1631 ATLANTIC BEACH DR - NEW HOME DRAWINGS1600 sil TL I ILY R Sl 0 C BEACH DR, ATLANTIC BEACH, SEE SURVEY FOR SITE INFORMATION 32233 IT ISS C 02, 2018 COVER SHEET A101 A102 A201 A301 A302 A303 A401 A402 A403 A501 A502 E101 E102 DRAWING INDEX ARCHITECTURAL SITE PLAN, VICINITY MAP, PROJECT INFORMATION & INDEX OF DRAWINGS FIRST FLOOR PLAN AND SCHEDULES SECOND FLOOR PLAN AND TYPICAL STAIRS DETAIL ROOF PLAN FRONT & RIGHT SIDE ELEVATIONS REAR & L:FFT SIDE ELEVATIONS PERSPECTIVE VIEWS TYPICAL WALL SECTIONS TYPICAL 4 )RCH COLUMN SECTION & TYPICAL DETAILS WALL SECTION @ PORCH WINDOW DETAILS @ CMU BLOCK WALL WINDOW, DOOR, & ROOF/ FLASHING DETAILS FIRST FLOOR ELECTRICAL SCHEMATIC PLAN SECOND FLOOR ELECTRICAL SCHEMATIC PLAN STRUCTURAL UNDER SEPARATE COVER PROJECT INFORMATION APPLICABLE CODES: FLORIDA BUILDING CODE 6th EDITION 2017 BUILDING FLORIDA BUILDING CODE 6th EDITION 2017 RESIDENTIAL CURRENT ATLANTIC BEACH LAND DEVELOPMENT CODE CONSTRUCTION TYPE: V OCCUPANCY CLASS: R-3 SEE SURVEY FOR ADDITIONAL INFORMATION HEIGHT: 35'-0" 29'-11" ACTUAL 50 SINGLE HUNG SINGLE HUNG SINGLE HUNG SINGLE HUNG SLIDING SINGLE HUNG WINDOW WINDOW WINDOW WINDOW WINDOW WINDOW O © © O O O WINDOW TYPES 1/411 = 1'-0" DOOR SCHEDULE Mark Width Height Count Comments 1 16' - 0" 8' - 0" 1 GARAGE DOOR 2 3' - 0" 8' - 0" 1 EXTERIOR DOOR 3 3'-0" 8'-0" 1 20 MIN. DOOR W/ CLOSURE 4 6'- 0" T- 111/2" 1 ENTRY DOOR W/ SIDELITES 5 14' - 0" T- 10 3/4" 1 PORCH SLIDING DOOR 6 6' - 2" 8' - 0" 1 PORCH FRENCH DOOR 7 3'-0" 8'-0" 2 8 3'-0" 8'-0" 1 9 2'-8" 8'-0" 2 10 2' - 8" 8' - 0" 1 POCKET DOOR 11 2'-6" 8'-0" 3 12 2'-4" 8'-0" 2 13 21-411 8' - 0" 3 POCKET DOOR 14 2'-0" 8'-0" 1 15 4' - 0" 8' - 0" 1 DOUBLE DOOR 16 3'-0" 8'-0" 1 17 10'-0" 9'-0" 3 18 3' - 0" 4' - 0" 1 GATE TO GARBAGE 19 5' - 0" 4' - 0" 1 GATE TO HVAC Grand total: 28 1 15'- 6" 48'- 0" 46'- 6" 15'-6" 15- 6'' M ---------------- 0 3r 3 9' . 0 CD CD? ev r o -8 8" 3: ' 0' .,p' 6' 4" p: 3' 'p 9 p 3, ' �,, .S„ _.p, • 1'4'- 0„ Qfe i = WALT : WALL k� MASTER BEDROOM I 7. - l o � I i 6'- 4" 3'- 10'' - 6" 4'- 8'' LIVING 'v I WALL SCONCE AH -1 IR~MI 22'- 0" 2 -CAR GARAGE co WALL SCONCE WALL SCONCE J GAS LANTERN ABOVE, SEE 1 /A301 PAVERS FINISH, SEE SITE PLAN A q0 3'-4" -0" 10'-8" 3'-0" 3'-4"-5"TYP. 23'- 4" 33'- 0" 57'-2" FIRST FLOOR PLAN 'J 1/411 = 1'-0" I AREA CALCULATION 1 st FLOOR ............. 2,299 sf 2nd FLOOR...............657 sf TOTAL COND......... 2,956 sf COVERED ENTR........ 176 SF GARAGE...................633 SF COV. PORCH ............ 480 SF TOTAL NON-COND..1,289 SF TOTAL UNDER ROOF ... 4,254 SF 120' LOT DEPTH, 70' WD 20' FT FRONT SETBACK 10' FT REAR SETBACK 5' FT SIDE SETBACK CV 0 (7 0 3 A401 4 A401 r r 121 Yellow Star Ln N Jacksonville, Florida 32224 904-716-6335 ©2018 Ogy Design, Inc. Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 FIRST FLOOR PLAN & SCHEDULES Project Number 2017.10.3 Drawn By ov Checked By ov A1 01 Scale 1/4 If= 1 1-011 I o ti 0 00 0 N co M STAIRS DETAIL 1" = 1'-0" 0 0 0) 4" / V-0" HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH, TYP. OR SECOND FLOOR PLAN 1/411 = 1'-0" 4" / V-0" 3 A401 4 A401 iii pEVE1.OpMEN1 COMMu� Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 SECOND FLOOR j PLAN ProjectNiinbef 2017.10.3 Date O1 -II -18 Drawn By OV Checked By OV A102_ Scale As indicated 7 co d- 0 r 00 r O N co co 1 A401 2 A401 REQUIRED ROOF VENTILATION CALCULATIONS TOTAL NET FREE VENTILATING AREA: 1/ 150 OF VENTILATED ATTIC SPACE ROOF VENTILATION BASIS OF DESIGN: "CORA-VENT" ROOF VENTILATION SYSTEMS, OR APPROVED EQUAL 1st FLOOR ROOF VENTILATION CALCULATIONS ABOVE GARAGE, KITCHEN, DINING: CALCULATION ATTIC AREA = 2,182 SF 2,182 SF: 150 = 14,6 SF 14,6 SF x 144 = 2,102 sq. in . PROVIDE 50% FOR INTAKE (ROOF EAVE VENTS) = 1,051 sq. in. PROVIDE 50% FOR EXHAUST (OFF -RIDGE VENTS)= 1,051 sq. in. ABOVE MASTER SUITE: CALCULATION ATTIC AREA = 821 SF 821 SF: 150 = 5,5 SF 5,5 SF x 144 = 792 sq. in . PROVIDE 50% FOR INTAKE (ROOF EAVE VENTS) = 396 sq. in. PROVIDE 50% FOR EXHAUST (OFF -RIDGE VENTS)= 396 sq. in. 2nd FLOOR ROOF VENTILATION CALCULATIONS CALCULATION ATTIC AREA = 657 SF 657 SF: 150 = 4.4 SF 4.4SFx144=634 sq. in. PROVIDE 50% FOR INTAKE (ROOF EAVE VENTS) = 317 sq. in. PROVIDE 50% FOR EXHAUST (RIDGE/ OFF -RIDGE VENTS)= 317 sq. in. INSTALL AL INTAKE/ EXHAUST VENTS PER MANUFACTURER'S RECOMMENDATION ROOF VENTILATION CALCS 111 = 1'-0„ / 1' /1 / 1' / 1' 0 /11-01, / 1' IDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM ;ULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR NPAINTED FINISH, TYP LS .: CD ROOF TRUSS BEARING - 1/411 = 1'-0" r No. Description Date : 011 �2 : � O I _ , i C? 5- 4' o f a� 411 / 1'-0 4" / V-0" 3 5 4,, k ....... ....... ............ o �r LO ROOF TRUSS BEARING - 1/411 = 1'-0" r No. Description Date : 011 3 A401 4 A401 r110\0 peawwwwo mwP:�_��z�olO�: e Yellow Star Ln N Jacksonville, Florida 32224 904-716-6335 ©2018 Ogy Design, Inc. Consultant Address Address Address Phone Consultant Address Address Address Phone ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 ROOF PLAN Project Number 20 17.1 0.3 Date 01-11-18 Drawn By Author Checked By Checker A201 Scale As indicated 7 d- 0 6 co 66 T_ O N M 1x2 TRIM OVER HEAD TRIM if 1x8 TRIM @ HEAD 1x4 TRIM @ JAMBS COLOR: WHITE 2x3 TRIM @ WINDOW SILL SLOPE TRIM 150 1x4 TRIM @ WINDOW SILL n WINDOW TRIM LEGEND @ SHAKE SIDING 1/211 = 1'-0" FRONT ELEVATION -J 1/4" = 1'-O" T.O. ROOF _ �7' - 11 1 /8" HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH \ PVC SINGLE HUNG WINDOW W/ TWO OVER TWO GRILLE PATTERN, WINDOWS MANUFACTURER: PGT \ FIBER CEMENT SHAKE SIDING - STRAIGHT EDGE COLOR: SW COLOR: SW 6455 CORNER TRIM, COLOR: SW 7006 EXTRA WHITE HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH 1'-0" RAISED PANEL EXTERIOR VINYL SHUTTERS, 16" WIDE COLOR: SW 7006 EXTRA WHITE - STUCCO FINISH, COLOR: SW 7006 EXTRA WHITE - 6" STUCCO WINDOW SILL @ FIRST FLOOR WINDOWS ONLY, COLOR: SW 7006 EXTRA WHITE - BRICK BASE W/ SOLDIER COURSE BAND, PAINT: SW 7006 EXTRA WHITE V-0" 9" lz7z FIBER CEMENT SHAKE SIDING - STRAIGHT EDGE COLOR: SW COLOR: SW 6455 FIBER CEMENT SHAKE SIDING - STRAIGHT EDGE COLOR: SW COLOR: SW 6455 CORNER TRIM, COLOR: SW 7006 EXTRA WHITE RIGHT SIDE ELEVATION `J 1/4" = T-0" c BRICK BASE W/ SOLDIER COURSE BAND, PAINT: SW 7006 EXTRA WHITE WALL SCONCE, SUSPENDED GAS MNF: HOME DECORATOR LANTERN, COLLECTION, TYP ALL ELEV'S MNF: PROGRESS LIGHTING GIBBES STREET COLLECTION 2 A401 1'-0" 91, A4 Eiffel 7' T.O. ROOF 27'- 11 1/8" DECORATIVE DORMER BEYOND HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH EXPOSED RAFTERS AT ENTARNCE P.T. 6x6 UPRIGHT, PAINT, CC)InR• RW Inn FXTRA WHITF FIBERGLASS ENTRY DOOR, 15"x15" BOXED OUT ENTRANCE GABLE BRICK BASE W/ SOLDIER COURSE BAND, MASONITE BELLEVILLE SMOOTH ROOF ACCENT FEATURE W/ P.T. 1x8 PAINT: SW 7006 EXTRA WHITE 2 PANEL HOLLISTER (BLS-122-SO6-1) CAP & P.T. 1x10 BASE, WITH 12" SIDELITES COLOR: SW 7006 EXTRA WHITE (BLS -SL -151-S03-1) 1 A401 3 A40 it HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH ROOF PLA 20'- 11 3/8" LU C ¢ 0 UJ O m U - 2nd FLOOR - T.O. o _ SHEATHING 11' - 10 11 /4"' 1 FLOOR TRUSS 10'- 1 1/2" FIRST FLOOR PLAN 0'-0" GRADE � -2' -- 0" 7 6" FASCIA AND FIBER- °, CEMENT SOFFIT, COLOR: SW 7006 EXTRA WHITE 12"x12" BOXED COLUMN W/ N P.T. 1 x8 CAP & P.T. 1 x10 BASE, COLOR: SW 7006 EXTRA WHITE CONCRETE STEPS BEYOND co _ ROOF PL28 N 20'- 11 3/8" LU ry (D LU O m ¢ u - 2nd FLOOR - T.O. o 0 SHEATHING 11' - 10 1 /4" 00 FLOOR TRUSS BEARING N 10' - 1 1 /2" FIRST FLOOR PLAN GRADE n -2' - 0" u COMMUNITY DEVELOPMENT APPROVED Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date j ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 j FRONT & RIGHT SIDE ELEVATIONS NumberProject 2017.10.3Date 1 O1 -I1-18 o`°'xn By Author Checked By - Checker A301 iScale As indicated oe n M N ti O O M r O N M M SEE WI OW/D R SCHEDULE 2x3 TRIM @ WINDOW SILL SLOPE TRIM 150 1x4 TRIM @ WINDOW SILL n WINDOW TRIM LEGEND @ SHAKE SIDING 1/211 = 1'-0" FRONT ELEVATION -J 1/4" = 1'-O" T.O. ROOF _ �7' - 11 1 /8" HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH \ PVC SINGLE HUNG WINDOW W/ TWO OVER TWO GRILLE PATTERN, WINDOWS MANUFACTURER: PGT \ FIBER CEMENT SHAKE SIDING - STRAIGHT EDGE COLOR: SW COLOR: SW 6455 CORNER TRIM, COLOR: SW 7006 EXTRA WHITE HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH 1'-0" RAISED PANEL EXTERIOR VINYL SHUTTERS, 16" WIDE COLOR: SW 7006 EXTRA WHITE - STUCCO FINISH, COLOR: SW 7006 EXTRA WHITE - 6" STUCCO WINDOW SILL @ FIRST FLOOR WINDOWS ONLY, COLOR: SW 7006 EXTRA WHITE - BRICK BASE W/ SOLDIER COURSE BAND, PAINT: SW 7006 EXTRA WHITE V-0" 9" lz7z FIBER CEMENT SHAKE SIDING - STRAIGHT EDGE COLOR: SW COLOR: SW 6455 FIBER CEMENT SHAKE SIDING - STRAIGHT EDGE COLOR: SW COLOR: SW 6455 CORNER TRIM, COLOR: SW 7006 EXTRA WHITE RIGHT SIDE ELEVATION `J 1/4" = T-0" c BRICK BASE W/ SOLDIER COURSE BAND, PAINT: SW 7006 EXTRA WHITE WALL SCONCE, SUSPENDED GAS MNF: HOME DECORATOR LANTERN, COLLECTION, TYP ALL ELEV'S MNF: PROGRESS LIGHTING GIBBES STREET COLLECTION 2 A401 1'-0" 91, A4 Eiffel 7' T.O. ROOF 27'- 11 1/8" DECORATIVE DORMER BEYOND HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH EXPOSED RAFTERS AT ENTARNCE P.T. 6x6 UPRIGHT, PAINT, CC)InR• RW Inn FXTRA WHITF FIBERGLASS ENTRY DOOR, 15"x15" BOXED OUT ENTRANCE GABLE BRICK BASE W/ SOLDIER COURSE BAND, MASONITE BELLEVILLE SMOOTH ROOF ACCENT FEATURE W/ P.T. 1x8 PAINT: SW 7006 EXTRA WHITE 2 PANEL HOLLISTER (BLS-122-SO6-1) CAP & P.T. 1x10 BASE, WITH 12" SIDELITES COLOR: SW 7006 EXTRA WHITE (BLS -SL -151-S03-1) 1 A401 3 A40 it HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH ROOF PLA 20'- 11 3/8" LU C ¢ 0 UJ O m U - 2nd FLOOR - T.O. o _ SHEATHING 11' - 10 11 /4"' 1 FLOOR TRUSS 10'- 1 1/2" FIRST FLOOR PLAN 0'-0" GRADE � -2' -- 0" 7 6" FASCIA AND FIBER- °, CEMENT SOFFIT, COLOR: SW 7006 EXTRA WHITE 12"x12" BOXED COLUMN W/ N P.T. 1 x8 CAP & P.T. 1 x10 BASE, COLOR: SW 7006 EXTRA WHITE CONCRETE STEPS BEYOND co _ ROOF PL28 N 20'- 11 3/8" LU ry (D LU O m ¢ u - 2nd FLOOR - T.O. o 0 SHEATHING 11' - 10 1 /4" 00 FLOOR TRUSS BEARING N 10' - 1 1 /2" FIRST FLOOR PLAN GRADE n -2' - 0" u COMMUNITY DEVELOPMENT APPROVED Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date j ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 j FRONT & RIGHT SIDE ELEVATIONS NumberProject 2017.10.3Date 1 O1 -I1-18 o`°'xn By Author Checked By - Checker A301 iScale As indicated oe n M N ti O O M r O N M M 1x2 TRIM OVER HEAD TRIM 1x8 TRIM @ HEAD 1x4 TRIM @ JAMBS COLOR: WHITE 2x3 TRIM @ WINDOW SILL SLOPE TRIM 150 1x4 TRIM @ WINDOW SILL WINDOW TRIM LEGEND Cad SHAKE SIDING FIBER CEMENT SHAKE SIDING - STRAIGHT EDGE COLOR: SW COLOR: SW 6455 CORNER TRIM, COLOR: SW 7006 EXTRA WHITE T.O. ROOF 27,- 11 1/8" ROOF PLAN 20' - 11 3/8" v REAR ELEVATION PVC SINGLE HUNG WINDOW W/ TWO OVER ONE GRILLE PATTERN, WINDOWS MANUFACTURER: PGT SEE WINDOW TRIM DIAGRAM FOR TRIM SIZES 911 HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH 2 LEFT SIDE ELEVATION A401 7 A401 3 A401 CONCRETE STEPS PVC FRENCH DOOR, MORTAR PARGE COAT, DOOR MANUFACTURER: PGT COLOR: BENJAMIN MOORE "WHITE DOVE", STUCCO FINISH, OR EQUAL SHERWIN WILLIAMS COLOR: SW 7006 EXTRA WHITE - HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH 1'-0" 01 co a T.O. ROOF 27'- 11 1/8" ROOF PLAN � 20'- 11 3/8" �7 LU n Q w O m Q 2nd FLOOR - T.O. o 0 _ SHEATHING b 11'- 10 1/4" ° 4.. 00 * FLOOR TRUSS BEARING 10' - 1 1 /2" N COLOR: SW 7006 EXTRA WHITE hIISCK GtMMI 31000U KUAKU GAIL HNSFI, YAINIW, COLOR: SW 7006 BRIGHT WHITE 10"x5/4" SMOOTH FIBER HIDDEN SCREW (STANDING SEAM) METAL SLIDING WINDOW W/ SILL STUCCO BAND CEMENT TRIM ROOFING SYSTEM, AND WITHOUT HEAD AND JAMB BANDS TRANSITION BOARD "GULF COAST" ROOFING, 5V CRIMP PANEL (TO MATCH SINGLE HUNG WINDOWS PROFILE, COLOR: UNPAINTED FINISH BANDS TREATMENT) COMMUNITY DEVELOPMENT APPROVED ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 -- it REAR & LEFT SIDE ELEVATIONS Project Number 2017.10.3 Date — 01-1 1-18 Drawn By — _. -Author. eGetl By Checker A302 Scale _ _ As indicated :. 7 Co M O 77 M 00 T- CD N M M LU 0 ryQ (D LU 0 m Q 2nd FLOOR - T.O. o 0 _ _SHEATHING 11 - 10 1 /4" Co 1 FLOOR TRUSS BEARING 10'- 1 1/2" REAR ELEVATION PVC SINGLE HUNG WINDOW W/ TWO OVER ONE GRILLE PATTERN, WINDOWS MANUFACTURER: PGT SEE WINDOW TRIM DIAGRAM FOR TRIM SIZES 911 HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH 2 LEFT SIDE ELEVATION A401 7 A401 3 A401 CONCRETE STEPS PVC FRENCH DOOR, MORTAR PARGE COAT, DOOR MANUFACTURER: PGT COLOR: BENJAMIN MOORE "WHITE DOVE", STUCCO FINISH, OR EQUAL SHERWIN WILLIAMS COLOR: SW 7006 EXTRA WHITE - HIDDEN SCREW (STANDING SEAM) METAL ROOFING SYSTEM, "GULF COAST" ROOFING, 5V CRIMP PANEL PROFILE, COLOR: UNPAINTED FINISH 1'-0" 01 co a T.O. ROOF 27'- 11 1/8" ROOF PLAN � 20'- 11 3/8" �7 LU n Q w O m Q 2nd FLOOR - T.O. o 0 _ SHEATHING b 11'- 10 1/4" ° 4.. 00 * FLOOR TRUSS BEARING 10' - 1 1 /2" N COLOR: SW 7006 EXTRA WHITE hIISCK GtMMI 31000U KUAKU GAIL HNSFI, YAINIW, COLOR: SW 7006 BRIGHT WHITE 10"x5/4" SMOOTH FIBER HIDDEN SCREW (STANDING SEAM) METAL SLIDING WINDOW W/ SILL STUCCO BAND CEMENT TRIM ROOFING SYSTEM, AND WITHOUT HEAD AND JAMB BANDS TRANSITION BOARD "GULF COAST" ROOFING, 5V CRIMP PANEL (TO MATCH SINGLE HUNG WINDOWS PROFILE, COLOR: UNPAINTED FINISH BANDS TREATMENT) COMMUNITY DEVELOPMENT APPROVED ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 -- it REAR & LEFT SIDE ELEVATIONS Project Number 2017.10.3 Date — 01-1 1-18 Drawn By — _. -Author. eGetl By Checker A302 Scale _ _ As indicated :. 7 Co M O 77 M 00 T- CD N M M 1 VIEW 1 0 VIEW 3 n VIEW 4 U Yellow Star Ln N Jacksonville, Florida 32224 904-716-6335 ©2018 Ogy Design, Inc. Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date FI ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT b PERSPECTIVE VIEWS Project ""'"oe` 2077.10.31 Date 01-11-1 Drawn By _. Author Checked By Checker ScaleA303 7 N O M r 00 0 N co co 6 MILL VAPOR TERMITE TREATED SOIL CONC. FOUNDATION, SEE STRUCTURAL ,gk ELEV: 10'-1 1/2" TRUSS BEARING I - — — — —1 ELEV: 10'-0" ---- T.O.CMU— HALF-ROUND ALUM. - @ 2ND FL. SIDING 1 SINGLE HUNG WINDOW, SEE SCHEDULE @ 2ND FL. SIDING @ 2ND FL. SIDING A501 A502 J6" SILL STUCCO BAND $' STUCCO SYSTEM ON CMU BLOCK WALL ELEV: 0'-0" CMU STEM WALL, SEE FIRST FLOOR STRUCTURAL SEE ELEVATIONS FOR o BRICK VENEER N LOCATIONS GRADE 1 -STORY EXTERIOR WALL SECTION 3/4"=1'-0" 12 \ 9 2' GWB ON WOOD ROOF TRUSSES R-9 CMU CORE -FILL WALL INSULATION APPLICATION R-5 RIGID WALL INSULATION 2' GWB ON P.T. 2x4 FURRING @ 24" O.C. SEE ROOF PLAN 12 4 _K EEL -V: 10'-1 1/2" _ TR SS BEARING I - — — J EL V: 10'-0" ---- -------- T. .CMU 7-0" HALF -ROUND ALUM. GUTT R 8" CMU BLOCK WALL " STUCCO SYSTEM ON CMU SURFACE WATER REPELLANT APPLICATION ZI 2 A402 CONC. SLAB / ----------a-----------------rr�'fT�7- r7f�T%�rJ i CMU STEM WALL, SEE STRfICTURAL 6 MILL VAPOR // MO TAR PARGE COAT BARRIER ON \/\a COMPACTED AND \\/\\\ GRADE TERMITE TREATED SOIL CONC. FOUNDATION, SEE STRUCTURAL ° ` \/X ° 1 -STORY EXTERIOR WALL SECTION 3/4"=1'-0" PRE-ENGINEERED ROOF WOOD TRUSSES 12 SELF -ADHERED ROOFING UNDERLAYMENT 9 METAL ROOF PANEL SYSTEM OVER SELF -ADHERED UNDERLAYMENT OVER ROOF SHEATHING OVER PRE -ENG. WOOD ROOF TRUSSES 3'-4" 2'-0" k 1 g a s ELEV: 20'-1 1 3/8" -v - TRUSS BEARING R-38 ROOF ------ INSULATION HALF -ROUND 2' GWB ON PRE -ENG. ALUM. GUTTER IWOOD ROOF TRUSSES VENTED PVC SOFFIT 4" x 3 -2 FIBER -CEMENT SMOOTH TRIM A402 T&G PLYWOOD SUBFLOORING , REFER TO STRUCTURAL ---------------- 'GWB ON WOOD R-9 CMU CORE -FILL WALL INSULATION APPLICATION R-5 RIGID WALL INSULATION 2' GWB ON P.T. 2x4 11R'WIZ[eZcvz'KOXN FIBER -CEMENT SIDING OVER WATER RESISTIVE BARRIER, PROVIDE SEALANT AT ALL EXTERIOR JOINTS PER MFR SPECIFICATION WALL SHEATHING, REFER TO STRUCTURAL 2x4 EXTERIOR WALL FRAMING, REFER TO STRUCTURAL R-13 WALL INSULATION "Z" FLASHING PER MANUF. STANDARD s 8" CMU BLOCK WALL 8' STUCCO SYSTEM ON CMU BLOCK WALL CMU SURFACE WATER REPELLANT APPLICATION 2 A402 CONC. SLAB EL V:0'-0" _ FI ST FLOOR •° e °.. a — ---- — — — — — -----------------------=-----7T,-7/-,7 T�'l�'�l�i CMU STEM WALL, SEE \ \\\ STR rV CTURAL CD MO TAR PARGE COAT 6 MILL VAPOR BARRIER ON COMPACTED AND /�\\\\\\� GRADE TERMITE TREATED SOIL CONIC. FOUNDATION, \ SEE STRUCTURAL \/ 2 -STORY EXTERIOR WALL SECTION 3/4"=1'-0" ELEV: 0'-0" FIRST FLOOR 6 MILL VAPOR BARRIER ON COMPACTED AND TERMITE TREATED SOIL CONC. FOUNDATION SEE STRUCTURAL PRE-ENGINEERED ROOF WOOD TRUSSES SELF -ADHERED ROOFING UNDERLAYMENT >k** METAL ROOF PANEL SYSTEM OVER /SELF -ADHERED UNDERLAYMENT OVER ROOF SHEATHING OVER PRE -ENG. WOOD ROOF TRUSSES _ _ _ ot ELEV: 20'-11 3/8" TRUSS BEARING ALUM. GUTTER VENTED PVC SOFFIT FIBER-CEMEN I 4" CORNER TRIM BEYOND I I\V YI✓L JOINTS PER MFR SPECIFICATION WALL SHEATHING, REFER TO STRUCTURAL 2x4 EXTERIOR WALL FRAMING, REFER TO STRUCTURAL "Z" FLASHING PER 4" x 10" FIBER -CEMENT SMOOTH TRIM, T.O. BAND AT FLOOR LINE _ _ _ _ oL ELEV: 1 Y-9 7/8" METAL FLASHING SECOND FLOOR T.O. SHEATHING 12 4 h ELEV: 10'-1 1/2" TRUSS BEARING I — —_ _ _ _ _ — ELEV: 10'-0" T.O.CMU 8" CMU BLOCK WALL STUCCO SYSTEM ON CMU SURFACE WATER REPELLANT APPLICATION ELEV: 0'-0" FIRST F OOR CMU STEM WALL, SEE STRUCTURAL MORTAR PARGE COAT q 2 -STORY EXTERIOR WALL SECTION 3/4"=1'-0" Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 TYPICAL WALL SECTIONS Project Number 201 7.10.3 date 03-02-18 Drawn By Author Checked By Checker A 01 Scale ELEV: 1 1'-9 7/8" _ SECOND FLOOR 4" x 10" FIBER -CEMENT T.O. SHEATHING SMOOTH TRIM, T.O. BAND AT FLOOR LINE 8' STUCCO SYSTEM h ELEV: 10'-1 1/2" ABOVE CONTROL TRUSS BEARING I JOINT -- -- — — — — — — — — —— ELEV: 10'-0"OL -- ---— `r T.O.CMU STUCCO CONTROL JOINT @ 10'-1 2" ELEVATION 8" CMU BLOCK WALL 8' STUCCO SYSTEM ON CMU BLOCK WALL CMU SURFACE WATER REPELLANT APPLICATION 2 A402 CONC. SLAB EL V:0'-0" _ FI ST FLOOR •° e °.. a — ---- — — — — — -----------------------=-----7T,-7/-,7 T�'l�'�l�i CMU STEM WALL, SEE \ \\\ STR rV CTURAL CD MO TAR PARGE COAT 6 MILL VAPOR BARRIER ON COMPACTED AND /�\\\\\\� GRADE TERMITE TREATED SOIL CONIC. FOUNDATION, \ SEE STRUCTURAL \/ 2 -STORY EXTERIOR WALL SECTION 3/4"=1'-0" ELEV: 0'-0" FIRST FLOOR 6 MILL VAPOR BARRIER ON COMPACTED AND TERMITE TREATED SOIL CONC. FOUNDATION SEE STRUCTURAL PRE-ENGINEERED ROOF WOOD TRUSSES SELF -ADHERED ROOFING UNDERLAYMENT >k** METAL ROOF PANEL SYSTEM OVER /SELF -ADHERED UNDERLAYMENT OVER ROOF SHEATHING OVER PRE -ENG. WOOD ROOF TRUSSES _ _ _ ot ELEV: 20'-11 3/8" TRUSS BEARING ALUM. GUTTER VENTED PVC SOFFIT FIBER-CEMEN I 4" CORNER TRIM BEYOND I I\V YI✓L JOINTS PER MFR SPECIFICATION WALL SHEATHING, REFER TO STRUCTURAL 2x4 EXTERIOR WALL FRAMING, REFER TO STRUCTURAL "Z" FLASHING PER 4" x 10" FIBER -CEMENT SMOOTH TRIM, T.O. BAND AT FLOOR LINE _ _ _ _ oL ELEV: 1 Y-9 7/8" METAL FLASHING SECOND FLOOR T.O. SHEATHING 12 4 h ELEV: 10'-1 1/2" TRUSS BEARING I — —_ _ _ _ _ — ELEV: 10'-0" T.O.CMU 8" CMU BLOCK WALL STUCCO SYSTEM ON CMU SURFACE WATER REPELLANT APPLICATION ELEV: 0'-0" FIRST F OOR CMU STEM WALL, SEE STRUCTURAL MORTAR PARGE COAT q 2 -STORY EXTERIOR WALL SECTION 3/4"=1'-0" Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 TYPICAL WALL SECTIONS Project Number 201 7.10.3 date 03-02-18 Drawn By Author Checked By Checker A 01 Scale METAL ROOF PANEL SYSTEM OVER SELF -ADHERED ROOFING UNDERLAYMENT OVER ROOF SHEATHING OVER PRE -ENG. WOOD ROOF TRUSSES SELF -ADHERED ROOFING UNDERLAYMENT ROOF SHEATHING, REFER TO STRUCTURAL PRE -ENG. WOOD ROOF TRUSSES, REFER TO STRUCTURAL 12 �4 BEAM/ POST CENTERLINE 2'-3" HURRICANE CLIP, REFER TO STRUCTURAL FIBER -CEMENT PANEL SOFFIT 2x4 BLOCKING @ 24" O.C. W4" FIBER -CEMENT TRIM FIBER -CEMENT PANEL WRAP ON 2x FRAMING I 0 0 WOOD BEAM, REFER TO STRUCTURAL v BEAM TO POST CONNECTOR, + VENTED FIBER -CEMENT SOFFIT REFER TO STRUCTURAL FIBER -CEMENT PANEL WRAP �N ON 2x FRAMING 1" I 2.: TRIM NOTE: ALL TRIM CORNERS TO BE MITER CUT/ MITER JOINTS FIBER -CEMENT PANEL WRAP co ON 2x FRAMING 2' N31 TRIM I 2'-0" P.T. POST, REFER TO STRUCTURAL 1 0 3-0" COLUMN FIBER -CEMENT PANEL WRAP �-- FACE OF PORCH SLAB I I EAVE/ COLUMN CAPITAL DETAIL 1-1 /2"=V-0" NOTE TO CONTRACTOR: DO NOT STOP DECORATIVE COLUMN BASE AT PROJECTED LINE OF THE FLOOR LEVEL. BASE TRIM TO BE INSTALLED AS SHOWN W/-" GAP ABOVE CONC. SLAB 1' P.T. POST, REFER TO STRUCTURAL DECORATIVE COLUMN FIBER 4: POST BASE ANCHOR & a 3l: 4 CONC. PEDESTAL, REFER TO STRUCTURAL ° STOP BASE 2' AT SLAB AND SEAL ALL AROUNDa :° ° ° .. .. c Qc ° d �4 M ° d a --------------- —1— — —Y— — --C— 77 — \/\\/ /\ t,71 7 NAA Al COLUMN/ POST BASE DETAIL 1 1/2"=V-0" 10" COLUMN BASE FIBER -CEMENT TRIM OIL ELEV: 0'-0" FIRST FLOOR o,L ELEV: 10'-1 1/2" BEAM PLATE HEIGHT METAL PANEL CLOSURE PER MANUFACTURER'S STANDAR ALUMINUM DRIP WHITE FLASHING OVER P.T. 1x2 DRIP OVER P.T. 2x6 FASCIA, PAINT FASCIA SW 7006 EXTRA WHITE ROOF TRUSS a a ^° METAL ROOF PANEL SYSTEM OVER SELF -ADHERED ROOFING UNDERLAYMENT OVER ROOF SHEATHING OVER PRE -ENG. WOOD ROOF TRUSSES SELF -ADHERED ROOFING UNDERLAYMENT ROOF SHEATHING, REFER TO STRUCTURAL PRE -ENG. WOOD ROOF TRUSSES, REFER TO STRUCTURAL INSULATION BAFFLE BETWEEN ALL TRUSSES HURRICANE CLIP, REFER TO STRUCTURAL 12 \ F � 4 '" GWB R-38 ROOF 2' GWB 2x4 WALL FRAMING, REFER TO STRUCTURAL R-13 WALL INSULATION EAV E DETAIL 1 1/2"=V-0" R-9 CMU CORE -FILL WALL_ INSULATION APPLICATION R-5 RIGID WALL INSULATION 2' GWB ON x4 FURRING CONC. SLA 2x4 BLOCKING @ 24" O.C. METAL PANEL CLOSURE PER MANUFACTURER'S STANDAR VENTED PVC SOFFIT 4' x 3 2' FIBER -CEMENT SMOOTH TRIM FIBER -CEMENT SIDING OVER WATER RESISTIVE BARRIER 4' STUCCO SYSTEM MORTAR PARGE COAT d ° 4 d d T\/\ 77/ \7\� d MORTAR PARGE COAT \ \\ \\ a CMU STEM WALL, REFER TO STRUCTURAL CONC, FOOTING, REFER TO STRUCTURAL GRADE \ ° d d a ° a 2 WALL BASE DETAIL 11/2-1 0 ALUMINUM DRIP WHITE FLASHING ROOF TRUSS PLUMB CUT STYLE METAL ROOF PANEL SYSTEM OVER - HIDDEN SCREW (STANDING SEAM) SELF -ADHERED ROOFING UNDERLAYMENT METAL ROOFING SYSTEM, OVER ROOF SHEATHING OVER PRE -ENG. "GULF COAST" ROOFING, 5V CRIMP WOOD ROOF TRUSSES PANEL PROFILE, COLOR: UNPAINTED 12 BEAM/ FINISH, TYP. 4 POST CENTERLINE 1 _ OIL ELEV: 10'-1 1/2" I IT.O. BEAM/ PLATE HEIGHT i FACE OF SLAB/ CMU STEM WALL P.T. POST, REFER TO STRUCTURAL I I I 12"x12" FINISHED I DECORATIVE COLUMN SHAFT W/ FIBER -CEMENT PANEL WRAP I LINE OF PORCH SLAB CMU STEM WALL FACE I I I 4 � I I A402 t� 9" CONC.PEDESTAL, REFER TO CONC. SLAB, REFER I STRUCTURAL TO STRUCTURAL ELEV: 0'-0" 107 SLOPE FIRST FLOOR 1 1/2"=V-01" 1100 Son NO 001000�sooz� . ..... nor Nk", Yellow Star Ln N Jacksonville, Florida 32224 904-716-6335 ©2018 Ogy Design, Inc. Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 TYPICAL WALL SECTIONS Project Number 2017.10.3 Date 03-02-18 Drawn By Author Checked By Checker A 02 Scale 66 N r co T 0 N N co CONC. FOOTING, REFER TO STRUCTURAL BEAM/ POST i .•° CENTERLINE a / ,\ SECTION @ PORCH COLUMN/ EAVE 1 1/2"=V-01" 1100 Son NO 001000�sooz� . ..... nor Nk", Yellow Star Ln N Jacksonville, Florida 32224 904-716-6335 ©2018 Ogy Design, Inc. Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 TYPICAL WALL SECTIONS Project Number 2017.10.3 Date 03-02-18 Drawn By Author Checked By Checker A 02 Scale 66 N r co T 0 N N co STEP 2: INSTALL AND SECURE BUCK AS REQUIRED STEP 1 A: APPLY LIQUI7n— MEMBRANE WATERPROO (WATER REPELLANT) OVER CMU OPENING JAMB FACE PRIOR TO P.T. 1x6 OR 2x6 BUCK INSTALLATION STEP 3: APPLY LIQUID i WATERPROOFING o MEMBRANE OVER i BUCK AND TURN MIN. 6' 1 i i i STEP 4: APPLY CMU WATER REPELLANT ! SILL BAND BELLOW STEP 3:I CLOSED CELL BAKER APPLY LIQUID WATERPROOFING ROD MEMBRANE OVER P.T. BUCK COORDINATE WITH WINDOW COMPATIBLE SEALAP MANUFACTURER/ SUPPLIER FOR P.T. 1x6 OR P.T. 2x6 BUCK USE I STUCCO RETURN STUCCO CORNER BEAD STUCCO CASING BEAD STEP 1 B: APPLY LIQUID4" PLYWOOD STRIP WATERPROOFING ATTACHED TO CM MEMBRANE 4" OVER CMU EXTERIOR FACE JAMB FLASHING —J AMB FLASHING @ CMU BOCK WALL 4 3' =1'-0" STEP 4: APPLY CMU WAT REPELLANT IN STEP 3: APPLY LIQUID WATERPROOFING MEMBRANE OVER ° ---- BUCK AND TURN a a d STEP 1 A: Q d d WATERPROOFING MEMBRANE (WATER STEP 2: REPELLANT) OVER CMU INSTALL AND SECURE OPENING HEAD FACE BUCK AS REQUIRED O 2x6 BUCK INSTALLATION a a d d a a Q d a d d a a d •d a a d d MEMBRANE OVER ---- BUCK AND TURN UP MIN. 6" STEP 1 A: APPLY LIQUID WATERPROOFING MEMBRANE (WATER STEP 2: REPELLANT) OVER CMU INSTALL AND SECURE OPENING HEAD FACE BUCK AS REQUIRED PRIOR TO P.T. 1x6 OR 2x6 BUCK INSTALLATION STEP 1 B: APPLY LIQUID WATERPROOFING MEMBRANE 4" OVER CMU EXTERIOR FACE COORDINATE WITH WINDOW MANUFACTURER/ SUPPLIER FOR P.T. lx6 OR P.T. 2x6 BUCK USE STEP 3: APPLY LIQUID WATERPROOFING MEMBRANE OVER P.T. BUCK HEAD FLASHING @ CMU BLOCK WALL 5 W=1'-0" 8' STUCCO SYSTEM OVER WATER RLPELLANT OVER CMU BLOCK WALL JAMB DETAIL @ CMU BLOCK WALL W=1'-0" 8' STUCCO SYSTEM OVER WATER REPELLANT OVER CMU BLOCK WALL HEADER FLASHING CLOSED CELL BAKER ROD 4" PLYWOOD STRIP ATTACHED TO CMU STUCCO BEAD BY "VINYL CORP." 1/2" DRIP SCREED REVEAL STUCCO RETURN COMPATIBLE SEALANT WALL EDGE BEYOND HEAD DETAIL @ CMU BLOCK WALL 3"=1'-0" SILL BELOW WINDOW SYSTEM CONTINUOUS SEALANT GWB TURN P.T. 2x6 BLOCKING SEE DETAIL 4 OF THIS SHEET FOR FLASHING STEPS 2' GWB ON P.T. 2x FURRING R-13 WALL INSULATION 8" CMU BLOCK WALL 8" CMU BLOCK WALL R-13 WALL INSULATION 2' GWB ON P.T. 2x FURRING GWB TURN CONTINUOUS SEALANT WINDOW SYSTEM CLOSED CELL SPRAY FOAM SEALANT AT WINDOW FRAME AND ROUGH OPENING/ BUCK JUNCTURE PERIMETER SEALANT STUCCO BAND WITH SLOPED TOP M STUCCO FINISH OVER WATER REPELLANT OVER CMU BLOCK WALL SILL DETAIL @ CMU BLOCK WALL 3"=1'-0" 6"=1'-0" CONTINUOUS SEALANT P.T. 2x6 BLOCKING (BUC MARBLE SILL SEE DETAIL 4 OF THIS SHEET FOR FLASHING STEPS Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 WINDOW DETAILS @ CMU BLOCK WALL Project Number 2017.10.3 Date 03-02-18 Drawn By Author Checked By Checker A501 Scale ao 77N T— oo oo T— CD N N co I I I I I I I SELF -ADHERED MEMBRANE FLASHING UNDER SILL PAN FLASHING, TURN MEMBRANE FLASHING 8" UP AT JAMBS FLOORING AS SCHEDULED I � I IOIrLT10 � L...... ... SET THRESHOLD OVER DOOR SILL PAN FLASHING OVER SELF -ADHERED MEMBRANE FLASHING, ANCHOR THRESHOLD ACCORDING TO MANUF. RECOMMENDATION & STANDARD DOOR SLOPED SILL PAN FLASHING WITH WEEPS & END DAMPS 4 : 1x4 FIBER CEMENT TRIM EXPANSION MATERIAL \\ 4 �, ■ \ CONC. SLAB. SEE STRUCTURAL i\\d DOOR THRESHOLD DETAIL, TYP. SELF -ADHERED MEMBRANE FLASHING UNDER SILL PAN FLASHING, TURN MEMBRANE FLASHING 8" UP AT JAMBS n DOOR, SEE SCHEDULE SET THRESHOLD OVER DOOR SILL PAN FLASHING OVER SELF -ADHERED MEMBRANE FLASHING, ANCHOR THRESHOLD ACCORDING TO MANUF. RECOMMENDATION & STANDARD 1/ DOOR SLOPED SILL PAN FLASHING WITH WEEPS & END DAMPS I I I \\ 4 L A NOM. 2x SLAB RECESS, I ' CONC. SLAB, SEE STRUCTURAL COORD. W/ DOOR TYPE ; i\\ d / a Q d d /\/\ THRESHOLD DETAIL @ SLIDING LANAI DOOR, TYP. 3"=1'-0" FIBER CEMENT SIDING OR STUCCO SYSTEM WATER RESISTIVE BARRIER TURN ROOF MEMBRANE UP MIN. 8" AS SHOWN o I I I I I z I WATER RESISTIVE BARRIER I I II o V~ 00 Z co "J" CLOSURE L.' J FIBER CEMENT SIDING OR W I (WRB) Z METAL ROOFING PANEL SYSTEM J U- II FASTENER @ 18" O.C. MAX, SEAL " WINDOW FRAME AND INSULATION z_ / m STARTER STRIP PER MANUF. I STANDARDS MAINTAIN MIN. 2" OVERLAP SILL FLASHING. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. LU , 1 FIBER CEMENT SIDING -ALUMINUM FLASHING & "Z" CLOSURE II FIBER CEMENT SIDING PERIMETER cv II I z FASTENERS PER I `' CAULK STANDARpTURER'S 10 I� FIBER CEMENT SIDING OR STUCCO SYSTEM WATER RESISTIVE BARRIER TURN ROOF MEMBRANE UP MIN. 8" AS SHOWN WINDOW HE D DETAIL WINDOW H�ED DETAIL 3"=1'-0" o V �, I WATER RESISTIVE BARRIER STARTER STRIP PER MANUF. STANDARDS o V~ 00 Z WATER RESISTIVE BARRIER "J" CLOSURE N Or FIBER CEMENT SIDING OR D m I (WRB) A METAL ROOFING PANEL SYSTEM JAMB FLASHING FASTENER @ 18" O.C. MAX, SEAL " WINDOW FRAME AND INSULATION EXTEND JAMB FLASHING TO / 3/4" TURN -UP STARTER STRIP PER MANUF. I STANDARDS MAINTAIN MIN. 2" OVERLAP SILL FLASHING. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. , 1 FIBER CEMENT SIDING -ALUMINUM FLASHING & "Z" CLOSURE O 1' �I FIBER CEMENT SIDING PERIMETER 1 I JUNCTURE\��� FASTENERS PER I `' CAULK STANDARpTURER'S PLUMB, AND LEVEL CONDITION. USE CORROSION �\ RESISTANT FASTENERS. FASTEN WI /II W DOW MANUFACTURER PEGIFICANTDIONS.R \ I WEATHER RESISTANT MARBLE SILL BARRIER -WRB / I 2x3 SLOPED FIBER CEMENT 2' GWB OVER 2x "." I RESISTIVE BARRIER WRIB ESAABNOVE. yWATER SILL TRIM::..�,._r° WALL FRAMING fNTERIOR VIEW .. TOP LEFT CORNER OF WINDOW SELF -ADHERED FLASING 1 SELF -ADHERED FLASING 1 OVER "Z" FLASHING t �, OVER "Z" FLASHING I I -. -- 1 I j i CONT. SEALANT CAULK �� I. STARTING STRIP 4' x +/- 3 2' i. VENTED SOFFIT 71 I■ FIBER -CEMENT CONT. CAULK — IC 4' GAP - DO NOT CAULK SMOOTH TRIM " ...._..._..- 1 x 4 FIBER CEMENT TRIM SILL FLASHING, \,................... I■ 1 BETWEEN SIDING & I . .•.;`` I - 4' GAP DO NOT CAULK .. I' ' '4 FLASHING .._... h THIS SHEET BETWEEN SI DING & R-13 WALL ` 1 ' R-13 WALL I I FLASHING INSULATION,;;"'.~ I METAL "Z" FLASHING W/ INSULATION JAMB FLASHING, SEE 1x4 WINDOW ,.......••-""' I� 1x4 FIBER CEMENT TRIM 1 MIN. 2 -' VERT. LONG LEG 2 DETAIL 1 OF THIS SHEET - " \ I METAL "Z" FLASHING W/ �� 1 AND-! LEG OVER 2x2 MIN. 22' VERT. LONG LEG TRIM I AND �" LEG OVER 2x2 2 2' GWB OVER 2x I 1 �" GWB OVER 2x z " . ; ..," y 1 I TRIM WALL FRAMING �......-.-' 2' GWB OVER 2x I I 2x2 FIBER CEMENT TRIM WALL FRAMING I '' 1 " �.,, .,..• "" GWB CORNER CLOSED CELL BAKER WALL FRAMING _` 1 1 =��'< �* I I •` ��� `��,,b �' I 2x2 FIBERCEMENT TRIM ROD & SEALANT `\ I WRB OVER HEAD "-"'����\ 1 R-13 WALL \. I FLASHING PERIMETER CAULK " z I WRB OVER HEAD I 1-" 1x8 FIBER CEMENT TRIM CLOSED CELL SPRAY 1 FLASHING \ \ �I \ ` ; 1 1 x8 FIBER CEMENT TRIM lxb WINDOW TRIM I 1x6 WINDOW TRIM FOAM SEALANT AT ■I WINDOW FRAME AND �, I ROUGH OPENING ": - ■I■I i ff__��HEAD FLASHING, SEE :I HEAD FLASHING, SEE ' ■' DETAIL 1 OF THIS SHEET ... ■' DETAIL 1 OF THIS SHEET GWB CORNER CLOSED CELL BAKER GWB CORNER CLOSED CELL BAKER BEAD, TYP. ROD &SEALANT BEAD, TYP. ROD &SEALANT PERIMETER CAULK PERIMETER CAULK CLOSED CELL SPRAY CLOSED CELL SPRAY SHIM AS REQUIRED FOAM SEALANT AT SHIM AS REQUIRED FOAM SEALANT AT WINDOW FRAME AND WINDOW FRAME AND ROUGH OPENING ROUGH OPENING JUNCTURE JUNCTURE WINDOW HE D DETAIL WINDOW H�ED DETAIL 3"=1'-0" FASTENER @ 18" O.C. MAX, SEAL o ALL PENETRATIONS UJ , 3"=1'-0" CLOSED CELL SPRAY STARTER STRIP PER MANUF. STANDARDS o MAINTAIN MIN. 2" GAP TO ROOF SURFACE 00 Z WINDOW "J" CLOSURE N Or FIBER CEMENT SIDING OR D m FOAM SEALANT AT R-13 WALL A METAL ROOFING PANEL SYSTEM JAMB FLASHING FASTENER @ 18" O.C. MAX, SEAL ALL PENETRATIONS WINDOW FRAME AND INSULATION EXTEND JAMB FLASHING TO / 3/4" TURN -UP STARTER STRIP PER MANUF. I STANDARDS MAINTAIN MIN. 2" OVERLAP SILL FLASHING. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. ROUGH OPENING I METAL ROOFING -ALUMINUM FLASHING & "Z" CLOSURE O 1' �I FIBER CEMENT SIDING PERIMETER I JUNCTURE\��� FASTENERS PER I `' CAULK STANDARpTURER'S PLUMB, AND LEVEL CONDITION. USE CORROSION �\ RESISTANT FASTENERS. FASTEN WI /II W DOW MANUFACTURER PEGIFICANTDIONS.R I WEATHER RESISTANT MARBLE SILL BARRIER -WRB / AT A 4B DEGREE ANGLE, CAREFULLY CUT THE 2x3 SLOPED FIBER CEMENT 2' GWB OVER 2x "." I RESISTIVE BARRIER WRIB ESAABNOVE. yWATER SILL TRIM::..�,._r° WALL FRAMING fNTERIOR VIEW TOP LEFT CORNER OF WINDOW 1 t I -. -- j i CONT. SEALANT CAULK �� 71 I■ 15.00° CONT. CAULK — IC " ...._..._..- 1 x 4 FIBER CEMENT TRIM SILL FLASHING, " z I■ SEE DETAIL 1 OF I' 1x4 WINDOW TRIM I� THIS SHEET CONT. SEALANT �,, "."�`` 1■ JAMB FLASHING, SEE 1x4 WINDOW ,.......••-""' I� 1x4 FIBER CEMENT TRIM I: z DETAIL 1 OF THIS SHEET TRIM I''77 �� 1 CAULK ------ CONT. SEALANT 2' GWB OVER 2x y I '' 1 " FIBER CEMENT SIDING GWB CORNER CLOSED CELL BAKER WALL FRAMING =��'< �* I I BEAD, TYP. ROD & SEALANT R-13 WALL i WATER RESISTIVE BARRIER PERIMETER CAULK INSULATION I (WRB) CLOSED CELL SPRAY \ SHIM AS REQUIRED I FOAM SEALANT AT WINDOW FRAME AND �, I ROUGH OPENING JUNCTURE FASTENER @ 18" O.C. MAX, SEAL o ALL PENETRATIONS UJ , 3"=1'-0" STARTER STRIP PER MANUF. STANDARDS o MAINTAIN MIN. 2" GAP TO ROOF SURFACE 00 Z J "J" CLOSURE N Or FIBER CEMENT SIDING OR D m FIELD -FORMED PANEL LEG Z w A METAL ROOFING PANEL SYSTEM WINDOW SILL DETAIL 4 3"=1'-0" WATER RESISTIVE BARRIER, EXTEN OVER ALUM. HEADWALL FLASHING FIBER CEMENT SIDING OR STUCCO SYSTEM OVER WATER A RESISTIVE BARRIER JAMB FLASHING FASTENER @ 18" O.C. MAX, SEAL ALL PENETRATIONS EXTEND JAMB FLASHING TO / 3/4" TURN -UP STARTER STRIP PER MANUF. I STANDARDS MAINTAIN MIN. 2" OVERLAP SILL FLASHING. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. GAP TO ROOF SURFACE I METAL ROOFING -ALUMINUM FLASHING & "Z" CLOSURE O 1' �I PANEL SYSTEM PER MANUFACTURER'S STANDAR — METAL ROOFING PANEL SYSTE FASTENERS PER SILL FLASHING i STANDARpTURER'S PLUMB, AND LEVEL CONDITION. USE CORROSION �\ 3/4" TURN -UP CONT. SELF -ADHERED SEALANT MEMBRANE CONT. "J" CLOSURE ROOF SHEATHING SEALANT PROVIDE FLASHING PER FASTENERS PER FBC R903.2.1 SELF -ADHERED SIDEWALL MANUFACTURER'S MEMBRANE STANDARD ROOF SHEATHING ROOF FLASHING DETAIL @ SIDEWAL.L HEAD WALL FLASHING DETAIL 3"=1'-0" WINDOW JAMB DETAIL 3"=1'-0" RIDGE VENT CAP PER HIP/RIDGE FLASHING W/ "Z" MANUFACTURER'S STANDARD CLOSURES SEALANT (AT VERTICAL LEG & UNDER "Z") 3/4" TURN -UP SELF -ADHERED MEMBRANE FASTENERS PER ROOF SHEATHING MANUFACTURER'SLl STANDARD ROOF FRAMING NON -VENTED HIP/ RIDGE HIP/ RIDGE DETAIL WOOD FRAME CONSTRUCTION CODE COMPLIANT WINDOW IN5TALLATiON METHOD (F15C-8-033) WEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION. FLASHING APPLIED QdERR THE FACE OF THE MOUNTING FLANGE. STEPS (DIN WATER SHEDDING= FASHION, STARTING AT THE BASE OF THE WALL t WORKING TOWARDS'',. THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING. Q APPLY BILL FLASHING (4or(o") O APPLY BEAD OF SEALANT AT BACK OF WINDOW FLANGE TO HEAD 4 BOTH JAMBS. APPLY A DISCONTINUOUS BEAD TO BOTTOM FLANGE LEAVING ®SET WINDOW USING PAN HEAD SCREWS TO FACILITATE INSPECTION, O APPLY JAMB FLASHING © APPLY BEAD OF SEALANT AT HEAD © APPLY HEAD FLASHING ® REMOVE PREVIOUSLY APPLIED TAPE, ALLOWING WRB TO LAY FLAT OVER HEAD FLASHING. APPLY NEW SHEATHING TAPE OVER DIAGONAL CUT - SEE DIAGRAM. © SEALANT BEAD BEHIND MOUNTING FLANGE, SEAL THE WINDOW FRAME TO OPENING. APPLY A V NOM. DIA. TO THE BACKSIDE (INTERIOR) OF THE WINDOW FLANGE, IN LINE WITH ANY PRE -PUNCHED HOLES OR SLOTS. (5 JAMB FLASHING APPLY CONT. SEAL TO THE MOUNTING FLANGES AT THE TOP (HEAD) AND BIDES (JAMBS) OF WINDOW. EMBED JAMB FLASHING INTO SEALANT AND FASTEN IN PLACE. (FLASHING GOES OVER SEALANT). in SECTION A THROUGH WINDOW JAMB FLASHING SEALANT BEAD BETWEEN FLASHING AND MOUNTING FLANGE. jz, SECURE WRB I AT HEAD _ FLASHING AT HEAD EXTENDS I" BEYOND JAMB FLASHING. IO / ' /UHEAD FLASHING SEALANTpEMBED BOTTOM CF THE HEAD / / / I FLASHING AGAINST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES O / I OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. '` NOTES: 1. flashing to be flexible self-adhesive type (min. 4" wide) sill pan flashing 2. cover sill to at least depth of window, plus 2" onto face of M 6" sloped surface (optional) 3, the pan shall direct water to the exterior over sill flashing sill plate 4. install flashing around remaining window unit 5. weather resistive barrier to form water shedding laps see note #2 6„ SILL PAN FLASHING weather resistive I barrier wall sheathing Prepared by 50AF First Coast Chapter —RIDGE VENT FLASHING W/ "Z" CLOSURES 1" PERFORATED "Z" �— POP -RIVET NTS (optiona l) WINDOW INSTALLATION METHODS N.T.S. S -1i-2013 NOTES: 1. INSTALL WINDOWS PER MANUFACTURER'S RECOMMENDATION. PROVIDED WINDOW INSTALLATION APPLICATION SHALL COMPLY WITH FBC-R703.8. PROVIDE METAL ROOFING SYSTEM PER FBC R905.4.4 SEALANT (AT VERTICAL LEG & UNDER "Z' VENTED HIP/RIDGE ROOF SHEATHING 36" WIDE VALLEY MEMBRANE ROOF FRAMING ROOD VALLEY FLASHING Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 WINDOW, DOOR, & ROOF/ FLASHING DETAILS Project Number 2017.10.3 Date 03-02-18 Drawn By Author Checked By Checker A502 Scale 7 d- 00 N co O N N M A JAMB FLASHING EXTEND JAMB FLASHING TO / I i OVERLAP SILL FLASHING. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. I /� O 1' �I i /' SEALANT SILL FLASHING SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE, O PLUMB, AND LEVEL CONDITION. USE CORROSION �\ RESISTANT FASTENERS. FASTEN WI /II W DOW MANUFACTURER PEGIFICANTDIONS.R I WEATHER RESISTANT / BARRIER -WRB / AT A 4B DEGREE ANGLE, CAREFULLY CUT THE BARRIER ON A DIAGONAL. GENTLY RAISE THE TOP EDGE OF THE BARRIER UP AND TAPE THE I TOPC.UJ ENTER TO THE EXTERIOR WRIB ESAABNOVE. � fNTERIOR VIEW TOP LEFT CORNER OF WINDOW '` NOTES: 1. flashing to be flexible self-adhesive type (min. 4" wide) sill pan flashing 2. cover sill to at least depth of window, plus 2" onto face of M 6" sloped surface (optional) 3, the pan shall direct water to the exterior over sill flashing sill plate 4. install flashing around remaining window unit 5. weather resistive barrier to form water shedding laps see note #2 6„ SILL PAN FLASHING weather resistive I barrier wall sheathing Prepared by 50AF First Coast Chapter —RIDGE VENT FLASHING W/ "Z" CLOSURES 1" PERFORATED "Z" �— POP -RIVET NTS (optiona l) WINDOW INSTALLATION METHODS N.T.S. S -1i-2013 NOTES: 1. INSTALL WINDOWS PER MANUFACTURER'S RECOMMENDATION. PROVIDED WINDOW INSTALLATION APPLICATION SHALL COMPLY WITH FBC-R703.8. PROVIDE METAL ROOFING SYSTEM PER FBC R905.4.4 SEALANT (AT VERTICAL LEG & UNDER "Z' VENTED HIP/RIDGE ROOF SHEATHING 36" WIDE VALLEY MEMBRANE ROOF FRAMING ROOD VALLEY FLASHING Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 WINDOW, DOOR, & ROOF/ FLASHING DETAILS Project Number 2017.10.3 Date 03-02-18 Drawn By Author Checked By Checker A502 Scale 7 d- 00 N co O N N M WP GFI 3 3 � H ADA WC Ik GPI , MASTER BATH -ADA WP GFI GFI GFI WP GFI a WP GFI WP WP GFIGFI _. E ......_..........__.___�..........___ _.._._._.._.._............�. _ _.._____.........�..�_.._._.._...........____.._._.........._�...._....._..__..........._.____.._...._...._...._..............�_..._�. _..�.._.................._...._ -_____.._..__...................___..._....__ _ _ 1111. �. O._......_...... COVERED PORCH MASTER BEDROOM -_O LINEN WP GFI PANTRY tzI GFI_„ 1 00, 3 3 WP GFI GFI ;11.11 ......., ..........,. �� ..,..... �.�..,..... 1111.. � I :� �� 1111... a� as .�, .�. ��. � 1111 ___ ............................_ 1111_.._ _ _ _ __ 1111._ �__.....................................�:.._,... i i ) o V E FCI Cf� GFI _1111 _......L........... � tV �; `E G I, Tj P. E, ..1111... i AFCI, T 1111_. GFI, TYP I E ;. 1 DW 7y G 1111._------------ ' w it At GFI 1111.. 1111._ pt 3 1111 ,a E , 1111....,• E _ 1111_. 11,11: O 1 i...... 1111._ 1111__. I €� F IKITHEN ; . IVI 3 ,,� _ I ..._.__ 1111.. 3 iGFI 7'-0" _1111. 1:111 I O _1111 ii ,1111.. Gr 7-0" o0 AFCI, TYR. rO WP ---- G r 1 3I 3 3 3 3 GF S S S 1111 .........................._...____ __ 1111_... ......._.. . (,VEST . I _1111.._ . 1111 _........._ ................_.........._ 1111 _1111.... _m ___ _ ----_ _....................._................._--- __ 1111. 1.... E :....................... .. ............._.....:........�: 1111..._. 11_11. L_.. ....E......... E ,.........�.. _. _ 1111._ 1111 ns 3 AFCI, TYP. 411 :I I I 3•.....�0 I � ,...__ ..............._ i f,•' E r, 4 I ._. 1111__11..11 1111 E I 1111... _ 11.........11AFCI, TYP. ._._ 1111._ .._...._._..... I l GI;.m....__....... _1111. ......m.._.,.._.___.___,_______,_� 1111..., ,_.............� _................ I 1111.1111.. 1111.._ 1111. N T GFI GH CE LING e =E B ..._..__._......_.... i 1111.FIXTU E ;1111.: 1 � � _C10...... 3S._ 1111_._ 1111.. 1111.. E €_._.............. f EE E - -------------------- ,. 1111.......... i E WIC l { ...i..._.............,_.r,..,.__. .........,.,.....,._,............_........................._...._..._..._...._.......,.,.,.........,......_._....�......._......__..1_._11._1._.._...._._._1.1._._.._11........._..;......_.....____.._.�..._. .,.... _1111__ 1111,:€ _€ €; ;� � ;;,ABOVE .. . FOYER 3 _____..__.. .......... 1111.... i_................... ' ...._..._..,...._..�._.._..w E i i AFCI, TYP. ,1111.. STAIRS3 CB-A`TH/ 1111 " 220V MUD - - I D ._._..�.....___.......� � _.-1111_.. ........:._....................� _1111_. W €;)E :l 3 : I :, 1111. u ✓�_�� �? GFI O.'` AH -1 ME[L.A"M• 0 GARAGE WP GFI GFI GFI GARAGE DOOR OPENER GFI GFI s 3 S WP GFI WP COVERED GF' - ENTRANCE/ ..........�............�:\F �E _._....... e1 :...._.: PORCH L:=_.___. GFI GFI`I WP il �........z ;GFI GFI , B WP GFI SMOKE DETECTOR, TV TYP. O STU DY WP GFI AFCI, TYR. FIRST FLOOR ELECTRICAL SCHEMATIC PLAN WP GFI ELECTRICAL LEGEND O DUPLEX RECEPTACLE WALL MOUNTED ^GFI DUPLEX RECEPTACLE ON GROUND -FAULT CIRCUIT INTERRUPTER ^AFCI DUPLEX RECEPTACLE ON ARC -FAULT CIRCUIT INTERRUPTER JB JUNCTION BOX o O ® FAN/ LIGHT COMBO o O SPECIAL OUTLET TV TELEVISION CABLE TELEPHONE PENDANT FIXTURE ,10 RECEESED FIXTURE r CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE TTTT 12"x48" FLUORESCENTE LIGHT BOX FLUSH MOUNTED SHOWER/ TUB LIGHT/ FAN COMBO OEXHAUST FAN Ej DISCONNECT SWITCH © PUSH BUTTON BS INSTALL SMOKE/ CARBON MONOXIDE ALARMS PER FBC RESIDENTIAL SECTION R314, R315 & R315.1.2 NOTES: - COORDINATE OUTLET LOCATIONS WITH OWNER - ALL LIGHTING FIXTURES TO BE SELECTED BY OWNER - PROVIDE 100% HIGH -EFFICIENCY LIGHTING PER FBC-ENERGY CONSERVATION 2014 ELECTRICAL NOTES 1. WIRE ALL APPLIANCES, HVAC, UNITS AND OTHER EQUIPMENT PER MANUF. SPECIFICATIONS. 2. INSTALLATION SHALL BE PER NATIONAL ELECTRIC CODE 2014 OR LATEST EDITION. 3. CONSULT THE OWNER FOR THE NUMBER OR SEPARATE TELEPHONE LINES TO BE INSTALLED. 4. ALL SMOKE DETECTORS SHALL BE 120V W/ BATTERY BACKUP OF THE PHOTOELECTRIC TYPE, AND SHALL BE INTERLOCKED TOGETHER. INSTALLED IN ACCORDANCE W/ APPLICABLE SECTIONS OF NEC -LATEST EDITION 2014. 5. TELEPHONE, TELEVISION, AND OTEHR LOW VOLTAGE DEVICES OR OUTLETS SHALL BE AS PER THE OWNER'S DIRECTIONS AND IN ACCORDANCE W/ APPICABLE SECTIONS OF NEC -EDITION 2014. 6. ALL MATERIALS SHALL HAVE A UL LABEL OR LISTING. 7. RECEPTACLES LOCATED WITHIN WET AREAS SHALL BE GFCI PROTECTED. 8. BRANCH CIRCUITS THAT SUPPLY 120 -VOLT, SINGLE-PHASE, 15- AND 20 -AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUN -ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL HAVE ARC -FAULT CIRCUIT -INTERRUPTER PROTECTION PER FBC 6th EDITION RESIDENTIAL E3902.16. 9. VERIFY WITH OWNER SPECIFIC LOAD DEMANDS OF EQUIPMENT AND SPECIFIC CONNECTION REQUIREMENTS 10. VERIFY EXACT MOUNTING HEIGHT AND CONFIGURATION OF SUSPENDED FIXTURES WITH OWNER. 11. SWITCH CONTROLLED LIGHT CIRCUIT FOR FLOOD LAMPS LOCATED IN SOFFIT (R=REAR F = FRONT) 12. RECESSED IN -SLAB FLOOR OUTLETS WITH SOLID METAL TRIM COVERS - VERIFY WITH OWNER SWITCHING REQUIREMENTS AND LOCATION OF SUCH SWITCHING. 13. PROVIDE DUPLEX RECEPTACLE(S) IN UPPER CABINET(S) FOR FUTURE UNDER -CABINET LIGHT UNITS - VERIFY W/ OWNER DETAIL NOTE: ALL WORK IN ACCORDANCE WITH NEC 2014 r==\,�aa0 "0"', i Niaaa�\ Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 FIRST FLOOR ELECTRICAL SCHEMATIC PLAN Project Number 2017.10.3 Date 03-02-18 Drawn By Author Checked By Checker El 01 Scale 66 77N 00 T_ O N N co WIC AFCI, 0 AFCI WIC BEDROOM 2 SO AFCI, TYP. ,. < 3 ,_.... BATH 3 ._,_ ... 3 L FT A CI, TYP. .............._.... ___.... Si _ AFCI, TYP. O : _ rn O� 1 TO -LIGHT i € SWITCH I BELOW BEDROOM 1 SECOND FLOOR ELECTRICAL SCHEMATIC PLAN 1/4"=1'-0" ELECTRICAL LEGEND DUPLEX RECEPTACLE WALL MOUNTED GFI ^ DUPLEX RECEPTACLE ON GROUND -FAULT CIRCUIT INTERRUPTER ^AFCI DUPLEX RECEPTACLE ON ARC -FAULT CIRCUIT INTERRUPTER JB JUNCTION BOX oO��FAN/ LIGHT COMBO O ® SPECIAL OUTLET TV TELEVISION CABLE 000. TELEPHONE PENDANT FIXTURE O RECEESED FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE 12"x48" FLUORESCENTE LIGHT BOX FLUSH MOUNTED ® SHOWER/ TUB LIGHT/ FAN COMBO /a EXHAUST FAN D DISCONNECT SWITCH © PUSH BUTTON ® INSTALL SMOKE/ CARBON MONOXIDE ALARMS PER FBC RESIDENTIAL SECTION R314, R315 & R315.1.2 NOTES: - COORDINATE OUTLET LOCATIONS WITH OWNER - ALL LIGHTING FIXTURES TO BE SELECTED BY OWNER - PROVIDE 1007o HIGH -EFFICIENCY LIGHTING PER FBC-ENERGY CONSERVATION 2014 ELECTRICAL NOTES 1. WIRE ALL APPLIANCES, HVAC, UNITS AND OTHER EQUIPMENT PER MANUF. SPECIFICATIONS. 2. INSTALLATION SHALL BE PER NATIONAL ELECTRIC CODE 2014 OR LATEST EDITION. 3. CONSULT THE OWNER FOR THE NUMBER OR SEPARATE TELEPHONE LINES TO BE INSTALLED. 4. ALL SMOKE DETECTORS SHALL BE 120V W/ BATTERY BACKUP OF THE PHOTOELECTRIC TYPE, AND SHALL BE INTERLOCKED TOGETHER. INSTALLED IN ACCORDANCE W/ APPLICABLE SECTIONS OF NEC -LATEST EDITION 2014. 5. TELEPHONE, TELEVISION, AND OTEHR LOW VOLTAGE DEVICES OR OUTLETS SHALL BE AS PER THE OWNER'S DIRECTIONS AND IN ACCORDANCE W/ APPICABLE SECTIONS OF NEC -EDITION 2014. 6. ALL MATERIALS SHALL HAVE A UL LABEL OR LISTING. 7. RECEPTACLES LOCATED WITHIN WET AREAS SHALL BE GFCI PROTECTED. 8. BRANCH CIRCUITS THAT SUPPLY 120 -VOLT, SING'_E-PHASE, 15- AND 20 -AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUN -ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL HAVE ARC -FAULT CIRCUIT -INTERRUPTER PROTECTION PER FBC 6th EDITION RESIDENTIAL E3902.16. 9. VERIFY WITH OWNER SPECIFIC LOAD DEMANDS OF EQUIPMENT AND SPECIFIC CONNECTION REQUIREMENTS 10. VERIFY EXACT MOUNTING HEIGHT AND CONFIGURATION OF SUSPENDED FIXTURES WITH OWNER. 11. SWITCH CONTROLLED LIGHT CIRCUIT FOR FLOOD LAMPS LOCATED IN SOFFIT (R=REAR F = FRONT) 12. RECESSED IN -SLAB FLOOR OUTLETS WITH SOLID METAL TRIM COVERS - VERIFY WITH OWNER SWITCHING REQUIREMENTS AND LOCATION OF SUCH SWITCHING. 13. PROVIDE DUPLEX RECEPTACLE(S) IN UPPER CABINET(S) FOR FUTURE UNDER -CABINET LIGHT UNITS - VERIFY W/ OWNER DETAIL NOTE: ALL WORK IN ACCORDANCE WITH NEC 2014 1 10MM ons Yellow Star Ln N Jacksonville, Florida 32224 904-716-6335 ©2018 Ogy Design, Inc. Consultant Address Address Address Phone Consultant Address Address Address Phone No. Description Date ANN & GEORGE SANTAYANA RESIDENCE ABCC LOT 6 SECOND FLOOR ELECTRICAL SCHEMATIC PLAN Project Number 2017.10.3 Date 03-02-18 Drawn By Author Checked By Checker El 02 Scale 7 00 N V_ 00 T_ O N N M