Loading...
403 Atlantic - Permit COMM17-00070 TOILET O 0 O 1' Fol TOILET O I', I STOCKROOM we • DISPLAY EXISTING FLOOR PLAN PLAN % SCALE: 1 /4" = 1'-0" • IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY 0 2' 4' 8' SCALE: 1/4" = 1' PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD2ml co 00 �+ m N U Lu 0 Q Z Lu O J U w a (D co Z U � 0 N N 0 co Q J co 0 LL `O u- O vi � U � L (D °' M w J I— Z cuo Jm X H W Lu wa U u () H a CO O N Lo M N r--:_ •� N cn O L O Z b O X ca C/3 V- N C ti O O Q � N M � m O W M � PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD2ml M M N N co Z Lu J LL Q Z Lu = U J U w a (D co Z U � 0 wQ 0 �J Q J LL G � Z � z> — w J I— Z o Jm X H W Lu wa J LL H a M O It PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD2ml 00 -,p 2 D PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD2ml EXISTING ILLUMINATED - -- EMERGENCY EXIT SIGN TO REMAIN REMOVE EXISTING - SURFACE -MOUNTED LIGHT FIXTURE (ABOVE) AND PREP FOR NEW LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS U TOILET L DIMENSION TO BE TAKEN FROM EDGE OF EXISTING CMU PILASTER - DESIGN INTENT IS TO ALIGN NEW MASONRY OPENINGS WITH EXISTING CMU JOINTS; ADJUST AS REQUIRED. 11 - t7,-5112 REMOVE EXISTING CABINET, SHE L ES, TOILET ACCESSORIES, AND FLOOR AND WALL FINISHES - PREP FLOORS AND WALLS FOR NEW FINISHES REMOVE AND REINSTALL EXISTING GRAB BARS SO TOP OF GRAB BAR IS 36" A.F.F. t REMOVE EXISTING ELECTRIC WAT R COOLER AND PREP WATER ANDS NITARY FOR NEW HIGH -LOW COMBINATIO ELECTRIC WATER COOLER -SEE PLUMBING DRAWINGS • DISPLAY �. 0 1 U ° L REMOVE AND RELOCATE TOILET �D L I EXISTING A/C EXTERIOR p✓C REMOVE ALL EXISTING CONDENSING UNIT TO I PLUMBING FIXTURES IN REMAIN, TYPICAL I TOILET ROOM - CAP PLUMBING IN WALL AND BELOW FLOOR AS REQUIRED A/C .4" 51-411- SELECTIVELY ,-4„SELECTIVELY DEMO PORTION OF EXISTING WALL FOR NEW ALUMINUM -FRAMED STOREFRONT WINDOW, TYPICAL - SEE EXTERIOR ELEVATION 3/AD3.1 STOCKROOM A/C EXISTING DOOR & FRAME TO NEW IT/ELEC 112 �- EXISTING WALL TO BE REMOVED, TYPICAL NOTES: 1. REMOVE ALL EXISTING MERCHANDISING EQUIPMENT, CABINETS, FURNITURE, DISPLAY RACKS, ETC. 2. REMOVE ALL EXISTING ACOUSTICAL TILE CEILINGS. 3. REMOVE ALL EXISTING FLOOR FINISHES. 4. REMOVE ALL EXISTING FRP WALL PANELS FROM WALLS INDICATED TO REMAIN. tt6.7 1 EXISTNG STEEL PIPE COLUMN, TYPICAL EXISTING COUNTERTOP AND CABINETS TO BE REMOVED U > I U / EXISTNG STEEL PIPE COLUMN WITH 8" X 8" BASE PLATE, TYPICAL SELECTIVELY DEMO PORTION OF EXISTING WALL FOR NEW ALUMINUM -FRAMED STOREFRONT AND ENTRANCE DOOR - SEE EXTERIOR ELEVATION 1/AD3.1 REMOVE E WALKWAY STING CONCRETE /HERE HATCHED SELECTIVE DEMQLITION PLAN SCALE: 1/4" = 1'-0" 314" 6'-8" 4'-011 L - - - - - `- EXISTING WALL TO REMAIN, TYPICAL EXISTING ALUMINUM -FRAMED STOREFRONT TO REMAIN, TYPICAL EXISTING MONUMENT SIGN TO BE REMOVED 0 2' 4' 8' SCALE: 1/4" = 1' IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY I_ SELECTIVE DEMOLITION GENERAL NOTES A. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION. B. IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN THE WORK; HOWEVER, IF HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ARCHITECT AND LANDLORD. C. VERIFY THAT EXISTING UTILITIES HAVE BEEN SHUT OFF PRIOR TO STARTING SELECTIVE DEMOLITION OPERATIONS. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. D. EXISTING WARRANTIES: REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND SURFACES CUT OR DAMAGED DURING SELECTIVE DEMOLITION, BY METHODS AND WITH MATERIALS AND USING APPROVED CONTRACTORS SO AS NOT TO AVOID EXISITING WARRANTIES. NOTIFY WARRANTOR BEFORE PROCEEDING. VERIFY EXISTING WARRANTED SYSTEMS WITH LANDLORD PRIOR TO SELECTIVE DEMOLITION. E. EXISTING HVAC AIR HANDLERS AND EXTERIOR CONDENSING UNITS SHALL REMAIN AND MUST BE PROTECTED AGAINST DAMAGE FROM SELECTIVE DEMOLITION OPERATIONS. F. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION AS REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO ADJACENT BUILDINGS AND FACILITIES TO REMAIN. G. PROVIDE PROTECTION TO INSURE SAFE PASSAGE OF PEOPLE AROUND SELECTIVE DEMOLITION AREA. H. PROVIDE TEMPORARY WEATHER PROTECTION, DURING INTERVAL BETWEEN SELECTIVE DEMOLITION OF EXISTING CONSTRUCTION ON EXTERIOR SURFACES AND NEW CONSTRUCTION, TO PREVENT WATER LEAKAGE AND DAMAGE TO STRUCTURE AND INTERIOR AREAS. I. PROTECT WALLS, CEILINGS, FLOORS AND OTHER EXISTING FINISHES THAT ARE TO REMAIN OR THAT ARE EXPOSED DURING THE SELECTIVE DEMOLITION PROCESS. J. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND AS REQUIRED: J.A. PROCEED WITH SELECTIVE DEMOLITION SYSTEMATICALLY, FROM HIGHER TO LOWER LEVEL. J.B. NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE, AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION. USE HAND TOOLS OR SMALL POWER TOOLS DESIGNED FOR SAWING OR GRINDING, NOT HAMMERING OR CHOPPING. TEMPORARILY COVER OPENINGS TO REMAIN. J.C. REMOVE DECAYED, VERMIN -INFESTED, OR OTHERWISE UNSUITABLE MATERIALS AND PROMPTLY DISPOSE OFF-SITE. J.D. REMOVE SELECTIVE DEMOLITION MATERIALS AND LOWER TO GROUND BY METHOD SUITABLE TO AVOID FREE FALL AND TO PREVENT GROUND IMPACT OR DUST GENERATION. J.E. LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND MATERIALS SO AS NOT TO IMPOSE EXCESSIVE LOADS ON SUPPORTING WALLS, FLOORS, OR FRAMING. J.F. DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY. DO NOT ALLOW THEM TO ACCUMULATE ON-SITE. COMPLY WITH HAULING AND DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION. K. REMOVED AND, REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT. PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED. L. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. M. SELECTIVE DEMOLITION FOR CONCRETE SLABS ON GRADE: SAW -CUT PERIMETER OF AREA TO BE DEMOLISHED, AND THEN BREAK UP AND REMOVE. N. SELECTIVE DEMOLITION FOR MASONRY: DEMOLISH IN SMALL SECTIONS. CUT MASONRY AT JUNCTURES WITH CONSTRUCTION TO REMAIN, USING POWER -DRIVEN SAW, AND THEN REMOVE MASONRY BETWEEN SAW CUTS. 0. SELECTIVE DEMOLITION FOR RESILIENT FLOOR COVERINGS: REMOVE FLOOR COVERINGS AND ADHESIVE ACCORDING TO RECOMMENDATIONS IN RFCI'S "RECOMMENDED WORK PRACTICES FOR THE REMOVAL OF RESILIENT FLOOR COVERINGS. 1 W co co Z a' �--+ U � N 0 W F_ 0 CDi z= ZU w O N m � N J Y Q O C" Q W 0Li- 0 Z> Q W U LM' co W L V J Q F_ LU F_ J o ♦W cn Y Q U M 0 d- co N U")N ECD M ~ -� N N -g- O C> 0X � Z o c/5 LJ_ a� ti Q N M 0 W M 2 PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB I AD2m2 M Z N Q � M W F_ —j LL z= ZU w O (D m � Z J Y Q O ot� Q W � o Z> Q W o > Z 0 V J m U F_ LU F_ J wa ♦W LL. Q M 0 d- PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB I AD2m2 .� c L O PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB I AD2m2 EXISTING ALUMINUM GUARDRAIL, TYPICAL EL +10'-0" TOP OF MASONRY OPENING EL +2'-0" I i� II II II II II II Il II BOTT. OF MASONRY OPENING EXISTING WALL -MOUNTED LIGHT FIXTURE, TYPICAL REMOVE EXISTING DOOR CLOSERS, PUSH BAR, PULL HANDLE AND ADHESIVE -APPLIED STREET ADDRESS FROM ENTRANCE DOOR AND PATCH & REPAIR DOOR AND FRAME AS REQUIRED. NOTE: ENTRANCE DOOR TO REMAIN OPERA IONAL UNTIL NEW ALUMINUM -FRAMED ENTRANCE OOR AND SIDELIGHT ARE INSTALLED ON WEST E EVATION EXISTING WEST ELEVATION SCALE: 1/4" = V-0" EXISTING "RADIO SHACK" SIGN TO BE REMOVED r ------------------- ---------------L-------------------J L ------------------- J EXISTING ALUMINUM -FRAMED STOREFRONT, TYPICAL EXISTING SOUTH ELEVATION SCALE: 1/4" = V-0" EQ. 12'-8" EQ. -1 (VERIFY) 0 0 T_ SELECTIVELY DEMO PORTION OF EXISTING WALL TO PROVIDE MASONRY OPENING FOR NEW ALUMINUM -FRAMED STOREFRONT WINDOW, TYPICAL J EXISTING EAST ELEVATION SCALE: 1 /4" = V-0" EXISTING HOLLOW METAL DOOR & FRAME EXISTING MONUMENT SIGN TO BE REMOVED REMOVE EXISTING WALL -MOUNTED LIGHT FIXTURE REMOVE PORTION OF EXISTING TRIM TO ACCOMMODATE WIDTH OF NEW AWNING (BY OTHERS) EL +10'-0" TOP OF MASONRY OPENING SELECTIVELY DEMO PORTION OF EXISTING WALL TO PROVIDE MASONRY OPENING FOR NEW ALUMINUM -FRAMED STOREFRONT AND ENTRANCE DOOR - REMOVED EXISTING POWER TO MONUMENT SIGN L 0 0 2' 4' 8' SCALE: 1/4" = 1' PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD3ml IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY I II M M N N �ENB Lucn P J , Oz F— Z= LLJ v U w J F— � Z m cn L cQ m co -�-+ U Q °' N 0 LLI�d >��> —O z 0 CDi V� Z w 0 WWQm JX � W w F- �W a N N Q M 0 E 0 LLU o U L cuL °' m 0 M `u 1 .1..1 �� > c c o o Y U co � co N � M N ~ �N 0 o L a, z 0 o x M cn L.L. a c rn > rn o? - N C 0 cn W M� PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD3ml IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY I II M M N N Lucn P J , Oz F— Z= LLJ v U w J F— � Z m WW�� L cQ Z OJ W Q Q LLI�d >��> —O z V� Z w 0 WWQm JX � W w F- �W a --i� L Q 0 PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD3ml IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY I II LO e — O � L cQ s Q PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD3ml IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY I II SS2.1 S2.1 SLAB PLAN SCALE: 1/4" = V-0" 101 S2.1 EXISTING STEEL COLUMN TO CUT OFF V NEW WINDOW OPENING AND BE FILLED WITH GROUT 0 GENERAL NOTES 100. DESIGN CRITERIA 100.1 DESIGN BUILDING CODE: A. FLORIDA BUILDING CODE, 2014 100.2 GRAVITY LOADS: A. ROOF LIVE LOADS: 1. FLAT ROOF 20 PSF 100.3 LATERAL LOADS: A. WIND LOADS (IN ACCORDANCE WITH DESIGN BUILDING CODE PER GENERAL NOTE 100.1): 1. ULTIMATE DESIGN WIND SPEED (3 SECOND GUST), Vult = 129 MPH 2. NOMINAL DESIGN WIND SPEED (3 SECOND GUST), Vasd = 100 MPH 3. RISK CATEGORY = 11 4. EXPOSURE CATEGORY = C 5. ENCLOSURE CLASSIFICATION = ENCLOSED 6. INTERNAL PRESSURE COEFFICIENT (GCpi) = +/-0.18 7. WALL COMPONENTS AND CLADDING PRESSURES, Pult = +/- 47 PSF 110.2 110.3 110.4 110.5 110.6 120. 120.1 120.2 120.3 120.4 120.5 120.6 T, THESE DRAWINGS HAVE BEEN PRODUCED ENTIRELY ON ATLANTIC ENGINEERING SERVICES CADD SYSTEM. ANY OTHER LETTERING, LINES OR SYMBOLS, OTHER THAN PROFESSIONAL STAMPS AND SIGNATURES, HAVE BEEN MADE WITHOUT THE AUTHORIZATION OF ATLANTIC ENGINEERING SERVICES AND ARE INVALID. THE STRUCTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL STRUCTURAL FEATURES, UNLESS NOTED OTHERWISE. THE ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL DIMENSIONS. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. ONLY DIMENSIONS INDICATED ON DRAWINGS MAY BE USED TO ESTABLISH THE LOCATION AND EXTENT OF STRUCTURAL WORK. IF A REQUIRED DIMENSION IS NOT FURNISHED ON DRAWINGS, THE CONTRACTOR SHALL SUBMIT A REQUEST FOR INFORMATION TO OBTAIN THE DIMENSION. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ETC., AND SHALL NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES, ADDITIONAL INFORMATION, ETC., BEFORE BEGINNING THE WORK. THE CONTRACTOR SHALL USE EXTREME CAUTION IN THE DEMOLITION OF EXISTING STRUCTURES. SUCH DEMOLITION SHALL BE PERFORMED IN SUCH A MANNER AS TO MAINTAIN THE STRUCTURAL INTEGRITY OF ALL EXISTING STRUCTURES TO REMAIN. PROVIDE SHORING AS REQUIRED. ALL STRUCTURAL WORK SHALL BE INSPECTED IN ACCORDANCE WITH THE BUILDING CODE AND ALL LOCAL ORDINANCES. THE OWNER SHALL ENGAGE AN EXPERIENCED, QUALIFIED TESTING/INSPECTION AGENCY, SUBJECT TO THE REVIEW OF THE ARCHITECT, TO PERFORM ALL INSPECTION WORK, AS REQUIRED. SHOP DRAWINGS THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW BY ATLANTIC ENGINEERING SERVICES AND THE PROJECT ARCHITECT. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL COMPONENTS INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: A. REINFORCING STEEL FOR CONCRETE AND MASONRY B. CONCRETE GROUT MIX DESIGN C. CONCRETE AND/OR MASONRY POST -INSTALLED ANCHORS SHOP DRAWINGS TO BE SUBMITTED SHALL PROVIDE COMPLETE INFORMATION FOR THE PRODUCTS OR COMPONENTS TO BE SUPPLIED. SUBMITTAL INFORMATION SHALL INCLUDE, BUT NOT BE LIMITED TO: MEMBER SIZES AND DIMENSIONS; GRADES OF MATERIAL FURNISHED; MATERIAL PREPARATION REQUIRED; MATERIAL FINISH AND MATERIAL COATINGS TO BE FURNISHED; INFORMATION REGARDING CUTS, COPES, AND HOLES REQUIRED FOR OTHER TRADES; END CONNECTIONS; CAMBER AND OTHER DEVIATION FROM LINE; SPECIAL ERECTION AND/OR INSTALLATION PROCEDURES, INCLUDING REQUIREMENTS FOR TEMPORARY STABILIZATION. ALL SHOP DRAWING RESUBMITTALS AND RECORD COPY SUBMITTALS SHALL HAVE ALL REVISIONS SUBSEQUENT TO THE PREVIOUS SUBMISSION CLOUDED OR OTHERWISE IDENTIFIED ON THE RESUBMITTED SHEETS. RESUBMITTALS AND RECORD COPY SUBMITTALS WITHOUT IDENTIFICATION OF REVISIONS WILL BE REJECTED WITHOUT REVIEW. THE CONTRACTOR SHALL NOT DIRECTLY INCORPORATE THE STRUCTURAL DRAWINGS, OR PORTIONS THEREOF, INTO SHOP DRAWINGS OR ERECTION DRAWINGS TO BE SUBMITTED FOR THIS PROJECT WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION OF ATLANTIC ENGINEERING SERVICES. SUBMITTED SHOP DRAWINGS WHICH CONTAIN COPIES OR REPRODUCTIONS OF ANY PORTION OF THE STRUCTURAL DRAWINGS WITHOUT THE EXPRESS WRITTEN PERMISSION OF ATLANTIC ENGINEERING SERVICES WILL BE RETURNED REJECTED. PERMISSION FOR A SPECIFIC CONTRACTOR OR SUB -CONTRACTOR TO USE PORTIONS OF THE STRUCTURAL DRAWINGS IN THEIR PREPARATION OF SHOP DRAWINGS REQUIRES THAT CONTRACTOR OR SUB -CONTRACTOR TO ENTER INTO A WRITTEN AGREEMENT WITH ATLANTIC ENGINEERING SERVICES AND TO PAY A SERVICE FEE. SUCH AGREEMENT IS NON-TRANSFERRABLE AND IS EXTENDED ONLY TO THAT CONTRACTOR FOR THE DURATION OF THIS PROJECT. THE CONTRACTOR SHALL SUBMIT ELECTRONIC COPIES OF SHOP DRAWINGS IN LIEU OF PRINTED COPIES. COPIES SHALL BE SUBMITTED TO ATLANTIC ENGINEERING SERVICES IN PDF FILE FORMAT (ISO 32000-1), WITH ONE (1) ELECTRONIC FILE PER SUBMISSION. ATLANTIC ENGINEERING SERVICES WILL REVIEW, ANNOTATE, AND RETURN ONE (1) FILE TO THE ARCHITECT FOR THEIR REVIEW AND DISTRIBUTION TO THE CONTRACTOR. THE REVIEW OF SHOP DRAWINGS AND OTHER SUBMITTALS FOR THIS PROJECT IS FOR CONFORMANCE WITH THE DESIGN CONCEPT AND FOR GENERAL COMPLIANCE WITH THE INFORMATION CONTAINED IN THE CONTRACT DOCUMENTS. COMMENTS REGARDING THESE SUBMITTALS DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PERFORMING HIS WORK IN A SAFE AND SATISFACTORY MANNER. IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY 350. CONCRETE/MASONRY ANCHORS 350.1 ALL ADHESIVE FOR ANCHORING TO CONCRETE SHALL BE "HILTI HIT-HY 200 ADHESIVE ANCHORS" AS MANUFACTURED BY HILTI FASTENING SYSTEMS, INC. (OR APPROVED EQUIVALENT). 350.2 ALL ADHESIVE ANCHORS FOR ANCHORING TO GROUT -FILLED MASONRY SHALL BE "HILTI HIT-HY 70 ADHESIVE ANCHORS" AS MANUFACTURED BY HILTI FASTENING SYSTEMS, INC. (OR EQUAL). 350.3 THE SPACING AND MINIMUM EMBEDMENT OF POST -INSTALLED ANCHORS SHALL BE AS INDICATED ON DRAWINGS. THE INSTALLATION OF THE ANCHORS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED PROCEDURES. 420. MASONRY 420.1 ALL MASONRY WORK SHALL BE IN CONFORMANCE WITH THE LATEST EDITION OF "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (TMS 402/ACI 530/ASCE 5) AND THE "SPECIFICATIONS FOR MASONRY STRUCTURES" (TMS 602/ACI 530.1/ASCE 6) OF THE MASONRY SOCIETY. 420.2 ALL MASONRY WORK TO BE EXECUTED IN COLD WEATHER SHALL BE IN CONFORMANCE WITH THE RECOMMENDATIONS FOR COLD WEATHER CONSTRUCTION OF THE LATEST EDITION OF "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (TMS 402/ACI 530/ASCE 5) AND THE "SPECIFICATIONS FOR MASONRY STRUCTURES" (TMS 602/ACI 530.1/ASCE 6) OF THE MASONRY SOCIETY WITH THE FOLLOWING ADDITION TO THE REQUIREMENTS OF TMS 602/ACI 530.1/ASCE 6, SECTION 1.8-C: FOR ALL CONDITIONS WHEN TEMPERATURES FALL BELOW 40 DEGREES F, THE TEMPERATURE OF THE NEWLY LAID MASONRY OR NEWLY GROUTED MASONRY SHALL BE MAINTAINED ABOVE 32 DEGREES (F) FOR A MINIMUM OF 24 HOURS USING THE METHODS DESCRIBED IN TMS 602/ACI 530.1/ASCE 6. 420.3 MORTAR SHALL CONFORM TO THE PROPORTION SPECIFICATION OF ASTM C270, TYPE M OR S. PROVIDE TYPE M MORTAR AT ALL HIGH STRENGTH MASONRY NOTED AS F'm = 2500 PSI OR GREATER. PROVIDE TYPE S MORTAR AT ALL STRUCTURAL MASONRY AND REINFORCED MASONRY UNLESS NOTED OTHERWISE. 420.4 GROUT SHALL CONFORM TO ASTM C476 AND AS FOLLOWS: A. COMPRESSIVE STRENGTH (F'c) OF GROUT = F'm AS INDICATED BUT NO LESS THAN 3,000 PSI. B. SLUMP OF GROUT SHALL BE 8 TO 11 INCHES AS MEASURED ACCORDING TO ASTM C143. C. MAX. AGGREGATE SIZE SHALL BE 3/8" (AGGREGATE GRADED TO PRODUCE FINE GROUT IN CONFORMANCE WITH ASTM C476 AND C404). 420.5 LIMIT CEMENTITIOUS MATERIALS IN MORTAR TO: PORTLAND CEMENT CONFORMING TO ASTM C150 TYPE I; LIME CONFORMING TO ASTM C207; AND MORTAR CEMENT CONFORMING TO ASTM C1329. 420.6 PROVIDE SOLID AND HOLLOW LOAD BEARING CONCRETE BLOCK UNITS CONFORMING TO ASTM C90. FURNISH CONCRETE BLOCK WITH NET AREA COMPRESSIVE STRENGTH [AS SPECIFIED BY TABLE 2 OF TMS 602/ACI 530.1/ASCE 6, SECTION 1.4 B.2 BASED ON THE UNIT STRENGTH METHOD. 420.7 MINIMUM 28 -DAY ULTIMATE COMPRESSIVE STRENGTH OF MASONRY A. F'm 1500 PSI 420.8 HORIZONTAL JOINT REINFORCING FOR ALL EXTERIOR AND LOAD BEARING WALLS SHALL BE GALVANIZED LADDER TYPE DUR-O-WAL, OR EQUIVALENT AS APPROVED BY THE ENGINEER WITH 2-9 GAUGE LONGITUDINAL WIRE AND 9 GAUGE CROSS WIRE, SPACED AT 16" CENTER TO CENTER, UNLESS NOTED OTHERWISE. PROVIDE ADDITIONAL LAYERS OF JOINT REINFORCEMENT IN THE FIRST TWO COURSES ABOVE AND BELOW A MASONRY OPENING. PROVIDE LAP AS RECOMMENDED BY MANUFACTURER WITH A MINIMUM OF 6". DISCONTINUE JOINT REINFORCING AT CONTROL JOINTS. PROVIDE "L" SHAPE AND "T" SHAPE DUR-O-WAL AT ALL INTERSECTION CORNERS WITH 8" MINIMUM LAP. SEE TYPICAL DETAILS. 420.9 FULL BED AND HEAD JOINTS SHALL BE USED. 420.10 ALL MASONRY WALLS SHALL BE SECURELY BRACED UNTIL FLOOR OR ROOF SYSTEM HAS BEEN INSTALLED AND HAS BECOME CAPABLE OF STABILIZING THE WALLS. 420.11 GROUT SOLID ALL CELLS IN MASONRY UNITS INSTALLED BELOW GRADE. 420.12 GROUT SOLID ALL CELLS CONTAINING REINFORCING, AND WHERE INDICATED ON PLANS AND SECTIONS. 420.13 PROVIDE FINE GROUT PER ASTM C476 WHEN WIDTH OF GROUT SPACE IS LESS THAN 2". PROVIDE COARSE GROUT FOR GROUT SPACE WIDTHS 2" OR GREATER. PROVIDE FINE GROUT WHEN REINFORCING HAS LESS THAN 1/2" CLEARANCE. 420.14 DEFORMED BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60. PROVIDE LAP SPLICES OF 72 BAR DIAMETERS MINIMUM UNLESS 40 BAR DIAMETERS IS PERMITTED PER TYPICAL DETAILS OR SECTIONS. PROVIDE BAR SPACERS AS REQUIRED TO PROPERLY LOCATE REINFORCING. 420.15 MASONRY COURSING SHOWN IN SECTION IS APPROXIMATE. REFER TO PLANS AND ELEVATIONS FOR ACTUAL COURSING. COORDINATE ACTUAL COURSING REQUIREMENTS WITH ARCHITECTURAL DRAWINGS. `I ATLANTIC ENGINEERING 6501 Arlington Expressway Building B, Suite 201 Jacksonville, FL 32211 PH: 904.743.4633 FX:904.725.9295 FL GOA #791 SC COA #1691 AES #317-193 DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: DRAWN BY: SCD S1.1 00 W cj� rn }+ U LLJ N O 0 W �QQ J Q W U w L Z m _U W LO F- Q W N N M Q CU c E Z Q o o � LL N Z Q Q J O m U CUcc CD aM CDL M W Q LL Q J •� c c o U o Y V m cfl C=) N ll� E M N ~_ a) •� N O U) O s � Z o M CO L � a> C c ti rn > rn rn �t � N M rn W M l- DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: DRAWN BY: SCD S1.1 M M W cj� N N co O LLJ ILL Z U J Q W U w Z m _U W LU LU F- Q W �Q Q Q � Q � Z Q Z w J Q Z Q Q J O m _U F aM LUQ W Q LL Q J o U DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: DRAWN BY: SCD S1.1 EXISTI EXISTI BEAM EXIS' EXIS' EXISTII FOOTII L -- SECTION 101 SCALE: 3/4" = V-0" S2.1 GROUT REINFORCED CELLS TIGH' TO BOTTOM OF EXISTING CONCRI BEAM BY REMOVING PORTION OF FACESHELL AND EXTENDING FRO ABOVE OPENING. TRIM EXCESS CONCRETE AND DRYPACK VOIDS NECESSARY. #5 DOWEL DRILLED AND ADHESIVE ANCHORED WITH 5" EMBED INTO EXISTING CONCRETE BEAM. USE ADHESIVE SYSTEM AND COMPONENTS SUITABLE FOR OVERHEAD APPLICATION. #5 VERT CENTERED IN END CELL EACH SIDE OF NEW OPENING. FILL CELLS SOLID WITH 3000 PSI GROUT #5 DOWEL DRILLED AND ADHESIVE ANCHORED WITH 5" EMBED INTO EXISTING SLAB ^"'^,RETE SLAB SECTION 104 SCALE: 3/4" =1'-0" S2.1 FING ;RETE SLAB .AND EPDXY #3 DOWELS i" OC WITH 4" EMBED JAPOR RETARDER EXISTI EXISTI BEAM WINDOW SEE ARCH #5 SILL REINF EXTEND 8" PAST EACH SIDE OF NEW OPENING EXISTING CMU — #5 DOWEL DRILLED AND EXISTING SLAB \� ADHESIVE ANCHORED WITH 5" EMBED INTO EXISTING SLAB BELOW MIDDLE OF NEW Y WINDOW OPENING EXISTING CONCRETE FOOTING SECTION 102 SCALE: 3/4" = 1'-0" S2.1 IFI SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY EXISTING ROOF FRAMING EXISTING CONCRETE BEAM EXISTIN EXISTING FOOTING SECTION 103 SCALE: 3/4"= 1'-0" S2.1 DOOR SEE ARCH REMOVE EXISTING CMU AS REQUIRED TO POUR SIDEWALK SLAB OVER EXISTING CMU. FILL UNGROUTED CMU CELLS BELOW NEW DOOR OPENING SOLID WITH 3000 PSI GROUT EXISTING CMU ATLANTIC ENGINEERING 6501 Arlington Expressway Building B, Suite 201 Jacksonville, FL 32211 PH: 904.743.4633 FX:904.725.9295 FL COA #791 SC COA #1691 AES #317-193 \1....... ' Q.• .E IV -. `* • O 471 *% ; � 1 x ��0 :•••• TATE ; `��`� P•• �•OR -�--� U ATLANTIC ENGINEERING 6501 Arlington Expressway Building B, Suite 201 Jacksonville, FL 32211 PH: 904.743.4633 FX:904.725.9295 FL COA #791 SC COA #1691 AES #317-193 DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: DRAWN BY: SCD S2.1 M M N N m L.0 F-- J u_ I LU C.0 00 -�--� U U rn N 0 cq 0 0 Z U L z O LO Q J Q N N Q M W cu 0 o c O U QO m ccLam_ . -CN c U t m L a) cv o a> o N M O Y v cv N E � M u") ~ N CD 0C) CO m Z o O CU co L V W c r+ rn > � CD V- C- N M CD r r O � W M� DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: DRAWN BY: SCD S2.1 M M N N m L.0 F-- J u_ LU U U w cq CO Z U z O LLLJ � Q J Q W Z W c 0 J QO m J U F- U -1 F- Z J J LL Q M O DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: DRAWN BY: SCD S2.1 0 TOILET O 4 FEll TOILET A/C :A/C] � STOCKROOM Eli DISPLAY EXISTING FLOOR PLAN SCALE: 1 /4" = 1'-0" • 0 F SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY m 4 E 0 2' 4' 8' SCALE: 1/4" = 1' PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: •B AD2ml `o co �� U rn N 0 4�CD W 0 a Z= LSI (.5 J U w a Lo m � N N 0 M 0 ca 0 J O 0 u— O U LL L U U L ca (' Z - cu � Z J O t/) o N Y m i U CB LJJ w Lu z Q � CO N u') E co N M O L3 a) '� _~ N O O L m Z 0 O X cu a ti > � Q � N M V CD W� M PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: •B AD2ml M M N N M Z W LL a Z= LSI (.5 J U w a � m � Z 0 wQ 0 �¢ J Q LL (D� Z - w � Z J O t/) m J LJJ w Lu z Q --j L.L. ~ Q M O PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: •B AD2ml EXISTING ILLUMINATED EMERGENCY EXIT SIGN TO REMAIN REMOVE EXISTING SURFACE -MOUNTED LIGHT FIXTURE (ABOVE) AND PREP FOR NEW LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS I EXISTING A/C EXTERIOR A/C CONDENSING UNIT TO REMAIN, TYPICAL m DIMENSION TO BE TAKEN FROM EDGE OF EXISTING CMU PILASTER - DESIGN INTENT IS TO ALIGN NEW MASONRY OPENINGS WITH EXISTING CMU JOINTS; ADJUST AS REQUIRED. t7i2 i V -o „ REMOVE EXISTING CABINET, SHELVES, TOILET ACCESSORIES, AND FLOOR AND WALL FINISHES - PREP FLOORS AND WALLS FOR NEW FINISHES REMOVE AND REINSTALL EXISTING GRAB BARS SO TOP OF GRAB BAR IS 36" A.F.F. REMOVE EXISTING ELECTRIC WALTER COOLER AND PREP WATER AND SANITARY FOR NEW HIGH -LOW COMBINATI JN ELECTRIC WATER COOLER - SEE w PLUMBING DRAWINGS • DISPLAY 1 4 p U ° REMOVE AND RELOCATE TOILET EXISTING DOOR & FRAME TO NEW IT/ELEC 112 JL O� REMOVE ALL EXISTING PLUMBING FIXTURES IN II I TOILET ROOM - CAP I I PLUMBING IN WALL AND BELOW FLOOR AS REQUIRED II STOCKROOM �- EXISTING WALL TO BE REMOVED, TYPICAL 1. REMOVE ALL EXISTING MERCHANDISING EQUIPMENT, CABINETS, FURNITURE, DISPLAY RACKS, ETC. 2. REMOVE ALL EXISTING ACOUSTICAL TILE CEILINGS. 3. REMOVE ALL EXISTING FLOOR FINISHES. 4. REMOVE ALL EXISTING FRP WALL PANELS FROM WALLS INDICATED TO REMAIN. SELECTIVELY DEMO PO TION OF EXISTING WALL FOR NEW ALUMINUM -FRAMED STOREFRONT WINDOW, TYPICAL - SEE EXTERIOR ELEVATION 3/AD3.1 EXISTNG STEEL PIPE COLUMN, TYPICAL EXISTING COUNTERTOP AND CABINETS TO BE REMOVED 1 ro] EXISTNG STEEL PIPE COLUMN WITH 8" X 8" BASE PLATE, TYPICAL SELECTIVELY DEMO PORTION OF EXISTING WALL FOR NEW ALUMINUM -FRAMED STOREFRONT AND ENTRANCE DOOR - SEE EXTERIOR ELEVATION 1/AD3.1 REMOVE EXISTING CONCRETE WALKWAY WHERE HATCHED 1 SELECTIVE DEMOLITION PLAN SCALE: 1/4" = V-0" -7 31a„ t5- --- 3'4' 6'-8" 4'-0"----- L — — — — '-0"-L---- -----J EXISTING WALL TO REMAIN, TYPICAL EXISTING ALUMINUM -FRAMED STOREFRONT TO REMAIN, TYPICAL EXISTING MONUMENT SIGN TO BE REMOVED 0 2' 4' 8' SCALE: 1/4" = 1' IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY L SELECTIVE DEMOLITION GENERAL NOTES A. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION. B. IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN THE WORK; HOWEVER, IF HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ARCHITECT AND LANDLORD. C. VERIFY THAT EXISTING UTILITIES HAVE BEEN SHUT OFF PRIOR TO STARTING SELECTIVE DEMOLITION OPERATIONS. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. D. EXISTING WARRANTIES: REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND SURFACES CUT OR DAMAGED DURING SELECTIVE DEMOLITION, BY METHODS AND WITH MATERIALS AND USING APPROVED CONTRACTORS SO AS NOT TO AVOID EXISITING WARRANTIES. NOTIFY WARRANTOR BEFORE PROCEEDING. VERIFY EXISTING WARRANTED SYSTEMS WITH LANDLORD PRIOR TO SELECTIVE DEMOLITION. E. EXISTING HVAC AIR HANDLERS AND EXTERIOR CONDENSING UNITS SHALL REMAIN AND MUST BE PROTECTED AGAINST DAMAGE FROM SELECTIVE DEMOLITION OPERATIONS. F. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION AS REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO ADJACENT BUILDINGS AND FACILITIES TO REMAIN. G. PROVIDE PROTECTION TO INSURE SAFE PASSAGE OF PEOPLE AROUND SELECTIVE DEMOLITION AREA. H. PROVIDE TEMPORARY WEATHER PROTECTION, DURING INTERVAL BETWEEN SELECTIVE DEMOLITION OF EXISTING CONSTRUCTION ON EXTERIOR SURFACES AND NEW CONSTRUCTION, TO PREVENT WATER LEAKAGE AND DAMAGE TO STRUCTURE AND INTERIOR AREAS. I. PROTECT WALLS, CEILINGS, FLOORS AND OTHER EXISTING FINISHES THAT ARE TO REMAIN OR THAT ARE EXPOSED DURING THE SELECTIVE DEMOLITION PROCESS. J. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND AS REQUIRED: J.A. PROCEED WITH SELECTIVE DEMOLITION SYSTEMATICALLY, FROM HIGHER TO LOWER LEVEL. J.B. NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE, AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION. USE HAND TOOLS OR SMALL POWER TOOLS DESIGNED FOR SAWING OR GRINDING, NOT HAMMERING OR CHOPPING. TEMPORARILY COVER OPENINGS TO REMAIN. J.C. REMOVE DECAYED, VERMIN -INFESTED, OR OTHERWISE UNSUITABLE MATERIALS AND PROMPTLY DISPOSE OFF-SITE. J.D. REMOVE SELECTIVE DEMOLITION MATERIALS AND LOWER TO GROUND BY METHOD SUITABLE TO AVOID FREE FALL AND TO PREVENT GROUND IMPACT OR DUST GENERATION. J.E. LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND MATERIALS SO AS NOT TO IMPOSE EXCESSIVE LOADS ON SUPPORTING WALLS, FLOORS, OR FRAMING. J.F. DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY. DO NOT ALLOW THEM TO ACCUMULATE ON-SITE. COMPLY WITH HAULING AND DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION. K. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT. PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED. L. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. M. SELECTIVE DEMOLITION FOR CONCRETE SLABS ON GRADE: SAW -CUT PERIMETER OF AREA TO BE DEMOLISHED, AND THEN BREAK UP AND REMOVE. N. SELECTIVE DEMOLITION FOR MASONRY: DEMOLISH IN SMALL SECTIONS. CUT MASONRY AT JUNCTURES WITH CONSTRUCTION TO REMAIN, USING POWER -DRIVEN SAW, AND THEN REMOVE MASONRY BETWEEN SAW CUTS. 0. SELECTIVE DEMOLITION FOR RESILIENT FLOOR COVERINGS: REMOVE FLOOR COVERINGS AND ADHESIVE ACCORDING TO RECOMMENDATIONS IN RFCI'S RECOMMENDED WORK PRACTICES FOR THE REMOVAL OF RESILIENT FLOOR COVERINGS. I t!� 0 `00 �--+ U m N 0 J W 0 CL z= Z LLJ U U w L N m � N J co a O m E 0 u- 0 ui W � o cc L a) m L W Z w J W _ O o m U a Y U m m co �N � M N ti CD -,:r O CD Z 0X o m CD = CD a, a, Q N M c- cD 0 WC -0 M °' � Z M M N Q J W _j E' CL z= Z LLJ U U w 0 (D m � Z J Y a O � W � o 0 (D< W Z w J Z O Q —j m U W wz J W wQ LL_a 0 It PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB i AD2m2 o C) �v L_ � r PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB i AD2m2 EXISTING ALUMINUM GUARDRAIL, TYPICAL EL +10'-0" TOP OF MASONRY OPENING EL +2'-0" EXISTING WALL -MOUNTED LIGHT FIXTURE, TYPICAL BOTT. OF MASONRY OPENING EXISTING WEST ELEVATION SCALE: 1 /4" = V-0" EXISTING "RADIO SHACK" SIGN TO BE REMOVED REMOVE EXISTING DOOR CLOSERS, PUSH BAR PULL HANDLE AND ADHESIVE -APPLIED STREET ADDRESS FROM ENTRANCE DOOR AND PATCH & REPAIR DOOR AND FRAME AS REQUIRED. NOTE: ENTRANCE DOOR TO REMAIN OPERATIO AL UNTIL NEW ALUMINUM -FRAMED ENTRANCE DO R AND SIDELIGHT ARE INSTALLED ON WEST ELE ATION EXISTING ALUMINUM -FRAMED STOREFRONT, TYPICAL EXISTING SOUTH ELEVATION SCALE: 1 /4" = V-0" ILIA J Lll��LIILIIYI EQ _ EQ.�_ (VER FY) -- - -- f YI i SELECTIVELY DEMO PORTION OF EXISTING WALL TO PROVIDE MASONRY OPENING FOR NEW ALUMINUM -FRAMED STOREFRONT WINDOW, TYPICAL EXISTING EAST ELEVATION SCALE: 1 /4" = V-0" 0 EXISTING MONUMENT SIGN TO BE REMOVED REMOVE EXISTING WALL -MOUNTED LIGHT FIXTURE REMOVE PORTION OF EXISTING TRIM TO ACCOMMODATE WIDTH OF NEW AWNING (BY OTHERS) EL +10'-0" TOP OF MASONRY OPENING SELECTIVELY DEMO PORTION OF EXISTING WALL TO PROVIDE MASONRY OPENING FOR NEW ALUMINUM -FRAMED STOREFRONT AND ENTRANCE DOOR ---- - REMOVED EXISTING POWER TO MONUMENT SIGN EXISTING HOLLOW METAL DOOR & FRAME 0 2' 4' 8' SCALE: 1/4" = 1' C/) F — — __:-i L— — — — --- — It— - — — — — — 1 — — — — — —— --- r/ W m REMOVE EXISTING DOOR CLOSERS, PUSH BAR PULL HANDLE AND ADHESIVE -APPLIED STREET ADDRESS FROM ENTRANCE DOOR AND PATCH & REPAIR DOOR AND FRAME AS REQUIRED. NOTE: ENTRANCE DOOR TO REMAIN OPERATIO AL UNTIL NEW ALUMINUM -FRAMED ENTRANCE DO R AND SIDELIGHT ARE INSTALLED ON WEST ELE ATION EXISTING ALUMINUM -FRAMED STOREFRONT, TYPICAL EXISTING SOUTH ELEVATION SCALE: 1 /4" = V-0" ILIA J Lll��LIILIIYI EQ _ EQ.�_ (VER FY) -- - -- f YI i SELECTIVELY DEMO PORTION OF EXISTING WALL TO PROVIDE MASONRY OPENING FOR NEW ALUMINUM -FRAMED STOREFRONT WINDOW, TYPICAL EXISTING EAST ELEVATION SCALE: 1 /4" = V-0" 0 EXISTING MONUMENT SIGN TO BE REMOVED REMOVE EXISTING WALL -MOUNTED LIGHT FIXTURE REMOVE PORTION OF EXISTING TRIM TO ACCOMMODATE WIDTH OF NEW AWNING (BY OTHERS) EL +10'-0" TOP OF MASONRY OPENING SELECTIVELY DEMO PORTION OF EXISTING WALL TO PROVIDE MASONRY OPENING FOR NEW ALUMINUM -FRAMED STOREFRONT AND ENTRANCE DOOR ---- - REMOVED EXISTING POWER TO MONUMENT SIGN EXISTING HOLLOW METAL DOOR & FRAME 0 2' 4' 8' SCALE: 1/4" = 1' C/) 00 00 r/ W m -�-� U UJ N O 0 J� 0Lij � Z m U WWY� �J W Q Q W��0 -0 Q w H— WWQm N N -1 J H M U WWwQ� m .ocu J Q 0 U m cu o N Y U O N L0 M N r-.: L � N _ C) O 0 m X co z=3 o = > a, N M d' O W MF_ IF SHEET IS LESS THAN 22" X 34"', IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY I PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD3ml M M N N r/ W co J , o_zz= H- 0 UJ U w J� 0Lij � Z m U WWY� �J W Q Q W��0 -0 Q w H— WWQm p -1 J H -' U WWwQ� W LL. J Q M 0 Itt IF SHEET IS LESS THAN 22" X 34"', IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY I PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD3ml m IF SHEET IS LESS THAN 22" X 34"', IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY I PROJECT NO. 17032 ISSUE DATE: 06/28/17 REVISIONS: DRAWN BY: SAB AD3ml 0 REMOVE AND REPLACE SLAB TO INSTALL NEW PLUMBING COORDINATE LOCATIONS WITH ARCH AND PLUMBING SEE 104/S2.1 13 101 S2.1 r��% SLAB PLAN ko� SCALE: 1/4" = V-0" 102 101 S2.1 EXISTING STEEL COLUMN TO CUT OFF IEW WINDOW OPENING AND FILLED WITH GROUT H GENERALNOTES 100. DESIGN CRITERIA 100.1 DESIGN BUILDING CODE: A. FLORIDA BUILDING CODE, 2014 100.2 GRAVITY LOADS: A. ROOF LIVE LOADS: 1. FLAT ROOF 20 PSF 100.3 LATERAL LOADS: A. WIND LOADS (IN ACCORDANCE WITH DESIGN BUILDING CODE PER GENERAL NOTE 100.1): 1. ULTIMATE DESIGN WIND SPEED (3 SECOND GUST), Vult = 129 MPH 2. NOMINAL DESIGN WIND SPEED (3 SECOND GUST), Vasd = 100 MPH 3. RISK CATEGORY = II 4. EXPOSURE CATEGORY = C 5. ENCLOSURE CLASSIFICATION = ENCLOSED 6. INTERNAL PRESSURE COEFFICIENT (GCpi) = +/-0.18 7. WALL COMPONENTS AND CLADDING PRESSURES, Pult = +/- 47 PSF 110. GENERAL 110.1 THESE DRAWINGS HAVE BEEN PRODUCED ENTIRELY ON ATLANTIC ENGINEERING SERVICES CADD SYSTEM. ANY OTHER LETTERING, LINES OR SYMBOLS, OTHER THAN PROFESSIONAL STAMPS AND SIGNATURES, HAVE BEEN MADE WITHOUT THE AUTHORIZATION OF ATLANTIC ENGINEERING SERVICES AND ARE INVALID. 110.2 THE STRUCTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL STRUCTURAL FEATURES, UNLESS NOTED OTHERWISE. THE ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL DIMENSIONS. 110.3 DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. ONLY DIMENSIONS INDICATED ON DRAWINGS MAY BE USED TO ESTABLISH THE LOCATION AND EXTENT OF STRUCTURAL WORK. IF A REQUIRED DIMENSION IS NOT FURNISHED ON DRAWINGS, THE CONTRACTOR SHALL SUBMIT A REQUEST FOR INFORMATION TO OBTAIN THE DIMENSION. 110.4 THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ETC., AND SHALL NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES, ADDITIONAL INFORMATION, ETC., BEFORE BEGINNING THE WORK. 110.5 THE CONTRACTOR SHALL USE EXTREME CAUTION IN THE DEMOLITION OF EXISTING STRUCTURES. SUCH DEMOLITION SHALL BE PERFORMED IN SUCH A MANNER AS TO MAINTAIN THE STRUCTURAL INTEGRITY OF ALL EXISTING STRUCTURES TO REMAIN. PROVIDE SHORING AS REQUIRED. 110.6 ALL STRUCTURAL WORK SHALL BE INSPECTED IN ACCORDANCE WITH THE BUILDING CODE AND ALL LOCAL ORDINANCES. THE OWNER SHALL ENGAGE AN EXPERIENCED, QUALIFIED TESTING/INSPECTION AGENCY, SUBJECT TO THE REVIEW OF THE ARCHITECT, TO PERFORM ALL INSPECTION WORK, AS REQUIRED. 120, SHOP DRAWINGS 120.1 THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW BY ATLANTIC ENGINEERING SERVICES AND THE PROJECT ARCHITECT. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL COMPONENTS INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING: A. REINFORCING STEEL FOR CONCRETE AND MASONRY B. CONCRETE GROUT MIX DESIGN C. CONCRETE AND/OR MASONRY POST -INSTALLED ANCHORS 120.2 SHOP DRAWINGS TO BE SUBMITTED SHALL PROVIDE COMPLETE INFORMATION FOR THE PRODUCTS OR COMPONENTS TO BE SUPPLIED. SUBMITTAL INFORMATION SHALL INCLUDE, BUT NOT BE LIMITED TO: MEMBER SIZES AND DIMENSIONS; GRADES OF MATERIAL FURNISHED; MATERIAL PREPARATION REQUIRED; MATERIAL FINISH AND MATERIAL COATINGS TO BE FURNISHED; INFORMATION REGARDING CUTS, COPES, AND HOLES REQUIRED FOR OTHER TRADES; END CONNECTIONS; CAMBER AND OTHER DEVIATION FROM LINE; SPECIAL ERECTION AND/OR INSTALLATION PROCEDURES, INCLUDING REQUIREMENTS FOR TEMPORARY STABILIZATION. 120.3 ALL SHOP DRAWING RESUBMITTALS AND RECORD COPY SUBMITTALS SHALL HAVE ALL REVISIONS SUBSEQUENT TO THE PREVIOUS SUBMISSION CLOUDED OR OTHERWISE IDENTIFIED ON THE RESUBMITTED SHEETS. RESUBMITTALS AND RECORD COPY SUBMITTALS WITHOUT IDENTIFICATION OF REVISIONS WILL BE REJECTED WITHOUT REVIEW. 120.4 THE CONTRACTOR SHALL NOT DIRECTLY INCORPORATE THE STRUCTURAL DRAWINGS, OR PORTIONS THEREOF, INTO SHOP DRAWINGS OR ERECTION DRAWINGS TO BE SUBMITTED FOR THIS PROJECT WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION OF ATLANTIC ENGINEERING SERVICES. SUBMITTED SHOP DRAWINGS WHICH CONTAIN COPIES OR REPRODUCTIONS OF ANY PORTION OF THE STRUCTURAL DRAWINGS WITHOUT THE EXPRESS WRITTEN PERMISSION OF ATLANTIC ENGINEERING SERVICES WILL BE RETURNED REJECTED. PERMISSION FOR A SPECIFIC CONTRACTOR OR SUB -CONTRACTOR TO USE PORTIONS OF THE STRUCTURAL DRAWINGS IN THEIR PREPARATION OF SHOP DRAWINGS REQUIRES THAT CONTRACTOR OR SUB -CONTRACTOR TO ENTER INTO A WRITTEN AGREEMENT WITH ATLANTIC ENGINEERING SERVICES AND TO PAY A SERVICE FEE. SUCH AGREEMENT IS NON-TRANSFERRABLE AND IS EXTENDED ONLY TO THAT CONTRACTOR FOR THE DURATION OF THIS PROJECT. 120.5 THE CONTRACTOR SHALL SUBMIT ELECTRONIC COPIES OF SHOP DRAWINGS IN LIEU OF PRINTED COPIES. COPIES SHALL BE SUBMITTED TO ATLANTIC ENGINEERING SERVICES IN PDF FILE FORMAT (ISO 32000-1), WITH ONE (1) ELECTRONIC FILE PER SUBMISSION. ATLANTIC ENGINEERING SERVICES WILL REVIEW, ANNOTATE, AND RETURN ONE (1) FILE TO THE ARCHITECT FOR THEIR REVIEW AND DISTRIBUTION TO THE CONTRACTOR. 120.6 THE REVIEW OF SHOP DRAWINGS AND OTHER SUBMITTALS FOR THIS PROJECT IS FOR CONFORMANCE WITH THE DESIGN CONCEPT AND FOR GENERAL COMPLIANCE WITH THE INFORMATION CONTAINED IN THE CONTRACT DOCUMENTS. COMMENTS REGARDING THESE SUBMITTALS DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PERFORMING HIS WORK IN A SAFE AND SATISFACTORY MANNER. IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY 350. CONCRETE/MASONRY ANCHORS 350.1 ALL ADHESIVE FOR ANCHORING TO CONCRETE SHALL BE "HILTI HIT-HY 200 ADHESIVE ANCHORS" AS MANUFACTURED BY HILTI FASTENING SYSTEMS, INC. (OR APPROVED EQUIVALENT). 350.2 ALL ADHESIVE ANCHORS FOR ANCHORING TO GROUT -FILLED MASONRY SHALL BE "HILTI HIT-HY 70 ADHESIVE ANCHORS" AS MANUFACTURED BY HILTI FASTENING SYSTEMS, INC. (OR EQUAL). 350.3 THE SPACING AND MINIMUM EMBEDMENT OF POST -INSTALLED ANCHORS SHALL BE AS INDICATED ON DRAWINGS. THE INSTALLATION OF THE ANCHORS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED PROCEDURES. 420. MASONRY 420.1 ALL MASONRY WORK SHALL BE IN CONFORMANCE WITH THE LATEST EDITION OF "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (TMS 402/ACI 530/ASCE 5) AND THE "SPECIFICATIONS FOR MASONRY STRUCTURES" (TMS 602/ACI 530.1/ASCE 6) OF THE MASONRY SOCIETY. 420.2 ALL MASONRY WORK TO BE EXECUTED IN COLD WEATHER SHALL BE IN CONFORMANCE WITH THE RECOMMENDATIONS FOR COLD WEATHER CONSTRUCTION OF THE LATEST EDITION OF "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (TMS 402/ACI 530/ASCE 5) AND THE "SPECIFICATIONS FOR MASONRY STRUCTURES" (TMS 602/ACI 530.1/ASCE 6) OF THE MASONRY SOCIETY WITH THE FOLLOWING ADDITION TO THE REQUIREMENTS OF TMS 602/ACI 530.1/ASCE 6, SECTION 1.8-C: FOR ALL CONDITIONS WHEN TEMPERATURES FALL BELOW 40 DEGREES F, THE TEMPERATURE OF THE NEWLY LAID MASONRY OR NEWLY GROUTED MASONRY SHALL BE MAINTAINED ABOVE 32 DEGREES (F) FOR A MINIMUM OF 24 HOURS USING THE METHODS DESCRIBED IN TMS 602/ACI 530.1/ASCE 6. 420.3 MORTAR SHALL CONFORM TO THE PROPORTION SPECIFICATION OF ASTM C270, TYPE M OR S. PROVIDE TYPE M MORTAR AT ALL HIGH STRENGTH MASONRY NOTED AS F'm = 2500 PSI OR GREATER. PROVIDE TYPE S MORTAR AT ALL STRUCTURAL MASONRY AND REINFORCED MASONRY UNLESS NOTED OTHERWISE. 420.4 GROUT SHALL CONFORM TO ASTM C476 AND AS FOLLOWS: A. COMPRESSIVE STRENGTH (F'c) OF GROUT = F'm AS INDICATED BUT NO LESS THAN 3,000 PSI. B. SLUMP OF GROUT SHALL BE 8 TO 11 INCHES AS MEASURED ACCORDING TO ASTM C143. C. MAX. AGGREGATE SIZE SHALL BE 3/8" (AGGREGATE GRADED TO PRODUCE FINE GROUT IN CONFORMANCE WITH ASTM C476 AND C404). 420.5 LIMIT CEMENTITIOUS MATERIALS IN MORTAR TO: PORTLAND CEMENT CONFORMING TO ASTM C150 TYPE I; LIME CONFORMING TO ASTM C207; AND MORTAR CEMENT CONFORMING TO ASTM C1329. 420.6 PROVIDE SOLID AND HOLLOW LOAD BEARING CONCRETE BLOCK UNITS CONFORMING TO ASTM C90. FURNISH CONCRETE BLOCK WITH NET AREA COMPRESSIVE STRENGTH [AS SPECIFIED BY TABLE 2 OF TMS 602/ACI 530.1/ASCE 6, SECTION 1.4 B.2 BASED ON THE UNIT STRENGTH METHOD. 4201 MINIMUM 28 -DAY ULTIMATE COMPRESSIVE STRENGTH OF MASONRY A. F'm 1500 PSI 420.8 HORIZONTAL JOINT REINFORCING FOR ALL EXTERIOR AND LOAD BEARING WALLS SHALL BE GALVANIZED LADDER TYPE DUR-O-WAL, OR EQUIVALENT AS APPROVED BY THE ENGINEER WITH 2-9 GAUGE LONGITUDINAL WIRE AND 9 GAUGE CROSS WIRE, SPACED AT 16" CENTER TO CENTER, UNLESS NOTED OTHERWISE. PROVIDE ADDITIONAL LAYERS OF JOINT REINFORCEMENT IN THE FIRST TWO COURSES ABOVE AND BELOW A MASONRY OPENING. PROVIDE LAP AS RECOMMENDED BY MANUFACTURER WITH A MINIMUM OF 6". DISCONTINUE JOINT REINFORCING AT CONTROL JOINTS. PROVIDE "L" SHAPE AND "T" SHAPE DUR-O-WAL AT ALL INTERSECTION CORNERS WITH 8" MINIMUM LAP. SEE TYPICAL DETAILS. 420.9 FULL BED AND HEAD JOINTS SHALL BE USED. 420.10 ALL MASONRY WALLS SHALL BE SECURELY BRACED UNTIL FLOOR OR ROOF SYSTEM HAS BEEN INSTALLED AND HAS BECOME CAPABLE OF STABILIZING THE WALLS. 420.11 GROUT SOLID ALL CELLS IN MASONRY UNITS INSTALLED BELOW GRADE. 420.12 GROUT SOLID ALL CELLS CONTAINING REINFORCING, AND WHERE INDICATED ON PLANS AND SECTIONS. 420.13 PROVIDE FINE GROUT PER ASTM C476 WHEN WIDTH OF GROUT SPACE IS LESS THAN 2". PROVIDE COARSE GROUT FOR GROUT SPACE WIDTHS 2" OR GREATER. PROVIDE FINE GROUT WHEN REINFORCING HAS LESS THAN 1/2" CLEARANCE. 420.14 DEFORMED BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60. PROVIDE LAP SPLICES OF 72 BAR DIAMETERS MINIMUM UNLESS 40 BAR DIAMETERS IS PERMITTED PER TYPICAL DETAILS OR SECTIONS. PROVIDE BAR SPACERS AS REQUIRED TO PROPERLY LOCATE REINFORCING. 420.15 MASONRY COURSING SHOWN IN SECTION IS APPROXIMATE. REFER TO PLANS AND ELEVATIONS FOR ACTUAL COURSING. COORDINATE ACTUAL COURSING REQUIREMENTS WITH ARCHITECTURAL DRAWINGS. :aP, � E�S •e� OT % STAT ATLANTIC ENGINEERING 6501 Arlington Expressway Building B, Suite 201 Jacksonville, FL 32211 PH: 904.743.4633 FX:904.725.9295 FL COA #791 SC COA #1691 AES #317-193 CCD M M W rn 4__ U W N 0 ^^ ♦♦ 4 ZLij 0Q Q U w Ur m WF LO U - Z W N N Q M 0 cv v � E Z Q O o U moo LL vi Z Q ZQ J O m ccm U N L w LLI z Q Q � ca _I •� c c a? o C, Y v CU co C=0 N M N ~_ •� N W 0 Z o ) x f° u- a� ( c � rn � CN r N M rn W M I- DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: D' f l,SCD S1.1 M M W N N co O W LUL Z ZLij U U w Ur m WF Z U - Z W LU �Q Q 0 � Z Q Z W J Q Z Q ZQ J O m J U CL w LLI z Q Q L- Q _I o DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: D' f l,SCD S1.1 EXISTI EXISTI BEAM EXIST EXIS- EXISTII FOOTIt SECTION 101 SCALE: 3/4" = 1'-0" S2.1 SECTION 104 SCALE: 3/4" = V-0" S2.1 GROUT REINFORCED CELLS TIGHT TO BOTTOM OF EXISTING CONCRETE BEAM BY REMOVING PORTION F FACESHELL AND EXTENDING F IOM ABOVE OPENING. TRIM EXCES N 0 CONCRETE AND DRYPACK VOI S AS NECESSARY. U #5 DOWEL DRILLED AND ADHESIVE ANCHORED WITH 5" EMBED INTO EXISTING CONCRETE BEAM. USE ADHESIVE SYSTEM AND COMPONENTS SUITABLE FOR OVERHEAD APPLICATION. #5 VERT CENTERED IN END CELL EACH SIDE OF NEW OPENING. FILL CELLS SOLID WITH 3000 PSI GROUT #5 DOWEL DRILLED AND ADHESIVE ANCHORED WITH 5" EMBED INTO EXISTING SLAB CONCRETE SLAB EXISTING CONCRETE SLAB DRILL AND EPDXY #3 DOWELS AT 16" OC WITH 4" EMBED LAP VAPOR RETARDER EXISTI EXISTI BEAM EXISTING CMU EXISTING SLAB EXISTING CONCRETE FOOTING SECTION 102 SCALE: 3/4" = 1'-0" S2.1 WINDOW SEE ARCH #5 SILL REINF EXTEND 8" PAST EACH SIDE OF NEW OPENING #5 DOWEL DRILLED AND ADHESIVE ANCHORED WITH 5" EMBED INTO EXISTING SLAB BELOW MIDDLE OF NEW WINDOW OPENING IF SHEET IS LESS THAN 22" X 34", IT IS A REDUCED PRINT - SCALE REDUCED ACCORDINGLY EXISTI EXISTI BEAM EXIS" EXISTING FOOTING SECTION rl3 SCALE: 3/4" = 1'-0" S2.1 DOOR SEE ARCH REMOVE EXISTING CMU AS REQUIRED TO POUR SIDEWALK SLAB OVER EXISTING CMU. FILL UNGROUTED CMU CELLS BELOW NEW DOOR OPENING SOLID WITH 3000 PSI GROUT EXISTING CMU ATLANTIC ENGINEERING 6501 Arlington Expressway Building 8, Suite 201 Jacksonville, FL 32211 PH: 904.743.4633 FX:904.725.9295 FL COA #791 SC COA #1691 AES #317-193 DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: S2.1 �ENBI: A N CV M C.0 U -' LL N 0 LLJ U 0 O U w L CO Z to N N Z O LLJ Y M Q co v � E o o � MO LL vi Cc ..0 U U < MN I..LJL L J ,a> co F— LLJ � a> LLj J o U- v co co N O M lf) � N L �v •� N O cn � O L O Z o O - aD r-- > > a? � N M � r' r O O W M� DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: S2.1 M M r/ N CV M Lu F- -' LL LLJ U U w cq CO Z U Z O LLJ Y Q J Q Q V W Z Q W J < m J U F— LLJ F- Z LLj J J U- Q M O d' DAVID L WEBB PE 47180 PROJECT NO. 17032 ISSUE DATE: REVISIONS: S2.1