1629 BEACH AVE - PERMIT 17-POOL-3477 City of Atlantic Beach -APPLICATION N.UMBER
Building Department (To be assigned by the Building Department.)
800 Seminole Road
Al'-7
Atlantic Beach, Florida 32233-5445
- Fax(9
Phone(904)247-5826 04)247-5845
E-mail: building-dept@coab.us Qate.,routed:
City web-site: http://vmw.coab.us I
APPLICATION REVIEW AND TRACKING FORM
DeggLment review required Yes No
Property Address: WD-a� 1�tkuv\ )W\
RTLU I�11NM T
Applicant: Planning &
Tree Administrator
Project: P c WorEC�
(�_:!Eub�lic UtilitiQ_,Z1
Public Safety
Fire Services
LReyie�w fee $ De t Si_qnature
Review or Receipt
Other Agency Review or Permit Required of Permit Verified By Date
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS J
Reviewing Department First Review: ElApproved. FIDenied.
(Circle one.) Comments:
P I LANNING &ZONING Reviewed by: Date:
TREE ADMIN.
Second Review: ElApproved as revised. FIDenied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: F]Approved as revised. ElDenied.
Comments:
Reviewed by: Date:
Revised 05/14109
ill JAN-
ZONING REVIEW COMMENTS
City of Atlantic Beach
Community Development Department
800 Seminole Road Atlantic Beach, Florida 32233-5445
Phone: (904)247-5826 Fax: (904) 247-5845 Email: dreeves*coab.us
Date: 03/26/17
Permit: 17-POOL-3477 Applicant: Crown Pools, Inc.
Review: ist Address: 3002 Philips Hwy, Jacksonville, FL 32207,
Site Address: 1629 Beach Avenue Phone: (904) 826-7034 1
RE#: 169650-0000 Email: Not provided Q�ugp5000@gmail.com—owner)
Correction Comments
1. Setbacks: Section 24-67(c) requires a site plan showing setbacks. Please provide a site plan showing
setbacks from all new elements to property lines, including the proposed retaining wall.
2. Tree Removal: Section 23-21 requires a Tree Removal Permit for any trees removed within 2 years of
this project. Please submit a Tree Removal Permit Application if any trees are to be removed or were
removed in the last 2 years. If no trees are to be removed or were removed, then please fill out an
Affidavit of No Tree Removal. Both forms, are available on the city website under "Planning and
Zoning" and at City Hall.
Derek W. Reeves
Planner
dreeves@coab.us
City of Atlantic Beach APPLICATION NUMBER
I 6—Buil-ding-Department- --(T-o-be--assigned-by-the-6uildihg-Departrrient.)--
800 Seminole Road 14- L:�� Lt
t antic Beach, Florida 32233-5445
Phone(904)247-5826 - Fax(904)247-5845
E-mail: building-dept@coab.us Date routed:
Cityweb-site: hftp://vmw.coab.us
APPLICATION REVIEW AND TRACKING FORM
Prope rity Ad d ress: Depgrtment review required Yes No
sg��io a-,-2
Applicant: aw E)nni,in, i
_rree Administrator
Project: svokTA ic Wor s
Public Safety
Fire qprvices
Deo
Review or Receipt
Other Agency Review or Permit Required Date
of Permit Verified!By
Florida Dept. of Environmental Protection
FloridaTept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers�_�
Division of Hotels and Restaurants.
Division of Alcoholic Beverages and Tobacco
Other.
APPLICATION STATUS
'Reviewing Department First Review: []Approved. ',._RDenied.
(Circle one.) Comments:
BUILDING
AWT
Reviewed by:
Date:
TREE ADMIN.
Sbcond Review: ElApproved as revised. FIDenied.
P Di Inj
UBLIC WORKS Comments:
zP,UBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: DApproved as revised. OlDenied.
Comments:
Reviewed by: Date:
Revised 05/14/09
City of Atlantic Beach APPLICATION NUMBER
-the-BuiIdihg-Departrrf&r1t-.y-
Building-Department— (To-be-assigned-by
800 Seminole Road ecelve I Poo
Atlantic Beach, Florida 32233-5445 MAR I L:�� L
Phone(904)247-5826 - Fax(904)247- 5 5 2017
E-mail: building-dept@coab.us Date routed:
BY.
Cityweb-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: )P)auv� M_ PMartment review required Yes No
Applicant: Plan iing &Zonina�)
Tree Administrator
Project:
\J z®R b I aw—1 i I i—t,r_w
Public Safety
Fire Services
-''eview' fee $ Dep ,,qi ffato e.
Review or Receipt
Other Agency Review or Permit Required of Permit Verified By Date
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLn�ff ION STATUS
Reviewing Department First Review: VApproved. E]Denied.
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: Date:
TRE DMIN. Second Review: ElApproved a.s revised. OlDenied.
WORKS Comments:
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: DApproved as revised. ElDenied.
Comments:
Reviewed by: Date:
Revised 05/14109
CITY OF ATLANTIC;BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
(904) 247-5800
BUILDING DEPARTMENT REVIEW COMMENTS
Date: 3.23.2017
Permit 4: 17-POOL-3417 Site Address: 3002 Phillips Hwy.,JAX
Site Address: 1619 Beach Ave.,AB Phone: 858-4300; 826-7034
Review: I Email: keith*crownpoolsinc.com
RE#:
Homeowner: Kurt Pfotenhauer,
kurtp5000*gmail.com
Alplicant: Crown Pool Inc.
p
CORRECTION COMMENTS:
1. The 2 sets of structural design plans from Lou Pontigo.nee&'to be signed and sealed.
2. Provide information as to the lacement of the auger piles, and when they were installed.
p
Mike Jones
Building Inspector/Plan Reviewer-
Cit� Of Atlantic Beach
800 Seminole Road
Atlantic Beach,.FL 32233-5445
Ofc (904) 247-5844
Fax (904) 247-5845
-ev e cv
tr a I le al
ea cA Ar
Poo
March 28, 2017
Ms.Jennifer Johnston
Building Permit Technician
City of Atlantic Beach
800 Seminole Rd.
Atlantic Beach, FL 32233
Dear Ms.Johnston,
We presently have a permit application under review to obtain approval to construct a pool at 1629
-BeachAve. While nothing about the design of the pool has changed,we would like to work with a
different pool contractor than the one identified on our initial application to Implement the design.
Rather than Crown Pools,we intend to use Pools by Jon Clarkson to construct our pool. The general
contractor on the project,Satilla, Inc. remains the same,and in conjunction with our landscape architect
Kelly Elmore,who designed the pool, is in the process of responding to your departments' request for
additional information to complete the permit.
Per our earlier conversation, I understand that Clarkson will need to file a new permit application so that
we appropriately associate his name with the project. This should happen in the very near future.
Please let me know if you require any additional information, and again,thank you for your
res onsi ness an e.
Best R rd s,
M
fps
Kurt Pfoten r
1629 Beach ve. MGh Sale*.Ahmed Ould Snsy Is"
ba
Atlantic Beach, FL 32233
State of
--Lc—County of
ubscribed and SW'
orn before me on
*.a.
(Notary SIgna
BUILDING PERmiT APPLICATION
CITY OF ATLANTIC]BEACH OFFICE COPY
800 Seminole Road,Atlantic Beach,FL 32233
Office(904)247-5826 Fax(904)247-5845
Job Address: 1629 Beach Ave PermitNumber:
Legal Description: 15-10 09-2S-29E N Atlantic Beach Unit No I PT Lot 6 Parcel 169650-0000
Floor Area of Sq.Ft.
Valuation of Work$ -4 19&D Proposed Work heated/cooled non-heated/cooled
Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door
Use of c�xis;tin /
. g proposed structure( circle one): Commercial Residenti�l
If an existing structure,is a fire sp=er system installed?(Circle one): Yes No N/A
Florida Product Approval#
For multiple products use product approval form
Describe in detail the type of work to be performed: In-Ground Swimming Pool
Property Owner Inforutation:
Name: Kurt Pfotenhauer A dress:1629 Beach Ave
City Atlantic Beach State FL Zip 32233 Phone
E-Mail or Fax#(Optional)
Contractor Information:
Company Name: Crown Pools Inc Qualifying Agent:Brad Correia
Address:3002 Philips HWY _City Jacksonville - State Fl, Zip 32207
Office Phone 904-858-4300 Job Site/Contact Number 904-826-7034 Fax
State Certification/Registration# CPC1456979
Architect Name&Phone.#
Engineer's Name&Phone# e4jj A /c-* Crotu-,n ro-O-5 (-0 A
Fee Simple Title Holder Name and Address
Bonding Company Name and Address
Mortgage Lender Name and Address
h mad a a per dgh in, ns di.cgd n rk or installation has commencedpri
or to the
"a' 0 Lo in hisper
11 n thisjurisdiction. 7' mit becomes null
0 f
g 0-K,,hd n or
sus r or a Veriod ofs�fi months at any time after
Plunibit'g
,Sygns, u,
ME 6�11s,P6i7ls, urnacay, Rofteis,Heaters,
4 e el or' sta"a
j to 0" 1 1''
a d 11 o " d1om anda d
m h or , . . 1.
(6) n k de
'Pp" 0 e e'y 'ep
Is a it n a'a w r
w ki t co: c d ithin
cu , f
is n 0 ap i b or 1 0
and " 'no I"m w t, rat P mu
f d de d d k
"""id"
Tajj� '0�m ... �fl tha pa e e r n
ks OnW��Con 011 , .
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR EWPROVEMENTS
TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO14i NOTICE OF
COMMENCEMENT.
1here certify that I have read and examined this application and know theAQ to be true and correct. Allprovisionso,
,flaws and ordinances governing this
�Pwork will be coTplied with whether specified herein or n f nti P a permit toes not presume to give authority to violate or cancR the
Provisions of any otherfederal,sta ,or local law regulating co ruct! 0 the rmance ofconsiructlon.
hc cons1r"c"o
'to
Signature of Ownerx/-�-* Signafture of Contracto
PrintNarne PrintName
................. .............................
d
Sworn to and sub before me Sworn to and subscribed before me )-7
this Dayof 16fttl 20
.20 1-4 t U\"Djk'-Dayof,4-�V'V/-.��
EA
VA W� li
V U-
blivr=ki
COMMISSION#GG 042984A e., -*. .
ANN HOWAR6
�y
Lctber 27,2020 sed 01.26.10
EXPIRES:Oct- MY COMMISSION#FF90
Pu i t
'y .6 ._
Bonded Thru Notary Public tln�detwflter.s EXPIRES Augu§t 05.2019
-Aw
0;;,i9,,8'0 15 3 FWridallowySenice.6ow
OFFICE COPY
COVER SHEET
Project Name: Pfotenhauer
Project Address: 1629 Beach Ave
Occupancy Class:Group R-3
Applicable Codes: 2007 FL Building Code,2008 National Electric Code,2007 Florida Fire Prevention
Code,COIAB Code Of Ordinances
Index:
DEP Permit
TDH Form
ASPS Form
Site Plan
Demo Plan
Pooll-ayout
Pool Grading
Pool Sections
Lighting
Equipment Cut Sheets
Engineering
Permit Pack prepared by:
Joe A erson
Crown Pools
904-858-4300
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Division of Water Resource Management
2600 Blair Stone Road-Mail Station 3522
Tallahassee,Florida 32399-2400
PERMIT NUMBER: DU-492
PERMITTEE
Kurt and Nancy Pfotenhauer
c/o Kevin Partel
Coastal Consulting& Restoration, PA
4230 Myrtle St.
St. Augustine, Florida 32084
NOTICE TO PROCEED AND PERMIT FOR CONSTRUCTION OR OTHER ACTIVITIES
PURSUANT TO SECTION 161.053, FLORIDA STATUTES
FINDINGS OF FACT: An application for authorization to conduct the activities seaward of the coastal
construction control line which are indicated in the project description, was filed by the
applicant/permittee named herein on September 22,2016, and was determined to be complete pursuant to
rule on December 8, 2016. The proposed project is to be located landward of the 30-year erosion
projection and the line of construction established by major structures in the immediate vicinity.
CONCLUSIONS OF LAW: After considering the merits of the proposal and any written objections from
affected persons, the Department finds that upon compliance with the permit conditions, the activities
indicated in the project description are of such a nature that they will result in no significant adverse
impacts to the beach/dune areas or to adjacent properties;that the work is not expected to adversely impact
nesting sea turtles, their hatchlings, or their habitat; and that the work is expendable in nature and/or is
appropriately designed in accordance with Rule 6213-33.005,Florida Administrative Code. The direct and
cumulative impacts to the beach and dune system that will be caused by the seaward location of the proposed
construction represent the maximum such impacts that are acceptable to the Department. Therefore, future
construction on the site seaward of the coastal construction control line shall not extend farther seaward of the
proposed structures approved pursuant to this permit. Based on the foregoing considerations, the
Department approves the application; authorizes construction and/or activities at the location indicated
below in strict accordance with the project description, the approved plans and the General Permit
Conditions which are attached and are by this reference incorporated herein,and any additional conditions
shown below, pursuant to Section 161.053(4), Florida Statutes.
EXPIRATION DATE: December 23, 2019
LOCATION: Between approximately 202 feet and 252 feet south of the Department of Environmental
Protection's reference monument R-46 in Duval County. Project address: 1629 &1631 Beach Avenue,
Atlantic Beach.
PERMITTEE: Kurt and Nancy Pfotenhauer
PERMIT NUMBER: DU-492
PAGE 2
PROJECT DESCRIPTION:
Swimming Pool
I. Location relative to control line: A maximum of 139.6 feet seaward.
2. Exterior dimensions: 32 feet in the shore-normal direction, including attached landward spa, by
12 feet in the shore-parallel direction.
3. Type of foundation: Pilings.
4. Deck Elevation: +21.0 feet(NAVD).
5. Inside bottom elevation: +14.5 feet(NAVD)
Excavation/Fill
I. Total volume of excavation: Approximately 191 cubic yards. Volume of net excavation: None.
All excavated material will be retained onsite.
2. Location of excavation: From landward of the dwelling and below the pool.
3. Volume of fill to be placed: Approximately 235 cubic yards, including approximately 44 cubic
yards of imported fill. See Special Permit Condition 3.
4. Location of fill to be placed: A maximum 140 feet seaward of the control line.See Special Permit
Condition 2.
Other Structures/Activities
I. Paver walkway along the south side of the pool and no farther seaward than the pool.
2. Frangible,paver pool deck along the north and south sides of the pool to extend no farther seaward
than the pool.
3. Upland, frangible, CMU retaining wall underneath the edge of pool deck a maximum distance of
140 feet seaward of the control line.
4. Landward driveway reconstruction.
5. Landscape plantings. See Special Permit Conditions 4,and 5.
PERMITTEE: Kurt and Nancy Pfotenhauer
PERMIT NUMBER: DU-492
PAGE 3
6. Pool lighting. See Special Permit Condition 6.
SPECIAL PERMIT CONDITIONS:
1. Prior to commencement of construction activity authorized by this permit, a preconstruction
conference shall be held at the site among the contractor,the owner or authorized agent,and a staff
representative of the Department to establish an understanding among the parties as to the items
specified in the special and general conditions of the permit. The proposed locations of the
structures shall be staked out for the conference. Contact Trey Hatch at (904) 655-1765 to
schedule a preconstruction conference.
2. Prior to commencement of construction activity authorized by this permit, a temporary
construction fence shall be erected along the seaward work limits. The fence shall remain in place
until the construction authorized by this permit is complete. The optimum siting of the
construction fence shall be determined during the preconstruction conference by the staff
representative of the Department so as to provide maximum protection to the existing vegetation
located on the site.
3. All imported fill material shall be obtained from a source landward of the control line. All fill
material shall consist of sand which is similar to that already on the site in both grain size and
coloration. This fill material shall be free of construction debris, rocks, or other foreign matter.
A sample of the sand shall be provided to the staff representative of the Department during the
preconstruction conference.
4. Prior to completion of construction activities authorized by this permit,the permittee shall remove
all invasive nuisance plants, such as listed in the Florida Exotic Pest Plant Council's List of
Category I and 11 Invasive Species. The permittee shall plant a mix of a minimum of three native
salt-tolerant species to restore any disturbed natural area seaward of the authorized structures.
Dune restoration plantings shall consist of salt-tolerant species indigenous to the native plant
communities existing on or near the site or with other native species approved by the Department.
Sod composed of non-native grasses is not authorized seaward of a major structure or decks.
Plantings in other areas of the project site shall not include invasive nuisance plant species such as
listed in the Florida Exotic Pest Plant Council's List of Category I and 11 Invasive Species.
6. All lighting shall be installed and maintained as depicted in the approved lighting schematic.
Underwater pool lighting shall be amber or red LED or equivalent and provide no more than V2
foot candle per square foot of pool surface area. There may be a decrease in the wattage of each
approved lamp and a decrease in the total number of each approved fixture without submitting a
modified lighting plan for review and approval. However, if a fixture or lamp is changed to a
different type, manufacturer or catalog number for any reason, or if the location of any fixture is
changed it shall be submitted for review and approval by the Department prior to installation. No
additional permanent exterior lighting is authorized.
PERMITTEE: Kurt and Nancy Pfatenhauer
PERMIT NUMBER: DU-492
PAGE 4
CAVEAT:
Due to potential adverse impacts to the beach and dune system that may result from additional development
on the property,the seaward extent of the permitted structures shall not be increased, nor will any additional
major structures be permitted which would exceed the limits established by the permitted construction seaward
of the coastal construction control line.
Approved plans are incorporated into this permit by reference.
Done and ordered this 23rd day of December, 2016, in Tallahassee, Florida.
Attachment: General Permit Conditions
FILING AND ACKNOWLEDGEMENT State of Florida
FILED, on this date, pursuant to S120.52 Department of Environmental Protection
Florida Statutes, with the designated
Department Clerk, receipt of which is
hereby acknowledged.
12/23/2016 Tony D.McNeal, P.E., Administrator
Deputy Clerk Date Coastal Construction Control Line Program
Division of Water Resource Management
PERMITTEE: Kurt and Nancy Pfotenhauer
PERMIT NUMBER: DU-492
PAGE 5
NOTICE OF RIGHTS
This action is final and effective on the date filed with the Clerk of the Department unless a petition for
an administrative hearing is timely filed under sections 120.569 and 120.57, Florida Statutes, before the
deadline for filing a petition. On the filing of a timely and sufficient petition,this action will not be final
and effective until further order of the Department. Because the administrative hearing process is
designed to formulate final agency action,the hearing process may result in a modification of the agency
action or even denial of the application.
Petition for Administrative Hearing
A person whose substantial interests are affected by the Department's action may petition for an
administrative proceeding(hearing)under sections 120.569 and 120.57, Florida Statutes. Pursuant to rule
28-106.201, Florida Administrative Code, a petition for an administrative hearing must contain the
following information:
(a) The name and address of each agency affected and each agency's file or identification
number, if known;
(b) The name, address, any e-mail address, any facsimile number, and telephone number of
the petitioner, if the petitioner is not represented by an attorney or a qualified representative; the name,
address, and telephone number of the petitioner's representative, if any, which shall be the address for
service purposes during the course of the proceeding; and an explanation of how the petitioner's
substantial interests will be affected by the agency determination;
(c) A statement of when and how the petitioner received notice of the agency decision;
(d) A statement of all disputed issues of material fact. If there are none, the petition must so
indicate;
(e) A concise statement of the ultimate facts alleged, including the specific facts that the
petitioner contends warrant reversal or modification of the agency's proposed action;
(f) A statement of the specific rules or statutes the petitioner contends require reversal or
modification of the agency's proposed action, including an explanation of how the alleged facts relate to
the specific rules or statutes;and
(g) A statement of the relief sought by the petitioner, stating precisely the action petitioner
wishes the agency to take with respect to the agency's proposed action.
The petition must be filed (received by the Clerk) in the Office of General Counsel of the Department at
3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000. Also, a copy of the
petition shall be mailed to the applicant at the address indicated above at the time of filing.
Time Period for Filing a Petition
In accordance with rule 62-110.106(3), Florida Administrative Code, petitions for an administrative
hearing by the applicant must be filed within 21 days of receipt of this written notice. Petitions filed by
any persons other than the applicant, and other than those entitled to written notice under section
120.60(3), Florida Statutes, must be filed within 21 days of publication of the notice or within 21 days of
receipt of the written notice, whichever occurs first. Under section 120.60(3), Florida Statutes, however,
any person who has asked the Department for notice of agency action may file a petition within 21 days
PERMITTEE: Kurt and Nancy Pfotenhauer
PERMIT NUMBER: DU-492
PAGE 6
of receipt of such notice, regardless of the date of publication. The failure to file a petition within the
appropriate time period shall constitute a waiver of that person's right to request an administrative
determination (hearing) under sections 120.569 and 120.57, Florida Statutes, or to intervene in this
proceeding and participate as a party to it. Any subsequent intervention (in a proceeding initiated by
another party) will be only at the discretion of the presiding officer upon the filing of a motion in
compliance with rule 28-106.205, Florida Administrative Code.
Extension of Time
Under rule 62-110.106(4), Florida Administrative Code,a person whose substantial interests are affected
by the Department's action may also request an extension of time to file a petition for an administrative
hearing. The Department may,for good cause shown,grant the request for an extension of time. Requests
for extension of time must be filed with the Office of General Counsel of the Department at 3900
Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, before the applicable
deadline for filing a petition for an administrative hearing. A timely request for extension of time shall
toll the running of the time period for filing a petition until the request is acted upon.
Mediation
Mediation is not available in this proceeding.
Judicial Review
Once this decision becomes final,any party to this action has the right to seek judicial review pursuant to
section 120.68, Florida Statutes, by filing a Notice of Appeal pursuant to rules 9.110 and 9.190, Florida
Rules of Appellate Procedure, with the Clerk of the Department in the Office of General Counsel, 3900
Commonwealth Boulevard,M.S. 35,Tallahassee,Florida 32399-3000; and by filing a copy of the Notice
of Appeal accompanied by the applicable filing fees with the appropriate District Court of Appeal. The
Notice of Appeal must be filed within 30 days from the date this action is filed with the Clerk of the
Department.
NewWWer Publication
The Agency will not publish or require the person requesting a permit to publish in a newspaper a notice
of receipt of the permit application or notice of Agency action granting or denying the permit.
Persons receiving a permit are advised that interested parties who become aware of Agency action
approving or denying the permit, or who observe work on the project within certain time frames without
any prior notice, may have rights to petition for an administrative hearing under Chapter 120, F.S. For
this reason, it may be in the best interest of the person proposing the activity to publish, at its expense, a
one-time"Notice of Permit Issuance"in a newspaper of general circulation in the county where the activity
is located meeting the requirements of Chapter 50, F.S. Agency staff can provide persons with the
information for such a notice upon request. Persons who are substantially affected by the proposed action
may petition for an administrative hearing within the time frames specified in the notice and Chapter 120,
F.S.
Swimming Pooi,',-::nergy Efficiency Compliance Information Determine Pipe Sims:
NOTE:These Requirements Apply ONLY to the Filtration Pump Nanch Pipirig to be inch to keep veto*@ G fps max.at gpm System Flow Rate.
frunk,Skimmer&
ANSl/APSP/lCC-.j5 2011 Suction Piping to be �nch to keep velocity @ fps m9:.at gpm System Flow Rato�
Flow Calculations Return Piping to be rich to keep velocity @ Hil fps me.at gpm System Flow Rate.
Pool water volume 16,157 �360= 45 gpm-this Is the calculated flow rate
Note:for pools under 13,000 gals.the calculated flow rate or 36 gprn whichever Is greater the filtration flow rate Pump Selection as Listed on Curve A or C (circle one)
Is there an Auxiliary load on the filtratk)n pump? Yes X No
If so,what is the calculated auxiliary flow rate 96 gpm Filtration pump Maximum Flow Rate 140. gpm
STA-RITE INTELLIPRO VS
Flow Rate(low speed) 45 gipm @ 750 rpm.
Main Drain Cover [4QLJASTAR 32CDAV007
lin:mum suction side pipe size @ 6 fps 3_1n. Minimum suction side branch pipe size @ 6 fps-3__in. Determine the Number and Type of Required In-Floor Suction Outlets:
Min mum return side pipe size P 8 fps In. Minimum return side branch pipe size @ 8 fps 2 s in. Check all tha(apply.
(D 2 sucticin outlets @ gpm max flow
Determine Filter Size: 3 suction outlets @ gpnn max,flow
Filter Facws(GPWSF):M Cartridge(0.375) F]D E(2.0) Sand(15) IAQUASTAR -1 channel dram @ gpin W1 F2 ports
32CDAV007
Filter Size: 96 0,375 256'aax�'
fn�FKQ STA-RITE PLIVI 300 Total Head In Feet Conversion Chart Flow and Friction Loss Per Foot
Inches Memory(Vacuum Gauge) We"40 PVC Pipe
F-
o 1 2 1 1 1 0 1 6 10 1 12 1 11 1 19 16
Pump Controls 0 " 2S I 4A I U 1 9.0 Its IIS iu is, w Bm
r 16
Filtration pump has no auxiliary load-standard time clock I m 4A 1 al I ItA 13A I&A 14.1 94- d24T h� 21 927 IN
aW a "r
_NIA 4A IS I R1 1 11.4 It? 152 uL2 A4 _n.y er 0 Lis
Filtration pump with auxiliary load-Control model for law speed default within 24 hr. E!FNIAIR EASYTOUCH 3 - 7- 1 !as 1 i"i! - -
4 8.2 a 15.3 &A M 210 N.3 Ns 2N NMI a
5 IIJ I&A 'is r as Zu &W
&,3 - $is
US M
a, ZZA M 17A ao 382 ur
Heater Model STA-RITE SR4DO T %I W4 207 N2 US W Ns 343 US
84% W �7 ,Z V1 2" 3" U. M US
Gas Heater efficiency rating (No Pilot Light) NA 2V 1 2U VA 20A R.1 -NA -%S M 41wi TDH Calculation Options
Heal Pump efficiency C.O.P. N/A 10 2&1 25A I VA 292 VA XA X.7 NJ 41.2 43A FG-T-0-0 pump
11 21A VJ I NA = US X7 360 412 QA 46A
12 ".7 3u 1 = Us 3" WO 413 W 46A Q0 Checix one.
= I US 35A _iF_
13 IRS 1 413 "A W a, 90.4 SinVified Dramic Head STDH
14 M US US No 41A NA 452 WA 9 7 ET1 _Total _ _L J
IS US 35A N2 41A W NJ IV M Complete STDH Worksheel-Fill in at blanks
L " M 31L! 41A 4037 5" as ma 573 Total Dynamic Head(TDH)
-----F--il
DeleftnineSirriplifledMK ANSI 5&ANSI 7 Compliance Work Sheet is 41A 416--ftj NA .0 NO AFAI NA7 01-9 Complete Program or other caics Fill in required blanks on
T"V- 43"9- 1"1 E No 03
4 No 9 b?4 QL7 Ns N2 WGrkShe8t&attach calculations.
1. Distance from pool to pump in feet: 40 40Z W.? 634 65.1 6TS US Cis "A as
21 as ffl�_ 9.0 6&3 57S Sax Mi US US NA Maximum Flow Ca
2, Friction loss(I,suction pipe)IR 3 Inch*9 per I @ 181 gpin 0.07 (from plifie flow4rdon loss charq V WS 531 570 Us 82.1 NA %S fta ni of the new or repilacernem pump.
n MA 9, 57 7 WO W2 NA Ky US 712 713
24 65A W W. M2 US so.? us ru
�IA
Ns
.S
as NJ
su
s"
&'a
Us
A
3, Frictionlosagnreturnope)h 2.5 "Pipaparlit.@ 146 gpm 0.13 pipe Wirlodon loss died)
67.8 su SW .6 808 &1 113 73A M Mi
AD W.1 UJ US NJ No TIA T&A Iss Mi MCA
VA US&a" 6.2 11A T&T 76A AU WS 8-2.1
Z sas
TDH in Piping: 8 N 84.7 Im" W ?is no NS M2 is- NJ owner
n VS "3 TIA ra AW M3 ass 82A W1 V3 03.10.2017
Determine Simplilied TDH Filter I Heater IM in TDH 14.28 M emu NA ?a&B W Ns PFOTENHUAER
M I W Ka M 151 VA US
31 71S 73J MI nA K? 02 K2 97* W7 ZZ
:. Ns
32 T" 76.2 TBA 0.7- Me 8L2 VA- tr 9" 94.3
NS
4. 40 x 0.07 2.80 All other lom 1 N X2 M KT US N.3 VA NA WS 942 NA
34 ?9- NA WS
5. 40 K 0.13 5.20 35 SDI NO US 94A IftV I" 1M.2 CPC 1456979
Total Dymmic Head JDH�: WOTE:FED TDH MUST BE EQUAL TO OR HIGHER THAN THE
CALCULATED TDH. (924
�58-QO
Scale:None
The Association of
Pool& Spa Professionals'
ANSVAPSPACC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS
PROJECT NAME: PFOTENHAUER CONTRACTOR NAME CROWN POOLS INC.
AND ADDRESS AND ADDRESS:
1629 BEACH AVE 3002 PHILIPS HIGHWAY, JACKSONVILLE,
ATLANTIC BEACH, FL 32233 FL 32207
OWNER: PFOTENHAUER CONTRACTOR PHONE:(904) 858-4300 DATE: 3/10/2017
This information sheet was prepared by the APSP-15 Residential Swimming Pool and7pa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa
Professionals(APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only.Contractors should acquire and comply
with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org.
1. §5.2.1:Calculated pool volume
a. Gallons: 16,157 ;or 1. 16,157 gallons
b.Calculated Gallons: 432 (surface area)X 50 (average depth)X 7.48 (gallftA3) = 16,157
2.§5.2.1:Calculated maximum filtration flow rate 2. 45 gpm
(Pool volume-., 360 or 36gpm whichever is larger)
3.§5.2.2:Auxiliary Pool Load: PjYes, FjNo?
(Enter the highest"auxiliary pool load"to be powered by the swimming pool filtration pump.Do not odd auxiliary 3. 96 gpm
pool load flow rates together,only the highest is used.)
4. Calculated maximum flow rate 4. 96 gpM
(Item 2 or item 3, whichever is larger.)
5.§5.5.1:Pipe sizing:
a.Minimum suction pipe diameter 5a. 3.0 inches
(Enter the smallest pipe size from Table I with a 6jfpsflow capacity the some or more than item 4.)
b. Minimum suction branch pipe diameter 5b. 3.0 inches
(Calculate:Item 4. 96 (gpm) ., BronchPipes 1 (quantity)=branch flow rate 96 (gp_).
Enter the smallest pipe size from Table 1 with a 61ps flow capacity the some or more than the calculated
suction branch flow rate.)
c. Minimum return pipe diameter 5c. 2.5 inches
(Enter the smallest pipe size from Table I with a 8fpsflow capacity the same or more than item 4.)
d. Minimum return branch pipe diameter Sd. 2�5 inches
(Calculate:Item 4. 915 (gpm) ,Branch Pipes 1 (quantity)=branch flow rate 96 (gpm).
Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the some or more than the calculated
return branch flow rate.)
6.§5.4.1:Filter type and size:
a. Filter type:(Cartridge, DE,Sand) 6a. Cartridge
b. Minimum filter area 6b. 256.0 sq.ft.
(Calculate:item 4. 96 (gpm)-�filter factor 0.375
Filterfactors:Cortridge=0.375, Sand=15,Diatomaceous Earth=2
7. §5.4.2:Backwash valve: E]Yes, El No? 7. 2.5 inches
(When using a bGckwash valve,enter result of item 5c or 2 inches whichever is larger)
Table 1 Pipe Size: 1.5" 2- 2.5" 3" 3.5- 4" 5. 6"
Nominal GPM @ 6 fps 38 63 1 90 138 185 238 374 540
Nominal GPM @ 8 fps 51 -711 1-19 184 1 247 1 317 499 720
8. Pump selection:
§S.3.2.1.Pools 17,000 gallons or less,select pump*from the database with a Curve-A gpm flow equal to item 2 or less.
§5.3.2.2:Pools 17,001 gallons or more,select pump*from the database with a Curve-C gpmflow equal to item 2 or less. *Multi-
speed pumps must have one speed listed that satisfies this requirement.
a. Pump model 8a. STARITE INTELLIPRO VS
b. Pump flow 8b. 75 gpF11
(§5.3.2.1,5.3.2.2:Applicable Curve A or C gpm flow listed in database)
4/4/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 1 of 2