1067 Beach Ave - DEP - DrawingsHIONIDE5 1067 OCEANFRONT COTTAGE RENOVATION 1067 BEACH AVENUE, ATLANTIC BEACH, FLORIDA 32233 CODE REVIEW: THE PROJECT SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE FOUR VOLUMES OF THE FLORIDA BUILDING CODE, 2014 EDITION 1) VOLUME I — BUILDING, WHICH INCLUDES ENERGY, ACCESSIBILITY AND STATE AGENCY REGULATIONS. 2) VOLUME 2 — PLUMBING 3) VOLUME 3 — MECHANICAL AND FUEL GAS 4) VOLUME 4 — THE NATIONAL ELECTRICAL CODE (STANDARD NFPA 70-2008) 5) FLORIDA FIRE PREVENTION CODE 2012 TH15 HOUSE 15 DESIGNED FOR THE 120 MPH WIND ZONE BUILDING DESCRIPTION: THE PROPOSED PROJECT 15 A NEW TWO STORY COTTAGE. IT WILL HAVE A ONE CAR GARAGE ON THE FIR5T FLOOR AND WILL BE CON5TRUCTED WITH WOOD STUD WALLS WITH R-1 3 BATT INSULATION ON A TURN DOWN CONCRETE SLAB ON GRADE WITH CONTINUOUS VAPOR BARRIER AND A STANDING SEAM METAL ROOF ON PRE—FABRICATED ROOF TRU55E5. AREA SUMMARY EXISTING HOME = 1 ,3 14 G.5.F. / FLOOR = 2,628 G.S.F. NEW COTTAGE = 448 G.5.F. / FLOOR = 696 G.5.F. (FIRST FLOOR OF COTTAGE 15 448 G.5•F- OF UNCONDITIONED SPACE) I CHAPTER 3 OCCUPANCY CLA551171CATION FBC 302.1 THE EXISTING AND PROPOSED STRUCTURES ARE CLA55I1:::IED AS RESIDENTIAL R-3. FBG 3 10.5 RESIDENTIAL GROUP R-3 INCLUDES RESIDENTIAL OCCUPANCIES WHERE THE OCCUPANTS ARE PRIMARILY PERMANENT IN NATURE. I CHAPTER G TYPES OF CONSTRUCTION THE PROJECT'S CONSTRUCTION 15 CLASSIFIED AS TYPE IIB CONSTRUCTION ARE TH05E TYPES OF CONSTRUCTION IN WHICH THE BUILDING ELEMENTS LISTED IN TABLE GO I ARE OF NON COMBUSTIBLE MATERIALS, EXCEPT AS PERMITTED IN SECTION G03 AND ELSEWHERE IN THIS CODE. I CHAPTER 5 GENERAL BUILDING HEIGHTS * AREAS FBC TABLE 503 ALLOWABLE HEIGHTS AND BUILDING AREAS ALLOWABLE PER CODE PROPOSED TYPE OF CONSTRUCTION VB VB MAXIMUM HEIGHT 2 STORY 2 STORY BUILDING AREA 7,000 S.F. 89G 5.F. (COTTAGE) IM P VIOU S AREA5: ER EXI5T1 NG— BLDG 1,442 5QFT DRIVEWAY 586 5QFT TOTAL 2,028 5QFT NEW— BLDG 181 1 5QFT NEW RE5ULT5 IN REDUCTION OF IMPERVIOUS AREA BY 2 17 5QFT OR I I %. I e OCEAN f RO NT �.5 OG7 FAGE ADDITION 067 BEACH AVENUE, ATLANTIC BEACH, FLORIDA 32233 DRAWING LIST ARCH ITECTURAL A300– COVER SHEET A30OA– 5URVEY5 A300B– 5URVEY5 A301– 15T FLOOR PLAN5 A302– 2ND FLOOR PLANS A303– ELEVATION5 * 5ECTION5 A304– RCP's, FRAMING PLAN5, 4- STAIR PLAN AND SECTION A305– WALL 5ECTION5*- DETAIL5 A30G– DOOR * WINDOW IfLEVATION5 GENERAL NOTES: 1. ALL PRODUCT5 SELECTED BY CONTRACTOR MUST BE INCLUDED IN THE FLORIDA PRODUCT APPROVAL L15T (APPROVAL INFORMATION TO BE 5UBMITTED UPON REQUE5T BY CONTRACTOR) AND MUST BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'5 REQUIREMENTS. 2. PRODUCTS THAT 5HALL CONFORM TO NOTE NUMBER ONE INCLUDE (BUT NOT LIMITED TO) STEEL REBAR, WOOD 5TUD5, METAL FLA5HING, PEEL * 5TICK M015TURE BARRIER, PAINT, VAPOR BARRIER, , CA5T IN PLACE CONCRETE AND DOOR5. 3. CONTRACTOR 15 TO SUBMIT 5AMPLF-5 OF ALL 5ELECTED PRODUCT5 TO OWNER FOR APPROVAL. 4. CONTRACTOR 15 TO CONTACT THE ARCHITECT IMMEDIATELY IF THERE ARE ANY D15CREPANCIE5 BETWEEN PLAN5, 5ECTION5 AND / OR DETAIL5. 5. PLEASE NOTIFY ARCHITECT OF ANY D15CREPANCIE5 BETWEEN ALL DISCIPLINES' DRAWING5. G. PLEASE NOTIFY ARCHITECT IF ANY CLARIFICATION DRAWINGS 5HOULD BE REQUIRED DURING THE CON5TRUCTION PROCE55. FIRE ALARM 5Y5TEM NOTES: 1. AUDIBLE AND V15UAL NOTIFICATION WILL BE ADDED PER NFPA 72 REQUIREMENT5. 2. CONTRACTOR WILL BE REQUIRED TO CONTACT FIRE MARSHAL TO COORDINATE ACCEPTABLE FIRE ALARM 5Y5TEM. CRO 5 HATCH INDICATES EXI5TING PAVING — — — — PROPERTY LINE- - — I i Lu R ann❑❑ani!coconan❑onnaa❑cn❑❑ccan❑ �'aoannaaTT oaanpG❑G❑non ff�� - a.n❑ncc_an :.�._._. ----_I V'' I.,V" F. V _ .. _❑c❑❑cG❑GcaanGnnannon❑GG❑❑ U I nooboa0Aaogn anon .aacnnon0000nga ¢ _ = — {" Fj z-l6nnnn❑aGna ❑n naa❑aan a a c❑❑.aa'p + - -.-. LL1I j--- I_ � _ ._I � a 0.1110.1 a aca ❑an❑aca❑:acaoaa ❑c 1 + _. �.�__._J � ��i❑oo❑aoa�+oa❑ anan❑onaannaooaocI— ❑ ❑❑o,❑aa ❑r,c❑❑❑❑naoa❑aa❑4-4 ...... no �_Ynn❑❑n❑❑a❑an 10.0.1❑a'❑G00 nnpnnn CCS ' 1 (L ❑pnaaaaC nnn 0.a naanaaaaan GnnC."• ,, ,... ._—_{_ ' _. - I a or »flotioB- ... 0.000n nonI �— n❑aGaan ❑an 1 aaa = .. i; / f1 0000eGoo❑n ❑❑a _ EXIST(.NG TW I n a. E,,,J aaacnoaann on -._ _ ,�.. 0.1 as❑onan�❑a ❑�"> - -,I_-� 1� an❑aaaan— PROPO5ED T STORY HOME ❑an0nnnagqa nn ❑n..m r n0000000 qn❑❑GG O STORY COTT GIf � 4]np 0.0.1110.❑n ❑❑n ri — L EXISTING r I r( �,� WALKWAY NEW FENCE -- ------ — — — _ — — — — — (5ELECTED BY OWNER) PROPERTY LINE 1 0'-7" 32'–O" ,5'–G" G4'-1 " 141 '-10 112 ARCH ITECTU RAL SITE PLAN SCALE: 3/32°=1 {-0" NORTH 77 N 0 N z 1.L 7 Q o 0 0 UJ _ Q 00 U Z f� W d w lu Z lu 0 lu t _ Lu CD 0 u COVER SHEET ARCHITECTURAL 5ITE PLAN z O Lu u.J D T) Q D w D z D O V > LLJ Z Lu LrL 0.W (fin _ w N �'9 Q COVER SHEET ARCHITECTURAL 5ITE PLAN C:) Q0 C) c� c� FOUND P.K. NAIL & DISK LOT 9 (A DURDEN PLS #1674 FOUND 112" IRON PIPE WITNESS L.B. #6645 155.22' (MEASURED) I 11 44 2' �';i' ' '' � i' � ` � Z Z CD LOT (9 2 STORY FRAME (Z) BEACH HOUSE t1a DECK 41 111073 (MEASURED) RESIDENCE FOUND 1/2"IRONyl bo) z (NOT INCLUDED) PIPE k�l 0'. -�� --' REF. COR. L.B. 1#166-9 �-, __9 0 4' N8,3'1 8'21 "E 253-20' WOOD 2ND STORY WOOD WALK ---i P _)FF�CE rn k2 GARAGE APARTMENT #1073 0.25' OVER LINE 200. 00' (PLAT) WOOD K --1 -0 (NOT SHOWN) WOOD F'Elvc,- 44.2' X., x STEPS C,�2,8' 6' WOOD FENCE 3.20' 1.0, N�, NOT SHOWN) P)X x N, x (24" EAVES PA114 Q:) OF OLD 24" 55,6' 1 REMAINS CONCRETE BULKHEAD CAP ' SECOND STORY --i (LEANINC) Lo rr) 0 WOOD WALK rr, t\-) t 0 kb��i b) 2 STORY FRAME t, To WOOD , < Vl, d 1\lb� x N. 5D I , , 1, 1 1 '1,- k� BEACH HOUSE / XQ\ x '10 - 47.6 TIE 1ST STORY BRICK PORCH N3 XQ D x CONCRETE DRIVE &9 100' 2ND STORY WOOD DECK RESIDENCE #1067 (A Q��b WOOD � & PARKING rn T I') CONCRETE AIC PADS FINISH FLOOR ELEVATION (16.02) o WALK WOOD WALK UNDER RENOVATION 0 < SECOND STORY x N� q J,�l Q% rri Q) OVERHANG x �nl 0,9' X 8-0, 61 E:! Ql Q 65.6' XQ-lb 115.0) t,� 3 5.6 (15.4) 54.08' ��o �j TRB 4' WOOD FENCE MEANDERS AND LEANING WPP 01\) > Z �x wpp & X(WOOD FENCE MEANDERS AND LEANING 0.5' '�(12- EAVES 200.00' (PLAT) NOT SHOWN) S8,3'18'21"W 254.08' o f 11 1 QD z IT, (MEASURED.) c _T 1 61 2LOT 6 ---i C) C) FTI QD N N 200.00' (PLAT) rri FTJ C) Q� c� LOT 5 SURVEY V13004 SCALE: I/JG`=I'-0` --------------------------------- r1i c� LOT 9 FOUND P.K. NAIL & DISK co DURDEN PLS #1674 c: FOUND 112" IRON PIPE T WITNESS L.B. #6645 155.22' (MEASURED --------------- O 44.2' Q) LOT 8 2 STORY FRAME BEACH HOUSE fl) 11 N) L� 16) FTJ -N (MEASURED) RESIDENCE #1073 4 41, ,1, (NOT IYCLUDED) C) NB3* 18'21 "E 253.20 cu 41 WOOD --I P rr, 'H GARAGE APARTMENT #1073 8' N �)-_ENCE 200.00' (PLAT) WOOD (NOT SHOWN) FENCE F-1-1 0 44.2' 6 X,\ 1.3' %A L10.8, 6' WOOD FENCE PALM al xe. 24" EAVES NOT SqOWN) 0al Rol 40, H 2H .......... FOUND 112� IRON PIPE L.B. #6515 —3.4' TO FACE OF OLD CONCRETE BULKHEAD WOOD "X Il FOUND 112 IRON PlkE REF.COR. L.B #66961 ykl 3.1 ' TO FACE 0 OLD I x CONCRETE BUL HEAD x x1l) C) Co C) C) r1l N z 0.9 "imliFOUND N3 (-,I t.D. 50 � 1 REF.COR. L.B #66961 3.1' TO FACE 0 OLD I C) (V 770 CONCRETE BUL HEAD 4)) 0 Q 4 x x x`21 til ,4 x C) C) < Q) z 00 U -i < D z U -i 0 lu > < 0 O Lu CD 0 a FOUND 112 IRON PIPE N l dol 1l X 1'1 L.B. #6515 I LI II Fq Q'I QD sl FOUND 112" IRON LLJ D o N pIpE, REF. COR. L.B. 16696 (s) 3.4- 70 FACE OF OLD H PROPOSED PLAN (S-) BULKHEADCONCRETBULKHEADx `1��1 I , (s) u� 2l I N 43.20 C) x xk�v 01) i > I REMAINS OF OLD 24- CAP -- CONCRETE BULKHEAD (LEANING) ,< Q __j I F I I I I bi .. ___ .. ___n �__, I I I i, i ..................... FRAME 2 'MRY F ................ -,WOOD ri ..........t�k x a itQ11 '+/.b /114 BEACH .HOUSE X #7067 0 WOC ------- H. CONCRETE AIC .3,z A-, 54Z (16.02) WAL _LfADS FINISH FLOOR ELEVATION cy) -REiNOVATION FD! 0) H (15 4 FT] - kk� 14 "Ll .(15.3) m-.1— .......... '�NDL�ENING 4 WOOD FENCE P k�b�� TRR > x b wpp Wo__oDFENCE MEANDERS AND LEANING Z 712" EAVES 200.00' (PLAT) C:0 NOT SHOWN) S83'1 8'21 254.08 Qi I (MEASURED) LOT 6 r _rl 0 N 0 200.00' (PLAT) I nT rz ------------------- 7-7— WOOD ,WALK. , rIQ 2) SURVEY WIT 004 SCALE: 1/1611=11-011 0.9 "imliFOUND Fri (-,I 54.08' ! Z� Xyl �1l Cp�l REF.COR. L.B #66961 ------------------- 7-7— WOOD ,WALK. , rIQ 2) SURVEY WIT 004 SCALE: 1/1611=11-011 -"-t+OVIVAL HIGH WATER LIME ELEVATION (9-38) NAVE) 111 ro) \ � C y ho `60l .0 51 Q11 1� l 0.9 "imliFOUND 112" IRON PI 54.08' ! Z� Xyl �1l Cp�l REF.COR. L.B #66961 3.1' TO FACE 0 OLD I C) (V 770 CONCRETE BUL HEAD 4)) 0 x211 4 x x x`21 til ,4 x C) uj CD < Q) z 00 U -i < D z U -i 0 lu > < 0 O Lu CD 0 a N l dol 1l X 1'1 t1 LI No Fq Q'I QD sl LLJ D o N (s) Lu 0 H PROPOSED PLAN (S-) -"-t+OVIVAL HIGH WATER LIME ELEVATION (9-38) NAVE) 111 ro) \ � C y ho `60l .0 51 Q11 1� l '--'-'U'VAL HIGH WATER ELEVATION (9.38) LINE NA VD x0 0 A x0l 0.0 I& x OZ C) (V 770 of 0 x211 4 x x x`21 til ,4 x MtAN HIGH WA7ER LINE ELEVATION (1-97) NAW) > X0sloil. X0 > x of x x N07F.• THE MEAN HIGH IS NOT A BOUNDARY LINE LINE PROPERry. NIS Ne FOR THIS WITHIN A �EZ R PROPERTY LIES AREA -N9URSHMENT CONTROL OU"DED LINE BY THE EROSION COUNTY RECORDED FLOR10A IN DUVAL MtAIV HIGH WATER ELEVA7701,, 1.97ERI LINE ( VAD> '--'-'U'VAL HIGH WATER ELEVATION (9.38) LINE NA VD CO Cf) 0 A x0l 0.0 I& x OZ C) (V 770 of 0 x211 4 x x x`21 til ,4 0 C) uj CD < Q) z 00 U -i < D z U -i 0 lu > < Lu CD 0 l dol 1l X 1'1 t1 LI 1,51 Q'I sl LLJ D � MtAN HIGH WA7ER LINE ELEVATION (1-97) NAW) > X0sloil. X0 > x of x x N07F.• THE MEAN HIGH IS NOT A BOUNDARY LINE LINE PROPERry. NIS Ne FOR THIS WITHIN A �EZ R PROPERTY LIES AREA -N9URSHMENT CONTROL OU"DED LINE BY THE EROSION COUNTY RECORDED FLOR10A IN DUVAL MtAIV HIGH WATER ELEVA7701,, 1.97ERI LINE ( VAD> CO Cf) 0 A x0l 0.0 F >x fo k. o ox x of al NOTE" THE MEAN HIGH WATER LIN, IS NOT A BOUNDARY LINE FOR PROPERTY. THIS PRop&y7y THIS WITHIN A &C14 RENLIES AREA BOUNDEDDED oURISHMEAfT BY THE EROSION CONTROL LINE RECORDED IN DUVAL COUNTY RORIDA 5UPIVEY5 300 CO Cf) 0 C\l OZ C) (V 770 0 < U -J LL_ 3:� Q) < 0 C) uj CD < Q) z 00 U -i < D z U -i 0 lu > < Lu CD 0 5UPIVEY5 300 O tu Lu LI LLJ D � (s) Lu 0 (S-) (s) > U -i > tu ,< Q __j (L/ Lu D J) (s) (L CL 5UPIVEY5 300 O f.f.l. = 15.55'--\ F.F.E. = 16.02' CUT SURPLUS FROM EXCAVATION: A - FILES, 33.0'x 3.14 x .5832 G7.3 I`T2 / 27 = 2.5 YD3 13 - 5LAD 10.0' x 28.0'x .563 = 1 G3.2 / 27 = G.0 YD3 C - GRADE 13EAM5 90 Lf x 2.0'x IS/ 27 = 10.0 YD3 TOTAL YARDAGE = 18.5 YD3 16 - - - - - - - - - - - 1 A - - I - - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - T - - - - - - - --- - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - - - - 12 = - - --------- - ----- - - - - - - - - - C) 0-/ (14.9) =77 - - - - --------------------------- - - - - - - .. . .... -------------------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10 8 UJ (15.69) 15 (15.27) -- - - - - - - - - - - - - - - - - -- - (0(15.13) < (15.0) (D (15.19) 7 vj 6 4 Luz (14.96) - - - - - - - - - - - - - - - - - - - - - --- - - - - - - - - - - --- - - - - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - -- 7 - - - - - - - - - - - - 2 44 - - - - - - -++ (14.48) (D (15.9) (D (14. 1) Xi TqE 'A4EAN HIGH '44 7 -ER LIN NOT A BOUNDARY / ovF PROPERTY. FOR TyQ Z - THIS p �E -AGN ROPER7-K LIES AREA 6�'��OORISHm&VT , THE CON Or qp- Z'o EPOc10N -"i;V CLjUA'7-,' C "'ED IN D SITE SECTION Lu %N300E/ SCALE: I/10=1' -O" AVG fINI5H GRADE EL. = 1 5. 1 1' 12 12 Jj I L Ju r Tr F7 L 2 AVG GRAD 00pF SCALE: N.T.S. E ELEVATION ROOF BEARING EL. = 1 7-8" A.F.F. 30 HIGH GUARD RAIL WINDOW 51 LL EL. = I O' -G" A.F.F. 5fCOND FLOOR EL. = 6-8` A.E.F. WINDOW SILL EL. = 2'-10" A.F.F. fIN15H FLOOR EL. = 15-55' j ->< c� cl L FOUND P.'1- NAIL & DISK IR F)IIOEN # 1 PLS 6, 7 4 RON PIPE of F JR- op, 01 1 - FOUND I E3 IJ WITNESS E.P. #564,-) 155.22 D) #65' (VEASURE Q: 2 -STORY FRAME LOT a WOOD BEACH HOUSE DECK RESIDENCE J1073 FOUND OVEASURED) (N07 NCLUDED) 10' x 10' GRID OVERLAY PIPE x 6 Fj 2 C) -7 ovoOD GARAGE APAP7VClp,,tT _4 10 8' WOOD 200.00' (PLAT) F&g-' • (po-' Q11 5) -- - Alt X% 4 EAVES NOT SH00VIV/1 6' WOOD Ft`,qCE � _7 �7 16) xe -7 1.77 XL 12 asI I if 9EVAINS OF OLD 24" CAP- Kk!'E4D X --K-, L x XQI WOOD N� --j x WO X �,VA N X) V4 TjOI I W FLOrl ('g 0 xk,\ 1 < !� FT N, J'iRo�.' P! 3. ND Q 7.7 4' W(01.', FENCE MEANDERS AM- 7ACE Ok OLD o Q REF,GOR. L.Btl # '.0) To x TRS V/pp Q1 FLNCE MEAND 7RS' )X (D X AND LEANING 3ULkHE4D Z-� x X11 x 200.00' (P L A T) Q\ ;271 EAVES SHOWN)"2 - SBY W 5 (M EA z-3 URL . D) r7-1 FT`�<O GARAGE & APT FOOTPRINT C) QD N Z r- 200.00 'PLAT) IF') N AVG HEIGHT SURVEY --k - -300Dj;15CALF-- 7 -1 M 1'-9 FILL RQ'D ON 51TE FOR 5POIL5 REMOVAL: A - 5HED FOUNDATION EXCAVATION 101-011 x 8'-0" x 2'-0" = I GO FT -3 / 27 = 5.9 YD3 13 - CONCRETE DRIVE REMOVAL G80 51' x .5 = 340 / 27 = 12.G YD3 TOTAL YARDAGE = 18.5 YD3 - - - - - - - - - -------------16 14 12 - - - - - - - - - - - - - - - -- 10 -------- - - 2 lJ (14.2) 12 (15.5) �-!MEAN (14.5) (9(15.0) 77 C) 0-/ (14.9) 14 (14.7) UJ (15.69) 15 (15.27) (15.64) (0(15.13) < (15.0) (D (15.19) 7 vj (15.3) Luz (14.96) (15.4) (D(14.88) of (15.9) 20 (14.48) (D (15.9) (D (14. 1) 317.34 / 21 = 15.11 ave I IL ---- -- ---- RPM 5URVEY5 HIGHVJA TE '" ' ELEVATION(7.971` M 0 �-!MEAN J­ ry It- 77 C) 0-/ (D 0 LL - UJ � (1) Lu < O ox Luz w Lu > < of x Lu CD 0 TqE 'A4EAN HIGH '44 7 -ER LIN NOT A BOUNDARY / ovF PROPERTY. FOR TyQ Z - THIS p �E -AGN ROPER7-K LIES AREA 6�'��OORISHm&VT , THE CON Or qp- Z'o EPOc10N -"i;V CLjUA'7-,' C "'ED IN D 5URVEY5 M 0 ry It- 77 C) 0-/ (D 0 LL - UJ � (1) Lu < O Lu Luz w Lu > < Lu CD 0 5URVEY5 0 Lu D (n (s) LLJ (s) Lu 0 0 D (s) tri 0 (S) > LLJ (V LLJ a-. Lu C11 C9 CV C) 5URVEY5 3 '� HURRICANE STRAPPING KEY - 1ST 30 11 SCALE: 3/32"= P-0" CONSTRUCTION DUMF5TER TO BE NEW GRA55 BLOCK PAVING 0 PROPERTY LINE LOCATED IN PROPOSED PARKING AREA (SELECTED BY OWNER) (y) n/ it- F 0 0 0 13 0 0 01 0 0 0 0 0 0 0 0 Ll EX15TING 5TAIRL < z < El 0000[03000� DE01000100000or- 0 0 LLJ El 0 El El 0 Eli 0 110 El 0 0 11 "1 0 0 El 0❑ i j 0 Lj 00 00 E] LL 0 00 E3 � El 110 000000 000000000000 000❑ Lu ID El E-1 z Lu Lj Ll [1 0 11 0 El 0 El D 11 11 11 0 0 11 11 El El J E 11 z w0 F-! D 0 El El El 0 0 n 7 1-11-117 F7'7'❑r-1 E 321-011 5 I -Gil 'u > < - El El El El Dj ID F -I ol L 0 El 0 El El E] F -I El i L, LJ F7 cl 0 Lj o o Ei _0 Li 13 A —77 -7 0O E] 0 [] E] 0 0 E] F 1 71 5IL7 El D, I- D 1 1 1 5 or [:j El [1 0 D El 0 El 0? 1E M M 0; El El 11 11 1:1 11 El 11 [1 0 El Ll D El El PS 17 Ll El 0 0 El Ej ID El F � L 11 El El 1: - ------- --------- (s) El 0 El L' El El 0 0 1:❑1 0 E❑I E-4 7 11❑ GARAGE STORAGE - uA& Lu l- C\j El El \,A30E —b 0 01 0 IF] NEW CONTINUOUS FENCE (SELECTED BY OWNER) 3 2'-Ojl 5'-6il ? PROPERTY LINE FIRST FLOOR PLAN Wo 11 SCALE: 114"= I' -C)" QUICK -Tiff HURRICANE STRAP (s) (OR EQUAL} @ 48" O.C. (MAX) 0 AND AT 51DE5 Of OPENINGS • • • (S-) 3 '� HURRICANE STRAPPING KEY - 1ST 30 11 SCALE: 3/32"= P-0" CONSTRUCTION DUMF5TER TO BE 0 LOCATED IN PROPOSED PARKING AREA (y) n/ it- 77 < z < 0 0 LLJ C) 0 C) Lu ID < z Lu < z w0 'u > < - fir -1 f f IIIH Hh U:fA L'V__J',J I_ q w77 CD 0O t7rm -i _2§1 L 73 — — -- — — CON.5TRUCTION R.R. TO BE EROSIONt 51 LT CONTROL TO B 05ION CONTROL TO BE SCREEN W1 HAY TUBES EXISTING FENCE W1 SILT SCREEN CONSTRUCTION IN EXISTING HOUSE 16" CONCRETE GRADE BEAM THICKENED SLAB EDGE 321-011 SCALE: 114"= P-0` QUICK -TIE HURRICANE STRAP 'O"' EQUAL) @ 48" O.C. (MAX) AND AT 51DE5 Of OPENINGS • ON 1) A HURRICANE STRAPPING KEY - 2ND SCALE: 3/32"= P -O" 5 -'\CONSTRUCTION SITE PLAN 3O I I -SCALE: 3/32"= P-0" I 51-01 0) o 00 n LT. 13 0-) (D (n c4 U c: iT-- V) 15T FLOOR, H U RRI CAN E STRAPPING, CONST 51TE PLANS A301 0 C\l N (y) n/ it- 77 < z < 0 0 LLJ C) 0 C) Lu ID < z Lu < z w0 'u > < - Q) I_ q w77 CD 0O 15T FLOOR, H U RRI CAN E STRAPPING, CONST 51TE PLANS A301 0 Lu (s) Ln Lu LLJ (s) Lu 0 (S-) > Lu z Z ry LLL (ID IT 15T FLOOR, H U RRI CAN E STRAPPING, CONST 51TE PLANS A301 2 Q gaol i EX15TI N . 5'-G'1 a 20'-G" 3'-01 3'-G" 4'-01 19 321-011 5'-G"' SECOND FLOOR PLAN 021 5CALE: 1/4"= 1'-0" STANDING SEAM METAL ROOF W/ WATERPROOF MEMBRANE ON 5/8" T*G DECKING OVER PRE -FABRICATED ROOF TRUSSES (IN5TALL 2" RIGID IN5ULATION) 30-011 ROOF PLAN 302 5CALE: 1/4"= P-0" 5TAI R 4" WOOD STUD WALL @ I G" Q.C. W/ WOOD / I SHAKE 51DING ON 112" PLYWOOD 5HEATHING WITH WATER RE515TIVE BARRIER �I x WITH CONT. R-9 BATT IN5ULATION (1 /2" F; GWB INTERIOR 51DE OF WALL (PAINT) I QUICK -TIE HURRICANE 5TRAP (OR EQUAL) u I1\15TALLED PER CODE REQUIREMENT5 P.T. 2X4 51 LL PLATE (ATTACH A5 REQUIRED BY QUICK -TIE STRAP) I XG FIN15H BOARD TRIM (PAINT) CONT. P.T. 2XG BOARD TRIM (CONT. BACKER ROD AND 5EALANT d TOP * BOTTOM) GRADE APRON FLA5H 1 NG - ,; O 3000 P.5.1. FIBERGLA55 REINFORCE 4" CONCRETE TURN -DOWN 5LAB ON COMPACTED TREATED FILL CONTINUOU5 VAPOR BARRIER 74""'N WALL SLAB DETAIL V3021 5CALE: I -1/2"=1'-0" 30 HIGH GUARD RAIL FIN MOUNTED 50LID � GLA55 DUAL 5WI NG D 112" PLYWOOD DECKIP FLOOR TRU55E5 @ P.T. 2x8 BLOCKING BE 112" PLYWOOD DECD 5TRINGER CUT FROM 2x8 @ 12" O.C. CONT. METAL FLA5HIN (PAINT) ON CONT. CLE, I X8 TRI M BOARD (PAI I` HEADER CUT FROM P.• P.T. I X BOARD TRIM (1 P.T. I X BOARD TRIM (I BACKER ROD AND 5E/ (2) P.T. 2X4 HEADER V 112" PLYWOOD 5PACEF 50LID CORE FIBERGLA GARAGE DOOR L V 4--114 1 1 1 11\V 1\L/\JI 2 :� SECOND FLOOR PLUMBING PLAN 3021 5CALE: 1/4"= 1'-0" 5"1 J� JULIET BALCONY DETAIL 5CALE: I -1 12"= P-0' R-30 BATT INSULATION 5TANDING 5EAM METAL ROOF W/ WATERPROOF MEMBRANE ON 5/8" TSG DECKING OVER PRE -FABRICATED ROOF TRU55E5 5IMP50N H4 HURRICANE CLIP (OR EQUAL) P.T. 2XG BOARD TRIM (CONT. BACKER ROD AND SEALANT TOP * BOTTOM) PAINT UNDER51DE OF TSG DECKING (2) P.T. 2XG HEADER CONT. METAL FLA5H I NG (PAINT) ON CONT. CLEAT P.T. IX4 ON P.T. IXG V FASCIA BOARD (PAINT) QUICK -TIE HURRICANE 5TRAP (OR EQUAL) IN5TALLED PER CODE REQUIREMENTS 4" WOOD 5TUD WALL @ I G" O.C. W/ WOOD 5HAKE 51DING ON 1/2" PLYWOOD 5HEATHING WITH WATER RESI5TIVE BARRIER WITH CONT. R-9 BATT IN51JLATION (112" GWB INTERIOR 51DE OF WALL (PAINT) ROOF DETAIL 5CALE: I- 112"= P -O" R-30 BATT IN5ULATION STANDING 5EAM METAL ROOF W/ WATERPROOF MEMBRANE ON 5/8" TSG DECKING OVER PRE -FABRICATED ROOF TRU55E5 SIMP50N H4 HURRICANE CLIP (OR EQUAL) P.T. 2XG BOARD TRIM (CONT. BACKER ROD AND 5EALANT TOP * BOTTOM) PAINT UNDER5IDE OF T> -G DECKING (2) P.T. 2XG HEADER CONT. METAL FLA5HING (PAINT) ON CONT. CLEAT P.T. I X4 ON P.T. I XG FA5CIA BOARD (PAINT) QUICK -TIE HURRICANE 5TRAP (OR EQUAL) INSTALLED PER CODE REQUIREMENT5 4" WOOD 5TUD WALL @ I G" O.C. W/ WOOD 5HAKE 51DING ON 112" PLYWOOD SHEATHING WITH WATER RE515TIVE BARRIER WITH CONT. R-9 BATT IN51JLATION (112" GWB INTERIOR 51DE OF WALL (PAINT) ROOF DETAIL 5CALE: I -1 12"= P -O" 0 � 51-011 31_QII f I_y�ll 71_}^11 31_�j 11 51 -Gil ON INEW 2" CONTINUOUS z < 0 IH IG H WOOD, RAI LI (PAINT) w Q Q 0 I LLJ U z _ Ln C ^ V 1 1 '-411 ! 0.1 3!- 1" 4, 13 N U.Jo tu Q Q u 7 w 0 -- Z O BEDRO DM -! LU = CL05ET L? — o _ N Lu " KITCHEN / LIVING n ! m w ! 01. O_ — y.._.......>v. 1t00(10 , n (�7 — a 20'-G" 3'-01 3'-G" 4'-01 19 321-011 5'-G"' SECOND FLOOR PLAN 021 5CALE: 1/4"= 1'-0" STANDING SEAM METAL ROOF W/ WATERPROOF MEMBRANE ON 5/8" T*G DECKING OVER PRE -FABRICATED ROOF TRUSSES (IN5TALL 2" RIGID IN5ULATION) 30-011 ROOF PLAN 302 5CALE: 1/4"= P-0" 5TAI R 4" WOOD STUD WALL @ I G" Q.C. W/ WOOD / I SHAKE 51DING ON 112" PLYWOOD 5HEATHING WITH WATER RE515TIVE BARRIER �I x WITH CONT. R-9 BATT IN5ULATION (1 /2" F; GWB INTERIOR 51DE OF WALL (PAINT) I QUICK -TIE HURRICANE 5TRAP (OR EQUAL) u I1\15TALLED PER CODE REQUIREMENT5 P.T. 2X4 51 LL PLATE (ATTACH A5 REQUIRED BY QUICK -TIE STRAP) I XG FIN15H BOARD TRIM (PAINT) CONT. P.T. 2XG BOARD TRIM (CONT. BACKER ROD AND 5EALANT d TOP * BOTTOM) GRADE APRON FLA5H 1 NG - ,; O 3000 P.5.1. FIBERGLA55 REINFORCE 4" CONCRETE TURN -DOWN 5LAB ON COMPACTED TREATED FILL CONTINUOU5 VAPOR BARRIER 74""'N WALL SLAB DETAIL V3021 5CALE: I -1/2"=1'-0" 30 HIGH GUARD RAIL FIN MOUNTED 50LID � GLA55 DUAL 5WI NG D 112" PLYWOOD DECKIP FLOOR TRU55E5 @ P.T. 2x8 BLOCKING BE 112" PLYWOOD DECD 5TRINGER CUT FROM 2x8 @ 12" O.C. CONT. METAL FLA5HIN (PAINT) ON CONT. CLE, I X8 TRI M BOARD (PAI I` HEADER CUT FROM P.• P.T. I X BOARD TRIM (1 P.T. I X BOARD TRIM (I BACKER ROD AND 5E/ (2) P.T. 2X4 HEADER V 112" PLYWOOD 5PACEF 50LID CORE FIBERGLA GARAGE DOOR L V 4--114 1 1 1 11\V 1\L/\JI 2 :� SECOND FLOOR PLUMBING PLAN 3021 5CALE: 1/4"= 1'-0" 5"1 J� JULIET BALCONY DETAIL 5CALE: I -1 12"= P-0' R-30 BATT INSULATION 5TANDING 5EAM METAL ROOF W/ WATERPROOF MEMBRANE ON 5/8" TSG DECKING OVER PRE -FABRICATED ROOF TRU55E5 5IMP50N H4 HURRICANE CLIP (OR EQUAL) P.T. 2XG BOARD TRIM (CONT. BACKER ROD AND SEALANT TOP * BOTTOM) PAINT UNDER51DE OF TSG DECKING (2) P.T. 2XG HEADER CONT. METAL FLA5H I NG (PAINT) ON CONT. CLEAT P.T. IX4 ON P.T. IXG V FASCIA BOARD (PAINT) QUICK -TIE HURRICANE 5TRAP (OR EQUAL) IN5TALLED PER CODE REQUIREMENTS 4" WOOD 5TUD WALL @ I G" O.C. W/ WOOD 5HAKE 51DING ON 1/2" PLYWOOD 5HEATHING WITH WATER RESI5TIVE BARRIER WITH CONT. R-9 BATT IN51JLATION (112" GWB INTERIOR 51DE OF WALL (PAINT) ROOF DETAIL 5CALE: I- 112"= P -O" R-30 BATT IN5ULATION STANDING 5EAM METAL ROOF W/ WATERPROOF MEMBRANE ON 5/8" TSG DECKING OVER PRE -FABRICATED ROOF TRU55E5 SIMP50N H4 HURRICANE CLIP (OR EQUAL) P.T. 2XG BOARD TRIM (CONT. BACKER ROD AND 5EALANT TOP * BOTTOM) PAINT UNDER5IDE OF T> -G DECKING (2) P.T. 2XG HEADER CONT. METAL FLA5HING (PAINT) ON CONT. CLEAT P.T. I X4 ON P.T. I XG FA5CIA BOARD (PAINT) QUICK -TIE HURRICANE 5TRAP (OR EQUAL) INSTALLED PER CODE REQUIREMENT5 4" WOOD 5TUD WALL @ I G" O.C. W/ WOOD 5HAKE 51DING ON 112" PLYWOOD SHEATHING WITH WATER RE515TIVE BARRIER WITH CONT. R-9 BATT IN51JLATION (112" GWB INTERIOR 51DE OF WALL (PAINT) ROOF DETAIL 5CALE: I -1 12"= P -O" 0 � m ON z IL/ IL z < 0 770 O Q w Q Q 0 I LLJ U z J C ^ V Q Lu z U.Jo tu Q Q u 7 w 0 -- Z O 2ND F;PO 012 PLANS,OF PLAN, * DETAILS A302 z O tu CL LU Lu n w () tLS O_ D n (�7 — z IL/ RLy W c0 �J tti �9 Q cN n 2ND F;PO 012 PLANS,OF PLAN, * DETAILS A302 COTTAGE BUILDING SECTION 031 SCALE: 114"= 1'-0" ROOF BEARING EL. = 17-8" A.F.F. 30 HIGH GUARD RAIL AC WINDOW 51LL EL. =: 10'-G" A.F.F. 5ECOND FLOOR EL. = 6-811 A.F.F. WINDOW 5ILL EL. = 2'-10" A.F.F. fIN15H FLOOR EL. == 0'-O" 3 COTTAGE WEST ELEVATION M! SCALE: 114"= 1'-0" ROOF BEARING EL. �� 17-8" A.F.F. WINDOW 5ILL EL. = 110'-G" A.F.F. SECOND FLOOR EL. II = 81-61(A.f.f. WINDOW 5ILL EL. = 112'-10" A.F.F. f I N 15 H FLOOR If L. =11 01-011 42" HIGH GUARD RAIL jL WINDOW 51 LL EL. = 10'-G" A.F.F. 5ECOND FLOOR EL, = 6-b" A.F.F. it I t —5� f I N15H FLOOR EL. = 0'-0" 5 COTTAGE SOUTH ELEVATION M7 SCALE: 114"= P -O' 30' HIGH GUARD RAIL ELEVATION MATERIAL KEY INDICATE5 5TANDING SEAM 0 METAL ROOF N N INDICATE5 WOOD 5HAKE 51DING (MATCH EXISTING} (Y) < It INDICATE5 WALL MOUNTED 0 IL/ EXTERIOR LIGHTING (MOUNTED 0 @ A MINIMUM Of 0-0 A.f.f.) AL ROOF BEARING EL. = 17-b" A.E.F. �lff WINDOW SILL EL. = 10'-G" A.F.F. 5ECOND FLOOR EL. = &-b" A.F.F. WINDOW 5ILL EL. = 2'-10" A.F.F. f IN 15H FLOOR EL. = 01-011 \'-w COTTAGE BUILDING SECTION >03IF 5CALE; 1/4"= 1'-0" ROOF BEARING EL. = 17-6' A.f.f 30 HIGH GUARD RAIL ,\ WINDOW SILL EL. = 121-411 A.F.F. WINDOW 5ILL EL. = 10'-G" A.F.F. SECOND FLOOR EL. = 8'-8" A. F. F. WINDOW 5ILL EL. = 2'-10" A.F.F. FINISH FLOOR EL. = 01-011 4 COTTAGE EAST ELEVATION Ml SCALE: 11411 = 1'-0° COTTAGE NORTH ELEVATION 303/f5CALE: I/4"— iJ-011 OC ROOF BEARING EL. = 17-b" A.F.F. 42" HIGH GUARD RAIL 41UWINDOW 51 LL EL. = 10'-G" A.F.F. \110 5ECOND FLOOR EL. = 8'-b" A.F.F. AU WINDOW 51 LL EL. = 2'-10" A.F.F. \Iffl f IN15H FLOOR EL. = 01-011 COTTAGE f LEVATION5 DUILDING SECTIONS M 0 N N CL/ (Y) < It 77 0 IL/ 0 o U -J Q) 0 Lu ED u 17 - Lu z LLJ 0 'u > < T- Q) Lu 0 COTTAGE f LEVATION5 DUILDING SECTIONS 0 cnN Gl LLJ D z 0) Lu 0 (S) (S) > — Ill > Lu (S) [L U-3 D— T) co co LLJ NLD Q COTTAGE f LEVATION5 DUILDING SECTIONS 1 g SECOND FLUOR REFLECTED CEILING PLAN U3041 5CALE: 11411= 1'-0" FIRST FLOOR REFLECTED CEILING PLAN 5CALE: 114"= 1'-0" (2) P. T. 2X8 JOIST METAL HANGER - ATTACH STAIR TRINGERS TO 8X8 POSTS (BOTH SIDES OF STRINGERS) REI~ _EGTED CEILING PLAN LEGEND O RECE SED DOWN -LIGHTING N N 5U5P :NDED f CEILING FAN * LIGHTING FIXTURE �c WALL MOUNTED LIGHTING o WALL FOR MOUNTED EXTERIOR LIGHTING (SEE ELEVATIONS IOUNTING HEIGHTS) o EXHAUST FAN * DOWNLIGHT ® DECORATIVE PENDANT LIGHT FIXTURE Q BATHROOM WALL SCONCE Lu EDU NOTES: 1. ALL CEILINGS TO BE G.W.B. (PAINT) ATTACHED TO BOTTOM OF ROOF AND FLOOR STRUCTURE UNLESS OTHERWISE INDICATED ON PLANS. FRAMING NOTES: 1) FRAME AS NEEDED TO SUPPORT NON LOAD BEARING INTERIOR WALLS WITH 2xG FLOOR JOIST @ I G" O.C. 2) COORDINATE PRE -FAB FLOOR TKU55 DEPTH AND Al`FACHMENT PER MANUFACTURER'S AND CODE REQUIREMENTS. 3) CONTRACTOR TO CONTACT ARCHITECT, STRUCTURAL_ ENGINEER AND OWNER ANY D15CREPANCIE5 IN DRAWI NG5 BETWEEN TRADES. 4) CONTRACTOR TO CONTACT ARCHITECT, STRUCTURAL ENGINEER AND OWNER IF ANY EXISTING, ABNORMAL STRUCTURAL CONDITIONS ARE DISCOVERED UPON REMOVAL OF EXISTING STRUCTURE. 36" HIGH (CONTINUOUS RAILING A313 OPP051TE 2X BLOCKING @ 24" O.C. NEW P.T. 4X4 POST — BEYOND (PAINT) 5 EXTERIOR STAIR SECTION iQ4} SCALE: 314"= P -O" m d- 1` Lu SCALE: 114"= 1'-0" r_n;=, 1 -,Ml i r<r1J l_'d --t vv/ 2X6 COLLAR TIES 2x6 WOOD JOIST ATTACHED W1 51MF50N LUC2GZ JOIST HANGER SOLID HATCH INDICATES LOAD BEARING WALL (TYPICAL) lim SECOND FLOOR FRAMING SCALE: 114"= P -O' 1 0'-1 0" (13 EQ. TREAD5 @ 10" AND 14 RISERS @ 7.4311) 5'-0" LANDING I�nnrrrnn rnr lc_- �f-il NI/^N L/\ I LR1%.JR J 1 hlR r LH1V V3041 5CALE: 3/4'= P-0" tCIO— � m N N z �c 0/ z o �p O o < W u' Z Q Q 0 Lu EDU < f— z �g w a d z uw 0 4 Q d ED ED O 7- fl RCPS, FRAMING PLANS, AND 5TA1 R PLAN 1 .I z O () w W D Lu Q W � z (s) Lu O (s) ts) w Lu Q CZ IL CL T) W cv �o Q — N o RCPS, FRAMING PLANS, AND 5TA1 R PLAN 1 .I STANDING SEAM METAL ROOF W1-� WATERPROOF MEMBRANE ON 5/8" T*G DECKING OVER 2XG RAFTR5 (R-30 BATT INSULATION) FIN MOUNTED 50LID VINYL WINDOW WINDOW 51LL EL. _ ! 0'-G" A.F.F. SECOND FLOOR EL. _ 8'-8" A.F.F. 112" PLYWOOD DECKING ON 2X8— FLOOR TKU55E5 @ 12" O.C. 2x4 WOOD 5TUD — WALL @ I G" O.C. W1 WOOD SHAKE 51DING ON 112" PLYWOOD SHEATHING WITH WATER RE515TIVE BARP.JER WITH CONT. K-1 3 BATT IN5ULATION WINDOW SILL EL. U 2_'-10" A.F.F. 4" CONCRETE BREAK AWAY SLAB FIN15H FLOOR EL. = 0'-0" I WALL SECTION 1 101 5CALE: 112"= 1'-0" STANDING SEAM M TAL ROOF W/ —� WATERPROOF MEM 3RANE ON 5/8" Tt-G DECKING OVER 2XG RAFTERS (R-30 BATT INSULATION) 12 4 TRU55 BEARING EL. 17-b" A.F.F. 2x4 WOOD 5TUD WALL @ I G" O.C. W1 WOOD 5HAKE 51DING ON 112" PLYWOOD 5HEATHING WITH WATER KE515TIVE BARRIER WITH CONT. R-13 BATT IN5ULATION FIN MOUNTED 50LID VINYL SLIDING DOOR 30" HIGH WOOD GUARD RAIL --- i 1 4 A3C74 5ECOND FLOOR EL. CM 61-8" A.F.F. 112" PLYWOOD DECK'NG ON 2X8 FLOOR TKU55E5 @ 12" O.C. 50LID CORE FIBERG DOUBLE GARAGE DC WINDOW 51 LL EL. _ 2'-10" A.F.F. 4" CONCRETE B BEAK AWAY SLAB FIN15H FLOOR EL. = 0-0" P.T. CONTINUOU5 2X 12 5KIP\T BOARD (BEYOND) P.T. I X8 5TAIR R15ER (PAINT) P.T. 2X 12 STAIR TREAD— + P.T. I X8 5T R15ER (P T) 5T STRINGER CUT OM P.T. 2X 12 WALL SECTION 5 1 Q 5CALE: 112"= I'-0" 1/4" 1 STAIR DETAIL 1 3 r'CALE: 3"= 1'-0" e STANDING SEAM METAL ROOF W1 WATERPROOF MEMBRANE ON 518" T*G DECKING OVER 2XG RAFTER5 (R-30 BATT IN5ULATION) /1 TRU55 BEARING EL. _ 17-8" A. F. F. 2x4 WOOD 5TUD WALL @ I G" O.C. W1 WOOD 5HAKE 51DING ON 112" PLYWOOD 5HEATHING WITH WATER RE515TIVE BARRIER WITH CONT. K-13 BATT INSULATION 5ECOND FLOOR EL. _ A.F.F. 112" PLYWOOD DECKING ON 2X8 FLOOR TKU55E5 @ 12" O.C. 3 WINDOW 51 LL EL. _ A304 2'- 10" A.F.F. 4" CONCRETE BREAK AWAY 5LAB I 1 FIN15H FLOOR EL. = 0'-0" 3 -WALL SECTION 3 A3 101 SCALE: 112"= i'-0" RAILING CAP CUT A 2X4.1 (BEYOND) @ 24" O.C. P.T. CONTINUOUS 2X 12 5KI RT BOARD EXTERIOR STAIR SECTION DETAIL SCALE: I -112"= P -O" WOOD SHAKE 51DING ON 112" PLYWOOD 5HEATHING WITH WATER RE515TI VE BARRIER 5TARTER STRIP CONT. "Z" FLA5H I NG I X4 BOARD TRIM (PAI NT) CONT. BACKER ROD AND 5EALANT DOOR JAMB (PER DOOR - M AN U FACTU REK5 KEQUI REMENT5) 50LID CORE 1`I13ERGLA55 ENTRY DOOR 2X4 5TUD WALL (I G" O.C.) W1 CONT. BATT IN5ULATION 112" GWB (PAINT) (2) P.T. 2XG HEADER W1 s ALTERNATING 112" PLYWOOD 5PACER5 5 EXT. DOOR HEAD DETAIL ,A3 13 5CALE: I- 112"= 1'-0" WOOD 5HAKE 51DING ON 112" PLYWOOD 5HEATHING WITH WATER RE515TIVE BARRIER STARTER 5TRIP CONT. "Z" FLA5HING I X4 BOARD TRIM (PAINT) CONT. BACKER ROD AND 5EALANT FIN MOUNTED 50LID VINYL WINDOW W/ (5HIM A5 NECE55ARY) 112" GWB (PAINT) 2X4 5TUD WALL (I G" O.C.) W1 CONT. BATT IN5ULATION I X4 WOOD TRIM (PA! NT) 1 XG WOOD TRIM (PAINT) (2) P.T. 2XG HEADER W1 ALTERNATING 112" PLYWOOD 5PACER5 WINDOW HEAD DETAIL 3 ! 3 5C77 I- 112"= 1'-0" FIN MOUNTED 50LID VINYL WINDOW (SHIM A5 NECE55AKY) CONT. BACKER, ROD AND 5EALANT CONTINUOU5 FLA5HING- I X3 ON I X4 BOARD TRIM LEAVE APPROPRIATE GAP AND CAULK WOOD 5HAKE 51DING— ON 112" PLYWOOD 5HEATHING WITH WATER KE515TIVE BARRIER I XG WOOD TRIM (PAINT) �— I X4 WOOD TRIM (PAINT) (2) P.T. 2XG 51LL PLATE 112" GWB (PAINT) 2X4 5TUD WALL (I G" O.C.) WI CONT. BATT INSULATION WINDOW SILL DETAIL 3 131 5CALE: I-) 12"= 1'-O° RIPPED 2x3 HANDRAIL (4 7/8" PERIMETER) I x2 TRIM W/ 1/4" REVEF` 8 HANDRAIL DETAILS 131 SCALE: 3"= P-0" �— z FROM P.T. 2X3 (PAINT) m ON CONTINUOU5 P.T. N / n/ I X2 TRIM BOARD < u- (PAINT - BOTH 51 DE5) o Z0 3'-011 0 P.T. 2X2 WOOD PICKET 4" O.C. (PAINT) U w O P.T. 2X2 BOTTOM m RAIL (PAINT) z P.T. 2X 12 5TA1 R TREAD d Q Q w z w o 5TAIR 5TRINGER CUT Q_; z FROM P.T. 2X 12 <t m 0 p u.i 2X4.1 (BEYOND) @ 24" O.C. P.T. CONTINUOUS 2X 12 5KI RT BOARD EXTERIOR STAIR SECTION DETAIL SCALE: I -112"= P -O" WOOD SHAKE 51DING ON 112" PLYWOOD 5HEATHING WITH WATER RE515TI VE BARRIER 5TARTER STRIP CONT. "Z" FLA5H I NG I X4 BOARD TRIM (PAI NT) CONT. BACKER ROD AND 5EALANT DOOR JAMB (PER DOOR - M AN U FACTU REK5 KEQUI REMENT5) 50LID CORE 1`I13ERGLA55 ENTRY DOOR 2X4 5TUD WALL (I G" O.C.) W1 CONT. BATT IN5ULATION 112" GWB (PAINT) (2) P.T. 2XG HEADER W1 s ALTERNATING 112" PLYWOOD 5PACER5 5 EXT. DOOR HEAD DETAIL ,A3 13 5CALE: I- 112"= 1'-0" WOOD 5HAKE 51DING ON 112" PLYWOOD 5HEATHING WITH WATER RE515TIVE BARRIER STARTER 5TRIP CONT. "Z" FLA5HING I X4 BOARD TRIM (PAINT) CONT. BACKER ROD AND 5EALANT FIN MOUNTED 50LID VINYL WINDOW W/ (5HIM A5 NECE55ARY) 112" GWB (PAINT) 2X4 5TUD WALL (I G" O.C.) W1 CONT. BATT IN5ULATION I X4 WOOD TRIM (PA! NT) 1 XG WOOD TRIM (PAINT) (2) P.T. 2XG HEADER W1 ALTERNATING 112" PLYWOOD 5PACER5 WINDOW HEAD DETAIL 3 ! 3 5C77 I- 112"= 1'-0" FIN MOUNTED 50LID VINYL WINDOW (SHIM A5 NECE55AKY) CONT. BACKER, ROD AND 5EALANT CONTINUOU5 FLA5HING- I X3 ON I X4 BOARD TRIM LEAVE APPROPRIATE GAP AND CAULK WOOD 5HAKE 51DING— ON 112" PLYWOOD 5HEATHING WITH WATER KE515TIVE BARRIER I XG WOOD TRIM (PAINT) �— I X4 WOOD TRIM (PAINT) (2) P.T. 2XG 51LL PLATE 112" GWB (PAINT) 2X4 5TUD WALL (I G" O.C.) WI CONT. BATT INSULATION WINDOW SILL DETAIL 3 131 5CALE: I-) 12"= 1'-O° RIPPED 2x3 HANDRAIL (4 7/8" PERIMETER) I x2 TRIM W/ 1/4" REVEF` 8 HANDRAIL DETAILS 131 SCALE: 3"= P-0" �— z m ON N / n/ < u- z o Z0 0 U w O Q m z Lu d Q Q w z w o <[ Q_; z <t m 0 p u.i WALL 5ECTION5 D ETAI L5 A305 ZZ z 0 > w u.i w Q n Lu � � z O } D CJ (Si w zCLI� Q W c>_ a_ tai � Q — N WALL 5ECTION5 D ETAI L5 A305 3'-0" 2'-8" 2'-8" 2'-01 2'-4" 5'-0" lool WINDOW SCHEDULE DOOM SCHEDULE ID DOOR COUNT NOTES W H W H 3'-0" 5'-0" 8 1 3'-0" G'-8" 2 5OLID CORE FIBERGLA55 DOOR W1 FULL GLA55 LITE 2 2'-8" G'-8" I 50LID CORE FIBERGLA55 DOOR W1 FULL GLA55 LITE 3 2'-8" G-8" 1 HOLLOW CORE WOOD DOOR 4 2'-0" G'-8" I HOLLOW CORE WOOD DOOR 5 2'-4" G'-8" 2 HOLLOW CORE 5LIDING WOOD DOOR G 5'-0" G'-8" I HOLLOW CORE WOOD DOUBLE Bl -FOLD DOOR 7 5'-0" G'-8" 1 50LID CORE FIBERGLA55 DOUBLE DOOR W1 FULL GLA55 LITE5 8 9'-0" 7'-G" I 50LID CORE FIBERGLA55 DOUBLE GARAGE DOOR 3'-0" 2'-8" 2'-8" 2'-01 2'-4" 5'-0" lool WINDOW SCHEDULE ID DOOR COUNT NOTES ry W H 4 D A 3'-0" 5'-0" 8 DOUBLE HUNG FIN MOUNTED 50LID VINYL WINDOW B 3'-0" 4'-0" 1 2 DOUBLE HUNG FIN MOUNTED 50LID VINYL WINDOW C 2'-O" 3'-2" 1 1 5INGLE HUNG FlN MOUNTED 50LID VINYL WINDOW 3'-0" 2'-8" 2'-8" 2'-01 2'-4" 5'-0" lool DOOR TYPES 5GALE: 112"= P-0" t u Q 00, S WINDOW TYPES SCALE: 112"= P-0" loo F1 _ 2'-0" i cV cr7 � � m m aN ry 4 D a � UJ 0 _ aw DOOR TYPES 5GALE: 112"= P-0" t u Q 00, S WINDOW TYPES SCALE: 112"= P-0" loo F1 _ 2'-0" i cV cr7 � � m m aN ry 4 D a � UJ 0 _ aw z z j z -' a tu� Q Lu CD a p DOORS AND WI N DOW5 A306 Z 0 Lu to (n u� d D Lu Z t j} w 0 (n cf) 0 Ln U> D Q cn FE w a-- cv psi � — N D <9 d - DOORS AND WI N DOW5 A306 DESIGN CODE: --------------- 2017 FLORIDA BUILDING CODE - RESIDENTIAL DESIGN LOADS: -------------- ACTUAL AND UNIFORM ROOF LOADING: (cd=1.25) TOP CHORD LIVE LOAD - - - - - - - - - - - - - - - - - - - - - - 20 psf TOP CHORD DEAD LOAD _--------------------_ 15 psf (FLAT ROOF) BOTTOM CHORD LIVE LOAD --_.._----------------- 0 psf BOTTOM CHORD DEAD LOAD - - - - - - - - - - - - - - - - - - - 5 psf FLOOR LOADING: (cd=1.00) TOP CHORD LIVE LOAD (INTERIOR) --------------- 40 psf TOP CHORD LIVE LOAD (BALCONIES) -------------- 60 psf TOP CHORD LIVE LOAD (CORRIDOR)--------------- 100 psf TOP CHORD DEAD LOAD ,-------------------- 20 psf BOTTOM CHORD LIVE LOAD-------------------- 0 psf BOTTOM CHORD DEAD LOAD - - - - - - - - - - - - - - - - - - - 5 psf DEFLECTION CRITERIA: ROOF FRAMING: LIVE LOAD L/360 TOTAL LOAD L/240 FLOOR FRAMING: LIVE LOAD L/480 & TOTAL LOAD L/360 & 0.75" MAX WIND LOADING: (ASCE 7/10) TRIBUTARY AREA (sf) BASIC WIND SPEED - - - - - - - - - - - - - - - - - - - - - - - - - 130 MPH IMPORTANCE FACTOR _---------------------- 1.00 MEAN ROOF HEIGHT _----------------------- 20 FT ROOF PITCH ----------------------------- 8/12 BUILDING CATEGORY ------------------------ II EXPOSURE CATEGORY _----------------------_ D ENCLOSURE CLASSIFICATION -------------------_ ENCLOSED INTERNAL PRESSURE COEFFICIENT ---`.-----------_ t .18 COMPONENTS & CLADDING ALLOWABLE PRESSURES TRIBUTARY AREA (sf) INTERIOR ZONE (PSF) EDGE STRIP (PSF): a 3'- 0 10 +30.2 -32.9 +30.2 -40.5 50 +27.1 -29.6 +27.1 -34.2 100 +25.7 -28.2 +25.7 -31.2 • COMPONENT & CLADDING WALL ELEMENTS SHALL BE DESIGNED FOR BOTH POSITIVE AND NEGATIVE PRESSURES SHOWN IN TABLE ABOVE. • LINEAR INTERPOLATION IS PERMISSIBLE. • PLUS = PRESSURE AND MINUS = SUCTION. THE DISTANCE 'a' FROM OUTSIDE CORNERS OF BUILDING SHALL BE DESIGNED FOR EDGE STRIP PRESSURES. • DESIGN OF WINDOWS/DOORS FASTENING TO THE WALL FRAMING IS THE RESPONSIBILITY OF THE WINDOW/DOOR MANUF./SUPPLIER & SHALL MEET THE ABOVE NOTED POSITIVE AND NEGATIVE PRESSURES. GENERAL NOTES: THESE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DQ NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKERS AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT ARE NOT LIMITED TO, MEANS AND METHODS, BRACING, SHORING, FORMS, SCAFFOLDING, GUYING OR OTHER MEANS TO AVOID EXCESSIVE STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER OR STRUCTURAL OBSERVERS SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. TYPICAL DETAILS AND NOTES ON THESE SHEETS SHALL APPLY UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. CONSTRUCTION DETAILS NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR SIMILAR CONDITIONS. ALL WORK, MATERIALS AND CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES, REGULATIONS AND SAFETY REQMT'S. FOR CLARITY, ALL OPENINGS MAY NOT BE SHOWN ON DRAWINGS. SEE ALSO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING PLANS. ALL OPENINGS AND PENETRATIONS SHALL BE LOCATED AND VERIFIED BY ALL TRADES FROM DRAWINGS MADE BY THEM. CONTRACTOR SHALL NOT PROCEED WITH ANY WORK SHOWN ON DRAWINGS IF IN CONFLICT UNTIL RECEIVING CLARIFICATION FROM ARCHITECT. FOR FRAMING AT OPENINGS, SEE TYPICAL STRUCTURAL DETAILS. WHERE A DETAIL, TYPICAL DETAIL, SECTION, TYPICAL SECTION OR PLAN NOTE IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL SIMILAR OR LIKE CONDITIONS UNLESS OTHERWISE NOTED. CONTRACT DOCUMENTS INCLUDE, BUT ARE NOT LIMITED TO, THE STRUCTURAL DOCUMENTS (DRAWINGS AND SPECIFICATIONS), BUT DO NOT INCLUDE SHOP DRAWINGS, VENDOR DRAWINGS, OR MATERIAL PREPARED AND SUBMITTED BY THE CONTRACTOR. CONTRACT DOCUMENTS SHALL GOVERN IN THE EVENT OF A CONFLICT WITH THE CODE OF PRACTICE OR SPECIFICATIONS OF ACI, PCI, AISC, SJI OR OTHER STANDARDS. WHERE A CONFLICT OCCURS WITHIN THE CONTRACT DOCUMENTS, THE STRICTEST REQUIREMENT SHALL GOVERN. MATERIAL, WORKMANSHIP, AND DESIGN SHALL CONFORM TO THE REFERENCED BUILDING CODE. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. FOR DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS, SEE ARCHITECTURAL DRAWINGS. DO NOT SCALE FOR DIMENSIONS NOT SHOWN ON DRAWINGS. SEND WRITTEN REQUEST FOR INFORMATION TO THE ARCHITECT FOR DIMENSIONS NOT PROVIDED. ALL DIMENSIONS AND ELEVATIONS SHOWN ON STRUCTURAL DRAWINGS SHALL BE VERIFIED WITH ARCHITECTURAL DRAWINGS. RESOLVE ALL DISCREPANCIES WITH ARCHITECT PRIOR TO START OF CONSTRUCTION. DO NOT SCALE DRAWINGS COORDINATE THE STRUCTURAL DOCUMENTS WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL DOCUMENTS. ARCHITECT/STRUCTURAL ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCY OR OMISSION. CONTRACTOR HAS SOLE RESPONSIBILITY FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES OF CONSTRUCTION. CONTRACTOR HAS SOLE RESPONSIBILITY FOR THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS. CONTRACTOR HAS SOLE RESPONSIBILITY TO COMPLY WITH ALL OSHA SAFETY REGULATIONS FOR ITS EMPLOYEES. NO STRUCTURAL CHANGE FROM THE APPROVED PLANS AND SPECIFICATIONS SHALL BE MADE IN THE FIELD UNLESS WRITTEN APPROVAL IS OBTAINED PRIOR TO MAKING SUCH CHANGE. CHANGES WITHOUT THE WRITTEN APPROVAL SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONDITION SHALL BE REPAIRED OR REPLACED AS DIRECTED. THE MECHANICAL CONTRACTOR SHALL COORDINATE INSTALLATION OF THE REQUIRED INSERTS WITH THE GENERAL CONTRACTOR. REFER TO MECHANICAL DRAWINGS FOR SUPPORT STRUCTURES AND INSERTS. THE MECHANICAL CONTRACTOR SHALL FURNISH ALL NECESSARY STRUCTURES FOR MECHANICAL EQUIPMENT, HANGING DEVICES AND INSERTS FOR INSTALLATION OF MECHANICAL EQUIPMENT. FOR ELEVATORS ASSOCIATED WITH THIS PROJECT, EDGE OF SLAB OPENINGS AT PIT, FOUNDATION, FLOOR FRAMING AND ROOF FRAMING HAVE BEEN COORDINATED FOR DIMENSIONS, SLAB EDGE SUPPORTS, HOIST BEAM SUPPORTS AND RAIL SUPPORTS BASED ON ELEVATOR CUT SHEETS PROVIDED DURING THE DESIGN PHASE FOR THIS PROJECT. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE ELEVATOR MANUFACTURER FOR THE ELEVATOR(S) TO BE INSTALLED ON THE PROJECT AND SHALL ADJUST SLAB OPENING DIMENSIONS, PROVIDE MISCELLANEOUS FRAMING AS REQUIRED FOR SLAB OPENING ADJUSTMENTS, SLAB EDGE SUPPORTS, RAIL SUPPORTS AND HOIST BEAM SUPPORTS, AS REQUIRED. CONTRACTOR SHALL COORDINATE WITH ARCHITECT FOR ALL REQUIRED ADJUSTMENTS AS NOTED AND SHALL BE RESPONSIBLE FOR COSTS ASSOCIATED WITH ANY REQUIRED ADJUSTMENTS NOTED ABOVE FOR INSTALLATION OF ELEVATOR(S) AT NO ADDITIONAL COST TO OWNER. MA ItNIAL Z:etLA1-IL;A I UNJ: ANCHOR BOLTS &TREADED ROD: SHALL BE IN ACCORDANCE WITH ASTM A 307 OR ASTM F1554 GRADE 36. QT WIRE ROPE: GALVANIZED "AIRCRAFT" DESIGNED 7x19, 270KS1 WIRE ROPE. WASHERS: SHALL BE IN ACCORDANCE WITH ASTM A500 (GRADE B). NUTS: SHALL BE IN ACCORDANCE WITH ASTM A 563 GRADE A HEX. METAL CONNECTORS: ALL METAL CONNECTORS WHICH ARE EXPOSED TO EXTERIOR SHALL BE GALVANIZED. RETROFIT REBAR/ROD INSTALLATION: EMBEDMENT OF RODS OR REBAR DOWELS SHALL BE 12 BAR DIAMETER MINIMUM, HOLES SHALL BE '/4' LARGER THAN REBAR SIX AND '/8" LARGER THAN THREADED ROD SIZE. (U.O.N.) EPDXY: RED HEAD E'CON G5. REINFORCING STEEL: SHALL BE ASTM A615, GRADE 60. STRUCTURAL STEEL: SHALL BE ASTM A992, GRADE 50. WELDED WIRE FABRIC (WWF): SHALL BE ASTM A185. FOUNDATIONS: A SOILS REPORT WAS NOT PROVIDED TO LOU PONTIGO & ASSOCIATES (LPA). LPA HAS DESIGNED A PILE SUPPORTED FOUNDATION WITH 14" 1DIAMETER AUGER CAST PILES WITH A GROUT STRENGTH OF 5000 PSI. LPA HAS ASSUMED THE AUGER CAST PILES TO HAVE A CAPACITY OF 40 TONS IN COMPRESSION, 18 TONS IN TENSION AND 5 KIPS IN SHEAR. THE PILE DEPTH HAS BEEN ASSUMED TO BE -16.50' NAVD. IT IS THE RESPONSIBLITY OF THE CONTRACTOR/OWNER TO HIRE A GEOTECHNICAL ENGINEER TO VERIFY PILE CAPACITY AND PILE DEPTH. THE- FOUNDATION MAY BE MODIFIED AFTER A GEOTECHNICAL INVESTIGATION IS PERFORMED. ALL AUGER PILE REINFORCEMENT SHALL HAVE A MINIMUM CONCRETE COVER OF 2" TO THE #3 TIES. AUGER PILE PLACEMENT TOLERANCE: PLUS OR MINUS 2 INCHES. THE CONTRACTOR SHALL ENGAGE THE SERVICE OF A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR AN APPROVED TESTING AGENCY TO SUPERVISE AND CERTIFY THAT THE PILE INSTALLATION COMPLIES WITH THE DESIGN REQUIREMENTS. RECORDS OF THE REINFORCING FOR EACH PILE; EACH INDIVIDUAL PILE DEPTH AND QUANTITY OF CONCRETE GROUT VOLUME INSTALLED FDR EACH PILE; TOTAL NUMBER OF INSTALLED PILES; TOTAL LENGTH OF INSTALLED PILES; TOTAL CALCULATED CONCRETE GROUT VOLUME FOR ALL OF THE PILES; ACTUAL TOTAL CONCRETE GROUT VOLUME INSTALLED FOR ALL OF THE PILES; ,ND DEVIATION OF EACH PILE FROM THE SPECIFIED LOCATION SHALL BE KEPT AND SUBMITTED TO THE ENGINEER OF RECORD UPON COMPLETION OF THE AUGER PILE WORK. FOUNDATION PLAN ONLY CONVEYS STRUCTURAL INFORMATION. FOR GENERAL FEATURES, CONDUITS, ELECTRICAL EMBEDS, STEP HEIGHTS, ETC., SEE ARCHITECTURAL PLANS. DO NOT SCALE FOOTING DIMENSIONS AND LOCATIONS FROM THE FOUNDATION PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINED ON PLAN THEN CONTACT THE STRUCTURAL ENGINEER.. UNLESS OTHERWISE NOTED ON DRAWINGS, MINIMUM CONCRETE COVER FOR REINFORCING SHALL BE 3" IN FOOTINGS AND MESH SHALL BE CENTERED IN SLAB ON GRADE USING SUPPORT BARS AND CHAIRS. IN ALL CONTINUOUS FOOTINGS PROVIDE #4 Q 48" O.C. OR ROD CHAIRS. PROVIDE CONTINUITY OF REINFORCING AT INTERSECTIONS OF PERPENDICULAR CONCRETE ELEMENTS BY INSTALLING CORNER BARS, MINIMUM OF 40 BAR DIAMETERS INTO EACH ELEMENT. SPLICES IN REINFORCING, WHERE PERMITTED, SHALL BE 48 BAR DIAMETERS THE GEOTECHNICAL ENGINEER SHALL ACT AS THE OWNER'S REPRESENTATIVE AND SHALL MAKE OBSERVATIONS AND TESTS AS CONSIDERED NECESSARY FOR QUALITY CONTROL. WHERE FOUNDATIONS OR OTHER CRITICAL ELEMENTS ARE TO BE SUPPORTED ON ENGINEERED FILL, CONTINUOUS OBSERVATIONS AND TESTS OF GRADING OPERATIONS SHALL BE MADE BY THE GEOTECHNICAL ENGINEER. ALL TESTS SHALL BE PERFORMED IN ACCORDANCE WITH PROCEDURES SET FORTH IN THE CURRENT BOOK OF STANDARDS OF THE AMERICAN SOCIETY OF TESTING AND MATERIALS (ASTM). WHERE FILL IS REQUIRED, IT SHALL BE PLACED IN ACCORDANCE WITH INSTRUCTIONS OF THE PROJECT GEOTECHNICAL ENGINEER TO MAINTAIN DESIGN BEARING PRESSURE. UNLESS SPECIFICALLY NOTED AS "CANTILEVERED" ON PLAN OR DETAILS, WALLS RETAINING EARTH MUST BE SHORED CONTINUALLY PRIOR TO COMPLETION OF STRUCTURAL SLABS ON GRADES AND/OR ELEVATED SLABS HAVE BEEN PLACED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE DESIGN, ADEQUACY, SAFETY, AND STABILITY OF TEMPORARY ERECTION BRACING AND SHORING. BACKFILL AGAINST WALLS SHALL BE DEPOSITED EVENLY IN 8" TO 12" LIFTS AGAINST BOTH SIDES OF WALL UNTIL THE LOWER FINAL GRADE IS REACHED. CONTRACTOR SHALL PROVIDE ADEQUATE BRACING OR SHORING FOR ALL WORK DURING THE CONSTRUCTION PERIOD. BACKFILL SHALL NOT BE PLACED AGAINST WALLS UNTIL THE WALLS HAVE ACHIEVED 75% OF SPECIFIED DESIGN STRENGTH. FOOTINGS SHALL BE (CENTERED ABOUT COLUMN LINES UNLESS NOTED OTHERWISE. TOP OF FOOTING ELEVATIONS PROVIDED ON DRAWINGS ARE FOR PURPOSES OF CONTRACT & SHALL BE ADJUSTED, AS REQUIRED, AT TIME OF EXCAVATION TO BEAR ON PROPERLY PREPARED SUPPORT SUBGRADE (PER GEOTECHNICAL REPORT RECOMMENDATIONS OR FIELD DIRECTIVES OF GEOTECHNICAL ENGINEER ON SITE) OR TO ADJUST FOOTING ELEVATIONS TO AVOID INFLUENCE BETWEEN FOUNDATIONS & BURIED PLUMBING. SEE TYPICAL FOOTING -TRENCH INFLUENCE DETAIL FOR SIMILAR REQUIREMENTS FOR INFLUENCE BETWEEN FOUNDATIONS & BURIED PLUMBING. DO NOT EMBED PIPING WITHIN OR PASS PIPING VERTICALLY OR HORIZONTALLY THROUGH ISOLATED FOOTINGS. WHERE THE GEOTECH ICAL ENGINEER FINDS AN UNSTABLE CONDITION IS BEING CREATED, EITHER BY CUTTING OR FILLING, THE WORK SHALL NOT PROCEED IN THAT AREA UNTIL AN INVESTIGATION HAS BEEN MADE AND THE GRADING PLAN REVISED. FILL TO BE COMPACT D TO 95% OF MAXIMUM DENSITY AS DETERMINED BY ASTM D-1557. PLACE FILL IN LAYERS OF 8" THICK MAXIMUM & U ODER THE DIRECT SUPERVISION OF THE GEOTECHNICAL ENGINEER. FILL TO BE TESTED TO VERIFY COMPACTION AS REWIRED BY THE GEOTECHNICAL ENGINEER. TESTS FOR DEGREE OF COMPACTION SHALL BE DETERMINED BY THE ASTM D-1556 OR ASTM D-2922 TEST METHODS. OBSERVATION AND FIELD TESTS SHALL BE CARRIED ON DURING FILL AND BACKFILL PLACEMENT BY THE GEOTECHNICAL ENGINEER TO ASSIST THE CONTRACTOR IN OBTAINING THE REQUIRED DEGREE OF COMPACTION. IF LESS THAN 95 (U.O.N. IN SOILS REPORT) PERCENT IS INDICATED, ADDITIONAL COMPACTION EFFORT SHALL BE MADE WITH ADJUSTMENT OF THE MOISTURE CONTENT AS REQUIRED COMPACTION IS OBTAINED. UAS I -IN-FL L L; N(;K I TO BE MIXED AND P .ACED IN ACCORDANCE WITH ACI 301, ACI 506 & 506.2. ALL REINFORCED CONCRETE TO HAVE 28 DAY COMPRESSIVE S _RENGTHS AS FOLLOWS: ALL STRUCTURAL ELEMENTS f'c = 4000 PSI UNLESS NOTED OTHERWISE. COLUMNS & WALLS: f'c = 4,000 PSI BEAMS & SLA 's: f'c = 4,000 PSI AUGERCAST PILES: f'c = 5,000 PSI BREAK -AWAY $LAB -ON -GRADE: f'c = 3,000 PSI ALL CONCRETE MIX DESIGN SUBMITTALS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE EACH PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE. UNLESS NOTED OTHERWISE, NORMAL WEIGHT CONCRETE (145 PCF) SHALL BE USED WITH 3/4" MAX. (ELEVATED) OR 1" MAX. (SLAB -ON -GRADE) COARSE AGGREGATE CONFORMING TO ASTM C 33. PROTECT FRESHLY POURED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD AND HOT TEMPERATURES. START CURING AS SOON AS FREE WATER HAS DISAPPEARED FROM THE CONCRETE SURFACE AFTER PLACING AND FINISHING. ALL CURING PROCEDURES TO FOLLOW ACI 308. PROTECT CONCRETE FROM DAMAGE AND REDUCED STRENGTH CAUSED BY FROST, FREEZING ACTIONS AND LOW TEMPERATURES IN COMPLIANCE WITH ACI 306. PROTECT CONCRETE FROM DAMAGE AND REDUCED STRENGTH CAUSED BY HIGH TEMPERATURES IN COMPLIANCE WITH ACI 305. UNIFORMLY C00 WATER AND AGGREGATES BEFORE MIXING TO OBTAIN A CONCRETE MIXTURE TEMPERATURE OF NOT GREATER THAN 90 D -GREES FAHRENHEIT AT POINT OF PLACEMENT. CAST -IN-PLACE CONCRETE (CONTINUED): WHERE NEW CONCRETE IS TO BE POURED ONTO EXISTING CONCRETE, ROUGHEN AND CLEAN SURFACE OF THE ADJOINING AREA AND COAT WITH SIKADUR 32 HI -MOD OR AN APPROVED BONDING AGENT. NO ADDITIONAL WATER SHALL BE ADDED TO THE CONCRETE AT THE JOB SITE. SEE ARCHITECTURAL, ELECTRICAL, MECHANICAL, FIRE PROTECTION AND PLUMBING DRAWINGS FOR DRIPS, CHAMFERS, REGLETS, SLOTS, SLEEVES, RUSTICATIONS, INSERTS ANCHORS AND OTHER EMBEDDED ITEMS NOT NOTED ON STRUCTURAL DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING & PLACING ALL EMBEDDED ITEMS SHOWN ON DRAWINGS & ADDITIONAL ITEMS NOTED IN THIS NOTE, AS REQUIRED BY OTHER TRADES. ALL OPENINGS REQUIRED BY OTHER TRADES ARE TO BE COORDINATED W/ARCH. & MECH. DWGS., AND ARE SUBJECT TO STRUCTURAL ENGINEERING APPROVAL. ALL OPENINGS IN CONCRETE SLABS SHALL BE LOCATED, SIZED AND REINFORCED (WITH THE EXCEPTION OF SMALL OPENINGS AND/OR SLEEVES OF A SIZE THAT WILL NOT DISPLACE OR INTERRUPT THE CONTINUITY OF THE REINFORCING) AS SHOWN ON RESPECTIVE FLOOR PLANS AND DETAILS. ALL OPENINGS IN SLAB LESS THAN 10" SHALL BE COORDINATED WITH ARCHITECTURAL & MEP DRAWINGS AND ARE SUBJECT TO STRUCTURAL ENGINEER'S APPROVAL. ANY ALTERATIONS REQUIRE APPROVAL OF THE STRUCTURAL ENGINEER. (SEE TYPICAL SLAB OPENING DETAIL). DEFECTIVE AREA IN CONCRETE INCLUDING, BUT NOT LIMITED TO, HONEY -COMBING, SPALLS, AND CRACKS WITH WIDTHS EXCEEDING 0.01 INCH SHALL BE REPAIRED. EXTENT OF DEFECTIVE AREA TO BE DETERMINED BY THE STRUCTURAL ENGINEER. CONCRETE REINFORCING REINFORCING STEEL AND ACCESSORIES SHALL BE DETAILED IN ACCORDANCE WITH ACI 315-99 (MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES) AND CRSI MSP2-01 (MANUAL OF STANDARD PRACTICE) (IBC 2009: CRSI MANUAL OF STANDARD PRACTICE, 28TH EDITION) REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60 (UNLESS NOTED OTHERWISE). UNLESS NOTED OTHERWISE, CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS FOLLOWS: 1. CONCRETE CAST AGAINST EARTH ----------------- 3" 2. FORMED CONCRETE EXPOSED TO EARTH OR WEATHER ---- 2" 3. WALLS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3/4„ 4. COLUMNS/BEAMS (TO MAIN REINF.)---------------- 1 1/2" SPLICES IN REINFORCEMENT, WHERE PERMITTED SHALL BE AS FOLLOW: 1. WELDED WIRE MESH -------------------------- 8" 2. ALL OTHERS ------------------------------ CLASS "B» TENSION, CASE "1" MINIMUM U.Q.N. (SEE CHART) CLASS "B", CASE I TENSION SPLICES IN INCHES c f'c = 3000 psi f'c = 4000 psi f'c = 5000 psi BAR SIZE ALL THEA TOP BARS ALL OTHERS TOP BARS ALL OTHERS TOP BARS # 3 21 28 18 24 17 22 # 4 28 37 25 32 22 29 # 5 36 46 31 40 28 36 # 6 43 56 37 48 33 43 # 7 62 81 54 70 48 63 # 8 71 93 62 80 55 72 # 9 80 104 70 90 62 81 # 10 90 118 78 102 70 91 # 11 100 1 131 87 113 78 1 101 SUBMIT SHOP DRAWINGS WHICH ADEQUATELY DEPICT THE REINFORCING BAR SIZES AND PLACEMENT. WRITTEN DESCRIPTION OF REINFORCEMENT WITHOUT ADEQUATE SECTIONS, ELEVATIONS AND DETAILS IS NOT ACCEPTABLE. ALL WELDED REINFORCING STEEL SHALL CONFORM TO ASTM A-706, GRADE 60, AND BE USED ONLY WITH PRIOR PERMISSION FROM THE STRUCTURAL ENGINEER. ALL TENSION SPLICES, INCLUDING SPLICES FROM BARS LABELED CONTINUOUS, SHALL CONFORM TO ACI 318-11. SPLICES SHALL BE CLASS B IN ACCORDANCE WITH ACI 318, UNLESS NOTED OTHERWISE. REINFORCEMENT SHALL BE SPLICED ONLY AT LOCATIONS SHOWN OR NOTED IN THE STRUCTURAL DOCUMENTS, EXCEPT REINFORCEMENT MARKED "CONTINUOUS" CAN BE SPLICED AT LOCATIONS DETERMINED BY CONTRACTOR. SPLICES AT OTHER LOCATIONS SHALL BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. (FBC 2010: ACI 318-08) WELDED WIRE REINFORCEMENT SHALL CONFORM TO ASTM A-185 AND BE LAPPED TWO FULL PANELS, TIED ON EACH SIDE AND SHALL BE SUPPLIED IN FLAT SHEETS. LONGITUDINAL REINFORCING BARS IN FOOTINGS SHALL BE PLACED CONTINUOUS AT CORNERS AND INTERSECTIONS. FOR EVERY VERTICAL OR HORIZONTAL BAR DISCONTINUED BY AN OPENING, ONE BAR (MIN. OF 2 BARS) SHALL BE ADDED @ SIDE OF OPENING (HALF TO EACH SIDE - TYPICAL). PROVIDE CORNER BARS AT ALL CONTINUOUS REINFORCING BARS AT ALL MEMBERS (FOUNDATIONS, WALLS, SLABS, BEAMS & OTHER MEMBERS). PROVIDE DOWELS FROM FOUNDATIONS, THE SAME SIZE & NUMBER AS THE VERTICAL WALL OR COLUMN REINFORCING, UNLESS NOTED OTHERWISE. ALL DOWELS AND TERMINATING BARS SHALL HAVE A STANDARD 90 DEGREE HOOK. ALL HORIZONTAL REINFORCING SHALL BE CONTINUOUS THROUGH CONTROL AND/OR CONSTRUCTION JOINTS AND AROUND CORNERS. FORMWORK & SHORING: THE FORM AND SHORING SYSTEM SHALL BE DESIGNED BY A FLORIDA REGISTERED ENGINEER IN ACCORDANCE WITH ACI 301 & 347 "RECOMMENDED PRACTICE FOR CONCRETE FORMING". SHORING AND RE -SHORING PLANS MUST BE SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER AND SUBMITTED WITH CALCULATIONS. CALCULATIONS FOR THE RE -SHORING PROCESS MUST INCLUDE THE POURING AND THE STRIPPING CYCLE BASED ON THE CONSTRUCTION SCHEDULE. THE ASSUMED CONCRETE STRENGTH AT THE TIME OF STRIPPING ANY NEW SLAB AND MUST BE SUBSTANTIATED BY PROVIDING CONCRETE MIX DESIGN AND EXPECTED STRENGTH GAIN WITH AGE. THE CALCULATIONS MUST SHOW THAT THE SLABS SUPPORTING A NEW SLAB ARE NOT OVER -STRESSED BASED ON THE ASSUMED STRENGTH AND THE AGE AT THE TIME OF POURING. ALL RE -SHORING CALCULATIONS SHALL INCLUDE CALCULATIONS FOR MUD SILLS AND ANY CONSTRUCTION LOADING SUCH AS CONCRETE PLACING BOOM SUPPORT ETC. STRUCTURAL DRAWING INDEX c m N N N0N6 LIG. LL. U) o r� 0 0 r - w w w 0 (D � o 0 U- ENTIRE SET SUBMITTED r V O SO.O DESIGN CRITERIA & GENERAL NOTES 0 1 .1L ' pw w SO.1 GENERAL NOTES 0 z Lu uj SO.2 GENERAL NOTES • m 0 t4 i S1.OA PILE LAYOUT PLAN U O� wN � Q d2 S1.013 SLAB DIMENSION PLAN • U S1.0 FOUNDATION PLAN � F S1.01 FOUNDATION DETAILSF_ # z c m N N N0N6 LIG. LL. U) o z (D � o 0 U- 06N V O � .E � 1 .1L ' pw w ( z Lu uj Q z ��C) V m 0 t4 i H:P U O� wN � Q d2 U � F LQ z m N N N0N6 LIG. LL. Z 0 o z Ez � o U- V W uj z 1 .1L pw ( z Lu uj Q z ��C) V m 0 t4 i O DESIGN CRITERIA AND GENERAL NOTES 50.0 FORMWORK & SHORING: (CONTINUED) FINAL SIGNED AND SEALED SHORING AND RESHORING DRAWINGS SHALL BE ISSUED TO THE ENGINEER OF RECORD FOR THE PROJECT AND THE THRESHOLD BUILDING INSPECTOR FOR HIS USE TO INSURE COMPLIANCE WITH THESE DRAWINGS. NO FLAT SLAB SHALL BE STRIPPED AND RESHORED UNTIL CONCRETE HAS ACHIEVED A MINIMUM OF 85% OF DESIGN STRENGTH AND 72 HOURS OF AGE. BASED ON THE LOWEST CONCRETE TEST. CONCRETE MASONRY: ALL MASONRY DESIGN AND CONSTRUCTION SHALL CONFORM TO ACI 530-05/ASCE 5-05/TMS 402-05 AND ACI 530.1-05/ASCE 6-05/TMS 602-05. CMU SHALL BE IN ACCORDANCE WITH ASTM C90-75, HOLLOW LOAD-BEARING (CMU), TYPE 1, GRADE N-1, NORMAL WEIGHT, WITH A MINIMUM COMPRESSIVE STRENGTH OF 1900 PSI (f'm=1500 PSI). GROUT ALL CELLS CONTAINING VERTICAL REINFORCEMENT IN 5-0" MAXIMUM LIFTS PROVIDE CLEANOUTS PER ACI 530.1-02 IN THE BOTTOM OF COURSE OF MASONRY WHEN THE WALL HEIGHT EXCEEDS 5'-0". CONCRETE MASONRY UNITS SHALL BE NORMAL WEIGHT AND CONFORM TO ASTM C-90. LAY IN RUNNING BOND UNLESS NOTED OTHERWISE. F'M SHALL BE 1500 PSI (MIN. CMU COMPRESSIVE STRENGTH = 1900 PSI), COMPLETE TEST REPORTS THAT DOCUMENT MINIMUM COMPRESSIVE STRENGTH SHALL BE SUBMITTED TO THE BUILDING INSPECTOR. SEE ARCHITECTURAL DRAWINGS FOR EXACT LAYOUT AND CONFIGURATION. COMPLETE SHOP DRAWINGS (INCLUDING MEMBERS, COMPONENTS, CONNECTIONS AND ALL LOADS CLEARLY INDICATED ON THE CALCULATIONS & SHOP DRAWINGS. SHOP DRAWINGS SHALL SHOW & SPECIFY ALL CONNECTIONS UTILIZED WITHIN THE RAILING SYSTEM AS WELL AS CONNECTIONS TO AND LOADS IMPOSED UPON THE STRUCTURAL FRAMING SYSTEM) FOR CONSTRUCTION OF STAIRS, HANDRAILS, AND GUARDRAILS SHALL BE SEALED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH CONSTRUCTION WILL OCCUR AND SHALL BE AVAILABLE AT THE JOB SITE DURING TIMES OF INSPECTION. IT IS REQUIRED THAT THE SITE PREPARATION & FOUNDATION CONSTRUCTION BE MONITORED BY THE GEOTECHNICAL ENGINEER OR HIS REPRESENTATIVE. THE FOLLOWING ARE RECOMMENDED MINIMUM SAMPLING AND TESTING FREQUENCIES. AT LEAST ONE MOISTURE -DENSITY (PROCTOR) TEST, ATTERBERG LIMITS TEST AND PERCENT FINER THAN #200 SIEVE TEST SHOULD BE PERFORMED PER EACH SOIL TYPE SUCH AS SUBGRADE AND SELECT FILL. IN STRUCTURE AREAS, AT LEAST 1 DENSITY AND MOISTURE CONTENT TEST PER 5000 SQUARE FEET OF SURFACE AREA GROUT SHALL BE IN ACCORDANCE WITH ASTM C476 WITH A MINIMUM OF 28 DAY COMPRESSIVE STRENGTH OF 3000 psi SHOULD BE PERFORMED ON THE SUBGRADE SOILS, AND AT LEAST 1 DENSITY AND MOISTURE CONTENT TEST PER 5000 PER ASTM C1019. GROUT SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE OF els PLACED AT AN 8" TO 11" SLUMP. SQUARE FEET OF SURFACE AREA SHOULD BE PERFORMED FOR EACH COMPACTED 8 -INCH THICK LAYER OF FILL. TESTING MORTAR SHALL CONFORM TO ASTM C270 AND TYPE M OR S. TYPE N MORTAR MAY BE USED IN BRICK VENEER. BACKFILL TRENCHES SHOULD BE AT LEAST 1 DENSITY AND MOISTURE CONTENT TEST PER 100 LINEAR FEET OF TRENCH PER 8 -INCH COMPACTED FILL THICKNESS. THE SPACING/LOCATIONS FOR TYPICAL JOINT REINFORCING AT 25% OF ANY ISOLATED COLUMN FOOTING LOCATIONS JOINT REINFORCING - TRUSS TYPE, 9 GAUGE SPACED VERTICALLY AT 16" UNLESS NOTED OTHERWISE AND CONFORM TO ASTM A-82. VERTICAL REINFORCING IN CONCRETE MASONRY (AS REQUIRED) SHALL BE DOWELED INTO THE FOUNDATION AND EXTEND INTO THE BOND BEAM AT THE FLOOR OR ROOF. PROVIDE MIN. 4" X 4" OPENING AT U BLOCK FOR VERTICAL BAR. PROVIDE REINFORCING IN CONCRETE MASONRY GROUTED CELLS AT EACH SIDE OF OPENING, EQUAL TO THE REINFORCING DISPLACED. MINIMUM REINFORCING SHALL BE (1) TYPICAL REINFORCEMENT BAR AT EACH SIDE UNLESS REINFORCED CONCRETE JAMB IS CALLED OUT. A MINIMUM OF AT LEAST FIVE (5) DENSITY AND MOISTURE CONTENT TESTS SHOULD BE PERFORMED IN THE BUILDING AREA ON THE SUBGRADE SOILS, AND A MINIMUM OF AT LEAST FIVE (5) DENSITY AND MOISTURE CONTENT TESTS SHOULD BE PERFORMED PER 8 -INCH COMPACTED THICKNESS OF FILL IN THE BUILDING AREA. TESTING OF BACKFILLED TRENCHES SHOULD BET LEAST 1 DENSITY AND MOISTURE CONTENT TEST PER 100 LINEAR FEET OF TRENCH PER 8 -INCH COMPACTED -ILL THICKNESS. IT IS IMPERATIVE THAT A QUALIFIED FIELD TECHNICIAN BE ON-SITE DURING ALL SOIL PROCESSING AND PLACEMENT. PROVIDE JOINT REINFORCING AT 8" AT MASONRY BELOW GRADE, 2 ROWS AT 8" AT TOP AND BOTTOM OF OPENINGS, OWNER WILL EMPLOY AN INDEPENDENT TESTING LABORATORY TO PERFORM THE FOLLOWING TESTS AND SUBMIT TEST (EXTEND 24" EACH SIDE) AND 2 ROWS AT 8" AT BOND BEAMS. UNLESS NOTED OTHERWISE, WHERE MULTIPLE WYTHES OF REPORTS ON CAST -IN-PLACE CONCRETE: CONCRETE MASONRY ARE CONSTRUCTED AND/OR WHERE ADDITIONAL WYTHES OF CONCRETE MASONRY ARE ADDED TO ASTM C143 "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT CONCRETE." SLUMP SHALL NOT EXCEED LIMIT EXISTING WYTHES, EACH ADJACENT WYTHE SHALL BE TIED TO THE NEXT WYTHE WITH TYPICAL JOINT REINFORCING (NEW INDICATED ON APPROVED MIX DESIGN, OR 6" (WHICHEVER IS SMALLER) CONSTRUCTION FOR BOTH WYTHES) OR POST -INSTALLED TIES APPROVED BY ARCHITECT/ENGINEER (ADDITION TO EXISTING V OZ 0 CONSTRUCTION) WITH SPACING/LOCATIONS MATCHING THE SPACING/LOCATIONS FOR TYPICAL JOINT REINFORCING ASTM C39 'STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS." CYLINDERS DESCRIBED IN THE GENERAL NOTES. LL`� SHALL BE T KEN FOR EACH MIX DESIGN USED AND FOR EVERY 50 CUBIC YARDS OF CONCRETE PLACED TEST CYLINDERS CONCRETE MASONRY UNITS SHALL BE CUT BELOW CONCRETE BEAMS OR BOND BEAMS AS REQUIRED IN ORDER TO GET CONTINUOUS BEAM OR BOND BEAMS AT THE PROPER ELEVATION. ALL CELLS BELOW GRADE AND SLAB ON GRADE SHALL BE GROUTED. HORIZONTAL BEAMS, BOND BEAMS AND REINFORCING SHALL BE DISCONTINUOUS AT CONTROL JOINTS. 16" DEEP BOND BEAMS MAY BE CONSTRUCTED OF 8" U BLOCK BELOW AND 8" STANDARD BLOCK ABOVE WITH BREAK AWAY TOP PART OF WEB. SEE ARCHITECTURAL DRAWINGS FOR LAYING MASONRY AND LOCATION OF OPENINGS. ARCHITECT SHALL BE RESPONSIBLE FOR THE DESIGN OF ALL FLASHING. FACE SHELLS OF BED JOINTS SHALL BE FULLY MORTARED. WEBS SHALL BE FULLY MORTARED IN ALL COURSES OF PILASTERS, PIERS, COLUMNS, IN THE STARTING COURSE ON FOUNDATIONS WHERE ADJACENT CELLS/CAVITIES ARE TO BE GROUTED, & WHERE OTHERWISE NOTED. SHOP DRAWINGS DESIGN OF PRE-ENGINEERED SYSTEMS SPECIFIED IN THE CONTRACT DOCUMENTS WHICH ARE DESIGNED/ENGINEERED BY OTHERS IS THE SOLE RESPONSIBILITY OF THE DELEGATED ENGINEER. SUBMITTALS OF SUCH SYSTEMS SHALL BE SEALED BY AN ENGINEER LICENSED IN THE PROJECT STATE. STRUCTURAL DRAWINGS INDICATE TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. SHOP DRAWINGS SHALL DETAIL ALL CONDITIONS IN ACCORDANCE WITH SPECIFIED STANDARDS AND THE SPECIFIC REQUIREMENTS OF THIS PROJECT AS INDICATED IN THE PROJECT DOCUMENTS. THE CONTRACTOR SHALL SUBMIT, AS REQUIRED, PRINTS OF SHOP DRAWINGS FOR ALL FABRICATED MATERIALS TO ARCHITECT FOR REVIEW. REVIEW OF SHOP DRAWINGS BY THE ARCHITECT/ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF THOSE SHOP DRAWINGS. SHOP DRAWINGS REQUIRING A SPECIAL ENGINEERING DESIGN BY THE FABRICATOR SHALL BE STAMPED BY A REGISTERED ENGINEER OF RECORD IN THE STATE IN WHICH CONSTRUCTION WILL OCCUR BEFORE SUBMITTING FOR REVIEW BY THE ARCHITECT/ENGINEER. COMPLETE SHOP DRAWINGS FOR CONSTRUCTION OF ALL APPLICABLE SPECIALTY ITEMS INCLUDING, BUT NOT LIMITED TO, PRECAST CONCRETE, CURTAIN WALL GLAZING SYSTEMS, LIGHT GAGE STEEL FRAMING, ORNAMENTAL GUARDRAILS, SKYLIGHTS, AND STAIRS SHALL BE SEALED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THIS BUILDING SHALL BE CONSTRUCTED AND SHALL BE AVAILABLE AT THE JOB SITE DURING TIMES OF INSPECTION. THE OWNER WILL NOT PAY FOR ADDITIONAL CHARGES DUE TO RE -DETAILING FEES ASSOCIATED WITH A THREE-DIMENSIONAL DETAILING PROGRAM. THE DETAILER SHALL ESTIMATE AND INCLUDE ANY COSTS IN THE BASE BID ASSOCIATED WITH RE -DETAILING FEES AS A RESULT OF CHANGES AND/OR REVISIONS MADE TO THE SHOP DRAWINGS DURING THE SHOP DRAWING REVIEW. ENGINEER SHALL BE FOR CONFORMANCE WITH CONTRACT DOCUMENTS WITH REGARD TO THE ARRANGEMENT AND SIZES OF MEMBERS SHOWN ON THE STRUCTURAL CONTRACT DOCUMENTS AND THE DELEGATED ENGINEER INTERPRETATION OF THE DESIGN INFORMATION INCLUDED IN THE CONTRACT DOCUMENTS. SUCH REVIEW BY THE STRUCTURAL ENGINEER SHALL NOT IMPLY ANY RESPONSIBILITY FOR THE ACTUAL DESIGN OF SUCH SYSTEMS. CONTRACTOR HAS FULL RESPONSIBILITY FOR DIMENSIONAL ACCURACY AND CONFORMANCE WITH THE INFORMATION CONTAINED IN THE CONTRACT DOCUMENTS. SEE GENERAL NOTES FOR DESIGN CRITERIA AND ADDITIONAL REQUIREMENTS. FOOTINGS, HOLDDOWNS, FASTENERS, ETC. INDICATED WITHIN WHICH SUPPORT A PRE-ENGINEERED ITEM ARE PRELIMINARY AND SUBJECT TO CHANGE AFTER REVIEW OF THE PRE-ENGINEERED SHOP DRAWINGS. THESE SHOP DRAWINGS SHALL ALSO BE SUBMITTED TO THE BUILDING DEPT. AS A DEFERRED SUBMITTAL TO THE PERMIT DOCUMENTS. PRE-ENGINEERED STEEL STAIRS HANDRAILS & GUARDRAILS COMPLY WITH NAAMM, NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS, "METAL STAIR MANUAL" HANDRAILS AND GUARDRAILS SHALL BE DESIGNED FOR THE REQUIREMENTS OF 1607.7 OF THE REFERENCED BUILDING CODE. HANDRAILS & SUPPORTING STRUCTURE SHALL BE CAPABLE OF WITHSTANDING A 200 LB POINT LOAD OR 50 LB/FT LINE LOAD APPLIED IN ANY DIRECTION AT ANY POINT ON THE RAIL AND TO THE REQUIREMENTS OF THE REFERENCED BUILDING CODE. ALL COMPONENTS SHALL BE DESIGNED AND DETAILED BY THE FABRICATOR FOR A MINIMUM 100 PSF LIVE LOAD, 2000 LB. CONCENTRATED LOAD AND L/360 MAX. DEFLECTION. MINIMUM SIZES SHALL BE AS FOLLOWS: 1. METAL PANS: 14 GA. (UNLESS NOTED OTHERWISE) 2. STRINGERS: C12x20.7 (UNLESS NOTED OTHERWISE) AT THE FOLLOWING AGES: t CYLINDER AT 3 DAYS, I CYLINDER AT 7 DAYS, 2 CYLINDERS AT 28 DAYS -OR- HOLD ONE RESERVE CYLINDER TO BE TESTED AS REQUESTED BY THE ENGINEER. IF REQUIRED 28 DAY STRENGTH IS ACHIEVED, THE RESERVE CYLINDER MAY BE DISCARDED. ALL CONCRE E TESTS INCLUDING AIR CONTENT, SLUMP, AND TEST CYLINDERS SHALL BE TAKEN AT THE POINT OF DISCHARGE ND FROM THE DISCHARGE END OF PUMP HOSE WHEN CONCRETE IS PUMPED. rU3 1 -11N3 1 H ACU MVO nvr-%O 1N L U1%4k RG 1 G EXPANSION ANCHORS AS SHOWN ON CONTRACT DOCUMENTS SHALL BE HILTI KWIK BOLT 3 ANCHORS MANUFACTURED BY HILTI FASTENING SYSTEMS, WEDGE -ALL ANCHORS MANUFACTURED BY SIMPSON STRONGTIE COMPANY, POWER -STUD ANCHORS MANUFACTURED BY POWERS FASTENERS, TRUBOLT WEDGE ANCHORS MANUFACTURED BY ITW RAMSET/RED HEAD OR APPROVE EQUAL. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE PER MANUFACTURER'S REQUIREMENTS UNLESS NOTED OTHERWISE. ADHESIVE ANCHORS AS SHOWN ON CONTRACT DOCUMENTS SHALL CONSIST OF AN ALL -THREAD GRADE 36 STEEL ANCHOR WITH HY150 MAX INJECTION ADHESIVE (HIT HY20 INJECTION ADHESIVE FOR MASONRY CONSTRUCTION WITH VOIDS) SUPPLIED BY HILTI FASTENING SYSTEMS, EPDXY-TIE SET EPDXY ADHESIVE SUPPLIED BY SIMPSON STRONGTIE COMPANY, EPCON G5 EPDXY ADHESIVE SUPPLIED BY ITW RAMSET/RED HEAD OR APPROVED EQUAL. INSTALL IN ACCORDANCE WITH THE MANUFA-_TURER'S RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE PER MANUFACTURER'S REQUIREMENTS UNLESS NOTED OTHE ZWISE. POST -INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE DRAWINGS. CONTRACTOR SHALL OBTAIN APPROVAL FROM ENGINEER OF RECORD PRIOR TO USING POST INSTALLED ANCHORS FOR MISSING OR MISPLACED CAST -IN-PLACE ANCHORS. CARE SHALL BE GIVEN TO AVOID CONFLICTS WITH EXISTING REBAR. HOLES SHALL BE DRILLED AND CLEANED PER THE MANUFACTURER'S INSTRUCTIONS. ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATIO INSTRUCTIONS AT NOT LESS THAN MINIMUM EDGE DISTANCES AND/QR SPACING INDICATED IN THE MANUFACTURER'S LITERATURE. UNLESS SPECIFIED OTHERWISE, ANCHORS SHALL BE EMBEDDED IN THE APPROPRIATE SUBSTRATE WITH A MINIMUM EMBEDMENT OF 8 TIMES THE NOMINAL ANCHOR DIAMETER OR THE EMBEDMENT REQUIRED TO SUPPORT TH : INTENDED LOAD. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED, SHALL BE SUBMITTED T THE ENGINEER WITH CALCULATIONS THAT ARE PREPARED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER SHOWING THAT THE SUBSTITUTED PRODUCT WILL ACHIEVE AN EQUIVALENT CAPACITY USING THE APPROPRIATE DESIGN PROCEDURE REQUIRED BY THE BUILDING CODE. ADHESIVE FO REINFORCING DOWELS IN EXISTING CONCRETE SHALL BE EITHER THE HIT HY150 MAX INJECTION ADHESIVE SUPPLIED BY HILTI FASTENING SYSTEMS, EPDXY-TIE SET EPDXY ADHESIVE SUPPLIED BY SIMPSON STRONGTIE COMPANY, POWER -FAST EPDXY INJECTION GEL SUPPLIED BY POWERS FASTENERS, EPCON G5 EPDXY ADHESIVE SUPPLIED BY ITW RAMSET/RED HEAD OR APPROVED EQUAL. MINIMUM EMBEDMENT LENGTH SHALL BE 12 BAR DIAMETERS, UNLESS NOTED OTHERWISE. DEP RELATED DESIGN CRITERIA FEMA (BFE): FEMA FLOOD ZONE "X" DEP MONUMENT NUMBER: R048 100 YR. STORM ELEVATION: +16.4' NAVD (PER DEP MONUMENT) 100 YR. STORM DESIGN GRADE ELEVATION: +4.4' NAVD (PER DEP MONUMENT) BOTTOM OF ILING: -16.0' NAVD (TO BE VERIFIED BY GEOTHECHNICAL ENGINEER REPORT) BOTTOM OF OWEST HORIZONTAL STRUCTURAL ELEVATION. +16.4' NAVD. STRUCTURAL METAL CONNECTORS ARE IN CONFORMANCE WITH TABLE 1, FEMA - TECHNICAL BULLETIN 8 96. ALL CONCRETE REBAR COVERAGE HAS BEEN SPECIFIED AS REQUIRED BY ACI, TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF... THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS ESTABLISHED IN SECTION 6213-33, FLORIDA ADMINISTRATIVE CODE. THESE DESIGN PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE STANDARDS AND GUIDELINES ESTABLISHED IN FEMA P-55, I COASTAL CONSTRUCTION MANUAL. THE POOL HAS BEEN DESIGNED NOT TO INCREASE THE RISK OF DAMAGE OF ADJACENT DWELLINGS DURING A COASTAL STEEL STAIRS SHALL BE SLAB SUPPORTED USING 4" DIAMETER STANDARD PIPE POSTS AS NEEDED. PROVIDE DETAILS Sol STORM EVENT AS REQUIRED BY F.A.C. 6213-33 AND FEMA 55, CHAPTER 9.5.3. THAT STAIR CAN BE ASSEMBLED AND INSTALLED IN PROPER SEQUENCE WITH ADJACENT WORK. METAL PAN STAIR TREADS AND LANDINGS SHALL HAVE NOT LESS THAN 2" NOR MORE THAN 3" OF CONCRETE FILL FOR WALKING SURFACES. COORDINATE WITH ARCHITECTURAL DRAWINGS & MEET ALL APPLICABLE LOCAL BUILDING CODES, PLYWOOD WALL SHEATHING: 15/32" APA RATED OSB SHEATHING, 32/16. PANELS SHALL BE ORIENTED PER 1/S703. THE FIRST 4'-0" OF SHEATHING AT THE FOUNDATION SHALL BE ZIP PANEL TYP. THROUGHOUT. MINIMUM SIZE OF CONNECTION SHALL BE 8d COMMON NAILS TO WOOD. MAXIMUM SPACING OF CONNECTION SHALL BE 6" O.C. EDGE & 6" O.C. FIELD. SEE PLAN FOR INCREASED NAILING REQUIREMENTS AT SHEARWALLS. PLYWOOD FLOOR DECKING: 23/32" APA RATED TONGUE AND GROOVE OSB DECKING, 48/24 . LONG SIDE OF PLYWOOD PANEL SHALL BE PERPENDICULAR TO THE SUPPORT WITH THE END JOINT OF THE PANEL ALIGNED WITH THE CENTER OF THE TWO ADJACENT PANELS (NO CONTINUOUS PANEL JOINTS). PANELS SHALL BE CONTINUOUS OVER TWO OR MORE SPANS. MINIMUM SIZE OF CONNECTION SHALL BE 10d COMMON NAILS TO WOOD. MAXIMUM SPACING OF CONNECTION SHALL BE 6" O.C. EDGE & 6" O.C. FIELD. DECKING SHALL ALSO BE GLUED TO THE SUPPORTING FLOOR TRUSSES.. PLYWOOD ROOF SHEATHING: 19/32" APA RATED OSB SHEATHING, 32/16 (EXPOSURE 1). LONG SIDE OF PLYWOOD PANEL SHALL BE PERPENDICULAR TO THE SUPPORT WITH THE END JOINT OF THE PANEL ALIGNED WITH THE CENTER OF THE TWO ADJACENT PANELS. (NQ CONTINUOUS PANEL JOINTS). PANELS SHALL BE CONTINUOUS OVER TWO OR MORE SPANS. MINIMUM SIZE OF CONNECTION SHALL BE 0.113x2)/2" RINGSHANK NAILS Q 6" O.C. EDGE & 6" O.C. FIELD (AT GABLE ENDS DECREASE EDGE NAIL SPACING TO 4" O.C. WITHIN 4'-0" OF ROOF EDGE). SUITABLE EDGE SUPPORT SHALL BE PROVIDED AS RECOMMENDED BY THE AMERICAN PLYWOOD ASSOCIATION BY USE OF PANEL CLIPS OR LUMBER BLOCKING BETWEEN JOISTS. PANEL END JOINTS SHALL OCCUR OVER FRAMING. PLYWOOD PANELS SHALL BE BLOCKED WITH 2x4 (MIN. U.N.O.) AT PERIMETER OF ROOF AND AT DIRECTIONAL CHANGES. WOOD FRAMING NATIONAL FOREST PRODUCTS ASSOCIATION, AF & PA NDS -05, WITH 2005 SUPPLEMENT, AND AF&PA SPECIAL DESIGN PROVISIONS FOR WIND & SEISMIC, SDPWS-05. T WHERE ALL LUMBER, EXCEPT SPECIFICALLY NOTED L OTHERWISE, W SE, SHALL I BE MILL SIZED AND SURFACED ON (4) SIDES. ALL SHALL BE STRAIGHT STOCK, FREE FROM WARP OR CUP, AND SINGLE LENGTH PIECES. SPLICES WILL NOT BE PERMITTED EXCEPT WHERE SPECIFICALLY SO DETAILED OR AS DIRECTED BY THE ENGINEER. EACH PIECE OF STRUCTURAL LUMBER, SHEATHING AND TIMBER SHALL BE MARKED WITH THE GRADE BY SUCH COMPETENT AND RELIABLE ORGANIZATION WHOSE REGULAR BUSINESS IS TO ESTABLISH LUMBER GRADES. UNLESS NOTED OTHERWISE, USE SPRUCE -PINE -FIR (SPF) OR SOUTHERN PINE (SYP), 19% MAX. MOISTURE CONTENT, AS FOLLOWS: 1. DOUBLE TOP PLATES AND SILL PLATES SHALL BE (SPF#2). 2. PLATES IN CONTACT WITH CONCRETE OR CMU SHALL BE (SYP#2) P.T. 3. SILL PLATE ANCHORS PER FOUNDATION PLAN. 4. MIN. OF (SPF) UTILITY GRADE FOR INTERIOR NON-BRG. TOP PLATES. 5. USE (SPF#2) OR BETTER FOR ALL WALLS IN THESE PLANS. 6. SPACE STUDS AT 24" O.C. IN NON -LOAD BEARING WALLS. 7. BEAMS AND HEADERS (SYP#2). 8. LOAD BEARING STUDS, & EXTERIOR STUDS (SEE WALL SCHEDULE) 9. SUB -PURLINS, PLATES, BLOCKING (SPF #2) ALL WALLS SHALL BE BALLOON FRAMED FULL HEIGHT TO ROOF OR FLOOR BEARING ELEVATION, UNLESS NOTED OTHERWISE ON PLAN. SPRUCE PINE FIR #2 SPECIFICATIONS: Fb=775 PSI, Fc(PARALLEL)= 1000 PSI, Fc=(PERP)=335 PSI, Fv=135 PSI, Ft=350 PSI, E=1100 KSI SOUTHERN PINE #2 SPECIFICATIONS PER LATEST SOUTHERN FOREST PRODUCTS ASSOCIATION (SFPA) ANY WOOD IN CONTACT WITH CONCRETE, MASONRY, OR SOIL, SHALL BE PRESSURE TREATED. METAL CONNECTORS SHALL BE FASTENED IN ACCORDANCE WITH THE MANUF. INSTRUCTIONS TO DEVELOP THE MAXIMUM PUBLISHED CAPACITY. ALL WOOD -TO -WOOD CONNECTIONS SHALL EMPLOY METAL ANCHORS. NO TOE OR END NAILING SHALL BE PERMITTED (UON), EXCEPT FOR AT TOP AND BOTTOM PLATES IN WALLS. METAL CONNECTORS SHALL BE FASTENED IN ACCORDANCE WITH MANUF. INSTRUCTIONS TO DEVELOP THE PUBLISHED CAPACITY. ALL CONNECTORS SHALL BE G90 GALV. STEEL. ALL ANCHORS IN CONTACT WITH PRESSURE TREATED, FIRE -RETARDANT OR WOLMANIZED WOOD SHALL BE COATED WITH G185 ZINC COATING. ALL OTHER ANCHORS MAY BE COATED WITH G90 COATING. THE QUANTITY OF WALL STUDS DISPLACED OR CUT FOR AN OPENING SHALL BE PLACED ADJACENT TO AND ATTACHED TO JAMBS, HALF ON EACH SIDE OF THE OPENING. WHERE CONNECTIONS ARE NOT SHOWN ON THE DRAWINGS, COMPLY WITH NAILING SCHEDULE IN THE BUILDING CODE. ALL NAILS AT NON -AIR CONDITIONED/HEATED AREAS SHALL BE GALVANIZED. TOE NAILS SHALL BE DRIVEN AT AN ANGLE OF 30` TO THE PIECE AND BE STARTED AT 1/3 THE NAIL LENGTH FROM THE END OF THE PIECE. ALL BOLTS SHALL BE FURNISHED WITH STANDARD NUT WASHER. FASTENERS IN CONTACT WITH TREATED WOOD, INCLUDING BOLTS AND NAILS AT SILL PLATES SHALL BE HOT -DIPPED GALV. OR STAINLESS STEEL IN ACCORDANCE WITH REQ. OF SECTION 2304.9.5 OF THE BUILDING CODE. ALL NAILS TO BE G90 GALVANIZED (G185 GALVANIZATION FOR NAILS IN CONTACT WITH TREATED WOOD). COORDINATE BLOCKING LOCATION WITH SHEATHING EDGES AS REQUIRED. ALL NAILS SHALL BE COMMON WIRE NAILS. MULTIPLE STUD OR SOLID COLUMNS SHALL BE CONTINUOUS FROM FRAMING LEVEL, WHERE SHOWN, TO THE FOUNDATION. THIS WILL REQ. SOLID BLOCKING WITHIN THE FLOOR FRAMING EQUAL TO THE COLUMN DIMENSION. UNLESS OTHERWISE FASTENED, CONNECT COLUMNS ABOVE AND BELOW EACH FRAMING LEVEL WITH SIMPSON CMST14 STRAP (WITH NAILS/LAP ABOVE AND BELOW FRAMING LEVEL PER STRAP SPECIFICATIONS) AND ANCHOR COLUMN TO FOUNDATION WITH SIMPSON HTT16 HOLD-DOWN w/ 5/8" DIAMETER x 6" EMBED. DEPTH EPDXY ANCHOR. MULTIPLE STUD PACK COLUMNS SHALL BE CONNECTED LATERALLY TO ONE ANOTHER PER DETAIL INDICATED HEREIN. MINIMUM CONNECTIONS SHALL BE AS FOLLOWS (UON): BEAMS - (1) SIMPSON HTS16 EACH END TYPICAL. BEAM TO POST - CMST14 STRAP WRAPPED ACROSS TOP OF BEAM END AND DOWN POST WITH NAILS/LAP ON TOP OF BEAM AND DOWN POST AS SPECIFIED FOR STRAP. WALL SHEATHING NOTED ON STRUCTURAL DRAWINGS OR SCHEDULES SHALL BE ATTACHED DIRECTLY TO THE FACE OF FRAMING MEMBERS. SEE ARCHITECTURAL DRAWINGS FOR ALL NON-STRUCTURAL SHEATHING REQUIREMENTS. ADDITIONAL SHEATHING REQUIRED BY ARCHITECTURAL DRAWINGS SHALL BE ATTACHED TO THE OUTSIDE FACE OF STRUCTURAL SHEATHING. WALL FRAMING MAY BE PANELIZED (WITHOUT GYPSUM WALLBOARD OR SHEATHING). SUBMIT PANEL DRAWINGS FOR REVIEW. TIMBER FASTENING SHALL BE PER FBC "MINIMUM FASTENING SCHEDULE" UNLESS NOTED AS GREATER ON DRAWINGS. CONNECTORS TO BF SIMPSON OR APPROVED ALTERNATE, WITH MINIMUM CAPACITY AS NOTED. SEE PLANS. ALL NAILS SHALL BE COMMON WIRE NAILS. � m m O� N / d/- LL- U) Q o z �. Ch .� o U- ujd C V OZ 0 N fi-- 0) 4 LL`� +p uj _..,. 0 W c� z u..i ao Q z V O ti S o� U 0 d0 �h .M.��. N 9 c.> H 0 � m m O� N / d/- LL- z C Q o z �. O .� < U- ujd V OZ 0 W m UJI Z LL`� +p uj _..,. 0 W z u..i ao Q z V O o GENERAL NOTES 50.1 WOOD FRAMINGCONTINUED) ROUGH HARDWARE, JOIST HANGERS, STRAPS, HOLDOWNS, ETC. SHALL BE MANUF. BY "SIMPSON STRONG -TIE" COMPANY OR APPROVED EQUAL. THE MAX. SIZE AND NUMBER OF FASTENERS SPECIFIED BY THE MANUFACTURER SHALL BE USED UNLESS NOTED OTHERWISE. BLOCKING AND FIRESTOPPING TO BE INSTALLED AS REQUIRED TO SUPPORT ALL ITEMS OF FINISH SUCH AS BULKHEADS AND BUCKS. PROVIDE FIREBLOCKING TO CUT OFF ALL CONCEALED DRAFT OPENINGS, BOTH VERTICAL AND HORIZONTAL, BETWEEN CEILING AND FLOOR AREAS (AS REQUIRED BY BUILDING OFFICIAL AND ARCHITECT). BOLTS (IF APPLICABLE) SHALL BE INSTALLED IN HOLES BORED WITH A BIT 1/16" LARGER THAN THE DIAMETER OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NUTS SHALL BE PULLED TIGHT AND AGAIN CHECKED AND TIGHTENED JUST PRIOR TO ENCLOSING BOLTED MEMBERS. COUNTER BORE FOR BOLTED HEADS OR NUTS ONLY WHERE SO INDICATED ON THE DRAWINGS AND THEN TO SUFFICIENT DEPTH TO HOUSE THE BOLT HEAD OR NUT AND WASHER. CUT OFF EXCESSIVE BOLT PROJECTION WHERE NECESSARY. NICK THREADS TO PREVENT LOOSENING. ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH MASONRY, CONCRETE OR SOIL SHALL BE PRESSURE -TREATED. PT LUMBER INDICATED IN SECTIONS PRESERVED WITH SODIUM BORATE (DOT-DISODIUM OCTABQRATE TETRA HYDRATE). IF HOWEVER, ACQ OR NON -DOT BORATE PRESERVATIVE TREATMENT IS USED, ALL ATTACHED FASTENERS SHALL BE HOT DIPPED GALVANIZED. IF ACZA PRESERVATIVE IS USED, ALL ATTACHED FASTENERS SHALL BE STAINLESS STEEL. PRE--ENGINEEREED WOOD FLOOR & ROOF TRUSSES "GANG -NAIL" PRE-ENGINEERED WOOD TRUSSES ARE TO BE CONSTRUCTED WITH METAL PLATE CONNECTORS AND DESIGNED BY A DELEGATED ENGINEER. TRUSSES SHALL COMPLY WITH NEPA, TPI, AND AITC 100. THE TRUSS MANUFACTURER SHALL PROVIDE DESIGN CALCULATIONS AND SHOP DRAWINGS SIGNED AND SEALED BY A STRUCTURAL ENGINEER (CONTRACTED BY TRUSS MANUFACTURER) FOR REVIEW PRIOR TO FABRICATION. DESIGN, CONSTRUCTION, AND INSTALLATION SHALL MEET ALL APPLICABLE REQUIREMENTS OF THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION AND OF THE TRUSS PLATE INSTITUTE. PROVIDE ALL REQ. BLOCKING AND BRACING REQUIRED BY THE MANUFACTURER FOR CONSTRUCTION AND ERECTION IN ADDITION TO BLOCKING SHOWN ON THE STRUCTURAL DETAILS. MEMBERS OF A COMPLETED TRUSS ARE NEVER TO BE NOTCHED OR CUT. THE DESIGN SHALL ACCOUNT FOR ALL UNIFORM LOADS AND EQUIPMENT LOADS. CONTACT THE STRUCTURAL ENGINEER FOR UNIFORM LOADING AND REQUIREMENTS IF REQ. CONTRACTOR SHALL VERIFY THAT ADEQUATE TRUSS BEARING IS INSTALLED AT ALL TRUSSES AS INDICATED IN THE TRUSS SHOP DRAWINGS. ALL TRUSS -TO -TRUSS CONNECTIONS AND TRUSS PROFILES ARE THE RESPONSIBILITY OF THE DELEGATED TRUSS ENGINEER. PRE-ENGINEERED WOOD TRUSSES SHALL BE BRACED IN ACCORDANCE WITH TRUSS PLATE INSTITUTE'S "HANDLING, INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES, HIB -91" AND " BUILDING COMPONENT SAFETY INFORMATION BOOKLET BCSI 1-03" AND RELATED SUMMARY SHEETS. TRUSSES TO BE SPACED @ 24" O.C. (UNLESS OTHERWISE SHOWN). SEE PLANS FOR TRUSS LOCATION AND SPANS AS WELL AS SPECIAL TRUSS LOCATIONS REQUIRED FOR MECHANICAL UNITS AT ROOMS. ACTUAL TRUSS SPACING TO BE USED TO DETERMINE UNIFORM LOADS/FOOT. WOOD TRUSSES ALONG A VERTICAL PLANE OF THE BUILDING SHALL BE CONTINUOUS. TRUSSES MAY BE SPLICED FOR SHIPPING PURPOSES AND CONNECTED IN THE FIELD WITH METAL CONNECTOR PLATES. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. WOOD TRUSSES SHALL BE FULLY ENGINEERED AND FABRICATED BY THE MANUFACTURER AND SHALL BEAR THE SEAL AND SIGNATURE OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE CONSTRUCTION IS TO OCCUR. SHOP DRAWINGS SHALL BE SUBMITTED AND SHALL INCLUDE TRUSS SPACING (24" MAX.), SIZE OF MEMBERS, CONNECTIONS, AND BRACING. DESIGN SHALL CONSIDER LL, DL, AND ALL SPECIAL LOADS FROM MECHANICAL AND PLUMBING. CALCULATIONS SHALL ALSO BE SUBMITTED AND SHALL BEAR THE SEAL OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE CONSTRUCTION IS TO OCCUR. SPECIAL LOADS FROM MECH./PLUMBING OR OTHER EQUIPMENT HAVE NOT BEEN CONSIDERED AND SHALL BE COORDINATED BY THE TRUSS DESIGNER. TRUSSES SUPPORTING THESE SPECIAL LOADS SHALL BE DESIGNED FOR THESE LOADS IN ADDITION TO THE TYPICAL UNIFORM LOADS. CONCENTRATED LOADS SHALL BE SUPPORTED AT PANEL POINTS ONLY. ANY LOADS SUSPENDED FROM TRUSSES MUST BE APPLIED TO EACH TRUSS UNIFORMLY, SPACING OF HANGERS NOT TO EXCEED 2'-0" Q.C. IN ANY DIRECTION. ALL TRUSS SHOP DRAWINGS INCLUDING LATERAL BRACING DETAILS SHALL BE AVAILABLE AT THE JOBSITE DURING TIMES OF INSPECTION AND SHALL BEAR CLEAR INDICATION THAT THEY HAVE BEEN REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. GENERAL CONTRACTOR SHALL NOT CUT OR ALTER ANY TRUSS MEMBER. ALL TRUSS CONNECTORS TO BE G90 GALVANIZED STEEL. ALL NAILS/SCREWS USED AT CONNECTOR PLATES/ANCHORS SHALL BE G-90 GALVANIZED. FLOOR TRUSSES SHALL CONNECT TO BEARING WALLS WITH A MINIMUM OF (2)-16d TOENAILS. FLOOR TRUSSES SHALL CONNECT TO BEAMS AT FLUSH CONDITIONS WITH SIMPSON HANGERS AS SPECIFIED BY TRUSS DESIGNER. TRUSS MANUFACTURER SHALL COORDINATE WITH CONTRACTOR FOR LOCATIONS OF SQUARE PANELS FOR HVAC. FLOOR TRUSS WEB STIFFENERS ARE REQ. AT ALL INTERMEDIATE BEARING LOCATIONS AND WHEN TRUSSES ARE BEING SUPPORTED ON HANGERS. FLOOR TRUSSES SHALL BE FABRICATED AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. SEE MECHANICAL DRAWINGS AND ROOF PLAN FOR EQUIPMENT WEIGHTS, LOCATIONS AND ACCESS PATHS IN ROOF TRUSSES. SEE MECHANICAL DRAWINGS AND ROOF PLAN FOR EQUIPMENT WEIGHTS, LOCATIONS AND ACCESS PATHS IN ROOF TRUSSES. ACTUAL TRUSS SPACING TO BE USED TO DETERMINE UNIFORM LOADS/FOOT. ROOF TRUSSES SHALL BE CONNECTED AT THE BEARING AT EACH END AS FOLLOWS: WHERE THE ROOF TRUSSES BEARS ON A DOUBLE 2x PLATE, THE TRUSS SHALL BE CONNECTED WITH (2)-12D TOENAILS AND A SIMPSON H2.5A. WHERE THE ROOF TRUSS CONNECTS TO ANOTHER TRUSS OR BEAM, IT SHALL BE CONNECTED WITH A METAL TRUSS ANCHOR CAPABLE OF RESISTING GRAVITY AND WIND LOADS. (ANCHOR TO BE SELECTED AND DESIGNED BY TRUSS ENGINEER). TRUSS DESIGNER SHALL INDICATE THAT ALL HIPS, VALLEYS, AND RIDGES NOT SUPPORTED BY A TRUSS MEMBER SHALL HAVE A DOUBLE 2x8 FRAMING MEMBER SPANNING BETWEEN TRUSSES WITH SIMPSON CLIP CONNECTION EA. END. AMOUNT AND TYPE OF TRUSS UPLIFT STRAPPING SHALL BE VERIFIED W/ TRUSS ENGINEER'S SHOP DRAWINGS AND CALCULATION AND ADJUSTED ACCORDINGLY, AS NEEDED. ROOF TRUSSES, TRUSS GIRDERS, JOISTS AND BEAMS TO WALLS. ALL CONNECTIONS SPECIFIED HEREIN ARE MINIMUM CONNECTIONS AND WILL BE REVIEWED AND UPDATED BASED ON UPLIFT FORCES SUBMITTED ON THE TRUSS AND JOIST SHOP DRAWINGS. SINGLE SPAN ROOF TRUSSES - (1) SIMPSON H2.5A AT EACH END. TWO SPAN ROOF TRUSSES - (1) SIMPSON H2.5A AT EACH END AND (2) SIMPSON H2.5A AT INTERMEDIATE SUPPORTS (ONE EACH SIDE). TRUSS GIRDERS - (1) SIMPSON HTS16 EACH END TYPICAL. DESIGN BY TRUSS DESIGNER FOR NON -TYPICAL CONDITIONS. r"RG—GIV"IIVGG(C GU YYUUU rLUUIZ OZ rxuur IIRUJJLJ luuN 11114UL.0 PROPER ERECTION BRACING SHALL BE INSTALLED TO HOLD THE TRUSSES TRUE AND PLUMB AND IN SAFE CONDITION UNTIL PERMANENT TRUSS BRACING AND BRIDGING CAN BE SOLIDLY NAILED IN PLACE TO FORM A STRUCTURALLY SOUND FRAMING SYSTEM. ALL ERECTION AND PERMANENT BRACING SHALL BE INSTALLED AND ALL COMPONENTS PERMANENTLY FASTENED BEFORE THE APPLICATION OF ANY LOADS TO THE TRUSSES. ALL BRACING SHALL BE DESIGNED BY MANUFACTURER AND INDICATED ON SHOP DRAWINGS. CONTRACTOR SHALL COORDINATE WITH TRUSS FABRICATOR TO ENSURE THAT ALL BRACING IS PROVIDED INCLUDING BOTTOM CHORD BRACING BY WAY OF CEILING SHEATHING OR SPECIFIC BRACES AT PREDETERMINED LOCATIONS (AT DROPPED SUSPENDED CEILING). ALL PREFABRICATED WOOD TRUSSES ARE TO BE INSTALLED IN ACCORDANCE WITH BRACING WOOD TRUSSES COMMENTARY, "HANDLING AND ERECTING WOOD TRUSSES", AS PUBLISHED BY THE TRUSS PLATE INSTITUTE. PROVIDE STRONG BACK BRACING AT TRUSSES PER REQUIREMENTS FROM TRUSS DESIGNER. COMPONENT -TO -COMPONENT CONNECTIONS SHALL BE SPECIFIED ON PRE-ENGINEERED TRUSS DESIGN SUBMITTAL. ALL EXPOSED ITL. STRAPS AND HANGERS SHALL BE GALV. G185 (1.85 OZ/FT"2) OR BETTER. SIMPSON PRODUCTS SHALL BE IMAX GALV. HANGER AND STRAPS INSTALLED OVER ACQ OR ACZE PRESSURE TREATED LUMBER SHALL BE STAINLESS STEEL. ALL EXPOSED WOOD FASTENERS SHALL BE HOT DIPPED GALVANIZED TO MEET THE SPECIFICATIONS OF ASTM153 OR BETTER. FASTENERS INSTALLED INTO ACQ OR ACZE PRESSURE TREATED LUMBER SHALL BE STAINLESS STEEL. Y'ICt—LIVVIIVLLIC U MIJI.LLLMINLUUJ J IMUI..IUMLJ: PRE-ENGINEERED ALUMINUM CANOPY STRUCTURE DESIGNED BY OTHERS. CONTRACTOR SHALL SUBMIT SHOP DRAWING INDICATING CONNECTION POINTS, REACTIONS, & FASTENER REQUIREMENTS. CONTRACTOR SHALL COORDINATE ANY LOADING REQUIREMENTS WITH THE PRE-ENGINEERED WOOD ROOF TRUSSES. (TYPICAL) LAMINATED VENEER LUMBER SHALL BE 1.9E MICROLLAM LVL AS MANUFACTURED BY TRUSS JOIST MACMILLAN OR AN VED APPROEQU L. SIGNED AND SEALED SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. SHOP DRAWINGS SHALL INCLUDE SIZE, SPACING, BRACING AND ALL SUPPORT HANGERS. LAMINATED VEN ER LUMBER SHALL HAVE THE FOLLOWING PROPERTIES: ALLOWABLE BENDING STRESS 2600 PSI ALLOWABLE COMPRESSION PARALLEL TO GRAIN 2510 PSI ALLOWABLE HORIZONTAL SHEAR 285 PSI ALLOWABLE COMPRESSION PERPENDICULAR TO GRAIN 750 PSI MODULUS OF ELASTICITY 1,900,000 PSI SHEAR MODULUS OF ELASTICITY 118,750 PSI NOTCHES, HOLE OR CUTS SHOWN IN DETAIL 8/S700 ARE ALLOWED WITHOUT ADDITIONAL APPROVAL; MEMBER MODIFICATIONS ARE TO BE APPROVED BY THE STRUCTURAL ENGINEER. STRUCTURAL STEEL MATERIALS: STRUCTURAL STEEL CHANNELS, ANGLES, PLATES RECTANGULAR STEEL TUBES PIPES HIGH STRENGTH BOLTS ANCHOR BOLTS WELDING ELECTRODES A572 or A992 (50 KSI) A36 (36 KSI) A500 Gr. B. (46 KSI) A53 Gr. B A325N A307 or ASTM F1554 (36 KSI) E70XX DETAIL, FABRICATE, AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH AISC SPECIFICATION FOR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE AISC SPECIFICATION FOR STRUCTURAL STEEL FOR BUILDING - ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN, 14TH EDITION. WELDING FOR STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH AWS CODE D1.1 AND VISUALLY CONFORM TO AWS SECTION 6 AND TABLE 6.1. FABRICATION/ERECTION INSPECTIONS BY THE CONTRACTOR PER AWS D1.1 SECTION 6, SHALL BE BY ASSOCIATE/CERTIFIED INSPECTORS (ACI/CWI) PER AWS QC1 OR AWS B5.1. VERIFICATION INSPECTIONS SHALL BE BY A CERTIFIED WELDING INSPECTOR (WI) OR SENIOR WELDING INSPECTOR (SWI) PER AWS B5.1 WELDS SHALL BE MADE ONLY BY OPERATORS EXPERIENCED IN PERFORMING THE TYPE OF WORK INDICATED. WELDING SHALL BE DONE IN ACCORDANCE WITH APPROPRIATE WELD PROCEDURE SPECIFICATIONS (WPS'S) WELDERS SHALL BE FAMILIAR WITH THE APPLICABLE WPS'S. WELDS NORMALLY EXPOSED TO VIEW IN THE FINISHED WORK SHALL BE UNIFORMLY MADE AND GROUND SMOOTH. WHERE WELDING IS DONE IN PROXIMITY TO GLASS OR FINISHED SURFACES, SUCH SURFACES SHALL BE PROTECTED FROM DAMAGE DUE TO WELD SPARKS, SPATTER OR TRAMP METAL. WELDER QUALIFICATIONS AND (WPS) SHALL BE MAINTAINED AT THE SITE OF THE WORK AND SHALL BE READILY AVAILABLE FOR INSPECTION UPON REQUEST, BOTH IN THE SHOP AND IN THE FIELD A CERTIFIED WELD INSPECTOR (CWI) SHALL INSPECT AND DOCUMENT COMPLIANCE WITH THE FOLLOWING: CONFIRM WELDER QUALIFICATIONS PRIOR TO START OF WORK. REVIEW ALL (WPS) PRIOR TO START OF WORK.. CONFIRM MATERIALS IN FABRICATIONS CONFORM TO SPECIFICATIONS. OBSERVE JOINT PREPARATION, FIT -UP AND WELDER TECHNIQUE. IDENTIFY ALL MULTI -PASS FILLET WELDS, SINGLE PASS FILLET WELDS GREATER THAN 5/16" AND COMPLETE / PARTIAL JOINT PENETRATION GROOVE WELDED BUTT JOINTS THAT REQUIRED CONTINUOUS INSPECTION. VISUALLY INSPECT ALL WELDS PER AWS SECTION 6.5 AND TABLE 6.1 ALL WELDS SHALL BE 3/16" MINIMUM FILLET WELDS U.O.N. OR AS REQUIRED BY DESIGN. ALL OTHER STRUCTURAL GROUT SHALL BE SHRINKAGE RESISTANT NON -EXPANSIVE, NON- METALLIC GROUT WITH A MINIMUM 28 -DAY COMPRESSIVE STRENGTH OF 500OPS1 WHEN TESTED IN ACCORDANCE WITH ASTM C109. FORMS SHALL BE PLACED AROUND BASE PLATE AND THE STRUCTURAL GROUT SHALL BE POURED. NO DRY -DAMP PACKING. MANUFACTURER SHALL PROVIDE A COMPLETE SET OF DESIGN. CALCULATIONS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ARCHITECT/ENGINEER FOR REVIEW. PARALLEL STRAND LUMBER SHALL BE 2.0E PARALLAM PSL AS MANUFACTURED BY TRUSS JOIST MACMILLAN OR AN APPROVED EQUAL. SIGNED AND SEALED SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. SHOP DRAWINGS SHALL INCLUDE SIZE, SPACING, BRACING AND ALL SUPPORT HANGERS. PARALLEL STRAND LUMBER SHALL HAVE THE FOLLOWING PROPERTIES: ALLOWABLE BENDING STRESS 2900 PSI ALLOWABLE COMPRESSION PARALLEL TO GRAIN 2900 PSI ALLOWABLE HORIZONTAL SHEAR 290 PSI ALLOWABLE COMPRESSION PERPENDICULAR TO GRAIN 750 PSI MODULUS OF ELASTICITY 2,000,000 PSI SHEAR MODULUS OF ELASTICITY 125,000 PSI NOTCHES, HOLES OR CUTS SHOWN IN DETAIL 8/S700 ARE ALLOWED WITHOUT ADDITIONAL APPROVAL; ALL OTHER MEMBER MODIFICATIONS ARE TO BE APPROVED BY THE STRUCTURAL ENGINEER. WOLMANIZED PARALLEL STRAND LUMBER SHALL BE TREATED WITH CA -C PRESERVATIVE IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. MAXIMUM MOISTURE CONTENT AFTER TREATMENT AND DRYING SHALL BE 19%. PRIME: ALL STEEL SURFACES, BOTH EXPOSED AND CONCEALED ARE TO RECEIVE ONE SHOP COAT OF PAINT AND FIELD SPOT PRIME ALL WELDS, SCARS CONN., ETC., WHERE PAINT IS DAMAGED. ALL GALVANIZED STEEL SHALL HAVE ALL WELDS, SCARS, ETC., RE -GALVANIZED IF DAMAGED. DEVIATION FROM THE CONNECTION DETAILS DEPICTED IN THE CONTRACT DOCUMENTS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE STRUCTURAL ENGINEER. STRUCTURAL ENGINEER SHALL BE COMPENSATED BY THE CONTRACTOR FOR THE COST INVOLVED IN THE REDESIGN OF CONNECTIONS FOR THE CONVENIENCE OF THE CONTRACTOR. GENERAL NOTES 50.2 m Cf) N tL- Z C d z v d � W �d = V 06 v N L d ' A 1 o- o l 00 �: d d V O Z U O on, 44o o g � F GENERAL NOTES 50.2 m Cf) N tL- Z C d z �.._.. d O w W �d = V Qw Z v z L d ' A 1 z w l 00 �: d d V O Z GENERAL NOTES 50.2 —In—/ M PILE LAYOUT PLAN SCALE: 1/4" = l'—O" z Cf) cf) 06 W N0 CLI U.0 Z cf) z < IV > _ 0 ccl z lu z 0 Lu La 0 < o MAW.- ap, C) z 0 T_ a) > c: z Cf) cf) W N0 CLI U.0 Z cf) z < IV > _ 0 O z lu z 0 Lu La 0 < Z lu Luu-1 C) z 0 T_ PILE LAYOUT PLAN S1.OA 4" UN—REINFORCED CONC. SLAB ON GRADE. SAW—CUT 5'x5 PATTERN 20'—O)* TT/SLAB + 15.55' 2 NAVD SLOPE 121-0$$ SLAB DIMENSION PLAN SCALE: 1/4" = V-0" --------------- c cl U) z 0 ON CLI 06 Cf) U. 0) N z 4I CS4 W U > 1� 0 o 00 Z ry z C) a) z U-1 U a) d 0 Hw z Q) 0 < Qo N 2: C) z 0 W CLI Z Cf) U. 0 z W U > 1� 0 o Z ry z C) Lu z U-1 U 0 z Q) 0 Qo M 0 M19 L.P. SLA NAVD Cl: 12x12 CONC. COLUMN w/(4)#5 & #3 TIES AT 6" O.C. CONC. COLUMN SHALL EXTEND TO UNDERSIDE OF 2ND FLOOR WOOD FRAMING. WOOD POST BY BUILDER, VSEE 5/S1.01 ---------------------------- T:r --------------------------- FOUNDATION PLAN SCALE: 1/4" = l'—O" FOUNDATION LEGEND 0 14" DIAMETER AUGERCAST PILE, SEE 1/S1.01 INDICATES GRADE BEAM, SEE SHEET Sl.Ol FOR REINFORCEMENT INDICATES DETAIL NUMBER �$ �-O INDICATES BUILDING AND SHEET NUMBER T/SLAB TOP OF SLAB ELEVATION NOTES: 1. TOP OF SLAB ELEVATION VARIES, SEE PLAN. 2. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, FLOOR SLOPES AND STEPS NOT SHOWN. 3. COORDINATE TOP OF SLAB WITH ARCHITECTURAL PLANS PRIOR TO CONSTRUCTION NOTES: 1. THIS FOUNDATION PLAN ONLY CONVEYS STRUCTURAL INFO RELATED TO THE FOUNDATION. FOR GENERAL FEATURES, DIMENSIONS, CONDUITS, ELECTRICAL EMBEDS, STEP HEIGHTS, ECT., SEE ARCH. PLAN. ARCHITECTURAL PLAN SHOWN HERE IN FOR REFERENCE ONLY. 2. FTGS. & FND. SHALL BE IN ACCORDANCE w/ LOCAL BUILDING CODES. 3. SOIL COMPACTION AND FILL SHALL BE COMPACTED TO A MIN. OF 95% MODIFIED PROCTOR IN ACCORDANCE WITH ASTM D 1557. 4. TYP. GRADE BEAM IS GB -1 U.O.N., SEE DETAIL 2/S1.1 FOR REINFORCING. T/CMU WALL 0) (\I (V0- Ll 1 U) cf) z a) 09 0 u- 06 NAVQ o I Z u_J z (ID 0Z iYi t} Lu I 77777 _V z Lu UJ _j 00 a) z Q) " 4 UN --REINFORCED 0 T/SLAB a) o ONC. SLAB ON GRADE. CONC.C SL C) 0 S W_CUT 'N SAW—CUT 5'x5' PATTERN] 2 NAVD § Q ^4 S1.01y" Cl: 12x12 CONC. COLUMN w/(4)#5 & #3 TIES AT 6" O.C. CONC. COLUMN SHALL EXTEND TO UNDERSIDE OF 2ND FLOOR WOOD FRAMING. WOOD POST BY BUILDER, VSEE 5/S1.01 ---------------------------- T:r --------------------------- FOUNDATION PLAN SCALE: 1/4" = l'—O" FOUNDATION LEGEND 0 14" DIAMETER AUGERCAST PILE, SEE 1/S1.01 INDICATES GRADE BEAM, SEE SHEET Sl.Ol FOR REINFORCEMENT INDICATES DETAIL NUMBER �$ �-O INDICATES BUILDING AND SHEET NUMBER T/SLAB TOP OF SLAB ELEVATION NOTES: 1. TOP OF SLAB ELEVATION VARIES, SEE PLAN. 2. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, FLOOR SLOPES AND STEPS NOT SHOWN. 3. COORDINATE TOP OF SLAB WITH ARCHITECTURAL PLANS PRIOR TO CONSTRUCTION NOTES: 1. THIS FOUNDATION PLAN ONLY CONVEYS STRUCTURAL INFO RELATED TO THE FOUNDATION. FOR GENERAL FEATURES, DIMENSIONS, CONDUITS, ELECTRICAL EMBEDS, STEP HEIGHTS, ECT., SEE ARCH. PLAN. ARCHITECTURAL PLAN SHOWN HERE IN FOR REFERENCE ONLY. 2. FTGS. & FND. SHALL BE IN ACCORDANCE w/ LOCAL BUILDING CODES. 3. SOIL COMPACTION AND FILL SHALL BE COMPACTED TO A MIN. OF 95% MODIFIED PROCTOR IN ACCORDANCE WITH ASTM D 1557. 4. TYP. GRADE BEAM IS GB -1 U.O.N., SEE DETAIL 2/S1.1 FOR REINFORCING. z c: cf) 0) (\I (V0- Ll 1 U) cf) z a) 09 0 u- 06 0 o Z u_J z (ID 0Z iYi t} Lu ul z Lu UJ 00 a) z Q) 0 a) o C) 0 > > § Q z cf) (\I (V0- Ll 1 Z 0 cf) z 09 u- > 0 o Z u_J z (ID 0Z Lu ul z Lu UJ 00 z Q) 0 o o 0 LLJ O LLJ D (s) F) z 0 (s) Lu cn (s) Q.LLLLL) are Q14"0 AUGER CAST PILE vwl 7—#5 w/ #3 TIES Q 12" oc PILE SECTION GEOTECH ENGINEER TO VERIFY PILE DEPTH. SEE NOTE ON SHEET S1.0 TYPICAL PILE ELEVATION SCALE: 1/4" = 1'-d" STAIR POST BY BUILDER FRAME WALL BOND BEAM W/ 1—#5 EXTEND BARS TO WITHIN CONTINUOUS _ 100 YR. STORM ELEV r 3" OF TOP OF GRADE i'TtL. +16.4 NAVD I I BEAM w/6" 90' HOOK (TYP) I' i I I I 1 TOP OF SLAB 1 i T PILE VAR S I I L. SEE PLAN SEE PLAN I I I f i 4" BREAK -AWAY SLAB I I I SHORE PERPENDICULAR i I TOP OF G. BEAM CMU W/ #5 @ 24" O.C. F--` — '--� GROUT ALL CELLS SOLID I • i L. SEE PLAN I 1 I � I I ^1 1 • 0-- M 18x18 TYPICAL GRADE BEAM REINFORCING: 2—#6 TOP & STOP GRADE BEAM -H BOT. W/#3 TIES @ 12" OC V-1201 BOTTOM REINFORCING AT PILE 14"o AUGER CAST PILE ER DETAIL 1/S1.01. SEE PLAN FOR LOCATION 1'-6" 0 LI o BOT/PILE EL —16.50' .A.V.D. CRA E BEAM AT EDGE CONDITION STABILIZED SUBGRADE, NON—PLASTIC, INORGANIC, GRANULAR SOIL COMPACTED TO A DENSITY OF AT LEAST 95% MOF THE PROCTOR MAXIMUM DRY DENSITY (ASTM D 1537) SCALE: 3/4" = 1'-0" an WRAP PORTION OF POST EMBEDDED BELOW GRADE W/ SELF—ADHESIVE RUBBERIZED ASPHALTIC WATERPROOFING MEMBRANE z 1—#4x16" REBAR, --a THROUGH POST i 4, `2 SECTIO S1.01 SCALE: 3/ " = 1'-0" VERIFY RECESS SEE PLAN DIMS. WITH ARCH _ TOCP _O_F SLAB tc)G. 4" BREAK—AWAY SLAB 8» GARAGE SLAB AT OPENING SCALE: 314" = 1'-0" GARAGE SLAB W/ BREAK -AWAY WALL SCALE: 3/4" = 1'-0" LEV I• 7 c- m m a N LIG. Z p d o Z a� O W C'sell N O u� � w$ Ou-i o � �o < ti u..i C? 0 d c z U qy' O 01 own c- < Q 9 n � Sm U '• H 0 I• 7 m m N LIG. Z p d o Z O W z V O u� z z Ou-i d � w < z w u..i C? 0 d c z 1 V w to O z O Lu D cs� w Q 0 z O Lu cry ur 0 FOUNDATION DETAILS