Loading...
1 Aherne - Permit ROOF18-0044 CITY OF ATLANTIC BEACH 4 800 SEMINOLE ROAD v~ ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF18-0044 Description: re-roof of lifeguard station Estimated Value: 9000 Issue Date: 4/27/2018 Expiration Date: 10/24/2018 PROPERTY ADDRESS: Address: 1 AHERN ST RE Number: PROPERTY OWNER: Name: CITY OF ATLANTIC BEACH Address: 800 SEMINOLE RD ATLANTIC BEACH, FL 32233-5444 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: E B MORRIS GENERAL CONTRACTORS INC Address: 238 Canal Boulevard Suite 1 PONTE VEDRA BEACH, FL 32082 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. City of Atlantic Beach APPLICATION NUMBER JS f, Building Department (To be assigned by the Building Department.) f � 800 Seminole Road �r Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 i I p 1 E-mail: building-dept@coab.us Date routed: l `0 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l A wi_{ Rs A- De ent review required Yes No Building Applicant: 4Vkfg_ Cen�'� cS Planning oning Tree Administrator Project: _ ( O ���� GvC� Public Works Public Utilities Safi �r� Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: roved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING ��(( PLANNING & ZONING Reviewed by:_� Date: -44 2 TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application Updated 12/8/17 City of Atlantic Beach APR 1 2 2018 >; 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 Job Address: 1 Ahern Street,Atlantic Beach,FL 32233 Permit Number: �_Do Legal Description RE# Valuation of Work(Replacement Cost)$ 9,000.00 Heated/Cooled SF 275 Non-Heated/Cooled 137 • Class of Work(Circle one): New Addition Alteratio Re air Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): mmer� Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes (19� N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Re-Roof Florida Product Approval# See Product Approval Form attached for multiple products use product approval form Property Owner Information 800 Seminole Road Name: City of Atlantic Beach Address: City Atlantic Beach State FL Zip 32233 Phone E-Mail swilliams@coab.us Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: E.B.Morris General Contractors, Inc. Qualifying Agent: Address 238 Canal Blvd,Suite 1 CityPonte Vedra Beach State FL Zip 32082 Office Phone 904-998-9281 Job Site/Contact Number 904-237-9252 State Certification/Registration# CGC57425;CCC57213 E-Mail ebm@ebmorrisgc.com Architect Name& Phone# Ebert Norman Brady Architects 904-241-9997 Engineer's Name&Phone# Atlantic Engineering Services 904-743-4633(Structural) Simes&Rosch,LLC 904-260-3031 (MEP) Workers Compensation Southern Owners Insurance Company 1/1/2019 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR �ftORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Signatu e o e gent) (SignZoractor) (incluing ntractor) Jorn to(oraffi be re t isl day of Si ned and sworn to(or aore me this(ZI day of 'nip, by LOI A.DER LIS N is F (Signature tary s •oig GR191. Jul 4,J2018GER OFf� Commission#FF 1141 TONT GINDLE ' � Personally Known OR F 924951 ;:'� Y&'' My COMMISSIO [ ersonally Known [ ] Produced Identification :: EXPtAEg,October 8,2019 [ ] Produced Identification Type of Identification: PubncUnderon>e' Type of Identification: PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA Project Name: City of Atlantic Beach Lifeguard Tower Renovation Permit # CnF 1 [4[� 6o 54/ Project Address' 1 Ahern Street,Atlantic Beach,FL 32233 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide roduct approval may be obtained at:www.floridabuildin .or . Category/Subcategory Manufacturer Product Description Limitation of Use State# I.ocal # A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4.Roll up 5.Automatic 6. Other B.WINDOWS 1. Single hung 2.Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7.Pass-through 8.Projected 9.Mullion 10.Wind breaker 11.Dual action 12. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments Boral sea] Undedayment FL12619 3. Roofing fasteners 4.Nonstructural metal roof Petersen Edgelock FL23953 3 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12.Roofing slate _ 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other �.._ Category/Subcategory Manufacturer Product Description Limitation of Use State 4 Local# E. SHUTTERS I. Accordion 2.Bahama 3. Storm panels 4. Colonial 5. Roll-up 6.Equipment 7. Other F.STRUCTURAL COMPONENTS 1. Wood connector/anchor 2. Truss plates 3.Engineered lumber 4.Railing 5.Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9.Plastics 10.Deck-roof 11. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight i 2. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# H. NEW EXTERIOR c j ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. Eric Moms . (Contractor Name) (Print Name) e) Company Name: E.B.Morris General Contractors, Inc. Mailing Address: 238 Canal Blvd,suite 1 Ponte Vedra Beach City: State: FIL Zip Code: 32082 Telephone Number: (soa ) 998-9281 Fax Number:( 904 ) 998-9584 237-9252 ebm@ebmorrisgc.com Cell Phone Number: ( soa ) E-mail Address: PAC FEB PETERSEN ALUMINUM CORPORATION FL 23953 METAL ROOFING CATEGORY INSTALLATION DETAIL BINDER ;/n TABLE OF CONTENTS: CO Snap-On Standing Seam Panel 24GA Steel & .032" Aluminum............. 2-3 Snap-Clad Panel 16oz/sf Copper........................................................................... 4-6 Tite-Loc Plus: .040" Aluminum x 12" & .040" Aluminum x 16......................... 7-14 M-36 Panel (36"wide): 24GA Steel & .032" Aluminum.....................................15-16 R-36 Panel (36" wide): 22GA, 24GA, .032" & .040" Aluminum....................... 17-18 7.2" Rib Panel: 24GA & 0.032" Aluminum.......................................................... 19-21 2.67" x 7/8" Corrugated Panel: 24GA & .032" Aluminum.................................22-24 Tite-Loc Plus: 12" x .040 Aluminum over 22GA Steel Deck............................. 25-26 Tite-Loc Plus: 12" x 22GA Steel over 22GA Steel Deck..................................... 27-28 Tite-Loc Plus: 18" x 24GA Steel over 22GA Steel Deck.................................... 29-30 Tite-Loc Plus: 16" x .032" Aluminum over 15/32"Pl ood..............................31-32 Ed e-Loc 1.0: .032" Aluminum............................................................................ 33-37 Large Precision Tile: 14.5" x .032" Aluminum.................................................. 38-40 Large Precision Tile: 14.5" x 24GA...................................................................... 38-40 Precision Diamond Tile: 7.25" x .032" Aluminum............................................41-43 Precision Diamond Tile: 7.25 x 24GA Steel.................................41:.43.. ,,"'nniI►►,,, , Locke Bowden,P.E. 4 FL Reg.#49704 D • # ; = 7�• STgT .a •'. .� E OE �:4 F •.�ORIDP •� k.�, sc�aJsS •,� A L E Page 1 of 43 FL 23953 Edge-Loc 1.0 .032" Aluminum Page 33 of 43 ch u€C o TEST 129 1/2" FIXTURE 4 0 J --- ------------------------- 5 -- II =wo II II BZW II II W<w � II II � II II a II w II � j N w 5 II 1� II II N � II W II i II II II II � a jl II � 4 II II w 0 II O w II II � o II II i � ---- ---- --_-_- � z --------------- 24 --------- ----24 2x12 /2 SOUTHERN YELLOW PINE TEST Tom, DECK 4 N o �m a TEST DECK ELEVATION T.s. ..-lk —'" geetterbgeftr. Test sample complies with these details Deviations arc noted $ Reportr. E1977.01-450-18 Date 03/10/2015 Verified 14%Also Role 0+ • W (FORMER FL 17810) s 52 3/4" 76 3/4' 6 n ANCHORAGE AND ATTACHMENT NOTES: I�f PLYWOOD SHEATHING TO STRUCTURAL SUPPORT FRAME. ____ _—__ — --- CORNER AND FIELD SPECIMENS: � TT , rF 8D x 2-1/4" GALVANIZED RING SHANK COMMON NAILS AT 6" O.C. 4q§1 tll II II II II III III II II it II III III I I i t I I I III 1/2" PLYWOOD FELT PAPER. g a III II II II II SHEATHING PERIMETER AND SEAMS; 0.120' x 1 1/4' GALVANIZED ANNULAR RING SHANK ROOFING III I I I I I I I III NAILS WITH 32ga. TIN CAPS SPACED 6' O.C. uq w III I I I I I I III INTERMEDIATE ROWS; 0.120" x 1 1/4" GALVANIZED ANNULAR RING SHANK ROOFING Ego III I I I I I I I Ili NAILS WITH 32ga. TIN CAPS SPACED 12" O.C. STAGGERED 2 III I I {I i l A 4' OVERLAP WAS USED WHEN LAYING ADJACENT SHEETS OF FELT PAPER. a ill II II II II 111 VAPOR AND MOISTURE BARRIER. `�! li l I I l l if I III I A SINGLE LAYER OF HT PRO QUIK—STICK MEMBRANE WAS SELF ADHERED TO THE III II it I! �LLI FELT PAPER. A 4' OVERLAP WAS USED BETWEEN ADJACENT SHEETS. III II II I I f�I 1 10 III I I I I O 1 r nl r-T FIRE BARRIER. ! III II II II II �I I EACH SHEET OF VERSASHIELD WAS CUT TO THE REOUIRED SIZE AND LAID LOOSELY III I( I I e II Immo-`p .I I OVER THE QUIK—STICK HT MEMBRANE. A 5" OVERLAP WAS USED WHEN LAYING 4" III I I I I 12" i t i ADJACENT SHEETS OF VERSASHIELD. i OVERLAP III II II it III IIT-T=m:mwT.TI l Li I II II I � III I II II I a III R � fl o fl � I III II II II I III II o II o o II o I a. III II II II v o III II TIN CAPS II II I ——— VERSASHIELD J U- " 2 II -fi nuj W WITH ►- FELT PAPER HT PRO QUIK STICK ROOF NAILS Z 3 Z J Q J SHEATHING SYSTEM ELEVATION "'T'sN 0 W av) B ul Bette rTogether. Tcgt sample cumpiw; ,uh chase dttails Deviations are noted Fi �L,Report+ E1977.01r150-IB Datc 03/10/2015 Vcrdicd By Alan Rda Page 35 of 43 (FORMER FL 17810) n FIELD SPECIMEN M 0.032" ALUMINUM PANELS = 20" COIL WIDTH 16' COVERAGE ON 1/2" PLYWOOD /10 x 1-1/2" PANCAKE TYP. 0.032" HEAD SCREWS 12" FROM ENDS ALUMINUM PANEL AND 16" ON CENTER OCL 120" / CL n ----------- j _ I PANEL I SEAM HTRPRO OUIK—STICK Z j Lnv I 30/ FELT PAPER a o m I I � 1/2' PLYWOOD SHEATHING S Z i 16" i TYP. FIELD INSTALLATION N.T.S. a I /10 X 1-1/2" PANCAKE HEAD SCREW p / 3" FROM EACH PANEL END ONLY I I I \ TYP. 0.032" y / ALUMINUM PANEL La WO � I — I _ --- � VERSASHIELD ¢ J --- --- -- - 7 HT PRO OUIK-STICK N a 16" 30/ FELT PAPER o z PERIMETER COVERAGE \ w PANEL FASTENERS /10 X 1-1/2" PANCAKE 1/2" PLYWOOD . a SHEATHING HEAD SCREWS AT 3" O.C. G r:�,:.I ,c:BetterTogether. PANEL END DETAIL PANEL ELEVATION N.T.S NAS nev,ahomate,wtrtl g FIELD SPECIMEN Repun ti E1977.01.450-16 Uat.03/10/2015 Venlied By Alan Xule rn w Page 36 of 43 (FORMER FL 17810) p 0.032" ALUMINUM PANELS CORNER SPECIMEN �n 20" COIL WIDTH 16" COVERAGE ON 1/2" PLYWOOD X10 x 1-1/2" PANCAKE � TYP. 0.032' HEAD SCREWS 6" FROM ENDS ALUMINUM PANEL aT AND 6" ON CENTER / a 120" c { v v m -------------- ------------- o PANE ELD SEAM L - HTPROIQUB(-STICK c� \ 30# FELT PAPER � 0'r° I \ 1/2" PLYWOOD I SHEATHING I l 6' TYP. CORNER INSTALLATION N.T.S. Z ` ° I I I I I ' #10 X 1-1/2" PANCAKE HEAD SCREW O / ;" FROM EACH PANEL END ONLY z I I / \ TYP. 0.032" a. ALUMINUM PANEL W O I I j u I I z = z I -- VERSASHIELD < :1 - ---- --- ----- — ---- HT PRO OU1K-STICK N 16" \ 30# FELT PAPER p w PERIMETER COVERAGE PANEL FASTENERS 1/2" PLYWOOD #10 X 1-1/2" PANCAKE \ SHEATHING A' a HEAD SCREWS AT 3' O.C. \ / IrI,.�.,:,BetterTogetber. • PANEL ELEVATION N.T.S. PANEL END DETAIL N.T.S. Text sam{DcvaNnns ire1nute IFC(1C{:n 15 Ou Itepnr{n E1977.01-450.18 G �' CORNER SPECIMEN [ )-.ire 03r Nr7813 V¢nlied Rv Alan Rule � rn w Page 37 of 43 BORAL ROOFING : • ' Build something great T11 II _ 3 it > �'`4� ,��•;�.�� yam. � y Y� j4 & WEATHER SAVE EASY UNCOVERED HIGHGRIP HIGH UNDERALL YEAR RESISTANT TIME MONEY INSTALLATION EXPOSURE NO SLIP TEMPERATURE ROOFING LIMITED MATERIALS WARRANTY • Self-adhered water proofing for fast and easy installation • Up to 10 tiles per stack when roof loading • High strength woven polyester surface remains intact • UV resistant for up to 6 months under high foot traffic • 30 year limited warranty • Stable in low and high temperatures for all climates • Self-seals around fasteners • Suitable for use under all roofing materials www.bor • Boral TileSealTM HT ' l 11 k. 4 , a ,q r Is a x A�' � z "."""` Aft ell HIGH PERFORMANCE FOR ANY ROOF IN ANY CLIMATE Durable Protection-All Season Easy Installation Protects against wind,rain,,snow and ice-dams by Eliminates use of so many nails by self-adhering WEATHERANT bonding to the base sheet or directly to the roof deck NSTEUAASY ON directly to the deck or to a base sheet.Reduces the RESISand self-sealing around every fastener penetration. installation time.Great surface traction provides safer, faster and easier installation for the entire roof. ImmuSave Time and Money The flexibility and robustness of the materials l Many ways to save when compared to hot mopping: allow Boral TreSeal"'to be installed in freezing ,,,r A a„E, faster coverage with less people,no kettles to buy or or hot summer temperatures to get the job done maintain&safer than hot mopping. without delays. 216 square foot per roll-more than competing underlayments. 6 months Uncovered Exposure 1WCan be left uncovered and exposed to the elements w�" for up to 6 months without degradation. �I POP- 14 All P� O DID YOU KNOW... Superior Grip ® Boral TileSeal"is rated up to 260°F. Wet or dry,Boral TileSeal"has a superior slip-resistant Excellent under metal roo@ng. wexew surface making it a favorite among roofers.Strong , rM W sur polyester surface provides excellent adhesion strength for foam installations. "I have used other self-adhered tile underlayments and Boral TrleSeal far exceeds them in warranty and ease of installation. Unequalled Product Performance Thanks Boral fora great product with a great warranty." 30 year limited warranty for guaranteed performance ,,, under any roo�g material.Boral TileSeal"meets Craig Squier,President,Kirkey Roofing,Inc. wAauxrr Englewood,FL or exceeds all national,Florida 8 Miami-Dade building code requirements and outperforms all other underlayments. "Bora/TileSeal is our self adhering membrane of choice.It delivers UNDERAU ROOFM beyond our expectations compared to other competitive products MATSINS in the market for not only Tile Roofs,but our Metal and Shingle applications as well," Scoff Tillett,Kenny's Roofing,Inc. www.boralna.com CERTIFICATIONS/APPROVALS SPECIFICATIONS Miami-Dade County NOA 11-0714.04 Roll size Tx 72' Florida Building Code FL12619 Roll weight 67.5 lbs ICC ESR-1783 Coverage 2 squares ASTM D4869,D226,Type I and Type II Thickness 60 mil D1970,E2178 Rolls per pallet 20 rolls Patent US 6,296,912 B1 Pallet weight 1350 lbs PART NUMBERS 91020 2 Square Roll 91589 Drop Ship/Ship To-360 Rolls/Truck 91059 Drop Ship/Ship To-720 Rolls/Truck 91860 Drop Ship/Ship To-20 Rolls/Pallet Mixed Truck adv, ABOUT BORAL ROOFING Boral Roofing is a subsidiary of Boral USA,the country's largest premium provider of complete roofing and re-roofing solutions for architects as well as commercial • residential builders. Boral Roofing operates 15 clay and concrete tileria manufacturing plants throughout the US and Mexico. 'k ABOUTBORAL USA Headquartered in Roswell,Georgia, Boral USA through its subsidiaries employs approximately 1,500 individuals at more than 140 operating and distribution sites across the United States.The U.S.operations include the country's largest brick manufacturer • the largestand concrete roof Corporate Office Western Office Customer Service Boral Roofing Boral Roofing 800 669 TILE(8453) 200 Mansell Court East,Suite 310 7575 Irvine Center Drive,Ste.#100 Roswell,GA 30076 Irvine,CA 92618 Sales Offices Phoenix,ARIZONA Rialto,CALIFORNIA Kapolei, HAWAII Corona,CALIFORNIA Denver, COLORADO Kansas City, MISSOURI Gilroy,CALIFORNIA Pompano Beach, FLORIDA Henderson, NEVADA Lathrop,CALIFORNIA Lake Wales, FLORIDA Katy,TEXAS 0 Stockton,CALIFORNIA Atlanta, GEORGIA Tacoma,WASHINGTON �> z www.boraina.com F © Download a 4R Code reader app ti ! for your smartphone,then take a r 'I photo to V!Sil Our webslt6. O CI ,-�i ® The Boral Logo is a trademark Committee For .7 of Boral umaed or its agiates TILE ROOFING j`iireWe DWe llg8 and may be registered in many I N S T I T U T E •. •*=oA.A i jurisdictions worldwide. owl CR, C p, �M.•. Ilr�iirrlie EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 Tp� �y 353 CHRISTIAN STREET, UNIT #13 N1 1 1 ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Boral Roofing /MonierLifetile Evaluation Report M35710.12.10-R2 7575 Irvine Center Drive FL14317-R1 Suite 100 Date of Issuance: 12/21/2010 Irvine, CA. 92618 Revision 2: 06/24/2011 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2007 Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Cs.61�o_S41'!S �� The facsimile seal appearing was authorized s-,-S OF; ."4u F by Robert Nieminen,P.E.on 06/24/2011 0 ..k, This does not serve as an electronically signed Nv 65�..:.. document. Signed,sealed hardcoples have been Robert ).M. Nieminen, P.E. �rp`a�E',.`` transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 '�'"""""" to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityi ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Boral Roof Underlayments, as produced by Boral Roofing / MonierLifetile, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, Physical Properties ASTM D226 1997 1507.5.3, 1507.7.3, T1507.8, 1507.8.3, 1507.9.3, 1507.9.4 1507.3.3 Physical Properties ASTM D2626 2004 1507.2.4, 1507.2.9.2, Physical Properties ASTM D1970 2001 1507.3.9, 1507.5.6, 1507.8.7, 1507.9.8 1523.6.5.2.1 Physical Properties TAS 103 1995 1507.3.3 Installation Practice FRSA/TRI 07320 2005 3. REFERENCES: Entity Examination Reference Date ERD (TST 6049) Physical Properties M33180.08.10 10/09/2010 PRI (TST 5878) Physical Properties NEI-006-02-01 04/01/2002 PRI (TST 5878) Physical Properties NEI-034-02-02 03/23/2006 PRI (TST 5878) Physical Properties NEI-045-02-01 08/08/2007 PRI (TST 5878) Physical Properties NEI-053-02-01 05/01/2008 PRI (TST 5878) Physical Properties NEI-070-02-01 08/12/2009 PRI (TST 5878) Physical Properties NEI-031-02-02:REV 10.27.10 10/27/2010 PRI (TST 5878) Physical Properties NEI-029-02-01REV: 11.03.10 12/03/2010 PRI (TST 5878) Physical Properties NEI-046-02-OIREV 12/17/2010 UL(QUA 1743) Quality Assurance Service Confirmation Exp. 12/20/2013 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering Underlayments: 4.1.1 Boral TileSeaIT" 50"T is a nominal 50-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment. 4.1.2 Soral TileSealTm "T is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment. 4.1.3 GatorSealTM is a nominal 55-mil thick, granular-surfaced, fiberglass reinforced, self-adhering SBS modified bitumen roof underlayment. 4.1.4 StormSentryTM is a nominal 120-mil thick, mineral-surfaced, fiberglass reinforced, self- adhering SBS modified bitumen roof underlayment. 4.1.5 CitadelTM is a nominal 42-mil thick, smooth-surfaced, fiberglass reinforced, self-adhering SBS modified bitumen roofing underlayment for use as a base-layer in two-ply underlayment systems. Exterior Research and Design, LLC. Evaluation Report M35710.12.10-R2 Certificate of Authorization#9503 FL14317-R1 Revision 2: 06/24/2011 Page 2 of 9 C)o TRINITY ERD 4.2 Mechanically Fastened Underlayments: 4.2.1 AlcazarT" is a nominal 30-mil thick, smooth-surfaced, fiberglass reinforced, SBS modified bitumen roofing underlayment with self-adhering side laps; meets physical requirements of ASTM D226, Type II, ASTM D2626 and ASTM D4601, Type II. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop Boral Roof Underlayments are follows. Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof covers. Refer to the installation instructions and Table 2 for two-ply underlayment options. Table 1: Roof Cover Options Asphalt Wood Underlayment Shingles Nail-On Tile Foam-On Tile Metal Shakes& Slate Shingles Alcazar Yes Yes No No Yes Yes Boral TileSeal 50"T Yes No No Yes Yes Yes Boral TileSeal"T Yes Yes (See 554.1)YeYes Yes Yes GatorSeal Yes No No No Yes Yes StormSentry Yes Yes No No Yes Yes 5.4.1 "Foam-On Tile" is limited to use of Polyfoam PolyPro AH160 unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. 5.5 Allowable substrates are noted below: 5.5.1 Direct-Bond to Deck: ➢ Citadel, Boral TileSeal 50"T, Boral TileSeal"T, StormSentry or GatorSeal self-adhered to: plywood or ASTM D41 primed plywood. 5.5.2 FRSA/TRI 07320 does not address wind uplift resistance of direct-deck, adhered underlayment systems beneath foam-on tile systems, where the bonded underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck, adhered Boral underlayment systems. 5.5.2.1 Maximum Design Pressure = -45 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AH]. Primer: (Optional) ASTM D41 Base Layer: (Optional) Citadel, self-adhered Underlayment: Boral TileSeal"T, self-adhered Exterior Research and Design, LLC. Evaluation Report M35710.12.10-R2 Certificate of Authorization#9503 FL14317-R1 Revision 2: 06/24/2011 Page 3 of 9 TRINITYERa 5.5.3 Bond to Base Layer Underlayment: ➢ Boral TileSeal 50"T, Boral TileSeal"T or GatorSeal self-adhered to: ASTM D226, Type II felt, Alcazar or Citadel. ➢ StormSentry self-adhered to: ASTM D226, Type II felt For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.5.4 Bond to Other Substrate Types: ➢ Citadel, Boral TileSeal 50"T, Boral TileSealHT, StormSentry or GatorSeal self-adhered to: ASTM D41 primed metal (e.g., flashing metal, valley metal, etc). 5.6 Exposure Limitations: 5.6.1 GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover. 5.6.2 StormSentry shall not be left exposed for longer than 90-days after installation, prior to placement of final roof cover. 5.6.3 Alcazar, Boral TileSeal 50"T and Boral TileSeal"T shall not be left exposed for longer than 180- days after installation, prior to placement of final roof cover. 5.6.4 Citadel, for used as a base-layer in a two-ply underlayment system, shall not be left exposed for longer than 180-days after installation, prior to placement of subsequent underlayment layer. 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self-Adhered Underlayment Requirements" for limitations for self-adhering underlayments used beneath tile roof systems. Table 2:Tile System Options per FRSA/TRI 07320/8-05 System Underlay Option Section Reference Product(s) 1 3.02A Single-Ply No. 43 Alcazar 4 3.02D 43 o Ply No. 30 or No. Alcazar System One: Mechanically 5 3.02E Self-Adhered Base Layer: (Optional)Citadel HT Fastened Tile, Underlayment Top Layer: Boral TileSeal Unsealed or Sealed Self-Adhered Underlayment 5 3.02E Underlayment StormSentry System 6 3.02E No. 30/Self-Adhered Base Layer:ASTM D226,Type II or Alcazar Underlayment Top Layer: Boral TileSeal"T 6 3.02E No. 30/Self-Adhered Base Layer:ASTM D226,Type II Underlayment Top Layer: StormSentry 4 3.02D Self-Adhered Base Layer: (Optional)Citadel Underlayment Top Layer: Boral TileSeal"T System Two: Mechanically4 3.02E Self-Adhered StormSentry Fastened Tile, Underlayment Sealed No. 30/Self-Adhered Base Layer:ASTM D226,Type II or Alcazar Underlayment 5 3.02E Underlayment Top Layer: Boral TileSeal"T System 5 3.02E No. 30/Self-Adhered Base Layer:ASTM D226,Type II Underlayment Top Layer: StormSentry Exterior Research and Design, LLC. Evaluation Report M35710.12.10-R2 Certificate ofAuthorization#9503 FL14317-R1 Revision 2: 06/24/2011 Page 4 of 9 no TRINITY ERa Table 2(continued):Tile System Options per FRSA/TRI 07320/8-05 System Four"A": Self-Adhered Base Layer: (Optional)Citadel Adhesive-Set Tile, 4 3.02D Underlayment Top Layer: Boral TileSeal"T Unsealed or Sealed Underlayment 5 3.02E No. 30/Self-Adhered Base Layer: ASTM D226,Type II or Alcazar System Underlayment Top Layer: Boral TileSeal"T System Four"B": Self-Adhered Base Layer: (Optional)Citadel Adhesive-Set Tile, 3 3.02C Underlayment Top Layer: Boral TileSeal"T Sealed Underlayment No. 30/Self-Adhered Base Layer: ASTM D226,Type II or Alcazar System 4 3.02D Underlayment Top Layer: Boral TileSeal"T 6. INSTALLATION: 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 40°F and rising. 6.4 Alcazar 6.4.1 Install Alcazar in compliance with manufacturer's published installation instructions and the requirements for ASTM D226, Type I and II or ASTM D2626 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Address metal drip-edge, rakes, valleys and penetrations in accordance with Boral Roofing published installation instructions. 6.4.3 Slopes of 4:12 or greater: 6.4.3.1 Starting at the eaves, lay Alcazar underlayment, lapping each course minimum 2-inches (horizontal lap) and with minimum 6-inch end (vertical) laps. At all head (horizontal) laps, pull the release film from the bottom of the overlapping course and fully adhere to the selvedge edge of the course below. End (vertical) laps in a succeeding course shall be staggered from those in preceding course by minimum 6-feet. 6.4.3.2 Secure with standard roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails maximum 6-inch o.c. at the laps and 12-inch o.c. in two, equally spaced, staggered rows in the center of the sheet. 6.4.3.3 If a top-layer-underlayment is required atop the mechanically attached base layer, install Boral TileSeal 50"T, Boral TileSeal"T or GatorSeal in accordance with Boral Roofing published installation instructions and the applicable sections below. Exterior Research and Design, LLC. Evaluation Report M35710.12.30-112 Certificate ofAuthorization#9503 FL14317-R1 Revision 2: 06/24/2011 Page 5 of 9 TRINITY ER.D 6.4.4 Slopes of 3:12 to less than 4:12: 6.4.4.1 Double layer application; begin by fastening a 19-inch wide strip of Alcazar underlayment placed along the eaves. Place a full-width sheet over the starter, completely overlapping the starter course. Overlap succeeding courses by 19-inches. Minimum 6-inch end (vertical) laps shall be staggered from those in preceding course by minimum 6-feet. 6.4.4.2 Secure the top layer with standard roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails maximum 6-inch o.c. at the laps and 12-inch o.c. in two, equally spaced, staggered rows in the center of the sheet. 6.4.5 For use in asphalt-shingle applications, reference is made to the current edition of the ARMA Asphalt Roofing Manual. For use in applications that do not involve asphalt-shingles or tile, reference is made to the current edition of the NRCA Steep-slope Roofing Manual. 6.4.6 For use in tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4.6.1 Boral Roofing published attachment requirements, as noted above, for Alcazar are more stringent than and take precedence over those published in FRSA/TRI 07320/8-05. 6.5 Citadel: 6.5.1 Citadel is limited to use as a base-layer in two-ply underlayment systems beneath Boral TileSeal 50"T, Boral TileSeal "T or GatorSeal. 6.5.2 Slope limitations are those associated with the top-layer underlayment. 6.5.3 Direct to deck: 6.5.3.1 Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by 1/4-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. 6.5.3.2 Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the width of the black-selvedge area, minimum 3-inch. 6.5.3.3 Seal under end (vertical) laps using approved mastic, or use Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. 6.5.3.4 Install final underlayment layer atop Citadel. 6.5.4 To mechanically attached base sheet: 6.5.4.1 Install Alcazar in accordance with Boral Roofing published installation instructions and Section 6.4.3 or install ASTM D226, Type II felt in accordance with Section 6.4.3 but using minimum 4-inch head (horizontal) laps. 6.5.4.2 Install Citadel in accordance with Boral Roofing published installation instructions and Section 6.5.3, except end (vertical) laps, described below. 6.5.4.3 Apply SBS Mastic under all end (vertical) laps, rolling the interface into place with a weighted roller. 6.5.4.4 Install final underlayment layer atop Citadel. Exterior Research and Design, LLC. Evaluation Report M35710.12.10-R2 Certificate ofAuthorization#9503 FL14317-R1 Revision 2: 06/24/2011 Page 6 of 9 TRINITY ERD 6.6 Boral TileSeal 50"T: 6.6.1 Install Boral TileSeal 50"T in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.6.2 Do not use Boral TileSeal 50"T on roof pitches less than 2:12. 6.6.3 For non-tile applications, direct to deck: 6.6.3.1 Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by 1/4-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. 6.6.3.2 Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the width of the black-selvedge area, minimum 3-inch. 6.6.3.3 Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. 6.6.4 For non-tile applications, to mechanically attached base sheet: 6.6.4.1 Install Alcazar in accordance with Boral Roofing published installation instructions and Section 6.4.3 or install ASTM D226, Type II felt in accordance with Section 6.4.3 but using minimum 4-inch head (horizontal) laps. 6.6.4.2 Install Boral TileSeal 50"T in accordance with Boral Roofing published installation instructions and Section 6.6.3, except end (vertical) laps, described below. 6.6.4.3 Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.7 GatorSeal and StormSentry: 6.7.1 Install GatorSeal and StormSentry in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.7.2 Do not use GatorSeal or StormSentry on roof pitches less than 2:12. For tile applications (StormSentry only), do not use StormSentry on roof pitches less than 21/2:12, 6.7.3 For non-tile applications, direct to deck: 6.7.3.1 Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by 1/4-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. 6.7.3.2 Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the width of the black-selvedge area, minimum 3-inch. 6.7.3.3 Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. Exterior Research and Design, LLC. Evaluation Report M35710.12.10-R2 Certificate of Authorization#9503 FL14317-R1 Revision 2: 06/24/2011 Page 7 of 9 ry` TRINITYI ERD 6.7.4 For non-tile aoolications, to mechanically attached base sheet: 6.7.4.1 Install Alcazar in accordance with Boral Roofing published installation instructions and Section 6.4.3 or install ASTM D226, Type II felt in accordance with Section 6.4.3 but using minimum 4-inch head (horizontal) laps. 6.7.4.2 Install GatorSeal (over Alcazar or ASTM D226, Type II felt) or StormSentry (over ASTM D226, Type II felt only) in accordance with Boral Roofing published installation instructions and Section 6.7.3 except end (vertical) laps, described below. 6.7.4.3 Apply SBS Mastic under all side (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the granular top surface, rolling the interface into place with a weighted roller. 6.7.5 For tile applications (StormSentry only): 6.7.5.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.8 Boral TileSeal "T: 6.8.1 Install Boral TileSeal HT in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.8.2 Do not use Boral TileSeal HT on roof pitches less than 2:12. For tile applications, do not use Boral TileSeal HT on pitches less than 21/2:12. 6.8.3 For non-tile applications, direct to deck: 6.8.3.1 Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by 1/4-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. 6.8.3.2 Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the width of the black-selvedge area, minimum 3-inch. 6.8.3.3 Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. 6.8.4 For non-tile applications, to mechanically attached base sheet: 6.8.4.1 Install Alcazar in accordance with Boral Roofing published installation instructions and Section 6.4.3 or install ASTM D226, Type II felt in accordance with Section 6.4.3 but using minimum 4-inch head (horizontal) laps. 6.8.4.2 Install Boral TileSeal HT in accordance with Boral Roofing published installation instructions and Section 6.8.3, except end (vertical) laps, described below. 6.8.4.3 Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. Exterior Research and Design, LLC. Evaluation Report M35710.12.10-R2 Certificate ofAuthorization#9503 FL14317-R1 Revision 2: 06/24/2011 Page 8 of 9 TRINITY ESQ 6.8.5 For the applications: 6.8.5.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.8.5.2 Battens must be used for all tile installations atop Boral TileSeaI HT with roof pitches of 21/z to less than 3:12. Boral Roofing's Elevated Batten System, Tru-Flow Battens or counter battens are required. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories — QUA1743; (414) 248-6409; Karen.buchmann@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report M35710.12.10-112 Certificate of Authorization#9503 FL14317-R1 Revision 2: 06/24/2011 Page 9 of 9