Loading...
410 GARDEN LANE - PERMIT RESA17-0024 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD _ ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247 581.4 RESIDENTIAL ADDITION - SINGLE OR TWO FAMILY RESIDENTIAL ADDITION MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RESA17-0024 Description: residential addition &deck Estimated Value: 70000 Issue Date: 2/6/2018 Expiration Date: 8/5/2018 PROPERTY ADDRESS: Address: 410 GARDEN LN RE Number: 172020 5208 PROPERTY OWNER: Name: TOOMER CURTIS W Address: 410 GARDEN LN ATLANTIC BEACH, FL 32233-4528 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: ELITE CUSTOM HOMES & RENOVATIONS INC Address: 2304 Peach DR . JACKSONVILLE, FL 32246 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. City of Atlantic Beach APPLICATION NUMBER Building Department (To ki6.assigned by the Bwlding Department j 800 Seminole Road c C I Atlantic Beach, Florida 32233-5445 ` , _ : rr N Phone(904)247-5826 • Fax(904)247-5845 II I E-mail: building-dept@coab.us Date routed'- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 'J� C) UL(IL De __ ept review required Yes No B:uildin Applicant: L -CUL ro (1i1,� -Planning &Zoning 1 Tre oris rator Project: �. CLS t 40-�a \ dk�31) p Public Utilities Public Safety Fire Services ,Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: a APPLICATION STATUS Reviewing Department First Review: ❑Approved. [Denied. ❑Not applicable (Circle one.) Comments: cl--U- I a`j PLANNING &ZONING I Reviewed by: Date: TREE ADMIN. Second Review: Approved as revised. Denied. pp ❑ ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: /-9-C;?0�� FIRE SERVICES Third Review: ❑Approved as revised. []Denied. []Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 CITY OF ATLANTIC BEACH r 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 O F F I C E COPY (904) 247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 12.11.2017 Permit#: RESA17-0024 Applicant: Elite Custom Homes & Site Address: 410 Garden Lane Renovations,Inc. Review: 1 Site Address: RE#: Phone: 253.4130, 686.4818 Email: Jkconstruction64 ahoo.com Homeowner: Michele Toomer, 343.8621 CORRECTION COMMENTS: These are review comments.from 1 of 4 departments reviewing this permit application. �m the 2014 5" Edition of the FBC-Existing Building Code, choose a method of construction compliance/alteration level. Chapter 3, Section 301, Compliance Methods. Chapter 7, Alterations. Place this information on Pa C-1, under Building Code summary. 2 Pages please. Mike Jones Building Inspector/Plan Reviewer Q City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 Fax (904) 247-5845 rn<a i l p c/ P1 a k 12P v,-e o ri rvr.e-n 13 1 CITY OF ATLANTIC BEACH sx, 800 Seminole Road j O F F I E O Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date V Revision to Issued Permit Corrections to Comments_ Permit# '6 f1 To o z Project Address WD 6z"Z 8e A [�� \kt Contractor/Contact Name A, Phone `7`d Email JtlD rJ'6 T Iq 7yu(1 b y (c dv Description of Proposed Revision/Corrections: Permit Fee Du $ s O.O O e�- a�' SGP k> ���- cr uj- RIA u �e N(00cz Additional Increase in Building Value $ Additional S.F. By signing below,I a"t°nyj 1 � //9 affirm the Revision is inclusive of the proposed changes. ,-;�Irrinted me) Signa ref Contractor/Agent(Contracto st sign if increase in valuation) Date Li (Office Use Only) Approved _ Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: Buil `fel �PJannina &Zoning Reviewed By Tree Administrator u i1AFer� Public Safety Date Fire Services OF ATLANTIC BEACH JA N 2 5 2018 I 800 Seminole Road Atlantic Beach Florida 32233 REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COMMENTS Date Revision to Issued Permit Corrections to CommentsPermit# &S)i`7 x002 It Project Address 4l0 /Aeo- Contractor/Contact Name jEM&, 6V6 4o, Phone Email ,� G d� �` �j� aw t !h CDa"- Description of Proposed Revision/Corrections: Permit Fee Du $ �v.D� 6 /d -� 4��` � c4 civ Additional Increase in Building Value $ Additional S.F. By signing below,I a I affirm the Revision is inclusive of the proposed changes. inted na na re of Contractor/Agent(Contractor m n if increase in valuation) Date (Office Use Only) Approved_ Denied Not Applicable to Department 99 / , Revision/Plan Review Comments 6 ri a c 4 l p,zk- —� ,,O 6 Lo py I �7 Department Review Required: Ag Buildin - l/ Planning &Zoriin Reviewed By Tr dministrator rks Public i sties Public Safety Date Fire Services City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road r Atiantic Beach, Florida 32233-5445 4: .. Phone(904)247-5826 • Fax(904)247-5845 _ • A;y, E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l l_I(Vckul t LUL Departn3ent review required Yes No Buildin I`Pli�nin" 8�Zonin Applicant: t1� t A tU- brro k�f� 9... 9 �"Tre" - rms gator Project: q P Public Utilities Public Safety Fire Services Review fee $ " Dept Signature- Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. PrDenied. ❑Not applicable (Circle one.) Comments: BUILDING �1 SPL-ANNING &'ZONING -F ( ,l Reviewed by�'-!"����� Date: "�— f TREE ADMIN. Second Review: [-]Approved as revised. Denied. []Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by'�_� Date: I—( Cl—1 FIRE SERVICES Third Review: []Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ' Jr, ZONING REVIEW COMMENTS SJ City of Atlantic Beach Community Development Department J yr 800 Seminole Road Atlantic Beach,Florida 32233-5445 Date: 12/14/2017 OFFICE COPY Permit: RESA17-0024 Applicant: Elite Custom Homes Review: ZONING Address: 2304 Peach Drive, Jacksonville FL Site Address: 410 GARDEN IN Phone: 904-233-4130 RE#: 172020 5208 Email: Jkconstruction64@yahoo.com Correction Comments 1. Setbacks: Please provide the side and rear setbacks for the proposed addition and deck. The Selva Marina Garden PUD requires a 10' setback for the northern side lot line and a 20' rear setback. 2. Pool: Please provide the rear setbacks for the proposed pool. The Selva Marina Garden PUD requires a 5' side and rear setback for pools. 3. Cabana: The Selva Marina Garden PUD does not allow detached structures outside of the "dwelling zone". The dwelling zone is defined as the area within the required setbacks for the house. As a result, any detached structure is required to be setback at least 20' from the rear lot line. 4. Windows/Openings:The Selva Marina Garden PUD states that any portion of the side wall within 10' of the side lot line shall contain no windows or openings. The proposed addition appears,to violate this requirement. Please show that this requirement is being met or revise plans accordingly. Informational Comments Brian Broedell Planner CITY OF ATLANTIC BEACH 800 Seminole Road ! Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date Revision to Issued Permit Corrections to Comments Permit# Project Address WD 6i ' t Contractor/Contact Name Phone vCJ`b� `bI Email J Ke*Dov) T-k UG f ) d7 )b v Y�/(D� l Description of Proposed Revision/Corrections: Permit Fee Due$ Re C C- 'Additional Increase.in Building Value $ Additional S.F. By signing below,I a�` YJ / ev affirm the Revision is inclusive of the proposed changes. Signa reqftontractor/gent(Contracto st sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments 'iZe-dr" De a1 nt Review Required: `�G Buil ' i%Z-ob Plann & nirr � Reviewed By Tree Administrator P'u iG�IFe Public Safety Date Fire Services / V. I t CITY OF ATLANTIC BEACH JAN 2 5 2018 11 f 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date 0'��'d Revision to Issued Permit Corrections to Comments Permit# Project Address 41/0 Contractor/Contact Name '611)e �U6 0q--I' J:�L cs4" Phone_�C —6"f1b qL Email Description of Proposed Revision/Corrections: Permit Fee Due$ Additional Increase in Building Value $ Additional S.F. By signing below,I . Q�(11`, ICA-- affirm the Revision is inclusive of the proposed changes. inted n na re of Contractor gent(Contractor in n if increase in valuation) Date (Office Use Only) Approved / Denied Not Applicable to Department Revision/Plan Review Comments De artment Review Required: Buildin Le Planni ng &Zonin Reviewed By Tr dministrator " c,v orks J Public ti ities Public Safety Date Fire Services %W1,.�,Y City of Atlantic Beach =� _ APPLICATION NUMBER a Building Department _ (To be assigned by the Building Department.) 800 Seminole Road -, -.— Atlantic Beach, Florida 32233-5445 - ; 1 Phone(904)247-5826 • Fax(904)247-58 5 �, 2® i I Lrcilj; i� E-mail: building-dept@coab.us 17 Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 (� l�"1(/�r� �vi,tll'� Depadment review required Yes No Buildin ' Applicant: EULA L .CULbro �(b nu, Planning &Zoning pp i Tre minis r_ator Project: f LS`t Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By , Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. [2/Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b , ate: TREE ADMIN. Second Review: Approved as revised. ❑Denied. ❑Not applicable PlJ E WORKS ,�" Comments: r I hPUBLIC UTILITIES SWVJ� WAY "h0 (aYgv� Lqs�-EG�►� PUBLIC SAFETY Reviewed by: Date: /'' " FIRE SERVICES Third Review: []Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 - '_. '• ,1�� CITY OF ATLANTIC BEACH DEPARTMENTOF PUBLIC WORKS P ;'. 1200 Sandpiper Lane Atlantic Beach.FL 32233-43 IN TELEPHONE:(904)247-5534 FAX:(1)041247-5843 wwwxoah.us OFFICE COPY CONTRAC'T'OR: DATE: 12-12-17 Elite Custom I IamcS<< RCn0Vati0nS. Inc. PERMIT# RESA17-0024 2304 Peach Drive ADDRESS: 410 Garden Lane Jacksonville. PL 32246 Atlantic Beach, FI, 32233 Email: Ac nstrLIC010t164W vahtm.Cont PERMIT APPLICA'T'ION FOR NEW ADDITION AND DECK Your permit application has been denied by the Public Works Department for the reasons listed below. Please SUbmit this Inlormation at YOUr earliest convenience in order for uS to approve your application. Il'you have any questions, please contact Scott WilliamS, Public Works Director at 904-247-5534 or email swilliamslmcoab.us. PUBLIC WORKS CORRECTION ITEMS: (.Sttbtttit tltefollml,inl;inforntatiou to the Public JVorks Department) e Provide impervious surface calculations for entire lot (existing and post construction). • Section 24-66(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 400 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-66(b). o Provide a detailed plan of water retention area and how water runoff gets to water retention areas and then to street. © Provide a detailed plan of deck being built, showing potential pool with measurements. PUBLIC WORKS CONDITIONS OI' APPROVAL: (The following comments will be printer!on J otw permit as Conditions o f'Approval) • Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (247-5814) to request an inspection from Public Works for Erosion and Sediment Control Inspection prior to start of construction. © All runoff must remain on-site during construction. o If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. • Roll off container company must be on City approved list (Advanced Disposal, Realco Recycling, Shapell's Inc., Republic Services, Donovan Dumpsters). Container cannot be placed on City right-of-way. o Full right-of-way restoration,.including sod, is required. • Must provide a topographic (TOPO) survey with water retention for final C.O. Inspection. o All old decking must be removed from job site by Contractor. cc: Toni Gindlespergcr, Building Department .Ienniler.lahnston, Building Department ti DIN CITY OF ATLANTIC BEACH 800 Seminole Road JAN 08 2010 ° Atlantic Beach,Florida 32233 e. REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS DateRevision to Issued Permit Corrections to Comments Permit# Project Address l n___ 67C sE 6-1&--- ®J~ V Contractor/Contact Name— Phoney V CJ i7� `b 7� Email GD i�`� r�.V G J 1V0 �/ h 0t7 Description of Proposed Revision/)Corrections:,1 ( Permit Fee Due$ Additional Increase in Building Value $ Additional S.F. By signing below,I a e� � affirm the Revision is inclusive of the proposed changes. r rinted ame) SignaxUre'grcontractor/Agent(Contracto st sign if increase in valuation) Date �Zr t/ (Office Use Only) Approved Jz Denied Not Applicable to Department Revision/Plan Review Comments De artment Review Required: f Buil �Plannina &Zoning eviewe y Tree Administrator Public Safety Date Fire Services V j, CITY OF ATLANTIC BEACH JAN 2 5 2018 Hl 800 Seminole Road Atlantic Beach,Florida 32233 Q A . EF V, JAN 26 2018 REVISION REQUEST CORRECTIONS TO PLAN REVIEW MMENTS J -------------- Date Revision to Issued Permit Corrections to Comments Permit Project Address 41/0 Contractor/Contact Name jcli)e 6V640V't -4 Phone lx- Email —)K 6outsJt0eA'r-N 61 h6o. cow- Description of Proposed Revision Corrections: Permit Fee Due$ 6 Additional Increase in Building Value $ Additional S.F. By signing below,I K&I ly-( affirm the Revision is inclusive of the proposed changes. (printed na na re of Contractor/Agent(Contractor rn h if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments D !?_!rtment Revieww Required; 3L-dn V;7 eie iewed y Tr dministrator .-Wo-irks l 7 Public tiities-'-' Public Safety Ole Date Fire Services City of Atlantic Beach APPLICATION NUMBER Building Department ~- --, _ _ (To be assigned by the Building Department.) S 800 Seminole Road (( 1 n Atlantic Beach, Florida 32233-5445 . �-,l •� Phone(904)247-5826 • Fax(904)247-58Q5°� 07 2017I iWj,1 E-mail: building-dept@coab.us I' Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l (� ��CNC� I Ui�(1 Department review required Yes No Buildin Applicant: L -CELS-brin kkA6 Planning &Zoning Tre anis rator Project: f � ��.i�,�� 4- P FIN.blic•Ufiliti.es Public Safety Fire Services iRe�iew fee $ � �Dep_t_Signatu_re ����- � � Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. H-Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: 121F/l 7 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. []Not applicable I WORK, Co ments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. [—]Denied. El Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 CITY OF ATLANTIC BEACH i 800 Seminole Road Atlantic Beach,Florida 32233 JAN 0 8 2010 "tiL?si1"J'" t; REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date Revision to Issued Permit Corrections to Comments_ Permit# Project Address Wc) (S i kv� Contractor/Contact Name c �°J /`+` I'l t✓' / l `� Phone y 1 �CJ`i7� �j Email e Oo Description of Proposed Revision/Corrections: Permit Fee Due$ ek Ci t2 �a-n-C' a,- \uwe' L L Additional Increase in Building Value$ Additional S.F. j/ L By signing below,I � G?`��'� l � �/ affirm the Revision is inclusive of the proposed changes. � rinted ame) Signature oftontractor/Agent(Contracto st sign if increase in valuation) Date L' (Office Use Only) Approved Denied Not Applicable to Department v Revision/Plan Review Comments �a S A)I& tFW De artment Review Required: Buil ' w �Plannina &Zoning Reviewed By Tree Administrator u �y Public Safety Date Fire Services ,f �1._l 1 CITI'OF.ATLANTIC BEACH JAN 2 5 2018 111 S�� 800 Seminole Road Atlantic Beach,Florida 32233 I� 11i1 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW C2018 Date Revision to Issued Permit Corrections to Comments_ Permit# Project Address 4/0 Contractor/Contact Named a 9L° 60640o.", w J c , IDoSr L �li; W)(� �-y/ Plione �y"/ Email _) d- I` 6) Description of Proposed Revision/Corrections: Permit Fee Due $ Additional Increase in Building Value $ Additional S.F. _71- By signing below,I Q�(1�, p C.� affirm the Revision is inclusive of the proposed changes. (printed n na re of Contractor/Agent(Contractor m n if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments ' De artment Review Required: �1 f Buildin Planning &Z—on— in Reviewed By Tr dministrator c. s (, Public 1 i ti ities ;�"• '�� Public Safety ®�� B Date Fire Services LegalBuilding Permit Application, City of Atlantic Beach OFFICE COPY 800 Seminole Road,Atlantic Beach, FL 32233 0EC Phone: (904) 247-5826 Fax: (904) 247-5845 d Job Address: /-//0 eo. oke,Y� Permit Number, ?-t SAI 1-00-a ' Valuation of Work(Replacement Cost)$ ?QiQQQ-1D0 Heated/CooledSF �230 on-Heated/Cooled ° Class ofWork(Circle one): New Alteration Repair W1 Window/Door ° �e��i�n�mp�ed�m�ue�O�e�e)� �mme�a| ' ° Ifanexisting structure, isafire sprinkler system installed?(Circle one): Yes Nn ' * Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Florida Product Approval# for multiple products use product approval form PropertV Owner Information Name: Add city State_ rl�-/ zip Phone E-Mail Owner orAgent(if Agent, Power of Attorney orAgency Letter Required) Contractor Information Address Q/0 A40f_ City Z Office Phone $99- 1,3 0 —Job Site/Contact Number 5"01/- _L/S) /V State Certification/Registration# 60o!�Q440!�;79 E-Mail Jf4�',0j;A 41 9% Architect Name& Phone# Engineer's Name&Phone# Workers Compensation "'""'"'/ =="""','","°^/ Expiration Date App|icahnnishereby made toobtain apermit tocl_o_Je�vorkand installations osindicated. |certify that nowork orinstallation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all app|icab|e./amaregulating construction and zoning. ^� WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY _ RES II sr�,lr TREE & VEGETATION AFFIDAVIT City of Atlantic Beach f` s Department of Community Development Planning&Zoning Division 800 Seminole Road Atlantic Beach,FL 32233 (P)904247-5800 (F)904247-5845 PERMIT# SECTION 1-APPLICANT INFORMATION r./Owner(s) r Legal Authorized Agent* NAME OF APPLICANT �G , l CTA old 0���.(" �cdeE� , NAME OF COMPANY _,F/1 rf (�E�L01lC,�tty�►- .�dr� ADDRESS OF COMPANY Pear,,, Q>Z. :s 4'�'Kz" 16- 1- 6 PHONE 199V-a31-19130 CELL FOY-641-W14 EMAIL CONTRACTOR CERTIFICATION NUMBER G G /a 7 ATLBCH BUSINESS TAX RECEIPT NUMBER Api 3 p SECTION 11-SITE INFORMATION i STREET ADDRESS OF PROPERTY �-n,4ex-, Y% 13 r If an address has not been assigned to this property,contact the AB Building Department at(904)247-5826 to request an address. P, LEGAL DESCRIPTION 3 3 loVir,,oA, 1 i Awv /.VY11 LOT BLOCK SUBDIVISION REAL ESTATE NUMBER LOT OR PARCEL SIZE: SQ FT AC � I RESIDENTIAL COMMERCIAL OTHER(SPECIFY) I 1 affirm that 1 have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation"of the Municipal Code of Ordin ces for the City of Atlantic Beach,FL and/or 1 have participated in a pre-application meeting with the Administrator of those I regu a ions. Subsequ ntly,l a irm that no regulated trees and no regulated vegetation will be damaged,destroyed and/or removed i fro a ove-descr ed or cent pr perti sin conjunction with this project. d SIGNATURE OF OWNEIT SIGNATURE OF OWNER I ��a n �a( Signed and sworn before me on this �� day of ptCQV,.� ����- ,by State of �0f" 0& T&)a M County of Identification verified: I Oath sworn: r Yes r No ii „pYP�., 3t ,ot?:...,�.,,, JENNIFER JOHNSTON MY COMMISSION#GG 042984 Notary SI ture EXPIRES:October 27,2020 Bonded Thru Notary Public Underwriters My Com on expires Raf-4r' . a t COVENANTS AND RESTRICTIONS IIJIS INSTRUMENT PREPA-,ED DY, and GEORGE BULL EASEMENTS FOR ELECTRIC AND j►TLgTLA SELVA CH,F A DRIVE SELVA BEACH,FIA.32233 SANITARY SEWER SERVICE FOR SELVA MARINA GARDEN TWO KNOW ALL MEN BY THESE PRESENTS: That, WHEREAS, Sevilla Development Corporation, Inc. , a Florida cor- poration, hereinafter called "Developer," is now the owner of Selva Marina Garden Two according to plat thereof recorded in Plat Book , page , current public records of Duval County, Florida; and, WHEREAS, said Developer is developing said land known as Selva Marina Garden Two in accordance with Ordinance No. 90, Section 28-17, Planned Unit Development, as amended, of the City of Atlantic Beach, Florida, pursuant to a Public Hearing held on , at the City Hall, Atlantic Beach, and the Developer, with the knowledge and approval of the City, is placing certain covenants and restrictions upon the use of all of the lots to be platted, and is desirous that said covenants and restrictions shall run with the title to the land hereby restricted; and, WHEREAS, the City, to facilitate the implementation of the en- forcement of the covenants and restrictions that are within its legal province to enforce, it being hereby acknowledged that the City's approval of the quality of workmanship and materials is limited to compliance with the Southern Building Code, and that the City will make no judgment as to harmony of exterior design and location with existing structures and re- quirements for ornamental plantings; and that provisions as to location with respect to front, rear and side lot lines, topog- raphy and finish grade elevation and the location of subsidiary structures as herein outlined will be enforced by the City in accordance with the conditions precedent to approval of this P.U.D. and a Special Advisory Planning Board, hereinafter referred to as the "Board," whose functions are as hereinafter set forth: NOW, THEREFORE, for and in consideration of the premises and for other good and valuable considerations, the Developer, for itself and its successors and assigns, does hereby restrict the use, as hereinabove provided, of all of the lots included in said plat of Selva Marina Garden Two, and does hereby place upon said lots the following covenants and restrictions to run with the title to said lots and the grantees of any deed con- veying any lot or lots shown on said plat, or any parts or portions thereof, shall be deemed by acceptance of such deed to have agreed to all such covenants and restrictions, and to have covenanted to observe, comply with and be bound by all such covenants and restrictions, as follows: SECTION I - GENERAL PROVISIONS A. These restrictive covenants shall run with the title to the land in said subdivision owned by the Developer and shall be binding upon the Developer, its successors and assigns, and all persons claiming by, through and under - 1 - 032682 the Developer, and shall remain in full force and effect until January 1, 2000, except as hereinafter provided. After December 31, 1999, these restrictive covenants shall be automatically extended for successive periods of ten (10) years unless an instrument signed by the then owners of a majority of the lots in said subdivision has been duly recorded, agreeing to terminate or change said cove- nants in whole or in part. B. The Developer has given the Jacksonville Electric Authority an easement to construct, operate, lay, improve and/.or re- pair, operate and maintain electric cables and associated equipment along the paths on which said electric cables and associated equipment are to be laid in, on, along, over, through, across or under said Selva Marina Garden Two, for an underground system to provide electric service to the building to be constructed on the lots, and to pro- vice street lighting in said Selva Marina Garden Two. C. No signs of any kind shall be displayed to the public view in said subdivision, except one professional sign of not more than one (1) square foot, one sign of not more than three (3) square feet advertising the property for sale or rent, or signs used by a builder to advertise the property during the construction and sales period, or signs pertain- ing to or advertising said subdivision. D. 1. No noxious or offensive trade, business or occupation shall be carried on in said subdivision, nor shall any- thing be done thereon which shall be or become an annoyance or a nuisance to the neighborhood. Campers, motor-homes, boats/boats on trailers and motor vehi- cles may be parked or kept in said subdivision only provided same does not become unsightly, abandoned or a nuisance to, or in, the neighborhood. 2. Repairs of wheeled vehicles or boats of any kind out- side of an enclosed garage is prohibited. Storage, (storage being defined as parking for periods of long- er than one (1) week) of wheeled vehicles or boats outside of an enclosed garage is prohibited. E. Temporary buildings and sheds used during the construction period of the permanent building may remain only during the required construction period. F. No lot, or lots, in said subdivision shall be resubdivided by any instrument, conveyance or plat unless such resubdi- vision is the act of the Developer, or unless such resub- division is first approved by the Board, except that any lot may be divided between, and become a part of the ad- joining lots on either side or two (2) lots may be con- solidated to make a single building plot. G. 1. No structure or building shall be erected, placed, altered-or permitted in the subdivision until the building plans, specifications and plot plan showing the location of such building have been reviewed by the Special Advisory Planning Board as to quality of workmanship and materials, as to harmony of exterior design and location with existing structures, as to - 2 - 032682 location with respect to front, rear and side lot lines, as to topography and finish grade elevation and as to location of existing trees and plants that may be initially removed or affected by the structure or building, and recommended for approval or disap- proval by the Building Official of the City of Atlantic Beach. 2. In the event the Board, or its designated representa- tive fails to recommend approval or disapproval within thirty (30) days after plans and specifications or other applications have been submitted to it then, in that event, the Building Official may issue or deny a building permit. 3. The Special Advisory Planning Board is hereby initial- ly composed of three (3) members, as follows: George Bull Beverly B. Wildt George Bull, Jr. 4. A majority of the Board may designate a representative to act for it. In the event of resignation, death or other incapacity of any member of the Board, the City shall designate a successor. Neither the members of the Board, nor its designated representative shall be entitled to any compensation for services performed hereunder. At any time the then record owners of a majority of the lots in said subdivision shall have the right to petition the City to change membership or to abolish the Board. 5. The Special Advisory Planning Board may recommend a waiver of unintentional minor violations of this provision when the building has been erected, or construction substantially advanced, provided that in the opinion of the Board such violation will not de- tract from the appearance and value of the adjoining properties. H. Any person having an interest in said subdivision or lots therein shall have the right to institute and prosecute any appropriate proceedings at law, or in equity, to pre- vent the violation of, or to recover damages for, the restrictive covenants herein contained should same be violated or an attempt to violate the same be believed imminent or intended. I. Every contract of sale or deed that the Developer, its successors and assigns, or any subsequent grantee under Developer, shall make prior to January 1, 2000, shall be made expressly subject to the provisions of this restric- tive agreement. J. Invalidation of any one of these restrictive covenants by judgment or-court order shall in no wise affect any of the other provisions hereof, which shall remain in full force and effect. 3 - 032682 SECTION II - BUFFER ZONES Buffer zones are established for the purpose of screening by the use of natural vegetation as hereinafter set forth: A. The buffer zone for screening shall extend along Seminole Road and be for a width of fifteen (15) feet measured at right angles to the west line of said road and be inter- rupted only by the one (1) street shown on said plat. That is to say, no access to the east from Seminole Road to lots one .(1) and ten (10) is permitted. The buffer zone is indicated on the plat as Tract A and Tract B and is not a part of the adjoining lot or lots. B. The Developer, for itself, its successors or assigns to each lot or area abutting the aforementioned buffer zone, separately and collectively, accepts the obligation to care for and nurture the natural vegetation in the buffer zone and to police the buffer zone to keep same free of unsightly debris, trash or other discards and otherwise maintain said buffer zones in a sightly and presentable condition. SECTION III - SINGLE FAMILY RESIDENTIAL DEVELOPMENT The lots shown on said plat, numbered one (1) through ten (10) inclusive, may be used only for single family dwellings, of not more than two (2) stories, of two (2) types, as herein- after set forth. The first or ground floor of said dwelling, to ensure the proper function of the sanitary sewer system, shall be no lower than the minimum elevation shown on each lot of the plat of Selva Marina Garden Two. No part of any dwelling shall be erected, placed, altered, or permitted on any lot nearer to the street line than twenty (20) feet nor nearer to the rear lot line than twenty (20) feet. A. Cluster or Patio Homes On each of the singular lots or consolidated lot other than the consolidation of two (2) lots, no building shall be erected, placed, altered, or permitted other than one single-family cluster or patio dwelling containing an enclosed heated and/or air conditioned living floor area of not less than twelve hundred (1,200) square feet. 1. A cluster or patio dwelling may or can be erected, placed or altered on a single lot to within one (1) inch of one side lot line, in which instance no part thereof shall be nearer to the other side lot line than ten (10) feet. 2. In the event that a portion or all of the side or side wall of the dwelling is within ten (10) feet of the side lot line, then, in that event, that portion of the-side or side wall shall contain no openings or windows. a. For the purposes of this provision, eaves, rakes, cornices and steps and similar projections shall - 4 - 040682 not be considered -as part of the building, pro- vided, however, that this shall not be construed to permit any portion of a building to encroach upon any adjoining properties. b. For the purpose of these covenants and restric- tions and/or this provision, the area herein provided upon which the dwelling may be erected, placed, altered or permitted shall be termed the "dwelling zone." C. Garages, servants' rooms and rooms used for stor- age, private laundries, or similar purposes, if provided, shall be attached to and made a part of the residence which they serve. Garages shall be provided with doors and, in the event such garages face upon any street, the doors shall be provided with an automatic opening and closing device. d. No dwelling, fence, wall, detached outbuilding, swimming pool or similar structure shall be located, placed, altered or permitted on any lot in said subdivision outside of the dwelling zone, except as hereinafter provided. (1) Only one (1) swimming pool may be located outside of the dwelling zone, provided it is located in that portion of the lot be- tween the rear-of the dwelling unit. and the rear lot line, provided no part thereof shall be within five (5) feet of the side or rear lot line. (2) Fences or walls.may be located outside of the dwelling zone provided: (a) If located in the front or side street yard they shall not exceed five (5) feet in height. (b) If located to the rear of the front or side street yard they shall not exceed seven (7) feet in height. (c)' They shall not be constructed of metal or wire. (d) Their material and color must be- simi- lar to and/or blend with the dwelling. (e) They cannot be located nearer to the side or rear lot line than one (1) inch unless the owner of the lot on the other side of said line waives this provision in writing to the Board. (3) Screened enclosures may be located only in the side and rear yards provided plans, location and concept have received prior separate approval by the Special Advisory Planning Board. 5 - 040682 B. Conventional Detached Single Family Homes In the event two (2) or more adjoining lots, as shown on said plats are combined to form one building plot, then in that event, the following restrictions shall apply: 1. No building shall be erected, placed, altered or per- mitted on any consolidated building plot as aforesaid other than one conventional detached single family dwelling of not more than two (2) stories (together with the usual outbuildings thereof), containing an enclosed heated and/or air-conditioned living floor area of not less than fourteen hundred (1,400) square feet if one story and sixteen hundred (1,600) square feet if two stories. 2. No building shall be erected, placed, altered or per- mitted on any consolidated lot in said subdivision nearer to the side lot lines of adjoining lots than ten (10) feet. a. For the purposes of this provision, eaves, rakes, cornices and steps and similar projections shall not be considered as part of the building, pro- vided, however, that this shall not be construed to permit any portion of a building to encroach upon any adjoining properties. b. For the purpose of these covenants and restric- tions and/or this provision, the area herein provided upon which the dwelling may be erected, placed, altered or permitted shall be termed the "dwelling zone." C. Garages, servants' rooms and rooms used for stor- age, private laundries, or similar purposes, if provided, shall be attached to and made a part of the residence which they serve.. Garages shall be provided with doors and, in the event such garages face upon any street, the doors shall be provided with an automatic opening and closing device. d. No dwelling, fence, wall, detached outbuilding-, swimming pool or similar structure shall be located, placed, altered or permitted on any lot in said subdivision outside of the dwelling zone, except as hereinafter provided. (1) Only one (1) detached outbuilding may be located outside the dwelling zone provided: (a) It shall not be used as a separate or secondary residence or a guest house. (b) It shall not exceed an outside hori- zontal dimension of six (6) feet by eight (8) feet. (c) The walls thereof shall be no higher than the first floor walls of the dwelling. - 6 - 040682 (d) The slope of the roof shall not be steeper than that of the dwelling. (e) It shall not be located closer to the rear or side lot lines than five (5) feet except that it may be within one (1) inch of the side or rear lot line, but in compliance with paragraph 2. a. of this section. (f) It shall be located in the rear yard, the same being defined as that portion of the lot between the rear of the dwelling built in the dwelling zone and the rear lot line. (g) The material of which it is constructed must be similar to and its color or appearance blending or compatible to the primary dwelling. (2) Only one (1) swimming pool may be located outside of the dwelling zone, provided it is located in the rear yard as defined in sub-paragraph (1) (f) above, and no part thereof shall be within five (5) feet of the side or rear lot line. (3) Fences or walls may be located outside of the dwelling zone provided: (a) They shall not exceed seven (7) feet in height. (b) They shall not be constructed of metal or wire. (c) Their material and color must be simi- lar to and/or blend with the dwelling. (d) They shall not be closer to the front or side street line than the front or side of the dwelling constructed in the dwelling zone. (e) They cannot be located nearer to the side or rear lot line than one (1) inch unless the owner of the lot on the other side of said line waives this provision in writing to the Board. (4) Screened enclosures may be located only in the side and .rear yards provided plans, lo- cation and concept have received prior separate approval by the Special Advisory Planning Board. IN WITNESS WHEREOF, the Developer, Sevilla Development Corpo- ration, Inc. , has caused this instrument to be executed by 7 - 040682 its duly authorized officers, and its corporate seal to be hereunto affixed this day of , A. D. 198_. SEVILLA DEVELOPMENT CORPORATION, INC. By. George Bull, President ATTEST: Secretary Signed, sealed and delivered in the presence of: STATE OF FLORIDA ) ss COUNTY OF DUVAL ) BEFORE ME, an officer duly authorized in the County and State aforesaid to take acknowledgments, personally appeared GEORGE BULL and BEVERLY B. WILDT, the President and Secretary respec- tively of SEVILLA DEVELOPMENT CORPORATION, INC. , a corporation existing under the laws of the State of Florida, to me well known to be the individuals and officers described in and who executed the foregoing instrument, and they severally acknowl- edged the execution thereof to be their own free act and deed as such officers thereunto duly authorized; and that the official seal of said corporation is duly affixed thereto. WITNESS my hand and official seal this day of , A. D. 198_, at ATLANTIC BEACH, County and State aforesaid. Notary Public, State of Florida at Large My commission expires: - 8 - 040682 Comp. By: NAME Date: 1111/2018 Public Works Department City of Atlantic Beach Permit No: RESA17-0024 Address: 410 Garden Street Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area(A) = 6,650 ft' Runoff Coefficient Area Lot Area Description (ft) (ft) "C" Wtd"C" Impervious 2,402 6,650 1.00 0.36 Pervious 4,248 6,650 0.20 0.13 Runoff Coefficient(C)= 0.49 Runoff Volume V= 0.49 x 6,650 x 9.3 / 12 V= 2,520 ft3 Postdevelopment Runoff Volume: Lot Area(A) = 6,650 ftZ Runoff Coefficient Area Lot Area Description (ft) (ft) "C" Wtd"C" Impervious 3,245 6,650 1.00 0.49 %ISA= 48.8% Pervious 3,405 6,650 0.20 0.10 Runoff Coefficient(C)= 0.59 Runoff Volume V= 0.59 x 6,650 x 9.3 / 12 V= 3,043 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume-Predevelopment Runoff Volume DV= 3,043 - 2,520 DV= 523 ft3 Retention W.R.Copy for Sending 1/11/2018 z Comp. By: NAME -e �k Date: 1/11/2018 Public Works Department City of Atlantic Beach Permit No: RESA17-0024 Address: 410 Garden Street Provided Storage: Elevation Area Storage (ft) (ft) (ft) BACK 8.0 72 0 BOTTOM size 18 X 4 8.5 130 51 TOB size 20 X 6.5 Elevation Area Storage (ft) (ft) (ft) SIDE 8.0 153 0 BOTTOM 51 X3 8.5 330 121 TOB 55 X 6 Elevation Area Storage (ft) (ft) (ft) 0.0 0 0 BOTTOM 0.0 0 0 TOB Inground storage=A*d*pf A=Area= 460.0 d=depth to ESHWT= 5.5 pf=pore factor= 0.3 Inground Storage= 759.0 ft3 Required Treatment Volume= 523 ft3 Supplied Treatment Volume= 810 ft3 Retention W.R.Copy for Sending 1/11/2018 OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH FLORIDA Project Name: I— er �e6jdgly a e, Permit Project Address: /0 gP�ri� As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact' your product supplier if you do not lmow the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.ilori dabuiIdin .or . Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A.EXTERIOR - 1. Swinging � f'e �-' -. � � .l��iA® fir'•` ,�,, . � .. ... .. .. . ..... . . 2. Sliding 3. Sectional 4.Roll up .5.Automatic 6.Other B.WINDOWS 1.Single hung 2.Horizontal slider 3.Casement . 4.Double hung 5.Fixed. �(��' a � Z 6.Awning r , 7.Pass-through . 8.Projected 9.Mullion i 10.Wind breaker 11.Dual action OFFICE COPY 12.'Otlier i — +y~ g ry Manufacturer Product Descriptionimitat Category/Subcate o ion of Use State# Local# C.PANEL WALL . . 1. Siding ------------- 2. Soffits, ...... ..... 3.EFS 4. Storefronts 5.Cin tarsi walls 6. Wall louvers 7.Glass block 8.Membrane 9. Greenhouse 10. Synthetic stucco 11. Other - D.ROOFING PRODUCTS shingl 1.Asphalt es - 2. Underlayments 3.Roofing fasteners �- /y�f�� 4.Nonstructural metal roof /� ����, �,�'��A� 5.Built-up roofing 6.Modified bitumen 7. Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing l 1. Wood shingles/shalces - 12.Roofing slate 13.Liquid applied roofing 14. Cement-adhesive coats 15.Roof the adhesive 16. Spray applied polyurethane roof OFFICE COPY 17. Other [;' C.a,tegory/Subcafe og ry Manufacturer Product Descriptionimitation of Use ate HUTTERS Local# 1.Accordion 2.Bahama 3. Storm panels 4. Colonial 5.Roll-up - - . 6.Equipment Other F.STRUCTURAi., 1. Wood cCOMPONENTS 2.Truss plates onnector/anchor 6"A"%-A. _ 3.Engineered lumber 4.Railing 5. Coolers-freezers 6. Concrete admixtures 7.Material 8.Insulation forms 9.Plastics 10.Deck-roof 11. Wall 12. Sheds 13. Other w G. SKYLIGHTS 1. Skylight ve( u,�, (,Copp( L � 33o3,1 OFFICE CCP�y ` 2. Other Cate o /Subcate o — -- -- g g r3' Manufacturer Product Description Limitation of Use State# Local# A.NEW EXTERIOR ENVELOPE PRODUCTS 1 . e . 2. A,Le- In addition to completing the above list of manufacturers, product description and State approval number for the products used on this Contractor shall maintain, on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and pinstallatio instructions along with this Product Approval Sheet. n I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) (Signature) Company Name: o C v6w��, OW Chi Go*� Mailing Address: c' ig �C��� �,r, _ ,✓� /y City: Wil/ State: Zip Code: '3�� Telephone Number: (� ;� ������ Fax Number: ( ) 1 Cell Phone Number: ( ) �f� ✓ ��� E-mail Address: J g 4,'6kz16� j�° - IQ FORM R405-2014 OFFICE COPY RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance) Method Applications for compliance with the 2014 Florida Building Code,Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification(usually 4 pages/may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge®-USRCSB v5.1 11/28/201711:42:01 AM Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 410 Garden Lane, Atlantic Beach, FL, 32233 1- New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 1709.50 ft2 b.Frame-Wood,Adjacent R=11.0 176.00 ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 1(0) d.NIA R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=38.0 704.00 ft2 6. Conditionedtloorarea(W) 1612 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor Dbl,U=0.75 124.22 11.Ducts R ft2 W a.Sup:Attic,Ret:Attic,AH:Garage 6 643 SHGC: SHGC=0.50 b. U-Factor. Dbi,U=0.39 110.17fF SHGC: SHGC--0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor N/A ft2 a.Central Unit 30.2 SEER:15.00 SHGC: d. U-Factor N/A ft 13.Heating systems kBtulhr Efficiency SHGC: a.Electric Heat Pump 30.2 HSPF:8.70 Area Weighted AverageOverhang Depth: 10.968 ft. Area Weighted Average SHGC: 0.382 8. FloorTypes Insulation Area 14.Hot water systems - Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1612.00 f12 a.Electric EF.0.95 b.N/A R= ft2 c.NIA R= ft2 b. Conservationfeatures None 15_Credits Pstat I certifythat this home has complied with the Florida Ener Efficient Code for Building p 9Y Y 9 T Construction through the above energy saving features which will be installed (or exceeded) Sr in this home before final inspection. Otherwise,a new EPL Display Card will be completed based on installed Code atures. v.. Builder Signature: Date:/ -17 ' U;..fir• `� �`,f � Address of New Ho City/FL Zip:tl *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/281201711:42 AM EnergyGauge®USA-v5.1- Section R405A.1 CompliantSoftware Pagel of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ToomerResidenceEnergy Calcs Builder Name: Street: 410 Garden Lane Permit Office: City,State,Zip: Atlantic Beach,FL,32233 Permit Number. Owner. Jurisdiction: Duval County Design Location: FL,Jacksonville County:: Duval(FloridaClimateZone 2) 1. New construction or existing Addition 9. Wall Types(1885.5 sgft.) Insulation Area a.Frame-Wood,Exterior R=13.0 1709.50fF 2. Single family ormultiple family Single-family b.Frame-Wood,Adjacent R=f 1.0 176.00 ft2 3. Number of units,ifmultiplefamily 1 c.WA R= ftZ 4. Number of Bedrooms(Bedrms In Addition) 1(0) d.N/A R= fF 10.Ceiling Types (704.0 sgft-) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=38.0 704.00 ft 6. Conditionedfloorarea abovegrade(ftZ) 1612 b.N/A R= ft2 Conditionedfloorarea belowgrade(ttZ) 0 c.WA R= ftZ 11.Ducts R ft2 7. Windows(234.4 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 643 a. U-Factor. Dbl,U=0.75 124.22 ftZ SHGC: SHGC=0.50 b. U-Factor Dbl,U=0.39 110.17ftZ 12.Cooling systems kBtultlr Efficiency SHGC: SHGC--0.25a.Central Unit 302 SEER:15.00 c. U-Factor WA ft SHGC: 13.Heating systems kBtultlr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 30.2 HSPF:8.70 SHGC: Area Weighted AverageOverhang Depth: 10.968 ft. Area Weighted Average SHGC: 0.382 14. atersystems - 8. FloorTypes (1612.0 sgft.) Insulation Area a_.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1612.00 ft b. Conservationfeatures b.N/A R= ft= None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.145 Total Proposed Modified Loads: 35.43 PASS Total Baseline Loads: 37.31 I hereby certify that the plans and specifications covered by Review of the plans and 1 this calculation are in compliance with the Florida Energy specifications covered by this Code. ThOmaS V calculation indicates compliance Digitally signed by ThomasV Platania with the Florida Energy Code. �. s••::::�••••. -=•_.=••°. .;_.^. Date:2017.112818:11.49-05'00' .S:wtic•. tom PREPARED BY: Platanla _ Before construction is completed if� DATE: this building will be inspected for compliance with Section 553.908 ' CAC1815 ProCalcs, L i p Florida Statutes. r �C I hereby ce ' that t uilding^ des rfed,is in co pliance ` �i•C -0,� with the Florid En de. ` �?b iNLT1 r` r.' OWNER/ NT' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017 this project requires an envelope leakage test report with envelope leakage no greater than 5.0 ACH50(R402.4.1.2). 11/28/201711:42 AM EnergyGaugeOUSA-v5.1-Section R405.4.1 CompliantSoftware Page 1 of 5 FORM R405-2014 PROJECT Title: Toomer Residence Energy Cal Bedrooms: 1 Address Type: Street Address Building Type: User ConditionedArea: 1612 Lot# Owner Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: RotateAngle: 90 Street: 410 Garden Lane Permit Office: Cross Ventilation: No County: Duval Jurisdiction: Duval County Whole House Fan: No City,State,Zip: Atlantic Beach, FamilyType: Single-family FL, 32233 New/Existing: Addition Comment CLIMATE V/ IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 07.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Entire House 1612 15164.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Hers 104 925.6 No 0 1 Yes Yes Yes 2 Laundry 44 391.6 No 0 1 Yes Yes Yes 3 Office 52 462.8 No 0 1 Yes Yes Yes 4 Kitchen 330 2871 Yes 1 1 Yes Yes Yes 5 Dining Room 189 1323 No 0 1 Yes Yes Yes 6 Master Bathroom 135 1107 No 0 1 Yes Yes. Yes 7 His 30 210 No 0 1 Yes Yes Yes 8 Master Bedroom 238 1856.4 No 0 1 1 Yes Yes Yes 9 Foyer 44 308 No 0 1 Yes Yes Yes 10 Living Room 446 5708.8 No 4 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR Value Area Joist R Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation Hers 21 ft 0 104 ftZ _, 1 0 0 2 Slab-On-Grade Edge Insulation Laundry 5.5 ft 0 44 ftZ -- 1 0 0 3 Slab-On-Grade Edge Insulation Office 6.5 ft 0 52 it2 -- 1 0 0 4 Slab-Ort-Grade Edge Insulation Kitchen 30 ft 0 330 ftZ ___ 1 0 0 5 Slab-On-Grade Edge Insulation Dining Room 1 ft 0 189 IF _— 1 0 0 6Slab-On-Grade Edge Insulation Master Bathroom 11ft 0 135 ftZ __ 1 0 0 7 Slab-On-Grade Edge Insulation His 1 ft 0 30 ftZ _— 1 0 0 11/28/201711:42 AM EnergyGauge®USA-v5.1-Section R405.4.1 CompliantSoftware Page 2 of 5 FORM R405-2014 FLOORS # FloorType Space Perimeter PerimeterR Value Area Joist R Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulation Master Bedroom 241t 0 238 ft2 _- 1 0 0 9 Slab-On-Grade Edge Insulation Foyer 8 ft 0 44 fF 1 0 0 10SIab-On-Grade Edge Insulation Living Room 70 ft 0 446 ft2 _- 1 0 0 ROOF V/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Compositionshingles 733 ft2 102 ft2 Medium 0.4 No 0.9 No 38 16.3 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 No attic Unvented 0 704 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) Hers 0 Blown 104 ft2 0.11 Wood 2 Under Attic(Unvented) Laundry 0 Blown 44 ft2 0.11 Wood 3 Under Attic(Unvented) Office 0 Blown 52 ft2 0.11 Wood 4 Under Attic(Unvented) Kitchen 0 Blown 120 ft2 0.11 Wood 5 Under Attic(Unvented) Master Bathroom 0 Blown 88 ft2 0.11 Wood 6 Under Attic(Unvented) Master Bedroom 0 Blown 42 ft2 0.11 Wood 7 Under Attic(Unvented) Living Room 0 Blown 254 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below R_-Value Et In El In Area R-NIghle Fraction Ahsor Grade% _ 1 S-->W Exterior Frame-Wood Hers 13 13 0 7 8 99.7 ft2 0 0.23 0.4 0 _2 W=>N Exterior Frame-Wood Hers 13 8 0 7 8 61.3 ft2 0 0.23 0.4 0 _3 S=>W Exterior Frame-Wood Laundry 13 5 6 7 8 42.2 W 0 0.23 0.4 0 _4 S-->W Exterior Frame-Wood Office 13 6 6 7 8 49.8 ft2 0 0.23 0.4 0 _ 5 N=>E Exterior Frame-Wood Kitchen 13 15 0 8 0 120.0 f12 0 0.23 0.4 0 _6 S=>W Exterior Frame-Wood Kitchen 13 15 0 7 8 115.0 ft2 0 0.23 0.4 0 7 E=>S Garage Frame-Wood Kitchen 11 22 0 8 0 176.0 ft2 0 0.23 0.4 0 _ 8 S=>W Exterior Frame-Wood Master Bathro 13 11 0 7 8 84.3 ft2 0 0.23 0.4 0 _ 9 N=>E Exterior Frame-Wood MasterBedroo 13 10 0 7 10 78.3 ft2 0 0.23 0.4 0 _10 W-->N Exterior Frame-Wood Master Bedroo 13 14 0 7 10 109.7 ft2 0 0.23 0.4 0 _11 E=>S Exterior Frame-Wood Foyer 13 8 0 7 0 56.0 ft2 0 0.23 0.4 0 _12 N=>E Exterior Frame-Wood Living Room 13 22 0 16 5 361.2 ft2 0 023 0.4 0 _13 E=>S Exterior Frame-Wood Living Room 13 8 0 16 5 131.3 ft2 0 0.23 0.4 0 _14 S-->W Exterior Frame-Wood Living Room 13 8 0 16 5 131.3 ft2 0 0.23 0.4 0 15 W-->N Exterior Frame-Wood Loring Room 13 16 0 8 5 134.7 ft2 0 0.23 0.4 0 11/28/201711.42 AM EnergyGauge@)USA-v5.1-Section R405.4.1 CompliantSoftware Page 3 of 5 FORM R405-2014 WALLS Adjacent Omt Space Cavity Width Height Sheathing Framing Solar Below El In Et In Area RA/aille Eractinn AbSor 16 S=>W Exterior Frame-Wood Living Room 13 2 0 8 5 16.8 ft2 0 0.23 0.4 0 17 N=>E Exterior Frame-Wood Living Room 13 14 0 8 5 117.8W 0 0.23 0.4 0 DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 E=>S Wood IGtchen None .46 3 6 8 20 ft2 WINDOWS Orientationshown is the entered orientation=> chan edto As Built rotated90 degrees). Wall Overhang V/ # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S-->W Skylt Vinyl Low-E Double Yes 0.39 0.25 8.0 1112 0 ft 0 in 0 ft 0 in None None 2 S=>W 3 Vinyl Low-E Double Yes 0.39 0.25 4.2 ft2 1 ft 0 in 1 ft 0 in None None 3 S=>W 4 Vinyl Low E Double Yes 0.39 0.25 8.3 fl 1 ft 0 in 1 ft 0 in None None 4 S-->W Skylt Vinyl LowwE Double Yes 0.39 0.25 8.0 ft2 0 ft 0 in 0 ft 0 in None None 5 N=>E 5 Vinyl Low-E Double Yes 0.39 0.25 8.3 ft2 22 ft 0 in 1 ft 0 in None None 6 S-->W 8 Vinyl Low-E Double Yes 0.39 0.25 4.2 ft2 1 it 0 in 1 ft 0 in None None 7 S=>W 8 Vinyl Low-E Double Yes 0.39 0.25 4.2 ft2 1 ft 0 in 1 ft 0 in None None 8 S-->W Skylt Vinyl Low-E Double Yes 0.39 0.25 8.0 ft2 0 ft 0 in 0 ft 0 in None None 9 N=>E 9 Vinyl Low-E Double Yes 0.75 0.5 31.1112 16 ft 0 in 1 ft 0 in None None 10 W->N 10 Vinyl Low-E Double Yes 0.75 0.5 22.0 ft2 1 ft 0 in 9 It 1 in None None 11 E=>S 11 Vinyl Low-E Double Yes 0.75 0.5 40.0 ft2 30 ft 0 in 1 It 0 in None None 12 N=>E 12 Vinyl Low-E Double Yes 0.39 0.25 12.0 ft2 1 ft 0 in 1 ft 0 in None None 13 E=>S 13 Vinyl Low-E Double Yes 0.39 0.25 45.0 ft2 1 ft 0 in 1 ft 0 in None None 14 W=>N 15 Vinyl Low-E Double Yes 0.75 0.5 31.1 ft2 10ft 6 in 1 ft 0 in None None GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 484 IF 484 ft2 66 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000299 1263.7 69.37 130.47 .2833 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.7 30.2 kBtu/hr 1 sys#1 11128/201711:42 AM EnergyGauge®USA-v5.1-Section R405.4.1 CompliantSoftware Page 4 of 5 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 30.2 kBtuihr 1007 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.95 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert# CompanyName System Model# CollectorModel# Area Volume FEF None None ft DUCTS —Supply— —Return— Air CFM 25. CFM25 HVAC# # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 643 tie Attic 643 fte Default Leakage Garage (Default)c(Defauft)c 1 1 TEMPERATURES ProgramableThermostat Y Ceiling Fans: CoolingJan Feb Mar r ]May �X Jun Jul Au rl Se Oct Nov Dec HeatinJan Feb Mar E Fpr f Ma [ Jun Jul Aug Sep f Oct Nov Dec Ventin Jan Feb Mar WApr [ Ma [ Jun Jul Au Sep [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) PM 68 68 68 68 68 68 68 68 68 68 66 66 111281201711:42 AM EnergyGauge®USA-v5.1-Section R405A.1 CompliantSoftware Page 5 of 6 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 410 Garden Lane Permit Number: Atlantic Beach,FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). ThdDuilding official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law[Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The'EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). Thebuilding thermal envelopeshall be constructed to limit air leakage in accord arice with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. Thebuilding thermal envelopeshall complywith Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allowfor differential expansionand contraction. R402.4.1.1 Installation. Thecomponents of the building thermal envelopeas listed in Table R402.4.1.1 shall be installed in accordancewith the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicableto the method of construction. Where required by the code official,an approvedthird party shall inspect all components and verify compliance. R402.4.1.2 Testing. Thebuilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding?air changes per hour in Climate Zones land 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(0,(g),or(i)or an approvedthird party. A written report of the results of the test shall be signed by the party conducting the test and providedto the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exteriorwindows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstrippingor other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exteriordoors for continuous ventilationsystems and heat recoveryventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces.Newwood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no morethan 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independentlaboratoryand listed and labeled by the manufacturer. Exception: Site-builtwindows,skylights and doors. O R402.4.4 Recessed lighting. Recessedluminaires installed in the building thermal envelopeshall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk betweenthe housing and the interiorwall or ceiling covering. R403.1.1 Thermostat provision(Mandatory).Atleast one thermostatshall be providedfor each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory).Heapumps having supplementaryelectric-resistance heat shall have controls that, except during defrost,prevent supplemental heat operationwhen the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)llducts,air handlers,and filter boxes and building cavities that form the primary air containment passagewaysfor air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordancewith Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(%(g),or(i),Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakageshall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturers air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakageshall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(2513a)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakageshall be less than or equal to 3 cfm(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakagetest is not required for ducts and air handlers located entirelywithin the building envelope. 2. Duct testing is not mandatoryfor buildings complying by Section R405 of this code. 11/28/2017 11:43 AM EnergyGauge®USA-v5.1- Section R405.4.1 Compliant Software Pagel of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanicaetystem piping capable of carrying fluids above 105°F(41°C)or below 55°F(13°C)shall be insulated to a minimum of.R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulatindiot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storagewater heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either commercially available heat trap or a downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold waterline located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). Q R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. ServiceNater heating systems shall be equipped with automatictemperaturecontrols capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperaturesetting range shall be from,100°F to 140°F(38°C to 60°C). • R403.4.4.1.2 Shutdown. Aseparate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Waterheating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriatewater heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solaisystems for domestic hot water production are rated by the annual solar energyfactor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,and SRCC Standard TM-1,Solar Domestic Hot Water System and ComponentTest Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientationwithin 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). Thebuilding shall be provided with ventilationthat meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilationsystem is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). ThEfollowing sections are mandatoryfor cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heatingand cooling equipmentshall be sized in accordancewith ACCA Manual S based on the equipmentloads calculated in accordancewith ACCA Manual or other approved heating and cooling calculation methodologies,based on building loads for the directional orientationof the building.The manufacturerand model number of the outdoorand indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allowdesigner safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaustsystems. • R403.6.1.1 Cooling equipment capacity. Cooling)nly equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greaterthan the total load calculated according to the procedure selected in Section 403.6,or the closest availablesize provided by the manufacturer's product lines.The corresponding latent capacityof the equipmentshall not be less than the calculated latent load. 11/28/2017 11:43 AM EnergyGaugeOUSA-v5.1- -Section R405.4.1 Compliant Software Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) ThEpublished valuefor AHRI total capacityis a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-onlyequipment.This selection shall be used to select cooling-onlyequipment.This selection shall be based on the outdoordesign dry bulb temperaturefor the load calculation(or entering water temperaturefor water-source equipment),the blowercfm provided by the expanded performance data,the design valuefor entering wet bulb temperatureand the design valuefor entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoordry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipmentsizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registeredengineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordancewith good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heatpumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greaterthan the design cooling load. R403.6.1.2.2 Electric resistance furnaces. ElectriQesistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. Thecapacity of fossil fuel heating equipmentwith natural draft atmospheric burners shall not be less than the design load calculated in accordancewith Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residencesequiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additionalloads caused by major entertainmentevents,shall have equipmentsized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separatecooling or heating system is utilized to provide cooling or heating to the major entertainmentareas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systemserving multiple dwelling units shall complywith Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snovend ice-melting systems,supplied through energyservice to the building,shall include automatic controls capable of shutting off the system when the pavementtemperatureis above55°F,and no precipitation is falling and an automaticor manual control that will allowshutoff when the outdoor temperature is above40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). Thernergyrequirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordancewith ANSI/APSP-15.The energy requirements for portablespas shall be in accordancewith ANSI/APSP-14. Q R403.9.1 Pool and spa heaters. Allpool heaters shall be equippedwith a readily accessible on-off switch that is mounted outside the heaterto allowshutting off the heaterwithout adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. Algas-and oil-fired pool and space heaters shall havea minimum thermal efficiency of 82 percentfor heaters manufactured on or afterApril 16,2013 when tested in accordancewith ANSI Z 21.56.Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heapump pool heaters shall have a minimum COP of 4.0 when tested in accordancewith AHRI 1160,Table 2,Standard Rating Conditions-LowAir Temperature.A test reportfrom an independent Iaboratoryis requiredto verify procedure compliance.Geothermal swimming pool heat pumps are not requiredto meetthis standard. O R403.9.2 Time switches. Timeswitches or other control method that can automaticallyturn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recoverypool heating systems. 3. Where pumps are powered exclusivelyfrom on-site renewable generation. O R403.9.3 Covers. Heatedswimming pools and inground permanentlyinstalled spas shall be equipped with a vapor-retardantcover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoorpools deriving over 70 percent of the energyfor heating from site-recoveredenergy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). Aminimum of 75 percent of the lamps in permanentlyinstalled lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanentlyinstalled lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltagdighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuegas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. Allducts not entirely inside the building thermal envelopeshall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilingsshall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 11/28/2017 11:43 AM EnergyGauge®USA-v5.1- -Section R405.4.1 Compliant Software Page of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Toomer Residence Energy Calcs Builder Name: Street: 410 Garden Lane Permit Office: City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: Duval County Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate.and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/28/2017 11:43 AM EnergyGaugeOUSA-v5.1-Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Toomer Residence Energy Calcs Builder Name: Street: 410 Garden Lane Permit Office: City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Design Location: FL,Jacksonville Jurisdiction: Duval County Cond.Floor Area:: 1612 sq.ft. Cond.Volume: 15164 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: CFM(50): C: n: R: ELA: Single or Multi Point Test Data HOUSE PRESSURE FLOW: I EgLA' ACH: SLA: ACH(50) *For prescriptive projects, tested leakage must be <=7 ACH(50). For performance projects, tested leakage must be<= the ACH(50) shown on Form R405-2014 for this project. R402.4.1.2 Testing.Thebuilding or dwelling unit shall be tested and verified as having an air leakagerate of not exceeding7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(0,(g),or(i)or an approvedthird party.A written report of the results of the test shall be signed by the party conducting the test and providedto the code official.Testing shall be performed at any time after creation of all penetrationsof the building thermal envelope. During testing: 1.Exteriorwindows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exteriordoors for continuous ventilationsystems and heat recoveryventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing shall be conducted by either kxET I hereby certify that the above envelope leakage individuals as defined in Section C��� , _ performance results demonstrate compliance 553.993(5)or(7), Florida Statutes or with Florida Energy Code requirements in individuals licensed as set forth in ,rr,f •,` 4-„ , O accordance with Section R402.4.1.2. Section 489.105(3)(f), (g), or(i) or an approved third party. A written report SIGNATURE: of the results of the test shall be signed by the third party conducting , 9 the test and provided to the code dD Ywas PRINTED N . A'Me� DATE: v`� BUILDING OFFICIAL: DATE: 11/28/2017 11:43 AM EnergyGaugeOUSA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 Load Short Form _'Digitally signed by Job: Nov 28, Residence wrightsofte Thomas V Date: Nov 28 20y �=.Thomas V Platania Entire House By: Nate Paslay Platdnia Date:2017.11.28 ProCaIcs, LLC 18:10:59-05'00' P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1816254 RTIN#0105474 Project • • For: Toomer Residence 410 Garden Lane,Atlantic Beach, FL 32233 Design Information Htg Clg Infiltration Outside db(°F) 34 96 Method Blower door Inside db(°F) 70 75 Shielding/stories 3(partial)/2 Design TD(°F) 37 21 Pressure/AVF 50 Pa/1769 cfm Daily range - M Inside humidity(%) 50 50 Moisture difference(gr/Ib) 32 46 HEATING EQUIPMENT COOLING EQUIPMENT Make Trane .Make Trane Trade ASPEN Trade ASPEN Model 4TWX5030A1000A Cond 4TWX5030A1000A AHRI ref N/A Existing Coil 4TEE3F31B1000A AHRI ref N/A Existing Efficiency 8.7 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24160 Btuh Heating output 28200 Btuh @47°F Latent cooling 6040 Btuh Temperature rise 51 OF Total cooling 30200 Btuh Actual air flow 503 cfm Actual air flow 1007 cfm Air flow factor 0.017 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.84 Capacitybalance point=34 OF Backup:Trane BAYHTR1408000A In ut=8 kW Output=27297 Btuh 100 AFUE ROOM NAME Area Htg load CIg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Hers 104 2885 1451 50 61 Laundry 44 843 334 15 14 OffiCe 52 1161 972 20 41 Kitchen 330 4524 3765 79 157 Dining Room 189 0 485 0 20 Master Bathroom 135 1950 1275 34 53 His 30 0 0 0 0 Master Bedroom 238 4986 7128 87 298 Foyer 44 1690 806 30 34 Living Room 446 10745 7888 188 330 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft— 2017-Nov-2811:47:51 Right-Suite®Universal 2018 18.0.04 RSU25613 Page 1 f�C� ...ResIdencelWorkingDrawingslToomerResidence.rup Calc=MJ8 FrontDoorfaces: E Entire House 1612 28784 24105 503 1007 Other equip loads 0 0 Equip.@ 1.00 RSM 24105 Latent cooling 4521 TOTALS I 1612 I 28784 I 28626 I 503 i 1007 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W rightsoft 2017-Nov-28 11:47:51 ^ti ....... . .._....,— RighlSuite®Universal 2018 18.0.04 RSU25613 Page / iC� ...Residence\Working Drawings\Toomer Residence.rup Calc=MJ8 Front Door laces: E � . BuildingAnalysis Job: ToomerResidence 11�f1C14�hSoft$ a Date: Nov 28,2017 Entire House By: Nate Paslay ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.PmCalcs.Net License:CAC1815254 RTIN#0105474 Project • • For: Toomer Residence 410 Garden Lane,Atlantic Beach, FL 32233 D 'sign Conditions Location: Indoor: Heating Cooling Jacksonville NAS, FL, US Indoor temperature(°F) 70 75 Elevation: 23 ft Design TD(°F) 37 21 Latitude: 30°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 32.2 46.2 Dry bulb(°F) 34 96 Infiltration: Daily range(°F) - 16 ( M ) Method Blower door Wet bulb(°F) - 77 Shielding/stories 3(partial)/2 Wind speed(mph) 15.0 7.5 Pressure/AVF 50 Pa/1769 dm Component Btuh/ft2 Btuh %of load Walls 3.4 6083 21.1 D"� Glazing 22.4 6486 22.5 vel filtration Doors 14.2 285 1.0 Ceilings 0.8 543 1.9 Floors 4.7 7580 26.3 Infiltration 3.5 6790 23.6 Ducts 1016 3.5 Piping 0 0 Glazing Humidification 0 0 Roos Ventilation 0 0 aher Adjustments 0 Total 1 1 28784 100.0 Component Btuh/fF Btuh %of load Walls 2.6 4685 19.4 Glazing 38.0 11007 45.7 Nblls Internal Cairn Doors 13.3 266 1.1 Ceilings 0.8 562 2.3 Ducts Floors 0 0 0 Infiltration 1.2 2325 9.6 Irffttion Ducts 511 2.1 Ventilation 0 0 Internal gains 4750 19.7 lings Blower 0 0 Adjustments 0 Ga2ir13 Total 1 1 24105 100.0 Latent Cooling Load=4521 Btuh Overall U-value=0.131 Btuh/ft-°F Data entries checked. wrightsoft- 2017-Nov-2811:47:51 .Qr ---• - Right-Suite®Universal 2018 18.0.04 RSU25613 Page 1 ACCX ...Residence\Working Drawings\Toomer Residence.rup Calc=MJ8 Front Door faces: E W6`I�htS�f#® Project Summa Job: Toomer Residence Date: Nov 28,2017 Entire House By: Nate Paslay ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 RTIN#0105474 Project Information For: Toomer Residence 410 Garden Lane,Atlantic Beach, FL 32233 Notes: Elite Custom Homes&Renovations, Inc. 2304 Peach Drive Jacksonville, FL 32246 Design Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 OF Outside db 96 OF Inside db 70 OF Inside db 75 OF Design TD 37 OF Design TD 21 OF Daily range M Relative humidity 50 % Moisture difference 46 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 27768 Btuh Structure 23594 Btuh Ducts 1016 Btuh Ducts 511 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28784 Btuh Use manufacturers data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24105 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/2 Pressure/AVF 50 Pa/1769 cfm Structure 4209 Btuh Ducts 313 Btuh Central vent(0 cfm) 0 Btuh Heatin Cooling (none) Area(ftj 161T 1612 Equipment latent load 4521 Btuh Volume(ft) 15161 15161 Air changes/hour 0.67 0.40 Equipment Total Load (Sen+Lat) 28626 Btuh Equiv.AVF(cfm) 169 102 Req.total capacity at 0.80 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade ASPEN Trade ASPEN Model 4TWX503OA1000A Cond 4TWX503OA1000A AHRI ref N/A Existing Coil 4TEE3F31 B1000A AHRI ref N/A Existing Efficiency 8.7 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24160 Btuh Heating output 28200 Btuh @ 47°F Latent cooling 6040 Btuh Temperature rise 51 OF Total cooling 30200 Btuh Actual air flow 503 cfm Actual air flow 1007 cfm Air flow factor 0.017 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.84 Capacitybalance point=34 OF Backup:Trane BAYHTR1408000A Input=8 kW, Output=27297 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wrllghtsoft� 2017-Nov-2811:47:51 �_ ��•• ---• Right-Suite®Universal 2018 18.0.04 RSU25613 Page 1 ACCCA, ...Residence\Working Drawingswoomer Residence.rup Calc=MJB Front Door faces: E wrightsoft• Right-J® Worksheet Job: Toomer Residence Entire House Date: Nov 28,2017 ProCalcs, LLC By: Nate Paslay P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 RTIN#0105474 1 Room name Entire House Hers 2 Exposed wall 176.0 It 21.0 ft 3 Room height 9A It 8.9 ft heat1cool 4 Room dimensions 8.0 x 13.0 ft 5 Room area 1612.0 ft' 104.0 ft' Ty Construction U-valueOr I HTM I Area (ft') I Load I Area (ft2) I Load number (Btuh/ft'-.F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool j Gross I N/P/S j Heat I Cool j Gross N/P/S j Heat I Cool 6 12C-0sw 0.091 n 3.32 2.64 643 600 1991 1585 24 24 81 64 1OD-v 6.750 n 27.38 16.01 31 0 852 498 0 0 0 0 2 glazing,or low-e 0.390 n 14.23 _ _12.01 _ _12. 0 _- 171 __144 ._- 0 __. 0 , 0 „p V+J 12C-0sw 0.091 n 3.32 2.64 148 140 464 370 6 0 0 0 11 L-C 2 glazing,driow-e 0,390 n 14.23 12.80 8 0 119 107 0 0 0 0 lj�� 12C-0sw 0`.091 a 3.32 - 2.64 187 102 340 271 0 0 -0 0 IOD-v 0.750 a 27.38 18.01 40 40 1095 720 0 0 0 0 2,glazing,dr low-e 0.390 a 14.23 35.16 45 0 641 1582 0 0 _ 0, 0 W... ._ 12C-Osw __. 0.091 ..e_ 3.32 2.64 -- -_25 25 82 65 .. 0 __ 0 4 0 W 12C-0sw :, _. .0.091 s- __ 3.32 _ 2.64 115 . 115 382 304 0 0 0 .. 0' 12C-Osw 0.091 s 3.32 2.64 468 447 1484 1181 115 115 383 305 i2 glazing,cir low-e 0.390 s 14.23 14.80 17 17 237 247 0 0 0 0 2 glazing,dr low-e 0.390 s 14.23. _ 14.80 4_ 4 _ __ 59 _62 0 _ 0 0 0 _-W` _ 12C-Osw-' 0.041 _,s 3.32 : - 2.64 33 33 110. 88 0 0 0 _ 0 12C-0sw 0.091 w 3.32 2.64 306 197 653 520 61 61 204 162 1OD-v 0.750 w 27.38 18.01 31 31 852 560 0 0 0 0 LLL-��� 2 nlazino.dr low-e 0.750 w 27.38 56.48 78 0 _2135 4406 0 0 0-- 0 PI Partition Wall 0.101 - ` 3.70 1.94 176 156 _ 577 303 0 0 0 0 -. .D 11D0 - _': _.: 0.390 n -. 14.23 "_ 13.28 __ 20 20- _ ..285 266 .- 0 0 . 0 0 C - 16C38ml 0.026 - 0.95-_ ,1.24 296 296 _ 281 366 0 _ 0 _ 0 0 �j 16X1938ml - 0.026 - 0.68 0.51 408 386 262 196 104 96 66 49 �-G Sky glazing,small, 0.390 _ s_ -.14.2& 63.07 23 .. -_0 326 --1445 __ 8 - _ 0 109 482 F _ 22A4pm _ 1.180 - 43.07 0.00 - 1612 176 7580 0 _ 104 21 904 0 61 c)AED excursion 1 1 1237 -38 Envelope loss/gain 20978 16519 1747 1025 12 a) Infiltration 6790 2325 710 243 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 0 0 Appliances/other 3600 0 Subtotal(lines 6 to 13) 27768 23594 2456 1267 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 27768 23594 2456 1267 15 Dud loads 4% 2% 1016 511 17% 15% 429 184 Total room X,required(cfm) I 1 ( 28784 5031 24105 10071 I 1 2885 501 1 611 Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. -r•#.F- wrlgtitza*t' 2017-Nov-2811:47:51 -� - - Right-Suite®Universal 2018 18.0.04 RSU25613 Pagel Residence\Working Drawings\Toomey Residence.rup Calc=MJ8 Front Door faces: E + - wrightsoft Right-J® Worksheet Job: Toomer Residence Entire House Date: Nov 28,2017 ProCalcs, LLC By: Nate Paslay P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 RTIN#0105474 1 Room name Laundry Office 2 Exposed wall 5.5 If 6.5 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 8.0 x 5.5 ft 8.0 x 6.5 It 5 Room area 44.0 ft' 52.0 ft2 T Construction U-value Or HTM Area (ftp) Load Area ft') Load Ty number (Btuh/ft2-°F (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (tt) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-0sw 0.091 n 3.32 ._ 2.64. 10 10 34 27 12 12 _ 40 32 10D-v 0.750 n 27.38 16.01 A 0 0 0 0 0 0 0 2 glazing,Gr low-e 0.390 n 14.23 -12.01 0_ 0 _ 0 0 0 0 0 0 y1 12C-0sw 0.091 n 3.32 2.64 0 0 0 0 0 0 0 0 11 T_ G 2 glazing,dr low-e _ 0.390 n 14.23 12.80 -0 0 0 0 0 0 0 0 12C-0sw 0.091 a 3.32 2.64 0 0 -0 0 0 0 0 0 10D-v 0.750 a 27.38 18.01 0: 0 0 0 0 0 0 0 2 glazing,dr lower _- -_ - 0.390 ,.e _ 14.23 35.16 -.. _.0 - - 0 _- - - - 0 - - - 0 _- 0 0- -0 .0 W_. 12"sw. .- 0.091 a 3.32 2.64 -1.0 - 0 --,0 _ - 0 0_ -- 0 - W _ _ 12C-0sw- - .` 0.091 s 3.32: 2.64_ .0 0 -0 . 0 -0 0 0 ;0 LL'Ll12C-0sw 0.091 s 3.32 2.64 49 45 148 118 58 49 164 130 2 glazing,dr low-e 0.390 s 14.23 14.80 4 4 59 62 8 8 119 123 2 glazing,dr low-e 0.390 _ s 14.23 14.80 0 01 0 0 0 0 0 0 W.__. .12C-0sw: 0.091 s. 3.32 '__.. 2.64_ 0 ,0 -0 0 0 0 _ ` - 0 0 12C-0sw 0.091 w 3.32 2.64 0 0 0 0 0 0 0 0 10D-v 0.750 w 27.38 18.01 0 0 0 0 0 0 0 0 VL C� 2 glazing,dr low-e 0.750 w 27.38 _ 56.48 0 0 0 0- 0 0 0 0 P Partition Wall 0.101 - 3.70 1.94 0 0 0 0 0 0 0 0 11130.. _ 0.391 _ n 14.23 .: 13.28 0 0 A 0 0 0 0 -0 C- 16C38ml 0.026 - 0.95 1.24 0 0 0 0 0 0 0 0 16X19-38ml 0.026 - 0.68 0.51 44. 44 30 22 52 44 30. 23 Sky glazing,small, _°- - 0.390 s-.. .14.23 -"63.07 :_0 . _0 0 _0 8 ..__ "..0 109.. 482 F 22A-tpm 1.180 - 43.07 0.00 44 ,6 237 -0 52 7 280 0 61 c)AED excursion 1 -9 -26 Envelope losstgain 1 509 220 1 1 742 764 12 a) Infiltration 209 71 247 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(fines;6 to 13) 717 292 988 849 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 717 292 988 849 15 Dud loads 17% 15% 125 42 17% 15% 172 123 AirTotrequired(dm)l room load I I I 843 3 4I 41 I I 11201 9721 41 Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. -r�+- wrlgF�t.ott- 2017-Nov-28 11:47:51 - - Rig ht-Su ite®Universal 2018 18.0.04 RSU25613 Page 2 Ar C�N ..Residence\Working Drawings\Toomer Residence.rup Calc=MJ8 Front Door faces: E wrightsoft, Right-JO Worksheet Job: Toomer Residence Entire House Date: Nov 28,2017 By: Nate Paslay ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34968 Phone:772-682-0700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 RTIN#0105474 1 Room name Ktchen Dining Room 2 Exposed wall 30.0 ft 0 ft 3 Room height 8.7 It heat/cool 7.0 ft heat/cool 4 Room dimensions 22.0 x 15.0 ft 14.0 x 13.5 ft 5 Room area 330.0 ft' 189.0 ft' Ty Construction U-value Or HTM Area (f t') Load Area Load number (Btuh/f t'-°F (Bt uh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VIJ 12C-0sw 0.091 n 3.32 2.64 0 0 0 0 0 0 0 0 LI---G 10D-v 0.750 n 27.38 16.01 0 0 0 0 0 0 0 0 2 glazing,cfr;Iow-e - 0.390 n- 14.23 -12.011 -0 0 0 0 --0 - 0 '_0 0 y! 12C-0sw 0.091 n 3.32 2.64 148 140 464 370 0 0 0 0 11 I-G 2 glazing,dr low-e 0.390_ n 14.23 12.80 a 0 119 107 0 0 0 0 12C-0sw 0:091 a 3.32 :- 2.64 0, 0 0 0 0 0 0 0 1013-v 0.750 a 27.38 18.01 0 0 0 0 0 0 0 0 .. 2 glazing,dr lower 0.390 - e 14.23 _, 35.16 0_ - 0 0 _ 0 -. 0 0 0 - - _, 0 W 12C-0sw 0.091 a 3.32 2.64 25 2582 65 0 0 0 0 W ;_ 120,Osw ;_',-. _-0.091 s- 3.32. ..2.64 115 115 382 :_ 304 0 0 _ 0 0 �1 12C-0sw 0.091 s 3.32 2.64 0 0 0 0 0 0 0 0 F-G 2 glazing,dr low-e 0.390 s 14.23 14.80 0 0 0 0 0 0 0 0 :i 2 glazing,cir low-e _0.390 s 14.23 14.80 0 0 0 _ 0 0 0.- 0 0 W 12C-0sw -_.__. 0.091 _ _s 3.32 . 2.64 33 - 33- 110 88'. 0 0 0 0 12C-0sw 0.091 w 3.32 2.64 0 0 0 0 0 0 0 0 10D-v 0.750 w 27.38 18.01 0 0 0 0 0 0 0 0 2 glazinq.dr low- 0.750_ w 27.38 - - 56.48 0 0 - _ 0 0- 0 0 0 0 PI Partition Wall - 0.101 - 3.70 ' 1.94 176 156 577 303 0 0 0 0 D 11D0-. ... 0.390 - n _-14.23 13.28 .. :.20 20-_ :285 266- 0 0 0 .0 C,- - 16C-38ml _0.026 0.95 _. 1.24 0 _. ..- 0 _ 0 0 0 0 - 0 ._-- .0 �j 16X19-38ml 0.026 - 0.68 0.51 120 120 82 61 0 0 0 0 �--G Sky glazing,small, ._ --0.390 _ s 114.23 _ 63.07 _.-0 -0 0 0 0 0.:- 0 - . 0 F- 22Ajpm 1.180 43.07 0.00 330 30 1292 0 189 0 0 0 6 c)AED excursion -1141 1 1 115 Envelope loss/gain 3392 1448 1 1 0 15 12 a) Infiltration 1132 388 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 1700 500 Subtotal(lines 6 to 13) 4524 3765 0 485 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4524 3765 0 485 15 Dud loads -0% 0% 0 0 -0% 0% 0 0 I I Airrequired(dm)Totl room load I I I 45791 31571 I I 0 115 4201 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A- wrlgFNtsoYt- 2017-Nov-2811:47:51 1.9 �- Right-Suite@ Universal 2018 18.0.04 RSU25613 Page Residence\Working Drawings\Toomer Residence.rup Calc=MJ8 Front Doorfaces: E +�- wrightsoft, Right-J® Worksheet Job: Toomer Residence Entire House Date: Nov 28,2017 ProCalcs, LLC By: Nate Paslay P.O.Box 882032,Port Saint Lucie,FL 34968 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 RTIN#0105474 1 Room name Master Bathroom His 2 Exposed wall 11.0 It 0 It 3 Room height 8.2 It heat/cool 7.0 ft heat/cool 4 Room dimensions 1.0 x 134.8 It 5.5 x 5.5 ft 5 Room area 134.8 ft' 30.3 ft' Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') Load number (Btuhlft'-"F (Btuh/ftp or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S j Heat I Cool j Gross N/P/S j Heat I Cool 6 12C-0sw 6.091 n 3.32 - 2.64 38 38 128 102 0 0 0 0 10D-v 0.750 n 27.38 16.01 0 0 0 0 0 0 0 0 2glazing,drlow-e 0.390 - n_ 14.23 - 12.01 - 0_ -- - 0 0 _ 0 _ 0 _ 0 -_, 0 _ 0 V�! 12C-Osw 0.091 n 3.32 2.64 0 0 0 0 0 0 0 0 1 1 L -G 2 glazing,cir low-e 0.390 n 14.23 12.80 _ 0 0 0 0 0 0 0 0 12C-0sw 0.091 a 3.32 2.64 - 0 0 0 0 0 0 0 0 L�-CG 10D-v 0.750 a 27.38 18.01 0 0 0 0 0 0 0 0 2.glazing,Grlow-e 0.390 e_ 14.23 .-_,35.16 - 0 0 0 - - _ _ 0. _ __._.o 0 0- 0 W 12C-0sw 0.091 a 3.32 2.64 0 0 0 0 0 0 0 0 W 12C-0sw 0.091 s _ .3.32 L 2.64 ':0 __ %. -0 0 - 0 0 . 0 0 12C-0sw 0.091 s 3.32 2.64 98 89 297 236 0 0 0 0 2 glazing,dr low-e 0.390 s 14.23 14.80 4 4 59 62 0 0 0 0 2 glazing,Gr low-e _ 0.390 _s. 14.23 14.80 4 4 5.9 62 _ - _ 0 0 _ 0 0 W_ . . .12C-Osw 0.097 s- -, 3.32 s 2.64 0 0 0 12C-0sw 0.091 w 3.32 2.64 0 0 0 0 0 0 0 0 10D-v 0.750 w 27.38 18.01 0 0 0 0 0 0 0 0 2 glazinq,dr low-e 0.750 w 27.38 56.48 0 0 0 0- _ 6 0 _, 0 0_ 'P.:" Partition Wall- 0.101 3.70 1.94 0 0 0 0 0 0 0 0 11D0 0.390 n 14.23 13.28 __ 0.. 0 -0 -0 _._ -0 _. - 0 0 _0 C 16C-08ml ,. __ 0.026 - 0.95- _ 1.24 _. 0 0 0 0 0 0- 0 0 i{ 16X19-38ml 0.026 - 0.68 ;. 0.51 88 80 55 41 0 0 0 0 r--G Sky glazing;.small, 0.390 s. _ '14.23 Y .63.07 . 8 0 109 482 .0 - 0 F 22A-tpm 1.180 - 43.07 0.00 135 11 474 0 30 0 0 0 6 c)AED excursion 1 -341 1 1 10 Envelope loss/gain 1180 949 1 1 0 0 12 a) Infiltration 480 164 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1660 1114 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1660 1114 0 0 15 Duct loads 17% 15% 290 162 -0% 0% 0 0 I Ai01 01 r required(dm) I I I Toal room load1953041 1275 531 I I 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A- wrlgt� oTt- 2017-Nov-2811:47:51 -- A-^-- Right-Suite@ Universal 2018 18.0.04 RSU25613 Page 4 Residence\Working Drawings\Toomer Residence.rup Calc=MJ8 Front Door faces: E 't P- wright:soft• Right-J® Worksheet Job: ToomerResidence Entire House Date: Nov 28,2017 By: Nate Paslay ProCalcs, LLC P.O.Box 682032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 RTIN#0105474 1 Room name Master Bedroom Foyer 2 Exposed wall 24.0 ft 8.0 ft 3 Room height 7.8 it heat/cool 7.0 ft heat/cool 4 Room dimensions 14.0 x 17.0 ft 8.0 x 5.5 ft 5 Room area 238.0 ft2 44.0 ft' Ty Construction U-value Or HTM Area (f t') Load Area If t2) Load number (Btuh/ft'-°F I (Btuh/fv) I or perimeter (ft) I (Bluh) I or perimeter (ft) I (Btuh) Heat Cool Gross NIP/S Heat Cool Gross WP/S Hetj Cool 6 W12C-0sw 0.091 n 3.32 2.64 78 47 157 125 0 0 0 0 10D-v 0.750 n 27.38 16.01 310 852 498 0 0 0 0 _,-=-G 2glazing, 1rlow-e _ 0_.390 n_ 14.23 12.01 . 0 _0 0 0 ,. _ _ 0 _ 0,_ 0' _ 0 12C-0sw 0.091 n 3.32 2.64 0 0 0 0 0 0 0 0 11 !---G 2 glazing,dr low-e, 0.390 n 14.23 12.80 _ 0 0 0 _ 0 0 0 0 _ 0 1�1 12C-Osw 0.091 a 3.32 - 2.64 0 , 0 0 0 - 56 16 53 42 �C 1013-v 0.750 e - 27.38 18.01 - 0 0 0 0 40 40 1095 720 L-G 2 glazing,or lower .- 0.390 e_ .,- 14.23 35.16 _ 0 0 0 0 0 0 0 0 W-... .. 12C-0sw - ._ _.. ._ 0.091 .,e 3.32 2.64 . 0 .. 0 -. 0 0 0 0 0 0 W,' 12C-0sw 0.091 - s __. ..3.32 ..' .2.64 _ ..:__.0 _.. ..: =0 a-0. .. 0 -..',_ 0 . 0:-. 0 0 12C-0sw 0.091 s 3.32 2.64 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.390 s 14.23 14.80 0 0 0 0 0 0 0 0 t���-----((GGG 2 glazing,dr low-e 0.390 _s 14.23 14.80_ 0 0 _ 0 0 _ 0 0 0 0 W..: .: 12C;Osw... :; .. .0.091' s. i .3.32 2.64 0-. 0 0 0 0 _0 . 0: -0 12C-0sw 0.091 w 3.32 2.64 110 32 105 84 0 0 0 0 1013-v 0.750 w 27.38 18.01 0 0 0 0 0 0 0 0 2 glazinq,dr low-e _ 0.750 w 27.38 - 56.48 -- 78 0 2135 4406 _ _ 0 - _ 0 - 0 0 .P_ Partition Wall, 0.101 3.70 1.94 0 0 - -0 0 0 0 0 0 11DO_. A.390 n 14.23.`_'13.28 10" -.0 0 0 0 0__ _ _ _0 :.0 C 16C-38ml _ 0.026 - 0.95 _. 1.24 _ _ - 42 42 .-40 52 ._ _ 0 0 _ 0 - 0 16X19-38ml 0.026 - 0.68 0.51 0 0 0 - 0 0 0 0 0 Sky glazing,.small, -0.390 s 14.23 .63.07 0 -0 „_.q-_0 0 ._ _: 0.__._ 0. 0 0 F 22A-tpm 1.180 - 43.07 0.00 238 24 1034 0 44 8 345 0 61 c)AED excursion 1 1 1736 -24 Envelope loss/gain 1 4322 6901 1 1 1493 738 12 a) Infiltration 663 227 198 68 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal(lines 6 to 13) 4986 7128 1690 806 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4986 7128 1690 806 15 Dud loads -0% 0% 0 0 -0% 0% 0 0 I I Air required(dm) I I I l room load 49871 72981 I I 16 0 1 0 606 341 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r++- wrlgf�tcoTt 2017-Nov-2811:47:51 ^-- ^^ Right-Suite®Universal 2018 18.0.04 RSU25613 Page Residence\Working Drawings\Toomer Residence.rup Calc=MJ8 Front Door faces: E +�-wrightsoft• Right-J® Worksheet Job: ToomerResidence Entire House Date: Nov 28,2017 ProCalcs, LLC By: Nate Paslay P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-862-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 RTIN#0105474 1 Room name Living Room 2 Exposed wall 70.0 ft 3 Room height 12.8 ft heaticool 4 Room dimensions 1.0 x 446.0 ft 5 Room area 446.0 ft' Ty Construction U-value Or I HTM I Area (f t') I Load I Area I Load 'F number (Btuh/ft'- (Bt uh/ft') or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 12C-Osw 0.091 n 3.32 2.64 479 467 1551 1235 1OD-v 0.750 n 27.38 " 16.01 0 0 0 0 2 glazing,Gr.low-e 0.390 n-- - 14.23 _ 12.01 _ - 12 _ _0 --171 144 �1 12C-Osw 0.091 n 3.32 2.64 0 0 0 0 11 �--G 2 glazing,dr low-e 0.390 n 14.23 12.80 0 0 0 0 12C-0sw 0:091 a 3.32 2.64 131 86 287 228 1OD-v0.750 a 27.38 18.01 0 0 - 0 0 2 glazing,dr lower 0.390 _ e 14.23 _35.16 _ 45 -0 641 1582 W 126-0sw 0.091 a 3.32 2.64W' _ 0 0 0 0 -0sw_12C -:. ' -- - 0.091 .. s 3.32 . ::...2.64_. _ _ 0- 0 0 0 yL12C-0sw 0.091 s 3.32 2.64 148 148 492 392 2 glazing,dr low-e 0.390 s 14.23 14.80 0 0 0 0 2 glazing,dr low-e 0.390 s 14.23 _ 14.80 0 0 0 0 _W. _ 12CGOsw _.<'i' 0:091 ..s- 3.32. :2.64 `.: 0 0 0 p 12C-Osw 0.091 w 3.32 2.64 135 104 344 274 10D-v 0.750 w 27.38 18.01 31 31 852 560 2 clazina.dr low-e 0.750 w 27.38 56.48 _ 0 0 0 0 P Partition Wall , " ' 0.101 - 3.70 1.94 0 " 0 0 0 D 11130 . -:. _ 0.390 _ n __ 14.23 __- 13.28 0_ -0 0 0 C 16C-38ml 0.026 - 0.95 1.24 254 254 241 314 16X19-38m1 0.026 - 0.68 0.51 0 - -0 0 0 .Sky glazing,`small, -0.390 s 14.23 63.07 _ 0 _ 0 0 0 . F 22A-tpm 1.180 - 43.07 0.00 446 70 3015 0 61 c)AED excursion 1 -240 Envelope loss/gain 7593 4489 1 1 12 a) Infiltration 3152 1079 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 4 920 Appliances/other 1400 Subtotal(lines 6 to 13) 10745 7888 Less external load - 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 10745 7888 15 Dud loads -0% 0% 0 0 TotaAirrelqured(dm) I I I room load 101 8I 7330 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -a41- 2017-Nov-2811:47:51 ,45& -� Right-Suite®Universal 2018 113.0.04 RSU25613 Page Residence\Working Drawings\Toomer Residence.rup Calc=MJB Front Door faces: E Duct System Summary Job: Toomer Residence - - wri�t�tsafta Date: Nov 28,2017 Entire House By: Nate Paslay PrOCaICS, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 R-I-IN#0105474 Project • • For: Toomer Residence 410 Garden Lane,Atlantic Beach, FL 32233 Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.31 in H2O 0.31 in H2O Available static pressure 0.29 in H2O 0.29 in H2O Supply/return available pressure 0.145/0.145 in H2O 0.145/0.145 in H2O Lowest friction rate 0.124 in/100ft 0.124 in/100ft Actual air flow 503 cfm 1007 cfm Total effective length(TEL) 234 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat[ Ln(ft) Ln(ft) Trunk Dining Room C 485 0 20 0 0 Ox 0 VIFx 0 0 Foyer C 806 30 34 0 0 Ox 0 VIFx 0 0 Hers C 1451 50 61 0.124 5.0 Ox 0 VIFx 54.5 180.0 st2 I(itchen C 3765 79 157 0 0 Ox 0 VIFx 0 0 Laundry h 843 15 14 0.134 4.0 Ox 0 V[Fx 41.6 175.0 st2 Living Room c 3944 94 165 0 0 Ox 0 VIFx 0 0 Living Room-A C 3944 94 165 0 0 Ox 0 VIFx 0 0 Master Bathroom C 1275 34 53 0.133 5.0 0x0 VIFx 42.4 175.0 st2 Master Bedroom C 3564 44 149 0 0 Ox 0 VIFx 0 0 Master Bedroom-A C 3564 44 149 0 0 Ox 0 VIFx 0 0 Office C 972 20 41 0.131 4.0 Ox 0 VIFx 47.0 175.0 st2 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 120 168 0.124 758 7.1 8 x 4 RectFbg st2 Peak AVF 120 168 0.124 630 7.0 0 x 0 VinlFlx st1 Bold,dallc values have been manually overridden - - wvrights®ft- 2017-Nov-2811:47:52 Right-Suite®Universal 2018 18.0.04 RSU25613 Pagel ACCX ...Residence%Worldng Drawings%Toomer Residence.rup Calc=MJ8 Front Door faces: E Return Branch Detail Table Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 503 1007 0 0 0 0 Ox 0 VIFx - - wrightsoft- 2017-Nov-2811:47:52 �� «• ..•. _ . , Right-Suite®Universal 2018 18.0.04 RSU25613 Paget iC+�1 ...ResidenceMorking DrawingsWoomer Residence.rup Calc=MJ8 Front Door faces: E Static Pressure and Friction Rate Job: Toomer Residence wrightsoft' Date: Nov 28,2017 Entire House By: Nate Paslay ProCalcs, LLC P.O.Box 882032,Port Saint Lucie,FL 34988 Phone:772-882-5700 Email:tom@procalcs.net Web:www.ProCalcs.Net License:CAC1815254 RTIN#0105474 Project • • For: Toomer Residence 410 Garden Lane,Atlantic Beach, FL 32233 AvailablePressure Heating Cooling (in H2O) (in H2O) External static pressure 0.60 0.60 Pressure losses Coil 0.07 0.07 Heat exchanger 0 0 Supply diffusers 0.03 0.02 Return grilles 0.03 0.02 Filter 0.15 0.1E Humidifier 0 0 Balancing damper 0.03 0.02 Other device 0 0 Available static pressure 0.29 0.29 Total • Supply Return (ft) (ft) Measured length of run-out 19 0 Measured length of trunk 35 0 Equivalent length of fittings 180 0 Total length 234 0 Total effective length 234 Friction - Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.124 OK 0.124 OK Return Ducts 0.124 OK 0.124 OK Fitting Equivalent LengthDetails Supply 4W=35, 11 A=20, 11 G=5, 11 G=5, 11 G=5, 11 G=5,9K=65, 11 G=5, 1 C=35:TotalEL=180 Return TotalEL=O - - wrightsoft 2017-Nov-2811:47:52 .,.� Right-Suite®Universal 2018 18.0.04 RSU25613 Pagel ACCA ...Residence\Working Drawings\Toomer Residence.rup Calc=MJB Front Door faces: E a � ------------- 9i ii qe �, 9e ri � Q Id I I I e e�,u N p Toomer Residence ' L9 � 11 410 Garden Lane n Atlantic Beach,FL 32233 9 ,� MAP SHOWING SURVEY OF LOT 4, SELVA MARINA GARDEN TWO, AS RECORDED IN PLAT BOOK 38, PAGE 39, OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. a 0 �x p to z,0 4p m ' SCALE: 1" = 20' R 1 �o ' a LOT 5 Q � I t t FOUND -IRON 'S86-17'40"C'6115.29' FIELD) o ZQ' 9' PIPE,)40 S855 ,I q 6'WOOD FENCE ;5.14• ' Ld z 3'1• iV 1.7' '� ' FOUND 1/2'IRON Ld nj o PIPE,NO CAP 7 Q a C) Z4 0 4 DEC1Dom' fj obi Fl �� 2.4'WCO 8.4'� WOODELOOR M 1V QfCK WAD 10-3. 0 a+w N� ,�"/y v n AN PORCH 3',n (L TORY (Ln�i g a.s• TWO SRES DE NE NAN AND 19.9' a O Q 18. 410 00 7• W I 2 a wooD * Q 12.3' fO DECK pOH tTE 0 0 ca WOOD (n.. /�i Q' m A/C PAD 5 -� AVER6 18'7 0.5' 36.J' 0. . LL ��y�OOB-FEC 'p I� 9.f /!/ a - r 6'W000 FENCE 1.1' 19.8' FOUND 1/2'IRON O FOUND CONCRETE S8 6"W 1 2 ,00, PIPE,ILLEGIBLE MONUMENT II' (P.RM .) � v IL NO IDENTIFICATION 120.15' FIELD iI' CL so LOT 14 (0 Z LOT 13 m o LO 00 X O Ci- SELVA MARINA GARDEN PLAT BOOK 37, PAGE 84 iti�oo/r' RIGHT OF WAY 20 th STREET NOTES: THIS IS A BOUNDARY SURVEY. BEARINGS ARE BASED ON THE SOUTH LINE OF LOT 4, BEING SOUTH 89'08'46" WEST, PER PLAT. THERE ARE NO BUILDING RESTRICTION LINES BY PLAT. THE PROPERTY SHOWN HEREON LIES IN FLOOD ZONE "X' (AREA OUTSIDE 0.2% ANNUAL CHANCE THIS SURVEY WAS MADE FOR THE BENEFIT OF FLOODPLAIN) AS WELL AS CAN BE DETERMINED CURTIS W. AND MICHELE M. TOOMER. FROM THE FLOOD INSURANCE RATE MAP NUMBER 12031CO407H REVISED JUNE 3, 2013 FOR THE CITY OF ATLANTIC BEACH, DUVAL COUNTY, FLORIDA. "NOT VAUD WITHOUT THE SIGNATURE AND DONN W. BOATWRIGHT, P.S.M. THE ORIGINAL RAISED SEAL OF A FLORIDA FLORIDA LIC. SURVEYOR and MAPPER No. LS 3295 LICENSED SURVEYOR AND MAPPER." BOUNDARY SURVEY RECHECK:SEPTEMBER 28,2017 FLORIDA LIC. SURVEYING &MAPPING BUSINESS No. U3 3672 CHECKED BY: BOATWRIGHT LAND SURVEYORS, INC. DRAWN BY: DAF FILE: 2017-1314 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 SHEET 1 OF 1 REF:98-483 MAP SHOWING SURVEY OF LOT 4, SELVA MARINA GARDEN TWO, AS RECORDED IN PLAT BOOK 38, PAGE 39, OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. e a O �Y Q 10 2,0 40 g m i SCALE 1" = 20' X 14 m0 0 a LOT 5 i ¢ 1111 t r FOUND 1/2-IRON (S86*21'55"E ' 20'f 9't PIPE,NO CAP ZS86,1 7,40"E 115.29' FIELD) I 6'WOOD FENCE 115.14' , bi w Z3'1fV 1.7' FOUND 1/2'IRON J N o 4 NO CAP z Q 0' ^Q 6 V P O O 3 li� WOOp m 36-3' Q ' (p DECK � � 0� ami FL 2.4zNG- ' 8.4'� 2tVN0 DEC M j C A �- r m 4J �Lca _ Q ti W d' WOOD 6 10.3' — O 7 W N ^ �' POh x LL o rn w = Two STORY 36.6' 17 � O 49, eESIDENCE N0.410 UCCO 19'9 1'- 0 e 00 m Q C7 12.3' DECK N CONCRETE Q O WOOD ORNEiygy (n A/C PAD 36.3' 0.$' PAVERS 18't .5' 6'W000 FENCE 9'f , 6'W000 FENCE 1.1' 1g•6' FOUND 1/2'IRON O FOUND CONCRETE S89.o8 6"W 1 20,00, PIPE,ILLEGIBLE :MONUMENT(P.R.M.) m (120.15' FIELD) I �- D_ I NO IDENTIFICATION £ a I O O J Z , LOT 14 a i LOT 13 �m , O 0 I � a SELVA MARINA GARDEN < PLAT BOOK 37, PAGE 84 0 �o RIGHT OF WAY 20 th STREET THIS NOTESIS A BOUNDARY SURVEY. BEARINGS ARE BASED ON THE SOUTH LINE OF LOT 4, BEING SOUTH 89'08'46" WEST, PER PLAT. THERE ARE NO BUILDING RESTRICTION LINES BY PLAT. THE PROPERTY SHOWN HEREON LIES IN FLOOD ZONE "X" (AREA OUTSIDE 0.2% ANNUAL CHANCE THIS SURVEY WAS MADE FOR THE BENEFIT OF FLOODPLAIN) AS WELL AS CAN BE DETERMINED CURTIS W. AND MICHELE M. TOOMER. FROM THE FLOOD INSURANCE RATE MAP NUMBER 12031CO407H REVISED JUNE 3, 2013 FOR THE CITY OF ATLANTIC BEACH, DUVAL COUNTY, FLORIDA. "NOT VALID WITHOUT THE SIGNATURE AND DONN W. BOATWRIGHT, P.S.M. THE ORIGINAL RAISED SEAL OF A FLORIDA FLORIDA UC. SURVEYOR and MAPPER No. LS 3295 LICENSED SURVEYOR AND MAPPER." BOUNDARY SURVEY RECHECK SEPTEMBER 28,2017 FLORIDA LIC. SURVEYING &MAPPING BUSINESS No. LB 3672 CHECKED BY' DATE: DRAWN BY: DAF BOATWRIGHT LAND SURVEYORS, INC. JULY 9. 1998 FILE: 2017-1314 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 SHEET 1 OF_ REF:88-483 MAP SHOWING SURVEY OF LOT 4, SELVA MARINA GARDEN TWO, AS RECORDED IN PLAT BOOK 38, PAGE 39, OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. 0 0 W r � q to zo ao Q 2 �m � SCALE: t^ = 20' X a I Lor s i Q 'FOUND 1/2-IRON p(SB6'21'55"E C 115.29' FIELD) I 20'f 9't PIPE.NO CAP /SCJ6*17'40 E D'WOOD FENCE �� 115.14' w W I' 2 1y 1.7' FOUND 1/2'IRON J nj O PIPE,NO CAP �j Q a O La �—u W O 3 /i W000 iD 36.3 ip 0 ' fQ DECK Q^ fj \��Oy�1��. 2.4' .0 2ND FLOOR IMI Lr W �- i B&CO}„ 8.4' W00—RICK If)G: Q W WOOD 10.3•\\` W!f- 51Lp O N v ^ AN PORCH LL3 0 FRAME 36.6' M Q TWO ORY ' I a ry 3 4 9, SRESIDENCE NON 41 p UCCO 18.9' qD c W i'-- 187- 111 cO 0 r Z 12.3' m ECK ° 60(O QRlzWw O C1 W000 < A/C PAD 36.3' 0.5' PAPERS 18't 5 B.WOOD FENCE 9't s fi', h 6'WOOD FENCE 1.1' 79.8' FOUND 1/2"IRON O FOUND CON RETE S89�o8 6 YY 12O,OV� PIPE,ILLEGIBLE n` MONUMENT C .) mFIELD) ' �•, O IND NO IDENTIFICATIONATIONATON £ (120.15' ¢ I V F g O WY LOT 14 � i LOT 13 C) i I ro a. SELVA MARINA GARDEN 4 PLAT BOOK 37, PAGE 84 �YL o RIGHT OF WAY 20 th STREET NOTES: THIS IS A BOUNDARY SURVEY. BEARINGS ARE BASED ON THE SOUTH LINE OF LOT 4, BEING SOUTH 89'08'46" WEST, PER PLAT. THERE ARE NO BUILDING RESTRICTION LINES BY PLAT. THE PROPERTY SHOWN HEREON LIES IN FLOOD ZONE "X" (AREA OUTSIDE 0.2% ANNUAL CHANCE THIS SURVEY WAS MADE FOR THE BENEFIT OF FLOODPLAIN) AS WELL AS CAN BE DETERMINED CURTIS W. AND MICHELE M. TOOMER. FROM THE FLOOD INSURANCE RATE MAP NUMBER 12031CO407H REVISED JUNE 3, 2013 FOR THE CITY OF ATLANTIC BEACH, DUVAL COUNTY, FLORIDA. "NOT VALID WITHOUT THE SIGNATURE AND DONN W. BOATWRIGHT, P.S.M. THE ORIGINAL RAISED SEAL OF A FLORIDA FLORIDA UC. SURVEYOR and MAPPER No. LS 3295 LICENSED SURVEYOR AND MAPPER." BOUNDARY SURVEY RECHECK:SEPR]ABER 28,2017 FLORIDA UC. SURVEYING &MAPPING BUSINESS No. LB 3672 CHECKED BY: DATE: DRAWN BY: DAF BOATWRIGHT LAND SURVEYORS, INC. JULY 9, 1998 FILE: 2017-1314 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 SHEET 1 OF 1 REF:98-483 TO: Scott Williams,Director City of Atlantic Beach,Public Works FROM: James Kelley Elite Custom Homes &Renovations Inc. DATE: 11/30/17 SUBJECT: Construction Management Plan 410 Garden Lane Atlantic Beach,FL 1) Parking will be on the property as noted on the Construction Site Management Plan(CSMP). 2) There will not be a construction trailer on this site. The unloading and loading area and material storage are identified on CSMP. 3) Location of chemical toilet is identified on CSMP and will be located on owner's property with door facing construction project. 4) Dumpster location is on CSMP and an approved dumpster company will be used. 5) Traffic control pattern is shown on the plan with entrance to property. Adequate parking is available on the street. 6) The site will be cleaned and picked up for all debris including construction material and all other trash regularly. 7) Right of way will be restored to its original condition. 8) Any utility cuts in road made by contractor with be overlaid 10 feet in each direction from the center of the cut. TO: Scott Williams,Director City of Atlantic Beach, Public Works FROM: James Kelley Elite Custom Homes &Renovations Inc. DATE: 11/30/17 SUBJECT: Erosion& Sediment Control Plan 410 Garden Lane Atlantic Beach, FL 1) Erosion and Sediment Control will be maintained throughout construction. There will be a silt fence surrounding the project. Inspection by Public Works of Erosion and Sediment Control will be done prior to commencing work. All siltation will remain on-site during construction.