dttik,aaw a Atlantic Beach,Florida 32233 ` , OFFICE COPY REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS e 65 Date i/S/ / 5 Revision to Issued Permit Corrections to Comments Per # I 1 - 03 00 Project Address / ‘ /(1 1V)acr, ,vs C co/c Pc. Contractor/ Contact Name c!T Oe...50 vk Z-4-C- r 712/$9c'\ /1/16-53/C'/4 Phone qc y— lag- ?C'5.-Z- Email 6 I fr.SS2N'9 e S H 0t--s/)vi j yx, (Li- Description wDescription of Proposed Revision / Corrections: Permit Fee P e $ S'2 e;IC-) 12ev i,NE4 914 ik"'s , peu4.-/A Flow, p 04s/plvekr►, L. cii„v A.,40L54 l /400,44-, 'PA•onue 1 S b Q✓)e-r)./ co)c3 / AOio)o) 1U0(, } A(J1L)1') 1' Additional Increase in Building Value $ Additional S.F. By signing below,I rgg aY\ e-AiA-i- affirm the Revision is inclusive of the proposed changes. (printed name) //S /b Signature of Co, ac or • gen (, ontractor must sign i increase in valuation) Date (Office Use Only) Approved !/ Denied )( Not Applicable to Department Revision/Plan Review Comments «ov OI Q r e 0,3 R- lit S o rk 6-PS+)„ P1-a4S Department Review Required: Buildin• /11 2---- • .shin. & Zoning Reviewed By Tre- •dministra or Public "or _ ,S-- pus s•us is a ety Date Fire Services . V\ CITY OF ATLANTIC BEACH fr, 800 SEMINOLE ROAD ;� ATLANTIC BEACH,FL 32233 I—()%191" OFFICE CO PY (904) 247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 12.18.2017 Permit#: RES17-0300 Site Address: Jax Beach Site Address: 1614 Maritime Oak Dr. Phone: 755.5393,424.9652 Review: 1 Email: bmessina@shdesignjax.com RE#: 169505-1960 Homeowner: Same, jspalten@shdesignjax.com Applicant: SH Design,LLC CORRECTION COMMENTS: These are review comments from 1 of 4 departments reviewing this permit applicati i 1 he energy calculation information submitted is missing the Manu: Compliance Report. 2014 5th Edition of the FBC-Energy Conservat.i n, ' 403.6, R403.6.1. Submit 2 copies. Mike Jones R-e-c. 1. 5-•201 Sr Building Inspector/Plan Reviewer 1-1"-et City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 Fax (904) 247-5845 e/-nc i1-e1 R`PV1 PLi CowN, w"-0n /'S I2- - / F -/'7 C71 1 CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COM NTS Date ) I�0) )3 Revision to Issued Permit Corrections to Comments Permit# CZes(1--O3 Project Address /6/6( 09r)I,vvi-c al a. Contractor/Contact Name SH Qes ii.r, LLL rpt,i4-, Phone 764-4/Zif- ,:16 Sz Email .Z,, '' 6-SS)A) C 04 OPS 1�n j A)1, (L,it., Description of Proposed Revision/Corrections: Permit Fee Due $ 5-e)'OC) Nodded ahr9r)Se.1 4 4 -Ti o hvg9itis 4h ,, u he-p,./0 Additional Increase in Building Value $ CAdditional S.F. ‘1&4 By signing below,I (S?t 44n I t )esSl Np, affirm the Revision is inclusive of the proposed changes. (printed name) / 00//‘ Signature . .C 6 tractor Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved A Denied Not Applicable to Department Revision/Plan Review Comments Depart n�ent Review Required: Buildin /11/�' Planning & Zoning �/ Reviewed By Tree Administrator Public Works Public Utilities / _ /0 '07 0/ Public Safety Date Fire Services CITY OF ATLANTIC BEACH 800 Seminole Road 7, Atlantic Beach, Florida 32233 Jl,,4 2 2 2018 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date )/ ZZ// 8 Revision to Issued Permit Corrections to Comments7-Permit# Res )? - D 3 o3 Project Address Poly nif9r,IiW-P C)4 �f iqt 32Z33 Contractor/Contact Name S/# De-SO r) L(_-(, r J�(L I�✓� Phone 70q-4/24/—9652 Email Irvess) q-cj-Joeso✓j .0c,"`-1 Description of Proposed Revision /Corrections: Permit Fee Du; $ ,SC',DO CJPr°4-i S zun n M r-A1 lS / J d Id Cn A0.1401,4] bei%-i, c/11J- ZtI " Additional Increase in Building Value $ 1/4S: Additional S.F. By signing below,I I '_ ( i- \ .SSS '1 n affirm the Revision is inclusive of the proposed changes. (printed name) )J2Zj/ 6 Signat e o'Co tracto •gen . or must sign if increase in valuation) Date (Office Use Only) Approved )( Denied Not Applicable to Department Revision/Plan Review Comments 6ON7ac7 lU rich- 4.19 Te G cy7 q fay •P-ee, Department Review Required: tanning &Zonin Ur Reviewed By Tree Administrator Public Works Public Utilities 2 ' 1 do l Public Safety Date Fire Services rs.:L�� ,r1 City of Atlantic Beach APPLICATION NUMBER JS " )\ Building Department (To be assigned by the Building Department.) JN. 800 Seminole Road 'CM c __ 0300 ,w r Atlantic Beach, Florida 32233-5445 t�J Phone(904)247 5826 Fax(904)247-5845 UP -=!01119!' E-mail: building-dept@coab.us Date routed: I ( I City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1V)1 4 Mk A rile_ Oa .--Df. De artment review required _Yes No � d g Applicant: -•\- uil0 LSI) I) L L_ annin &Zoning—Th Tree Administrator Project: -Q..--J s'ii\t— (ri t`kA l ONk bc wUoities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [ !Approved. rill<ied. I INot applicable (Circle one.) Comments: BUILDING �Je( 60 PLANNING &ZONING Reviewed by:. --- ...______ Date: 12- I y I TREE ADMIN. Second Review: A roved as revised. Denied. ❑ pp � I Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES X CZ 74 GVer ny PUBLIC SAFETY Reviewed by:_____ Date: (—I - It FIRE SERVICES Third Review: 71Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by:G Date: i—1)— I f{ Revised 05/19/2017 r,.t' 'J``- ..4 ZONING REVIEW COMMENTS City of Atlantic Beach ;, Community Development Department js 800 Seminole Road Atlantic Beach,Florida ptECoPY 4J;31r Date: 12/14/2017 Permit: RES 17-0300 Applicant: SH Design LLC Review: ZONING Address: 830 3rd Street#101,Jacksonville Beach FL Site Address: 1614 MARITIME Phone: 904-755-5393 OAK DR RE#: 169505 1960 Email: bmessina@shdesignjax.com Correction Comments Side Yard Projections: Section 24-83(b) limits side yard projections into side yard setbacks, including roof overhangs, to 24". Please show that this requirement is being met or revise plans accordingly. ge/41"/ °"4419 j 44i Informational Comments ')(je•t.,V &417`'.‘i 2)1( C C t Citrt C4 s ) Brian Broedell Planner { *'rt ; CITY OF ATLANTIC BEACH .i JAS - 3 2018 F 800 Seminole Road ..�_ to Atlantic Beach,Florida 32233 fe '1 ''L_, , 1 ! REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS / e65 Date SIS/ 1 6 Revision to Issued Permit Corrections to Comments Permit# 1 7 - 0 3 00 Project Address / 0 Y Mac f. 1 t t"'C V. /c Dc' Contractor/ Contact Name C!/ 1'7eS j✓ti L-I-c 42i 09✓1 I ' e,s-SI 4 Phone qc y— l2y ?43-z_ Email C:.S.SZN9 'e S it 0 tsii en 15y, Gc. , Description of Proposed Revision / Corrections: Permit Fee Due $ F:Ct)i3E44 Q14 �9l��s / �eit--®A F1oi, 9045/ P '_1 4. O- �' A- flc S 1 n lJ' l Aonivi\ "mK)r1lA(� i /-' Qii€r .1 c4Ic3 / F oO)h1O� ) /--)ciui`) Additional Increase in Building Value $ Additional S.F. By signing below,I_•Pg/e \ e.S'.1/Aaffirm the Revision is inclusive of the proposed changes. (printed name) - ddi /Mb /b Signature of Co. ac or • gen (‘ ontractor must sign i increase in valuation) Date (Office Use Only) Approved Denied 7" Not Applicable to Department Revision/Plan Review Comments ,g. '-c-3-- 0-Ver/7 pc., Department Review Required: Buildin• ' .....-r____' .mini & Zoning s Reviewed By Tre- Administra or Public t►o s .67- i_ / r"--/?v 'us is a ety Date Fire Services CITY OF ATLANTIC BEACH (61 ' ',01', 800 Seminole Road oAtlantic Beach,Florida 32233 r up Jt . i 2 2018 Q .� ''o; )' REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date )/zip 8 Revision to Issued Permit Corrections to Comments 7-Permit# Res 1-7 - 73303 Project Address / JLf nI' - C)ai a i 32Z 3 3 Contractor/Contact Name SN-- c S n LLL r g4(..9"." Phone 70Lf-WY-745- Email •Zfl SSM9 q.CIJdeS/y2J Ay i c c,- t-7 • Description of Proposed Revision/Corrections: Permit Fee Due $ C/ni C- j 70 0/n� Gu M c _ei if 1/1 VVi d Cr, god �,.L,e7 C41#7/74.1 heI %-li c/1,1-Ar- Zit " 0141. Additional Increase in Building Value $ Additional S.F. By signing below,I 1 '_ i I \ Pl\ ,SJR n affirm the Revision is inclusive of the proposed changes. (printed name) ))?* 6 Signat e o'Co tracto •gen . or must sign if increase in valuation) Date (Office Use Only) Approved / Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: :ui / 00 ----irkl 'fanning & Zoning Reviewed By Tree Administrator Public Works f _ 2_ _ ( Public Utilities O Public Safety Date Fire Services CA1.1; JCity of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road p r1� __ �aO� yr Atlantic Beach, Florida 32233-5445 { .)` OS OO(904)247-5826 • Fax(904)247-5EC 0 7 2017 ;;1ys E-mail: building-dept@coab.us Date routed: I I IV l '1 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: i 1 q MAI("t011,e. Oa.IX'. Department review required Yes No uil�di g� Applicant: 0 L.J11 LLL {Panning &Zoning Tree Administrator Project: '\-12-A-3 S'ir\ k t— (rit`y VOrnZ. P blic Works lic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Di pproved. nied. ❑Not applicable (Circle one.) Comments: BUILDING , PLANNING & ZONING Reviewed b : Date: /02--/, 17 TREE ADMIN. Second Review: -4A roved as revised. Denied. pp ❑ ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed • • „, i( Date: /..--,--/7 FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 0--ACITY OF ATLANTIC BEACH ,i �,�' DEPARTMENT OF PUBLIC WORKS J� ,,�i 1200 Sandpiper Lane • J Atlantic Beach,FL 32233-4318 +- 0 TELEPHONE:(904)247-5834 t) .:!: FAX:(904)247-5843 www.coab.us �'� iilvr CONTRACTOR: DATE: 12-13-17 SH Design, LLC PERMIT#RES 17-0300 830 3l Street South#101 ADDRESS: 1614 Maritime Oak Drive Jacksonville Beach, FL 32246 Atlantic Beach, FL 32233 Email: bmessina(c)shdesignjax.com PERMIT APPLICATION FOR NEW HOME Your permit application has been denied by the Public Works Department for the reasons listed below. Please submit this information at your earliest convenience in order for us to approve your application. If you have any questions, please contact Scott Williams, Public Works Director at 904-247-5834 or email swilliams(q),coab.us. PUBLIC WORKS CORRECTION ITEMS: (Submit the following information to the Public Works Department) • Provide impervious surface calculations for entire lot (existing and post construction). • A Revocable Encroachment Permit must be obtained if using pavers in driveway. ✓'--. • Provide what type of material is being used in driveway. (-Pruf*iL • Floor plan measurements are not accurate; provide accurate measurements. tr'-- / • Concrete sidewalk must continue through driveway at correct slope (2%or less). t7 PUBLIC WORKS CONDITIONS OF APPROVAL: (The following comments will be printed on your permit as Conditions of Approval) • Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (247-5814) to request an inspection from Public Works for Erosion and Sediment Control Inspection prior to start of construction. • All runoff must remain on-site during construction. • Roll off container company must be on City approved list (Advanced Disposal, Realco Recycling, Shapell's Inc., Republic Services, Donovan Dumpsters). Container cannot be placed on City right-of-way. • Full right-of-way restoration, including sod, is required. • All runoff must remain on-site. Cannot raise lot elevation. • Maximum driveway width within the City right-of-way is 20'. • A Revocable Encroachment Permit must be obtained if using pavers in driveway. • Concrete sidewalk must continue through driveway at correct slope (2% or less). cc: Toni Gindlesperger, Building Department Jennifer Johnston, Building Department i ;! 1 CITY OF ATLANTIC BEACH A ;a JAN - 3 2018 :14 800 Seminole Road t;7., :,y L'-'-'' ll Atlantic Beach,Florida 32233 41"Itiff, r_.. JAN 0 4 201 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS 26S Date V/��� 5 Revision to Issued Permit Corrections to Comments Permit# I - 0 100 Project Address / 6 /Y (4p,r l T /V"'C 0.0k pc. Contractor/ Contact Name Cil Oesij h Z-L-C, l 2/?9 /e-5s/i"' Phone goy— tag 965 - Email 6 / Lsszc esli Ot--S/ 9o,j10X, C(.4- Description of Proposed Revision/ Corrections: Permit Fee Due $ k PC)1.44 91.4 0 Arlit� fieut-,al t"! o. 'v s/else.)�.n_, .0 a„s'��s J A.0),;\ 111.o'ttoe I S 1u Q ? - c.,o/(.s / AOU)vl, NOC ) ACA(9I`) Xf.vulc :iq.d,,? . p .",-,-) { Additional Increase in Building Value$ Additional S.F. (c .. By signing below,I g ' 05eN e i A--i' affirm the Revision is inclusive of the proposed changes. (printed name) 4111 41111.- Signature .f Co- ac / gor • gen ontractor must sign i increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Dei artment Review Required: -1. 74-!(Z f Buildin /Z • (-- nin & Zonings, eviewed By v� Tre- Administra or Public ors 7.11t09'u. is i . '3 Pus is a eT Date Fire Services yL'Jf City of Atlantic Beach APPLICATION NUMBER 1--- _ � Building Department (To be assigned by the Building Department.) ;73 - 800 Seminole Road .>,-`„ v i'' Q _ `'3�� �� Atlantic Beach, Florida 32233 5445 2017 N ,St� D Phone(904)247-5826 Fax(904) 247-5845 �^ I �"��;� gr Email: building dept@coab.us Date routed: la l l0 l I� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1lDl 4 Mk -tin L 044- f• De artment review required Yes No uiidrng Applicant: 0�J i p LLL cPnl ing &Zoning-13 in Tree Administrator Project: �-e..- s'00.." 6._01.`� VoneksL Public Works illiMMIllo Public Safety Fire Services Review fee $ b Dept Signature w-\ Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPL TION STATUS Reviewing Department First Review: Approved. ❑Denied. of applicable (Circle one.) Comments: BUILDING PLANNING &ZONINGReviewed by: X.A<-4Date: I 2_/;/I 7 TREE ADMIN. Second Review: Approved as revised. ❑Denied. ['Not applicable ØW OR S Comments: BLI ILITIES / Z- $- i7 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 vu!_ '�'' City of Atlantic Beach N PUBLIC UTILITIES DEPARTMENT - '� 1200 Sandpiper Lane ~ Atlantic Beach, FL 32233 1. (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date ( Z - S- 17 Project Address /(a / q V" IA2,(T( lM L CA- - ,--- Number Number of Units ( Commercial Residential ✓ Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) 3�� New Irrigation Meter Upgrade Existing Meter from to (size) 3 7 New Reclaim Water Meter Size /LI New Connection to City Sewer vim, Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application# ?trS I-7 — O 300 i, Water System Development Charge $ 1 . 1 40, 0 0 Sewer System Development Charge $`If CSO , CIO Water Meter Only $ (aS oä Reclaim Meter Only $ (8 S. O(� Water Meter Tap $ Sewer Tap $ Cross Connection $ SO, (0 Other $ TOTAL $ S (T/ 0 e U) (Notes) APPROVED Kayle Moore, P.E. )(_ Date 'rd , ( Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED -i ' C. r .i r� ii'�ili ��� + � P, lE� id . / L . . \titil :i ii CITY OF ATLANTIC BEACH styJAN — 3 2018 800 Seminole Road J s' Atlantic Beach,Florida 32233 \ r) "!os3» - JAN U4 2V3 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date //S / 6 Revision to Issued Permit Corrections to CommentsPermit# - 6 3 00 Project Address 1 b /V qr( 1 (V'C £9. k Dc' Contractor/ Contact Name cm I')F'S J h Z-1.-C 7j2I I9/ !eS`Sp"4 Phone qc y- lag 763-Z- Email 6 M LIE.SSZ7c" Q S/1 Ot3I j)9X, C Description of Proposed Revision / Corrections: Permit Fee Due $ r!OJh E4 914 Ofiks / Ae:iv-at Flo 9045/P.levv-J,..., 0,,,c/A.4r.54 A0016\ -rn io.n kn e i S Qner� c,.01 c.5 I f S oO v NO , ) )(AO I,) 'Revolc.o91,_ .p.4(..ri./0.4.oAt ptr.m_1') . Additional Increase in Building Value $ Additional S.F. By signing below,I "gle i'YN ems/A9- affirm the Revision is inclusive of the proposed changes. (printed name) -- /M b Signature of Co, rac or • gen (, ontractor must sign i increase in valuation) Date (Office Use Only) Approved V Denied Not Applicable to Department Revision/Plan Review Comments KTILl ry e?ltovA- - De'artment Review Required: Buildin• ( / ( ' .•nin -& Zoning Reviewed By Tre- Administra or Public o���l rks� ,��� 1 14" 'u• is a ety /— S---- I V Date Fire Services ..S`�" BuildingPermit Application -.' f E * . pp 11 A "/ FFICE CORY Sem ole Road,ytAttlant c B aach, FL 32233 DEC - 6 2017 i f `ri" ' '-• Phone: (904) 247-5826 Fax: (904) 247-5845 - - - ---_____ Job Address: 1011 1fl 4Imt OAK rt,,( 3 2.25 3 Permit Number: -&Sri— 0300 ----' Legal Description jp+ 10,Atm}Ic 4,6.ha Wit-a. 6?/13Z-139 toto.t p, RE# i 4f:1505- 1 Cf Valuation of Work(Replacement Cost)$ 41001 .( 0O1 000 Heated/Cooled SF Ou�_I Non-Heated/Cooled I CUBO • Class of Work(Circle one):410 ddition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial esidential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No (1 7A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: �.4, Si„S/C 4dMl,L7 / *t, A f.khl.,/ 9 Woo)? Co1eie.- fJ�io ) Z - STOQ.IeS Florida Product Approval# for multiple products use product approval form Property Owner Information e Name: 514 Decay t i_ .C. Address: 830 3`"1 S?. ..S, /OI City Tp 3c,►• State FL Zip 3 2 2. .0 Phone 9'04- ,v SS-S!93 E-Mail JSQAI ne Si+OeSIynjA%.C00% Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Tpshu.A Sea HT" Contractor Information Name of Company: SR SCSI An 13-0 Qualifying Agent: -3-•S1 A.ok SPA11.ln Address $30 3'''. S7: S,Mt' City 7-Ax dc.h State Fr. Zip 3 ZZfa Office Phone %IV- "in'^ 5393 Job Site/Contact Number gat AO QQy—ilZY .. 9411-2 State Certification/Registratio*n# C.6CIZI570/1 E-Mail bmes.Iia ei S# Des/'Iv)A*.. cowv. Architect Name&Phone# UAdi1 Mosby 90y - 610-'1803 Engineer's Name&Phone# A 'eX jecFWt11o,y 1041- 89.I 6200 Workers Compensation Apart c,"g.11dcn.> las Ce. W CV015Slit 0'( en. 11 21/1 A Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. (Signatti of Owner or Agent including Contractor) (Signatur• : ontractor) Signed a Swo to.(or"affirmed)before me this day of Signed an. w.rn t. s a irmed)before me this If day of Ih•�t�q•—-, Zo11 ,by KvIN + • IPLeaia- ,2017 ,by To.)hvA Spwlit" /(Si:•ature of Notary) n tr of ary) :x'40:.0p, Brian Messina 1 .. ,,,,,,c Brian Messina [ Personally Known OR - sig COmmISSI011#G033545E Personally Known OR ,a, _ COmmISSlOn I GG035458 54iC ii, 7 _ F.4 lil .X-Ii [ ]Produced Identification z �-_ ;`` �ires: October 3,2020 [ ]Produced Identification ��., � �o� 3. 2020 Type of Identification: •%.' •;•;. :,,,•, ,, , ,11 , , . ype of Identification: ' "` i '`` Bonded thru Aaron Notary 'milt h, ,, i�,,,,r TREE & VEGETATION AFFIDAVIT �a r S,, City of Atlantic Beach Department of Community Development \�' -0Planning&Zoning Division „r 800 Seminole Road Atlantic Beach,FL 32233 '.1.- .01"119',' (P)904 247-5800 (F)904 247-5845 PERMIT# SECTION I-APPLICANT INFORMATION Q42, ( Owner(s) r Legal Authorized Agent* NAME OF APPLICANT SQ s\,,," I Ir, NAME OF COMPANY Sg0e s l 5n LL L ADDRESS OF COMPANY 8 3O 3 ra S i g_ /()' 7-4X IS(A 3 12 0 PHONE CELL 90y- 5311 EMAIL j re /fi901 SNOC�t„r ,,W. Cc , CONTRACTOR CERTIFICATION NUMBER et L 121 S y 0.7 q J J ATLBCH BUSINESS TAX RECEIPT NUMBER SECTION II-SITE INFORMATION STREET ADDRESS OF PROPERTY M Ai' I-V1 fol-C, p ak Or. Pa)' ci 3 z z. 3 If an address has not been assigned to this property,contact the AB Building Department at(904)247-5826 to request an address. LEGAL DESCRIPTION (A_13S A•4-InAtc gtistA G.,v. uv7N/h�Z 6 f 13Z`I 1 D.A04. (s. .r, LOT l S J BLOCK SUBDIVISION A is C REAL ESTATE NUMBER 1 6q s-b5 i 960 LOT OR PARCEL SIZE: ‘( SQ FT Z 15541 AC RESIDENTIAL X COMMERCIAL OTHER(SPECIFY) 1 affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation"of the Municipal Code of Ordinances for the City of Atlantic Beach,FL and/or I have participated in a pre-application meeting with the Administrator of those regulations. Subsequently,I affirm that no regulated trees and no regulated vegetation will be damaged,destroyed and/or removed from the above-described or adjacent properties in conjunction with this project. SIGNATURE OF OW g SIGNATURE OF OWNER ��� Signec(and sw• . :- ore me on this il day of brumplt , Qp ,by State of _4442.•do Te.5�%...:t SO4,J 4'e--- County of %you Identification verified: Oath sworn: Yes r No lir A� y:�!/,b,� Brian Messina '_ __- ---- - - _ ,a, Commisssion#GG035458 x= Notary Signe ..%� • Expires: October 3, 2020 REIN ,02 Bonded thru Aaron Notary My Commission expires: /0/S/*?c:) OFFICE COPY. • DO NOT WRITE BELOW- OFFICE USE ONLY Applica e Co es:2010 FL O ' DA BUILDING CODE RCIriewResel Approved Disapproved Approved'w/ Conditions Review Initials/Date: 7 00_2s12.pmeut Size Iabitable Space ae s'/ F r, p Non-Habitable !y npervious area • fisceIIaneous Information :,cupancy Group Ge - 3 pe of Construction V 6 tuber of Stories 2 ling District ftp . Occupancy Load Sprinklers Required • d Zone JC Inions/Comments: LA- 113 IACL J ' RIGHT-OF-WAY/EASEMENT PERMIT ff d\ At0;«�"' ! Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address Me(i Ni me OAk Dr. An 3213} Phone ?Ott— 3-Sr- 519 3 Permittee S}4. t)esiyrl 1.14.. Email • split�nQ-SP-Oe,pjr s)L.(cii'N Requesting Permission to Construct 1)'nue woe,woe, A9rve• 4 If i,sfar}i, r L enalt,p9(— Location(Reference to Cross-Street) Tim4ec gt,rli( I' . All 3ZZ33 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of BRIM riNe SSI tow (Project Superintendent) with Company Name Stri O'Siy^ LLC- Phone 10y-1(24f- 165Z • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be nbtif twenty-four(24)hours prior to starting work and again immediately upon completion. Date li/y/l 7• Permittee(signed in presence No I Public) STATE OF FLORIDA IJNT OF D - �,/ • The foregoing instru nt was a. o f ged this ` day of Dec etwittA. ,20 l 4 , by TO uhvob, c44,I4.\ ,who personally appeared before me and (printed name of Permittee) '- acknowledged-that he/she signed the instrument voluntarily for the purpose expressed in it. Personally Known gnat of Notary ' blit,State of Hon.a Produced Identification(Type) Brian Messina E ,a,gUir �i''s Commission/00035458 "d��,fffff,.►i. •"' Expires: October 3, 2020 r • i ,,, Bonded thru Aaron Notary 4+ (1.--:..0..Ant i1 A. ` REVOCABLE ENCROACHMENT PERMIT z REVOCABLE ENCROACHMENT PERMIT by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and Si4 )e.Syn LLC.. of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. This work is generally described as (y Lr U-t. V gr," O f i✓C w'II . Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty (30) days' notice bx CITY to USER,said notice to USER shall be given by certified mail, return receipt requested,to the following address3O 3r4 S7, S , Vo l T11) �C.A( R.. 30250 . • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described property of the CITY, the USER shall replace at the USER's sole expense,any and all material necessarily displaced during the action of maintaining,repairing,operating,replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code,Building Codes,Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of public right-of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. Date 1 2.1 I Lill 3 ow • • • ner/. grinignecl in presence of Notary Public) STAT •F FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this / I r ' day of (( (041---, ,20 1 7 , by —TO h 43..I!c.-"\ ,who personally appeared before me and (printed name of Signer) acknowledged th. :/she signed the instrument voluntarily for the purpose expressed in it. -------444*-- I' Brian Messina 9 / W ' _ ,., Commission#00032020 '4` -,16.74....,41 Expires: October 3, 2020 r " Signaturerf N• . Pu• ii State of Florida ''�ii,9;��`` Bonded thru Aaron Notary / Approved/Public Works Department: Personally Known �V Produced Identification(Type) ! Scott Williams, Public or s Drector Revision. METAL ROOF�.n.�: 01.1.v.PIJHTIED PRI!. ..e u YreM I 1 v�`oQME W4.FARM IF PANTED FASCIA � till DELOUVERED • M��� `( v�o Bo.�,M.E �ILOUVERED DIAMMA MAJ.-.1100.5r 114 Go% O Yauwia'1ID49vmm 94‘ KYR/art Ft 11„..._ I Y .yarn_.suL nem AN II. t.i 1 ,,„, 1 .. ... n _,.._.zi w41enY POMO 4 OP ■ ■ ■ EIL � : T 1— 14 iO - - S ..4.0/ 14/ 4,--- — oo - _ -'-4_ � � PORCH AND TRIM ACCENTS —--`—— R — — _ "••�"` ca o 17 — PP=RACE RR/` U LL Q _ M Pr POPO An TOIO.G —W.pb YD rpl' C 12.Wee 24 4.r RAKE NEADB2 _`II// i "�Lartiw„o..�,,,,, Front Elevation """'�"mom RI.•nem uo Accoar MOP PILL 0 Q 32eia4 R.B.CEDAR 1 i BEV.TOWER LOFT P OUTRIGGERI U Y�&Ta Oro SILL rwn 7ND PL �� -® __1 Pev nas er[ce u✓O OOP APO•CC APR. 9 r�e*.�ROOF P... eawu•u r 1.73 a•PANTED FABOA 2T4 R.B. E _ n� wi VENTED Of..earrTE 1 ,'1 NYOLLAP POPO Y&law NMDRM POP..MPH r G 4.6 R.E.G®AR ,1 m i BEV.BLOCKING {. I''l l,`- _----- _ I-N I �n it O b' B LOUVERED3_ --- T•• m e h 4 VINYL ewTte, I I G WI3 - 4 r s me -- rQ a a I ET, I ■ ■ ■ I m m 4 n p@;;aARDBO1 $B1R111 f '■ 111El F=n A + F__ s'FAeC1A BY-rpm I t 100 IV FL PL BOE eon& I �'b _ sb ri_-♦ } m o ------- k iFrr• P�- : ET FL i A ; {. .. . �� _- I. f*� I ,o n,rw _ __ IFE----- . 1 II \( .., ____ == r .I 1 ,....ms_._ _ M MIMI ---\� uProe, r TOlira, M P -----._ IY .L R. — mP A it";)�PAVBR PATO NICK I r v PYA{D&, IlY1�H1P.ak W MID ROM SHEET I „Lim DLL Rear ElevationvVINAM "" ••'^�•'° • lea PORT RVs ' -._ - _ _. A-3 CAP R mA,m TR,/ -�_ PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH .FLORIDA Project Name:Lot 133 SPEC Home OFFICE COPY Project Address: TBD Maritime Oak Drive AB 32233 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72,please provide the information and product approval number(s)for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: w .floridabuildin• .r•. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A.EXTERIOR DOORS Thermatru Fiberglass Side-Hinged Max DP=+/-67.0 FL 52625 1.Swinging Door Units _ Thermatru Exterior Doors Evaluated for use in locations adhering to the FBC and FL 5262.5 where pressure requirement as determined by ASCE 7 Minimum Design Loads for Buildings and Other Structures does not exceed the design pressure ratings listed on related test report Max DP=+/-47 Jeld-wen Atlantic Vinyl Sliding Per Mfg.Install Inx. FL10976.1 2.Sliding Patio Door 3.Sectional Wayne Dalton Sectional Exterior 16' Max Width x 8' FL 5587.30 Door Assemblies Max Height Design PSF+23/-25 &+25.90/28.80 FL 5587.31 B.WINDOWS 1.Single hung Plygem Plygem 1500 Per Mfg.Install Inx. FL16100.1 FL161002 2.Horizontal slider Plygem Plygem 1500 Per Mfg.Install Inx. FL16102.1 FL 16102.2 5.Fixed Plygem Plygem 1500 Per Mfg.Install Inx. FL16101.1 FL16101.2 Local# Category/Subcategory Manufacturer Product Description Limitation of Use State It C.PANEL WALL — — James Hardie Panel FL13223.2 1.Siding Lap FL13192.2 Shake Panel _ FL13192.4_FL12143 2.Soffits James Hardie D.ROOFING - 2.Underlayment's GAF Materials Underlayment's FL10626.1 3. Metal Roofing Gulf Coast Supply Galvalume FL11651.16 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E.SHUTTERS 3.Storm panels F.STRUCTURAL COMPONENTS 1.Wood Simpson Strong Tie FL 10441 connector/anchor FL 10444 2.Truss plates Mitek Industries Mli 16 ga.Truss Connector plate FL 2197.2 3.Engineered Weyerhaeuser TJI FL1630.1-.6 lumber Rimboard/Microllam LVL/Parallam FL6527.1-.4 PSIJTimberstrand LSL 11.Wall Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# H.NEW EXTERIOR ENVELOPE PRODUCTS 1. James Hardie Bldg. Panel FL13223.2 Products Lap FL13192.2 Shake Panel FL13192.4 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions,along with the list above,on the job site available to the inspector. The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be inspected,they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to include each new product in the categories listed above and will be highlighted to indicate the new products and required information. Authorized Project Agent: Brian Messina , (Contractor or Design Professional) ature) Company Name: SH Design Mailing Address: 830 3rd St.S#101 City: Jacksonville State: FL Zip Code: 32250 Telephone Number: 904.424.9652 Fax Number: PLOT PLAN OF LOT 133, ATLANTIC BEACH COUNTRY CLUB UNIT 2, AS RECORDED IN PLAT BOOK 67, PAGES 132 THROUGH 137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. 41 ill c„� nQ 7 ? 10 _ ` SCALE: 1' = 20' 410 ( , I 1 III 1 1 I LOT 132 I I I m I FOUND E.MILLEIiI IRON - 'Nt O. q' FOUND 1/2'IRON S89'27'S1'E 100.03' (FIELD) I e. M 9.6 PIPE,MILLER 0.5' .' I lO • 9.74 ;1• 11.4 r g. 1 Cy 10.111.,II 0, 0 5'SIDE SETBACK h A C PAD ''iJ 11.0 X:v_ I WATFA- , 9.98 i 9.7 1'=1 73 —�1 £' 0 r 10.3 rl� 24.0 1_ - O N ,j 5.3' I C 1 ,8 ',1. 9 D 11 at �+ o xl vin • B �•)' PROPOSED 2 STORY Y I o � , Imo 0 rn 3 w v S RESIDENCE y o Q; w g y - no g PROPOSED FINISH FLOOR " In 1 I . ..N( 1'i0J .. o l3J N' ElEBATON.13.1 (UAW ea) o 0.4 a0J'o T" �IX9.4 W CV 1.6 •Y 4.0' X11.3 10.0"G ]y5�11 p` N A! �JA O U N(' G ' eoi 3 1 N 0 7 Y t•�l cvN I o 1 �m z n I'7 N 4.0 1 .(71 f'1 . o '1 w r Z Q I I ELECTRIC o Z I ! METER PAST WATER L y 71' a 7.0' n 23.3' _ _1 31.5' 1 ! O 5'SIDE SETBACK 5, J ��PIION� CONCRETE CURB < 12.1 10'010' r„ • 'ISM !GVf1ER r{� 9.9 • X� 1 'r FOUND 2'IRON Ds ',B N89'27 38"W 106. 9' '!o L ",/ c °°a °•-' M� 106.76' (FIELD) , 1RANSFORP� I . 0 1 FOUND 1/2'n10N 1 1 PIPE.MILLER I I LOT 134 I I o I 1 1 I n t I. \ 11 NOTES: \ THIS IS PLOT PLAN. OFFICE CC)PY 2. BEARINGSS BASED ON THE SOUTH LINE OF LOT 133, BEING NORTH 89'27'38" WEST, AS PER PLAT. 3. NO BUILDING RESTRICTION LINE AS PER PLAT. 4. BENCHMARK USED: FOUND MANGNAIL & DISK, LB3672 Approved By Permit Disk EDGE OF PAVEMENT BETWEEN LOTS 13 AND 14, ATLANTIC Building Department BEACH DRIVE. ELEVATION=7.35 (NAVD 88). City of Atlantic Beech,FL THE PROPERTY SHOWN HEREON LIES IN FLOOD ZONE THIS MAP WAS MADE FOR THE BENEFIT OF "X"-SHADED (AREA OF MINIMAL FLOOD HAZARD) AS SH DESIGN, LLC. WELL AS CAN BE DETERMINED FROM THE FLOOD INSURANCE RATE MAP NUMBER 12031C0408H REVISED JUNE 03, 2013 FOR DUVAL COUNTY, FLORIDA KATH I 'WADE, P.S.M. 'NOT BAUD 1RTHOUT THE SIGNATURE AND THE FLORIDA UC. SURVEYOR and MAPPER No. LS 6164 ORIGINAL RAISED SEAL OF A FLORIDA UCENSED VIRBFYOR AND MAPPER.' FLORIDA LIC. SURVEYING & MAPPING BUSINESS No. LB 3672 CHEWNCHECK BY:BY: Y:Y: DAF BOATWRIGHT LAND SURVEYORS, INC. ATE:AUGUST 9, 2017 FILE: 2017-1102 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 SHEETS OF 1 Manual S Compliance Report Job: Atlantic Beach Country... wrightsoft Date: 2017 Entire House B : A/C Designs of St. Augustine Inc. OFFICE COP' ' • Custom 3370 Agricultural Center Dr,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587 License:CAC1813372 Project Information For: SH Designs Fl Cooling Equipment Design Conditions Outdoor design DB: 95.0°F Sensible gain: 33183 Btuh Entering coil DB: 75.8°F Outdoor design WB: 76.0°F Latent gain: 4121 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 37304 Btuh Indoor RH: 50% Estimated airflow: 1350 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman Mfg. Model: GSZ160421B+AVPTC49D14A Actual airflow: 1350 cfm Sensible capacity: 33384 Btuh 101% of load Latent capacity: 5120 Btuh 124% of load Total capacity: 38504 Btuh 103% of load SHR: 87% Heating Equipment Design Conditions Outdoor design DB: 34.0°F Heat loss: 30169 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman Mfg. Model: GSZ160421B+AVPTC49D14A Actual airflow: 1140 cfm Output capacity: 31327 Btuh 104% of load Capacity balance: 27 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1140 cfm Output capacity: 10.0 kW 113% of load Temp. rise: 24 °F Meets all requirements of ACCA Manual S. wri htsoft' 2017-Dec-13 08:58:28 /9liCiA 9 Right-Suite®Universal 2017 17.0.29 RSU01648 Page 1 Design1Atlantic Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: E • 1 1 ' FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Atlantic Beach Country Club Lot 133 Builder Name: SH Designs Street: Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner Jurisdiction: Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (2980.3 sqft.) Insulation Area a. Frame Wood,Exterior R=19.0 2635.00 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 247.50 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=19.0 97.78 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (1864.0,ft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic(Vented) 11-151.9 1303.00 ft2 6. Conditioned floor area above grade(ft2) 2854" b.Knee Wall(Vented) a_12.4- 390.00 ft2 c.other(see details) R= 171.00 ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(523.2 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 207 a. U-Factor: Dbl,U=0.34 ✓ 523.22 ft2 SHGC: SHGC=0.30 kBtu/hr Efficiency U-Factor: N/A ft2 12.Cooling systems a.Central Unit 42.0 SEER:16.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 42.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 3.443 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a.Natural Gas Tankless Cap: 1 gallons 8. Floor Types (2854.0 sqft.) Insulation Area EF:0.960 a.Slab-On-Grade Edge Insulation R=0.0 1380.00 ft2 b. Conservation features b. Floor Over Other Space R=0.0 1159.00 ft2 None c.other(see details) R= 315.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 72.17 PASS Glass/Floor Area: 0.183 Total Baseline Loads: 78.08 I hereby certify that the plans and specifications covered by Review of the plans and :•p4SNE St..0:"••• this calculation are in compliance with the Florida Energy specifications covered by this :' , ... ,:,..%_ i..- ;:. O,t,'•, ' Code. calculation indicates compliance : v %�,, '1••. ;:',,+- .4% s;', with the Florida Energy Code. ���� • ,i..,,. - O cc PREPARED BY: Cristina McAnally Before construction is completed , , ;=-.r - C ac DATE: this building will be inspected for ? c :_ compliance with Section 553.908 . .tea • Q I hereby certify that this building, as desi• - is in compliance Florida Statutes. �'...,,. 1.• `• . g'S::'� with the Florida Energy Code. COD •'' OWNER/AGENT: _ BUILDING OFFICIAL: DATE: / `_ _ �vl� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 12/5/2017 2:58 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM '112405-2014 PROJECT Title: Atlantic Beach Country Club Lo Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2854 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: SH Designs Rotate Angle: 225 Street: Permit Office: Duval Cross Ventilation: County: Duval Jurisdiction: Whole House Fan: City,State,Zip: Atlantic Beach , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Custom CLIMATE VIECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zyne 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT lk/ 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 2854 28540 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor ✓ 1380 13800 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 1474 14740 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation 1st Floor 171 ft 0 1380 ft2 ____ 0.5 0 0.5 2 Floor Over Other Space 2nd Floor ____ ____ 1159 ft2 0 0.5 0 0.5 3 Floor over Garage 2nd Floor ____ ____ 315 ft2 0 0.5 0 0.5 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1597 ft2 0 ft2 Medium 0.75 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 147 N N 12/52017 2:58 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM N405-2014 CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 38 Blown 1303 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 19 Batt 171 ft2 0.11 Wood 3 Knee Wall(Vented) 2nd Floor 19 Batt 390 ft2 0.11 Wood WALLS / Space ace Cavity Width Height Sheathing Framing Solar Belo w V # Omt To Wall Type p R-Value Ft In Ft In Area R-Value Fraction Absor Grade% _ 1 N=>SW Exterior Frame-Wood 1st Floor 19 46 0 10 0 460.0 ft2 0.23 0.6 0 _ 2 E=>NW Exterior Frame-Wood 1st Floor 19 24 4 10 0 243.3 ft2 0.23 0.6 0 3 S=>NE Garage Frame-Wood 1st Floor 13 20 0 9 2 183.3 ft2 0.23 0.01 0 4 E=>NW Garage Frame-Wood 1st Floor 13 7 0 9 2 64.2 ft2 0.23 0.01 0 5 E=>NW Garage Frame-Wood 1st Floor 19 10 8 9 2 97.8 ft2 0.23 0.01 0 _ 6 S=>NE Exterior Frame-Wood 1st Floor 19 6 8 10 0 66.7 ft2 0.23 0.6 0 _ 7 E=>NW Exterior Frame-Wood 1st Floor 19 4 0 10 0 40.0 ft2 0.23 0.6 0 _ 8 S=>NE Exterior Frame-Wood 1st Floor 19 15 4 10 0 153.3 ft2 0.23 0.6 0 _ 9 W=>SE Exterior Frame-Wood 1st Floor 19 45 8 10 0 456.7 ft2 0.23 0.6 0 _10 N=>SW Exterior Frame-Wood 2nd Floor 19 30 6 10 0 305.0 ft2 0.23 0.6 0 _11 E=>NW Exterior Frame-Wood 2nd Floor 19 31 0 10 0 310.0 ft2 0.23 0.6 0 _12 S=>NE Exterior Frame-Wood 2nd Floor 19 20 4 10 0 203.3 ft2 0.23 0.6 0 13 W=>SE Exterior Frame-Wood 2nd Floor 19 39 8 10 0 396.7 ft2 0.23 0.6 0 DOORS v # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>NW Wood 1st Floor None .35 2 8 8 21.3 ft2 2 S=>NE Insulated 1st Floor None .35 2 8 8 21.3 ft2 3 S=>NE Insulated 1st Floor None .35 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.3 72.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 2 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.3 64.0 ft2 14 ft 0 in 10 ft 0 in Drapes/blinds None 3 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.3 26.0 ft2 12 ft 0 in 10 ft 0 in Drapes/blinds None 4 S=>NE 8 Vinyl Low-E Double Yes 0.34 0.3 32.0 ft2 6 ft 0 in 10 ft 0 in Drapes/blinds None 5 W=>SE 9 Vinyl Low-E Double Yes 0.34 0.3 10.7 ft2 1 ft 0 in 10 ft 0 in Drapesblinds None 6 W=>SE 9 Vinyl Low-E Double Yes 0.34 0.3 21.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 7 N=>SW 10 Vinyl Low-E Double Yes 0.34 0.3 48.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 N=>SW 10 Vinyl Low-E Double Yes 0.34 0.3 22.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 E=>NW 11 Vinyl Low-E Double Yes 0.34 0.3 48.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 S=>NE 12 Vinyl Low-E Double Yes 0.34 0.3 28.0 ft2 1 ft 0 in 1 ft 0 in Drapesblinds None 11 S=>NE 12 Vinyl Low-E Double Yes 0.34 0.3 15.6 ft2 1 ft 0 in 1 ft 0 in Drapesblinds None 12 S=>NE 12 Vinyl Low-E Double Yes 0.34 0.3 31.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 13 S=>NE 12 Vinyl Low-E Double Yes 0.34 0.3 16.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 12/5/2017 2:58 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM 8405-2d14 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang V # Out ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 14 W=>SE 13 Vinyl Low-E Double Yes 0.34 0.3 31.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 15 W=>SE 13 Vinyl Low-E Double Yes 0.34 0.3 16.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 16 W=>SE 13 Vinyl Low-E Double Yes 0.34 0.3 24.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 17 W=>SE 13 Vinyl Low-E Double Yes 0.34 0.3 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation —._ v 1 655.92 ft2 655.92 ft2 65.33 ft 9.17 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 3329.7 182.79 343.77 .4216 7 HEATING SYSTEM v # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:9 42 kBtu/hr 1 sys#1 COOLING SYSTEM U # System Type / Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit ✓ None SEER:16 42 kBtu hr 1225 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.96 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS --Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 207 ft2 2nd Floor 26 ft2 Default Leakage 2nd Floor (Default)c(Default)c 1 1 12/5/2017 2:58 PM EnergyGauge F USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM rN405-2014 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [( Jan [[ ]]Feb Mar ]Apr ]May [X]Jun r Jul Xj Aug X Se ]Oct Nov Dec Heating [X�Jan (X]Feb [X]Mar [ ]Apr f ]May I ]Jun Jul ]Aug 4 Sep E ]Oct f XX Nov f X Dec Venting [ Jan [ ]]Feb [X Mar [X]Apr [ ]May [ ]Jun Jul ]Aug [ Sep [X]Oct [X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 0 PM 80 80 78 78 78 78 78 78 78 0 78 78 0 80 78 Cooling(WEH) AM P 78 78 78 78 78 78 78 78 M 788 7 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) PM 66 66 66 66 66 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 68 Heating(WEH) PM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 1-Electric Heat Pump 0% 1 -Central Unit 12/5/2017 2:58 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 • , FOR''M R405'-2014 ENERGY PERFORMANCE LEVEL (EPL) 1.1 DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index, the more efficient the home. , Atlantic Beach , FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 2635.00 ft2 b. Frame-Wood,Adjacent R=13.0 247.50 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=19.0 97.78 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic(Vented) R=38.0 1303.00 ft2 6. Conditioned floor area(ft2) 2854 b. Knee Wall(Vented) R=19.0 390.00 ft2 7. Windows** Description Area c.other(see details) R= 171.00 ft2 a. U-Factor: Dbl,U=0.34 523.22 ft2 11. Ducts R ft2 a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 207 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtuihr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:9.00 Area Weighted Average Overhang Depth: 3.443 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14. Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 1380.00 ft2 a.Natural Gas Cap: 1 gallons EF:0.96 b. Floor Over Other Space R=0.0 1159.00 ft2 c.other(see details) R= 315.00 ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building E S ' Construction through the above energy saving features which will be installed (or exceeded) � 'N.....- gro'••. in this home before final inspection. Otherwise a new EP isplay Card will be completed �ico '' s• .n . based on installed Code complia -.tures. .-1, _ °,;moo. Builder Signature: . Date: 7Licill :v',..__, e_--"" ,A 1 Pill E *' .7. Address of New Home: �*.��1► OA 1Qi , City/FL Zip: � ,,,�-, G �c Vit.- ..../c;../•• 3 ZZ 3 3 c°D. �.. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/5/2017 2:58 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-201 4 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Atlantic Beach , FL, MANDATORY REQUIREMENTS See individual code sections for full details. 0 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law[Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems,if installed at the time of the test,shall be tumed off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm(85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 12/5/2017 2:58 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compl Page 1 of 3 FORM R406-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. • R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 12/5/2017 2:58 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Comp! Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance fumaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with • AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar • energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 12/5/2017 2:58 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compl Page 3 of 3 • FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Atlantic Beach Country Club Lot 133 Builder Name: SH Designs Street: Permit Office: Duval City,State,Zip: Atlantic Beach , FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. r/ Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. ✓ / Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. f� The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air V/ barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/5/2017 2:58 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 -�- Project Summary Job: Atlantic Beach Country... wrightsoft Date: 2017 Entire House By: A/C Designs of St. Augustine Inc. Plan: Custom 3370 Agricultural Center Dr,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587 License:CAC1813372 Pro"ect Information For: SH Designs Fl Notes: Atlantic Beach Country Club Lot 133 Faces East Desi • n Information Weather: Jacksonville Cecil Field NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 °F Outside db 95 °F Inside db 70 °F Inside db 75 °F Design TD 36 °F Design TD 20 °F Daily range M Relative humidity 50 % Moisture difference 40 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29741 Btuh Structure 32992 Btuh Ducts 1507 Btuh Ducts 2240 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Piping 0 Btuh Equipment load 31248 Btuh Use manufacturers data rf Rate/swing multiplier Infiltration Equipment sensible load tuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2881 Btuh Ducts 329 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ftl 2854 2854 Equipment latent load 2 tuh Volume (ft') 28540 28540 Air changes/hour 0.32 0.16 Equipment TotaLLoad Sen+Lat) C2844 _.btuh Equiv. AVF (cfm) 152 76 Req. total capacity at 0. 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN; JANITROL; AMANA DISTI... Trade GOODMAN; JANITROL; AMANA DISTI... Model GSZ160421 B Cond GSZ160421 B AHRI ref 8996207 Coil AVPTC49D14A AHRI ref 8996207 Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 29250 Btuh Heating output 40000 Btuh @ 47°F Latent cooling 9750 Btuh Temperature rise 28 °F Total cooling 39000 Btuh Actual air flow 1300 cfm Actual air flow 1300 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.036 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.92 Capacity balance point = 28 °F Backup: Input= 10 kW, Output = 34121 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. * wrightsoft Ri M-Suite®UnNersal 2017 17.0.29 RSU01648 2017-Dec-05 14:59:35 ACCA 9 Page 1 ..Design Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: E Job: Atlantic Beach Country... -PkwrightsoftProject Summary Date: 2017 Down Stairs By: A/C Designs of St. Augustine Inc. Plan: Custom 3370 Agricultural Center Dr,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587 License:CAC1813372 Pro'ect Information For: SH Designs Fl Notes: Atlantic Beach Country Club Lot 133 Faces East Desi • n Information Weather: Jacksonville Cecil Field NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 "F Outside db 95 "F Inside db 70 'F Inside db 75 °F Design TD 36 "F Design TD 20 "F Daily range M Relative humidity 50 % Moisture difference 40 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18271 Btuh Structure 19195 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18271 Btuh Use manufacturers data Gt) Rate/swing multiplier 1.00 Infiltration Equipment sensible load tuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1121 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling Area (ftl 1380 1380 Equipment latent Inad (11Bturi Volume (ftl 13800 13800 Air changes/hour 0.36 0.18 Equipment Total Load (Sen+Lat) >Btuh Equiv. AVF (cfm) 82 41 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. A.....--_. Wei lhtsoft 2017-Dec-0514:59:35 ACCA9 Right-Suite®Universal 2017 17.0.29 RSU01648 Page 2 ..Design\Atlantic Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: E • Job: Atlantic Beach Country... wrightsoft Project Summary Date: 2017 Up Stairs By: A/C Designs of St. Augustine Inc. Plan: Custom 3370 Agricultural Center Dr,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587 License:CAC1813372 Pro"ect Information For: SH Designs Fl Notes: Atlantic Beach Country Club Lot 133 Faces East Desi • n Information Weather: Jacksonville Cecil Field NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 °F Outside db 95 °F Inside db 70 °F Inside db 75 °F Design TD 36 'F Design TD 20 °F Daily range M Relative humidity 50 % Moisture difference 40 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 11470 Btuh Structure 16555 Btuh Ducts 1507 Btuh Ducts 2421 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12977 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment Sensible Ind tuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1759 Btuh Ducts 329 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling Area (ftl 1474 1474 Equipment latent marl - .OSSA tuh Volume (ft') 14740 14740 Air changes/hour 0.29 0.14 Equipment Total Load (Sen+lat) 5 Btuh Equiv. AVF (cfm) 70 35 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Ri M-Sults Universal 2017 17.0.29 RSU01648 2017-Dec-05 14:59:35 g Page 3 ACCs. ... DesignWtlaMic Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: E • , 4 wrightsoft Right-J® Worksheet Job: Atlantic Beach Country Clu... Date: 2017 Entire House By: A/C Designs of St. Augustine Inc. Plan: Custom 3370 Agricultural Center Dr,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587 License:CAC1813372 1 Room name Entire House Down Stairs 2 Exposed wall 171.0 ft 171.0 ft 3 Room height 10.0 ft 10.0 ft 4 Room dimensions 5 Room area 2854.0 ft2 1380.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 141 I 12E-Osw 0.068 n 2.45 1.52 593 545 1334 830 283 283 693 431 G 2 glazing,clr low-e 0.340 n 12.24 13.03 48 0 588 625 0 0 0 0 12E-Osw 0.068 e 2.45 1.52 423 257 629 391 220 146 357 222 2 glazing, clr low-e 0.340 e 12.24 35.58 124 0 1518 4412 32 0 392 1139 11 (-D 11J0 0.600 e 21.60 18.90 42 42 907 794 42 42 907 794 12E-Osw 0.068 s 2.45 1.52 854 734 1797 1118 457 425 1040 647 tl 1; 2 glazing,clr low-e 0.340 s 12.24 13.03 120 240 1469 1563 32 64 392 417 vr_G12E-Osw 0.068 w 2.45 1.52 765 533 1305 812 460 298 730 454 2 glazing, dr low-e 0.340 w 12.24 35.58 232 0 2840 8254 162 0 1983 5764 PJ 12C-Osw 0.091 - 3.28 1.51 247 226 740 341 247 226 740 341 r-D 11 DO 0.390 e 14.04 12.28 21 21 295 258 21 21 295 258 P 12E-Osw 0.068 - 2.45 0.95 98 98 240 93 98 98 240 93 P 16B-19ad 0.049 - 1.76 2.69 407 407 718 1097 0 0 0 0 C 16B-19ad 0.049 - 1.76 2.69 171 171 302 461 0 0 0 0 C 16B-38ad 0.026 - 0.94 1.43 1303 1303 1220 1863 0 0 0 0 F 20P-19c 0.050 - 1.80 0.75 315 315 567 236 0 0 0 0 F 22A-cpm 1.180 - 42.48 0.00 1380 171 7264 0 1380 171 7264 0 6 c)AED excursion 773 2835 Envelope loss/gain 23731 23923 15033 13395 12 a) Infiltration 6010 1669 3239 900 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 250 4 1000 0 0 Appliances/other 6400 4900 Subtotal(lines 6 to 13) 29741 32992 18271 19195 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 29741 32992 18271 19195 15 Duct loads 5% 7% 1507 2240 0% 0% 0 0 Total room load 31248 35232 18271 19195 Air required(cfm) 1300 1300 760 684 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. &._.01/4 wrightsOft Right-Suite®Universal 2017 17.0.29 RSU01648 2017-Dec-05 14:59:35 age 1 ...Design Atlantic Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: E 4 wrightsoft Right-J® Worksheet Job: Atlantic Beach Country Clu... Entire House Date: 2017 By: A/C Designs of St. Augustine Inc. Plan: Custom 3370 Agricultural Center Dr,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587 License:CAC1813372 1 Room name Up Stairs 2 Exposed wall 0 ft 3 Room height 10.0 ft 4 Room dimensions 5 Room area 1474.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (R) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 14I 12E-Osw 0.068 n 2.45 1.52 310 262 641 399 I G 2 glazing,dr low-e 0.340 n 12.24 13.03 48 0 588 625 12E-Osw 0.068 e 2.45 1.52 203 111 272 169 2 glazing, clr low-e 0.340 e 12.24 35.58 92 0 1126 3273 11 I---D 11.10 0.600 e 21.60 18.90 0 0 0 0 yJ 12E-Osw 0.068 s 2.45 1.52 397 309 756 471 l�-G 2 glazing,dr low-e 0.340 s 12.24 13.03 88 176 1077 1147 ILG12E-Osw 0.068 w 2.45 1.52 305 235 575 358 2 glazing, dr low-e 0.340 w 12.24 35.58 70 0 857 2491 9 12C-Osw 0.091 - 3.28 1.51 0 0 0 0 I D 11D0 0.390 e 14.04 12.28 0 0 0 0 P 12E-Osw 0.068 - 2.45 0.95 0 0 0 0 P 16B-19ad 0.049 - 1.76 2.69 407 407 718 1097 C 16B-19ad 0.049 - 1.76 2.69 171 171 302 461 C 16B-38ad 0.026 - 0.94 1.43 1303 1303 1220 1863 F 20P-19c 0.050 - 1.80 0.75 315 315 567 236 F 22A-cpm 1.180 - 42.48 0.00 0 0 0 0 6 c)AED excursion 695 Envelope loss/gain 8699 13285 12 a) Infiltration 2771 770 b) Room ventilation 0 0 13 Internal gains: Occupants @ 250 4 1000 Appliances/other 1500 Subtotal(lines 6 to 13) 11470 16555 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 11470 16555 15 Duct loads 13% 15% 1507 2421 Total room load 12977 18976 Air required(cfm) 540 676 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Dec-05 1 ACA wrightsoftRight-Suite®Universal 2017 17.0.29 RSU01648 Page 2 ...DesignWtlantic Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: E wriglttsoft Right-J® Worksheet Job: Atlantic Beach Country Clu... Down Stairs Date. 2017 By: A/C Designs of St. Augustine Inc. Plan: Custom 3370 Agricultural Center Dr,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587 License:CAC1813372 1 Room name Down Stairs 1st Floor 2 Exposed wall 171.0 ft 171.0 ft 3 Room height 10.0 ft 10.0 ft heat/cool 4 Room dimensions 1380.0 x 1.0 ft 5 Room area 1380.0 ft' 1380.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F), (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 n 2.45 1.52 283 283 693 431 283 283 693 431 �G 2 glazing,dr low-e 0.340 n 0.00 0.00 0 0 0 0 0 0 0 0 12E-Osw 0.068 e 2.45 1.52 220 146 357 222 220 146 357 222 2 glazing,dr low-e 0.340 e 12.24 35.58 32 0 392 1139 32 0 392 1139 11 I---D 11J0 0.600 a 21.60 18.90 42 42 907 794 42 42 907 794 12E-0sw 0.068 s 2.45 1.52 457 425 1040 647 457 425 1040 647 2 glazing,clr low-e 0.340 s 12.24 13.03 32 64 392 417 32 32 392 417 VLG12E-Osw 0.068 w 2.45 1.52 460 298 730 454 460 298 730 454 2 glazing,dr low-e 0.340 w 12.24 35.58 162 0 1983 5764 162 0 1983 5764 P 12C-Osw 0.091 - 3.28 1.51 247 226 740 341 247 226 740 341 `-D 11D0 0.390 e 14.04 12.28 21 21 295 258 21 21 295 258 P 12E-Osw 0.068 - 2.45 0.95 98 98 240 93 98 98 240 93 P 16B-19ad 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-19ad 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 - 0.00 0.00 0 0 0 0 0 0 0 0 F 20P-19c 0.050 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-cpm 1.180 - 42.48 0.00 1380 171 7264 0 1380 171 7264 0 6 c)AED excursion 2835 2835 Envelope loss/gain 15033 13395 15033 13395 12 a) Infiltration 3239 900 3239 900 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 250 0 0 0 0 Appliances/other 4900 4900 Subtotal(lines 6 to 13) 18271 19195 18271 19195 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18271 19195 18271 19195 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total room load 18271 19195 18271 19195 Air required(cfm) 760 684 760 684 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A&....11/4- C A ws igFttsOft Right-SuiteO Universal 2017 17.0.29 RSU01648 2017-Dec-05 14:59:35 age 3 ...Design\Atlantic Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: E wrightsoft Right-J® Worksheet Job: Atlantic Beach Country Clu... Up Stairs Bate: 2017 By: A/C Designs of St. Augustine Inc. Plan: Custom 3370 Agricultural Center Dr,St.Augustine,FL 32092 Phone:904-829-8898 Fax:904-829-6587 License:CAC1813372 1 Room name Up Stairs 2nd Floor 2 Exposed wall O ft O ft 3 Room height 10.0 ft 10.0 ft heat/cool 4 Room dimensions 1474.0 x 1.0 ft 5 Room area 1474.0 ft' 1474.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IR! 12E-Osw 0.068 n 2.45 1.52 310 262 641 399 310 262 641 399 �G 2 glazing,clr low-e 0.340 n 12.24 13.03 48 0 588 625 48 0 588 625 12E-Osw 0.068 a 2.45 1.52 203 111 272 169 203 111 272 169 2 glazing,clr low-e 0.340 a 12.24 35.58 92 0 1126 3273 92 0 1126 3273 11 (-D 11 JO 0.600 e 0.00 0.00 0 0 0 0 0 0 0 0 12E-Osw 0.068 s 2.45 1.52 397 309 756 471 397 309 756 471 11 G 21 glazing,clr low-e 0.340 s 12.24 13.03 88 176 1077 1147 88 88 1077 1147 IILG12E-Osw 0.068 w 2.45 1.52 305 235 575 358 305 235 575 358 2 glazing,clr low-e 0.340 w 12.24 35.58 70 0 857 2491 70 0 857 2491 P 12C-Osw 0.091 - 0.00 0.00 0 0 0 0 0 0 0 0 11D0 0.390 e 0.00 0.00 0 0 0 0 0 0 0 0 P 12E-Osw 0.068 - 0.00 0.00 0 0 0 0 0 0 0 0 P 16B-19ad 0.049 - 1.76 2.69 407 407 718 1097 407 407 718 1097 C 16B-19ad 0.049 - 1.76 2.69 171 171 302 461 171 171 302 461 C 16B-38ad 0.026 - 0.94 1.43 1303 1303 1220 1863 1303 1303 1220 1863 F 20P-19c 0.050 - 1.80 0.75 315 315 567 236 315 315 567 236 F 22A-cpm 1.180 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 695 695 Envelope loss/gain 8699 13285 8699 13285 12 a) Infiltration 2771 770 2771 770 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 250 4 1000 4 1000 Appliances/other 1500 1500 Subtotal(lines 6 to 13) 11470 16555 11470 16555 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 11470 16555 11470 16555 15 Duct loads 13% 15% 1507 2421 13% 15% 1507 2421 Total room load 12977 18976 12977 18976 Air required(cfm) 540 676 540 676 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. &__1., wrightsoft Right-Suite®Universal 2017 17.0.29 RSU01648 2017-Dec-05 14:59:35 age 4 ...Design'Atlantic Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: E 4 Level 1 105 cfm ,.— 8" e 55 cfm 79 cfm FO 6" 1R 6" Great Room Sup Riser 16" Dining Kitchen /MP • �. 12 " 8" /�1 1216" 03 .6„ 105 cfm 55 cfm '79 cfm 23 cfm p;4 0 4 Stairs 4 ' Pant`y Drop .e 9cfm Bath 30 cfm - 4" 1� 12" , r9 —41m 12" Fo - 65 cfm w Sup Riser 12" 7" ► _ � 120 cfm _ Bed 4 _� 7 Garage f r lai ial 1 Job #: AIC Designs Scale: 1 : 73 Performed for: Page 1 SH Designs 3370 Agric uftural C enter Dr Right-Suite)Universal 2017 Saint A ug ust ine, FL 32092 17.0.29 RSU01648 FL Phone: 904-829-8898 Fax: 904-829-6587 2017-Dec-0513:34:08 ...c Beach Country Ckib Lot 133.rup V level 2 16 cfm M/Wie - 101 cfm /4 FO 7 „ / M/Wic - / Sup Riser 52 cfm 16" Master M/ Bath e 7 16" _ IB@7 „ al 6„ 101 cfri! 54 cfm - 16" El 4cfm r 4cfm 115 cfm 12 " We SII Bath 2OP 17 7 " Bed3 111 10" 4" 4 ---__ Stairs 2 • - Di 63 cfm _ 24 x 18 MIT II 18, 14" lop< 7" ■ ■ 16" 1�18�._,. 10 12 „ 12 ,1 - "" 16" - r�r 10„ 6 ■ ■ F22 1 jil 7 7 " Al 58 cfm 1300 cfm 101 cfm 90 cfm 20 LaundrySup Riser 14 / Bed 2 Loft / 7 " 90 cfm Job #: AIC Designs Scale: 1 : 73 Performed for: Page 2 SH Designs 3370 Agrc ultural C enter Dr Right-Suite®Universal 2017 Saint Augustine, FL 32092 17.0.29 RSU01648 FL Phone: 904-829-8898 Fax: 904-829-6587 2017-Dec-05 13:34:08 ...c Beach Country Club Lot 133.rup 0 0 0 Y a C (O N N N (O In In (O (O Ln Ln Nt Q co (p co h h N N- r- V MM i•i a i. U) N U) U) U) N N N N U) U) N N U) U) U) N U) U) U) U) U) U) U) n 0 u 0 0 E L ,8-$ 000000000000000000000000 0 o La L a La o 0 0 0o 0d 0o ui La toL'i Ln un o i LLn Ln 0 2 c V rrr Nt (0 (0 V � CO (0 NtNI' r r r Cr) M r M M V A-- s- N in J 7 N 0 aRT O0000c) -, 0 m d •c222S = E L4E l) Nrr (OMNt0Ln0) 0 V OOMNMNhhrNN0LU 0 .E .E .E .E .E U Y `.. cr � • ( V OnUI� V (70MOMg NO .- 0N M A N NM0) (0 pJNON000 Q J N N r 0 0 O O r r M O 0 r - j -74 x x x x x x x x x x X x x x x x x x x x x x x x 0 0 2 LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL ‘- N- r > > > > > > > > > > > > > > > > > > > > > > > > o G) C 0 x 0 0 0 0 0 0 0 0 0 0 0 0 0xx Occ 0 0 0 0k 0 0 0xOtt 0 0 N i 0 0 0 0 0 0 0 0 0 ox 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 RS 0CA CV CV CV 0 00000 ,� 000000000000000000000000 E c = = = = r E G) E E vv � r� � (o (ovQ3000O (0 (b (or; r� cov � L� r� vcov W �- �0 w .E .E .E .E .E U 0 _� :� a = N 0 N 0 0 0 A N N N - 00 0 0 0000000000000000000000 °D c $ = o 000rct 000000000000000000000000 00 +r 06 .N LL 000000000000000000000000 LL Wff, r 0 LL E r Cl °DO o W m 0 A NtNtrL0LAU) LU - COI') LO1� 00 � MNr0Ln (0 ri a cn /L� /— .� LT E N O r (C) U) Ln r Al' (0 (O M CO Al' 0) 0) Ln r LO 0 0 (O n LL Li r r r r 515 7g2 NA t+ +7 c c � 0N0) N0 (O (OMLnlnln0) 0) LULULU0 (OOLnLna) MN 2 2 0` 0 C g co O) Ln N Nt N (O 0 O h l- 'Al Ln Ln co r (0 (O Ln c n T0- ._ .N OI E r r r O /7 = n N y o +r L p 9 2J , (, U. (nI N r c0 1"--- 0 COI- NN (O co co O) 0) corr00) L000 VOD CO t O ZaO oO CO h aO r r (O 0 CO (O 0) 0) 0) CO CO 0 (O Ln V r- N 0) rn V c n C co vhctMM (00) 00 (V N (OrrMNtNNtNtNLn R' Q W Q U) LTL N N CO r r r M M N N r N N r r N N r o of N .Ti) +3+ }� U 6 - v� Q 0 O. W 0 0 u E LL 0) N m N � t U o U .c U o .c _c . ct c o o U c o o os U o ++ m 0 Ln U) m _c t (A 0 2Q) L6 0) 6 M '� o QU) Q@ N N 7 .. g T. O U 01 U U U) y 7 O O > N rn ;4 o — .- -.6 .7..- . E < m C • 7 S < 0 ce ce c t Z' L u Q N !!!��� . 4-_ a :35E U) L6 Q N N N = L N V a c c n m% t L t c a m 3. ii iii r _2 ')� o +. N O O- 0 . m z . m d m .c c Q o d m r = m 0 o m m •0 m u I X > 7 0 U CO CO CO CO m 0 0 0 LL U U Y le -IJ J 2 2 2 2 2 a N 'S M WdQU) JQI- Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 469 309 0.100 336 16.0 0 x 0 VinIFIx st1 st6 Peak AVF 238 156 0.100 223 14.0 0 x 0 VinIFIx st1 st1 Peak AVF 707 465 0.100 400 18.0 0 x 0 VinIFIx st2 Peak AVF 193 271 0.100 345 12.0 0 x 0 VinIFIx st7 Peak AVF 176 269 0.100 343 12.0 0 x 0 VinIFIx st3 st3 Peak AVF 400 564 0.100 404 16.0 0 x 0 VinIFIx st5 Peak AVF 302 235 0.100 384 12.0 0 x 0 VinIFIx st4 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 1300 1300 0 0 0 0 Ox 0 VIFx t WPI f1t50ft 2017-Dec-0513:34:00 9 Right-Suite®Universal 2017 17.0.29 RSU01648 Page 2 ...Designs\Atlantic Beach Country Club Lot 133.rup Calc=MJ8 Front Door faces: