1545 MAIN ST - PERMIT 16-COTH-2320 DWGSAPPROVALS LOCATION MAP INDEX OF DRAWINGS RF ENGINEER DATE .a CONSTRUCTION DATE a � SITE ACQUISITION DATE DRIVING DIRECTIONS ZONING DATE MI GENERAL NOTES, ABBREVIATIONS EXPOSURE= C IMPORTANCE FACTOR= 1.0 8. AT EXIT 49, TAKE RAMP RIGHT FOR `v 1. DEPART GREENWOOD BLVD TOWARD JOHNS BLUFF RD TOWARD ST JOHN c; EXCHANGE PL 0.2 MI BLUFF RD 1.0 MI 2. TURN RIGHT ONTO EXCHANGE PL 0.3 MI 9 •w» p % TURN LEFT ONTO LAKE EMMA RD 0.7 MI z a 4. TURN LEFT ONTO W LAKE MARY BLVD 0.1 10. KEEP RIGHT ONTO ATLANTIC BLVD C AN -1 JubonrMN _ ; SITE LOCATION � o � Y ,a� TAKE RAMP RIGHT FOR I-4 EAST TOWARD 100 FT DAYTONA BEACH 33.4 MI 12. BEAR RIGHT ONTO SR -AIA N / MA rn 6. TAKE RAMP LEFT FOR 1-95 NORTH RD 0.8 MI w TOWARD JACKSONVILLE 76.8 MI 13. TURN LEFT ONTO LEVY RD 0.3 MI a 7. AT EXIT 337, TAKE RAMP RIGHT FOR M 1-295 NORTH TOWARD JAX BEACHES 12.1 ARRIVE AT 407 LEVY RD, ATLANTIC BEA ASSOCIATED WORK. 32233 -c &A N3 _. -tac, r � VICINITY MAP APPROVALS MI BLVD I2R NETWORK PROPERTY OWNER DATE INDEX OF DRAWINGS RF ENGINEER DATE .a CONSTRUCTION DATE T-1 SITE ACQUISITION DATE DRIVING DIRECTIONS ZONING DATE MI BLVD I2R NETWORK UAIL INDEX OF DRAWINGS - FLORIDA BUILDING CODE 5th EDITION (2014) ANSI/EIA/TIA-222-G (ALLOWED PER EXEMPTION #5 OF 1609.1.1) ASCE 7-10 .a DATE T-1 o DRIVING DIRECTIONS o FROM AT&T OFFICES IN LAKE MARY: MI GENERAL NOTES, ABBREVIATIONS EXPOSURE= C IMPORTANCE FACTOR= 1.0 8. AT EXIT 49, TAKE RAMP RIGHT FOR `v 1. DEPART GREENWOOD BLVD TOWARD JOHNS BLUFF RD TOWARD ST JOHN - FLORIDA FIRE PREVENTION CODE 5th EDITION EXCHANGE PL 0.2 MI BLUFF RD 1.0 MI 2. TURN RIGHT ONTO EXCHANGE PL 0.3 MI 9. TURN RIGHT ONTO SR -10 E / ATL 3. TURN LEFT ONTO LAKE EMMA RD 0.7 MI BLVD 6.1 MI 4. TURN LEFT ONTO W LAKE MARY BLVD 0.1 10. KEEP RIGHT ONTO ATLANTIC BLVD C AN -1 MI 11. TURN LEFT ONTO SR-A1A / FLORI[ v 5. TAKE RAMP RIGHT FOR I-4 EAST TOWARD 100 FT DAYTONA BEACH 33.4 MI 12. BEAR RIGHT ONTO SR -AIA N / MA rn 6. TAKE RAMP LEFT FOR 1-95 NORTH RD 0.8 MI w TOWARD JACKSONVILLE 76.8 MI 13. TURN LEFT ONTO LEVY RD 0.3 MI a 7. AT EXIT 337, TAKE RAMP RIGHT FOR M 1-295 NORTH TOWARD JAX BEACHES 12.1 ARRIVE AT 407 LEVY RD, ATLANTIC BEA ASSOCIATED WORK. 32233 MI BLVD I2R NETWORK UAIL INDEX OF DRAWINGS - FLORIDA BUILDING CODE 5th EDITION (2014) ANSI/EIA/TIA-222-G (ALLOWED PER EXEMPTION #5 OF 1609.1.1) ASCE 7-10 OPERATIONS DATE T-1 TITLE SHEET CONTRACTOR DATE PROJECT SUMMARY SITE NAME: FA SITE NUMBER: PARCEL: COUNTY: JURISDICTION: SITE COORDINATES: STRUCTURE TYPE: PROJECT INITATIVE: TOWER HEIGHT: ANTENNA C.L. HEIGHT J020-MAYPORT 10020470 172325-0000 DUVAL CITY OF ATLANTIC BEACH N 30' 20' 13.99" W 81' 25' 11.32" SELF SUPPORT TOWER WCS FILTER 193'-0" AGL 190'-0" AGL LEGAL DESCRIPTION 1545 MAIN ST 17 -2S -29E 5.71 PT GOVT LOT 4 RECD 0/R 11544-628 BEING PARCEL 3 PROJECT REFERENCES 1. THESE PLANS WERE COMPLETED PER WCS FILTER RFDS V2.00 DATED 04/25/16. CONTRACTOR SHALL REQUEST CURRENT RFDS & WORKBOOK FROM CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. J020-MAYPORT FA #10020470 CROWN CASTLE BU #812565 1545 MAIN STREET ATLANTIC BEACH, FL 32233 TENANT IMPROVEMENT - WCS FILTER DESIGN CRITERIA '0`" aEc INDEX OF DRAWINGS - FLORIDA BUILDING CODE 5th EDITION (2014) ANSI/EIA/TIA-222-G (ALLOWED PER EXEMPTION #5 OF 1609.1.1) ASCE 7-10 SHT. NO DESCRIPTION T-1 TITLE SHEET ULTIMATE WIND SPEED = 130 MPH BASIC WIND SPEED = 101 MPH (NOMINAL) RISK CATEGORY= II GN -1 GENERAL NOTES, ABBREVIATIONS EXPOSURE= C IMPORTANCE FACTOR= 1.0 ARCHITECTURAL /CIVIL PLANS C-1 SITE PLAN - NATIONAL ELECTRICAL CODE, 2011 EDITION (NEPA 70-2011) - FLORIDA FIRE PREVENTION CODE 5th EDITION STRUCTURAL PLANS - CONTRACTOR TO CONFIRM THAT THE SITE IS COMPLIANT WITH RF WARNING SIGNAGE & EMERGENCY SIGNAGE AS REQUIRED BY THE FEDERAL GUIDELINES CONTAINED WITH OET 65 BULLETIN & IS S-1 TOWER ELEVATION AND ANTENNA ORIENTATION -2 MISCELLANEOUS DETAILS AS PER AT&T GUIDELINES CONSTRUCTION NOTES ANTENNA SCHEDULE 1. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING AN -1 ANTENNA SCHEDULE DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. �+ 2. CONTRACTOR SHALL NOTIFY OWNER FOR ACCESS TO SITE.C C 3. THIS PROJECT CONSISTS OF THE INSTALLATION OF: (3) NEW RRUS-32 B2, (2) NEW FILTERS AND ALL ASSOCIATED WORK. ref -c &A N3 _. -tac, CONTACTS '0`" aEc APPLICANT: AT&T MOBILITY 1101 GREENWOOD BLVD. LAKE MARY, FL 32746 TOWER OWNER: CROWN CASTLE 4511 NORTH HIMES AVE SUITE 210 TAMPA, FL 33614 ENGINEER: USA ENGINEERING INC. 2130 ASHLEY OAKS CIR. SUITE 102 WESLEY CHAPEL, FL 33544 CONTACT: MARC MAIER, P.E. PHONE: 813-994-0365 EO 0 06/03/16 FINAL CDs ISSUED 1 09/22/16 REVISED ADDRESS 2 3 4 PROJECT INFORMATION NO. 1. THIS IS AN UNMANNED FACILITY AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. 2. AT&T CERTIFIES THAT THIS EQUIPMENT FACILITY WILL BE SERVICED ONLY BY AT&T EMPL0 ES UBCONTRACTORS AND THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED FACILITY WILL BE FREQUENTED ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES ONLY. 3. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. A' 4. NO WASTEWATER WILL BE GENERATED AT THIS LOCATION. ' 5. NO SOLID WASTE WILL BE GENERATED AT THIS LOCATION. REV DATE DESCRIPTION A 05/24/16 PRELIMINARY CDs REV "A" 0 06/03/16 FINAL CDs ISSUED 1 09/22/16 REVISED ADDRESS 2 3 4 5 6 7 8 9 GOFF PROJECT NO.: 01 81 6000-1 52 DRAWN BY: CHECKED BY: SS MM at&t 1101 GREENWOOD BLVD LAKE MARY, FL 32746 FAX (407) 771-1398 smarth. 1997 ANNAPOLIS EXCHANGE PKWY. SUITE 200 ANNAPOLIS, MD 21401 PREPARED BY: 9IENGINEERING 2130 ASHLEY OAKS CIRCLE SUITE 102 WESLEY CHAPEL, FL 33544 (813) 9 FL COA#31705 Prrr®���,¢�`� No 72513 TATE OF o14 s� O R .� N SEPTEMBER 22.2016 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 JOZo-MAYPORT FA #10020470 1545 MAIN STREET TLANTIC BEACH, FL 32233 SHEET DESCRIPTION TITLE SHEET SHEET NUMBER T-1 GENERAL NOTES: 1. ALL REFERENCES TO OWNER HEREIN SHALL BE CONSTRUED TO MEAN FST&T OR IT'S DESIGNATED REPRESENTATIVE. 2. ALL WORK PRESENTED ON THESE DRAWINGS MUST BE COMPLETED BY E CONTRACTOR UNLESS NOTED OTHERWISE. THE CONTRACTOR MUST HA CONSIDERABLE EXPERIENCE IN PERFORMANCE OF WORK SIMILAR TO THAT DESCRIBED HEREIN. BY ACCEPTANCE OF THIS ASSIGNMENT, THE CONTRACTOR IS ATTESTING THAT HE DOES HAVE SUFFICIENT EXPERIENCE AND ABILITY, HAT HE IS KNOWLEDGEABLE OF THE WORK TO BE PERFORMED AND THAT HE IS F ROPERLY LICENSED AND PROPERLY REGISTERED TO DO THIS WORK IN THE STAI AND/OR COUNTY IN WHICH IT IS TO BE PERFORMED. 3. UNLESS SHOWN OR NOTED OTHERWISE ON THE CONTRACT DRAWINGS, OR IN THE SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY TO THE MATERIALS LISTED HEREIN, AND TO THE PROCEDURES TO BE USED ON THIS PROJECT. 06/03/16 FINAL CDs ISSUED 4. ALL HARDWARE ASSEMBLY MANUFACTURER'S INSTRUCTIONS SHALL BE FOLLOWED 09/22/16 REVISED ADDRESS EXACTLY AND SHALL SUPERCEDE ANY CONFLICTING NOTES ENCLOSED IEREIN. 5. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECT10 PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE STRUCTURE AND ITS COMPONENT PARTS DURING ERECTION AND/OR FIELD MODIFICATIONS. HIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER TEMP RARY BRACING, GUYS OR TIE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER THE COMPLETION OF THE PROJECT. 6. ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS SHOWN ON T IIE DRAWINGS SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE TE -STING AGENCY PRIOR TO BEGINNING ANY MATERIALS ORDERING, FABRICATION OR CONSTRUCTION WORK ON THIS PROJECT. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND THE 0 NER'S ENGINEER. THE DISCREPANCIES MUST BE RESOLVED BEFORE THE CON RACTOR IS TO PROCEED WITH THE WORK. THE CONTRACT DOCUMENTS DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AN DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUClION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY THE OWNER AND/OR THE ENGINEER SHALL NOT INCLUDE' INSPECTION OF THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES. 7. ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW AND OF QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE CONTRACT DOCUMENTS. ANY AND ALL SUBSTITUTIONS MUST BE PI APPROVED AND AUTHORIZED IN WRITING BY THE OWNER AND ENGIP INSTALLATION. THE CONTRACTOR SHALL FURNISH SATISFACTORY EVIC THE KIND AND QUALITY OF THE MATERIALS AND EQUIPMENT BEING 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAININ( SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTI THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT PROJECT AND RELATED WORK COMPLIES WITH ALL APPLICABLE LOCAL AND FEDERAL SAFETY CODES AND REGULATIONS GOVERNING THIS WO 9. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST THE LOCAL BUILDING CODE. 10. ALL PROPOSED CELLULAR EQUIPMENT AND FIXTURES SHALL BE FU OWNER FOR INSTALLATION BY THE CONTRACTOR, UNLESS SPECIFICF OTHERWISE HEREIN. 11. ACCESS TO THE PROPOSED WORK SITE MAY BE RESTRICTED. THE SHALL COORDINATE INTENDED CONSTRUCTION ACTIVITY, INCLUDING SCHEDULE AND MATERIALS ACCESS, WITH THE RESIDENT LEASING APPROVAL. 3. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIEFY (AWS) D.1.1/D1.1M:2010. STRUCTURAL WELDING CODE-STLEL WELD ELECTRODES SHALL 4. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND BE E70XX. CONDUCTORS. USE STAINLESS STEEL HARDWARE THROUGHOUT. 4. ALL COAXIAL CABLE CONNECTORS AND TRANSMITTER EQUIPMENT SHALL BE AS SPECIFIED BY THE OWNER AND IS NOT INCLUDED IN THESE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL FURNISH ALI CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE STAINLESS STEEL. 5. ALL REINFORCING STEEL SHALL CONFORM TO ASTM 615 GRADE 60, DEFORMED BILLET STEEL BARS. WELDED WIRE FABRIC REINFORCING SHALL CONFORM TO ASTM A185. 6. THE FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE LATEST A.I.S.C. SPECIFICATIONS. 7. ALL CONNECTIONS NOT FULLY DETAILED ON THESE PLANS SHALL BE DETAILED BY THE STEEL FABRICATOR IN ACCORDANCE WITH A.I.S.C. SPECIFICATIONS. 8. HOT -DIP GALVANIZE ITEMS SPECIFIED TO BE ZINC -COATED, AFTER FABRICATION WHERE PRACTICAL. GALVANIZING: ASTM A 123, ASFM, A 153/A 153M OR ASTM A 653/A 653M, G90, AS APPLICABLE. 9. REPAIR DAMAGED SURFACES WITH GALVANIZING REPAIR METHOD AND PAINT CONFORMING TO ASTM A 780 OR BY APPLICATION OF STICK OR THICK PASTE MATERIAL SPECIFICALLY DESIGNED FOR REPAIR OF GALVANIZING. CLEAN AREAS TO BE REPAIRED, AND REMOVE SLAG FROM WELDS. HEAT SURFACES TO WHICH STICK OR PASTE MATERIAL IS APPLIED WITH A TORCH TO A TEMPERATURE SUFFICIENT TO MELT THE METALLICS. IN STICK OR PASTE, SPREAD MOLTEN MATERIAL UNIFORMLY OVER SURFACES TO BE COATED AND WIPE OFF EXCESS MATERIAL. 10. CONTRACTOR SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS/SPECIFICATIONS IF NO INFORMATION IS CONTAINED IN THESE PLANS OR IF THE MANUFACTURER'S SPECIFICATIONS ARE STRICTER. NOTE: REFER TO AT&T SPECIFICATIONS AS THE CONTROLLING STANDARD FOR PROPOSED CONSTRUCTION i THE :RLY PRIOR TO PERMITS: E AS TO ISTITUTED. 1. CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS FOR THIS PROJECT FROM ALL APPLICABLE GOVERNMENTAL AGENCIES. AND I WITH 2. ANY PERMITS WHICH MUST BE OBTAINED SHALL BE THE CONTRACTOR'S iIS RESPONSIBILITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ABIDING BY STATE, ALL CONDITIONS AND REQUIREMENTS OF THE PERMITS. 3. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES AND THE ACI 318-08, FION OF "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE". 4. THE CONTRACTOR SHALL NOTIFY THE APPLICABLE JURISDICTIONAL (STATE, COUNTY iED BY OR CITY) ENGINEER 24 HOURS PRIOR TO THE BEGINNING OF CONSTRUCTION. NOTED 5. ALL DIMENSIONS SHALL BE VERIFIED WITH THE PLANS (LATEST REVISION) PRIOR RACTOR TO COMMENCING CONSTRUCTION. NOTIFY THE OWNER IMMEDIATELY IF DISCREPANCIES ARE DISCOVERED. THE CONTRACTOR SHALL HAVE A SET OF FOR APPROVED PLANS AVAILABLE AT THE SITE AT ALL TIMES WHEN WORK IS BEING PERFORMED. A DESIGNATED RESPONSIBLE EMPLOYEE SHALL BE AVAILABLE FOR CONTACT BY GOVERNING AGENCY INSPECTORS. 12. PREFABRICATED BUILDING INSTALLATION SHALL BE IN ACCORDANCEV�IITH THE MANUFACTURER'S SPECIFICATIONS. II 1. STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE I.S.C. SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS- ALLOWABLE STIR SS DESIGN AND PLASTIC DESIGN INCLUDING THE COMMENTARY AND THE A.I.S.C. CODE OF STANDARD PRACTICE. 2. STRUCTURAL STEEL PLATES AND SHAPES SHALL CONFORM TOASTM 6. ALL STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53 GRADE B. L STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500 GRADE ALL STRUCTURAL STEEL COMPONENTS AND FABRICATED ASSEMBLIES SHAL BE HOT DIP GALVANIZED AFTER FABRICATION. M 1. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLES SHALL CONFORM TO ASTM A307 OR ASTM 36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM A325. FASTENERS SHALL BE 5/8" MIN. DIA. BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED FROM THE PLANE. ALL EXPOSED FASTENERS, NUTS, AND WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. ALL ANCHORS INTO CONCRETE SHALL BE STAINLESS STEEL. 2. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HARDWARE SHALL BE STAINLESS STEEL. 3. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY NORTH AND NOTIFY CONSULTANT OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. 5. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS. 6. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS TO BE A MIN. OF 8" RADIUS. 7. FOR GROUNDING TO BUILDING FRAME AND HATCH PLATE GROUND BARS, USE A TWO -BOLT HOLE NEPA DRILLED CONNECTOR SUCH AS T&B 32007 OR APPROVED EQUAL. 8. FOR ALL EXTERNAL GROUND CONNECTIONS, CLAMPS AND CADWELDS, APPLY A LIBERAL PROTECTIVE COATING OR AN ANTI -OXIDE COMPOUND SUCH AS 'NO -OXIDE A' BY DEARBORN CHEMICAL COMPANY. 9. REPAIR ALL METAL SURFACES THAT HAVE BEEN CUT OR DAMAGED BY REMOVING ANY EXISTING RUST AND APPLYING COLD GALVANIZATION. 10. ANTENNA CABLE LENGTHS HAVE BEEN DETERMINED BASED ON THESE PLANS. CABLE LENGTHS LISTED ARE APPROXIMATED AND ARE NOT INTENDED TO BE USED FOR FABRICATION. DUE TO FIELD CONDITIONS, ACTUAL CABLE LENGTHS VARY. CONTRACTOR MUST FIELD VERIFY ANTENNA CABLE LENGTHS PRIOR TO ORDER. REV DATE DESCRIPTION A 05/24/16 PRELIMINARY CDs REV 'A' 0 06/03/16 FINAL CDs ISSUED 1 09/22/16 REVISED ADDRESS 2 3 4 5 7 8 L96 GOFF PROJECT NO.: 01 81 6000-1 52 DRAWN BY: CHECKED BY: SS MM at&t 1101 GREENWOOD BLVD LAKE MARY, FL 32746 FAX (407) 771-1398 smartie 1997 ANNAPOLIS EXCHANGE PKWY. SUITE 200 ANNAPOLIS, MD 21401 PREPARED BY: IS (ENGINEERING 2130 ASHLEY OAKS CIRCLE SUITE 102 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 ' "tiNrolollik, w N0 725138. 1� j ST TE 01 A .: . Geos se SEPTEMBER 22, 2016 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 Jo2o-MAYPORT FA #10020470 1545 MAIN STREET 4TLANTIC BEACH, FL 32233 SHEET DESCRIPTION GENERAL NOTES, ABBREVIATIONS SHEET NUMBER GN -1 NOTES: 1. CONTRACTOR TO FILL ANY EXISTING GRAVEL AREAS THAT ARE DISTURBED DURING THE COURSE OF CONSTRUCTION, GRAVEL TO MATCH EXISTING. 2. THE CONTRACTOR TO ENSURE THAT NO DAMAGE OR DEBRIS OCCURS ON THE ADJACENT PROPERTIES. 3. THE CONTRACTOR SHALL SEED ALL DISTURBED AREAS WITH LOW MAINTENANCE NATIVE GRASS AND COVER WITH APPROVED STRAW. 4. CONTRACTOR SHALL PROVIDE ALL REQUIRED EROSION CONTROL TECHNIQUES AND BEST MANAGEMENT PRACTICES PER LOCAL AND AND STATE REQUIREMENTS AS APPLICABLE. 5. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY NORTH AND INFORM ARCHITECT/ENGINEER OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. THE CONTRACTOR MUST FIELD VERIFY ALL MEASUREMENTS AND FIELD CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. ONE CALL - DIAL 811 CALL 3 WORKING DAYS BEFORE YOU DIG 1-800-638-4097 97'-8" (COMPOUND AREA) 7'-10" 43'-9" 36'-7" 9'-7" N N 4'-0" 8'-O" CHAIN LINK FENCE W/3 UTILITY 3.-2„ STRANDS OF BARBED WIRE j FRAME UTILITY FRAME o w N T -MOBILE _ J� I I 15'-0"x30'-0" 3'-0" WORKING - AREA I CLEARANCE GENERATOR i (TYP) T -MOBILE 8'-O"x13'-0" I GPS PAD (TYP 4) iv o .I 4' 4'-6"x5'-2" cv SLED N T -MOBILE 3'-0"x 4'-0" CABINET PAD AT&T MOBILITY a 5'-6"x 1 1 '-0" a LEG A=60' Z PAD/GENERATOR o zoo ® ^� ^ a 193'-0" 4'-0" SID co ^ 27 _8 SELF SUPPORT PAD TOWER co 8' N / 1 I = N EXISTING AT&T ICE EQUIPMENT SHELTER BRIDGE 4'-0" (TYP) ~z FND PAD CLEARWIR > CORP 1 o (TYP 3) j 7'-0'x7'-0" GTW L AREA J (TYP 11) N o ® ® EXISTING AT&T WAVEGUIDE T io BRIDGE � I n 29'-10" 28'-5" 39'-4" 97'-8" SOUND AREA) SITE PLAN C-1 SCALE: 1" = 15' SCALE BASED ON 11"x17" ONLY GRAPHIC SCALE 0 7.5 15 30 (INS) TRUE NORTH REV DATE DESCRIPTION A 05/24/16 PRELIMINARY FD. REV 'A' 0 06/03/16 FINAL COs ISSUED 1 09/22/16 REVISED ADDRESS 2 3 4 5 6 7 8 9 GOFF PROJECT NO.: 01,116000-152 DRAWN BY: I CHECKED BY: SS IMM at&t 1101 GREENWOOD BLVD LAKE MARY, FL 32746 FAX (407) 771-1398 smart 1997 ANNAPOLIS EXCHANGE PKWY. SUITE 200 ANNAPOLIS, MD 21401 PREPARED BY: p JUSAENINEERING 2130 ASHLEY OAKS CIRCLE SUITE 102 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA#3 0705 ♦♦♦jg116t#F,� ♦ Ci :• NO 72513 ' ,STATE 01= e 00 SEPTEMBER 22, 2016 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72S13 Jo2o-MAYPORT FA #10020470 1545 MAIN STREET 4TLANTIC BEACH, FL 32233 SHEET DESCRIPTION SITE PLAN SHEET NUMBER C-1 A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY THE OWNER'S AGENT TO CERTIFY THAT THE EXISTING/PROPOSED COMMUNICATION STRUCTURE AND COMPONENTS ARE STRUCTURALLY ADEQUATE TO SUPPORT ALL EXISTING AND PROPOSED ANTENNAS, COAXIAL CABLES AND OTHER APPURTENANCES. THE OWNER'S AGENT SHALL FURNISH A CERTIFICATION LETTER SEALED BY A REGISTERED PROFESSIONAL ENGINEER STATING THAT THIS STRUCTURAL ANALYSIS WAS PREPARED IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. 2. IF ANY WORK IS PERFORMED AT THIS SITE THAT REQUIRES THE SITE TO BE OFF AIR OR TURNED DOWN, THE SWITCH IS TO BE NOTIFIED 48 HOURS PRIOR TO CONSTRUCTION VIA NCR/CTS. 3. INSTALLATION SHALL BE CONDUCTED BY FIELD CREWS EXPERIENCED IN THE ASSEMBLY AND ERECTION OF RADIO ANTENNAS, TRANSMISSION LINES, AND SUPPORT STRUCTURES. ANTENNA WORK TO BE INSTALLED PER THE REQUIREMENTS OF THE TOWER MANUFACTURER'S SPECIFICATION. 4. ANTENNA AND MOUNT DESIGN MUST COMPLY WITH TIA-EIA-222-G AND ALL LOCAL CODES. 5. CONTRACTOR TO PROVIDE THE PROPER COAX JUMPER SUPPORT ATTACHMENTS TO THE TOWER AND ANTENNA MOUNT. THE CONTRACTOR MUST FIELD VERIFY ALL MEASUREMENTS AND FIELD CONDITIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. i TOWER EL SCALE: N.T.S. HIGHEST APPURTENANCE ELEV. = 195'-0" AGL TOP OF TOWER ELEV. = 193'-O" AGL q OF EXISTING AND PROPOSED AT&T ANTENNASk, ELEV. = 190'-0" AGL (L OF EXISTING ANTENNAS ELEV. = 178'-0" AGL OF EXISTING ANTENNAS%\ ELEV. = 161'-0" AGL FAA APPROVED HEIGHT IS 207' AGL. DO NOT NEST THE BEACON LIGHT, TOP OF ALL AT&T EQUIPMENT MUST BE BELOW THE BEACON LIGHT. IF MAX OPERATING HEIGHT OF CRANE EXCEEDS 207' AGL, FAA CRANE APPROVAL IS REQUIRED. ATION OF EXISTING ANTENNAS ELEV. = 130'-0" AGL EXISTING SELF SUPPORT TOWER q OF EXISTING ANTENNAS ELEV. = 48'-0" AGL EXISTING AT&T WAVEGUIDE BRIDGE EXISTING AT&T EQUIPMENT SHELTER EXISTING TMA IN POSITION #1 AND #4 TO REMAIN (2 PER SECTOR, 6 TOTAL) G3 ELEV. 190'-0" EXISTING RRUS-12 TO REMAIN ON EXISTING BACK-TO-BACK RRU MOUNT �Pl BEHIND ANTENNA IN POSITION #2 R y `GPS A� G2 (1 PER SECTOR, 3 TOTAL) 5�C(O 81 EXISTING RRUS-12 W/A2 MODULE ON G1 EXISTING BACK-TO-BACK RRU MOUNT TO BE REPLACED (1 PER SECTOR, 3 TOTAL) SFC) 82 OR B3 B4 EXISTING ANTENNA CONFIGURATION DETAIL SCALE: N.T.S. i x d Q INSTALL PROPOSED RRUS-32 B2 AND RRUS-12 ON EXISTING BACK—TO—BACK b RRU MOUNT IN POSITION #2 o II (TYPICAL PER SECTOR) N INSTALL PROPOSED FILTER `GPS' S�G�O� Py i BEHIND ANTENNA POSITION #3 (ALPHA AND BETA SECTOR ONLY) SFcT R ? I -e . 720• -,qJ 3 PROPOSED ANTENNA CONFIGURATION DETAIL S-1 SCALE: N.T.S. REV EXISTING ANTENNA IN POSITIONS a #1, #2, #3 & #4 TO BE a TO REMAIN 1 (4 PER SECTOR, 12 TOTAL) 0 o II v Al EXISTING RRUS-11 AND RRUS-32 ON O A3 A4 EXISTING BACK-TO-BACK RRU MOUNT w ul BEHIND ANTENNA IN POSITION #3 TO 6 REMAIN (2 RRUS PER SECTOR, 3 TOTAL) 7 (2) EXISTING RAYCAP DC FIBER G4 DEMARCATION BOX MODEL# 9 DC6-48-60-18-8F TO REMAIN EXISTING TMA IN POSITION #1 AND #4 TO REMAIN (2 PER SECTOR, 6 TOTAL) G3 ELEV. 190'-0" EXISTING RRUS-12 TO REMAIN ON EXISTING BACK-TO-BACK RRU MOUNT �Pl BEHIND ANTENNA IN POSITION #2 R y `GPS A� G2 (1 PER SECTOR, 3 TOTAL) 5�C(O 81 EXISTING RRUS-12 W/A2 MODULE ON G1 EXISTING BACK-TO-BACK RRU MOUNT TO BE REPLACED (1 PER SECTOR, 3 TOTAL) SFC) 82 OR B3 B4 EXISTING ANTENNA CONFIGURATION DETAIL SCALE: N.T.S. i x d Q INSTALL PROPOSED RRUS-32 B2 AND RRUS-12 ON EXISTING BACK—TO—BACK b RRU MOUNT IN POSITION #2 o II (TYPICAL PER SECTOR) N INSTALL PROPOSED FILTER `GPS' S�G�O� Py i BEHIND ANTENNA POSITION #3 (ALPHA AND BETA SECTOR ONLY) SFcT R ? I -e . 720• -,qJ 3 PROPOSED ANTENNA CONFIGURATION DETAIL S-1 SCALE: N.T.S. REV DATE DESCRIPTION A 05/24/16 PRELIMINARY CDs REV -A- 0 06/03/16 FINAL CDs ISSUED 1 09/22/16 REVISED ADDRESS 2 3 4 5 6 7 a 9 GOFF PROJECT NO.: 01 81 6000-1 52 DRAWN BY: CHECKED 8Y: SS MM 1101 GREENWOOD BLVD LAKE MARY, FL 32746 FAX (407) 771-1398 smart 1997 ANNAPOLIS EXCHANGE PKWY. SUITE 200 ANNAPOLIS, MD 21401 PREPARED BY: IS USA 2130 ASHLEY OAKS CIRCLE SUITE 102 WESLEY CHAPEL, FL 33544 (FL C,994-0365 OA#3 O 05 `,,�� V P- 'fid •`` NO 72513 ATE OF a "•.• „� ti5,'.,.. R 1 ••.• G��w� SEPT EMBER 22, 2016 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 JoZo-MAYPORT FA #10020470 1545 MAIN STREET %TLANTIC BEACH, FL 32233 SHEEE DESCRIPTION TOWER ELEVATION AND ANTENNA ORIENTATION SHEET NUMBER S-1 ERICSSON RRUS 32 EXISTING MOUNTING PIPE -DIMENSIONS (H x W x D): 27.2" x 12.1" x 7.0" (INCLUDES SUNSHIELD) -WEIGHT: 60 LBS ANTENNA -WCS A+B BLOCKS: TX = 2350-2360 MHz RX = 2305-2315 MHz -CPRI 2 PORTS x 10 GBPSUNIVERSAL RRU MOUNT 20! mm _ ___ 144.5 mm f (ROSENBERG R #D215RRU) (8 2In) (5.7 in) 12.1 am>� Tm - :1 L B 0 0 0 206 mm (l1,1 in) oI O N RRUW/ RRU A2 MODULE ti - � � 1' 3 N ERI,Slo" ru i ti aur i u:r � E O O +° 144.5 mm n o NOTE: O O (5.7 in) rn RRUS CAN ONLY BE NOTE: a PAINTED ON SOLAR SHIELD. DETAIL IS DIAGRAMMATIC, CONTRACTOR Fa ANl 1 FhfT 6 U TO INSTALL RRU'S AND/OR RRU'S W/A2 MODULES ON RRU MOUNT BEST SUITED FOR ANTENNA CONFIGURATION. RRUS-32 DETAIL E15V87P73 BACK VIEW O �1 TS -2 SCALE: N.T.S. S-2 SCALE: N.T.S. 0 n KEYNOTE LEGEND: 1. SECTOR GROUN BAR (TYP). ANTENNA 2. COLLECTOR GRQILIND BAR. U 3 3. NEW ANTENNA 'i 4. SINGLE PAIR FlOER & DC POWER. m 5. JUMPER CABLE, 1/2" " 6. PIPE MOUNT. EXISTING MOUNTING PIPE � 7. DC POWER & FIBER TO RAYCAP UNIT. REMOTE8. RADIO 9. D 6RAYCAPS RGE SUPPRESISOR (F APPLICABLE). UNIVERSAL RRU MOUNT 6 6 (ROSENBERGER #D215RRU) L 4 CL E i s 3 12 AWG SOLID BARE TINNED d COPPER (TYP) E N I 12 AWG SOLID BARE TINNED COPPER (TIP) RRU W RRU ui G) A2 MODULE C3 NOTE: (D 12 IS DIAGRAMMATIC. CONTRACTOR 2 �2 AWG SOLID BARE TO INSTALL RRU'S AND/OR RRU'S W/A2 MODULES ON RRU MOUNT BEST SUITED TINNED COPPER (TYP) FOR ANTENNA CONFIGURATION. I 1. UTILIZE DOSIT AT&T GROUND BARS AND GROUNDING. L 2. ADD GROUND IF THERE ARE INSUFFlCIENT LUG POSITIONS. c 3. REFERENCE AT*T BONDING & GROUNDING PRACTICE TP76416. rn W 3 ANTENN# GROUNDING SCHEMATIC DOUBLE RRU MOUNTING DETAIL rn S-2 SCALE: N.T.S. S-2 SCALE: N.T.S. REV DATE DESCRIPTION A 05/24/16 PRELIMINARY CDs REV 'A' 0 06/03/16 FINAL CDs ISSUED 1 09/22/16 REVISED ADDRESS 2 3 4 5 6 7 8 9 GOFF PROJECT NO.: 01 81 6000-1 52 DRAWN BY: I CHECKED:BY: 1. SS MM 1101 GREENWOOD BLVD LAKE MARY, FL 32746 FAX (407) 771-1398 �)martlin 1997 ANNAPOLIS EXCHANGE PKWY SUITE 200 ANNAPOLIS, MD 21401 PREPARED BY: GIENGINEERING 2130 ASHLEY OAKS CIRCLE SUITE 102 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA #31705 ,,�e�t,rrrrrrrr,�. ��� paG• P. 444```r. k • No 72513 STATE OF •` 0 Na SEPTEMBER 22, 2016 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 i JOZO-MAYPORT FA #I0OZO470 1545 MAIN STREET ATLANTIC BEACH, FL 32233 SHEET DESCRIPTION MISCELLANEOUS DETAILS SHEET NUMBER S-2 N ANTENNA & COAX SCHEDULE N- SCALE: N.T.S. REV DC / FIBER DEMARCATION BOX RAYCAP DC FIBER DEMARCATION 3OX CABLES NOTES MOUNTING HEIGHT MODEL LENGTH PER QTY MODEL SIZE QTY LINE RRU 190'-0" DC6-48-60-18- F 2 ROSENBERGER (18) PAIR FIBER TRUNK 3/8" 2 220'-0" TMA (6)-#8 AWG TIN NED COPPER CONDUCTORS 3/4" 4 220'-0" ANTENNA ANTENNA & COAX SCHEDULE N- SCALE: N.T.S. REV ANTENNA AND COAX SCHEDULE A 05/24/16 PRELIMINARY CD- REV A- ANTENNAS 06/03/16 FINAL CDs ISSUED CABLES RRU A2 DIPLEXER/FILTER TMA RAD ANTENNA APPROXI ATE DOWNTILT 7 LENGTH/ COLOR 9 GOFF PROJECT NO.: 01 81 6000-1 52 TWR GRND SS MM MOD MAKE MODEL ELEC MECH (QTY) SECTOR AZ CENTER (QTY) ANTENNA PEGS MODEL SIZE (QTY) LINE CODE MODEL (QTY) MODEL (QTY) (QTY) MODEL (QTY) ALPHA (Al) 0° 190'-0" ANDREW DBXNH-6565B-R2M 1 H=73.4" x W=11.9" x D=7.1" LDF7-50A 1-5/8" 2 220'-0" 1 RED CM1007-DBPXBC-002 2 E15S09P78 1 ALPHA (A2) 0 190'-0" ANDREW SBNHH-1D65B 1 H=72" x W=11.9' x D=7.1" 7/4° 0° ROSENBERGER FIBER JUMPER (DC6 TO RRU) 3/8" 2 15'-0" 2RED RRUS-12 1 ROSENBERGER SINGLE PAIR DC CABLE (DC6TO RRU) 7/16" 2 15'-0" 2 RED RRUS-32 B2 1 1/2" COAX JUMPER (RRU TO ANTENNA) 1/2" 6 6'-0" 2RED ALPHA (A3} 0° 190'-0" ANDREW SBNHH-1D65B 1 H=72" x W=11. " x D=7.1" 7°/4° 0° - - - ROSENBERGER FIBER JUMPER (DC6TO RRU) 3/8" 2 15'-0" 3 RED RRUS-32 1 E15V8P73 1 ROSENBERGER SINGLE PAIR DC CABLE (DC6TO RRU) 7/16" 2 15'-0" 3 RED RRUS-11 1 1/2" COAX JUMPER (RRU TO ANTENNA) 1/2" 2 6-0" 3 RED 1/2" COAX JUMPER (RRU TO FILTER) 1/2" 4 6'-0" 3 RED 1/2" COAX JUMPER (FILTER TO ANTENNA) 1/2" 4 6'-0" 3RED ALPHA (A4) 0° 190'-O" ANDREW DBXNH-65658-R2M 1 H=73.4" x W=11. " x D=7.1" LDF7-50A 1-5/8" 2 220'-0" 4 RED CM1007-DBPXBC-0021 1 2 1 E15SO9P78 1 BETA (Bl) 120° 190'-0" ANDREW DBXNH-6565B-R2M 1 H=73.4" x W=11.9" x D=7.1" LDF7-50A 1-5/8" 2 220'-0" 1 BLUE CM1007-DBPXBC-002 2 E1SSO91`78 1 BETA (132) 120° 190'-0" ANDREW SBNHH-1D65B 1 H=72" x W=11. " x D=7.1" 6°/3° 0° ROSENBERGER FIBER JUMPER (DC6 TO RRU) 3/8" 2 15'-0" 2RED RRUS-12 1 ROSENBERGER SINGLE PAIR DC CABLE (DC6TO RRU) 7/16" 2 15'-0" 2 RED RRUS-32 B2 1 1/2" COAX JUMPER (RRU TO ANTENNA) 1/2" 6 6'-0" 2 RED BETA (83) 120° 190'-0" ANDREW SBNHH-1D65B 1 H=72' x W=11. " x D=7.1" 6°/3° 0° - - - ROSENBERGER FIBERJUMPER(DOSTORRU) 3/8" 2 15'-0" 3BLUE RRUS-32 1 EISVBP73 1 ROSENBERGER SINGLE PAIR DC CABLE (DC6TO RRU) 7/16" 2 15'-0" 3BLUE RRUS-11 1 - 1/2" COAX JUMPER (RRU TO ANTENNA) 1/2" 2 6'-0" 3 BLUE 1/2" COAX JUMPER (RRU TO FILTER) 1/2" 4 6'-0" 3 BLUE 1/2" COAX JUMPER (FILTER TO ANTENNA) 1/2" 4 6'-0" 3BLUE BETA (64) 120° 190'-0" ANDREW DBXNH-6565B-R2M 1 H=73.4" x W=11. "x D=7.1" LDF7-50A 1-5/8" 2 220'-0" 46LUE CM1007-DBPXBC 002 2 E15509P78 1 GAMMA (Gl) 240° 190'-0" ANDREW DBXNH-6565B-R2M 1 H=73.4" x W=11.9" x D=7.1" LDF7-50A 1-5/8" 2 220'-0" 1 GREEN CM1007-DBPXBC-002 2 E15SO9P78 1 GAMMA (G2) 240° 190'-0" ANDREW SBNHH-1D65B 1 H=72" x W=11. " x D=7.1" 6°/3° 0° - - - ROSENBERGER FIBERJUMPER (DC6TO RRU) 3/8" 2 15'-0" 2RED RRUS-12 1 - - ROSENBERGER SINGLE PAIR DC CABLE (DC6TO RRU) 7/16" 2 15'-0" 2 RED RRUS-32 B2 1 1/2" COAX JUMPER (RRU TO ANTENNA) 7./2" 6 V.O.. 2RED GAMMA (G3) 240° 190'-0" ANDREW SBNHH-1D65B 1 H=72" x W=11.9" x 0=7.1" 6°/3° 0° ROSEN BERGER FIBER JUMPER (DC6 TO RRU) 3/8" 2 15'-0" 3GREEN RRUS-32 1 ROSENBERGER SINGLE PAIR DC CABLE (DC6TO RRU) 7/16" 2 15'-0" 3 GREEN RRUS-11 1 1/2" COAX JUMPER (RRU TO ANTENNA) 1/2" 6 6'-0" 3GREEN GAMMA (G4) 240° 190'-0" ANDREW I DBXNH-65658-R2M 1 H=73.4" x W=119" x D=7.1" LDF7-50A 1-5/8" 2 220'-0" 4 GREEN CM1007-DBPXBC-002 2 E15509P78 1 *ANTENNA AND COAX INFORMATION PROVIDED FROM THE LTE WCS FILTER RFDS SHEET V2.00 D TED 04/25/16. TOTAL 1-5/8" COAX (ACTIVE) _ 12 2640'-0" TOTAL 12 0 TOTAL 1 2 1 12 1 TOTAL 6 * CONTRACTOR TO VERIFY RF IN FO WITH CLIENT PRIOR TO CONSTRUCTION. TOTAL FIBER JUMPER 12 1801-0" * COAX LENGTHS ARE APPROXIMATE AND MUST BE VERIFIED PRIOR TO CONSTRUCTION. TOTAL DC JUMPER 12 180'-0" *ALL COAX SHALL BE COLOR CODED ATTOP AN BOTTOM JUMPER AND ATTOP OF TOWER TOTAL 1/2" JUMPERS 44 264 -4 - BOTTOM OF TOWER, AND INSIDE SHELTER ON MAIN COAX. TOTAL 5/16" RET CABLES 3 660'-0" ' EACH MAIN COAX SHALL HAVE CORROSION PROOF "ID TAGS" INSTALLED INSIDE THE SHELTER ANTENNA & COAX SCHEDULE N- SCALE: N.T.S. REV DATE DESCRIPTION A 05/24/16 PRELIMINARY CD- REV A- 0 06/03/16 FINAL CDs ISSUED 1 09/22/16 REVISED ADDRESS 2 3 4 5 6 7 8 9 GOFF PROJECT NO.: 01 81 6000-1 52 DRAWN BY: I CHECKED BY: SS MM at&t 1101 GREENWOOD BLVD LAKE MARY, FL 32746 FAX (407) 771-1398 smart 1997 ANNAPOUS EXCHANGE PKWY. SUITE 200 ANNAPOLIS, MD 21401 PREPARED BY: 9 (ENGINEERING 2130 ASHLEY OAKS CIRCLE SUITE 102 WESLEY CHAPEL, FL 33544 (813) 994-0365 FL COA X131705 1 No 72513 �: STA -TE OF • SEPTEMBER 22, 2016 MARC P. MAIER, PE FL PROFESSIONAL ENGINEER LIC. # 72513 J02o-MAYPORT FA #10020470 1545 MAIN STREET TLANTIC BEACH, FL 32233 SHEET DESCRIPTION ANTENNA SCHEDULE SHEET NUMBER AN -1