Loading...
710 Sailfish Dr right of way permit ,i y�Jyr r CITY OF ATLANTIC BEACH r 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROW18-0013 Description: install 35-ft. class 4 wood pole Estimated Value: 0 Issue Date: 4/30/2018 Expiration Date: 7/29/2018 PROPERTY ADDRESS: Address: 710 SAILFISH DR RE Number: 171209 0000 PROPERTY OWNER: Name: FLORIDA SUNRISE PROPERTIES LLC Address: P O BOX 1372 PONTE VEDRA BEACH, FL 32004-1372 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JACKSONVILLE ELECTRIC AUTHORITY Address: 21 CHURCH ST W 3RD FLR JACKSONVILLE, FL 32202 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. Permit Number: ROW18-0013 Description: install 35-ft.class 4 wood pole Applied:4/23/2018 Approved: 4/26/2018 Site Address: 710 SAILFISH DR Issued:4/30/2018 Finaled: City,State Zip Code: Atlantic Beach, FI 32233 Status: ISSUED Applicant: <NONE> Parent Permit: Owner: FLORIDA SUNRISE PROPERTIES LLC Parent Project: Contractor: <NONE> Details: LIST OF CONDITIONS SEQ NO I ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 4/25/2018 UNDERGROUND WATER SEWER INFORMATIONAL UTILITIES PUBLIC WORKS Kayle Moore Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5834. 2 4/25/2018 UTILITY MAP INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: See attached Utility Map. 3 4/26/2018 ON SITE RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site during construction. 4 4/26/2018 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. Printed: Monday, 30 April, 2018 1 of 1 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road _ Atlantic Beach, Florida 32233-5445 ©(3 Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us APR 2 n Date routed: City web-site: http://viww.coab.us 4 20it} APPLICATION REVIENV-ANB-TRACKING FORM Property Address: -1 � 0SLf �1.���� Department review required Yes No Building Applicant: l— !C Planning &Zoning r T Administrator Project: 115 �� �J - � - G��SS�w�J� or s P� Q Public ies Pu is Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receiptof Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by,4� Date: TREE ADMIN. Second Review: []Approved as revised. []Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 cPJJr, City of Atlantic Beach APPLICATION NUMBER ��•. JS s� Building Department (To be assigned by the Building Department.) L: 800 Seminole Road c� _ Atlantic Beach, Florida 32233-5445 V oL 0 G Phone(904)247-5826 • Fax(904) 247-5845 J is) E-mail: building-dept@coab.us Date routed: City web-site: http://vvww.coab.us APR 2 4 201: 11 APPLICATION REVIEW AND TRACKING FORM Property Address: S�� �,��� �J� ` Department review required Yes No Building Applicant: Planning &Zoning I T Administrator Project: !15 �! 3�- - GIUSS����� or s P6QlPublic i ies Pubic Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING /� ' ` I _ t� PLANNING &ZONING Reviewed by: "''_ Date: / �g TREE ADMIN. Second Review: ❑Approved as revised. [-]Denied. ❑Not applicable P WORK, Comments: E� - UBLI UTILITIES —Z j f/ PU LIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. [-]Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 F 7 729 q 721 a 71 • M DR Ey FIELD VERIFY/HAND DIG TO LOC14E WATER MAIN LOCATION. 700 f. { _ RIGHT-OF-WAY/EASEMENT PppERMIT�j Permit#Issued by the City of Atlantic Beach F �`"� p a0 PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 9 /0 Sar�It-,5 � 0/_- Phone 6G3-- 7783 Pennittee J r(4 Email *S%--h(2 R a i,)e oi i Requesting Permission to Construct (/ ) 35" [ lu+s t Cl I.wo-4d /a T -�v 5, Z. Location(Reference to Cross-Street) • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of (Project Superintendent) with Company Name Phone (,d 1`275 3 • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within (v0 days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be notified twenty-four(24)hours prior to starting work and again immediately upon completion. Date Permittee(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this day of 120 by who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. Personally Known Signature of Notary Public,State of Florida Produced Identification(Type) ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:33557 N.0.: 8004473 WO#: 30278824 CONSTL44648- CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 563 REQ'D:NO CELL ENGINEER:Robert Simpson N.0.: N/A ZIP CODE: N/A CUSTOMER/ SVC PHONE LOCATION: 714 SAILFISH DRJ POLE INSTALL 563 CENTER: SSSC N.O.:665.7793 I I STA 1. P# 714 SAILFISH DRJ 35/4W - 1104 POLE INSTALL. RUN VOT TO STA 2, 100A 1006 STA 2. P# 733 SAILFISH DR. OOC 751 743 STA 2 0 735 729 721 1/OT LnQ � 0 ^ N 1/OT ® ® 713 705 2-6CU 2-6CU 1/0^ Q Q LO 1/OT 2T SAILFIS�f4l \ 4/OP VOT VOT \' 1/OT 4T 1 ® 6CG 750 735 740 730 0 0 725 715 722 0 710 c i 681 6 0 STA 1 50P, VOT VOTa r 6 ' +Ln -6CU 1/OT 2 6`�O PLAZA i ~ ~MBE 'JA T 1 66 1/OT o r 1 25 VOT 4T 0 , 1 o v 1 724 © 712 725 715 700 0 e 705 t r CN ® t CUE Reports Estimate Number:33557 714 SAILFISH./35/4W POLE Estimate Type:SR Contractor:HENKELS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#/Task:30278824 Required Date: Oracle Project#:8004473 Estimated On: 04/23/2018 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $555.84 $555.84 2.Transformer Cost(w/sales tax) $0.00 $0.00 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $263.64 $761.78 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $184.04 $116.17 7.Engineering Costs(Variable%of line 4) $73.69 $212.92 8.Project Equipment Costs(40%of total equipment costs) $151.46 $0.00 9.Material Handling(8.30%of lines 1 &2) $46.13 $46.13 10.Inspection(6.84%of line 4) $0.00 $52.11 11.Total Cost of Project $1,274.80 $1,744.94 12.Work Order Estimate(Line 11 minus line 8,9,&10) $1,077.20 $1,698.81 13.Billable Equipment Depreciation(60%of total equipment costs) $227.19 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11+13+(58.71%of 4&7)) $1,700.04 $1,869.95 15.Billing Estimate(W/O Transformer Cost)(Lines 11+13+(58.71%of 4&7)-Line 2) $1,700.04 $1,669.95 Time Estimate Crew Hours Total Manhours 2.11 8.46 I_ CUE Reports Estimate Number:33557 714 SAILFISH./35/4W POLE Estimate Type:SR Contractor:HENKELS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#/Task:30278824 Required Date: Oracle Project#:8004473 Estimated On: 04/23/2018 CU Detail Build Transfer Remain in Place Remove C.1/0T 80 G3W 1 G3W*2 1 GY3 1 GY3*5 1 P.35/4W 1 S4 1 S4`1/0 1 Build Transfer Remain in Place Remove RUBUP 2 S20ES`2/0-1/0 1 S4'1/0 1 RUBDOWN 2 CUE Reports Estimate Number.33557 714 SAILFISH./35/4W POLE Estimate Type:SR Contractor:HEN KELS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#/Task:30278824 Required Date: Oracle Project M 8004473 Estimated On: 04/2312018 Conductor, Conduit and Pipe Detail Quantities From Station To Station CU Build Transfer Remain Remove 01 2 C.1/OT 80 0 0 0 I. CUE Reports Estimate Number:33557 714 SAILFISH./35/4W POLE Estimate Type:SR Contractor:HEN KELS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#ITask:30278824 Required Date: Oracle Project#:8004473 Estimated On: 04/23/2018 Material Summary Item Quantity Item Number Item Description 2 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZED 10"X 8'X 1-1/4", SHIP ON OPEN FLATBED ONLY! 2 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 80 CA10SO09 CABLE, 1/0 TRIPLEX, OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX CABLE"ECHINUS" 1500 FOOT REELS 2 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 1 CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE:46-2/0 2 CLASS004 CLAMP, STRAIGHT STRAIN,ALUMINUM, 5000#,4-3/0 ALUM 5 CNNCP002 CONNECTOR,#2, 6-2 MAIN, 2-1/0 TAP, ALUMINUM COMPRESSION, PARALLEL TAP, 2 CNNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 1 CNNCP005 CONNECTOR,#3, 6-2 MAIN, 2/0-3/0 TAP, COMPRESSION, PARALLEL TAP,ALUMINUM, 4 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 22 COBC0028 CONDUCTOR,#4 SOLID, SOFT DRAWN, BARE COPPER, 200',25#, ON PLASTIC REEL,4"X 11.5"W/2"HOLE 140 COBCW014 CONDUCTOR,#4,TYPE 40 DSA,COPPERWELD&COPPERWELD- COPPER.204"DIAMETER 1480#BREAKING STRENGTH (50#COIL- 427' ) 2 COVIC002 COVER, "D" DIE, INSULATING, 2-1/2" 2 GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 2 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL 3/8"AND 7/16" GUY STRANDS(DISTRIBUTION) 2 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE, 20,000 LB MIN, ULT. STRENGTH, FOR WOOD OR CONCRETE POLES 4 GUYGRO01 GRIP, GUY, 3/8", 26", GALVANIZED 100 GUYST005 STRAND, GUY, 3/8"DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS "B"GALV. OR BEZINOL IS ACCEPTABLE (500'COIL) 1 INSGB002 INSULATOR, STRAIN, GUY BREAKER, 21,000#RATED,60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 3 INSS0002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 1 POLW0003 POLE,WOOD, 35'CLASS 4 (T/L=44),WEIGHT=1,026 LBS 2 RODGRO03 ROD, GROUND, THREADLESS, 5/8"X 8', SHIP ON OPEN FLATBED ONLY! 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5"HIGH X 2" WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 2 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X 2" DIAMETER, GALVANIZED,*** 500 EACH PER BOX*** CUE Reports Estimate Number:33557 714 SAILFISH./35/4W POLE Estimate Type:SR ContractorHENKELS 8 MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#!Task:30278824 Required Date: Oracle Project M 8004473 Estimated On: 04/23/2018 2 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4",5/8"X 3/4"BOLT SIZE, GALVANIZED 2 WASSP002 WASHER, SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED (EXTRA HEAVY DUTY) CUE Reports Estimate Number:33557 714 SAILFISH./3514W POLE Estimate Type:SR Contractor:HENKELS&MCCOY INC INSTALL Estimate Version: By: SIMPRB MWO#lTask:30278824 Required Date: Oracle Project#:8004473 Estimated On: 04/23/2018 Cid Summary Cu Name guantity Description C.1/OT 80 1/0 TRIPLEX G3W*2 1 WOOD POLE- NON-EQUIPMENT GROUND GY3*5 1 GY3*5 3/8"DOWNGUY W/8 FT SCREW ANCHOR P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 2 LINE RUBBER INSTALLATION, PER SECT. S20ES*2/0-1/0 1 S20 ES*2/0-1/0 S4*1/0 2 SECONDARY DEADEND CU Name Quantity Description RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT.