2139 SEMINOLE RD - PERMIT PLRS18-0131 .Y j y�j1j
CITY OF ATLANTIC BEACH
? 800 SEMINOLE ROAD
_ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
PLUMBING RESIDENTIAL -
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: PLRS18-0131
Description: abandon septic& install grinder pump into existing sewer
Estimated Value: 2150
Issue Date: 5/21/2018
Expiration Date: 11/17/2018
PROPERTY ADDRESS:
Address: 2139 SEMINOLE RD
RE Number: 169515 0500
PROPERTY OWNER:
Name: Camille Adams
Address: 2139 SEMINOLE RD
ATLANTIC BEACH, FL 32233-5921
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
Phone:
Name: Clay County Master Plumbing LLC
Address: 449 Arthur Moore Dr
GREEN COVE SPRINGS, FL 32043
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE"RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions
applicable to this property that may be found in the public records of this county, and there may
be additional permits required from other governmental entities such as water management
districts, state agencies, or federal agencies.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
PLUMBING PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845 Pl�(L-,S 18 Qj
JOB ADDRESS: ` 1 PERNUT#
NEW OR REPLACEMENT INSTALLATION: Project Value$ ca
TYPE of FIXTURE QTY TYPE of FIXTURE QTY
Bathtub Septic Tank&Pit
Clothes Washer Shower
Dishwasher Shower Pan
Drinking Fountain Slop Sink
Floor Drain Three Compartment Sink
Floor Sink Toilet
Hose Bibs Urinal
Kitchen Sink Vacuum Breakers
Laundry Tray Water Connected Appliances
Lavatory Water Heater
Other Fixtures Water Treating System
RE-PIPE:
TYPE of FIXTURE QTY TYPE of FIXTURE QTY
Bathtub Septic Tank&Pit
Clothes Washer Shower
Dishwasher Shower Pan
Drinking Fountain Slop Sink
Floor Drain Three Compartment Sink
Floor Sink Toilet
Hose Bibs Urinal
Kitchen Sink Vacuum Breakers
Laundry Tray Water Connected Appliances
Lavatory Water Heater
Other Fixtures Water Treating System
MISCELLANEOUS:
❑ Sewer Replacement ❑Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans)
❑ Lawn Sprinkler System-Number of Heads ❑ Well
** VRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection."
Other A/�A/rlDo/t/ s��fiic ��ls ,/ Gie�%yae� I°��nso iiy�ci `xi S�'i`/✓���%/eP
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violMe—
e provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name QQ-PA 1 0, M Phone Number �D — 1 J0
n om — U
Plumbing Company C� COU Mas-�--�e K Office Phone
Co. Address: 'IDlg Cin ar(-c 5 l lRC ��- City �� <e -Zip 3
License Holder(Print): �1C�� �5 e Certification/Registration#
Notarized Signature of License Holder
7JENNIFERSw nd subscribed before me th sday of L 20
JOHNSTONMY COMMISSION#GG 042984
EXPIRES:Octobet27,2o2u Signature of Notary Public
••o Bonded7hruNotaryPublicUndervxiters ,
PERMIT #::16-SJ-18.48710
STATE OF FLORIDA
APPLICATION #:AP 1345573
DEPARTMENT OF HEALTH DATE PAID:
" ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID:
SYSTEM
{y . RECEIPT #:
DOCUMENT #:-PRI 117777 .
CONSTRUCTION PERMIT FOR:: OSTDS Abandonment.
APPLICANT: Camille Adams.
PROPERTY ADDRESS: 2139 Seminole Rd Atlantic Beach,FL 32233
LOT: 1 BLOCK:. SUBDIVISION:
PROPERTY ID #: 169515-0500 [SECTION, TOWNSHIP, RANGE, PARCEL. NUMBER]
[OR TAX ID NUMBER]'. . .
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH ..SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S:, AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF, SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS-,
WHICH: SERVED AS A BASIS FOR ' ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY. RESULT IN THIS PERMIT BEING MADE NULL AND VOID:
ISSUANCE OF, THIS PERMIT DOES NOT EXEMPT THE. APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN. AND SPECIFICATIONS
T L ] GALLONS / GPD CAPACITY
A -I ] GALLONS / GPD CAPACITY
GALLONS. GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K I I GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ]
D [ ] SQUARE FEET. SYSTEM
R [. I SQUARE FEET SYSTEM
A TYPE SYSTEM: [ ] .STANDARD [ ] FILLED ( ] MOUND [ ]
I' CONFIGURATION:. [ ] TRENCH [ ] BED [ ]
N
F LOCATION OF BENCHMARK:
I ELEVATION OF-PROPOSED SYSTEM .SITE [ ] [ / ] [ABOVE/BELOW IBEN CHMARK/REFERENCE POINT
E BOTTOM .OF DRAINFIELD TO BE ] LABOVE/BELOW]'BENCHMARK/REFERENCE POINT
L
D FILL REQUIRED- [ 0.00.] INCHES. EXCAVATION.REQUIRED: [ ] INCHES
Have the:tank abandoned in accordance with the following procedures:.(a)The tank shall be pumped out:(b)The bottom of
o.: the.tank shall be opened or ruptured,.orthe entire tank collapsed so as to prevent the tank from retaining water;and(c)The
T_ tank shall be filled with clean sand or other suitable:material,and completely covered with soil'.Have the system inspected
H :by the health department after it has been pumped and ruptured but before it is filled with sandand covered.
E
R
SPECIFICATIONS BY: John G' CCorr�dy ,{ TITLE' Environmental Specialist LI
APPROVED BY: TITLE: Environmental Specialist II Duval CHD
John'G Cordy
DATE, ISSUED: 05/18/20,18.. -. EXPIRATIONDATE 08/16/2018
DH 4016, 08/09 (Obsoletes all previous editions wfiich may not be used)
Incorporated: 64E-6.003, FAC: Page 1 of 3
v 1.1.4 AP1345573 SE-1
omnVoreo
den
Pump Specifications
2448LSG, 2448LSGX Series Omnivore
2HP Simplex Grinder Packages
11131pol ;;G.'
N' � 1j
��11■III�C�
11�
2448LSG/LSGX - Series Dimensional Data
0 30 3/16"
[77cm]
FIBERGLASS OR STEEL COVER
� � �� (FIBERGLASS SHOWN)
-a �
° DISCHARGE
PIPE
0
32.9in JB230
[84cm] JUNCTION BOX
WITH
6-20P 230 VOLT
RECEPTACLE
12 •
n
18.Oin [30cm] 4.1 in
[46cm] _ [10cm]
ALM-2W
OUTDOOR
4" FIBERGLASSWATER
INLET HUB AND 48" ALARM
FERNCO SEAL [122cm] 115 VOLT
5.9in
[15cm]
ANTI FLOATATION COLLAR
�24
61 cm
[ ] �o
INSIDE DIAMETER ❑
03011
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED RN THIS [76 c m]
DRAWING IS THE SOLE PROPERTY OF 2448 SERIES DIMENSIONAL
LIBERTY PUMPS.ANY REPRODUCTION DWG.NO.
IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF LIBERTY PUMPS 3¢e DATE: 2/16/12 R�
IS PROHIBITED. PIA A
APPLICATION DO NOT SCALE DRAWING SCA- LB SHEET I of 7
2448LSG_P2 R4/2/2012 ®Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
PII PS.
0 4„
[61 cm]
TANK
0„
[76cm]
ANTI-FLOAT
ELECTRICAL CONDUIT
COUPLING 2" NPT
101, 12"
[25cm] [30cm]
18.Oin ® ® -
[46cm]
GR20 GUIDE RAIL
DISCONNECTED VIEW
SEE DETAIL NEXT PAGE
r,— Ll
2 „
[53cm]
1 ALARM
[33cm] FLOAT
OFF FLOAT
d
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF 2448 SERIES DIMENSIONAL
LIBERTY PUMPS.ANY REPRODUCTION DWG.NO.
IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF LIBERTY PUMPS ScE DATE: 2/16/12 RE.
IS PROHIBITED. A A
APPLICATION DO NOT SCALE DRAWING SCALE:IA SHEET2OF3
2448LSG P3 R4/2/2012 ®Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
P>tnnps�
3.6in
[9cm]
if
6 5/8" 5.2in
[17cm] [ 13cm]
17.Oin
[43cm]
UPPER PIPE.
GUIDE BRACKET
20.7in
[53cm]
5.2in
V�
[13cm]
9.Oin
[23cM]
1011
[25cm] 19.5in
.[50cm] ° o
GR20 GUIDE RAIL BASE
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE PROPERTYOF
LIBERTY PUMPS.ANY REPRODUCTION DWG.NO. 244 8 SERIES
EOICS DIVCNSIONAL
IN
PART OR AS A WHOLE WITHOUT THE
6
WRITTEN
ITED�ION OF LIBERTY PUMPS Stw DATE 2/27/12 Rte.
M A
APPLICATION DO NOT SCALE DRAWING "SCALE:1d SHEET I of I
2448LSG_P4 R4/2/2012 QCopyright 2012 Liberty Pumps Inc. All rights reserved Specifications subject to change without notice.
Pumps
2448LSG/LSGX - Series Electrical data
FULL LOCKED THERMAL STATOR CORD
MODEL P VOLTAGE PHASE SF LOAD ROTOR OVERLOA WINDING LENGTH' DISCHARGE AUTOMATIC
AMPS AMPS D TEMP CLASS FT
2448LSG202 2 208/230 1 1.0 15 53 135'C B 25 1-1/4"NPT YES
2448LSGX202 2 208-230 1 1.0 15 53 135'C B 25 1-1/4"NPT YES
2448LSG/LSGX- Series Technical Data
WOUND FIBERGLASS
WITH ANTI FLOATATION FLANGE
FIBERGLASS COVER STANDARD,
TANK STEEL COVER OPTIONAL
93 GALLON TOTAL BASIN VOLUME
CAPACITY PUMP CYCLE=13.5 GALLONS
STANDARD-SCHEDULE 40 GALVANIZED
GUIDE RAIL OPTIONAL SCHEDULE 40 STAINLESS STEEL
GUIDE RAIL BASE%
DISCONNECT (GR20) CAST IRON
INLET HUB 4"WITH FLANGE GASKET AND PIPE SEAL
DISCHARGE PIPING SCHEDULE 80 PVC
NEMA 4X OUTDOOR WITH 6-20R 230V
JUNCTION BOX RECEPTICLE
NEMA 4X OUTDOOR ALARM WITH VISUAL AND
ALARM AUDIBLE 80 DBI ALARM
IMPELLER 300 SERIES S.S.
PAINT POWDERCOATING
MAX LIQUID TEMP 140'F/60'C
MAX STATOR.TEMP 275'F/135'C
THERMAL OVERLOAD 275'F/135'C
POWER CORD TYPE SJOOW
MOTOR HOUSING CLASS 25 CAST IRON
VOLUTE CLASS 25 CAST IRON
SHAFT 300 SERIES S.S.
HARDWARE STAINLESS
ORINGS BUNA N
MECHANICAL SEAL UNITIZED SILICON CARBIDE
MIN BEARING LIFE 50,000 HRS
2448LSG P5 R4/2/2012 CCopyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
. Pumps
2"BLSG/LSGX - Series Specifications
1.01 GENERAL:
The contractor shall provide labor,material,equipment,and incidentals required to provide(QTY)centrifugal grinder pumps as specified
herein.The pump models covered in this specification are Series LSG/LSGX200 single phase grinder pumps.The pump furnished for this
application shall be model as manufactured by Liberty pumps.
2.01 OPERATING CONDITIONS:
Each submersible pump shall be rated at 2 hp volts phase 60 Hz.3450 RPM.The unit shall produce G.P.M.at feet
of total dynamic head.
The submersible pump shall be capable of handling residential and commercial sewage and grinding it to a fine slurry enabling it to be pumped over
long distances in pipelines as small as 1.25"in diameter. The LSG series single stage submersible pump shall have a shut-off head of 110 feet and
a maximum flow of 50 GPM @ 10 feet of total dynamic head. The LSGX series two stage submersible pump shall have a shut-off head of 185 feet
and a maximum flow of 38 GPM @ 10 feet of total dynamic head.
The pump shall be controlled with:
A piggy back style on/off float switch(Single Phase Only).
3.01 CONSTRUCTION: 00-
Each centrifugal grinder pump shall be equal to the us certified Series LSG/LSGX Grinder pumps as manufactured by Liberty Pumps,Bergen
NY.The castings shall be constructed of class 25 cast iron.The motor housing shall be oil filled to dissipate heat.Air filled motors shall not be
considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N o-ring.All
fasteners exposed to the liquid shall be stainless steel.The motor shall be protected on the top side with sealed cord entry plate with molded pins to
conduct electricity eliminating the ability of water to enter internally through the cord.The motor shall be protected on the lower side with a dual seal
arrangement.The first seal is a double lip seal molded in FKM fluoroelastomer or Buna N.
The second/main seal shall be a unitized hard face silicon carbide seal with stainless steel housings and spring.
The upper and lower bearing shall be capable of handling all radial thrust loads.The lower bearing shall have the additional ability to handle the
downward axial thrust produced by the impeller and cutters by design of angular contact roller races.The pump housing shall be of the concentric
design thereby equalizing the pressure forces inside the housing which will extend the service life of the seals and bearings.Additionally there shall
be no cutwater in the housing volute in order to discourage the entrapment of flowing debris.The pump shall be furnished with stainless steel handle
having a nitrile grip.
4.01 ELECTRICAL POWER CORD
The submersible pump shall be supplied with 25 feet of multiconductor power cord.It shall be cord type SJOOW(1-phase),capable of continued
exposure to the pumped liquid.The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code.
The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord
plate assembly,with molded pins to conduct electricity.This will eliminate the ability of water to enter internally through the cord,by means of a
damaged or wicking cord.
2448LSG P6 R412@012 CCopyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
5.01 MOTORS
Single phase motors shall be oil filled,capacitor start/capacitor run,class B insulated NEMA B design,rated for continuous duty. At maximum load
the winding temperature shall not exceed 135 degrees C unsubmerged.Since air filled motors are not capable of dissipating heat they shall not be
considered equal.The pump motor shall have an integral thermal overload switch in the windings for protecting the motor.The capacitor circuit shall
be mounted internally in the pump.Single phase motors shall have an integral solid state starting circuit switch for switching the start winding off.
6.01 BEARINGS AND SHAFT
An upper radial and lower thrust bearing shall be required.The upper bearing shall be a single ball/race type bearing.The lower bearing shall be
an angular contact heavy duty ball/race type bearing,designed to handle axial grinder pump thrust loads.Both bearings shall be permanently
lubricated by the oil,which fills the motor housing.The bearing system shall be designed to enable proper cutter alignment from shut off head to
maximum load at 10'of TDH.The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.670".
7.01 SEALS
The pump shall have a dual seal arrangement consisting of a lower and upper seal to protect the motor from the pumping liquid.The lower seal shall.
be a FKM fluoroelastomer OR Puna N molded double lip seal,designed to exclude foreign material away from the main upper seal.The upper seal
shall be a unitized silicon carbide hard face seal with stainless steel housings and spring equal to Crane Type T-6a.The motor plate/housing
interface.shall be sealed with a Buna-N o-ring.
8.01 IMPELLER
The impeller shall be a investment cast stainless steel impeller,with pump out vanes on the back shroud to keep debris away from the seal area.It
shall be keyed and bolted to the motor shaft.
9.01 CUTTER MECHANISM
The cutter and plate shall consist of 440 stainless steel with a Rockwell C hardness of 55-60.The stationary cutter plate shall have specially
designed orifices through it,which enable the slurry to flow through the pump housing at an equalized pressure and velocity.The stationary cutter
shall consist of V shapes to maximize cutting action and arc shape exclusion slots to outwardly eject debris from under the rotary cutter.The rotary
cutter shall have(4)blades and be designed with a recessed area behind the cutting edge to prevent the accumulation and binding of any material
between rotary cutter and the stationary cutter.The cutting system must incorporate close tolerances for optimum performance. Ring or radial
cutters,or those that grind on the outside circumference of shall not be considered equal.
10.01 CONTROLS
All single phase units can be supplied with CSA and UL approved automatic wide angle tilt float switches.The switches shall be equipped with piggy
back style plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable.
Manual Pumps are operable by means of a pump control panel.
11.01 PAINT
The exterior of the casting shall be protected with Powder Coat paint.
12.01 SUPPORT
The pump shall have cast iron support legs,enabling it to be a free standing unit.The legs will be high enough to allow solids and long stringy debris
to enter the cutter assembly.
2448LSG_P7 R4/2/2012 CCopyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Pumps
13.01 SERVICEABILTY
Components required for the repair of the pump shall be shipped within a period of 24 hours.
14.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE
Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile
grommets.The Discharge piping shall be schedule 80 PVC and furnished with a check valve and PVC shut-off ball valve.The tank shall be wound
fiberglass or roto-molded plastic.An inlet hub shall be provided with the fiberglass systems.
Stainless steel Guide Rail
Zinc plated steel Guide Rail
"diameter of basin size
"height of basin size
"distance from top of tank to discharge pipe outlet
Fiberglass cover
Structural foam polymer cover
Steel cover
Simplex System with Outdoor panel and alarm
Duplex System with Outdoor panel and alarm
Separate Outdoor Alarm
Remote Outdoor Alarm
15.01 TESTING
The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity,moisture content and
insulation defects.The motor and volute housing shall be pressurized,and an air leak decay test is performed to ensure integrity of the motor
housing.The pump shall.be run,voltage current monitored,and the tester checks for noise or other malfunction.
16.01 QUALITY CONTROL
The pump shall be manufactured in an ISO 9001 certified Facility.
17.01 WARRANTY
Standard limited warranty shall be 3 years.