Loading...
2139 SEMINOLE RD - PERMIT PLRS18-0131 .Y j y�j1j CITY OF ATLANTIC BEACH ? 800 SEMINOLE ROAD _ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 PLUMBING RESIDENTIAL - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: PLRS18-0131 Description: abandon septic& install grinder pump into existing sewer Estimated Value: 2150 Issue Date: 5/21/2018 Expiration Date: 11/17/2018 PROPERTY ADDRESS: Address: 2139 SEMINOLE RD RE Number: 169515 0500 PROPERTY OWNER: Name: Camille Adams Address: 2139 SEMINOLE RD ATLANTIC BEACH, FL 32233-5921 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: Clay County Master Plumbing LLC Address: 449 Arthur Moore Dr GREEN COVE SPRINGS, FL 32043 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE"RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. PLUMBING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 Pl�(L-,S 18 Qj JOB ADDRESS: ` 1 PERNUT# NEW OR REPLACEMENT INSTALLATION: Project Value$ ca TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System RE-PIPE: TYPE of FIXTURE QTY TYPE of FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans) ❑ Lawn Sprinkler System-Number of Heads ❑ Well ** VRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection." Other A/�A/rlDo/t/ s��fiic ��ls ,/ Gie�%yae� I°��nso iiy�ci `xi S�'i`/✓���%/eP Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violMe— e provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name QQ-PA 1 0, M Phone Number �D — 1 J0 n om — U Plumbing Company C� COU Mas-�--�e K Office Phone Co. Address: 'IDlg Cin ar(-c 5 l lRC ��- City �� <e -Zip 3 License Holder(Print): �1C�� �5 e Certification/Registration# Notarized Signature of License Holder 7JENNIFERSw nd subscribed before me th sday of L 20 JOHNSTONMY COMMISSION#GG 042984 EXPIRES:Octobet27,2o2u Signature of Notary Public ••o Bonded7hruNotaryPublicUndervxiters , PERMIT #::16-SJ-18.48710 STATE OF FLORIDA APPLICATION #:AP 1345573 DEPARTMENT OF HEALTH DATE PAID: " ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: SYSTEM {y . RECEIPT #: DOCUMENT #:-PRI 117777 . CONSTRUCTION PERMIT FOR:: OSTDS Abandonment. APPLICANT: Camille Adams. PROPERTY ADDRESS: 2139 Seminole Rd Atlantic Beach,FL 32233 LOT: 1 BLOCK:. SUBDIVISION: PROPERTY ID #: 169515-0500 [SECTION, TOWNSHIP, RANGE, PARCEL. NUMBER] [OR TAX ID NUMBER]'. . . SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH ..SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S:, AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF, SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS-, WHICH: SERVED AS A BASIS FOR ' ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY. RESULT IN THIS PERMIT BEING MADE NULL AND VOID: ISSUANCE OF, THIS PERMIT DOES NOT EXEMPT THE. APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN. AND SPECIFICATIONS T L ] GALLONS / GPD CAPACITY A -I ] GALLONS / GPD CAPACITY GALLONS. GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K I I GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] D [ ] SQUARE FEET. SYSTEM R [. I SQUARE FEET SYSTEM A TYPE SYSTEM: [ ] .STANDARD [ ] FILLED ( ] MOUND [ ] I' CONFIGURATION:. [ ] TRENCH [ ] BED [ ] N F LOCATION OF BENCHMARK: I ELEVATION OF-PROPOSED SYSTEM .SITE [ ] [ / ] [ABOVE/BELOW IBEN CHMARK/REFERENCE POINT E BOTTOM .OF DRAINFIELD TO BE ] LABOVE/BELOW]'BENCHMARK/REFERENCE POINT L D FILL REQUIRED- [ 0.00.] INCHES. EXCAVATION.REQUIRED: [ ] INCHES Have the:tank abandoned in accordance with the following procedures:.(a)The tank shall be pumped out:(b)The bottom of o.: the.tank shall be opened or ruptured,.orthe entire tank collapsed so as to prevent the tank from retaining water;and(c)The T_ tank shall be filled with clean sand or other suitable:material,and completely covered with soil'.Have the system inspected H :by the health department after it has been pumped and ruptured but before it is filled with sandand covered. E R SPECIFICATIONS BY: John G' CCorr�dy ,{ TITLE' Environmental Specialist LI APPROVED BY: TITLE: Environmental Specialist II Duval CHD John'G Cordy DATE, ISSUED: 05/18/20,18.. -. EXPIRATIONDATE 08/16/2018 DH 4016, 08/09 (Obsoletes all previous editions wfiich may not be used) Incorporated: 64E-6.003, FAC: Page 1 of 3 v 1.1.4 AP1345573 SE-1 omnVoreo den Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 11131pol ;;G.' N' � 1j ��11■III�C� 11� 2448LSG/LSGX - Series Dimensional Data 0 30 3/16" [77cm] FIBERGLASS OR STEEL COVER � � �� (FIBERGLASS SHOWN) -a � ° DISCHARGE PIPE 0 32.9in JB230 [84cm] JUNCTION BOX WITH 6-20P 230 VOLT RECEPTACLE 12 • n 18.Oin [30cm] 4.1 in [46cm] _ [10cm] ALM-2W OUTDOOR 4" FIBERGLASSWATER INLET HUB AND 48" ALARM FERNCO SEAL [122cm] 115 VOLT 5.9in [15cm] ANTI FLOATATION COLLAR �24 61 cm [ ] �o INSIDE DIAMETER ❑ 03011 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED RN THIS [76 c m] DRAWING IS THE SOLE PROPERTY OF 2448 SERIES DIMENSIONAL LIBERTY PUMPS.ANY REPRODUCTION DWG.NO. IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LIBERTY PUMPS 3¢e DATE: 2/16/12 R� IS PROHIBITED. PIA A APPLICATION DO NOT SCALE DRAWING SCA- LB SHEET I of 7 2448LSG_P2 R4/2/2012 ®Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. PII PS. 0 4„ [61 cm] TANK 0„ [76cm] ANTI-FLOAT ELECTRICAL CONDUIT COUPLING 2" NPT 101, 12" [25cm] [30cm] 18.Oin ® ® - [46cm] GR20 GUIDE RAIL DISCONNECTED VIEW SEE DETAIL NEXT PAGE r,— Ll 2 „ [53cm] 1 ALARM [33cm] FLOAT OFF FLOAT d PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF 2448 SERIES DIMENSIONAL LIBERTY PUMPS.ANY REPRODUCTION DWG.NO. IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LIBERTY PUMPS ScE DATE: 2/16/12 RE. IS PROHIBITED. A A APPLICATION DO NOT SCALE DRAWING SCALE:IA SHEET2OF3 2448LSG P3 R4/2/2012 ®Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. P>tnnps� 3.6in [9cm] if 6 5/8" 5.2in [17cm] [ 13cm] 17.Oin [43cm] UPPER PIPE. GUIDE BRACKET 20.7in [53cm] 5.2in V� [13cm] 9.Oin [23cM] 1011 [25cm] 19.5in .[50cm] ° o GR20 GUIDE RAIL BASE PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE PROPERTYOF LIBERTY PUMPS.ANY REPRODUCTION DWG.NO. 244 8 SERIES EOICS DIVCNSIONAL IN PART OR AS A WHOLE WITHOUT THE 6 WRITTEN ITED�ION OF LIBERTY PUMPS Stw DATE 2/27/12 Rte. M A APPLICATION DO NOT SCALE DRAWING "SCALE:1d SHEET I of I 2448LSG_P4 R4/2/2012 QCopyright 2012 Liberty Pumps Inc. All rights reserved Specifications subject to change without notice. Pumps 2448LSG/LSGX - Series Electrical data FULL LOCKED THERMAL STATOR CORD MODEL P VOLTAGE PHASE SF LOAD ROTOR OVERLOA WINDING LENGTH' DISCHARGE AUTOMATIC AMPS AMPS D TEMP CLASS FT 2448LSG202 2 208/230 1 1.0 15 53 135'C B 25 1-1/4"NPT YES 2448LSGX202 2 208-230 1 1.0 15 53 135'C B 25 1-1/4"NPT YES 2448LSG/LSGX- Series Technical Data WOUND FIBERGLASS WITH ANTI FLOATATION FLANGE FIBERGLASS COVER STANDARD, TANK STEEL COVER OPTIONAL 93 GALLON TOTAL BASIN VOLUME CAPACITY PUMP CYCLE=13.5 GALLONS STANDARD-SCHEDULE 40 GALVANIZED GUIDE RAIL OPTIONAL SCHEDULE 40 STAINLESS STEEL GUIDE RAIL BASE% DISCONNECT (GR20) CAST IRON INLET HUB 4"WITH FLANGE GASKET AND PIPE SEAL DISCHARGE PIPING SCHEDULE 80 PVC NEMA 4X OUTDOOR WITH 6-20R 230V JUNCTION BOX RECEPTICLE NEMA 4X OUTDOOR ALARM WITH VISUAL AND ALARM AUDIBLE 80 DBI ALARM IMPELLER 300 SERIES S.S. PAINT POWDERCOATING MAX LIQUID TEMP 140'F/60'C MAX STATOR.TEMP 275'F/135'C THERMAL OVERLOAD 275'F/135'C POWER CORD TYPE SJOOW MOTOR HOUSING CLASS 25 CAST IRON VOLUTE CLASS 25 CAST IRON SHAFT 300 SERIES S.S. HARDWARE STAINLESS ORINGS BUNA N MECHANICAL SEAL UNITIZED SILICON CARBIDE MIN BEARING LIFE 50,000 HRS 2448LSG P5 R4/2/2012 CCopyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. . Pumps 2"BLSG/LSGX - Series Specifications 1.01 GENERAL: The contractor shall provide labor,material,equipment,and incidentals required to provide(QTY)centrifugal grinder pumps as specified herein.The pump models covered in this specification are Series LSG/LSGX200 single phase grinder pumps.The pump furnished for this application shall be model as manufactured by Liberty pumps. 2.01 OPERATING CONDITIONS: Each submersible pump shall be rated at 2 hp volts phase 60 Hz.3450 RPM.The unit shall produce G.P.M.at feet of total dynamic head. The submersible pump shall be capable of handling residential and commercial sewage and grinding it to a fine slurry enabling it to be pumped over long distances in pipelines as small as 1.25"in diameter. The LSG series single stage submersible pump shall have a shut-off head of 110 feet and a maximum flow of 50 GPM @ 10 feet of total dynamic head. The LSGX series two stage submersible pump shall have a shut-off head of 185 feet and a maximum flow of 38 GPM @ 10 feet of total dynamic head. The pump shall be controlled with: A piggy back style on/off float switch(Single Phase Only). 3.01 CONSTRUCTION: 00- Each centrifugal grinder pump shall be equal to the us certified Series LSG/LSGX Grinder pumps as manufactured by Liberty Pumps,Bergen NY.The castings shall be constructed of class 25 cast iron.The motor housing shall be oil filled to dissipate heat.Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N o-ring.All fasteners exposed to the liquid shall be stainless steel.The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord.The motor shall be protected on the lower side with a dual seal arrangement.The first seal is a double lip seal molded in FKM fluoroelastomer or Buna N. The second/main seal shall be a unitized hard face silicon carbide seal with stainless steel housings and spring. The upper and lower bearing shall be capable of handling all radial thrust loads.The lower bearing shall have the additional ability to handle the downward axial thrust produced by the impeller and cutters by design of angular contact roller races.The pump housing shall be of the concentric design thereby equalizing the pressure forces inside the housing which will extend the service life of the seals and bearings.Additionally there shall be no cutwater in the housing volute in order to discourage the entrapment of flowing debris.The pump shall be furnished with stainless steel handle having a nitrile grip. 4.01 ELECTRICAL POWER CORD The submersible pump shall be supplied with 25 feet of multiconductor power cord.It shall be cord type SJOOW(1-phase),capable of continued exposure to the pumped liquid.The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly,with molded pins to conduct electricity.This will eliminate the ability of water to enter internally through the cord,by means of a damaged or wicking cord. 2448LSG P6 R412@012 CCopyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 5.01 MOTORS Single phase motors shall be oil filled,capacitor start/capacitor run,class B insulated NEMA B design,rated for continuous duty. At maximum load the winding temperature shall not exceed 135 degrees C unsubmerged.Since air filled motors are not capable of dissipating heat they shall not be considered equal.The pump motor shall have an integral thermal overload switch in the windings for protecting the motor.The capacitor circuit shall be mounted internally in the pump.Single phase motors shall have an integral solid state starting circuit switch for switching the start winding off. 6.01 BEARINGS AND SHAFT An upper radial and lower thrust bearing shall be required.The upper bearing shall be a single ball/race type bearing.The lower bearing shall be an angular contact heavy duty ball/race type bearing,designed to handle axial grinder pump thrust loads.Both bearings shall be permanently lubricated by the oil,which fills the motor housing.The bearing system shall be designed to enable proper cutter alignment from shut off head to maximum load at 10'of TDH.The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.670". 7.01 SEALS The pump shall have a dual seal arrangement consisting of a lower and upper seal to protect the motor from the pumping liquid.The lower seal shall. be a FKM fluoroelastomer OR Puna N molded double lip seal,designed to exclude foreign material away from the main upper seal.The upper seal shall be a unitized silicon carbide hard face seal with stainless steel housings and spring equal to Crane Type T-6a.The motor plate/housing interface.shall be sealed with a Buna-N o-ring. 8.01 IMPELLER The impeller shall be a investment cast stainless steel impeller,with pump out vanes on the back shroud to keep debris away from the seal area.It shall be keyed and bolted to the motor shaft. 9.01 CUTTER MECHANISM The cutter and plate shall consist of 440 stainless steel with a Rockwell C hardness of 55-60.The stationary cutter plate shall have specially designed orifices through it,which enable the slurry to flow through the pump housing at an equalized pressure and velocity.The stationary cutter shall consist of V shapes to maximize cutting action and arc shape exclusion slots to outwardly eject debris from under the rotary cutter.The rotary cutter shall have(4)blades and be designed with a recessed area behind the cutting edge to prevent the accumulation and binding of any material between rotary cutter and the stationary cutter.The cutting system must incorporate close tolerances for optimum performance. Ring or radial cutters,or those that grind on the outside circumference of shall not be considered equal. 10.01 CONTROLS All single phase units can be supplied with CSA and UL approved automatic wide angle tilt float switches.The switches shall be equipped with piggy back style plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. Manual Pumps are operable by means of a pump control panel. 11.01 PAINT The exterior of the casting shall be protected with Powder Coat paint. 12.01 SUPPORT The pump shall have cast iron support legs,enabling it to be a free standing unit.The legs will be high enough to allow solids and long stringy debris to enter the cutter assembly. 2448LSG_P7 R4/2/2012 CCopyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. Pumps 13.01 SERVICEABILTY Components required for the repair of the pump shall be shipped within a period of 24 hours. 14.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile grommets.The Discharge piping shall be schedule 80 PVC and furnished with a check valve and PVC shut-off ball valve.The tank shall be wound fiberglass or roto-molded plastic.An inlet hub shall be provided with the fiberglass systems. Stainless steel Guide Rail Zinc plated steel Guide Rail "diameter of basin size "height of basin size "distance from top of tank to discharge pipe outlet Fiberglass cover Structural foam polymer cover Steel cover Simplex System with Outdoor panel and alarm Duplex System with Outdoor panel and alarm Separate Outdoor Alarm Remote Outdoor Alarm 15.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity,moisture content and insulation defects.The motor and volute housing shall be pressurized,and an air leak decay test is performed to ensure integrity of the motor housing.The pump shall.be run,voltage current monitored,and the tester checks for noise or other malfunction. 16.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified Facility. 17.01 WARRANTY Standard limited warranty shall be 3 years. 2448LSG_P8 R4/212012 ®Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. www_