Loading...
1674 Maritime Oak RES17-0068 Roof Revision a r CITY OF ATLANTIC BEACH 800 Seminole Road tt o Atlantic Beach,Florida 32233 x REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date 6/27/2018 Revision to Issued PermitX Corrections to Comments_ Permit# RES17-0068 Project Addresa1674 Maritime Oak Drive Contractor/Contact Name Audrey Regnier Phone 904.595.5243 Email aregnier@tollbrothers.com Description of Proposed Revision/Corrections: Permit Fee Du $ :L O D \ Submitting two (2) copies of metal roof approval and install instructions roof. Additional Increase in Building Value$ Additional S.F. By signing below,i Audrey Regnier affirm the Revision is inclusive of the proposed changes. (printed name) 6/27/2018 Si um ofCon tr tor/ gen (Contfactor must sign if increase in valuation) Date ✓ (Office Use Only) Approved //Denied Not Applicable to Department n Revision/Plan Review Comments(..0��aC7 T� GJ n Tm�o CCJ 01 Department Review Required: Building Planning &Zoning Reviewed By Tree Administrator Public Works Public Utilities 7.10.20 - Public Safety Date Fire Services \CBUCK E-nlglneering Spe--lalh,l Structural Englrx%erinq CRUM In,.CC(tivm of Authorization#8064 Evaluation Report "M-Seam" Metal Roof Assembly >- CIL Manufacturer: O Millennium Metals, Inc. U U, 10200 Eastport Road U z m a Jacksonville, FL 32218 ti L) a o z (877) 358-7663 LL— 2 w ° o f0! ® U VoO Florida Product Approval p ~ ¢ o Z0 # FL 5211.3 R6 UFQ yF ¢ � z Florida Building Code 5th Edition (2014) 0 U. Per Rule 61G20-3 p O lu w a � m Method: 1 - D 3 Category: Roofing > U Fn Ic w Sub - Category: Metal Roofing ¢ � Product: "M-Seam' Material: Steel Panel Thickness: 26 gauge, (Minimum) Panel Width: 16" Support: Wood Deck Digitally signed by lames L.Buchner,P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule Y Prepared b 61G15-13. iLL kilillill, P James L. Buckner, P.E., SECS ``tLeNs ekti��' Florida Professional Engineer# 31242 Florida Evaluation ANE ID: 1916 _ Noatz4z Project Manager:Youry Demosthenes 'A : � Report No. 15-104-M-SGW-ER '0 �ATe OF �.tC :FtoamN.. G\�� Date(Revises?/1/15wER) .,ass,0NA`Et", Contents: _ Evaluation Report Pages 1-7 CBUCK,Inc. 2015.07.01 11:03:27-04'00' 1399 N.Killian Drive,Suite 4,West Palm Beach,Florida 33403 Phone:(561)491-9927- Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net FL#: FL 5211.3-R6 Date: 7/1/15 CBUCK Engineering Pagert No.:2 o04M-56W-ER Spt=claltL,l Structural EnQlneWIf-iQ CBUCK Inc.Certificate o7Authorizadon#8064 r Manufacturer: Millennium Metals,Inc. rl O Product Name: "M-Seam" U LU U_ Product Category: Roofing W Product Sub-Category Metal Roofing d Compliance Method: State Product Approval Rule 61G20-3.005(1)(d) Product/System "M-Seam" Description: 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32(min.)or 19/32'or greater plywood, • or Wood plank(min.specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: Refer to Table"A" (Refer to"Table A"attachment details herein) FL#: FL 5211.3-116 Date: 7/1/15 CSUCK Engineering Pagert No.:300a IA-Sbw-Ea Speddlty Structural Enc3Ir*t=rinq CBUGC Inc.CertificoteafAuthoizamn#80" O U w U Performance Standards: The product described herein has demonstrated compliance with: LL— • UL580-06—TestforUplift Resistance ofRoof Assemblies LL- • UL 1897-04—Uplift test for roof covering systems O Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 5th Edition(2014). • The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-04 standard version adopted by the Florida Building Code 5th Edition (2014). Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 5th Edition(2014),Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural requirements of Scope: the Florida Building Code,as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and Installation methods) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval". • Option for application outside"Limitations and Conditions of Use" Rule 61620-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61620-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section.(Dade&Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). FLY: FL 5211.3-R6 Date: 7/1/15 CBUCK Englneering Pagert No.: o 04M-S6W-ER Spedalty Structural EnQineeflnQ CBUCK Inc.Certificate of Authorization#8064 Components/Materials Roof Panel: "M-Seam" (by Manufacturer): Material: Steel Q Thickness: 26gauge Minimum U Panel Width: 16"(max.)Coverage LU Rib Height: .1" U Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: � • ASTM A792 coated, or O • ASTM A653G90 galvanized steel Fastener: Type: Pancake-Head Wood Screw Size: ff10 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME 838.6.4 Components/Materials Underlayment: (by Others): Material and application shall be in compliance with FBC Section 1507.4.5.1 and 1507.4.5.2, applicable codes and in accordance with manufacturer's recommendations. Insulation(Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf(lbs/W)min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". IFIL#; FL 5211.3-116 Date: 7/1/15 q Pagert Na.:55 of 7M-S6W-ER CBUCK Enigin�in Sppclaltl.,l Structural EnQlnpprinQ CBUCK,Inc Certificate of Authalzation#&1 Installation: Installation Method: V (Refer to drawings on Pages 6-7 of this report.) LU • Fastener spacing: Refer to Table"A"Below V (along the length of the panel) LL_ • Rib Interlock: Snap Lock. LL_ (Panel ribs shall be fully engaged to form an integral interlock.) • Minimum fastener penetration thru bottom of support,3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE"A" ALLOWABLE LOADS METHOD 1: METHOD 2: •Design Pressure: -94.25 PSF -91.75 PSF Deck Thickness: 15/32"or 19/32" 15/32"or 19/32" Fastener Spacing: 8" 4" 'Allowable design pressure for allowable stress design(ASD)with a margin of safety of 2 t 1. Install the"M-Seam" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturers installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-94&UL 1897-98 Uplift Test By Hurricane Test Laboratory,LLC(FBC Organization#TST ID:1527) Report#: 0232-0508-05, Report Date:6/29/05, Specimens#1-3 2. Quality Assurance By Keystone Certifications,Inc. (QUA ID: 1824) Millennium Metals Licensee#423 3. Equivalency of Test Standard Certification By James L.Buckner,P.E. @ CBUCK Engineering (FBC Organization If ANE 1916) 4. Certification of Independence By lames L.Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FL#: FL 5211.3-R6 Date: 7/1/15 C®UCK E-nginem2rinq Pagert NO.:6o04-M-S6W-ER Spc+dalty StrLx=hxcgl Englnenrinq CBUCK,m,.ce,tifi, re ofa8064 Installation Method Millennium Metals U "M-Seam" Roof Panel Attached to Wood Deck LU U Profile Drawings LL- LL- C) L- LLO 1" 16'Coverage Optord 66iaums 34' Typical Panel Profile View 16"o.c. Integral Snap Lock #10 Pancake-Head Screw 3/16"min. penetration thru deck � I Typical Assembly Profile View Fl-#: FL 5211.3-R6 Date: 7/1/15 CBUCK Engineering Pdgert NO.:LsoID4-M-86W-ER SpeddIFLJ Strl 1=ft c!d Enorm-princa CBUCK,Inc.Certificate of Authorization#8064 Installation Method Millennium Metals a- "M-Seam" Roof Panel Attached to Wood Deck C) W U Fastener: LL #10 Pancake-Head Scr tL "%Seam'Roof Panel _______ ______—____ __—_____--/d O f / r Typical 'E:Dsrk `— Insulation: -153Tor 19132"ar greater Plywood,or (Optional)3"manor 25 psi min. -VWod plank Typical Assembly Profile View TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: • Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32"or 19/32" 15/32"or 19/32" Fastener Spacing: 8" 4" •Allowable design pressure for allowable stress design/ASD)with a margin of safety of 2 to 1.