1629 BEACH AVE DWGS 2GENERAL NOTES AND SPECIFICATIONS D ciCN CRITERIA FLORIDA BUILDING CODE 2014 - RESDENTIAL LIVE LOADS: POOL DECK 40 PSF ALLOWABLE OWABLE UNIT STRESSES CONCRETE: (PER ACI 318) CONCRETE: - r----- SLAB ON GRADE f'c 3000 PSI STRUCTURAL POOL SHELL f'c 4000 PSI STRUCTURAL GRADE BEAMS f'c = 4000 PSI STRUCTURAL PILE CAPS Vc - 4000 PSI AUGERCAST CONCRETE ANCHOR PILE Pc = 5000 PSI REINFORCEMENT: ASTM A615 - GRADE 60 SOIL BEARING PRESSURE: 2500 PSF I AUGERCAST CONCRETE ANCHOR PILES 1) MINIMUM 14" DIAMETER 2 MINIMUM 18'-0" LENGTH 3 REINFORCE w/ 6-#5 w/ #3 TIES AT 12"O -C 4 CONCRETE fc = 4000 PSI 5) PILE CAPACITY SHALL BE 20 TONS. REINFORCED CONCRETE ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITH N OF ACI 318 AND ACI 301. CONCRETE MIX DESIGNS SHALL BE SUBMITTED FOR THE REVI W AND APPROVAL OF THE STRUCTURAL ENGINEER. UNLESS OTHERWISE SHOWN ON DRAWINGS, MINIMUM COVER FOR REINFORCING SHALL BE AS FOLLOWS: SLABS ON GRADE CENTERED STRUCTURAL POOL SHELL 2" STRUCTURAL SPA SHELL 2" GRADE BEAMS AND PILES 3" CONCRETE MAXIMUM WATER CEMENT RATIO: STRUCTURAL POOL SHELL SLABS AND WALLS 0.42 CONCRETE PILE CAPS AND GRADE BEAMS 0.42 AUGERCAST ANCHOR PILE 0.46 REINFORCMENT: ASTM A615 - GRADE 60 WELDED WIRE FABRIC ASTM A185 SOIL BEARING PRESSURE: 2D00 PSF REINFORCED CONCRETE ALL REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60. ALL WELDED WIRE FABRIC SHALL CONFORM TD ASTM A185. ALL HOOKS IN REINFORCING BARS SHALL BE ACI STANDARD HOOKS, ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED AND SPACED IN FORMS AND SECURED IN PLACE IN ACCORDANCE WITH THE PROCEDURES AND REQUIREMENTS OUTLINED IN THE LATEST EDITION OF THE 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES', ACI 315. BAR SUPPORT` SHALL BE PLASTIC DIPPED AFTER FABRICATION. ALL REINFORCING SPLICES SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITII)N OF ACI 318, BUT IN NO CASE SHALL BE LESS THAN 40 BAR DIAMETERS, U.O.N. ALL WELDED WIRE FABRIC SHALL BE LAPPED TWO (2) MESH PANELS AND TIED SECURELY. WHERE REQUIRED, DOWELS SHALL MATCH SIZE AND NUMBER OF MAIN REINFORCING, U.O.N. SUPPLEMENTARY NOTES VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS AND POOL DRAWINGS ELECTRICAL, AND POOL DRAWINGS. THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, SEQUENCES, ACTS AND/OR OMISSIONS OF THE CONTRACTOR, OR ANY OTHER PERSONS PERFORMING WORK, NOR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT WORK IN ACCORDANCE WITH THESE CONTRACT DOCUMENTS. PROVIDE ALL TEMPORARY BRACING, SHORING, GUYING, OR OTHER MEANS TO AVOID EXCESSIVE STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. IF THE FOOTING ELEVATIONS SHOWN OCCUR IN A DISTURBED, OR UNSTABLE SOIL, THE ENGINEER SHALL BE NOTIFIED. TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS ESTABLISHED IN SECTION 626-33.007, FLORIDA ADMINISTRATIVE CODE. THE POOL HAS BEEN DESIGNED NOT TO INCREASE THE RISK OF DAMAGE OF ADJACENT DWELLINGS DURING A COASTAL STORM EVENT AS REQUIRED BY FAC 628-33.007(5)(m)(n). 10'-5%" . iv -3„ � II 1' PAVER AND POOL BACKFILL NOTES I. THE CONTRACTOR SHALL BACKFILL THE POOL WITH CAUTION, THE PLUMBING SHALL BE SECURED AND PROTECTED DURING BACKFILL AND SHALL NOT BE DISTURBED. BACKFILL SHALL BE CLEAN SAND, FREE OF ROCKS AND DEBRIS PRODUCED DURING EXCAVATION OF THE POOL AND ANY ORGANIC MATERIAL, MUCK OR MARL. BACKFILL SHALL BE PLACED IN LIFTS NOT TO EXCEED 12'AND COMPACTED TO 90% OF THE MATERIALS MAXIMUM DENSITY. II. WATER WANDING OR 'JUKING'DOES NOT CONSTITUTE PROPER BACKFILLING / COMPACTING AND SHALL NOT BE CONSIDERED AN ACCEPTED METHOD, NO EXCEPTIONS. III. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A GEOTECHNICAL REPORT TO THE OWNER AND LANDSCAPE ARCHITECT / ENGINEER AS PART OF THEIR BID PRIOR TO IMPLEMENTATION, INCLUDING AT A MINIMUM: (1) AUGER BORING 3 -MINIMUM BELOW THE DEEPEST PORTION OF THE POOL. (2) SOIL PRESSURE TEST. GEOTECHNICAL ENGINEERS SUMMARY OF THE SOIL CONDITIONS FOR IMPLEMENTATION OF A SWIMMING POOL. IV. THIS POOL IS BASED ON SOIL CONDITIONS CONSISTING OF WELL COMPACTED STRUCTURAL FILL, IF OTHER CONDITIONS ARE ENCOUNTERED, SUCH AS MUCK, NON—ANGULAR SAND, ORGANICS, MARL, ETC ... THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE OWNER OR ENGINEER. DEP RELATED DESIGN CRJTERIA DEP MONUMENT NUMBER = R-46 DUVAL COUNTY 100 YR. STORM ELEVATION - +16.3 NAVD (FROM MONUMENT) 100 YR, STORM DESIGN GRADE ELEVATION - +4.4 NAVD (FROM MONUMENT) BOTTOM OF PILING - -5.0 NAVD BOTTOM OF LOWEST HORIZONTAL POOL BEAM = +12.8 NAVE) TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THESE POOL DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS ESTABLISHED IN SECTION 628-33.007, FLORIDA ADMINISTRATIVE CODE. THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS AND GUIDELINES ESTABLISHED IN CHAPTER 12.9.4 AND CHAPTER 13.5.3 OF FEMA 55, COASTAL CONSTRUCTION MANUAL AND APPENDIX L TO THE FEMA 55, COASTAL CONSTUCTION MANUAL. THE POOL HAS BEEN DESIGNED NOT TO INCREASE THE RISK OF DAMAGE OF ADJACENT DWELLINGS DURING A COASTAL STORM EVENT AS REQUIRED BY FAC 62B-33.007(5)(m)(n) AND FEMA 55, CHAPTER 12.9.4. THESWIMMING POOL HAS BEEN DESIGNED AS AN EXPENDABLE STRUCTURE FOUNDATION LEGEND I 14" DIAMETER CONCRETE ANCHOR PILE. - — - INDICATES GRADE BEAM, SEE DETAIL 1 & 2/PS-2 FOR REINFORCEMENT ,{ 1 INDICATES DETAIL NUMBER n-1-1 INDICATES BUILDING AND SHEET NUMBER T.O.S. TOP OF SLAB ELEVATION NOTES. 1) PRESSURE PIPING SHALL BE TESTED AS PER LOCAL BUILDING CODES, PRIOR TO BACKFILL. 2) ALL DEP APPROVED SAND FILL SHALL BE BACKFILLED AND TO A DENSITY COMPACTED Of 95% OF D"MIUM MODIFIED STANDARD ASTN PROCTOR TEST, BACKFILL SHALL BE IN 12" LAYERS. 3) THE OWNER SHALL INSTALL AND MAINTAIN A FOUR (4) FOOT HIGH (MINIMUM) FENCE AROUND THE POOL AREA (TO MEET OR EXCEED LOCAL CODES). 4) REFER TO POOL MANUFACTURERS PLANS FOR DETAILS OF THE POOL, PUMBING/PIPING, AND ELECTRICAL REQUIREMENTS. 2 POOL SECTION PS -1 \HUULLUGL. SLG DETAIL 1/PS-2 SIM. POOL / SPA SHELL PIAN SCALE -1%4- - 1�0 �--- ---... .-- - — - - - - - - - - - p------------- BxB SPA ( INFINITY ) (BEYOND) EDGE ------------------ i I I 1 I I I I I 1 POOL STEPS 1 I I 2"x3" CONIC. , I I I I 8" POOL Ili POOL BUMPOUTS I 1 1 SHELL 10" W COLLECTION I 1 I •1' -------- ___�` I <. TROUGH I I I 1 I I I ' • 1 TYP. STAIR SEE j 1 I . • ,,, - ."' DETAIL 3/PS-2 SIM. I ., �•—------------- � 1 GRADE BEAM SEE I ! •'I' '1" ' DETAIL 2/PS-2 SIM, I I 1 I 1 I I I J I I I I GRADE BEAM, SEE ( ) DETAIL 2/PS-2 SIM. ------------------ — — — — — ——-. LONGITUDINAL POOL SECTION NOTE SEE DETAILS FOR REINFORCING NOT SHOWN HERE FOR CLARITY SEE DETAIL 4/PS-2 I SPA ATER LINE rPOOLIWATER ,r I LINE r — �`-- SPA I SPA BENC% I I � r'"c I I 1 I I 1 I I` I I ` 1 I I I I 1 I I I I I I II I 3 SPA SECTION PS -1 SEE DETAIL 5/PS-2 �g V / 1 Lou PonnSo and Associates. Inc. 420 Osceola Avenue lax. Beach. Florida 32250 Ph.242-0908 Fax.241.9557 FF,QL: CpAAk, 8344 5C CA"M�3�579 COMM �•x�CUM REVLSIO.6 DAIS Pill ALTERATION "Ell I g.T111 LT IN O O (I. Lu Vj U Z LL w�U O < W �QUU m Q W�CO Z QT�V zzQ O ICL POOL SHELL DESIGN NOTES, PLAN AND SECTIONS PLAN NAMF PFOTENHAUER RE810ENCF PODL DESIGN/DRA WN/CH EC KED CN KJL LAP DATE 07-14-15 CONTROL NO. TRUSS ID. LPA NO. PFOT-15-00006 SHEET PS -1 SHEET i OF 2 - r----- , r- -----��- ^-%STEPS I I I I I N I I I I 3' 3" . I I 1 I I POOL I I I o SPA 3 N ,� I I B THICK CONCRETE I SLAB w/{j5 ®8"D.t I DRAT 11 , SEE PS -2 1 I STEPS I I EACH IWAV BOTTOM I I I _ 1' PAVER AND POOL BACKFILL NOTES I. THE CONTRACTOR SHALL BACKFILL THE POOL WITH CAUTION, THE PLUMBING SHALL BE SECURED AND PROTECTED DURING BACKFILL AND SHALL NOT BE DISTURBED. BACKFILL SHALL BE CLEAN SAND, FREE OF ROCKS AND DEBRIS PRODUCED DURING EXCAVATION OF THE POOL AND ANY ORGANIC MATERIAL, MUCK OR MARL. BACKFILL SHALL BE PLACED IN LIFTS NOT TO EXCEED 12'AND COMPACTED TO 90% OF THE MATERIALS MAXIMUM DENSITY. II. WATER WANDING OR 'JUKING'DOES NOT CONSTITUTE PROPER BACKFILLING / COMPACTING AND SHALL NOT BE CONSIDERED AN ACCEPTED METHOD, NO EXCEPTIONS. III. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A GEOTECHNICAL REPORT TO THE OWNER AND LANDSCAPE ARCHITECT / ENGINEER AS PART OF THEIR BID PRIOR TO IMPLEMENTATION, INCLUDING AT A MINIMUM: (1) AUGER BORING 3 -MINIMUM BELOW THE DEEPEST PORTION OF THE POOL. (2) SOIL PRESSURE TEST. GEOTECHNICAL ENGINEERS SUMMARY OF THE SOIL CONDITIONS FOR IMPLEMENTATION OF A SWIMMING POOL. IV. THIS POOL IS BASED ON SOIL CONDITIONS CONSISTING OF WELL COMPACTED STRUCTURAL FILL, IF OTHER CONDITIONS ARE ENCOUNTERED, SUCH AS MUCK, NON—ANGULAR SAND, ORGANICS, MARL, ETC ... THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE OWNER OR ENGINEER. DEP RELATED DESIGN CRJTERIA DEP MONUMENT NUMBER = R-46 DUVAL COUNTY 100 YR. STORM ELEVATION - +16.3 NAVD (FROM MONUMENT) 100 YR, STORM DESIGN GRADE ELEVATION - +4.4 NAVD (FROM MONUMENT) BOTTOM OF PILING - -5.0 NAVD BOTTOM OF LOWEST HORIZONTAL POOL BEAM = +12.8 NAVE) TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THESE POOL DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS ESTABLISHED IN SECTION 628-33.007, FLORIDA ADMINISTRATIVE CODE. THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS AND GUIDELINES ESTABLISHED IN CHAPTER 12.9.4 AND CHAPTER 13.5.3 OF FEMA 55, COASTAL CONSTRUCTION MANUAL AND APPENDIX L TO THE FEMA 55, COASTAL CONSTUCTION MANUAL. THE POOL HAS BEEN DESIGNED NOT TO INCREASE THE RISK OF DAMAGE OF ADJACENT DWELLINGS DURING A COASTAL STORM EVENT AS REQUIRED BY FAC 62B-33.007(5)(m)(n) AND FEMA 55, CHAPTER 12.9.4. THESWIMMING POOL HAS BEEN DESIGNED AS AN EXPENDABLE STRUCTURE FOUNDATION LEGEND I 14" DIAMETER CONCRETE ANCHOR PILE. - — - INDICATES GRADE BEAM, SEE DETAIL 1 & 2/PS-2 FOR REINFORCEMENT ,{ 1 INDICATES DETAIL NUMBER n-1-1 INDICATES BUILDING AND SHEET NUMBER T.O.S. TOP OF SLAB ELEVATION NOTES. 1) PRESSURE PIPING SHALL BE TESTED AS PER LOCAL BUILDING CODES, PRIOR TO BACKFILL. 2) ALL DEP APPROVED SAND FILL SHALL BE BACKFILLED AND TO A DENSITY COMPACTED Of 95% OF D"MIUM MODIFIED STANDARD ASTN PROCTOR TEST, BACKFILL SHALL BE IN 12" LAYERS. 3) THE OWNER SHALL INSTALL AND MAINTAIN A FOUR (4) FOOT HIGH (MINIMUM) FENCE AROUND THE POOL AREA (TO MEET OR EXCEED LOCAL CODES). 4) REFER TO POOL MANUFACTURERS PLANS FOR DETAILS OF THE POOL, PUMBING/PIPING, AND ELECTRICAL REQUIREMENTS. 2 POOL SECTION PS -1 \HUULLUGL. SLG DETAIL 1/PS-2 SIM. POOL / SPA SHELL PIAN SCALE -1%4- - 1�0 �--- ---... .-- - — - - - - - - - - - p------------- BxB SPA ( INFINITY ) (BEYOND) EDGE ------------------ i I I 1 I I I I I 1 POOL STEPS 1 I I 2"x3" CONIC. , I I I I 8" POOL Ili POOL BUMPOUTS I 1 1 SHELL 10" W COLLECTION I 1 I •1' -------- ___�` I <. TROUGH I I I 1 I I I ' • 1 TYP. STAIR SEE j 1 I . • ,,, - ."' DETAIL 3/PS-2 SIM. I ., �•—------------- � 1 GRADE BEAM SEE I ! •'I' '1" ' DETAIL 2/PS-2 SIM, I I 1 I 1 I I I J I I I I GRADE BEAM, SEE ( ) DETAIL 2/PS-2 SIM. ------------------ — — — — — ——-. LONGITUDINAL POOL SECTION NOTE SEE DETAILS FOR REINFORCING NOT SHOWN HERE FOR CLARITY SEE DETAIL 4/PS-2 I SPA ATER LINE rPOOLIWATER ,r I LINE r — �`-- SPA I SPA BENC% I I � r'"c I I 1 I I 1 I I` I I ` 1 I I I I 1 I I I I I I II I 3 SPA SECTION PS -1 SEE DETAIL 5/PS-2 �g V / 1 Lou PonnSo and Associates. Inc. 420 Osceola Avenue lax. Beach. Florida 32250 Ph.242-0908 Fax.241.9557 FF,QL: CpAAk, 8344 5C CA"M�3�579 COMM �•x�CUM REVLSIO.6 DAIS Pill ALTERATION "Ell I g.T111 LT IN O O (I. Lu Vj U Z LL w�U O < W �QUU m Q W�CO Z QT�V zzQ O ICL POOL SHELL DESIGN NOTES, PLAN AND SECTIONS PLAN NAMF PFOTENHAUER RE810ENCF PODL DESIGN/DRA WN/CH EC KED CN KJL LAP DATE 07-14-15 CONTROL NO. TRUSS ID. LPA NO. PFOT-15-00006 SHEET PS -1 SHEET i OF 2 T POOL WALL EL. + NAVD X14 VERTICAL 0 B"o.c, / CENTERED, ALIGNED w/ SLAB REINFORCING #4 HORIZONTAL 0 12"o.c, CENTERED 'a 5-#5 TOP AND 5 -NS BOTTOM w/ #3 STIRRUPS 0 12"o.c GRADE BEAM REINFORCING 1 2'- 1 TYPICAL POOL EDC S-2 SCALE: 3/4" _ T�POOOL WALLO -EL. +21.25 NA11 FINISH, SEE ARCH J #4 VERTICAL 0 B"o.c,-,. CENTERED, ALIGNED W/ 3 SLAB REINFORCING S Pool - p5 0 B"o.c TOP m "I q5 0 wo.c EA. WAY BOT. ea 14"0 AUGERCAST CONC ANCHOR PILE / (TYPICAL 11 LOC.)-/ 4 SPA TO POO PS -2 SCALE: 3/4" - 1'—D" �-FINISH, SEE ARCH 14 VERTICAL )#'4 CONT. IN TOP EDGE 0 8" O.C. 12" WALLS #5 0 B" O.C. TOP 8" STRUCTURAL CONCRETE /5 0 B" O.C. TOP Q Bum OUTS POOL SHELL WALL #3 HORIZONTAL B" STRUCTURAL ELASTOMERIC SEALANT 0 8" 0 C {j5 0 8"o.c FOP CONCRETE SLAB 8" STRUCTURAL NTERED, ALIGNED w/ COLLECTION MANUFACTURER/OWNER PER POOL CONTRACTOR SLAB REINFORCING CONCRETE SLAB 4 TROUGH SLOPE 1/3 SPAN TO R FORCING 1/3 SPAN TOP REINFORC G z s 2-#4 p4 HOOKED DOWELS p, -8" STRUCTURAL SUPPORT TILE COMPACTED SAND BED DESIGNED BY POOL CONTRACTOR w/ p3 STIRRUPS 0 12"o.c S 1/3 SPAN TOP REINFORCING CONCRETE SLAB GRADE BEAM REINFORCING VERTICAL 0 8" O.C. 2-jj4 SUPPORT N ° 0 12" D.C., CONTINUOUS AROUND2-�J4 —� CENTERED PEREMETER (TYPICAL) N3 HORIZONTAL 0 8" O.C. 2-Q4 SUPPORT #4 VERTICAL 0 S" O.C., 14"0 AUGERCAST / _I 6"I_ CENTERED n 3" CLR'I .. .� ao 3 �YCLR EA. WAY BOT. I_ �'-. 0 B" O,C. p'5 EA. WAY BOT EA. WAY BOT. 5-/5 TDP AND S -M5 LOWEST POOL BEAM BOTTOM w/ #3 STIRRUPS EL. +12.83' NAVD 0 12" O.C. GRADE BEAM BEND OVER VERTICAL /5 REINFORCING INTAUGO GRADE BRCAST EAM/SLAB RLE EINFORCING 24"w x 20"d STRUCTURAL GRADE BEAM AT MIDDLE 14"0 AUGERCAST CONCRETE '-2" ANCHOR PILE (TYPI"AL ,., 11 LOCATIONS) DETAIL (4)1(14 CONT, IN TDP OF 12" WALLS 16" SPA BENCH SPA EDGE DETAIL TRAVERTINE STONE OVER COMPACTED SAND BED. FINISH TO BE DETERMINED BY POOL CONTRACTOR BUILD UP PERIMETER OF DECK WITH EXCAVATED EXISTING SAND FILL SLOPE EXISTING GRADE 5-W5 TOP AND BOTTOM w/ p3 0 12"o.c GRADE REINFORCING STABILIZED SUBGRADE, NON -PLASTIC, INORGANIC, EXISTING EXCAVATED GRAN SOIL COMPACTED TO A DENSITY OF AT LEAST 95% OF THE PROCTOR MAXIMUM DRY DENSITY (ASTM D 1537) POOL DECK TRAVERTINE STONE SCALE: 3/4" = V -D" PS T POOL WALL EL. +20.7 NAVD T- 01 SEE DETAIL 2/P-1 FOR REINF. (TYP) r_f1 TYPICAL POOL EDGE DETAIL33 TYPICAL STAIR DETAIL' 1 ps-2 SCALE: 3/4" - i'-0" <\ PS -2 SCALE: 3/4 - 1-0 5 SPA EDGE DETAIL ps- SCALE: 3/4" = 1'—D" 6- LAYER SAND BASE CO PACTED TO A DENSITY OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM CRY DENSITY (ASTM D 1537) DESIGNED BY POOL MAINTAIN 2" CONCRETE COVER AROUND OPENING DEEP WELL DRAIN CONC ANCHOR PILE (TYPICAL 11 LOC.) K-6-'\ SPILLWAY EDGE DETAIL p$-2 SCALE: 3/4" = 1'—D" ADD 4pce #'4 x 3'-D" DIAGONALS AROUND DEEP WELL DRAIN OPENING ,y5 0 12" O.C. EACH WAY POOL SLAB REINFORCING DEEP WELL DRAIN OPENING (7� REINFORCING DETAIL ps-2 SCALE: 3/4" = 1'—D" 12" OF DRAINAGE FILL (3/4" CRUSHED ROCK OR STONE)— MIRAGRID 3XT GEOSYNTHETIC MIRAGRID 3XT GEOSYNTHETIC MIRAGRID 3XT GEOSYNTHETIC MIRAGRID 3XT GEDSYNTHETIC MIRAGRID 3XT GEDSYNTHETIC FDUNDA170N SOIL j/ 71 TYPICAL COPING/EDGE DETAIL P$-2 SCALE: 3/4" V -D" M RAILING (AS REQUIRED BYi i _EXTEND BARS TO WITHIN LOCAL CODE) 3" OF TOP OF SLAB (TYP) KEYSTONE I CAP T PILE VARIES T/SLAB SEE PLAN L. +3385NAV PILE SECTION h" 14"M AUGER CAST PILE 16" w/ 6-#5 x 18'-D" LONG w/ g3 TIES 0 12" oc 10_ STACKED STONE WALL DETAIL ps-2 SCALE: 3/4" = 1'-0" FIBERGLASS PIN PER KEYSTONE UNREINFORCED CONCRETE LEVELING PAD 0 In BOT PILE -5.00 NAVb TYPICAL PILE n_ ELEVATION PS -2 SCALE: 1/4" . V -D" fi As saciate s, Inc. 420 Osceola Avenue I ax. Beach Florida 32250 Ph.242-0908 Fax.241-9557 FL: CA k 83r44�S�C: CSA# 3.579 SON f�}I 1 ,rxR) p tl•hyCOM r REVISIONS DATE PHO ALTERATM J ^O (1. W U Q u - Lu W U < UJI �Urrl U W LL!in Z CpJV ' Z �p Q L`LJ 1 O //L�L I..L POOL AND SPA DETAILS PLAN NAMF PFoTEKIWJER REsmcE POOL DESIGN/DRA WN/LH ECKED CS KJL LAP DATE 07-14-15 CONTROL NO. TRUSS ID, LPA NO. PFOT-15-0= SHEET PS -2 H 2 INFINITY —Z 14 VERTICAL )#'4 CONT. IN TOP EDGE 0 8" O.C. 12" WALLS 2"x3" CONC. Bum OUTS '/z" EXPANSION JOINT w/ #3 HORIZONTAL ELASTOMERIC SEALANT 0 8" 0 C CANTILEVERED CONCRETE TRAVERTINE STONE OVER 14 VERTICAL 0 8"o.c, COPING AS PER POOL PI ED AND B AS NTERED, ALIGNED w/ COLLECTION MANUFACTURER/OWNER PER POOL CONTRACTOR SLAB REINFORCING 4 TROUGH SLOPE WATER LINE p4 HOOKED DOWELS 6°' WATERLINE-� 5-1y5 TOP AND 5-5 BOTTOM VERTICAL 0 B" ON -CENTER IN B' WALL TILE COMPACTED SAND BED DESIGNED BY POOL CONTRACTOR w/ p3 STIRRUPS 0 12"o.c W a HOOKED DOWELS GRADE BEAM REINFORCING VERTICAL 0 8" O.C. #4 HORIZONTAL 10" BOND BEAM w ° 0 12" D.C., CONTINUOUS AROUND2-�J4 ' CENTERED PEREMETER (TYPICAL) N3 HORIZONTAL 0 8" O.C. #4 VERTICAL 0 S" O.C., 14"0 AUGERCAST / _I 6"I_ CENTERED CONC ANCHOR PILE (TYPICAL 11 LOC.) K-6-'\ SPILLWAY EDGE DETAIL p$-2 SCALE: 3/4" = 1'—D" ADD 4pce #'4 x 3'-D" DIAGONALS AROUND DEEP WELL DRAIN OPENING ,y5 0 12" O.C. EACH WAY POOL SLAB REINFORCING DEEP WELL DRAIN OPENING (7� REINFORCING DETAIL ps-2 SCALE: 3/4" = 1'—D" 12" OF DRAINAGE FILL (3/4" CRUSHED ROCK OR STONE)— MIRAGRID 3XT GEOSYNTHETIC MIRAGRID 3XT GEOSYNTHETIC MIRAGRID 3XT GEOSYNTHETIC MIRAGRID 3XT GEDSYNTHETIC MIRAGRID 3XT GEDSYNTHETIC FDUNDA170N SOIL j/ 71 TYPICAL COPING/EDGE DETAIL P$-2 SCALE: 3/4" V -D" M RAILING (AS REQUIRED BYi i _EXTEND BARS TO WITHIN LOCAL CODE) 3" OF TOP OF SLAB (TYP) KEYSTONE I CAP T PILE VARIES T/SLAB SEE PLAN L. +3385NAV PILE SECTION h" 14"M AUGER CAST PILE 16" w/ 6-#5 x 18'-D" LONG w/ g3 TIES 0 12" oc 10_ STACKED STONE WALL DETAIL ps-2 SCALE: 3/4" = 1'-0" FIBERGLASS PIN PER KEYSTONE UNREINFORCED CONCRETE LEVELING PAD 0 In BOT PILE -5.00 NAVb TYPICAL PILE n_ ELEVATION PS -2 SCALE: 1/4" . V -D" fi As saciate s, Inc. 420 Osceola Avenue I ax. Beach Florida 32250 Ph.242-0908 Fax.241-9557 FL: CA k 83r44�S�C: CSA# 3.579 SON f�}I 1 ,rxR) p tl•hyCOM r REVISIONS DATE PHO ALTERATM J ^O (1. W U Q u - Lu W U < UJI �Urrl U W LL!in Z CpJV ' Z �p Q L`LJ 1 O //L�L I..L POOL AND SPA DETAILS PLAN NAMF PFoTEKIWJER REsmcE POOL DESIGN/DRA WN/LH ECKED CS KJL LAP DATE 07-14-15 CONTROL NO. TRUSS ID, LPA NO. PFOT-15-0= SHEET PS -2 H 2 ADJACENT 3 HOMES GENERAL FURTHESTI `—PERMIT !—VERTICAL FLOOD � FLOOD i LINE I EROSION ZONE I ZONE CONSTRUCTION x I Ao f- CONTROL 'AO' 'VE' 1 LINE I LINE I I_ i ----------------�---- ------------- --- I I DIMEN51ON5 5HOWN ARE i TO EDGE OF WATER COASTAL �—CONTROL TWO STORY FRAME I I % CONSTRUCTION RESIDENCE RboFEp I WboD I I LOT l C VER PATIO I I % POOL EQUI?MENT I=E I APPROXIMATE NEW MASONRY STEPS I I EDGE OF VEGETATION NEW MASONRY 5 BEEN WALL—\\_g SET PA �UALKWAY SEGMENTAL WALL EDGE I\ t NNW PAVER 91DENCE G URTYARD '1629 21 04 .24 6t $ aye - I�61DlNC! t gto $.i9 x9.3 IFFE-2126' 00 I N TWO STORY FRAME RESIDENCE #1631 FFE-2128' xl I �rn L- I Vit\ 1 D IVE-Y 1 I SAND SET PAVER WALKWAY -/NE I I / I I COASTAL CONTROL CONSTRUCTION LE � 1 I I I I I L3 R xt5 p TE P LM, TYP ,0.9 5 5 7.B x42 .Ixt4� x11. 1 x126 I • `_ �� . r % i tt y i i 1 FILL/AREEA / \ ' i'i 11 ��G�P N TRAVERT E P OL (DECK `--- I I I I I i I x .3 x.2 C'- ,2.s x 3.2', . xt2, l li xe.7 xe.e \ I \ 1 x5.o 1 I II ( II CIV `�. 1 1 ENEW L DE�KTINE 1 cI�c Fu,, AREA, \) q� \ I ^� I I I �'� I ri�P� I I I I \ PATE PA& I, TYP. xo.3 ^ g----=�--- � W MASON PY SCREEN WALL SAND SET PAVER WALKWAY 6" !m SEASONAL MEAN x�2 �'ze7 x6.7 01°° 1 ° I HIGH WATER HIGH WATER I SEGMENTAL WALL EDGE $ LINE - ELEv. 9B5' LINE - ELEV. 22' °I ° I ° ONE STORY FRAME I i ml m I m REE IDENCE o 5 619 1 i -1 m m ol0 1 EROSION z l i f- CONTROL , PAVER LINE r�y�n I rn . I PATIO i ---------------- I I I GENERA ADJAGENT3 HOMES I Imo—PERMIT FURTHEST I LINE �— VERTICAL i CONSTRUCTION x I AO 1 LINE I I SITE i=LAN - 1(o29 5EAC>4 A x -1.1x.1.8 SITE DATA - IMPERVIOUS / PERVIOUS CALCULATIONS SITE AREA: 13,476 SQ. FT. MAXIMUM IMPERVIOUS AREA: 50% (6, 738 SQ. FT.) HARDSCAPE TAKE -OFFS: IMPERVIOUS MAIN HOUSE COVERAGE 1,492 SQ. FT. APARTMENT/GARAGE 934 SQ. FT. COURTYARD PATIO 904 SQ. FT. AC / POOL EQUIPMENT PADS: 131 SQ. FT. WALKWAYS & STEPS 649 SQ. FT. POOL & SPA DECK 1,294 SQ. FT. DRIVEWAY 345 SQ. FT. TOTAL: 5,749 SQ. FT. I PERCENTAGE OF SITE IMPERVIOUS: 42.7% 3002 Phllllp5 Hlca vay Jack5orndle, FL 32207 (904)858-4300 WWW,crow Ipod51t1L,corn CJ 8ER Mil PVOJ�CT INFCVMA11ON XAWING 111L�: 51TE PIAN 5c&L : 1/32"-I' PASS 3,10,17 t9MWN 13Y: YA EXISTING DEVELOPMENT IMPERVIOUS SURFACE ECOT DEVELOPMENT IMPERVIOUS SURFACE TREES / PALMS REMOVED GDNTINUOU91'A Ic FENCE LOT SIZE - 13,416 OF 100% LOT SIZE - 13,4'16 OF 100% (2) 3' DRAKE ELMS - 6' HOUSE FOOTPRINT - APARTMENT FOOTPRINT 1,492 OF 934 OF H USE FOOTPRINT - ARTMENT FOOTPRINT 1,492 OF - 934 OF (2) 10' WASHINGTONIA PALMS - 12' CT 2 WOOD 2 2 x x W 4' oC. - BRICK PATIO - 349 OF S ONE PATIO - 904 5F (3) 12' CABBAGE PALMS - 16' CT' WALKWAYS - 387 51= W LKWAYS - 381 OF BURY FABRIC 3' DEEP STEPS - 282 OF OL PECK - 1294 SF , S STAKE DRIVEWAY - 345 5F LL EQUIPMENT PAD 49 OF ZONING CLASSIFICATION - RS -2 A/C PADS - 82 OF S EPS - 262 OF LOT WIDTH - 50' DRIvE STAKE 6" INTO GRND. _ EUTHENICS DRIVEWAY - 345 SF STUDIO TOTAL IMPERVIOUS 3,941 OF 29.2% C PADS - 82 5F _ TOTAL PERVIOUS 9,535 OF 10.8% TOTAL IMPERVIOUS 5,161 OF 42.1% LAND ARCHITECTURE TOTAL PERVIOUS 1,115 OF 51.3% - SILT FENCE DETAIL URBAN PESIGGNN NQ FLOOD ZONE—� I GENERAL 'r W4 333 1403 SILT FENCE I LINE f"+—PEIR IT AO � vE KmIhww4o Gm•tnw1 LOCATION X' I 'AO' I 6EOR61A RE& NO. i69 EROSION I CONTROL LINE /I GOA5TA I CON I I % LINESTSTR GTION TWO EXISTING I STORY FRAME RESIDENCERpOOD p I I I PEAL 1633 d�7j / LOT 1 DIEL / I PATIO I I �I ON STORY FRAME PERIMETER GARAGE SILT FENCE I I I I I w TO LIVE OINK / REMOVE: REMOvE PERIMETER I I CONCRETE STEPS WOOD DECK __ SILT FENCE U x 6.06I'ZI� 7 BRICK WALLS REMOVE PALM 71.5 3 �� ( \ x 15 I 5U•U'9 1 ,I I x 51 w w / A/C PAD T �i I / / / 1.1 1 / \\ II II II I� ' I W PA,BLH TOONIA jI I REMAIN 17 1 1 I I RE816 -J / I I I 1 o 2 U I b! FL GARAGE EXISTING I J / I I / L------ / I \ j I I LL 2nd RESIDENCE TWO STORY FRAME RESIDENCE ie.2 <� 1 j 1 1 11 I x166 ni W Q wI In I FFE-2126' 1631 6�' ? 1 1 x12. / I / x9.7 I x9.5 16 I \\ x5.5 \\ I I� z Lu Q Fr -E-2128' !I I II x6N i S W DUMPSTER WASHINGTONIA LOT 6 I' I I 100 z W M LOCATION _ PALM TO RsMAIN ILu \\\ I \\ ( I it 1/ I I i (\ I I W 6\ F CHEMICAL I cp i N r \ Z TOILE T LOCATI 1 CONCRETE ! I ,\'I 114 ) ) \ I w Q xB.04 _ 1 11 9 _� �,j I x6.2 6.00 x 1 I x .— I REMOVE )VE PALMS GAP / COVER REMOVE. WELL REMOvE PALM I I WOODEN STEPS iFILLIETYARD WOODEN DECK BRICK SEAT WALLS REMOVE GAS TANK) I S L1T PETNCE .6 I x6.7 CIO PERIMETER SILT FENCE SPACE TO GRADE TIOTRZ I x6 7 / CON W/ EROSION TRUGt RAMP CONTROL TAGGED TAGGED PALMS I I N OO LL WOODEN STEPS BLOCK WALLS EXISTING I m CONCRETE WALKS ONE STORY FRAME mI I I I IN THIS AREA RESIDENCE I � / Ij 1619 I LOT 5 >4 p1 r*I / COASTAL I I I p r SHEET TITLE / CONTROL CONSTRUCT ON�I� I I = ID LINE rO�o I EROSION O DEMOLITION o I PAVER I I� CONTROL LINE Z PLAN �I PATIO j I ? — — — — i— — — — — — — — — — — — — — — — — — —xrt-- i� I AO VIE DATE ISSUED �rj IGENERAL L.. GENERAL APRIL D. 20 16 PERMITLINE a o��ia��6 I SITE DEMOLITION PLAN 1631 BEACH AVENUE I X I AO i SCALE 12 I74.. x �,. x .%6 I I�RTH SHEET L 2 OF 12 Q0000,e EUTHENICS STUDIO TWO STORY FRAME LAND ARCHITECTURE COMMUNITY PLANNING URBAN DESIGN 1633 904 333 1483 Ic�l ImarNeomce�tnst FLORIDA REG. NO. 1160 (� GEOWAIA REG. NO. 666 CONSTRUCT WALL IN B' PANELS FOR FRANGIBILITY 1388FNNEW CMU WALL ---- \ PROPOSED xt5.5 2" STAINLESS \� STEEL POST C4' O.G.) _ \x18.3 DATE PALM \ AND4 5' - 8" w \\ PLANTING �\ TYP. \ / SE 0 DECK, WI B SIDE — SAND SET TRAVERTINETONE PAYERS ON 919 TONE BASE --� • N \\ \\ / PLANTING 1 / / / / / A/C A/G B \ \ / / / SEAL L9 / b x 12 SOLDIER BORDER SEGMENTAL WALL FAGS POOL PLANTER 16 x Ib ON 45' POOL RT E - EQUIPMENT TRAVERTI E MUD SET 0% ON CONCRETE SUBBASE 41' -0" p I / eay 9, -0. AREA OF FILL b" MEXICAN BEACH PEBBL BAND BEHIND COPING 0' ry'�II gg TROUGH TWO STORY FRAM �sPA� INFINITY x 3 i/ N LU ~ 21za' + RESIDENCE alta ' + o 8 w z O L8 0 1629 — POOL WALL / / W q FFE-21.25 GRANITE WEIR GAP n/ q Z 1 u / Lu Q 0 Q :-3z Lu lid / W ('Q U 3 CM TRAVERTINE BULLNOSE 3 CM TRAVERTINE BULLNOSE CEA. SIDE) SPA COPING - I' x 2' I' 2' / / ( W N Z 5 POOL COPING - x / \ N ! Q POOL DECK - L9 / SEGMENTAL WALL N / � / \ \ Z � (- TRAVERTINE MUD SET AREA FILL FACE / \ Q PAVERSOF AVER ON CONCRETE SE Ib x Ib ON 45' RTINE STEPS b x 12 SOLDIER BORDER—,\ TRRA E '919 I / O \ I I /l PROPOSED / DATE I PL/NTING \ \\ P. • 1I / 19 5' $ 19.0 80' I i.0'/ I� 0I 150' �1' 14.0' + -f I + I \\ NERW�EN WALL �_sANp SET TRAVERTINE-- I 13.0' I SHEET TITLE 80' LF PAVERS ON 919 STONEBASE Lg + J I + + + \ x 18.1 SAND SET CONCRETE PAVER PATH POOL LAYOUT PLAN DATE 188UED APRIL S, 2016 REVISIONS DEG. 1, 2016 ONE STORY FRAME 1619 SALE I"4' oN 24"x36" NORTH SHEET L5 OF 12 CONSTRUCT WALL IN S' PANELS FOR FRANGIBILITY TWO STORY FRAME 2128' RESIDENCE I(o29 FFE-21.28' g�C�EN ""WALL _SAND SET TRAVERTINE - LJ . LF PAVERS ON SIS STONE EASE TWO STORY FRAME 1633 EASE �� TPL,47NTF-R+ 20.82' 21.5' 19.'15' + � SPAS 2128' + 20.95' -+- L — J 21.5' 20.82' + / 1932' 19.0' 8.2 + i+ x 18.1 ll-� ONE STORY FRAME 1619 x 15.7 1 IONOEEIEY SNCRTTDCKT74 G2.RED5AE 13.5' 14b5' TROUGH INFINITY POOL 12' x 32' + 20.58' SHOTCRETE j 1 + POOL WALL WEIR CAPRANITE 14.854 � 13.5' N I � I � I � 20.82' 20.82' M � I 1 I � 1 -SAND SET CONCRETE PAVER PATH EUT�4ENIC8 STUDIO 9?.AND ARCHITECTURE II.AITY PLANNING ULAN DESIGN 604 333 1483 lullmo ooc mca"Aet 'LORIDA REG. NO.1160 3EORGIA REG. NO. 668 POOL GRADING PLAN DATE ISSUED APRIL 5, 2016 REVISIONS SCALE 1''=36 I" 2 SHEET L&OF 12 42" HT., 2" 55T FENCE PIPE, 4' O.G. W/ 5 STRAND SST GABLE AAPPROACHINNG�HOSIDES — TWELVE COURSE SEGMENTAL WALL 'COMPAC' RETAINING WALL BLOCK BLACK GRANITE INFINITY EDGE SHOTCRETE INFINITY EDGE POOL WALL) SPILLWAY COLLECTION TROUGH A ELEVATION EAST FADE OF INFINITY POOL LS RESIDENCE I _. _.. 32' - 8' x 8 SPA SECTION a INFINITY POOL 42" HT., 2" SST FENCE PIPE, 4' O.G. 2082' BACKFILLED BEACH SAND PpLLACED IN LIFTS WATER PACKED A5 WALL 15 CONSTRUCTED MIRAGRID 3XT GE05YNTHETIG ALTERNATE COURSES SEGMENTAL WALL TREMRON C,OMPAC'' C SNCRET BLOCK 16.49' PINS FINISHED GRADE 3' WIDE x 12" DEEP GRAVEL WALL 545E FOOTING, STEPPED EVERY 5', 1 COURSE _ 12' - 0" TRAVERTINE POOL DECK LUANDA BAY GLA55 WATERLINE TILE BAND POOL STEPS P O O L • 11.0' e" POOL eHELL BLUE PEARL PEBBLE -TECH PLASTER COAT W/ CRUSHED - �. ABALONE SHELL 145' P. 14.35' SEE STRUCTURAL DWGB. - FOR POOL GRADE BEAM 4 PILE SPECIFICATIONS 12' - 0" -.. WM=l GLA55 WATERLINE TILE TRAVERTINE STONE POOL DECK . . BAR DO O.C. i�4ea4c - ♦`♦♦♦` ♦�;�♦`�M ice♦ DEBRIS FOOL S)kELL ♦♦`♦-♦-♦`♦ .♦�♦ .♦�♦ ♦♦` ♦ ♦ ` -►4♦ BAR, 16" 0. C., 4' LENGTH IMBED )EDFIINEO POUREDI SUB SLAB BLUE PEARL PE551LE-TECH _MIRAGRID ALTEF NATE COURSES PLASTER COAT 6♦ `♦♦♦`♦♦♦`♦♦♦`♦♦,`♦♦♦,DEPTH VARIES►♦♦ `♦♦ `♦♦ `♦♦ `�♦ �l�♦-` 8"h x IS"W x 12"d -.--FINISHED GRADE (VARIES) 15ACKFILLED BEACH SAND II - e - PLACED IN LIFTS WATER PACKED -1 AS WALL is CON�TRUCTED IP STRUCTION 3' WIDE x 12" DEEP GRAVEL SEE STRUCTURAL DWG5. FOR POOL GRADE BEAM 4 PILE SPECIFICATIONS SECTION a INFINITY FOOL SEGMgNTAL LUALL -INFINITY EDGE (3) 2" x 3" CONCRETE AIRIFIER 5UMPOUT5 - 10" W x 12' LONG BLACK GRANITE SPILLWAY COPING (3) 2" x 3" CONCRETE AIRIFIER BUMPOUT5 — 10" WIDE COLLECTION TROUGH TOP OF SEGMENTAL WALL TW 20.41' 3" 11,01' �1.�11P„IIPI� h -m -Ili 42" HT„ 2" 55T FENCE PIPE, 4' O.G. W/ 5 STRAND SST GABLE TWELVE COURSE TREMRON SEGMENTAL WALL 'COMPAC' RETAINING WALL BLOCK SEGMENTAL WALL STONE: TREMRON KEYSTONE 'COMPAC III' ,- 8" H x 18" W x 12" D WEIGHT - 15 Ube. COLOR: 'PRAIRE' TOP OF SEGMENT x - I WALL BASE FOOTING. LINE T 3.g3�_g a TRENCH WITH FILTER FABRIC4' 113E ORIGINAL GRADE SAND, FREE OF ORGANICS 4 CONSTRUCTION DEBRIS ELEVATION 5EC;MENTAL WALL 42" HT., 2" SST FENCE PIPE, 4' O.G. LS -►4♦ BAR, 16" 0. C., 4' LENGTH IMBED )EDFIINEO POUREDI SUB SLAB 3XT GE05YNTHETIC _MIRAGRID ALTEF NATE COURSES SEGMENTAL WALL-TREMRON KEYSTONE COMPAC III' WALL _ BLOCK W/ FIBERGLASS PINS 8"h x IS"W x 12"d -.--FINISHED GRADE (VARIES) SEGMENTAL WALL TREMRON _ CONCRETEBLOCK WG/FIBERGLA55 3' WIDE x 12" DEEP GRAVEL WALL ®ASE FOOTING. LINE TRENCH WITH FILTER FABRIC ORIGINAL GRADE SAND, FREE OF ORGANICS 4 CONSTRUCTION DEBRIS EUTHENICS STUD 10 LAND ARCHITECTURE COMMUNITY PLANNING URBAN DESIGN 904 333 1483 ksllmoreecomuetnel Fi_ORIDA REG. NO. 1*0 GEORGIA REG. NO. 668 La U z w Q W z o AL LLI W Q Lu W a' ~ z Q Lu U- 0 - POOL SECTION5 DATE ISSUED APRIL 5, 2016 REIASION5 DEC 1 2016 La or 12 COASTAL CONTROL I--- CONSTRUG ION LINE / TWO STORY FRAME RE NGE ON9 STORY FRAME 1633 W I (GARAGE LOT 1 WALL MOUNTED z I STAIR LIGHTS Lu 4' MTNG. HT. Ex8T b" A/C z LIVE'6 "'— WALL MOUNTED U I PE SCONCE LIGHTS 6' MTNG. HT. UNDERWAT Lu ER i i WALL MOUNTED POOL LIGHTS SCONCE LIGHTS SIDENCE 6' MING. HT. c TWO STORY FRAME �9bt FL OR GARAGE COURTYARD RESIDENCE POOL Ind Fl.�ooR - RESIDENCE COURTYARD 7 x8.01 IFFE-21.26' p ELEV. 19.85' 1 FFE-21.28' I I ELEV. 21.0' i O I GA E LEVEL HOODED STAIR ELE . 8.80' I `PATH LIGHTS, 15" HT. I i O11 x IERION CONTROL CONTROL LINE CONSTRUCT ON ONE ASTAL STORY FRAME / RESIDENCE / I 1619 / I SEE SUPPLIED CUT SNEETS AOR LIGxNTING� PRODUCTS SPEGIPICS LIG3I4TING; SCHEDULE / KEY MOUNTING WILDLIFE QTY. SYM +-IEICsHT CERTIF NUMBER LOCATION 2 8 O 16 5 j17 LIGHT DESCRIPTION LICsHT BULB TYPE INTELLIBRITE 5 G UNDERWATER POOL AND 12 VOLT, 26 WATT, AMBER LED 18" BELOW POOL COPING 2015-015 1 - IN POOL I - IN SPA SPA LIGHT THOMAS TURTLE LIGHT WALL SCONCE 120V, PAR 20 LED, AMBER, 13 W 6' HT. 2001-028 WALL SCONCE GAT i 51-9210-1 BEACHSIDE LIGHTING - R3A 12 V, MR 16, LED, 5W AMBER 16,. 2010-014 PLIGH SOS CAT " P5HO105R CAT i LED 1156 RED KIGHLER DECK DOWN LIGHT -15063 -OB 12 VOLT, 6.5 WATT LED 4' COURTYARD STEP WALLS RWA w GAT. 16110GRY21 15593GLR STEE11L EUTHENIC5 5TUD 10 904 333 1483 kollmorNeomce6tno1. FLORIDA REG. NO. (Iia GEORGIA REG. NO. iie U Q ol z z o F � Lu Luul Q U Q �3-ZwLu ED m F- N F- LU LL L LIGHTING PLAN DATE IOWED JULY 15, 2016 I-VIBIONB I7EG 1 91016 SCALE oN 24" x K" L12OF 12 VGB Series Features For single or multiple drain use (see installation instructions for plumbing, hydrostatic valve/drain pipe and single or multi -pump connections) Single Floor: 236 GPM at 3.4 fps Wall: 136 GPM at 1.9 fps Floor/wall: 106 GPM at 1.5 fps Floor/wall: 70.4 GPM at 1.0 fps 22.6 square inch opening #316 stainless steel screws PVC sump (standard) Manufactured from superior UV -resistant engineered polymers Three ports: bottom 21/]" OD, 2" ID S/S; inside 2" threaded FPT; two 2" threaded plugs included All components meet or exceed ANSI/APSP 16.2011 and NSF/ANSI 50-2009a national standards and ASTM G154 UV testing exposure Orange disposable plastic pre-gunite/ plaster insert keeps debris out and retains sump shape during construction Does not require use of transition glue Replace every five years from the date of installation 4 per case STANDARD COLORS 101 104 . 102 ■ 105 103 108 Also available as sump only p/n 32CDPxxx 4 per case 32" Channel Drain Anti -Entrapment Suction Outlet Cover and PVC Three -Port Manufactured Sump The AquaStar line of suction outlet covers, compliant with the Virginia Graeme -Baker Pool and Spa Safety Act (ANSI/APSP 16-2011 and NSF/ANSI 50-2009a) The Unblockable! With sump (concrete pools) Part # 32CDAVxxx --- 32-19/32 5116 3-27/32 j 5/16 4.11/32 10 I 10 2-112" spigot x Z" socket x 2"NPT Two drains in one! Also available cover only 1. 32" three -port manufactured sump bucket without sump/frame 2. 32" anti -entrapment suction outlet cover p/n 32CDAVNFxxx 3. 32" channel drain, plaster shield 40 per case 4. 2" NPT plug, qty 2 5. #10 x 3/4" flat head Phillips type -a screw, 316 ss, qty 16 VGB 2oo8 Compliant P877-768-2717 F877 -276 -POOL Outside the US: P +1-805-620-5060 F+1-949-336-1940 info@aquastarpootproducts.com www.aquastarpoolproducts.com INTELLIPR®° VARIABLE SPEED HIGH PERFORMANCE PUMP STA- R ITE Includes 2 in. NPT Slip Unions IntelliPro Variable Speed Pump Protected by U.S. Patent No., 7,686,587. 7,854,597, 0611,430, D606.562; 8,043,070; 8,469,675; 8.573.952 and Patent Pending and all corresponging foreign counterparts. IntelliPro Variable Speed pumps combine variable drive technology, onboard digital intelligence, and permanent magnet motors (used in hybrid cars) to reduce pump-retated energy costs by up to 90%! Ordering Information Primary Port Size Carton Fulf Load kW HP SF SFHP FRED. Listings and (NPT) Wt. ILbs.) Product Description Voltage Amps Certifications' • UL 1, NSF CSA 3, 2in. x2in. 47 P6E6VS4H-209L IntelliSpeed fable 230 16 3.2 3 1.32 3.95 50hz/bOhz APSP` Speed 1 521109 IntelliCom 2 - Rated 9 - 24 VDC with 4 inputs 2 350122 Communication Cable - 50 It. - Included with pump 'UL' indicates that pump bears a specific UL mark signifying evaluation to U.S. Standards UL1081 for Permanently Connected Swimming Pool and Spa Pumps and to Canadian Standards CAN/CSA C22.2 No. 108-01 Liquid Pumps For Swimming Pools only (Enclosure 31. 'NSF' indicates that pump bears a NSF mark signifying evaluation. to NSF Standard 50 For Selt-Priming Centrifugal Pumps For Swimming Pools Only. 'CSA' indicates that pump bears a CSA mark signifying evaluation to Refer to catalog page 45 for a selection of 2 -Pole GFCI breakers which offer 6 milliamp personnel protection while meeting NEC 2008 Standards for Pool Pumps. Canadian Standards CAN/CSA C22.2 No. 108-01 Liquid Pumps For Swimming Pools Only (Enclosure 31. 'APSP' Pump has been evaluated to ANSI/APSP/ICC-15 and California Title 20 and is certified to use on Residential Swimming Pool Filtration Systems. s Product may have been evaluated to other state and local regulatory standards. Listing status may change. Always confirm status with appropriate agency if in doubt. HighLights Featured �4. • Ability to program exact pump speeds for specific .C0F ® operations - filtering, heating, cleaning, spa jets, water select features and more -reduces energy costs up to 90% E , - c i • 8 speed settings and on -board scheduling LCD screen PENTAIR with keypad for easy programming • Uttra-efficient permanent magnet motor design reduces noise and vibration for greater efficiency and 0— longer pump life • Fully compatible wtih IntelliTouch®, EasyTouch®, SunTouch® Automation and other pool control systems Appliance • Operates seamlessly on 50 hz or 60 hz input power. when operating on 50hz or 60 hz. Efficiency Flow/speed are constant b- Database • Includes 2 in. NPT Slip Unions Protected by U.S. Patent No., 7,686,587. 7,854,597, 0611,430, D606.562; 8,043,070; 8,469,675; 8.573.952 and Patent Pending and all corresponging foreign counterparts. IntelliPro Variable Speed pumps combine variable drive technology, onboard digital intelligence, and permanent magnet motors (used in hybrid cars) to reduce pump-retated energy costs by up to 90%! Ordering Information Primary Port Size Carton Fulf Load kW HP SF SFHP FRED. Listings and (NPT) Wt. ILbs.) Product Description Voltage Amps Certifications' • UL 1, NSF CSA 3, 2in. x2in. 47 P6E6VS4H-209L IntelliSpeed fable 230 16 3.2 3 1.32 3.95 50hz/bOhz APSP` Speed 1 521109 IntelliCom 2 - Rated 9 - 24 VDC with 4 inputs 2 350122 Communication Cable - 50 It. - Included with pump 'UL' indicates that pump bears a specific UL mark signifying evaluation to U.S. Standards UL1081 for Permanently Connected Swimming Pool and Spa Pumps and to Canadian Standards CAN/CSA C22.2 No. 108-01 Liquid Pumps For Swimming Pools only (Enclosure 31. 'NSF' indicates that pump bears a NSF mark signifying evaluation. to NSF Standard 50 For Selt-Priming Centrifugal Pumps For Swimming Pools Only. 'CSA' indicates that pump bears a CSA mark signifying evaluation to Refer to catalog page 45 for a selection of 2 -Pole GFCI breakers which offer 6 milliamp personnel protection while meeting NEC 2008 Standards for Pool Pumps. Canadian Standards CAN/CSA C22.2 No. 108-01 Liquid Pumps For Swimming Pools Only (Enclosure 31. 'APSP' Pump has been evaluated to ANSI/APSP/ICC-15 and California Title 20 and is certified to use on Residential Swimming Pool Filtration Systems. s Product may have been evaluated to other state and local regulatory standards. Listing status may change. Always confirm status with appropriate agency if in doubt. KINE 90 80 V 70 3 0 60 W C .a to 50 u CT 40 A 30 20 10 0 INTELLIPRO° VARIABLE SPEED HIGH PERFORMANCE PUMP (CONT'D) Intel iPro Variable Speed Pump Dimensions and Performance MAX SPEED- 3450 RPM SPEED - 3110 RPM 1 FACfORYPRESET SPEEDS -3110 RPM -2350 RPM -1500 RPM -750 RPM SPEED 3 - 2350 RPM I SPEED 2 -150D RPM SPEED 1- 750 RPM 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 Plow Rate in US GPM Note: IntettiPro VS+SVRS minimum speed is 1100 RPM 1075 See page 534 for replacement parts. SYSTEM:2T11 MODULAR MEDIA FILTERS PEM SERIES FIIJERS System:2 Modular Media Fitters PLM Series Featured Hightights • Typical Installation - aboveground pools, inground pools, and inground hot tubs • Quality Construction - Durable two-piece tank housing constructed of rugged ABS thermoplastic to ensure a tong -tasting tank life • Easy Access- Posi-Ring' Locking Ring provides fast access to tank internals • Innovative Design - The innovative balanced flow design first introduced with the System :3 Mod Media fitter is now available in the smaller System:2 fitter, virtually maintenance -free operation for pools of all sizes • Low Maintenance -Complete media coverage combined with shallow pleats means greater dirt holding capabilities, resulting in longer filter cycles and less cleaning • Large Drain Plug - Filter includes 2 in. NPT Drain ports, which are provided with reducer bushing and 1-1/2 in. drain plug Sta-Rite's modular media filtration is the perfect match for both the inground and aboveground pool markets. Advances in media technology and balanced flow design provide dirt -loading capabilities up to 15 times greater than sand filters of equivalent size. Virtually maintenance -free operation for today's pool owner. The small diameter footprint makes the System:2 fitter a perfect fit for new and retrofit installations. Modular Fitter Tanks allows for quick change of fitter medias without changing the tank. Contemporary style and matte black finish looks attractive in any pool setting. Ordering Information Turnover Capacity (in Gallons) Product Effective Fitter Flow Rated (Flow Rate x 60 x Flours) Tank Port Carton Area (Sq. Ft.) GPM (Sq.. Ft.) Size Wt. (Lbs.) 6 Hour 8 Flour 10 Hour t • MEDIA FILTER - PLM SERIES PLM100 100 38-100 14-36,000 18-48,000 23-60,000 2 in. 41 PLM125 ........... _ 125 47-125 17-45,000 22-60,000 28-75,000 2 in. 42 PLM150 150 56-150 20-54,000 27-72,000 34-90,000 2 in. 43 PLM175 175 - 66-150 24-54,000 31-72,000 39-90,000 2 in. 44 PLM200 200 75-150 27-54,000 36-72,000 45-90,000 2 in. 45 PLM300 300 113-150 41-54,000 54-72,000 68-".000 tin. 53 Based on NSF recommended flow rate for commer6at at .375 GPM per Note: Operat:nq Limits — maximum continual operating pressure of square foot. 50 PSI. Pool/spa (batherl applications, maximum operating water Note: No backwash valve required. temperature linternat fitter) 104°F l40°C). SYSTEM:2T"" MODULAR MEDIA FILTERS (CONT'D) PEM SERIES FILTERS Ordering information Description Garton Wt. (Las.) 27002-0100S 100 Sq. Ft. Replacement Module for PLM100 11 _.. _.... ...... ... 27002-0125S 125 Sq. Ft. Replacement Module for PLM125 27002-0150S 150 Sq. Ft. Replacement Module for PLM150 12 27002-01755 175 Sq. Ft. Replacement Module for PLM175 13NET 27002-02005 200 Sq. Ft. Replacement Module for PLM200 14 27002-0300S 300 Sq. Ft. Replacement Module for PLM 300 14 U78 -820P 2 in. x 1-1/2 in. Pipe Reducer Bushing 8 oz. 27001-0130S Spring Check Valve 1 20 18 16 14 c 'Q 12 10 8 d a` 6 4 2 0 MAX. FLOW . RATEPLM125 MAX. FLOW RATE PLM 100 0 10 20 40 60 80 100 120 140 160 Flow Rate in Gallons per Minute PLM 100, PLM125, PLM 150. PLM175, PLM200, PLM300 Dimensions and Performance 11� All dimensions shown in inches. See page 393 for replacement parts. "IS 300-29x 300-99 300-00 no Y Y Rainbow Chlorine and Bromine Feeders Years of customer use and satisfaction have proven Rainbow feeders to be the performance leader in pool & spa chemical dispensers. Ordering Information * 300 and 320 series feeders available in clear amber for easy tablet level monitoring • Completely enclosed system - no special venting required • No escaping gases 50 PSI maximum operating pressure In -Line Feeders ® 320 Series. For per instattation in return tine of new or existing pools or spas. Installs in return line on pressure side of pump downstream of all equipment. Standard with 2 in. slip PVC fittings and adapters for 1-1/2 in. Off -Line Feeders • 300 Series. Retrofits into existing pools or spas. Operates on pressure side of pump. Uses 1/4 in. feeder hoses, control valve and fittings. Output rating for Bromine is not NSF Certified. Product Model Description Carton Qty. 320 no Y Y Rainbow Chlorine and Bromine Feeders Years of customer use and satisfaction have proven Rainbow feeders to be the performance leader in pool & spa chemical dispensers. Ordering Information * 300 and 320 series feeders available in clear amber for easy tablet level monitoring • Completely enclosed system - no special venting required • No escaping gases 50 PSI maximum operating pressure In -Line Feeders ® 320 Series. For per instattation in return tine of new or existing pools or spas. Installs in return line on pressure side of pump downstream of all equipment. Standard with 2 in. slip PVC fittings and adapters for 1-1/2 in. Off -Line Feeders • 300 Series. Retrofits into existing pools or spas. Operates on pressure side of pump. Uses 1/4 in. feeder hoses, control valve and fittings. Output rating for Bromine is not NSF Certified. Product Model Description Carton Qty. Carton Wt. [Lbs.] Holds 11 targe or 98 small Bromine or stow dissolving Trichlor tablets. R171096' 320 Treats 6,500 to 27,000 gallons bottom teed and 18,000 to 70,000 gallons 1 30 top teed. Holds 11 targe or 98 small Bromine or stow dissolving Trichtortablets. R171218' 320C Treats 6,500 to 27,000 gallons in a bottom feed configuration and 18,000 1 30 to 70,000 gallons in a top feed configuration with see-through amber body R1710161 300 Holds 11 large or 98 small tablets. Treats 12,000 to 48,000 gallons. 1 26 R17102T 300C Holds 11 large or 98 small tablets. Treats 12,000 to 48,000 gallons with 1 26 see-through amber body. R171026 302 Spa feeder. Includes spa chamber. Treats 500 to 2,000 gallons. 1 28 Holds 15 small tablets_ R1710561 300-19 Spa feeder includes double -capacity 19 in. chamber. 1 5 Treats 13,000 to 52,000 gaiions. R1710661 300-29 Spa feeder includes triple -capacity 29 in. chamber. 1 6 Treats 14,000 to 57,000 gallons. Heavy duty 1/2 in. controtvalve and tubing optimizes flow and erosion to R1710707 300-29X provide larger amounts of sanitizes Dispenses 8.5 tbs. of 1 in. Trichlor 1 8 Tablets in 24 hours. Holds 29 targe or 237 small tablets. Treats 80,000 to 322,000 gallons. High capacity for 1 in. hard plumbing installations Holds 15 lbs. of R171215' HC -3315 tablets. Treats up to 20,200 gallons with Bromine and up to 97,600 gallons 1 9 with Trichtor. High capacity for 7 in. hard plumbing installations. Holds 30 tbs. of R1712301 HC -3330 tablets. Treats up to 40,000 gallons with Bromine and up to 160,000 1 12 gatlonswith Trichtor. High capacity for 1 in. hard plumbing installations. Holds 40 tbs. of R1712401 HC -3340 tablets. Treats up to 61,000 gallons with Bromine and up to 332,000 1 14 gallons with Trichlor. Nota_ Rainbow Automatic ChlorineiBromine ieeders are #or use wi,.h siow dissuiving trn.:htor or bromine tablets only. NSE }fisted for public or res+dentia? use in Swimming Pools, Spas or Hot Tubs using t" Trichl r tablets and when used with a flow indicating device such as a Rainbow Model, # R172030. Output rating for Bromineis.not NSE Certified. See pages 578-582 for reptacernent parts. GLOB RITEO" WHITE AND COLOR LED LIGHT UNDERWATER LED EIGHTS FOR S,AIII~ MING POOLS AND SPAS Featured Highlights • The brightest and most efficient LEDs available GloBrite LED Light • Can be placed in as little as 4 in. Fiberglass Niche e l e c t of water even in the floor pointing up • Does not require grounding or bonding > PertTAlR for quick and easy installations • 5 brilliant fixed colors and 7 pre-programmed light shows • Compatible with IntelliTouch® or ice• C!oBrte LEG might EasyTouch® Controt Systems for Vinyl Niche advanced control features • Compatible with gunite, fiberglass GloBrite LED Light and vinyl pools Concrete Niche GloBrite LED Lights use advanced technology for energy-efficient, ;high quality tight displays, delivered with enhanced LED brightness and superior optics, white using 18% less energy than other shattcw water LED lights. Gtobr ite lights are compatible with lnteltiTouch and EasyTouch control systems and inteLliBrite 5g LED pool tights. GloBrite LED lighting is a brilliant way to showcase and enhance pool features like baja shelves; steps, beach entries and shallow water features_ (vote: Only GtoBrite white Lights have two dimming levels. GtoBrite cotor tights cannot be dimmed. Card Carton Carton Product Voltage Wattage length Qty. Wt. (Lbs.) (Ft.) 602053 12 15W 30 1 5 602054 12 15W 50 1 6 602055 12 15W 100 1 9 602056 12 19W 15n 1 12 Product Description Ordering Information Carton Wt. (Lbs.) 620040 Gunite Mcge for Gto8rite (includes white, blue, black, grey and tan rings) Cord Carton Garton Product Voltage Wattage Length Qty. Wt. (Lbs.) 1.3 620093 Fiberglass Niche for GtoBrite (blue) (Ft.) 1.3 620094 602102 12 15W 30 1 5 602103 12 15W 50 1 6 602104 12 15W 100 1 9 602105 12 15W 150 1 12 Product Description Carton Qty.. Carton Wt. (Lbs.) 620040 Gunite Mcge for Gto8rite (includes white, blue, black, grey and tan rings) 1 1.3 620039 Vinyl Niche for GloBrite (includes white, blue, and grey ringsl 1 1.3 620041 Fiberglass Niche for GloBrite (white) 1 1.3 620093 Fiberglass Niche for GtoBrite (blue) 1 1.3 620094 Fiberglass Niche for GloBrite (grey) 1 1.3 619993 1 GloBrite Color 100 ft. with 30OW Transformer + Gunite Niche 1 25 619994 2 GtoBrite Color 100 ft. with 30OW Transformer + 2 Gunite Niches 1 40 620051 1 GloBrite Color 100 ft. with 30OW Transformer+ Fiberglass Niche i 25 620052 2 GloBrite Color 100 ft. with 30OW Transformer + 2 Fiberglass Niches 1 40 620080 1 GloBrite Color 100 ft. with 30OW Transformer +Vinyl Niche 1 25 620081 2 GloBrite Color 100 ft. with 30OW Transformer + 2 Vinyl Niches 1 40 GLOSRITE° WHITE AND COLOR LED LIGHTS (CONT`D) DNDERWAi ER LED LIGHTS FOR SVVIMMING POOLS AND SPAS Ordering Information 619963 12V -14V 30OW 620314 GtoBrite LED Light Glare Shield Act Pentair UL Listed underwater tights are certified for use in fresh water with up to 6,000 ppm salinity. Dimensions and Certifications See page 488 for reptacernerit parts. 12 Carton My. Carton Wt. (Lbs.) Product Description 30OW Transformer+ 2 Gunite Niches 1 40 602106 2 GloBrite White 100 ft. with 602707 2 GtoBrite White 100 ft. with 300W Transformer+ 2 Fiberglass Niches 1 40 602708 2 GtoBrite White 100 ft. with 300W Transformer. 2 Vinyl Niches v 40 • o >'. s10 N 619962 12V -14V 100W 1 12 619963 12V -14V 30OW 620314 GtoBrite LED Light Glare Shield Act Pentair UL Listed underwater tights are certified for use in fresh water with up to 6,000 ppm salinity. Dimensions and Certifications See page 488 for reptacernerit parts. 12 SQ110 S0120 SQ155 SQ175 SQ166R BTU 80/80/80* 100,000 113,000 135,000 143,000 126,000 80/80/63'* 93,000 106,000 127,000 134,000 120,000 80/50/63** 63,000- 73,000 86,000 90,000 71,000 Coefficient of Performance 80/80/80* 6.1 6.1 6.4 6.5 5.6 80/80/63** 5.7 5.7 6.0 6.1 5.3 80/50/63** 4.1 4.0 4.3 4.3 4.0 Operates down to OF mid to low 40s mid to low 40s mid to low 40s mid to low 40s mid to low 20s Refrigerant R410A R410A R410A R410A R410A Electrical Heat or Heat & Cool H H H H H& C kW Input 4.8 5.5 6.2 6.4 6.6 Voltage/Hz/Phase 208-230/60/1 208-230/60/1 208-230/60/1' 208-230/60/1• 208-230/60/1• Minimum Circuit Ampacity 39.8 41 A 41.4 41.4 41.4 MinmumlMaximum Fuse Size 40/60 50/60 50/60 50/60 50/60 Waw Flow Minimum/Maximum (gpm) 30/70 30/70 30/70 30/70 30/70 Physical Weight (lbs) 257 282 293 328 255 Size (lengthxwidthxheight) 37"x34"x41" 37"x34"x41" 37"x34"x45" 37"x34"x45" 37"x34"x45" Shipping Weight (Ibs) 315 340 355 390 315 Size (lengthxwidthxheight) 40"x36"x46" 40"x36"x46" 40"x36"x50" 40"x36"x50" 40"x36"x50" Sound t vel iDiit►s a# 10 ft. ;: 5500 55 dB 55 dB 55 dB 55 dB