992 OCEAN BLVD - PERMIT RESA17-0025 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATL_ANTIC BEACH,RFL 32233
INSPECTION PHONE LINE`247 5814:
RESIDENTIAL ADDITION - SINGLE OR TWO FAMILY RESIDENTIAL ADDITION
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: RESA17-0025
Description: master bedroom addition
Estimated Value: 65337
Issue Date: 12/15/2017
Expiration Date: 6/13/2018
PROPERTY ADDRESS:
Address: 992 OCEAN BLVD
RE Number: 170240 0000
PROPERTY OWNER:
Name: PHILLIPS MICHAEL D
Address: 992 Ocean Boulevard
ATLANTIC BEACH, FL 32233-5526
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
Phone:
Name: PHILLIPS BUILDERS LLC
Address: 1250 SELVA MARINA CIR QA BARBARA CAROLINE PHILLIPS
ATLANTIC BEACH, FL 32233
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
, sirs, City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
800 Seminole Road c +
Atlantic Beach, Florida 32233-5445 0CC
Phone(904)247-5826 Fax(904)247-5845 1017
h,U14 f E-mail: building-dept@coab.us Date routed: S n
City web-site: http://www.coab.us ~-
APPLICATION REVIEW AND TRACKING (FORM
Property Address: 1 C OLOCL i) &y(,'l • Department review required Yes No
�1 ildin
Applicant: + �� `�� S �j�-Lc (�l ��� LL� nnin &Zor
Tree Administrator
Project: fy) 6t5A-4 kb(bDn OLAI L-� 3,/) 1 u lic6 Works
� ublic Utilities- 1
Public Safety"—=-�
Fire Services
Review fee $ Dept_Signature-
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. ❑Denied. M<ct applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING
Reviewed by: Date:
TREE ADMIN. Second Review: []Approved as revised. ❑Denied. ❑Not applicable
XUBLIC�
WORKS, Comments:
TILITI'ESt,
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017 P�/1r Is �(� lw e, -b
City of Atlantic Beach APPLICATION NUMBER
r t� Building Department - "� _ _ (To be assigned by the Building Department.)
,<R _
800 Seminole Road
Atlantic Beach, Florida 32233-5445 K-1.
Phone 904 )247-5826 • Fax 904 247-$84`�Ea�a� 0 9 L®17
(bui din de t@ coab.us Date routed:
E-mail:
�'•oz 9- p
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: I 0 C(9—CL j) Department review required Yes No
"din
Applicant:
Applicant: �A 1�� 5 )? CL ` (�` LL( nnin &Zon'
p Tree Administrator
Project: V'1'1 CLS -{ bkh M)n 3•/-) � =7u 1icG Works
uk5lic tilities
Public Safety
Fire Services
Review fee $ Depf_Signature �
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed b ' Date:
21
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable
PUBLIC WORKS ' Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017 ?kav\5 —DO n �h. LWv L, ckp _�Y� ��I 111111 �, ` �K./
City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
`. 800 Seminole Road c n C
Atlantic Beach, Florida 32233-5445
- Phone(904)247-5826 • Fax(904)247-5845 l
E-mail: building-dept@coab.us Date routed:
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 0 LQCt_() Department review required Yes No
ildin
Applicant: `� S
LQ nein &Zon' `
pp )6J t l ` ..._ a
Tree Administrator
Project: GLS b P./,� u lic6 worms
ublic Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept.of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. Denied. ❑Not applicable
(Circle one.) Comments�Icl(ve_X ,
BUILDING
PLANNIN OZ&G NING_"7 i /
--= --_ Reviewed byG9 Date: 2 ( 3 "( 7
TREE ADMIN. Second Review: ❑Approved as revised. KDenied. []Not applicable
PUBLIC WORKS Comments:�
PUBLIC UTILITIES
PUBLIC.SAFETY Reviewed by. Date: (2�(y�l 7
FIRE SERVICES Third Review: ❑Approved as revised. [-]Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
(tip �`' ✓' �-�
L
_ CITY OF ATLANTIC BEACH
0 E C 1 22017 800 Seminole Road
Atlantic Beach,Florida 32233
REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS
Date 12- ) Z ) 1 Revision to Issued Permit Corrections to Comments/ Permit# V--I✓•SAO-O cqs-
Project Address y Z--
Contractor
Contractor/Contact Name E U a l,eIrr�y �. C
Phone / /i/ ! Email 241 L'b l ps
Description of Proposed Revision/Corrections: Permit Fee Due$
Additional Increase in Building Value$ - — Additional S.F.`-----
By signing below,I ���C�lfi/�- � a�G j �i affirm the Revision is inclusive of the proposed changes.
(pr' ted name)
/2- 12- ) 7
Sig ture of on ctor/Agent(Contrac must sign if increase in valuation) Date
(Office Use Only)
Approved Denied Not Applicable to Department
Revision/Plan Review Comments J re(f
DeparPn
ent Review Required:
Buildin �-
Plaan'mg Reviewed By
Tree Ad istrator
(Z-PU-5111c Wor{
Pub is i ities f T
Public Safety Date
Fire Services
�_ R
3' L t ��
sq CITY OF ATLANTIC BEACH
D E C 2 2017 1 1 800 Seminole Road
Atlantic Beach,Florida 32233
REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS
Date 12- 12, 11 Revision to Issued Permit Corrections to Comments/ Permit# �Srl��� teas-
Project Address R 9 2 "O"q, 'e,
Contractor/Contact Name Pq �1 if gn lot rrs L L_ C
Phone ,?6
Y 9 � � Email P#1 u"I PSg�J>�� �COMM
Description of Proposed Revision/Corrections: Permit Fee Due $
Additional Increase in Building Value $ Additional S.F.---'
By signing below,If(/l Q11Lf PAJ ) affirm the Revision is inclusive of the proposed changes.
(pri ted name)
/2- 12-
Si
ZSig tune of on ctor/Agent(Contrac must sign if increase in valuation) Date
(Office Use Only)
Approved_ Denied -Not Applicable to Department
Revision/Plan Review Comments
Depa ent Review Required:
Buik I
Planning &Zoning Reviewed By
Tree Ad ` istrator
u is Worl
Pubic i ities
Public Safety Date
Fire Services
NO'T'ICE OF COMMENCEMENT
T
.... ..... . ....
Du'
State*.ofCounty of -: Tax Folio No.
To Whom It May Concern:
The undersigned hereby informs:you that improvements will be made to certain real property, and in accordance with Section 713 of::.
-the Florida Statutes;the:follow' g information is stated in this NOTICE OF COMMENCEMENT. ---
Legal Description of property being improved:.
Address of property beingimproved: �� 0cEA0
General description of improvements;
A � g _
Owner: l Ll%h � L�� Address: q q Z O C 7Atj 0 4 ujO . • (3J''1
Owner's interest in site of the:improvement:
Fee.Simple Titleholder(if other than owner):
Name.:: t(.AIAl (, tAA
Contractor:... .C,
Address:
Telephone No.: _ Fax No:
Surety(if any)-. ..
Address:
Amount:o.f B and
Telephone No: Fax No:
. .. .
Name and address of:any personmaking a loan for the construction:of the improvements.:
Name:
Address:
_. p._
Phone No; Fax No:
Name of person within the State of Florida, other than himself, designated by owner upon whom notices.or other documents may be
served: Name:
Address:
Telephone No: Fax No: : .. .
in addition to,himself, owner designates the following person to receive a copy. of the Lienor's Notice as provided in Section
713..06(2)(b),Florida Statues. (Fill in at Owner's:option)
Name: .... . .... . ._. . ....
Address: .
-Telephone No: Fax No:
Expiration date of-Notice of Commencement(the expiration date is one (1)year from:the date of:recording;unless a;different date,.is
specified): .. . .
THIS SPACE FOR RECORDER'S USE ONLY: .OWNER at
... .
Signed: D e::: 7 ".
gn
...: Before me is::)Cl, day of D ZO 1 in the County f Duval,State
— -- --- Of Florid ,has personally a e
P Y PP --
Doc#?2017290052,OR BK 18225 Page 1022, - Personally Known: or
umber Pages::1
g Produced:Identification.
Recorded 12119/2017 10::47 AM,
Notary Public:
RONNIE FUSSELL CLE
'R
DUVAL:
COUNTY .. My commission expires:
:RECORDING $10.00
_.
i tr5n_,•.a,,v�u;:ue:>sws:,.sa,�<:a�,-rn,�i�,. .. s„as:j 'q.
U r!<,- - Tt)Nf.GIfUJI_ESPERGtR..
r�ll'rso
t�riVISSION�2,4�9�5 -
- -
XPIR�S 0 lo
i E;nded Thru Notary Pu
I �
U
' o•
00
2
a �
-4R 169e M St�o'er,Egg �3
VJ
0
I0�. G30n53.
7.;N/ 1ON I O 5/ LafW j s/Hl O O 3
1
"C J \p
Q41o� C-0 �
J �. ,ez 04it
�' 0 a3so7�'9 �� , Q
\W
W w ry0• Q U� � n `j�• z ,`� � � O
Ck
: ;4.
� .Is• o$ 4
Ul
O • 39N3a13�98/ 9N/a/b�B E'65
WNL q.
41
o z4,g
,00bJ Z
4O
.:..:. .. . .
rMAP SHOWING BOUNDARY SURVEY OP
A PART OF SECTION 16, TOWNSHIP 2 SOUTH, RANGE 29 EAST, DUVAL
COUNTY, FLORIDA, MORE PARTICULARLY DESCRIBED AS FOLLOWS:
FOR A POINT OF BEGINNING COMMENCE AT THE NORTHEAST''CORNER
OF LOT 18, BLOCK 1, ATLANTIC BEACH PARKWAY, AS RECORDED IN
PLAT BOOK 15, PAGE 61 OF THE CURRENT PUBLIC RECORDS OF SAID
COUNTY; THENCE S.06°23'15"E. ALONG THE EAST LINE OF SAID LOT 18,
A DISTANCE 0F(8:%.&O-FEET; THENCE RUN N.83940'45"E.,
A DISTANCE OF
95.19 FEET TO
WESTERLY RIGHT-OF-WAY LINE OF OCEAN
BOULEVARD(FORMERLY CONTINENTAL AVENUE)AS ESTABLISHED BY
SAID ATLANTIC BEACH PARKWAY AS BEING A 20.00 FOOT RIGHT-OF-
WAY, SAID RIGHT-OF--WAY LINE BEING CURVED CONCAVE TO THE
WEST HAVING A RADIUS OF 193.00 FEET; THENCE R OF NORTHERLY
ALONG THE ARC NOF SAID CURVE A CHORD BEARING
E.
AND A CHORD DISTANCE OF 87.26 FEET TO THE SOUTH RIGHT-OF-WAY
LINE OF 10TH STREET, AS NOW ESTABLISHED AS A 40.00 FOOT RIGHT-
OF-WAY; THENCE RUN S.83 40 45'W. ALONG SAID RIGHT-OF-WAY LINE
OF 10TH STREET, A DISTANCE OF;1-5.0j�)FEET TO THE POINT OF
BEGINNING.
City of Atlantic Beach APPLICATION-NUMBER
F Building Department (To be'assigned by tFie Building Department:)
rY 800 Seminole Road
Atlantic Beach, Florida 32233-5445
Phone(904)247-5826 • Fax(904)247-5845
rt E-mail: buildin de t coab.us Date 7routed
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 1 000a l) ��y� Department review required Yee No
1ildin ;/
Applicant: `� 5 �J�c ��� �'�'�- nning &Zon'
Tree Administrator
Project: ly)GLS-t4 (�(D(�� Qt 3,/1 u F works
ub is tilities
Public Safety
Fire Services
ReVieW;fee $._ DeptSignature -
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: E proved. ❑Denied. [-]Not applicable
(Circle one.) Comments:
�: 13ULLDING '''
PLANNING &ZONING Reviewed by: Date: /Z'1 ZrG7
TREE ADMIN. Second Review: []Approved as revised. []Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
CITY OF ATLANTIC BEACH
' 800 Seminole Road
j DEC 1 G.� + 3 �R1� �� ;�; Atlantic Beach,Florida 32233
,
I
REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS
Datel2 )3 11 Revision to Issued Permit_ Corrections to Comments_ Permit# 9,eSA r1--C)c)�}
Project Address `Z (--'1 2, 0 C ieA� AJ
Contractor/Contact Name
Phone 904 ' Email Y �k%L(4 V S C,0K1 eA - Ale-r
Description of Proposed Revision/Corrections: Permit Fee Due$
� p Tv
F� CSG d U n0 CLM6J -J
Additional Increase in Building Value $ Additional S.F.
By signing below,I Au4i affirm the Revision is inclusive of the proposed changes.
i
rinted name)
Yiature of Contractor/Agent(Conti ctor must sign if increase in valuation) Date
(Office Use Only)
Approved T Denied Not Applicable to Department
Revision/Plan Review Comments
Department Review Required:
Bui
E'`dlPlannin &Zonin"�
T ee Administrator
Public Works
Public Utilities I 157—f
7
Public Safety Date
Fire Services
- TREE & VEGETATION AFFIDAVITi
Choi y®f Atiant k Beach
N; y' Department of Community Development
Planning&Zoning Division
;r 800 Seminole Road Atlantic Beach, FL 32233
(P)904 247-5800 (F) 904 247-5845 PERMIT#
SECTION I-APPLICANT INFORMATION � Owner(s) Legal Authorized Agent*
i
NAME OF APPLICANT
NAME OF COMPANY SV;V) 'n
f ADDRESS OF COMPANY (� lz_
!
PHONE EMAIL
i
CONTRACTOR CERTIFICATION NUMBER ZS--� )4
ATLBCH BUSINESS TAX RECEIPT NUMBER �
SECTI®N II-SITE INFORMATION 1
STREET ADDRESS OF PROPERTYOU
I
]fan address has not been assigned to this property,contact the AB Building Department at(904)247-5826 to request an address.
LEGAL DESCRIPTION
LOT , BLOCK SUBDIVISION f
REAL ESTATE NUMBER LOT OR PARCEL SIZE: '
SQ FT AC
i RESIDENTIAL COMMERCIAL OTHER(SPECIFY) j
1 affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation"of the Municipal Code of
Ordinances for the City of Atlantic Beach,FL and/or/have participated in a pre-application meeting with the Administrator of those
regulations. Subsequently,I affirm that no regulated trees and no regulated vegetation will be damaged, destroyed and/or removed I
from the above- escribed or djacent properties in conjunction with this project.
SIG ATURE OF OWNER SI NATURE OF OWNER
I
I Signed and sworn before me o this ' y of ` ,by State of
County of 0U
Identification verified
1 Oath sworn: `
i j— Yes �" N
t Notary Signature �! �i'co,r,:.,ISIOIw,rrr y J
F. �... •-- •'4.
EXPIRES:October 6,2019 yH
My Commission expires:
r'; .i xr 'i Vu,:; 'ry �b,�c Unce�riri?� 8
CITY OF ATLANTIC BEACH
DEC 1 2 2017 800 Seminole Road
f i� LE•I _ Atlantic Beach,Florida 32233
REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COMME®TS 9 2017
u c. LJ
Date dZ 1 Z 1 7 Revision to Issued Permit Corrections to Comments/ Permits S o
Project Address �� l �`l=Q a✓ 5�: ti 5 2
Contractor/Contact Name �� b � ' Rai )"d9 pr'�y L L L
Phonego �9 Email 1 .,41 L.&l Ps L� �C M6
Description of Proposed Revision/Corrections: Permit Fee Due$
Additional Increase in Building Value$ - — Additional S.F.--'
By signing below,I PAJLL j affirm the Revision is inclusive of the proposed changes.
(pri ted name)
` r /Z 12-
Sig tune of on ctor/Agent(Contrac must sign if increase in valuation) Date
(Office Use Only)
Approved Denied Not Applicable to Department
Revision/Plan Review Comments
D!! a ent Review Required:
Buildin
Planning &Zonin Reviewed By
Tree�Xp ist.ator
u lic Worms
- P-� VVO
C�Pub rc i itiesi'
Public Safety Dat
Fire Services
X loons - Do (avy_
U,z 29
CITY OF ATLANTIC BEACH
DEC
2 2017 1 800 Seminole Road
Atlantic-Beach;Florida 3223,3
L
DEC 13 2017.
REVISION REQUEST CORRECTIONS TO PLAN REVIEW COMMENTS
Date Revision to Issued Permit Corrections to Comments/ Permit cqs-
9, -5
Project Address Z-1
Contractor/Contact Name Pq w IYJ Rn!'Urry LL- e I
Phone 9 Email d1.lJ I PS e0)'L-Ve1ZC0 COME
Description of Proposed Revision/Corrections: Permit Fee Due$
Additional Increase in Building Value $ Additional S.F.---'
By signing below,I ef//opel, PAJ )iL IU affirm the Revision is inclusive of the proposed changes.
(Pa ted name)
Si hire of on (Contrac must sign if increase in valuation) Date
(Office Use Only)
Approved Denied Not Applicable to Department
Revision/Plan Review Comments �7-(Ci relr-�
DepAT=,ent Review Required:
3(-Kildin /
Planning &Zonin Reviewed By.
MiEiD
Tree 6d�' isitrator
Y Lf 7
'r
ic W�'i
U
1c
-P Safety ies
U' fe DAte
15 is�a
Fire Services
Plaves�D Jar t-� Las-W-C c k e,
1-�f. +t.:�+�.�j,� • • • • • :f—'1 �� ��l e 7 r? '7'i t'� tT1, 7
Building Permit Application f l �1pdz, ef6T
FFICE COPY City of Atlantic Beach '
Dl�
800 Seminole Road, Atlantic Beach, FL 32233 �?4
Pa,i1} DEC - 5 2017
Phone: (904) 247-5826 Fax: (904) 247-5845
Job Address: C? ) Z OCC-A0 131OC2 R,, F L. '37-Z3-? Permit Number:
Legal Description GT g 16CA] - �S� yjrr RE#
Valuation of Work(Replacement Cost)$ Heated/Cooled SF 9 W Non-Heated/Cooled
• Class of Work(Circle one): New ddition Alteration Repair Move Demo Poo Window/Door
• Use of existing/proposed structure(s) Circle one): Commercial esidential
• If an existing structure, is a fire sprinkler system installed?(Circle one): Yes No N/A
• Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit OTNoDree Removal
Describe in detail the type of work to be performed:
A.rv-' IZ i4 IT ddJV
Florida Product Approval# for multiple products use product approval form
Property Owner Information
Name: ^_L. 4t q,�l_ i�l�'��a OS Address: CA 2o OCIRke4 ,IV10
City State Gl Zip "'-L2,2 J_—Phone !1,14,
E-Mail 4
Owner or Agent(If Agent, Power of orney or Agency Letter Required)
Contractor Information I
Name of Company.X I,.� PS 1-L.f ePs- L-U(.. Qualifying Agent:
Address '992- OC,64,/ rR-LP0 .-4,S, 12,3Z'LZ3 City A A . State tel. Zip 3z2�33
Office Phone Job Site/Contact Number
State Certification/Registration# e-(9c-fzn 3I+ E-Mail r3ASUNPs &'AdCM 65.% C&I'm- NPT
Architect Name& Phone#
Engineer's Name&Phone#
Workers Compensation
xempt surer/Lease Employees/Expiration Date
Application is hereby made to obtain a permit to dot a work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
.
r �
(Signature of Owner or ent) (Signature of Contracto )
(including contractor)
Signed and sworn to(or affirmed before me this qday of Signed and sworn to(or affirmed) before me this day of
DCB. MbW, l:, by GlyLeil P dlUos- mQgeew6x. by BWAR.iAl Poo Et(D�S
• AWAAI Z�
Amv&0.H01W. (Signature ofo ary) 0 (Signature of ary)
Commission 0 GG1370 ya" Artgnlle 8 Nodpes.
Egfres: DeC. 3, 2021 r Commission t GG137883
gas Bonded Mro Aaron Notary Expires: Dec. 3, 2021
Bonded w!i a,•„v...
personally Known OR s[,o]'Isersona)ly Known OR
[ ] Produced Identification [ ]Produced Identification
Type of Identification: Type of Identification:
OFFICE COPY.
��plzca e Co es: ZOIO FLORIDA BUILDING CODE ILow
- OFFICE USE ONLY
approved Disapproved
ApI ro ved w/Conditions
Review Initials/Date:
Develop—ment Size
Jabitable Space S'zv Noll-Habitable '
npervious area,
9.8cella,Meons Infox°ma on
xupaucy a- roup �3
Pe of Const-co-drion. .V
mber of Stories - '
K. Occupancy Load
SpTUders Required
d Zone
9WO- .s/comments:
t
- 1
OFFICE COPY
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA
Project Name: PK-,[ "�.� �U, 1Gtas LL C Permit # �.5�17-00-?$-
Project Address: j 9 Z 0 U674 n 3 Z
As required by Florida Statute 553.842 and Florida Administrative Code Rule 913-72,please provide the information and product approval number(s)
for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact
your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide
product approval may be obtained at:www.floridabuildin17.or .
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
A.EXTERIOR DOORS
1.Swinging
2. Sliding
3. Sectional (JG-.b WIJJ Fl— 4
4.Roll up
5.Automatic
6.Other IU�t t f W t ni Dow PCOL oA,
B.WINDOWS ��� "t 0 .
1. Single hung
2.Horizontal slider
3.Casement
4.Double hung
5.Fixed
6.Awning
7. Pass-through
8. Projected-
9.
rojected9.Mullion
10.Wind breaker
1 I.Dual action
12.Other
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
C. PANEL WALL
1.Siding
2. Soffits
3.EIFS
4. Storefronts
5.Curtain walls
6. Wall louvers
7. Glass block
8.Membrane
9. Greenhouse
1.0. Synthetic stucco
11.Other
D.ROOFING PRODUCTS
1. Asphalt shingles xA- Miwd 2. '( 1012-4, 1 v
2.Underlayments
3.Roofing fasteners
4.Nonstructural metal roof
5.Built-up roofing
6.Modified bitumen
7.Single ply roofing
8.Roofing tiles
9. Roofing insulation
10.Waterproofing
11. Wood shingles/shakes
12. Roofing slate
13.Liquid applied roofing
14.Cement-adhesive coats
15. Roof tile adhesive
16. Spray applied polyurethane
l roof
17.Other
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
E.SHUTTERS
1.Accordion
2.Bahama
3. Storm panels
4.Colonial
5.Roll-up
6.Equipment
i
7.Other
F.STRUCTURAL
COMPONENTS
1. Wood connector/anchor
2.Truss plates
3.Engineered lumber
4.Railing
5.Coolers-freezers
i
6.Concrete admixtures
i
I 7.Material
8.Insulation forms
9.Plastics
10.Deck-roof
11.Wall
12.Sheds
13.Other
G.SKYLIGHTS
1. Skylight
I
i
i
i
_ _. _-------.
� IT
a !
2.Other
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
H.NEW EXTERIOR
ENVELOPE PRODUCTS
l..
2.
In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the
Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation
instructions along with this Product Approval Sheet.
I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones
listed in this document must be approved by the Building Official.
(Contractor Name) rr(`P�rin�t"Name) "" I (Signature)
Company Name: PT cvi,s &J, L C-
Mailing Address: `1 Q 2- 61. iE-ptA/ PILW d
City: - Stater Zip Code: 3Z Z 33
Telephone Number:(4 6'4 St Q `" 29�� Fax Number:( }
Cell Phone Number: ( ) E-mail Address: yt
OFFICE COPY
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Phillips Addition Builder Name:
Street: 992 Ocean Blvd Permit Office:
City,State,Zip: Atlantic Beach,FL,32233 Permit Number:
Owner: Michael Phillips Jurisdiction:
Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2)
1. New construction or existing Addition 9. Wall Types(594.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 594.00 ft2
b.N/A R= ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms(Bedrms In Addition) 1(1) d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (520.0 sqft.) Insulation Area
a.Roof Deck(Unvented) R=20.0 520.00 ft2
6. Conditioned floor area above grade(ft2) 520 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(70.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 34
a. U-Factor: Dbl,U=0.45 40.00 ft2
SHGC: SHGC=0.40
b. U-Factor: Dbl,U=0.40 30.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 60.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 38.0 HSPF:8.30
SHGC:
Area Weighted Average Overhang Depth: 0.500 ft.
Area Weighted Average SHGC: 0.374 14.Hot water systems-None required
8. Floor Types (520.0 sqft.) Insulation Area a. Cap:N/A
EF:0.000
a.Floor over Garage R=19.0 520.00 ft2 b. Conservation features
b.N/A R= ft2
c. N/A R= ft2 15.Credits None
Glass/Floor Area: 0.135 Total Proposed Modified Loads: 17.83 PASS
Total Baseline Loads: 18.72
hereby certify that the plans and specifications covered by Review of the plans and Q�TU SrlT�i*
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance rgr ' r,,��. C
with the Florida Energy Code.
PREPARED BY: Thqp�rGGhweill/ Before construction is completed
DATE: 12/5/17 this building will be inspected for " ' j,
compliance with Section 553.908 *.
I hereby certify that this building, as designed, is in compliance Florida Statutes. , ,
with the FI 'da Ener f Code
OWN BUILDING OFFICIAL: X
DATE: DATE: / % Z-l7
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.055 Qn for whole house.
12/5/2017 8:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
PROJECT
Title: Phillips Addition Bedrooms: 1 Address Type: Street Address
Building Type: User Conditioned Area: 520 Lot#
Owner: Michael Phillips Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 992 Ocean Blvd
Permit Office: Cross Ventilation: County: Duval
Jurisdiction: Whole House Fan: City,State,Zip: Atlantic Beach,
Family Type: Single-family FL, 32233
New/Existing: Addition
Comment: FloddaEnergyCalcs.com
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL-JACKSONVILLE-INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Blockl 520 4680
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Master Bedroom 520 4680 No 2 1 1 Yes Yes Yes
FLOORS
# Floor Type Space R-Value Area Tile Wood Carpet
1 Floor over Garage Master Bedroom ---- ---- 520 ft2 19 0.3 0.7 0
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Composition shingles 536 ft2 64 ft2 Medium 0.72 No 0.9 No 20 14
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 520 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) Master Bedroom 1.08 Batt 520 ft2 0.11 Wood
12/5/2017 8:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
AdjacentCavity Width Height Sheathing Framing Solar BeloOmt Tn Wall Typew
SpaceEt n Ft
1 W Exterior Frame-Wood Master Bedro 13 20 9 180.0 ft' 0.87 0.23 0.7 0
2 N Exterior Frame-Wood Master Bedro 13 26 9 234.0 ft2 0.87 0.23 0.7 0
3 E Exterior Frame-Wood Master Bedro 13 20 9 180.0 ft' 0.87 0.23 0.7 0
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 E 3 Vinyl Low-E Double Yes 0.4 0.34 30.0ft' 0 ft 6 in 0 ft0 in Drapes/blinds None
2 N 2 Metal Low-E Double Yes 0.45 0.4 40.0 ft' 0 ft6 in 0 ft0 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 520 ft' 520 ft' 71 ft 9 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000286 390 21.41 40.27 .2202 5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.3 38 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 14 60 kBtu/hr 1800 drn 0.75 1 sys#1
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
ft'
DUCTS
/ ---Supply--- --Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 34 ft' Attic 12 ft' Proposed Qn Garage ---cfm 28.6 cfm 0.06 0.50 1 1
12/5/2017 8:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
TEMPERATURES
Programable Thermostat:None Ceiling Fans:
Cooling [ ]Jan r Feb [[ ]]Mar [ ]Apr Ma [X]Jun Jul [X]AugX]Se [ ]Oct [ ]Nov [ ]Dec
Heatin [X]Jan [X]Feb [X]Mar [ ]Apr I
May E ]Jun f Jul [ ]Au [ ]Sep []Oct [X]Nov [X]Dec
Ventin [ ]Jan [[[[ ]]]]Feb [[XX]]Mar [X]A r May ]Jun [ Jul [ ]Aug [ )Se [X]Oct [X]Nov [ ]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
12/5/2017 8:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
Building Input Summary Report
PROJECT
Title: Phillips Addition Bedrooms: 1 Address Type: Street Address
Building Type: User Bathrooms: 0 Lot#
Owner: Michael Phillips Conditioned Area: 520 sq.ft. Block/SubDivision:
#of Units: 1 Total Stories: 1 PlatBook:
Builder Name: Worst Case: No Street: 992 Ocean Blvd
Permit Office: Rotate Angle: 0 County: Duval
Jurisdiction: Cross Ventilation: City,State,Zip: Atlantic Beach,
Family Type: Single-family Whole House Fan: FL, 32233
New/Existing: Addition Terrain: Suburban
Year Construct: 2018 Shielding: Suburban
Comment: FloridaEnergyCalcs.com
CLIMATE
Design Design Temp Int Design Temp Heating Design Daily Temp
Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL JACKSONVILLE INTL ARPT 32 93 70 75 1281 49 Medium
UTILITY RATES
Fuel Unit Utility Name Monthly Fixed Cost $/Unit
Electricity kWh EnergyGauge Default 0 0.1188
Natural Gas Therm EnergyGauge Default 0 1.72
Fuel Oil Gallon EnergyGauge Default 0 1.1
Propane Gallon EnergyGauge Default 0 1.4
SURROUNDINGS
Shade Trees Adjacent Buildings
Omt Type Height Width Distance Exist Height Width Distance
N None Oft Oft Oft Oft Oft Oft
NE None Oft Oft Oft Oft Oft Oft
E None Oft Oft Oft Oft Oft Oft
SE None Oft Oft Oft Oft Oft Oft
S None Oft Oft Oft Oft Oft Oft
SW None Oft Oft Oft Oft Oft Oft
W None Oft Oft Oft Oft Oft Oft
NW None Oft Oft Oft Oft Oft Oft
BLOCKS
Number Name Area Volume
1 Blockl 520 4680
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
1 Master Bedroom 520 4680 No 2 1 Yes Yes Yes
FLOORS (Total Exposed Area= 520 sq.ft.)
# Floor Type Space R-Value Area Tile Wood Carpet
1 Floor over Garage Master Bedroom ___ ___ 520 ft' 19 0.3 0.7 0
12/5/2017 8:20 AM EnergyGauge®/USRCZB v5.1 Page 1 of 6
Building Input Summary Report
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Composition shingles 536 ft2 64 ft2 Medium 0.72 No 0.9 No 20 14
ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 520 ft2 N N
CEILING (Total Exposed Area= 520 sq.ft.)
# Ceiling Type Space R-Value Ins.Type Area Framing Fraction Truss Type
1 Under Attic() Master Bedroom 1.08 Batt 520 ft2 0.11 Wood
WALLS (Total Exposed Area= 594 sq.ft.)
Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in"Project"section above.
Ad' cent Cavity Width Height Sheathing Framing Solar Below
# Omt to Wall Type Space R-Value Ft In Ft to Area R-Value Fraction Absor. Grade%
1 W Exterior Frame-Wood Master Bedroo 13 20 9 180.0 ft2 0.67 0.23 0.7 0
2 N Exterior Frame-Wood Master Bedroo 13 26 9 234.0 ft2 0.87 0.23 0.7 0
3 E Exterior Frame-Wood Master Bedroo 13 20 9 180.0 f:2 0.87 0.23 0.7 0
Total Exposed Gross Wall Area: 594 sq.ft. Total Window Area: 70 sq.ft. Total Door Area: 0 sq.ft. Net Wall Area: 524 sq.ft.
WINDOWS (Total Exposed Area= 70 scift)
Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Storm Area Depth Separation Interior Shade Screening
1 E 3 Vinyl . Low-E Double Yes 0.4 0.34 N 30.0 ft2 0 ft 6 in 0 ft0 in Drapes/blinds None
2 N 2 Metal Low-E Double Yes 0.45 0.4 N 40.0 ft2 0 ft6 in 0 ft0 in Drapes/blinds None
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 Space(s)
1 Wholehouse Proposed ACH 50 .000286 390 21.41 40.27 .2202 5 All
GARAGE
# Floor Area Roof Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 520 ft2 0 ft2 71 ft 9 ft 1
MASS
Mass Type Area Thickness Furniture Fraction Space
No Added Mass 0 ft2 0 ft 0.3 Master Bedroom
12/5/2017 8:20 AM EnergyGauge®/USRCZB v5.1 Page 2 of 6
Building Input Summary Report
HEATING SYSTEM
# System Type Subtype Efficiency Capacity ---Geothermal HeatPump-- Ducts Block
Entry Power Volt. Curr
1 Electric Heat Pump Split HSPF:8.3 38 kBtu/hr 0 0 0 s s#1 1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Ducts Block
1 Central Unit Split SEER:14 60 kBtu/hr 1800 cfm 0.75 s s#1 1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length
gal gal deg
Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
System Type length length power Connected Flow Eff
DUCTS
DUCT -----Supply Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 34 ft2 Attic 6 12 ft2 Proposed Qn Garage ---cfm --cfm 0.06 0.50 1 1
TEMPERATURES
Programable Thermostat:None Ceiling Fans: N
CoolingJan Feb Mar Apr Ma X�Jun Jul [X]Au Se ( ]Oct [ ]Nov Dec
HeatinJan Feb Pq Mar Apr f May ]Jun l Jul E ]Au4 Sep [ ]Oct [X]Nov Dec
Vent in Jan Feb Mar Apr [ May ]Jun [ Jul ]Aug [ Se [X]Oct [X]Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
12/5/2017 8:20 AM EnergyGauge®/USRCZB v5.1 Page 3 of 6
ID Type Screen Location Capacity Fuel Type Make Model Schedule LoadsPerYr
1 Dryers Default New Main Natural G
12/5/2017 8:20 AM EnergyGauge@/USRCZB v5.1 Page 4 of 6
Building Input Summary Report
APPLIANCES&LIGHTING
Appliance Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Ceiling Fans(Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33
%Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Clothes Washer AM 0.105 0.081 0.046 0.046 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872
%Released: 60 PM 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443
%Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1
%Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11
%Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28
Annual Use: 871 kWh/Yr Peak Value: 284 Watts
Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53
%Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1
%Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Range AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4
%Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8
%Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 0.95 0.93 0.9 0.85
Annual Use: 775 kWh/Yr Peak Value: 140 Watts
Well Pump AM 0.05 0.05 0.05 0.05 0.05 0.05 0.1 0.1 0.1 0.1 0.1 0.1
%Released: 0 PM 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
REFRIGERATORS
ID Type Screen Location Quantity Vol FrZ.Vol Make Model Schedule kWhPerYr
1 Default New Main 1 691
CLOTHES WASHERS
ID Type Screen Location Capacity Make Model Schedule LoadsPerYr
1 Cl.washe Default Existing Roomsln 2.874000 HERS2011 328
Building Input Summary Report
DISHWASHERS
ID Type Screen Location Capacity Vintage Make Model Schedule kWhPerYr
1 Dishwash Energy Guide Roomsln 12 EStarRef EStarRef HERS2011 142
RANGE OVEN
ID Type Screen Location Type Fueltype Make Model Cooktop Oven
1 Ranges Default New Roomsln CooktopOven C Electric Electric FI Not Conv
HARD WIRED LIGHTING
ID Type Screen Location Total# Qualify# Comp FI All Other FL txtBulbtype Schedule Watts per bulb
1 Hard-Wir Default 1st Floor 20 2 0 2 Incandes HERS201 60
2 Hard-Wir Default 2nd Floor 20 2 0 2 Incandes HERS201 60
3 Hard-Wir Default Bonus Ro 20 2 0 2 Incandes HERS201 60
4 Hard-Wir Default Exterior 20 2 0 2 Incandes HERS201 60
5 Hard-Wir Default Garage 20 2 0 2 Incandes HERS201 60
MISC ELECTRICAL LOADS
ID Type Screen Item Quantity Category Operating Location Schedule Off Standby
1 Misc Elec Simple Default 1 1 Main HERS2011 1
12/5/2017 6:20 AM EnergyGauge®/USRCZB v5.1 Page 5 of 6
Building Input Summary Report
APPLIANCES&LIGHTING SCHEDULES
Appliance Schedule: HERS2014 Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Occupancy peak: 400 Btu AM 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.98 0.46 0.27 0.27 0.27
%Released: 100% PM 0.27 0.27 0.27 0.27 0.33 0.61 1 1 0.93 0.93 0.93 0.93
refrig peak: 0 W AM 0.824 0.804 0.784 0.764 0.744 0.734 0.744 0.754 0.764 0.794 0.814 0.854
%Released: 100% PM 0.854 0.864 0.884 0.904 0.925 0.945 0.925 0.915 0.904 0.894 0.874 0.854
cWash peak: 0 W AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1
%Released: 30% PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375
E-cDry peak: 0 W AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1
%Released: 15% PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375
dWash peak: 0 W AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443
%Released: 60% PM 0.376 0.396 0.334 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281
E-rOven peak: 0 W AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4
%Released: 80% PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114
TVs peak: 176 W AM 0.1 0.05 0.05 0.05 0.1 0.2 0.4 0.45 0.4 0.2 0.1 0.1
%Released: 100% PM 0.05 0.05 0.15 0.45 0.85 1 0.95 0.8 0.5 0.25 0.15 0.1
cFan peak: 0 W AM 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.25 0.25 0.25 0.25 0.25
%Released: 100% PM 0.25 0.25 0.25 0.25 0.25 0.25 0.55 0.6 0.6 0.6 0.6 0.6
Igts-in peak: 0 W AM 0.16 0.15 0.16 0.18 0.23 0.45 0.42 0.26 0.19 0.16 0.12 0.11
%Released: 100% PM 0.16 0.17 0.25 0.27 0.34 0.55 0.6 0.88 1 0.88 0.51 0.28
Igts-out peak: 0 W AM 1 1 1 1 1 0.75 0.75 0 0 0 0 0
%Released: 0% PM 0 0 0 0 0 0 0 0.5 0.75 0.75 0.75 1
Igts-gar peak: 0 W AM 0 0 0 0 0 0.5 0.75 1 0.75 0.5 0 0
%Released: 0% PM 0 0 0.5 0.5 0.75 1 0.75 0.5 0 0 0 0
MEL peak: 0 W AM 0.5 0.5 0.5 0.75 0.75 0.85 1 1 1 1 0.9 0.9
%Released: 90% PM 0.9 0.9 1 1 1 1 1 1 1 0.85 0.75 0.75
12/5/2017 8:20 AM EnergyGauge®/USRCZB v5.1 Page 6 of 6
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the EnergyPerformance Index, the more efficient the home.
992 Ocean Blvd, Atlantic Beach, FL, 32233
1. New construction or existing Addition 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 594.00 ft'
b.N/A R= ft
3. Number of units,if multiple family 1 c.N/A R= ft'
4. Number of Bedrooms 1(1) d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Roof Deck(Unvented) R=20.0 520.00 ft
6. Conditioned floor area(ft2) 520 b.N/A R= ft2
7. Windows" Description Area c.N/A R= ft 2
a. U-Factor: Dbl,U=0.45 40.00 ft' 11.Ducts R ft
a.Sup:Attic,Ret:Attic,AH:Garage 6 34
SHGC: SHGC=0.40
b. U-Factor: Dbl,U=0.40 30.00 ft'
SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 60.0 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 38.0 HSPF:8.30
Area Weighted Average Overhang Depth: 0.500 ft.
Area Weighted Average SHGC: 0.374
8. Floor Types Insulation Area 14.Hot water systems-None required
Cap:N/A
a.Floor over Garage R=19.0 520.00 ft' a. EF:
b.N/A R= ft2
c.N/A R= ft' b. Conservation features
15.Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building HESTAT
Construction through the above energy saving features which will be installed (or exceeded) ya = Ao
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: R
Address of Newdome: Od.04/ City/FL Zip:
0o y .
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/5/2017 8:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: 992 Ocean Blvd Permit Number:
Atlantic Beach,FL,32233
MANDATORY REQUIREMENTS See individual code sections for full details.
❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section
553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(0,(g),or(i)or an approved third party. A
written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
0 R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7),
Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g),or(1),Florida Statutes,to be"substantially leak free"by either of
the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
12/5/2017 5:13 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Softw Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can tum off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/1 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
0 R403.4.4.1 Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
• R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)
of combustion types of service water heating systems to be turned off.
0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
12/5/2017 5:13 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Soft Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
• R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
12/5/2017 5:13 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Soft Page 3 of 3
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: 992 Ocean Blvd Permit Number:
Atlantic Beach,FL,32233
MANDATORY REQUIREMENTS See individual code sections for full details.
13 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
■ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section
553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A
written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
E3 R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7),
Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"by either of
the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(2513a)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
12/5/2017 8:18 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Softw Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105•F(41°C)
or below 55°F(1 WC)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
O R403.4.4.1 Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
• R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
O
R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
12/5/2017 8:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Soft Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
0 R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
• R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
® 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
12/5/2017 8:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Soft Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Phillips Addition Builder Name:
Street: 992 Ocean Blvd Permit Office:
City,State,Zip: Atlantic Beach,FL,32233 Permit Number:
Owner: Michael Phillips Jurisdiction:
Design Location: FL,Jacksonville
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
12/5/2017 8:19 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Phillips Addition Builder Name:
Street: 992 Ocean Blvd Permit Office:
City,State,Zip: Atlantic Beach,FL,32233 Permit Number:
Design Location: FL,Jacksonville Jurisdiction:
Cond.Floor Area:: 520 sq.ft. Cond.Volume: 4680 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data: CFM(50):
C: n: R:
ELA:
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: EgLA:
1 Pa cfm ACH:
2 Pa cfm SLA:
3 Pa cfm ACH(50)
4 Pa cfm
* For prescriptive projects, tested leakage must be
5 Pa cfm <=7 ACH(50). For performance projects, tested
6 Pa cfm leakage must be<=the ACH(50)shown on Form
R405-2014 for this project.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour
in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by
either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(0,(g),or(i)or an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage Testing shall be conducted by either
individuals as defined in Section 0 �
performance results demonstrate compliance _IV I
553.993(5)or(7) Florida Statutes or
with Florida Energy Code requirements in individuals licensed as set forth in
accordance with Section R402.4.1.2. Section 489.105(3)(f), (g), or(i) or an
approved third party. A written report
`� of the results of the test shall be signed
SIGNAT b the third art conducting the test 1
Y party 9 �y
A4
and provided to the code official. �''ODWEI
PRINTED NAME:
BUILDING OFFICIAL:
DATE: '
DATE:
12/5/2017 8:19 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Phillips Addition Builder Name:
Street: 992 Ocean Blvd Permit Office:
City,State,Zip: Atlantic Beach,FL,32233 Permit Number:
Design Location: FL,Jacksonville Jurisdiction:
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
1 System 1 cfm25(Out)
2 System 2 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 1-4
Duct System
Divide by
Leakage (Total Conditioned Floor Area)
_ (Qn,Out)
I certify the tested duct leakage to outside, Qn, is Duct ti htness shall be verified b '�ST,4
not greater than the proposed duct leakage Qn g y 04 = T
testing to Section 803 of the RESNET ; , _.<0.�
specified on Form R405-2014. '
Standards by either individuals as � '
defined in Section 553.993(5)or(7), U a'I' " " a !" e
Florida Statutes, or individuals licensed7 1�y 0
SIGNATURE- K / as set forth in Section 489.105(3)(f), 0 L�„1�fI g �
(g), or(i), Florida Statutes.
PRINTED NAME: ^64061 I )L fCIO wr"T��
DATE: !( j7 BUILDING OFFICIAL:
DATE:
12/5/2017 8:19 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Sof Page 1 of 1
FORM R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page) and an input summary checklist that can
be used for field verification(usually 4 pages/may be greater).
❑ Energy Performance Level(EPL) Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed
Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge®-USRCZB v5.1
12/5/2017 5:12:59 AM Page 1 of 1