482 Mako Dr - ACC18-0017 CITY OF ATLANTIC BEACH li F�J � > 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ACCESSORY - SINGLE OR TWO FAMILY ACCESSORY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ACC18-0017 Description: POOL HOUSE ADDITION AND RENOVATION Estimated Value: 120000 Issue Date: 4/23/2018 Expiration Date: 10/20/2018 PROPERTY ADDRESS: Address: 482 MAKO DR RE Number: 171480 0000 PROPERTY OWNER: Name: JAMES WEST Address: 482 MAKO DR ATLANTIC BEACH, FL 32233-3906 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: HORN BUILDERS INC Address: 12215 St. Johns Industrial Parkway North CHARLES R HORN Jacksonville, FL 32246 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. JS - Ssl Conditions ofAtlanticBeach Permit Number:ACC18-0017 Description: POOL HOUSE ADDITION AND RENOVATION Applied:3/5/2018 Approved:4/17/2018 Site Address:482 MAKO DR Issued:4/23/2018 Finaled: City,State Zip Code:Atlantic Beach, FI 32233 Status: ISSUED Applicant:<NONE> Parent Permit: Owner:JAMES WEST Parent Project: Contractor:.<NONE> Details: LIST OF • • SEQ NO I ADDED`DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 3/7/2018 EROSION CONTROL INSTALLATION INFORMATIONAL PUBLIC WORKS Scott Williams s .. Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Une-(247- 5814).to request an;Erosion and Sediment Control Inspection prior to.start of construction. 2 3/7/2018 ON SITE RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes All runoff must remain on-site during construction. 3 3/7/2018 POST CONSTRUCTION TOPO INFORMATIONAL SURVEY PUBLIC WORKS Scott Williams Notes. M x a+ If on-site storage is,required,a postconstruction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. 4 3/7/2018 ROLL OFF CONTAINER INFORMATIONAL PUBLIC WORKS Scott Williams Notes:: Roll off container company must be on City approved list"(Advanced,Disposal,Realco Recycling,Shapell's,°Inc.,Republic Services,Donovan Dumpsters). Container cannot be placed on City right-of-way. ; 5 3/7/2018 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including`sod,is required: Printed: Monday,23 April,2018 1 of 2 lip �i�S'`311�Irj�n r ¢` J Conditions City j.0 of 6 3/7/2018 RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Ali runoff must remain;on-site. Cannot raise lot elevation. 7 3/7/2018 CIRCULAR DRIVEWAY INFORMATIONAL PUBLIC WORKS Scott Williams 6 Notes:. Circular driveway notallowed. 83/7/2018 ADDITIONAL COMMENTS PUBLIC INFORMATIONAL WORKS PUBLIC WORKS Scott Williams 'Notes: � Per Section 19-7(f)of the City code,circular driveways are only allowed with a 100'frontage. qovPrinted: Monday,23 April,2018 2 of 2 VA Sig IW. �yy City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) r 800 Seminole Road 1 J Atlantic Beach, Florida 32233-5445 �` �` —0c) I Phone (904)247-5826 • Fax(904)247-5845 •�„pis' E-mail: building-dept@coab.us Date routed: _ l C, City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM ProperAddress: D _went review required Yes. No Applicant: B DI Planning &Zoning Tree Adminis rator. Project: l, O's 6L, ublic Works n Public Utilities C� cPublic SaC)v. /,7c ' G� e y Fire Services ,Review fee^$. -� Dept Signature ipt Other Agency Review or Permit Required Review o eri fi e of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Diy'iSion of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco 4 Other: �t 05 APPLICATION STATUS Reviewing Department First Review: ❑Approved.. Denied. ❑Not applicable (Circle one.) Comments: PLANNING &ZONING Reviewed by: Date: eb P— TREEADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. [—]Not applicable. PUBLIC-WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: .FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 �� � `Building Permit Applicati®n Updated 12/8/17 *_ O rl �� COQ City of Atlantic Beach 800 Seminole Road,Atlantic Beach,FL 32233. Phone:(904)247-5826 Fax:(904)247-5845 Job Address: I ®x302 ,(VIy-ems Permit Number: Legal,Description,-ok 11C 6 ?6-rt ��m0 ��,�� RE# tJ�..w.tt Valuation of Work(Replacement Cost)$ ,Z)C50 Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle one): New dditio Alteration Repair. Move Demo Pool Window/Door • Use of existing/proposed structures)(Circle one): Commercial Residentia • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed:. 1 Florida Product Approval# for multiple products use product approval form Property Owner Information Name: So` -cs Wt. Address: City C, RC_ Al State &-4 Zip 32-233 _ Phone d SZS- �o2e1c1 E-Mail 63s G.:a Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information aa Name of Company: ��1P'Yl ����CA2fS Qualifying Agent: AddresszlSS�.�o�..nS�int�u Y;wA M W rP City-�cr satrvi�k. State 'FL Zip 2-2,40 Office Phone- q��{ 24Z-?�'A� Job Site/Contact Number a State Certification/Registration# GCyG`aS%CC60 2, E-Mail Architect.Name&Phone# :S-U. I G �n�- 'ZZsV-*_rb 4 9ZH 70 - S62.19 Engineer's Name'&Phone# Workers Compensation Exemp /Ins er/Lease Employees/Expiration Date. Application is hereby,made to obtain a permit to do the work and installations as.indicated. I.certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the'laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS,.FURNACES,BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,et . NOTICE: Ln addifion to fhe requirements of thi permit,there may be additional restrictions appl¢ablefto this«property that may be found in the public records of this county,an here ma be a'ZU onal •ermi�ts re aired from other oacernrriental entities such as water masa ernen-t districts,state a envies,o ederal agencies OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. .. .WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE°OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCINGVICE , CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE -RECO N YOUR WOC 7MMENCEMENT. (Signature of Owner or Agent) (Signature of Contractor) (including contractor) T r Signed and sworn to(or affirmed)before me this S day of Signed and sworn to(or affirmed)before me this 1 s day of _MA20.k Zai r ,by 3,A"gs Desi M#1¢tH 2011 by Clea-(CS ytb2da (Signature of Notary) (Signature of Notary) Personal) o� .�Av PATRICK RICH Y KnownOR r .•••,� [Personally Known OR i21CH Commission#GG 137126 PATRICK ]Produced Identification+ * [.]Produced Identification Prov p., Expires September 15 2021 .•"'• Commission#GG 137126 Type of Identification: 4.9 2091 o Type of Identification: Expires P. . . a��Off��P goodedTlWBud9�HotNYs uiECY PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes:6th dition (2017) Florida Building Code Ao/ OV S-e_ DEVELOPMENT SIZE: Habitable Space (ft2) q4 V Non-Habitable Space (ft2) LAND INFORMATION: Zoning District 12.f `-7 Flood Zone X Minimum FFE BUILDING INFORMATION: Construction TypeU Occupancy Group Si-gjf ram,, ly Number of Stories Max Occupancy Load Fire Sprinklers Required CONDITIONS/ COMMENTS: Rev. 2.7.2018 `�► CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach Florida 32233 ; _ Y REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS '� Date � Revision to Issued Permit Corrections to Comments_ Permit# ��L d —b® d Project Address 4 Contractor/Contact Name Phone Z47,-- o 0 Email Description of Proposed Revision/Corrections: Peri ee Due$ 5-0- 040) RAIP--S' tErtk) Jjul Additional Increase in Building Value $ Additional S.F.. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed naine) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved n Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: nnin &Zonin Reviewed By Tree A ' istrator Public Safety Date Fire Services { CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD OFFICHOPY ATLANTIC BEACH FL 32233 (904)247-58.00 BUILDING REVIEW COMMENTS Date: 8 - ![1-jeodries• ,• �,; Review Status: RE#: 171480 0000 Applicant: HORN BUILDERS INC Property Owner:JAMES WEST Email: CHUCK@HORNBUILDERS.COM Email: bch32233@aol.com Phone: 9042422600 Phone: 9045256299 9044169998 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. euisions may not be submitted until ALL departments have completed their respective reviews Revisions submitted MUST respond to EACH department review.Submittals that respond to only one or ew correction items wil not be accepted Correction Comments: 1. - mg e ance . 2. a e symbol over the shower in the pool house is a combo light/fan. The symbol is not in the tea^ 3. �Io sec ions - a e perms or a r r. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 904.247.5 844 Email:mjones@coab.us • LClI ho 41 IQev;,e w Cpm mP ev tote `ate; Resubmittal Notes: City of Atlantic Beach APPLICATION NUMBER BUllding Department (fo be:assigned bythb Building Department.) 800 Seminole Road _Atlantic Beach, Florida 32233-5445 . Phone(904),247-5826 Fax(904)247-5845 rytp E-mail: building:dept@coab.us Date'routed: L City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING: FORM Property Address: � � �c K0 QqpaftWent review required Yes.- No (( Buil Applicant: l r Tree-Admmis rator Project: ublic Works (n Wil.-, oz� - _ Public:Utilities ©lV\ �_D0\1 t C-' F\_� Public Sa efy.., Fire Services Review feed$:' Dept Signature. -� - Review or Receipt Other Agency Review or Permit Required of Permit Verified By . Date Florida Dept.of Environmental Protection Florida Dept.of Transportation 4 St.Johns.River Water Management District Army Corps of Engineers . .. �✓ ` Division of Hotels and Restaurants `�• Division of Alcoholic Beverages and Tobacco Other, APPLICATION STATUS Reviewing Department First Review: ❑Approved.. /21D , _ QNot applicable Circle one.)) Comments: �1 BUILDI N G JJ rflq\+7 . PNIN`G &AZO NSG Reviewed by: ��� Date: -- TREE ADMIN. Second Review: A roved:as revised. Denied. . 0 pp ) Not applicable PUBLIC WORKS Comments �C r n e�wect� 1'!PL�ye .Feel PUBLIC UTILITIES -P�5iexf-e Q PUBLIC SAFETY Reviewed by: ,�fe, Date: 7 1 V FIRE SERVICES Third Review: .Approved as revised. ❑Denied. QNot applicable Comments: /moo✓ecl V . Giak '/tee Reviewed by: 4� Date: Revised 05/19/2017 1 CITY OF ATLANTIC BEACH 800 Seminole Road y Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date Revision to Issued Permit Corrections to Comments_ Permit# C C;' `d d d Project Address ``I- Contractor/Contact Name c) Phone Z4-z— Z 620 0 Email Description of Proposed Revision/Corrections: Permit Fee Due$ Additional Increase in Building Value $ Additional S.F.. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied ( Not Applicable to Department Revision/Plan Review Comments �eee li; �" I s �Jc/ Department Review Required: 2n, inReviewed By Z Tre strator Public Safety Date Fire Services TREE VEGETATION AFFIDAVIT City®f Atlantic Beach Department of community Development Planning&Zoning Division 800 Seminole Road Atlantic Beach, FL 32233 (P)904 247-5800 (F) 904 247-5845 PERMIT SECTION I-APPLICANT INFORMATION Owner(s) r Legal Authorized Agent* NAME OF APPLICANT J NAME OF COMPANY , / �- ADDRESS OF COMPANY G lz6 � f �� �� r Q VVh�// n f1l� , { PHONE �(y�' I Z7� � CELL �"l �- G�f�(� EMAIL 19 CONTRACTOR CERTIFICATION NUMBER ATLBCH BUSINESS TAX RECEIPT NUMBER SECTION II-SITE INFORMATION STREET ADDRESS OF PROPERTY 45 If an address has not been assigned to this property,contact the AB Building Department at(904)247-5826 to request an address. LEGAL DESCRIPTION 1 L n r Gt — — LOT 1 BLOCK SUBDIVISION REAL ESTATE NUMBER LOT OR PARCEL SIZE: SQ FT AC RESIDENTIAL x COMMERCIAL OTHER(SPECIFY) .. .... _ .__.._.. _ . . ... 1 affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation"of the Municipal Code of Ordinances for the City of Atlantic Beach,FL and/or I have participated in a pre-application meeting with the Administrator of those regulation . Subsequently,I affirm that no regulated trees and no regulated vegetation will be damaged,destroyed and/or removed fro the ove-described or adj 'e pr tie ' conjunction with this project. SI AUR OF O NER SIGNATURE OF OWNER Signed and sworn before me on this day of z arQ ,by State of �L -� •cs Wesr County of Identification verified: Oath sworn: r Yes No S [ Notary Signature N.,, PATRICKRICH Commission#GG 137126 RE4l_TVA-v 10.12 My Commission expires: "0,,�7 F.xpiresSep �r15,2021 Ht+n7xJTluuBt MAP SHOWING SURVEY OF I I a LOT 11. BLOCK 13, REPLAY OF PART OF ROYAL PALMS UNIT TWO A, AS 11 RECORDED ION PLAT BOOK 31, PAGES 16, 16A THROUGH16D OF THE II CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. LaJ J Q U In I } I I I L 0 T 12 1 , I I I N82'44'09'E 92.96' FIELD I F0UNO I/2.'RON - 93.00' I PIPE SAP I 'FOO1 fIZ IRON N82°43'58"E a. prof'No CPP I ¢' 6'CIINN UK FQ10E >I . I 5�I O 0 K'Ooo FENCE 1 W ^'•I 15' 1 n' 1 I . � � iowc1E pwv€°. ;o 0 Z I m coNC�REIE CARPORT ::. J o / LOT 16 z01a[ I� 25.1' , --Z m � j I T 1p P N 2 C) m f N m of I� N N �� CI 00 7 p J 00.I Ic h�_ :', 8 61 1 ro p IC �2 I "I 1 25.1' UE 80K e G ' AWooO FENCE 4. o 09 i a FOUND I/2 NC SCAR I o,1' 6•a1NN LINK FENCE - FouNp 3�< IRON 582'43'58"w 93.00 153uL , pIpE1, GAP , . L 0 T 17 1 I - �i I LOT 10 7-C) n I C _ c- :• NOTES: I. THIS IS A BOUNDARY SURVEY. 2. BEARINGS ARE BASED ON THE WESTERLY RIGHT OF WAY LINE OF MAKO DRIVE A 60' RIGHT OF WAY BEING SOUTH 0716'02" EAST AS PER PLAT. 3. BUILDING RESTRICTION LINE AS PER PLAT. 4. EASEMENT AS PER PLAT. THIS SURVEY WAS MADE FOR THE BENEFIT OF THE PROERTY SHOWN HEREON APPEARS TO LIE TREY AND TARA HATCH; CHASE MANHATTAN MORTGAGE CORPORATION; COMMONWEALTH IN FLOOD ZONE "X" AS WELL AS CAN BE LAND TITLE INSURANCE COMPANY; BUSCHMAN, DEETERMINED FROM THE "FLOOD INSURANCE AHERN, PERSONS & BANKSTON RATE MAP" PgNEL NUMBER 120075 0001 D, REVISED APRIL 17, 1989 FOR ATLANTIC BEACH FLORIDA. "NOT VALID MTHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. DONN W. BOATWRIGHT, P.S.M. FLORIDA LIC. SURVEYOR and MAPPER No. LS 3295 CHECKED BY: FLORIDA UC.SURVEYING&MAPPING BUSINESS No. LS 3672 DRAWN BY: FHC BOATWRIGHT LAND SURVEYORS, INC. FILE: 2DO* 0939 DATE: 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 — JULY t 9nne SHEET�OF� ASC PND 6 FLITUR L E01:1P ® FOOL HOUSE C? SUfJ�I�iER N I I KITCHEN c \/ 10" o FUTURE N i POOLco EXISTING ui �rVi "' RESIDENCE a ' . a LOT COVERAGE,- NEW TOTAL LOT 7,500 S.F. DRIVEWAY EXISTING HOUSE 1,267 S.F. NEW ADDITION 136 S.F. NEW POOL HOUSE 636 S.F. NEW DRIVEWAY 1288 S.F. FRONT PORCH & WALK 94 S.F TOTAL IMPERVIOUS 3,421 S.F. (45.61%) MAKO DRIVE-.80.65' PROPEH'0TY LINE � Tl N c" ITE f; j-���', 1� `1 SCALE: i/16 = 1'-0" ` ��� � � Pi 0111(\ -+-:+--:�:a't'�il:S.:L�xiv'tL4:el::•u,.La.ua'._LSL':u��]i:i�_i':K Z•.':�1:'.'h'�:':'_:••.^•..c.(..�•:T-T:f:::;l'.a'1_:,:"+' "`�-''""' n-/3)fIIiQ.ul'1¢'Y.CN'tlYrf(�y�gWILu3R•trm.rw.,.-.: ' \''JNIyiO![p➢,n,Rllf.lei^.PlGJ.'Si1rnCv'�.'::✓l�Y!:4'.J:WISUL::Iu)1'UN4T.�•U•�NA911(l1CSIS911aL•[L'9'lu'1IILTu(TLC;•JfflMlP1.,'lii'1Nff11'r1M4"Y,ti-1:1/J:iLYIi^NIl:Q6n.F„"l�iS[f1r5N'e CITY OF ATLANTIC BEACH 800 Seminole Road r� Atlantic Beach,Florida 32233 "�J.fl>f• REVISION REQUEST/CORRECTIONS TO PIAN REVIEW COMMENTS Date'— Revision to Issued Permit Corrections to Comments Permit# P� �L®j"r�o Project Address Contractor/Contact Name Phone�6 �Z� � Email r Q U CSI Lon Description of Proposed Revision/Corrections: Permit Fee Due$ 1 • I !''e� Ylr1���T��1 ��1 ��O W 1 Irl C \�J �/, ��'�.e� '�� S 1�� �'�'.v� (Ae p(cu\ s Additional Increase in Building Value$ AdditiouAS.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: uildin� - y IT ning &Zoning�" Reviewed By ree Adminis ra or 1 f OiMty- i�PubDate Fire Services Cit of Atlantic Beach APPLICATION. NUMBER` #% City ; . �i Building Department .% (Tobe assigned by the Building Department.) °1 MAR 6 5 201$ 800 Seminole Road I" ii m Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-584 E-mail: building-dept@coab.us Date routed: t . City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: -) Rz) -Qopartment review required Yes No Buil Applicant: �� ('7 nning &Zoning r Tree Adminis rator Project: PnnL- (���, -c- -)W ublib ,or,Rst _ ) Public Stl lities EAD ND 0 V P7( (D r=v Public ae y­5 Fire Services Review fee $ Dept Signature. ; Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers (� Division of Hotels and RestaurantsG. Division of Alcoholic Beverages and Tobacco Other: �l 05� APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by,, Date: �-� TREE ADMIN. Second Review: A roved as revised. Denied. pp ❑ ❑Not applicable -.F.U.BLIC-WORKS== - Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 CITY OF ATLANTIC BEACH Department of Public Works 1200 Sandpiper Lane = Atlantic Beach, FL 32233 (904) 247-5834 PUBLIC WORKS PLAN REVIEW COMMENTS Date: 3/7/18 Applicant: Horn Builders Permit#: ACC 18-0017 (DENIED Pool House/Renovation) Address: 11215 St. Johns Industrial Pkwy.N. Site Address: 482 Mako Road Jacksonville,FL 32246 Email: bch32233@aol.com APPROVED Email: chuck@hornbuilders.com PUBLIC WORKS CORRECTION ITEMS: a (Submit the following to the Public Works Department in order for us to approve your application) • Provide drainage plans showing site topography (flow arrows, etc.). • Section 24-66(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 400 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-66(b). • Provide a pre-construction topographic survey prepared by a Florida Licensed Professional Land Surveyor, showing 1' contours. • Provide a detailed plan of water retention area and how water runoff gets to water retention areas and then to street. • Per Section 19-7(f) of the City code, circular driveways are only allowed with a 100' frontage. PUBLIC WORKS CONDITIONS OF APPROVAL: (The following comments will be printed on your permit as Conditions of Approval) • Full erosion control measures must be installed an approved prior to beginning any earth disturbing activities. Contact the Inspection Line (247-5814)to request an Erosion and Sediment Control Inspection prior to start of construction. • All runoff must remain on-site during construction. • If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. • Roll off container company must be on City approved list (Advanced Disposal, Realco Recycling, Shapell's, Inc., Republic Services, Donovan Dumpsters). Container cannot be placed on City right-of-way. • Full right-of-way restoration, including sod, is required. • All runoff must remain on-site. Cannot raise lot elevation. • Circular driveway not allowed. • Per Section 19-7(f) of the City code, circular driveways are only allowed with a 100' frontage. Page 1 of 2 Scott Williams,Director of Public Works swilliams(i�coab.us /904-247-5834 THIS PLAN REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS ny plan cliange must be submitteda's aRevisoton t®,theuBtail'cing Department at 800 Seminole Road evisrons=. ay�notbe�siabrritt�cl until P►I��L`depa"rtm ns�haue completed their respective reviews. signs swbmitted M115T�respond to EACH department review► ub �ttals�that�respond,to only ne�or�afe�nra correction items. gill not be ecce ped Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. Page 2 of 2 22'-0" 12'.0" C AIC PAD 6n FLFTuR L EQUIP (ye CD POOL CN U-j )Fr A s,' t HOUSE < < C? L'UTIC H E fl, (D 12'-0" 3V-10" to r- ed '14'-4 E FUTURE M POOL co ui R�r k'l Op EXISTING z RESIDENCE :1 Y, uj LOT COVERAGE: NEWfl DENIED TOTAL7,500 S.F. 9 DRIVEWAY EXISTING HOUSE 1,267 S.F. NEWADDITION 136 S.F. NEW POOL HOUSE 636 S.F. NEW DRIVEWAY 1288 S.F. 101-01, FRONT PORCH & WALK 94 S.F. ang` -f-ce- 10'-0" TOTAL IMPERVIOUS 3,421 S.F. (45.61%) MAKO DRIVE--80,65' P-ROPE� TY 1jrIL- EXISTING't 01TE 1 "LAN SCALE: a Y)CO yn Pi�Y\ fV y r CITY OF ATLANTIC BEACH APR 03 2018 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date Z Revision to Issued Permit Corrections to Comments_ Permit# d b o Project Address `moi / �i Qo� Contractor/Contact Name H RAo L Phone Z47,-- z ©0 Email Description of Proposed Revision/Corrections: Permit Fee Due $ LO S [-cc- Additional "EAdditional Increase in Building Value $ Additional S.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: uil ' nnin &Zonin a 'ewe y Treer .istrator Public Safety Date Fire Services Comp. By: SM Date: 4/2/2018 Public Works Department City of Atlantic Beach Permit No: ACC 18-0017 Address: 482 Mako Road Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion,and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predeveloament Runoff Volume: Lot Area(A) = 7,500 ft' Runoff Coefficient Area Lot Area Description (ft) (ft) "C" Wtd"C" Impervious 1,845 7,500 1.00 0.25 Pervious 5,655 7,500 0.20 0.15 Runoff Coefficient(C)= 0.40 Runoff Volume V= 0.40 x 7,500 x 9.3 / 12 V= 2,306 ft3 Postdeveloament Runoff Volume: Lot Area(A) = 7,500 ftZ Runoff Coefficient Area Lot Area Description (ft) (ft) "C" Wtd"C" Impervious 2,925 7,500 1.00 0.39 %ISA= 39.0% Pervious 4,575 7,500 0.20 0.12 Runoff Coefficient(C)= 0.51 Runoff Volume V= 0.51 x 7,500 x 9.3 / 12 V= 2,976 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume-Predevelopment Runoff Volume DV= 2,976 - 2,306 DV= 670 ft3 Retention Mako 482 4/2/2018 `# K Comp. By: S/W ' Date: 4/2/2018 Public Works Department City of Atlantic Beach Permit No: ACC 18-0017 Address: 482 Mako Road Provided Storage: Elevation Area Storage (ft) (ft) (ft) 10.5 216 0 BOTTOM size 18 X 12 11.0 280 124 TOB size 20 X 14 Elevation Area Storage (ft) (ft) (ft) 0.0 0 0 BOTTOM 0.0 0 0 TOB Elevation Area Storage (ft) (ft) (ft) 0.0 0 0 BOTTOM 0.0 0 0 TOB Inground storage=A*d*pf A=Area= 280.0 d=depth to ESHWT= 7.5 pf=pore factor= 0.3 Inground Storage= 630.0 ft3 Required Treatment Volume= 670 ft3 Supplied Treatment Volume= 754 ft3 �uY, 1 Retention Mako 482 4/2/2018 �t 0 . rm - CITY OF ATLANTIC BEACH 800 Seminole Road J Atlantic Beach,Florida 32233 APR � 12010 '��J,3l�r" � ji �,I-• ' REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date —)C�--) 1� Revision to Issued Permit Corrections to Comments Permit# 8 W V 0 Project Address Contractor/Contact Name G�yn�C3��fs Phone 9 6 �2 c� �� Email Description of Proposed Revision/Corrections: Permit Fee Due$ r2-, V C Q Additional Increase in Building Value $ Additio S.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments lal7s'fcD �a�9 2'rDZ�(-�CYt�i Department Review Required: uildin� rnng &Zoning Reviewed By Tree Adminis ra or rW7bWt-v- (- s i iAVPuate Fire Services Pity of Atlantic Beach 'APPLICATION'NUMBER Building Department, (To be as1ci ned b tihe Buildingartrrient. Atlantic Beach, Florida 32233-5445 De p ) c� 9 y F s 800 Seminole Road Phone(904)247-5826 Fax(904)247-5845 E-mail: building-dept@coab.us D to routed:' _ City web-site: http,//www.co8b.U8 APPLICATION REWEW r�D-T`RACIONG: FORM Pro a Address: is P-epadWent review required Yes No Buil ' Applicant: � `�; (�11�� � ening &Zoning Tree Adminls rator: Pro : ublic 1Norks J ��1 Z_ 0� , _ �PubiiciU;ti6tiesx; I�I0.MG o C)V, lLC, r PublicSaTe-Cy " Fire Services Review fee$ Dept Signature + '� Other Agency Review or Permit Required Date Review or Receipt of Permit Verified By Florida Dept.:of Environmental Protection Florida Dept. of Transportation 4 St.Johns:River Water Management District Army Corps of Engineers Division of Hotels and Restaurants . Division of Alcoholic Beverages and Tobacco Other:: APPLICATION STATUS Reviewing.Depar.t..ment First Review_: ❑Approved._.. ODenied. applicable (Circle one.) Comments: BUILDING PLANNING &ZONING 00, ( �v Reviewed by: Date: 3 a TREE ADMIN. Second Review: A roved:as revised. 0 pp ❑Denied. QNot.applicable; PUB WORK Comments:. � BLI'CUmTILIESx PUBLIC SAFETY Reviewed by: - Date: FIRE SERVICES Third Review: QApproved as revised. ❑Denied. ONot applicable Comments: Reviewed by: Date: Revised 05/19/2017 APR 0 3 2013 � �f r CITY OF ATLANTIC BEACH a� 800 Seminole Road q } Atlantic Beach,Florida 32233 REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COMMENTS Date Revision to Issued Permit Corrections to Comments_ Permit# d _00 1 Project Address ``I` Contractor/Contact Name Phone Z 4-Z_ Z 6 0 Email Description of Proposed Revision/Corrections: Permit Fee Due$ nz a v Additional Increase in Building Value $ Additional S.F. By signing below;I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Departmenty Revision/Plan Review Comments Department Review Required: uil nnin &Zonin Reviewed By Tree A ' istrator Public Safety Date Fire Services I CITY OF ATLANTIC BEACH P - A �� 800 Seminole Road PR 20ki C+ Atlantic Beach,Florida 32233 LAY REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date4– Revision to Issued Permit_ Corrections to Comments'X' Permit# l���o-Do I Project Address 4 Contractor/Contact Name Phone'�6 �2 c� �o� Email Description of Proposed Revision/Corrections: ( Permit Fee Due $ -W/ 7�y -f—f'S S �k 2 � a Additional Increase in Building Value $ Additio�ak. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department V Revision/Plan Review Comments -* P IMS'bD IArg' 'b Lzy-t CW' Department Review Required: !uildi AAf—, ning &Zoning Reviewed By Tree Adminis ra or Pubic ety--- Date Fire Services l OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR T FIE CITY OF A�LAI�ITIC BEA_CII.FLORIDA Project Name: \AIQS�- Permit # f, F— Project Address: 49L MGiko Ia e,�� ;c P-9,c,� r2— 3 LZo? _ As required by Florida Statute 553.542 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide roduct approval may be obtained at: www.floridabuildin . KMg. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4.8611 sup'< 1_ `OX7 Z2:520 _ - 5. Automatic � 6. Other B. WI7D—OWS 1. Single hung ,I �l a� ���� �� J FL 2. Horizontal slider 3. Casement � -- 4. Double hung 5.Fixed 6.Awning �...7. Pass-through 5. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL.WALL. 1. Siding 2. Soffits ILI 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other QA, �1, o, D.ROOFING PRODUCTS 1. Asphalt shingles , S QFL I 2. Underlayments 3. Roofing fasteners 4.Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 1 l. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof the adhesive 16. Spray applied polyurethane roof NFICE CO 17. Others _.. ._ __ __�v�. - -- _,____ - 9- @ Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E. SHUTTERS 1. Accordion 2. Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F. S'T'RUCTURAL COMPONENTS 1. Wood connector/anchor 2. Truss plates FL Jo 3. Engineered lumber s` ��---o 4. Railing M SIAZ 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other O. SKYLIGHTS 1. Skylight .�_._.a..-�...�........,W,..: .�..�..,..-._... __,_- -- - _.....,._.�,._...._,....__ �._..�... 2. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# H. NEW EXTERIOR ENVELOPE PRODUCTS 1.� In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) II (Print Name) (Signa ure) Company Name: t Mailing Address: City: D'e.c v,a�nt �e, State: Zip Code:_ ��— Telephone Number: (0�J Fax Number: (`® Cell Phone Number: (904) Vz(0_zW4 E-mail Address: L"� u' OFFICE COPY 482 Mako Dr HVAC Load Calculations for RHV A. . d1aQA . ` -C Prepared By: Alexa Laughren Monday, March 19,2018 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. Rhvac Residential Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Seances.:. W w.,. ._ _ 482.._; Mako Dr. Manual S Performance Data - System 1 - System 9 :Conlin ..Loads.and`D.esi n_Conditi'ons Outdoor Dry Bulb: 95 Sensible Gain: 12,259 Outdoor Wet Bulb: 77 Latent Gain: 2,228 Indoor Dry Bulb: 75 Total Gain: 14,487 Indoor RH: 50 Load SHR: 0.85 Elevation: 26 Supply Airflow: 445 Latitude: 30 Entering Dry Bulb: 80 Altitude Factor: 1 Entering Wet Bulb: 64.6 ,Eui"ment•PerformanceDataat_.S sferriD-esi n:Conditions° .'_:: - ' Air Source Heat Pump Model:25HCE418A*030*+FB4CNP018L, Nominal Capacity: 17,800 e_ Interpolation D �. .a_ .EDB I. Total { Power + 79.9 OF EM i Air Flow ODB Capacityj :Input °F CFM :I °F { Sensible' MBtub. li ,kW }• I Srl Capacity I I j i MBtuh 85 17.1 1.35 0.696 11. 52 27 %- ."1.05 15.16 1.73 0.731 11.0 63 r 65 17.75 1.38 0.755 13.41 67 15.66 1.75 0.801 12.5 85 18.48 1.36 0.67 12.3 52 1 , 105 16.4 1.73 0.706 11.5 67 85 19.15 1.38 0.732 14.01 105 16.91 1.76 0.778 13.1 Interpolation Results: Percent LQad. of Load Sensible Capacity: 12,455 12,259 102% Latent Capacity: 4,490 2,228 201% Total Capacity: 16,945 14,487 117% Power Input: 1.55 C:\Users\donovanuser\Documents\Energy Sheets\482 Mako Dr\482 Mako Dr.rh9 Monday, March 19,2018, 11:50 AM khvac Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Sennces_,_ ,. .....482 Mako Dr .Jacksonville FL 32218 - Pa a 3. Manual S Performance Data - System 2-- System 2 ..Coolie' :Loads.and'Desi n.Conditions. . _ .:.._:- Outdoor Dry Bulb: 95 Sensible Gain: 6,995 Outdoor Wet Bulb: 77 Latent Gain: 817 Indoor Dry Bulb: 75 Total Gain: 7,812 Indoor RH: 50 Load SHR: 0.90 Elevation: 26 Supply Airflow: 303 Latitude: 30 Entering Dry Bulb: 76 Altitude Factor: 1 Entering Wet Bulb: 62.9 E ui ment Performance.Data.at.S stem De§i n„Conditions, _ Air Source Heat Pump Model: MUZ-HM12NA2***+MSZ-HM12NA***, Nominal Capacity: 12,000 -Enter d lation Data: Tofal' ;I Power 79.7°F .EWB' i Air Flowl QqB.!� I - -- - °F CFM” °F ± Capacity({{ Input _ i Sensible i I MBtuli il, kW SIT I_ Capacity y I i k MBtuh 63� 85 9.1 0.66 0.956 8.7 1:Q.5 7.7 0.77 0.948 7.3 V I 32.2, .� j _85 9.7 0.69 0.825 8 67 f . l 7105, 8.4 0.8 0.821 6.9 Interpolation Results: Percent Laacl_ of Load Sensible Capacity: 7,780 6,995 111% Latent Capacity: 880 817 108% Total Capacity: 8,660 7,812 111% Power Input: 0.73 C:\Users\donovanuser\Documents\Energy Sheets\482 Mako Dr\482 Mako Dr.rh9 Monday, March 19, 2018, 11:50 AM Rhvac-Residential&Light Commercial HVAC Loads Hite Software Development,Inc. Home.Energy Services _- 482 Mako Dr Jacksonville FL_32218 Page 4 System I Room Load Summary Htg Min_ Run Run ClgClg -Min Act Room Area_ Sens Htg ,: Duct Duct Sens:,. Lat Clg, Sys` No Name SF_ 'Btbh :._:���CF.M�::� � 'Size" �:,CFM Vel`.. !B:tuh,._ _ Btuh -_ CFM ---Zone 1--- 1 Master 600 10,380 210 5-6 454 9,787 1,304 445 445 Bedroom/Bath Duct Latent 269 Return Duct 702 2,472 655 System 1 total 600 11,082 210 12,259 2,228. 445 445 System 1 Main Trunk Size: 12 in.- Velocity: n.Velocity: 567 ft./min Loss per 100 ft.: 0.080 in.wg Coolin• 8y.st'611,86mmiry Cooling Sens ble/Lat 'nt - Sensible Latent Total, ` Tons S lit_` -Btuh , Btuh___ Btuh. Net Required: 1.21 85%/15% 12,259 2,228 14,487 Actual: 1.48 75%/25% 13,350 4,450 17,800 E ui merit Data - •-- - --._.. . -- -. - _.• . _'. _ _ -Heating system Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HCE418A*030* 25HCE418A*030* Indoor Model: FB4CNP018L Brand: CARRIER CARRIER Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 8.2 HSPF 14 SEER Sound: 0 0 Capacity: 17,600 Btuh 17,800 Btuh Adjusted Capacity: n/a 16,945 Btuh Sensible Capacity: n/a 13,350 Btuh Adjusted Sensible Capacity: n/a 12,455 Btuh Latent Capacity: n/a 4,450 Btuh Adjusted Latent Capacity: n/a 4,490 Btuh AHRI Reference No.: n/a 9671302 C:\Users\donovanuser\Documents\Energy Sheets\482 Mako Dr\482 Mako Dr.rh9 Monday, March 19, 2018, 11:50 AM khvac Residential&Light Commercial HVAC Loads Elite Software Development,Inc HomeEnergy Services _.. _ 482 Mako Dr acksonville FL 32218,', S sfem 2 Room Load Summaty Htg Min Run.° CIg Cl' g Min Acte Room AGea., Sens Htg ` Duct Duct Sens Lat Cl.g S"ys :8F-- .. .Btuh , , `CFM, _ Slze ._ Vel'. :Btuh , Btuh";`. CFM CFM. ---Zone 1--- 2 Pool House 258 4,218 85 3-6 515 6,662 671 303 303 Duct Latent 49 ..........__..... Return_Duct.._.___...____................._._.---_159 .-._ ._._. _._333..----.____....------98............ __..__System 2_total __.. 258 4,377 85_.._ 6.995 817 303303_ System 2 Main Trunk Size: 10 in. Velocity: 556 ft./min Loss per 100 ft.: 0.098 in.wg 'i✓oolin�;:S stern Summar _ _���. % Cooling S`ensiblelLatent`s Sensible Latent, Total' Bfuh, Btuh ,�Btuf Net Required: 0.65 90%/10% 6,995 817 7,812 Actual: 1.00 75%/25% 9,000 3,000 12,000 Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: MUZ-HM 12NA2*** MUZ-H M 12NA2*** Indoor Model: MSZ-HM12NA*** Brand: MR. SLIM MR. SLIM Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 8.5 HSPF 18 SEER Sound: 0 0 Capacity: 12,200 Btuh 12,000 Btuh Adjusted Capacity: n/a 8,660 Btuh Sensible Capacity: n/a 9,000 Btuh Adjusted Sensible Capacity: n/a 7,780 Btuh Latent Capacity: n/a 3,000 Btuh Adjusted Latent Capacity: n/a 880 Btuh AHRI Reference No.: n/a 8914075 C:\Users\donovanuser\Documents\Energy Sheets\482 Mako DA482 Mako Dr.rh9 Monday, March 19,2018, 11:50 AM DETAILED COOLING CAPACITIES# CONDENSER ENTERINGAIR TEMPERATURES°F C) EVAPORATOR AIR .. . 76[23.9 .. ..._.. _-_..__BS(29.4)__.._ .. .. .... . ..................95 35 ..1.._.. _........105 40.6........... ........1.Y6.. ......__......... ._...._._._ ._.....�.. ......... ....... ...... .... -__ -��_�: ......... ..... - ( ) _....... . _ I capacityMBtuh Total Total Capacity MBtuh Capacity MBtuh Total capacity MBtuh Total Capacity Capacity MBtuh Tota{ EWB L_, pa hY Ca ac MBtuh Total at CFM System Syatam System Syatom System S F(C) Total Sans; KW++ Total Sons$ KW Total Sons# K4W+ Total Sens# Kty.. Tata( Sens* Kw. Taut Sons# KLt rsecilon With F64CNPOISL indoor Section I 72(22.2) i 21.43 ! 1 M44 1.20 j 20,38 70.06 1.36 19.27•• 9,66 1.54 1 18.10 9.26 1.74 16.86 8.83 1.97 15.56 i 8.39 222 19.44 1 12.77 1.19 i ,4$.48-."-•'.'12139 <1i36x" 17,47 11.99 1153 16:40-)x-_.1:1^88^'a"-1:73 - 15.26 j 11.15 1.96 14.06 10,69 221 525 ) 63(17.2)11- 1 17.99 1227 1.19 ! -17.10^--•--^�1 Y':90""""'=1;95' _16.16 11,50 1.53 45x18-_-^^°•'19:OB'_"'^""^T:73 14.10 10.65 1,95 12.98 � 10.18 2.20 62(16.7) I 17.64 15.03 1.19 ! 16,78 14.64 1.35 _ 15.88 14.22 1.53 14.93 �i 13.78 1.73 14.00_ 14,00 ! 1.95 13.10 j 13.10 220 16.97 16.97 1.18 1 16.30 16.30 j 1.35_ 15.58 15,68 1.52 14_87 14,81 _ 1.73 13.917 13.98 1,95 13.08 1 13.08 2.20 72(22.2) 21.88 10.96 1.21 20,77 10.58 1 1.38 19,62 10.18 1.56 18.40 9.76 1,76 17.12 9.33 i- 1.98 15.77 8.88 223 67(19.4) 18.68 13.61 1.20 16.88 1 13.22 1 1,37 17.80 12,82 1.55 16,69 12.39 1 1,75 15.51 11.95 1197 14,27 I 11.48 222 600 83(17.2)tt T 18.40 13.06 1.20 17.47 12.87 1 1.36 16.49 12.27 1,54 _15.44 !, 1.84..__ 1.74 14,34 11,39__ 1,97 13.19 10.02 221_ 1 62(16.7) 18.08 16.13 1.20 17,20 1 15.71 1 1.36 16.27 ! 16.27 1.54 75.43 -�._-15.43 1.74 14.54- 14.54 1,97 13.59 13.59 222 57(13.9) 17.73 17.73 1.20 17.01 17.01 1.36 1624 ; 16.24 1.54 15.41 ! 15.41 1,74 14.52 I 74,52 1.97 13.57 ; 13.57 222 iF 72(22.2) 22.22 11.46 1.22 21.08 ! 11.07 1 1,39 19.88 10.66 1.57 18.63 10.24 1.77 17.31 9.60 2,00 15.92 9.35 225 67 19.4j 20.19 14.41 1 1,22 10-16-114:01 'T"^Yc38' 18.06_-_13.60 1.58 1 16:93„.,, -13.16•__._....1476...., 15.70 12.71 , 1.99 1 14.44 ! 1222 223 j675 B3 17.211 18.71 13.81 i 1.21 .1275 1==13:aT #1e38'�• 16.74 ! 12.99 1.56 .)5.06__ _ 12,55..__.._.r.1J5e� 14.53 � 1209 1.98 13.35 , 11.59 223 _ 62 l6.7) 18.48 17.11 i 7,21 17.q ! 17.83 1,38 16.80 1 16.80 1.56 15.93 15.93 1.78 14.99 14.99 1.98 13.99 13.89 2.23 j 57(13.9) 18.36 18.36 1.21 17.60 17.60 1,38 16.78 I 16.78 1.56 15.91 15.91 1.75 14.97 I 14.97 1.98 13.97 13.97 2,23 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C) { 75(23-9) 85(29.4) BS(35) 106 40.6 115(46.1 125 51.7 Ev4B Capacity MBtuh j Tow Capacity MBtuh TSI Capacity MBtuh Total Capacity MBtuh Totai Capaclry MBtuh ! Total Capacity MBtuh Total CFM 'F(*C) s# Siem System Syrtem Syetem System System Total Sen I Total Sans$ Kyy+ Total Son- KW-- Total Gena; KW+ Total Smna'# ! KW+ Tote) Sens# KW+ r Section Willi FB4CNPOJOL 700 �72 22.2 24,77 ! 13.05 1,76 1 23,65 12.62 1_86 22.49•• __12.117 2.20 2126 Section 11.73 _ 2.47 1 B.H3 _ 11.25 2.78 18.50 1 10.73_ 3.13 19.4J 22.51 18.11 1.77 21.49 15.88 1.97 20.42 15.24 2.21 19.28_ 14.78 2.48 18.08 14.29 ' 2.79 16.78 1 13.76 3.14 63(17.2)11 20.68 1 15.49 1.77 1 19,93 15.06 1.98 18.93 14.61 , 2.22 17.86 14.15 2.49 ! 16.76 13.66 2.79 15.55 ; 13.13_ 3,15 57 13.9 i 19.94 19.94 1.77 ; 1920 19.20 ! 1,98 18.43 16.43 2.22 17,60 17.617 1 2.48 16.71 1 16.71 ;2.78 ! 15.73 15.73 3.14 `gyp 72 22.2) 25.23 i 73.71 1.78 i 24,08 13.28 1,98 22.87 12.84• 2,21 2159 1238 1 2.48 2021 11,88 2.80 18.72 11.36 3.15 600 67(19.4 1 22.95 i 17.18 1.79 ! 21.86 16.74 ! 1.99 20.77 ! 16.29 222 1 19,60 1 15.82 2.49 16.35 15.31 2.80 17.01 14.77 3.18 Ail ! 21.30 1 16.48 1.79 20,31 16.04 2.00 19.27 15.59 2,23 i 18.16 j 15.11 2.50 17.02 14.61 1 2,81 15.78 14.06 3.17 1 57 13.8 20.77 20.77 1.79 19.98 19.98 2.00 1 19.16 ' 19.15 2.23 I 1827 18.27 1 2.50 17.32 17.32 1-2.81 16.27 i 1627 3.16 72(22. 25.59 1 14.34 1.80 ! 24.40 1 13.91 2.00 23.14 13.48 223 i 21.83 12.99 1 2.50 20.42 12.49 I M2 16.89 11.86 3,17 67(19.4 23.28 1 18.20 1.81 22.18 I 17.75 2.01 21.04 17.29 2.24 79.Ba 16.80 1 2.51 ! 76-58 16.28 2.82 17.18 15,70 3.18 �0 1 63 17.2)tt 1 21.63 I 17.43 1.81 ( 20.60 1 16.98 1 2.02 ) 19.63 18.51 2,25 1!7,42 18.02 ! 2.52 17.23 15.49 2.83 15.98 i 14.82 3,19 ! I I I- 57(13.9) 21.46 i 21.46 1.81 20.63 20.63 2.02 19.76 19.78 225 ! 18.82 117.62 1 2.52 1 17.82 17.82 ! 2.83 16.71 16.71 1 3.18 CONDENSER ENTERING AIR TEMPERATURES•F(°C) 1 EVAPORATOR AIR (- 75 23.9 85 290. 95(35) i 105 40.6 115 46.1 125 51.7 ' Capacity MI I Tomi Capacity MBtuh Tou11 Ca act MBtuh Total capacity MBtuh Tofal EW13 P tY po ty Capacltymetuh Total CapacityMBtuh Total CFM F C1 Syotom I Syatmm System Syetom System - System C ~ Total Sons! ! KW°• Total Sona; KW Total Sona; KW'+ 1 Total Se KW+ Total San KNN+ 7171st Sens$ KW I • 72 22.2 33.97 17.32 1.97 32.47 16.75 2.17 30.87•• 18.16 240 29.15 Section 15.54 2.87 27.30 14,87 2.98 2529 I 14.15 3.33 67 19.4 30.80 21 30 7.97 29,42 20.72 2.17 27.98 20.13 2.40 26.39 19.50 2.67 �_24.69 18.82 I 298 22.86 I 78.10 _3.32 875 63 17.211' 1 28.51 1 20.48 1.97 27.22 1 19.89 2.17 25.86 19.29 2.41 24.39 18.66 1 2.67 2282 17.96 297 21.12 17.26 3.32 fit 16. I 27.99 25.15 _ 1.97 26.74 24.55 2.17 25.44 23.90 2A1 24.07 23.17 2.87 22,67 22.67 2.97 21.30 21.30 3,32 I 57 13.9 1 27.05 27.05 1 1.97 28.06 26.06 2.18 25.01 25.01 2,41 23.88 23.88 2.67 22.64 2284 297 21.27 21.27 3.32 72(22,2 34,85 18,48 ( 2.00 33.25 17.90 2.21 31.57 17:30 2.44 28.76 18.58 2.71 27.81 15.97 3.02 26.71 i 15.24 3,37' 67 19.4 31.81 23.17 2.D1 30.15 22.59 2.21 28.60 21,97 2.44 1 26.95 21.32 1 2.71 25.16 20.61 3.02 1 23,27 i 19.84 3.36 1050 63 172 tt 2928 1 2221 I 2.01 27.91 21.62 2.21 26.47 21.00 245 1 24.84_-� -20.34 1 2.71 1 23.29 19.83 3.01 1 21.52' ! 18.88 3.36 62(16.7) 28,88 27.53 2,01 27.62 27.37 2.21 26.36 26.38 2:45 i 25.12 25.12 2.71 23.77 23.77 3.01 22.28 , 2228 3,38 J 57(13.9 26.55 28.55 2,01 27.48 27AB 2421 20.33 28.33 2.45 25.09 25.09 2.71 23,74 23,74 3.01 22.28 72 2.2 35.15 18.97 i 2.02 33.53 18.39 2.23 31.81 17.78 2.46 1 29.96 17.13 2.73 27.99 16.44 3.03 25.85 16.70 3.98 67(19,4 31,89 23.9(1 2,02 30.39 23.37 2.23 _ 28.82 22.74 2.46 27.14 22.07 2.73 25.34 21.35 3.03 23.41 j 20,56 3.38 1 1125 63(17.21'1 29.55 22.94 2.03 28.15 22.34 2.21 26.69 21.71 2.48 25,12 21.03 2.73 23.45 20.30 3.03 21.66 19.51 3.38 ' 62(16.7) 29.18 29.18 2.03 28.02 28.02 2.23 26.83 26.83 2.46 2�5.55 25.55 2.73 24.15 24.16 3.03 22.83 22.63 3,38 57(13.9) 29.10 29.10 2.03 27.98 27.98 2.23 26.80 26.80 2.46 25.52 25.52 2.73 24.13 24.13 3.03 22.60 1 22,80 3,33 ee no e9 on page r 1 n # Y t4 ! t :I MUZ-HM09NA MUZ-HM09NA2 MUZ-HM12NA MUZ-HM12NA2 MUZ-HM15NA MUZ-HM15NA2 MUZ-HM18NA MUZ-HM18NA2 MUZ-HM24NA MUZ-HM24NA2 ;i 7-1. PERFORMANCE DATA 1)COOLING CAPACITY Indoor air Outdoor intake air DB temperature(°F) t Model IWB F 75 85 95 105 115 (+ ) TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC 11 71 11.01 7.6 0.67 _ 9.7 6.6 0.79 9 0 6.2 0 83 8.3 5,7 0.86 sl MUZ-HM09NA 67 10.4 8.6 0.63 t9 7 13 4:69k` 9.0 7.4 0.75 8 4 6'.9 0.$4f 7.7 6.3 0.83 s Merz-H�na9NAa - 63 9.8 9.4 0.60 (91 78-7--7"0:86_'18.5 8.1 0.72 7 7 77'3- 0:7 7.0 6.7 0.80 71 14.7 9.4 1.08 13.7 8.7 1,18 12.9 8.2 1.27 12.0 7.6 1.34 11.0 7.0 1.39 - MUZ-HM12NA 67 13.9 10.7 1.02 13.0 10.0 1.12 12.0 9.2 1.21 11.2 8.6 1.28 10.3 7.9 1.34 MUZ-HM12NA2 63 13.1 11.8 0.97 12.1 10.9 1.07 11.3 10.2 1.16 10.3 9.3 1.23 9.4 8,5 1,28 1 71 17.2 11.1 1.04 16.0 10.4 1.14 15.1 9.7 1.23 14.0 9.1 1.29 12.9 8.3 1.35 MUZ-HM15NA 67 16.2 12.7 0,98 15.1 11.8 1.08 14.0 10.9 1.17 13.0 10.2 1.24 12.0 9.3 1.30 1' MUZ-HM15NA2 J 63 15.3 13.9 0.94 14.1 12,9 1.04 13.2 12.0 1.12 12.0 10.9 1.19 10.9 10.0 124 71 21.1 115.3 1.46 19.7 14.3 1.60 18.5 13.4 1.72 17.2 12.5 1.81 15.8 11.5 1.89 MUZ-HM18NA 67 20.0 17.2 1.38 18.6 16.0 1.52 17.2 14,8 1.64 16.0 13.8 1.74 14.7112.6 1.82 MUZ-HM18NA2 1` 63 18.7 18.6 1.31 17.4 17.3 1.45 16.2 16,1 1.57 14,7 14.6 1.67 13.4 13.3 1.74 71 27.6 20.9 2.34 25.8 19.5 2.56 24.2 18.3 2.76 22.5 17.0 2.91 20.7 15.7 3,02 MUZ-HM24NA MUZ-HM24NA2 67 26.1 23.2 2.21 24.3 21.6 2.43 22.5 20.0 2.63 20.9 18.6 2.79 19.2 17.1 2.92 63 24.5 25.1 2.10 22.7 23.3 2.33 21.2 21.6 2.51 19.2 19.7 2,68 17.6 18.0 2.79 ' NOTE: 1.IWB :Intake air wet-bulb temperature TC :Total Capacity(x103Btu/h) SHC :Sensible Heat Capacity(x103Btuth) TPC :Total Power Consumption(kW) 2.SHC is based on 80°F of indoor Intake air DB temperature. 2)COOLING CAPACITY CORRECTIONS Refrigerant piping length(one way:ft.) _ Model 25(std.) 40 65 100 MUZ-HM09NA MUZ-HM09NA2 MUZ-HM12NA 1.0 0,988 0.967 - MUZ-HM12NA2 I' MUZ-HM15NA MUZ-HM15NA2 J MUZ-HM18NA 1.0 0.985 0.963 0.933 r MUZ-HM1$NA2 MUZ-HM24NA 1.0 0.983 0.956 0.921 MUZ-HM24NA2 i Y, 2 i� - ,s OBH747D OTFICE COPY FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 84 The lower the EnergyPerformance Index, the more efficient the home. 482 Mako Dr, Atlantic Beach, FL, 32233 1. New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 550.00 ft2 b.Frame-Wood,Exterior R=19.0 456.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=19.0 104.00 ft2 4. Number of Bedrooms 1(0) d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=38.0 404.00 ft2 6. Conditioned floor area(ft2) 404 b.N/A R= ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.34 121.25 ft2 11.Ducts R ft2 SHGC: SHGC=0.26 a.Sup:Attic,Ret:System 1,AH:System 1 6 40.4 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 17.8 SEER:14.00 SHGC: b.Central Unit 12.0 SEER:18.00 d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.062 ft. a.Electric Heat Pump 17.8 HSPF:8.20b.Electric Heat Pump 12.0 HSPF:8.50 Area Weighted Average SHGC: 0.260 8. Floor Types Insulation Area 14.Hot water systems-Replacement equipment 2 a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 404.00 ft EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code complia features. Builder Signature: Date: Address of New Home: �8�tiLA�Ga �Q City/FL Zip: �` ��� z ► *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/21/2018 10:32 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 482 Mako Dr Builder Name: Street: 482 Mako Dr Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing Addition 9. Wall Types(1110.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 550.00 ft2 b.Frame-Wood,Exterior R=19.0 456.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=19.0 104.00 ft2 4. Number of Bedrooms(Bedrms In Addition) 1(0) d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (404.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 404.00 ft2 6. Conditioned floor area above grade(ft2) 404 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c• R= ft2 11.Ducts R ft2 7. Windows(121.3 sqft.) Description Area a.Sup:Attic,Ret:System 1,AH:System 1 6 40.4 a. U-Factor: Dbl,U=0.34 121.25 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 17.8 SEER:14.00 c. U-Factor: N/A ft2 b.Central Unit 12.0 SEER:18.00 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.8 HSPF:8.20 SHGC: b.Electric Heat Pump 12.0 HSPF:8.50 Area Weighted Average Overhang Depth: 3.062 ft. Area Weighted Average SHGC: 0.260 14.Hot water systems-Replacement equipment 8. Floor Types (404.0 sqft.) Insulation Area a. Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 404.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.300 Total Proposed Modified Loads: 13.92 PASS Total Baseline Loads: 16.61 hereby certify that the plans and specifications covered by Review of the plans and O '04. ST,,� this calculation are in compliance with the Florida Energy specifications covered by this , Code. calculation indicates compliance r.��" with the Florida Energy Code. rtae, , +* „ p, PREPARED BY: kC-44i F I A mak' Before construction is completed DATE: 2/21/2018- this building will be inspected for U compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. Wr OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 01 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.90 ACH50(R402.4.1.2). 2/21/2018 10:32 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: 482 Mako Dr Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 404 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 482 Mako Dr Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 32233 New/Existing: Addition Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp �/ Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 146 1168 2 Block2 258 2064 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 System 1 146 1168 No 0 1 1 Yes Yes Yes 2 System 2 258 2064 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio System 1 57 ft 0 146 ft2 ---- 0.4 0 0.6 2 Slab-On-Grade Edge Insulatio System 2 36 ft 0 258 ft2 ---- 0.4 0 0.6 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 452 ft2 102 ft2 Medium 0.96 No 0.9 No 0 26.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 404 ft2 N N 2/21/2018 10:32 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) System 1 38 Blown 146 ft2 0.11 Wood 2 Under Attic(Vented) System 2 38 Blown 258 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below im Ornt To VVall Type 1 W Exterior Concrete Block-Int InsulSystem 1 5 12.5 0 8 0 100.0 ft2 0 0 0.8 0 2 S Exterior Concrete Block-Int Insul System 1 5 31.75 0 8 0 254.0 ft2 0 0 0.8 0 3 E Exterior Concrete Block-Int Insul System 1 5 12.5 0 8 0 100.0 ft2 0 0 0.8 0 4 N Exterior Concrete Block-Int Insul System 1 5 12 0 8 0 96.0 ft2 0 0 0.8 0 5 W Exterior Frame-Wood System 2 19 22 0 8 0 176.0 ft2 0 0.19 0.8 0 6 N Exterior Frame-Wood System 2 19 13 0 8 0 104.0 ft2 0 0.19 0.8 0 7 E Exterior Frame-Wood System 2 19 22 0 8 0 176.0 ft2 0 0.19 0.8 0 8 S Garage Frame-Wood System 2 19 13 0 8 0 104.0 ft2 0 0.19 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated System 2 Metal .28 3 6.7 20.1 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.34 0.26 N 12.0 ft2 1 ft 0 in 1 ft 0 in None None 2 S 2 Vinyl Low-E Double Yes 0.34 0.26 N 30.0 ft2 1 ft 0 in 1 ft 0 in None None 3 S 2 Vinyl Low-E Double Yes 0.34 0.26 N 8.0 ft2 1 ft 0 in 1 ft 0 in None None 4 E 3 Vinyl Low-E Double Yes 0.34 0.26 N 5.3 ft2 1 ft 0 in 1 ft 0 in None None 5 N 4 Vinyl Low-E Double Yes 0.34 0.26 N 16.0 ft2 1 ft 0 in 1 ft 0 in None None 6 W 5 Vinyl Low-E Double Yes 0.34 0.26 N 30.0 ft2 6 ft 0 in 1 ft 0 in None None 7 W 5 Vinyl Low-E Double Yes 0.34 0.26 N 20.0 ft2 6 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 240 ft2 240 ft2 51 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0003 317.8 17.45 32.81 .2309 5.9 2/21/2018 10:32 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/Replacem None HSPF:8.2 17.8 kBtu/hr 1 sys#1 2 Electric Heat Pump/Suppleme Through the Wall(Split) HSPF:8.5 12 kBtu/hr 2 - Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity _ Air Flow SHR Block Ducts 1 Central Unit/Replacement for None SEER: 14 17.8 kBtu/hr 534 cfm 0.75 1 sys#1 2 Central UnittSupplemental for Through the Wall(Split) SEER:18 12 kBtu/hr 360 cfm 0.75 2 Ductless HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS --Supply---- ---Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 40.4 ft2 System 1 10.1 ft2 Default Leakage System 1 (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr Ma X Jun X Jul X Aug Se Oct Nov Dec He f X Jan f X Feb HX Mar f APr f I M yy f i Jun f l Jul f l Au4 l Sep f 1 Oct H Nov f X�Dec Ventin [ Jan [ Feb Mar [X Apr [ May [ Jun [ Jul [ Aug [ Se [X Oct X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/21/2018 10:32 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 482 Mako Dr Permit Number: Atlantic Beach,FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory).The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(%(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: . 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6. Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakagcVVindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 2/21/2018 10:33 AM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(1 WC)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 2/21/2018 10:33 AM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TMA,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916 2/21/2018 10:33 AM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5 C MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the 2. calculated total sensible load but not less than 80 percent of that load. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C): R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2/21/2018 10:33 AM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatorfte energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 2/21/2018 10:33 AM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 5 of 5 A 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 482 Mako Dr Builder Name: Street: 482 Mako Dr Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between an a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 2/21/2018 10:33 AM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 r. FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: 482 Mako Dr Builder Name: Street: 482 Mako Dr Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach, FL, 32233 Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261100 Cond.Floor Area:: 404 sq.ft. Cond.Volume: 3232 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: FORM R405-2017 : 1 Pa cfm 2 Pa cfm Tested ACH(50) 3 Per cfm *Tested leakage must be less than or equal to the 4 Pa cfm required ACH(50)shown on Form R405-2017 for 5 Pa cfm this building. If the tested ACH(50)is less than 3 the building must have a mechanical ventilation 6 Pa cfm system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either Srg performance results demonstrate compliance individuals as defined in Section ,y with Florida Energy Code requirements in 553.993(5)or(7), Florida Statutes or accordance with Section R402.4.1.2. individuals licensed as set forth in ti trrt'tf Section 489.105(3)(f) (g),or(i)or an approved third party.A written report of the results of the test shall be signed SIGNATURE: by the third party conducting the test and provided to the code official. PRINTED NAME: DATE: BUILDING OFFICIAL: DATE. 2/21/2018 10:33 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1