1692 MARITIME OAK DR - FORM BOARD ELEVATION CERT FORM BOARD ELEVATION CERTIFICATE
Date V- 41. 13 Permit Number:
Address: /G �z
All American Surveyors Work Order # /Z 7
Required Slab Elevation on City Approved Site Plan:
y. 4/D
Actual Elevation of Form Board or Grade Stake:
J• LI /
Survey Company:
ALL AMERICAN SURVEYORS OF FLORIDA INC.
3751 San Jose Place, Suite 15
Jacksonville FL 32257 Work Phone: 904-279:0088
Signature of Surveyor:(PartyChief)
UNIVERSAL VV ES Project
No: o. 0910.1 00187.0000
ENGINEERING SCIENCES Report Date: 5/2/2018
Consultants In:Geotechnical Engineering-Environmental Sciences
Geophysical Services-Construction Materials Testing-Threshold Inspection
go Building Inspection-Plan Review-Building Code Administration
5561 Florida Mining Blvd So.,Jacksonville, 32257 - P:904-296-657 - F:904-296-0748
In-Place Density Test Report
Client: Toll Brothers, Inc
UES Technician: Dustin Stoll
160 Cape May Avenue f } � ? d �:. Date Tested: 05/02/2018
1 ..4fL �.�.
Ponte Vedra FL 32081 ' ;. A � lA- +
Project: Atlantic Beach Country Club
Atlantic Beach Country Club,Atlantic Beach, Duval County, FL 32233
Area Tested: LOT 120 RESIDENTAL BLDG PAD Type of Test:
Material: Fill Field: ASTM D-6938 Nuclear Gauge Metho
Reference Datum: 0 =Top of Fill Laboratory: ASTM D1557 Modified Proctor
The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density.
aximum ptimum Field Dry Field Soil De Fill
l
Test Density Moisture Density Moisture Compaction pth Pass
No. Location of Test Range (per (%) (pcf) (%) (%) (inch) or Fail
1 NE CORNER OF PAD 0-1 ft 103.3 14.3 98.8 4.5 96 N/A Pas!
2 NW CORNER OF PAD 0-1 ft 103.3 14.3 99.6 5.1 96 N/A Pas:
3 SE CORNER OF PAD 0-1 ft 103.3 14.3 100.4 6.3 97 N/A Pas!
4 SW CORNER OF PAD 0-1 ft 103.3 14.3 98.4 5.9 95 N/A Pas!
-J n..ra.1 �n4e.n a..A..,:ffn ...nFi.ionl:ol mm�o..i of ...r nl:e,En en.J o..Fi.n.s�of:nn