Loading...
1505 Selva Marina Dr - Permit RES017-0036 OFFICE COPD CITY OF ATLANTIC BEACH ri 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date 4.18.2018 Revision to Issued Permit V Corrections to Comments Permit# R C SO 17- 0 0 3 Project Address 1505 Selva Marina Dr Atlantic Beach, FL 32233 Contractor/Contact Name Alesch Contracting -Ted Alesch Phone (904) 613-6517 Email ted@aleschcontracting.com Description of Proposed Revision/Corrections: Permit Fee D $ 5-0.Oa Add front door replacement per attached shop drawings Add open trellis detail /rafter tail extensions at front of house Revise fence height to 6' per approved Variance Request Additional Increase in Building Value $ 10,000.00 Additional S.F. N/A By signing below,I Ted W Alesch affirm the Revision is inclusive of the proposed changes. 11and (printed name) 4.18.2018 Signature o on actor/ (Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Rev* Comments fia/1. IF Fon, /I'-,- S�r vPy '�o t/p r; �� 12vo-f exTph SiUr oirwC-e t5•uv4- q0, /tz Department Review Required: u1 df in nning& Zoning Reviewed By Tree Administrator Public Works Public Utilities o/ Public Safety Date Fire Services CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 f (904) 247-5800 SUBMITTAL COMPLETENESS REVIEW COMMENTS Date: 4/25/2018 Permit#: RES017-0036 Site Address: 1505 SELVA MARINA DR Review Status: APPROVED RE#: 171935 0000 Applicant: ALESCH CONTRACTING INC Property Owner: NALL WILLIAM Email: ted@aleschcontracting.com Email: Phone: 9046136517 Phone: THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: FRONT DOOR, RAFTER TAILS, FENCE HEIGHT 1. Submit a site plan that shows the roof extension and gives the distance to the 40ft. B.R.L.from the edge of roof extension. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 904.247.5844 Email:mjones@coab.us Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: Gaglione/Nall Permit # QCSy i 7—Gb3G Project Address: 1505 Selva Marina Dr As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide roduct approval may be obtained at:www.floridabuildin .or . Category/Subcategory 11anufacturer Product Description Limitation of Use State# Local # A.EXTERIOR DOORS 1. Swinging Masonite Double Door Unit ith Sidelights FL 22521.1 2. Sliding 3. Sectional 4. Roll up 5. Automatic 6. Other l B.WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8.Projected 9.Mullion 10. Wind breaker 11.Dual action 12. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments 3. Roofing fasteners 4.Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other .7 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local# E. SHUTTERS 1. Accordion 2.Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor 2. Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight r 2. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# H.NEW EXTERIOR i ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and convect to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) (Signature). Company Name: Alesch Contracting, Inc Za,&W Mailing Address:_1946 Beachside Ct _ City: Atlantic Beach State: FL Zip Code: 32233 Telephone Number: ( ) 904-613-6517 Fax Number: Cell Phone Number: ( ) E-mail Address:ted@aleschcontracting.com OFFICE COPY Open Rafter Tail Extension Detail Gaglione Residence 1505 Selva Marina Dr Atlantic Beach, FL 32233 PLAN VIEW Existing roofExisting roof line to remain.� /line to remain. Note: All fasteners to be 316 Marine Grade Stainless. SECTION VIEW 12 4 Existing Roofing Material not to be disturbed New 2x6x8'Rafter tail extensions.Attach to existing Existing 2x6 / open on top and Rafters to remain. / bottom.Extends approx 36" 16"layout. f beyond existing fascia. Existing W Space approx 6'apart. soffit plywood Existing 2x Existing Framed Walls 2x8 Fascia to (2)2x6 installed remain.Notch plumb between rafter New 2x8 Fascia around new 2x6 tails. Spacing to be rafter tail. equal. ©2018 Alesch Contracting, Inc April 18, 2018 CGC1516238