1674 Maritime Oak Dr FFE SurveyF. B. NOTES D.C. N/A DR. BY BRB DIR. P:\2017 (81358) ORDEf NO. 164867-FNL FILE 81803
MAP SHOWING BOUNDARY SURVEY OF
L 0 T 123 AS SHOWN ON MAP OF
ATLANTIC
BEACH COUNTRY CLUB UNIT 2
AS RECORDED IN PLAT BOOK 67
PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLA.
CERTIFIED TO: TOLL BROTHERS, INC.
RECEIVED
JUL 13 2018
Building Department
City of Atlantic Beach, FL
CURVE DATA C2
N06'21'25"W
CH = 43.07'
R = 335.00'
A = 43.10'
m
D �
\
A= 07.22'18"
,
g-
mm
L 0 T 1 2 2 zD
TELEPHONE WATER
RISER BOX METER
S89'27'38"E 100.22' (-2.7'
tD5'
-------------
B. R. tD .,
--- WATER ED .
METER
8.0'-
40.6' I .1
z
I
w
�d>
D
I
mn
N o f m 0.7'
$10, "i
n
0 ml `°o
r ?0
TWO STORY
WOOD FRAMEmI
�
RESIDENCE AR
1za'
-+A.D.
&0.7*
#1674 no 2' 0
F.F.E.=(14.40)
F
D CONC. P.R.M.
m
_D
z
848
P.C.
m v 13
�r _
Zz
t �+
O
61.4' N p,RC
J O '
N
4x4 CONC 18.6 O \ v
A/C
CP L — ---------------
0 —1
�I WATER
\
METER
N89'27'38"W 104.67'
(BEARING BASE) TELEPHONE WATER
HAND HOLE METER
L 0 T 1 2 4
\
o.
CURVE DATA C1
R. �.
S11'3232"E Q
CH = 61.36'
R = 235.00'
BENCHMARK:
A = 61.53'
FND NAIL & DISK
A = 1500'10"
LB 3848
AT (. P.C.P. IN FRONT
OF LOT 93 ON
MARITIME OAK DRIVE
ELEVATION: (10.86)
ELEVATIONS SHOWN HEREON
REFER TO NAVD OF 1988
NOTE:
SIDE/FRONT TIES ARE TO THE FOUNDATION.
FINAL; W.O.# 164867; 07-07-18
(FIELD)
FOUNDATION; W.O.# 1580)7;
09-01-17 (FIELD)
LOT & HOUSE STAKE OU
(GOOD-SET F.F.E.); W.O.# 157685; 08-05-17
(FIELD)
THIS SURVEY WAS PERFORMED
WITHOUT THE BENEFIT OF A TITLE COMMITMENT. O -FOUND 5/8" IRON ROD; LB #3848
THERE MAY BE ADDITIONAL
EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN
ON THIS SURVEY THAT M
Y BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. UNDERGROUND ENCROACHMENTS NOT LOCATED
THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN
ON FLOOD INSURANCE RATE MAP 0406 H FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 06-03-13
ALL
AMERICAN
SURVEYORS OF FLORIDA, INC.
LAD
SURVEYORS - 3751 SAN JOSE PLACE, SUITE 15 - JACKSONVILLE, FLORIDA, 32257 - 904/279-0088 - LICENSED LAND BUSINESS NO. 3857
FND. = FOUND e
I.D. = IDENTIFICATION
(.P.P) TYPICAL
n CONC = CONCRETE
A/C = AIR CONDITIONER
BOC BACK OF CURB
THIS IS TO CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE
- Jc
-
= IRON PIPE
I.R. =RON ROD
N.G. NATURAL GROUND
TW TOP OF WALL
SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN
AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM TECHNICAL STANDARDS SET
=4
-
o = DELTA ANGLE
CH = CHORD
=
BW = BOTTOM OF WALL
P.T. = POINT OF TANGENCY
FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS PURSUANT
ALL
A = ARC LENGTH
P.C.P. = PERMANENT CONTROL POINT
TO CHAPTER 472.027 / CHAPTER 61G17-6, FLORIDA STATUTES.
(C) RADIUS
CALCULATED
(D) = DEED
P.C. = POINT OF CURVE
P.R.C. = POINT OF REVERSE CURVE
P.C.C. = POINT OF COMPOUND CURVE
- _
SURVEY NOT VALID UNLESS-EMBOSSED BY SEAL
AMERICAN
SURVEYORS
P = PLAT
R; RADIAL LINE
B.R.L. = BUILDING RESTRICTION LINE
F.P.&L= FLORIDA POWER & LIGHT
JAMES D.- HARRISON , JR.,No. -2647
OF FLORIDA,
INC.
=
� CENTER LINE
R/W = RIGHT-OF-WAY
(A) = ACTUAL
= WITNESS
F.F.E. =FINISH FLOOR ELEVATIO
—x- = FENCE
LB =LICENSED BUSINESS
NGVD = NATIONAL GEODETIC VERTICAL
DATUM
NAVD = NORTH AMERICAN VERTICAL DATUM^_(f
. F,.6421�
MICHA&L. GARRM_ kA a�/
SCALE 1 =20(W)
-
/
9
W = WIDTH
D DEPTH
MES = M TERED END SECTION
P.I. = POINT OF INTERSECTION
EOW = EDGE OF WATER
TOB =TOP OF BANK
,r"'�
DATE 04-24-17
A ,REGF$TERED� $ YOR � MAPPER
-
_ 8
(FLOR . T _
F. B. NOTES D.C. N/A DR. BY BRB DIR. P:\2017 (81358) ORDEf NO. 164867-FNL FILE 81803