2400 SEMINOLE RD - PERMIT ACRS18-02434 i I I N otes HVAC"P* HVAC Notel W HVAC Notes 1.0 Design Criteria 5.5 The FRC Vera 6 M1507.4 requires that all bath exhaust fans have a minimum airflow of 50 cfm. The 11.0 Thermostats • the table below. 11.1 Honeywell Vision Pro 8000 Temporary Thermostats with the ventilation feature turned off. X Ver. 6 Florida Building Code specified bath exhaust fans are listed in r Ver. 6 Florida Mechanical Code 12.0 Buildin S eclficat>ons , Ver. 6 Florida Energy Conservation Code BATH EXHAUST `FANS Z 12.1 Kitchen exhaust make up air will be provided as required, via a 10 inch make up air duct that penetrates the a }� (� ACCA Manual J 8th edition All terminating in a J vent. The duct will have a Normally Closed Power Open damper that will receive it's All Exhaust Fans Panasonic FV -05-11 VKSL 1 or equivalent signal from a pressure switch in Aglow Wthe kitchen exhaust duct or by a relay connected to the kitchen exhaust ACCA Manual S controls. This same signal will he used to activate the hvac zone in which the kitchen is located. ACCA Manual D 2009 -2014 Rev. Z ACCA Manual T 6.0 Return (frills 12.2 Gas Dryer make. up air FRC Ver.6 G2439.5 requires an opening of not less than 100 sq. inches.. This shall � 6.1 All return rills are to be Aluminum louvered style. Stamped grills are not permitted. be provided via 12" jumper style duct connected to two 14"x8" fixed louvered grills. 2.0 Installation Notes g y LL connection shall be verified with manufacturer specifications. 2.1 Equipment r 6.2 All return grills are to be H&C RCB Grilles or Air Guide RA -CB. Substitutions must be approved in advance. 13.0 Manual S ! !i - 6 R403.3.6 requires: � 2.2 If any equipment is to be located in the attic then FECC Ver. q 2.2.1 The service panel must be located within 6 feet of the attic access 7.0 HVAC Specifications r 7.1 All rooms with an 8x4 grill will require an OBD grill similar to H&C A611 OBD or Air Guide CB -OB -l. 2.2.2 A device installed to alert homeowner or shutdown the unit when the condensate drain is malfunctioning. � 2.2.3 The attic access opening is large enough to replace the unit. Substitutions must be approved in advance. 2.2.4 A notice is posted on the electrical service panel indicating to the home owner that the air handler is located 7.2 All duct board dimensions are internal dimensions. Use 1.5 inch duct board unless specified otherwise. in the .attic. 2.3 If any equipment is to be located in the attic then FRC -Ver 6 M1345.1.3 requires: 7.3 FRC Ver. 6 M1305.1.1 must provide a 3" minimum clear space around all air handlers. 2.3.1 An unobstructed passageway large enough to allow removal of the largest object - the passageway shall be 8.0 HVAC Zonin level with continuous flooring and be at least 24 wide and not more than 72 " long. Also a work space in shall be at least 30" wide and 30" long. A light fixture with receptacle outlet controlled 8.1 All supply zoning dampers shall be Honeywell ARD**TZ style or equivalent. front of the appliance by a switch at the passage entrance is also required. 8.2 All zoning system will have a bypass duct and damper with the duct. size shown on the drawing. 3.0 Air Distribution System and sealing to adhere to the sealing and mechanical attachment requirements 8.3 The bypass damper will be a Honeywell TrueZONE Bypass CPRD or equivalent. 3.1 All duct system constructiong g specified in the SMACNA standards. 9.0 HVAC Filters 3.2 All duct sizes lists are clear Inside dimensions. 9.1 All air Handlers will be equipped with a low static filter assembly. One inch pleated filters are NOT permitted. 3.3 All flexible duct runs are to be cut to length with a maximum of 5% greater than the span length is permitted. 10.0 HVA( Legend 3.4 All connections to be sealed with UL 181 approved mastic. Tape is not permitted as the primary seal. 3.5 No crimping or crushing is permitted at any point. 3.6 The mixing box entrance connection is to be made at the end of the box. All secondary ducts will be connected on the sides, top or bottom of the box. No secondary ducts may be connected to the ends of the mixing box. 3.7 All rigid trunks are to be fabricated from 1.5 inch fiberglass duct board unless otherwise specified. 3.8 All flexible ducts are t o be fabricated from flex ducts with R6 insulation. e 4.0 Supply Grills 4.1 All supply grills are to be louvered style. Stamped grills are not permitted 4.2 All single throw supply grills are to be H&C A611 or Air Guide CB -1. Substitutions must be approved in advance. 4.3 All double throw supply grills are to be H&C A612 or Air Guide CB -2. Substitutions must be approved in advance. 4.4 The grill sizes listed in the Manual D or in the drawing may not be changed without prior approval. 4.5 Grill. locations may be altered to accommodate nearby trusses. 5.0 Exhaust and Ventilation r 5.1 Run time ventilation is provided for each system: A six inch flexible duct will connect to the dehumidifier intake to a 14 inch non metallic pipe that penetrates the roof and terminates in a west facing J vent. Each intake duct will have a Manual Balancing damper and a Normally Closed Power Open damper installed in the duct at the dehumidifier. This will permit outside air to enter only when the system is running. There will also be labeled "Ventilation Off" shut off switch located at the dehumidifier to permit manual override. IVAC Equipment Specifications - BOSCH / FHP Flex Duct with R-6 insulation Rigid Duct - Fiber Board - all dims are ID 1 2 H&C A611 Single Throw Supply Grill or Equivalent 4 2X6 H&C A612 Double Throw Supply Grill or Equivalent Condenser SM024-ICS 12x12 SM036-ICS H&C RH45 or RCB Return Grill or Equivalent SM036-1CS AHU Supply Air handler SM024-IAV/AH SM048-IAV/AH SM036-IAV/AH AHU Return SM036-IAV/AH rEq Honeywell TrueZONE Bypass Damper or equivalent 7499701 8.10 Duct Size Symbol - 8" 7499707 7499707 Supply Flex Duct Floor Penetration SEER (2) Return Flex Duct Floor Penetration 22.5 22.5 Manual Balancing Damper 22.9 Nominal Tons Thermostat 4.0 CO) Supply Zone Damper NOPC 2.0 QA Two way grill 2.2 @ Wall grill 3.1 3.1 Secondary Bath Fan > 50 cfm Detailed Cooling capcity 26,032 Humidity Sensing Bath Exhaust Fan 37,198 37,198 Round Galvanized steel duct, R-6 Ins., all dims ID p- Detailed Sensible capacity Rect Galvanized steel duct, R-6 Ins., all dims ID 38,509 .. Fresh Air NCPO & Manual Dampers IVAC Equipment Specifications - BOSCH / FHP System Number 1 2 3 4 5 Total Condenser SM024-ICS SM048-ICS SM036-ICS SM036-1CS SM036-1CS Air handler SM024-IAV/AH SM048-IAV/AH SM036-IAV/AH SM036-IAV/AH SM036-IAV/AH AHRI Number 7499701 7499711 7499707 7499707 7499707 SEER 24.9 21.7 22.5 22.5 22.5 22.9 Nominal Tons 2.0 4.0 3.0 2.0 2.0 13.0 Real Tons 2.2 4.2 3.1 3.1 3.1 15.6 Detailed Cooling capcity 26,032 49,921 37,198 37,198 37,198 150,349 Detailed Sensible capacity 21,248 38,509 28,576 28,576 28,576 116,909 Detailed Latent capacity 4,784 11,412 8,622 8,622 8,622 33,440 Adjusted sensible capacity 22,330 42,343 31,707 32,572 32,870 128,951 Adjusted Latent capacity 3,703 7,578 34,170 4,626 4,329 50,077 Airflow 492 1,485 1,168 985 960 4,130 Heat Strips KW 5 8 8 8 8 LLLL Zones 2 3 3 2 2 10 Water Flow - GPM 6 12 9, 9 9 36 W J Q U I U) (D Z i, LL i • i I . r••� i t CZ j V1 U) W (D .J Z_ ZLLJ Z1 W r V) NJ LLJ ,..., W U M . �/ 1 W that Exhaust Hoods stems capable of exhausting in. excel --I 5.2 The Florida Mechanical Code - Ver. 6 505.2 requires Y p ��• ® < of 400 >cfm shall be provided with make up air at a rate approximately equal to the exhaust air rate." Therefore, if the kitchen exhaust exceeds 400 cfm provisions for make up air are required. Exception: more than 400 cfm ■M but no more than 800 cubic feet per minute if there are no gravity vent appliances within the conditioned living O space of the structure. If make up air is required, see section 12.1 T\4 0 Z Q 5.3 All second floor bath exhaust will coonect to a 10 inch non metallic pipe that penetrates the roof It will terminate C1 in a west facing J vent. i � REVIEWED FOR CODE COMPLIANCE L!AVCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDI'FItONAL REQUIREMENTS AND CONDITIONS F REVIEWED By.---Z21DATE: i OFFICE COPY SYSTEM 2 Family Room, Living room & Dining room Supply Trunk Sizes Trunk 2T 1 Size 12"W x 12"H ID - metal Trunk 2T2 Size 13 "W x 13 "H ID - metal Trunk 2T3 Size 11 "W x I IH ID - metal. Trunk 2T4 Size 6"W x 12H ID - metal Trunk 2T5 Size 6"W x 12H ID - metal Return Trunk Sizes Trunk 2RT1 Size 16"W x 16H ID - metal Trunk 2RT2 Size 11"W x 1IH ID -metal Trunk 2RT3 Size 6"W x 12H ID - metal NOTES all insulated metal ducts -unless otherwise noted Ultra Aire 98 H dehumidifier - Ducted metal manual balancing dampers where shown SYSTEM I Basement apartment & mechanical rooms Supply Trunk Sizes Trunk IT 1 Size 9"W x 12"H ID - metal Trunk 1T2 Size 6"W x 6"H ID - metal Trunk 1T3 Size 6"W x 9"H ID - metal Trunk 1 T4 Size 9"W x 6"H ID - metal Return Trunk Sizes No Trunk 1811x18" grill NOTES Installed vertically Return grill located in the return plenum wall pass thrun returns all insulated metal ducts apartment supplies in the trunks mechanical supplies in the walls freestanding Ultra Aire 74 H dehumidifier manual balancing dampers where shown ULTRA- AIRE 98 DEHUMIDIFER Supply Duct 101" Return Duct " 101 Outside Air Duct 61' NOTES All ducts insulated metal Manual balancing dampers on the outside air duct NCPO damper on the outside air duct Check valve on the supply duct The Unit is to be suspended on an isolation frame SANTE FE COMPACT 2 DEHUMIDIFIER Supply Duct none Return. Duct none Outside Air Duct none NOTES Free Standing dehumidifier Condensate to be hard piped The Unit is rest on isolation pads U) (.7 Z L W U) W W J Q U U) 0 Z 0 S1eima'id'fti,r0(ff,_esid ed'oftce Basement Mechanical Plan Scale 1/4"=1' LLI J� ZW oZ U =OU Q C a cn Revised: 1 Drawn by: MOD Drawing No. CHASE 4"Dxl2"W (TYP) CHASE- 4"Dxl2"W (TYP) �ps U) (D z ry 0 W W r F- J Q U U 0 Z 0 d 4"Dx12"W (TYP) Sielman Residence MainFloor Mechanical Plan Scale 1/4"=1' �:,, 11 the attic 711 ler `" _......:' a_W.,�..._ . j o e� HER BATH (Aio U) 0 z_ Q 0 W U) W W J Q U U F- 0 z 0 0 Sleima,id"'i", Residence Secon 1 Floor Mechanical Plan 7 E ! 711 } w 13, Two ducts drop down from the attic Scale 1/411�11 m LLJ ;z Z� U0 MJ LU am Drawn by: MOD � M3 OFFICE COPY r .P OA 0 BEDROx OM 1 — — — — 5t-41 10'-7" 5'-4" MASTER System 2 Fresh Air duct up to the attic w 1 Floor Mechanical Plan 7 E ! 711 } w 13, Two ducts drop down from the attic Scale 1/411�11 m LLJ ;z Z� U0 MJ LU am Drawn by: MOD � M3 OFFICE COPY SYSTEM 5 Bedrooms 1 and 2e Supply Trunk Sizes Trunk 5 T 1 Size 14" Trunk 5T2 Size 12" Return Trunk Sizes Trunk 4RT 1 Size 18" NOTES All ducts insulated non metal -unless otherwise noted Manual balancing dampers where shown The AHU is to be suspended on an isolation frame SYSTEM 4 Owners Suite Supply Trunk Sizes Trunk 4T l Size 16" Trunk 4T2 Size 121" NOTES All ducts insulated non metal -unless otherwise noted Manual balancing dampers where shown The A14U is to be suspended on an isolation frame SYSTEM 3 Foyer, Kitchen, Office Supply Trunk Sizes Trunk 3 T 1 Size 12" Trunk 3T2 Size 10" Trunk 3T3 Size 10" Trunk 3T4 Size 10"W x 8"H ID Trunk 3T5 Size 9" Trunk 3T6 Size 9"W x 6"H ID Trunk 3T7 Size 10" Trunk 3T8 Size 6" Return Trunk Sizes Trunk 3 RT 1 Size 1211 Trunk 3RT2 Size 1211 Trunk 3RT3 Size 12" Trunk 3RT4 Size 16"W x 12H ID NOTES All ducts insulated non metal -unless otherwise noted Manual balancing dampers where shown The AHU is to be suspended on an isolation frame ULTRA- AIRE 98 H DEHUMIDIFERS Supply Duct 10" Return Duct 1'01' Outside Air Duct 6" NOTES All ducts insulated metal Manual balancing dampers on the outside air duct NCPO damper on the outside air duct Check valve on the supply duct The Unit is to be suspended on an isolation frame .. . air dehumidifier iBntake duets connected`$µ� .._----- 511 41 to it. This 14 inch duct penetrates the y. ,. roof and terminates ina J vent that faces s '" west: Tl ck"s fi F' Sleiman Residence Attic Mechanical Plan Scale 1 /4"=1' 0 10 1+1 UA 98H 10 A 10 '2 3RT2 ,.Of 3RT3 Sleiman Residence Attic Mechanical Plan Scale 1 /4"=1' 0 10 1+1 UA 98H 10 A 10 1 cit OFFICE COPY '2 3RT2 3RT3 12 1 cit OFFICE COPY