Loading...
1665 SELVA MARINA DR - PERMIT POOL18-0004 DWGSGENERAL NOTES: CODE USED: 2017 FLORIDA BUILDING CODE CONTRACTOR SHALL VISIT SITE TO OBSERVE CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS AND CONDITIONS PROVIDED ON DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCIES WITH THE ENGINEER PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF THE PUBLIC AND ALL CONSTRUCTION PERSONNEL AND MUST COMPLY WITH ALL APPLICABLE OSHA SAFETY REQUIREMENTS THROUGHOUT THE DURATION OF THE WORK. THE CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION, SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO DEMOLITION AND CONSTRUCTION EQUIPMENT, ETC. THE ENGINEER OF RECORD SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS). WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDA. MASONRY CONSTRUCTION: CONCRETE MASONRY UNITS (CMU): SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C 90 AND SHALL HAVE A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1900 PSI WHEN USING TYPE M OR S MORTAR (ASTM C 270) IN ACCORDANCE WITH ACI 530, THE 1900 PSI BLOCK IN COMBINATION WITH TYPE M OR S MORTAR PROVIDES A DESIGN COMPRESSIVE STRENTH (f'm) OF 1500 PSI. NOTE: CONTRACTOR TO FIELD VERIFY CLEARANCES, DIMENSIONS, AND OTHER APPLICABLE FIELD CONDITIONS PRIOR TO COMMENCING WORK. SHOULD DISCREPANCIES BE DISCOVERED, ALERT EOR IMMEDIATELY. DEFINITIONS: GROUT POUR HEIGHT - THE TOTAL HEIGHT OF MASONRY TO BE GROUTED PRIOR TO ERECTION OF ADDITIONAL MASONRY. GROUT POUR - CONSISTS OF ONE OR MORE GROUT LIFTS. GROUT LIFT - THE LAYER OF GROUT PLACED IN A SINGLE CONTINUOUS OPERATION AND IS LIMITED TO 5 FEET (1524 MM). RODDING - THE ACT OF COMPACTING FRESHLY POURED CONCRETE OR GROUT IN iTS FORM BY FREEING THE MASS OF AIR POCKETS WITH REPEATED STABS OF A ROD. PUDDLING - THE PROCESS OF INDUCING COMPACTION OF GROUT BY USE OF A TAMPING ROD. PUDDLE - THE ACT OF WORKING CONCRETE TO ELIMINATE HONEYCOMB, AND TO PRODUCE A DENSER MASS. PUDDLE STICK - A STICK OR ROD USED TO CONSOLIDATE GROUT BY HAND, MASONRY CONSTRUCTION AND INSPECTION GUIDELINES: 1. LAY UP MASONRY IN RUNNING BOND FOR SIZES AND REINFORCING PER PLANS AND ELEVATIONS. 2. FACE SHELLS OF BED JOINT SHALL BE MORTARED. 3. WEBS SHALL BE MORTARED AT CELLS TO BE GROUTED. 4. VERTICAL CELLS ARE TO BE ALIGNED WHERE THEY ARE TO BE GROUT FILLED UNLESS BOND IS SHIFTED DUE TO SITE CONDITIONS. 5. INSTALL HORIZONTAL JOINT REINFORCING AT 16 INCHES (407 MM) ON CENTER STARTING FIRST BLOCK ABOVE FOUNDATION. 6. MAINTAIN MINIMUM OF 1/2 INCH (12.7 MM) COVER ON JOINT REINFORCING TO EXTERIOR AND REINFORCING SHALL BE EMBEDDED IN MORTAR. 7. GROUT SPACES BOTH VERTICAL AND HORIZONTAL ARE TO BE SUBSTANTIALLY FREE OF DROPPINGS, DEBRIS, LOOSE AGGREGATE AND ANY MATERIAL DELETERIOUS TO MASONRY GROUT. 8. INSTALL REINFORCING IN GROUT CELLS PRIOR TO GROUTING. 9. GROUT SPACES ARE TO BE INSPECTED PRIOR TO PLACING GROUT. 10. FILL CELLS AS NOTED ON THE PLANS, ELEVATIONS AND DETAILS. 11. PLACE GROUT IN LIFT TO 60 INCHES IN HEIGHT (CLEAN OUT HOLES ARE NOT REQUIRED). 12. A REINFORCING BAR MAY BE USED TO ROD GROUT IN CELL, TO ENSURE THERE ARE NO VOIDS IN GROUT. 13. PLACE REINFORCING APPROXIMATELY 1 INCH (25 MM) TO THE SIDE OF DOWEL IN CELL (ACI 530-1.12.3.3) 14. GROUT SHOULD SET IN APPROXIMATELY 90 MINUTES DEPENDING ON GROUT SLUMP AND WEATHER CONDITIONS. 15. DO NOT BEND OR MOVE REINFORCEMENT AFTER GROUT HAS SET, 16. FILL ALL CELLS SOLID BELOW FINISH FLOOR ELEVATION. 17. PROVIDE LEVEL "B" QUALITY ASSURANCE, AS PER ACI 530-05 TABLE 1.15.2. TOLERANCES FOR CENTER REINFORCING: CENTERLINE LOCATION SHOULD BE WITHIN 1/2 INCH (13MM) OF CENTER OF MASONRY. HORIZONTAL LOCATION SHALL BE WITHIN 2 INCHES (51 MM) OF THE CENTER OF THE CELL. REINFORCING SHALL MAINTAIN POSITION WITHOUT BEING TIED. DO NOT MOVE REINFORCING AFTER INITIAL SET OF GROUT. REINFORCING AT EACH FACE: MAINTAIN AT LEAST 1/4 INCH (6 MM) CLEAR OF MASONRY FOR FINE GROUT AND 1/2 INCH (13 MM) FOR COARSE GROUT. REINFORCING SHALL BE PLACED 1 INCH CLEAR TO THE SIDE OF THE DOWELS. GROUT: THE GROUT SHALL BE IN ACCORDANCE WITH ASTM C 476 AND SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE OF 3/8" PLACED AT AN 8" TO 11" SLUMP AND HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS WHEN TESTED IN ACCORDANCE WITH ASTM C 1019, STEEL REINFORCEMENT: REINFORCING STEEL: SHALL BE ASTM A615, GRADE 60 STEEL REINFORCEMENT SHALL BE IN ACCORDANCE WITH FBC, ACI 318 AND AS NOTED IN THESE PLANS. CONCRETE COVER SHALL BE IN ACCORDANCE WITH FBC AND AS FOLLOWS: 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 2" FOR CONCRETE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND 1-1/2" FOR CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND VERTICAL AND HORIZONTAL REINFORCEMENT WILL BE LAPPED FOR 36 BAR DIAMETERS OR 24", WHICHEVER IS GREATER. ALL REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAMS AND PLACING DETAILS OF ACI STANDARDS. ALL REINFORCING STEEL SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESORIES DURING PLACING OF CONCRETE. SPLICES IN REINFORCING, WHERE PERMITTED, SHALL BE AS FOLLOWS: MASONRY: 48 BAR DIA. CORNER REINFORCEMENT SHALL BE LAPPED 30". SOILS: MINIMUM ALLOWABLE SOIL BEARING CAPACITY = 2500 PSF SUBSURFACE SOIL CONDITIONS WERE NOT AVAILABLE AT THE TIME OF THIS DESIGN. THE OWNER SHALL PROVIDE TO THE CONTRACTOR A REPORT OF THE SUBSURFACE CONDITIONS. SOIL PREPARATIONS NOTED IN SAID REPORT SHALL BE FOLLOWED UNLESS MORE STRINGENT DESIGN IS SPECIFIED WITHIN THESE PLANS. THE FILL BELOW THE FOUNDATION SHOULD BE FREE OF DEBRIS, ORGANIC MATERIAL, COHESIVE SOILS OR ANY OTHER DELETRIOUS MATERIAL. SOIL MUST BE COMPACTED TO 95% MODIFIED PROCTOR MAXIMUM DRY DENSITY FOR A DEPTH OF 2'-0" BELOW THE BOTTOM OF THE FOOTING, FINISHED LOW GRADE 0 I n. 2._4„ It P cl "a 0 m Lj 'U' Lu a. Ul a�Lu 8" BLOCK WALL WITH #5 AT 4$" O.C. CENTERED. GROUT ALL CELLS SOLID. PROVIDE LADDER TYPE JOINT REINFORCING AT EVERY JOINT. UPPER GRADE PAVERS Lu cc REINFORCE FOOTING WITH (3)#5 LONG WAY t SECTION at MASONRY RETAINING WALL St SCALE: N.T.S. m04 r^ m� zN 0 — o0 cu z V) m o 0 Z 0 ,h'°. N J5nL-M Opo 1: 3 tr% r M t7 Q Zo �of mom o I� N L z a ~ of a 0 uj �- o s o U) �auiA O�W�o a_ LL RETAINING WALL WITH NOTES U w a DRsi AWPNG SHEET: