527 PELICAN KEY - PERMIT RES18-0049GENERAL NOTES 1. CODES USED: 2017 FLORIDA BUILDING CODE, RESIDENTIAL EDITION AND EXISTING BUILDING EDITION, ACI, NDS, APA AND ASCE7-10. 2. THE ALTERATIONS FOUND WITHIN THESE PLANS ARE DESIGNATED LEVEL 2 ALTERATIONS IN COMPLIANCE WITH SECTION 301.1.2 OF THE EXISTING BUILDING CODE. 3. ALL DESIGN, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION OVER THE WORK. 4. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO COMMENCING CONSTRUCTION. 5. DETAILS FOUND WITHIN THESE DRAWINGS SHALL BE ASSUMED TO BE TYPICAL DETAILS FOR THIS JOB ONLY. DETAILS SHALL GOVERN CONSTRUCTION FOR THIS JOB UNLESS NOTED OTHERWISE ON THE PLANS. 6. THE SCOPE OF WORK OF THIS PROJECT IS LIMITED TO THE CHANGES SHOWN ON THESE PLANS, THE SCOPE OF WORK SPECIFICALLY EXCLUDES ANY AND ALL ARCHITECTURAL, WATERPROOFING, MECHANICAL, PLUMBING OR ELECTRICAL WORK. 7. EXISTING STRUCTURES ARE SHOWN ON DRAWINGS FOR CLARITY ONLY. VERIFY ALL EXISTING/NEW ELEVATIONS AND TYPE OF CONSTRUCTION OF THOSE STRUCTURES, AND NOTIFY ENGINEER IMMEDIATELY BEFORE BEGINNING NEW CONSTRUCTION OF ANY INTERFERENCES AND/OR DISCREPANCIES THAT MIGHT EXIST BETWEEN CONSTRUCTION DOCUMENTS AND/OR ACTUAL FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND OTHER SUCH ITEMS OR OTHER MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY PERSONNEL DURING CONSTRUCTION. THE DESIGN ADEQUACY AND SAFETY OF ABOVE ITEMS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. FRAMING NOTES 1. DESIGN OF WOOD COMPONENTS IN THIS STRUCTURE IS BASED ON THE 2017 FLORIDA BUILDING CODE, RESIDENTIAL EDITION AND THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. 2. DESIGN LOADING FOR THIS STRUCTURE IS FOUND IN THE LOAD TABLE ON THIS SHEET. 3. ALL FRAMING ANCHORS SHOWN ON PLANS ARE SIMPSON. ALTERNATE CONNECTORS ARE ACCEPTABLE PROVIDED EQUAL OR GREATER CAPACITIES ARE ACHIEVED. CONTACT ENGINEER OF RECORD IF EQUAL CAPACITIES ARE NOT APPARENT. 4. ALL WOOD DIRECTLY EXPOSED TO CONCRETE, MASONRY OR SOIL SHALL BE PRESSURE TREATED. 5. ALL WOOD DIRECTLY EXPOSED TO WEATHER SHALL BE PRESSURE TREATED. 6. NAILS OR CONNECTORS EXPOSED TO WEATHER SHALL BE GALVANIZED. 7. DIMENSION LUMBER 7.1. ALL MEMBER SIZES GIVEN IN THE DRAWINGS ARE NOMINAL DIMENSIONS 7.2. WHERE POSTS ARE CALLED OUT, HEADERS SHALL BEAR FULLY ON POSTS. 7.3. ALL BEAMS AND JOISTS NOT BEARING ON SUPPORTING MEMBERS SHALL BE FRAMED WITH SIMPSON STRONG -TIE JOIST HANGERS OR EQUAL PER APPROVAL OF THE ENGINEER OF RECORD. THE JOIST HANGERS SHALL BE NAILED WITH NAILS MEETING THE DIAMETER AND LENGTH PER THE DETAILS. 8. ALL NAILS SHALL BE COMMON NAILS, UNLESS OTHERWISE NOTED. NAIL SIZES ARE DEFINED CONCRETE NOTES 1. ALL REINFORCED CONCRETE WORK SHALL BE IN CONFORMANCE WITH ACI 318, LATEST EDITION, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,, AND ACI 301, LATEST EDITION, "SPECIFICATIONS FOR STRUCTURAL CONCRETE". 2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE, (145 PCF /-) ALL CEMENT SHALL CONFORM TO ASTM C150, TYPE 1. MAXIMUM AGGREGATE SIZE SHALL BE 1Y2' INCHES FOR FOUNDATIONS, AND %" FOR ALL SLABS AND SHALL CONFORM TO ASTM ..33. 3. MINIMUM CONCRETE COMPRESSIVE STRENGTH OF ALL CONCRETE IS 3 00 PSI AT 28 DAYS. 4. 4" 3000PS1 CONCRETE SLAB WITH 6X6 W1.4 X W1.4 WWM OR 1/2" FIB RMESH OVER A 6 MIL. VAPOR BARRIER AND TERMITE TREATED SOIL. 5. THE FILL BELOW THE FOUNDATION SHOULD BE FREE OF DEBRIS, ORGANIC MATERIAL, COHESIVE SOILS OR ANY OTHER DELETERIOUS MATERIAL. SOIL MUST BE COMPACTED TO 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY FOR TWO FEET BELOW THE BOTTOM OF THE FOOTING. 6. ALL REINFORCEMENT SHALL BE GRADE 40 DEFORMED BARS CONFOR ING TO ASTM -A615. ALL CONCRETE REINFORCEMENT SHALL BE FABRICATED, INSTALLED, SUPPORTED AND SPACED IN FORMS AND SECURED IN PLACE IN ACCORDANCE WITH ACI 315, "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT". 7. CONTRACTOR SHALL VERIFY DIMENSIONS AND LOCATIONS OF ALL SLOTS, PIPE SLEEVES, ETC., AS REQUIRED FOR MECHANICAL TRADES BEFORE CONCRETE IS PLACED. 8. VERTICAL AND HORIZONTAL REINFORCEMENT WILL BE LAPPED FOR 36 BAR DIAMETERS OR 24", WHICHEVER IS GREATER. 9. CORNER REINFORCEMENT SHALL BE LAPPED 25". 10. REINFORCEMENT SHALL HAVE THE FOLLOWING COVER REQUIREMENTS 10.1. 3" FOR CONCRETE CAST AND PERMANENTLY EXPOSED TO EARTH 10.2. 2" FOR CONCRETE EXPOSED TO EARTH AND WEATHER 10.3. 1 1/2" FOR CONCRETE NOT EXPOSED TO WEATHER OR EARTH FOR THE PRIMARY REINFORCEMENT. 11. ONLY DIMENSIONS FOUND ON THE FOUNDATION PLAN BY ALEXANDER GRACE CONSULTING, INC., SHOULD BE USED FOR FOUNDATION CONSTRUCTION. IF DIMENSIONS CAN NOT BE DETERMINED FROM FOUNDATION PLAN, CONTACT THE ENGINEER OFR CORD. 12. STEM WALL TO BE A MAXIMUM OF SIX (6) COURSES TALL. CONTACT ENGINEER OF RECORD IF STEM WALL WILL EXCEED SIX (6) COURSES IN HEIGHT. 13. WHERE THREADED RODS ARE EMBEDDED 12" INTO STEM WALLS, THE TOP TWO COURSES OF STEM WALL MUST BE FILLED. OVERIFY OR PLACE STUD GROUP UNDER BEAM BEARING. NUMBER OF A STUDS EQUALS THAT OF BEAM PLY, MIN 2 STUDS. FASTEN BEAM TO STUD GROUP WITH (2) MSTA24. FASTEN STUD GROUP TO FOOTING WITH LTT20B. USE 10d NAILS IN ALL HOLES. IF THREADED ROD IS WITHIN 12" OF BEARING, NO LTT20B IS REQUIRED. OPLACE 6x6 POST UNDER BEAM BEARING. FASTEN BEAM TO POSE B WITH (2) MSTA24. FASTEN POST TO FOOTING WITH ABU66. USE Od NAILS IN ALL HOLES. BELOW: 8d = 0. 131 " x 2-1/2" SHEET INDEX 10d = 0.148" x 3" 12d = 0.148" x 3-1/4" S1.01 RENOVATION PLAN AND DETAILS 16d = 0.162" x 3-1/2" 9. WHERE FRAMING DETAILS SHOW FOOTINGS, SEE FOOTING DETAILS ON THE FOUNDATION PLAN AND/OR THE FOOTING DETAILS SHEET. 10. CONVENTIONAL FRAMING LUMBER IS 2x No.2 SYP UNLESS NOTED OTHERWISE. EPDXY NOTES 1. ANCHOR BOLTS, REINFORCING STEEL, THREADED RODS, STAIR HANDRAILS, AND OTHER EMBEDDED STEEL ITEMS SHALL BE SET INTO HARDENED CONCRETE WITH EPDXY OR EPDXY GROUT ONLY WHERE DETAILED ON THE DRAWINGS OR WHERE APPROVED BY THE ENGINEER. 2. MANUFACTURER'S DATA FOR ALL EPDXY AND EPDXY GROUT SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. ACCEPTABLE EPDXY PRODUCTS ARE: HILTI HY150, HILTI HSE2421, SIMPSON STRONG -TIE SET OR APPROVED EQUAL. IN USING THE ABOVE PRODUCTS, FOLLOW STRICTLY THE MANUFACTURER'S SPECIFICATIONS AND DIRECTIONS FOR MIXING AND APPLICATION. HEED ALL LABEL WARNINGS. INSTALL IN ACCORDANCE WITH APPLICABLE SAFETY LAWS. 3. ALL EPDXY AND EPDXY GROUT SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 8,000 PSI AND TENSILE STRENGTH OF 2,300 PSI. 4. ALL HOLES SHALL BE DRILLED WITH A DIAMETER NO LARGER THAN 1/8" GREATER THAN THE DIAMETER OF THE STEEL MEMBER BEING INSTALLED. 5. ALL HOLES SHALL BE CLEANED WITH COMPRESSED AIR AND SHALL BE DRY PRIOR TO INSTALLATION OF EPDXY. HOLES SHALL BE FREE OF ALL DELETERIOUS MATERIAL SUCH AS LAITANCE, DUST, DIRT, AND OIL. 6. CONTRACTOR PERFORMING EPDXY WORK SHALL BE AN APPROVED CONTRACTOR BY THE MANUFACTURER FURNISHING THE EPDXY MATERIALS, AND SHALL HAVE NO LESS THAN FIVE YEARS EXPERIENCE IN THE VARIOUS TYPES OF EPDXY RELATED WORK REQUIRED IN THIS PROJECT. A NOTARIZED CERTIFICATION FROM THE MANUFACTURER ATTESTING TO THE TRAINING SHALL BE SUBMITTED TO THE ENGINEER/ARCHITECT ALONG WITH THE PROPOSAL TO DO THE WORK. LOAD TABLE COMPONENT AND CLADDING ROOF: DESIGN PRESSURES LIVE LOAD: 20.0 PSF DEAD LOAD: 7.0 PSF CEILING: LIVE LOAD: 10.0 PSF LIVE LOAD -STORAGE: 30.0 PSF DEAD LOAD: 5.0 PSF FLOOR: -26.6 LIVE LOAD: 40.0 PSF DEAD LOAD: 10.0 PSF DECK LIVE LOAD: 50.0 PSF WIND LOADS: -27.2 WIND SPEED: 130 MPH EXPOSURE: C IMPORTANCE: 1.0 BUILDING CATEGORY: II ENCLOSED BUILDING: o INTERIOR PRESSURE O COEFFICIENT: 0.18 ROOF PITCH: MATCH EXISTING EFFECTIVE AREA,SF END ZONES, PSF INTERIOR ZONES, PSF 0-20 24.4 -32.0 24.4 -26.6 20-50 22.9 -28.8 22.9 -25.3 50-100 21.6 -27.2 21.6 -24.0 100-200 20.8 -24.4 20.8 -22.9 m Lu o 1'-6" EXISTING FLOOR o TRUSSES z O �\ /Fn --- w z° ---------------------------- (3) 1.75"X11.25" _._--------------------------�- 2.OE LVL _ --------------------------- W --------------------------- _J Q M i----------------------------i Q co EXISTING WOOD 1 FRAMED WALLS_--_---- --- W LL S1.01 ----------------------------r Y O z = Ouj ca �/ U --------------------------- Q N f - Z "' a ----------------------------------------------- ----------------------------- Q H -------------------------------------------------- ------------------------�� Q ADJACENT UNIT - '-'- -----------------------------------------------------------------------------+ ----- ---- -------------------- ------------------------------------- EXISTING FLOOR TRUSSES EXISTING FIRST LEVEL WALL PLAN 1/4" = 1'-0" EXISTING WALL EXISTING FLOOR SYSTEM EXISTING FLOOR SYSTEM AT 24" O.C. H3 AT EACH TRUSS, ALL HOLES FILLED WITH 10d NAILS. 3 -PLY 1.75"X11.25" 2.0E LVL. SECTION 3/4" = 1'-0" 'FICECOY REVIEWED FOR CODE COMPLIA CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIO ' REVIEWED BY: DATES I - N� mCD z c aU T p N p o0 z EXISTING WOOD U g FRAMED WALLS cL CL 0ag O 0 z O U acn o a- O A? E W 8 o Q 00 1 -29 o N c U 0< N U U) � D O COnrn ``x1jillill// .�� \NAYNF I FICq�.,9'Qj2 U) Lu o 1'-6" EXISTING FLOOR o TRUSSES z O �\ /Fn --- w z° ---------------------------- (3) 1.75"X11.25" _._--------------------------�- 2.OE LVL _ --------------------------- W --------------------------- _J Q M i----------------------------i Q co EXISTING WOOD 1 FRAMED WALLS_--_---- --- W LL S1.01 ----------------------------r Y O z = Ouj ca �/ U --------------------------- Q N f - Z "' a ----------------------------------------------- ----------------------------- Q H -------------------------------------------------- ------------------------�� Q ADJACENT UNIT - '-'- -----------------------------------------------------------------------------+ ----- ---- -------------------- ------------------------------------- EXISTING FLOOR TRUSSES EXISTING FIRST LEVEL WALL PLAN 1/4" = 1'-0" EXISTING WALL EXISTING FLOOR SYSTEM EXISTING FLOOR SYSTEM AT 24" O.C. H3 AT EACH TRUSS, ALL HOLES FILLED WITH 10d NAILS. 3 -PLY 1.75"X11.25" 2.0E LVL. SECTION 3/4" = 1'-0" 'FICECOY REVIEWED FOR CODE COMPLIA CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIO ' REVIEWED BY: DATES I - z ^J U) CLQ zQ OLu �- c Oz z Q LW ct U c N� mCD U) C14 c aU T p N p o0 U u.. U_ U mD cL CL 0ag o 0 U Q a z ^J U) CLQ zQ OLu �- c Oz z Q LW ct U c N� mCD U) C14 c aU cn co ca �00 p o0 U u.. U_ U cL 0 LO 04U acn LL L co X m°a A? E W 8 o Q 00 1 -29 o N c U 0< N u IT co 0 O COnrn ``x1jillill// .�� \NAYNF I FICq�.,9'Qj2 O��C�,.•��I G �•:mom No. 59328 •:• STATE OF O.C�•'•.�40RlV'' •' • ���' ....• nigiv Sheet No S1.01