Loading...
664 Beach Ave - Revision dwgsTYPICAL STAIR DETAIL N.T.S. SCREW 5/4x6 TO FLOOR J❑IS WITH S08250E� P. T. SECTION B N.T.S. 1 8,_o#_ NEW ADDITION F❑UNDATI❑N PLAN N.T.S. 2x10 BAND BOARD I 12 5 1/2 (2) SDWC15600 PER CONNECTION BETWEEN EXISTING NEW 2x6's EXIST, TRUSS @24" ❑ C 12 3 EXIST CONNECT NEW CEILING J❑IST TO EXISTING TRUSS WITH (2)10d NAILS NEW CLASS A FIBERGLASS SHINGLES OVER NEW 30 LB, FELT OR TYPE 2 UNDERLAYMENT EQUIVALENT OVER NEW 7/16" ❑ S B NAILED 6" ❑ C, ON ALL SUPPORTS W/ 8d RINK -SHANK NAILS 1 NEW 2x6's #2 SYP, @24" ❑ C, NEW 2x4's #2 SYP @24" ❑ C SIMPS❑N 2,5A- (3) 2 x 6 / s 5A- (3)2x6's (2)2x6's W/ 2-1/2" PLYWOOD EXIST, OVERHANG TO BE CUT OFF (2) MTS12Z FOR BEAM TO COL, C❑NNECTI❑N SCREW 5/4x6 P T TO FLOOR J❑IST WITH S08250FWP DECKING BY SIMPS❑N 6-SO8300FWP SCREWS BY SIMPS❑N (5) 2x10's @24" ❑ C P T JOISTS --SCREW 2x8's P T LEDGER BOARD W/ (2) SDWS2230ODBRC12 T❑ EVERY STUD 12 15 1/2 2x6's SP6 @48" ❑,C, 1211-71(TOP t TO BEAM) (2) 1/2110 BOLTS FOR TOP & BOT, COL, -2x10 P T BAND BOARD 1) 2x10's P T _DEA SIDE OF COL, NEW 6X6 P,T, COL TYPICAL STAIR DETAIL N.T.S. SCREW 5/4x6 TO FLOOR J= WITH S08250F� P. T. SECTION(B N.T.S. 1 NEW ADDITION 110110111 /- (2)2x8' 2)2x8's 6x6 RT, 2XB'S P. T. @24" D.C. W/ 5/4x6 RT, DECK 20" SQ x 12" W/ (2)#5x1'-2" E,W, ra r J co F❑UNDATI❑N PLAN N,T.S, 1 12 5 1/2 C❑NNECTI❑N NOTES: (2) SDWC15600 PER CONNECTI❑N BETWEEN EXISTING NEW 2x6's EXIST, TRUSS @24" ❑.0 12 EXIST, CONNECT NEW CEILING JDIST TO EXISTING TRUSS WITH (2)10d NAILS --_ EXIST BLDG TO REMAIN— ALL CONNECTORS SHALL BE PERIODICALLY INSPECTED AS PART OF ROUTINE MAINTENANCE, STAINLESS STEEL CONNECTORS AND FASTENERS ARE USED, NEW CLASS A FIBERGLASS SHINGLES OVER NEW 30 LB FELT OR TYPE 2 UNDERLAYMENT EQUIVALENT OVER NEW 7/16" ❑,S,B, NAILED 6" ❑ C ON ALL SUPPORTS 3 W/ 8d RINK -SHANK NAILS 1 NEW 2x6's #2 SYP @24" Of, NEW 2x4's #2 SYP @24" O C, SIMPSON 2,5A- (3) 2 x 6 / s 5A- (3)2x6's (2)2x6's W/ 2-1/2" PLYW❑❑D EXIST, OVERHANG TO BE CUT OFF (2) MTS12Z FOR BEAM TO COL, CONNECTI❑N SCREW 5/4x6 P,T, TO FLOOR J❑IST WITH S08250FWP I11K"k it l BY SIMPS❑N 6-S08300FWP SCREWS BY SIMPS❑N 2 5 1/ 2 (5) 2x10's P,T, JOISTS @24" [1, C. SCREW 2x8's P,T, LEDGER BOARD W/ (2) SDWS2230ODBRC12 TO EVERY STUD SECTION A N,T,S, 1 8/-2// NEW 4// CONCRETE SLABS WITH 6x6 - W1,4xW1 4 W W,F, ON 6 MILD VAPOR BARRIER ON 95% TREATED COMPACTED S❑IL 'da d v J ° a a' a 2'-0" SQ d C d a A104/17/18 REV PER BLDG OFFICIAL COMMENT & CONTRACTOR'S REQUEST STRUCTURAL DESIGN FOR RESIDENCE ADDITION/ALTERATION @664 BEACH AVE ATLANTIC BEACH, FL SCALE; AS NOTED APPROVED BY; DRAWN BY;PSL DATE; 12/08/17 REV, 04/18/18 PAUL LI ENGINEERING GROUP, LLC (CA#32056) Ph. (904)737-6876 EMAIL: PAULLIENG®BELLSOUTH.NET 8160 W, BAYMEADOWS WAY, SUITE 145 DRAWING NUMBER JACKSONVILLE, FL 32256 1 170927-1 2x6's SP6 @48" ❑ C 12 (TOP t TO BEAM) CROSS SECTION "1-1" 3/4"=1'-0" (2) 1/2110 BOLTS FOR TOP & DOT, COL, -2x10 P,T, BAND BOARD (1) 2x10's P,T @EA SIDE OF COL, - NEW 6X6 P,T, C❑L,,--' 10" ABA66Z REVISION BP# PFS/ s- - 0 1a3 DATE 1 /oll. 12-01,1 SIGNED,i m�' R 0 N T L E I N I G H T L E V A T 1 0 N WORK LIST GENERAL NOTES 1. CONSTRUCT NEW COVER DECK AS SHOWN ON THE PLAN 1, DESIGN LIVE LOADS 2. REPLACE THE WHOLE ROOFING TO MATCH THE NEW ADDITION ROOF 20 P.s,F FLOOR 40 P,S,F COVERING DECK ROOFING PUBLIC ROOMS 100 P,S,F 3. FASTEN TOP & BOTTOM CHORDS TOGETHER USING 2 -ROWS OF CORRIDORS 80 P,S,F SDWC 15600 BY SIMPS❑N AT 6 ❑.C. STAGGERED 2, FLORIDA BUILDING CODE 5TH ED - EXISTING BUILDING - ALT LEVEL 1 4. FASTEN 2X45 MEMBERS TOGETHER WITH ONE ROW OF THIS BUILDING IS NOT LOCATED IN THE WIND BORNE DEBRIS REGION SDWC 15600 BY SIMPSON AT 4" O.C. BASIC WIND SPEED 130 MPH WIND IMPORTANCE FACTOR 1 RISK CATEGORY TYPE II WIND EXPOSURE C COMPONENTS/CLADDING PRESSURE (P,S.F,) N/A INTERNAL PRESSURE COEFFICIENT OPEN 1.0 PARTIALLY ENCLOSED N/A 1%, IA j irl!l 111-1 111 ENCLOSED 0.18 3, MATERIALS ROOFING: ROOF UNDERLAYMENT ASTM D226 TYPE I OR TYPE II, ASTM D4869 TYPE I OR TYPE II, OR ASTM D6757 ROOF FLASHING (DRIP, RAKE, CAP, VALLEY) 26 GAUGE ROOF SHINGLES ASTM D225 OR D3462 RATED FOR THE WINDSPEED ABOVE ASTM E108 CLASS -A FIRE RESISTANCE RATING SHINGLE NAILING (4 NAILS PER SHINGLE) PER MANUFACTURER'S SPECIFICATIONS CONCRETE f'c = 3,000 PSI REINFORCED BARS ASTM A615, A305, GRADE 60 STRUCTURAL TIMBER - PINE SOUTHERN PINE, GRADE MARKED N❑.2 ® ® MEDIUM GRAIN, SURFACED DRY, MOISTURE CONTENT 19% Max, TIMBER C❑NNECTIONS� AS SHOWN ON PLAN OR EQUAL TO SIMPSON CO, "STRONG TIE" CONNECTIONS OFFICE COPY OR EQUAL, USE MANUFACTURER'S RECOMMENDED GALV, NAILS, 4. F❑❑TING DEPTHS SHOWN REPRESENT THE MINIMUM DEPTH TO WHICH FOOTINGS SHALL BE CARRIED, FOOTINGS SHALL BE LOWERED AS REQUIRED TO OBTAIN SUITABLE BEARING, ALL UNSUITABLE FOUNDATION MATERIAL SHALL BE REMOVED WITH FOOTINGS RESTING ON UNDISTURBED SOIL WITH A MINIMUM BEARING a REVIS CAPACITY OF 2,500 P,S,F, UNLESS OTHERWISE SHOWN OR INDICATED. y' Zcl 11 IT 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, ETC, NECESSARY I JIT FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTI❑NS OF THE -IJI I- Jl I IT, [Al 1 11 11 111 11 1 STRUCTURE TO THE EXISTING STRUCTURE, THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS NECESSARY FOR PROPER FABRICATI❑N AND ERECTI❑N OF ALL STRUCTURAL MEMBERS. 6, BEFORE PROCEEDING WITH ANY WORK WITHIN OR ADJACENT TO THE EXISTING STRUCTURAL DESIGN FOR STRUCTURE, THE CONTRACTOR SHALL BECOME FAMILIAR WITH EXISTING RESIDENCE ADDITION/ALTERATION CONDITI❑NS. DURING THE PROCESS OF C❑NSTRUCTI❑N, IT SHALL BE THE @664 BEACH AVE ATLANTIC BEACH, FL E L V A T CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE WHERE THE EXISTING STRUCTURE IS TO BE MODIFIED TO ACCOMMODATE SCALE; AS NOTED APPROVED BY: DRAWN BYl PSL NEW CONSTRUCTI❑N AND TO PROTECT FROM DAMAGE THOSE PORTIONS OF THE DATE; 12/08/17 REV, 04/18/18 EXISTING STRUCTURE WHICH ARE TO REMAIN. PAUL LI ENGINEERING GROUP, LLC (CA#32056) f n/ Ph. (904)737-6876 EMAIL: PAULLIENG®BELLSOUTH.NET 1� 8160 W, BAYMEAD❑WS WAY, SUITE 145 DRAWING NUMBER JACKSONVILLE, FL 32256 1 170927-2 HAKIM RESIDENCE ACTUAL EXISTING BUILDING SETBACK I 1876 BEACH AVENUEN 59'-6 1/4" REAR SETBACK _ E -2'-8 314" -- — ---------------- � - - I PER CODE — — — -- _ ATI AKITIr FZI=Arw Pi npinA- SILT FENCE I r------- - I PROPERTY LINE ' � I n N 0 US Navy Commissary 0 Navy Exchange m - k P y NORTH PROJECT LOCATION i 1676 Beach Avenue SHEET LIST SHEET NUMBER SHEET NAME A 100 TITLE SHEET A 101 GENERAL NOTES A 102 GENERAL NOTES A 103 FLASHING DETAILS A 104 FLASHING DETAILS A 200 DEMO PLANS A 201 FIRST FLOOR PLAN A 202 SECOND FLOOR PLAN A 203 THIRD FLOOR PLAN A 204 FINAL PLANS A 205 ROOF PLAN A 206 SCHEDULES A 300 ELEVATIONS A 301 ELEVATIONS A 400 SECTIONS A 401 SECTIONS A 402 SECTIONS A 403 SECTION DETAILS A 404 SECTION DETAILS E 200 FIRST FLOOR RCP - ELECTRICAL E 201 SECOND FLOOR RCP - ELECTRICAL E 202 THIRD FLOOR RCP - ELECTRICAL Total: 22 40 Ilk W NORTH 0 2' 4' 8' SCALE: 1/4" = V-0" I I; I I' Al I I I I � N I co 0 I 2 I;IkSIN400 I I• I I' I 2 A 300 — _ ------ --------- -- II I 2 ' A 401 {� I I• I II I' i II I I � I ' I EAVE EDGE � I N 63-9 1/2" G 7(1'_Q 1/91, SIDE SETBACK LINE PER CODE I� PROPERTY LINE ISSUED FOR PERMIT AND CONSTRUCTION 02.21.2018 APPLICABLE CODES: • 2010 FLORIDA ACCESSIBILITY CODE, FBC CHAPTER 11 • FLORIDA BUILDING CODE - BUILDING 2014 EDITION • FLORIDA BUILDING CODE - RESIDENTIAL 2014 EDITION • FLORIDA BUILDING CODE - PLUMBING 2014 EDITION • FLORIDA BUILDING CODE - FUEL GAS 2014 EDITION • FLORIDA BUILDING CODE - MECHANICAL 2014 EDITION • NATIONAL ELECTRICAL CODE - 2011 EDITION • NFPA 101 LIFE SAFETY CODE - WITH FLORIDA MODIFICATIONS 2010 EDITION • FLORIDA FIRE PREVENTION CODE - 2014 EDITION • W/ 2009 NFPA 101 LIFE SAFETY CODE COMPLIANCE METHODS: WORK AREA COMPLIANCE METHOD (FBC 101.5.2) THE BUILDING OR PORTION THERE OF SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE OR ENERGY EFFICIENT THAN ITS EXISTING CONDITION. (FBC 601.2) ACCESSORY OCCUPANCY: SINGLE FAMILY RESIDENTIAL DWELLING. 2 I. I1 I I BUILDING OCCUPANCY CLASSIFICATION: A 301 I; I I ; I I ACTUAL EXISTING ' v � I 10,-0,, BUILDING SETBACK RG -M A 400 ; I I FIRE RATING SEPARATION: II I ; I 1 HOUR BETWEEN GROUP R-1 AND A OGGUPANCIES (FBC I I 1 I 1 TABLE 508.4) 1 i I i i i A 300 —CHIMNEY MEANS OF EGRESS: A 401 Ly I IAK' ' I ; I NUMBER OF EXISTINGS REQUIRED: 2 EXITS FOR OCCUPANT SKYLIGHT LOAD GREATER THAN 49 (FBC TABLE 1015.1) IMPORTANT: *ALL BEDROOMS IN THIS RESIDENCE MEET OR EXCEED THE l EMERGENCY ESCAPE AND FIRE RESCUE REQUIREMENTS BY ACTUAL EXISTING I HAVING AT LEAST ONE WINDOW OPENING PER ROOM OF 5.7 7'-6" ' ' SQUARE FEET AND MEET THE SILL REQUIREMENTS OF LESS BUILDING SETBACK fig --SSB EXISTING CONCRETE THAN 44" ABOVE FINISHED FLOOR. REFER TO WINDOW TAGS TO BE REMOVED AND CORRESPONDING ROUGH OPENING IN WINDOW SIDE SETBACK _ , I I � . I SCHEDULE. LINE PER CODE ' I 2 I A 404 I i i I TO THE BEST OF MARK MACCO, ARCHITECTS KNOWLEDGE, THE INFORMATION AND BELIEF, THAT THE PATH OF EGRESS TRAVEL WITHIN THE ALTERED TENANT SPACE IS IN COMPLIANCE WITH THE FLORIDA ACCESSIBILITY CODE, I ; I CHAPTER 11 OF THE FLORIDA BUILDING CODE 2010. ' I *NO UNDERGROUND OR OVERHEAD UTILITIES PROPERTY LINE IN VICINITY OF PROPOSED WORK. I — '-- - - - - - - - - - - - - - - - - -- — — — I I I *A FOUNDATION SURVEY SHALL BE PERFORMED _ -`1 w I AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTORS PRIOR TO A 301 o I I SILT FENCE FRAMING INSPECTION OR, ALL PROPERTY MINIMUM I i l MARKERS SHALL BE EXPOSED AND A STRING (� I BUILDING STRETCHED FROM MARKER TO MARKER TO VERIFY 1 j EXISTING CONCRETE SETBACK LINE REQUIRED SETBACKS. NO UNDERGROUND OR TO BE REMOVED PER CODE OVERHEAD UTILITIES IN VICINITY OF PROPOSED SILT FENCE I I i I ACTUAL EXISTING WORK. No -- - --------J I BUILDING SETBACK ' CL I n' `------------ cn ------------ BUILDING CALCULATIONS: I o o I i_ — - — — — — — — — — — — — — — — — — — — — I U I I I i t LOT TOTAL: 7,363 SF LLJ TEMPORARY I I I (PERMEABLE PAVERS)I I 1ST FL. AC SPACE: 1,208 SF C ) TOILET LOCATION ' I I (TEMPORARY I I I I 2ND FL. AC SPACE: 1,50$ SF DUMPSTER I I 3RD FL. AC SPACE: 1 073 SF LL LOCATION) I I ------- N -36'-4" TOTAL AC SPACE: 31789 SF ____ ___ _ _ ----- — — E71'-81/4" L — _ -------- -- — — — I 1ST FL. COVERED DECK AREA 322 SF I i ----------------------- ----- - - - _— _ _ --------- - --- - I 2ND FL. FRONT DECK AREA 371 SF L — — _ zi�— - N -40'-7" L ----- - -- --I-- — I 2ND FL. REAR DECK AREA 56 SF PROPERTY LINE DRIVEWAY I SILT FENCE 3RD FL. DECK AREA 517 SF E -1'-9 3/4" I EW BUILDING I SETBACK SILT FENCE I BUILDING SITE FOOT PRINT: 2,018 SF I =RONT SETBACK I TOTAL SITE COVERAGE: 3,669 SF 2 SITE P LAN I INE PER CODE I TOTAL LOT PERCENT COVERAGE: 60% A 300 3/16" = V-0" I MARK MACCC ARCHITECTS ORWARD DESIGN. UNPARALLELED EXECUTION, 472 OSCEOLA AVENUE JACKSONVILLE BEACH, FL 32250 E: Info@MaccoArchitects.com PH: 904.249 -ARCH (2724) www.MaccoArchitecfs.com OF 94- FG6 MARK W. MACCO 7;p1 AR96004 •cs�j, G�� BRED P� r MARK MACCO, AIA NCARB FLORIDA REGISTRATION: # AR96004 TENNESSEE REGISTRATION: # 105588 No. Description Date 1 REVISION 3 02/21/18 MAR 0 2 2018 HAKIM RESIDENCE TITLE SHEET Project Number ##### Date FEBRUARY 21, 2018 Drawn By MWM Checked By MWM A 100 Scale As indicated c N 0 c� 00 T- o N N 04