Loading...
1600 PARK TER W - METAL ROOF it �. ,‘ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 p;3 c.) INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF18-0080 Description: Metal Roof Estimated Value: 20000 Issue Date: 7/24/2018 Expiration Date: 1/20/2019 PROPERTY ADDRESS: Address: 1600 W PARK TER RE Number: 171966 0000 PROPERTY OWNER: Name: STREIT JILL A Address: 1600 PARK TER W ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: K & G CONSTRUCTION CO INC Address: 7587 WILSON BLVD QA AARON JAMES GALLEY JACKSONVILLE, FL 32210 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. slvy;. City of Atlantic Beach APPLICATION NUMBER t, Building Department (To be assigned by the Building Department.) r U `ice 800 Seminole Road F Atlantic Beach, Florida 32233-5445 ZOO lg-0080 Phone (904)247-5826 Fax(904) 247-5845 J;3�:' E-mail: building-dept@coab.us Date routed: 7//gpe City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1(p00 Yv K Tar - tment review required Yesi-No Applicant: t, Con+ uG Ur, Planning &Zoning I/ Tree Administrator Project: mei --C ZOO Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ATION STATUS Reviewing Department First Review: Approved. 'Denied. ❑Not applicable (Circle one.) Comments: :UILDING PLANNING &ZONING Date: /2 3 Q� Reviewed by: U - TREE ADMIN. Second Review: ['Approved as revised. ['Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. I 'Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 OFFICE, COPY U Building Permit Application Updated 12/8/17 ,, City of Atlantic Beach L�•ie f 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 D Job Address: 1600 Park Ter W Atlantic Beach, FL 32233 Permit Number: OOP (g'OO8-d Legal Description 27-6 16-2S-29E Selva Marina Unit 2 Lot 2 Blk 6 RE# 171966-0000 Valuation of Work(Replacement Cost)$ 20,000.00 Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle one): —Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential diEcENED • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New Metal Roof, 60 Squares JUL 1 8 20111 Florida Product Approval# See Product Approval Form for multiple products use product approval form Property Owner Information Building Department Name: Jill&Thomas Streit Address: 1600 Park Ter W Citof Aantic Beach, Fi. City Atlantic Beach State FL Zip 32233 Phone 904-993-4100 E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: K&G Construction Inc. Qualifying Agent: Address 7587 Wilson Blvd City Jacksonville State FL Zip 32233 Office Phone 904-772-1316 /r cog- %55�l Job Site/Contact Number 904-772-1316 State Certification/Registration# CCC1328403 CGC1511097 E-Mail ap@kandgcontractors.com Architect Name&Phone# Engineer's Name&Phone# Workers Compensation b 41.54\42Act cb.1tol.e� ,��, C, . Ex p c /O) fq Exempt/Insurer/Lease Employees/Expiration ate Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc.NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOU' NOTIC . F COMMENCEMENT. (S:nature of Owner or Agent) (Signature of Contracto 3" (including contractor) Signed9and sworn to(or affir :,)before me this ( , day of —Signed and sworn to(oor�affirme.)before me this ' day of a O / ,by t /L.. le °A'- _– __'3 L , �l v ,by j - v0Y' Go this_ It vio a of Notary) ('ture of Notary} ersonall Known OR S' .!,';;•':''' ANGELA L.MCCOY y ,j► Personally Knowq OR :.p• . Notary Public Stab o1 nom* • 4i, s MY COMMISSION#GG 032093 [ ]Produced Identificatio `-xiice, Jones I I Produced Identification is •17, Type of Identification: ommis►lon OG 101127 •e of Identification: ;�–,f., EXPIRES:September 20,2020 r•, 4-,,`,1'd,.?.' &ailed Thri,Na.y Public*Herm item ".: res 06/1 .,.,...• • Doc # 2018164912, OR BK 18455 Page 2081 , Number Pages : 1 , Recorded 07/13/2018 01 :52 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10 . 00 OFFICE, COPY NOTICE OF COMMENCEMENT ,y � (PREPARE IN DUPLICATE) Permit No.goo i tF -Oaf(' Tax Folio No. 171966-0000 State of Florida County of Duval To whom It may concern: The undersigned hereby Informs you that Improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following Information Is stated In this NOTICE OF COMMENCEMENT. Legal description of property being improved: 27-6 16-2S-29E SELVA MARINA UNIT 2 LOT 2 BLK 6 Address of property being improved: 1600 Park Ter W Atlantic Beach,FL 32233 General description of improvements. New Construction Metal Roof Owner Jill&Thomas Streit Address 1600 Park Ter W Atlantic Beach,FL 32233 Owner's interest in site of the improvement Owner Fee Simple Titleholder(if other than owner) Name Address Contractor Aaron Galley-K&G Construction Inc CCC1328403 CGC1511097 Address 7587 Wilson Blvd Jacksonvife,FL 32215 Phone No.904-772-1316 Fax No.904-771-7912 Surety(if any) Address Amount of bond S Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY •" R - Signed. Ott s. Before me this day of��t����:�� In the Cour f Duval,snot Flo' 4has pe •n y apps:red ( 1M(. 1`ate n herein by himself!iersetf and a rms lh all Statements and declarations herein -- • - are true a ».urate Notary Publ a er.- .1e of . •,l of moaery Pur tate ot flodde 1,4y comni ion ex• -s: - Svn 1 Persona:Know ass ,b00 101127 Produce,Ida•- cation �`'Z-ri.t - , I 1 REVIEWED FOR CODE COMPLIANCE OFFICE COI CITY OF ATLANTIC BEACH �` SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS / REVIEWED BY: / / '( DATE: / 3`/f uniast Metal _ rmsEL0 0ER, on Guo \ t0 _ S S- u J3 © © hE o S © s 2120 SW Poma Drive; Palm City, Florida 34990 0 772-223-4055 Phone 0 772-781-7492 Fax www.sunlastmetal.com 0 sales@sunlastmetal.com IMPORTANT NOTICE Paget READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF THE 1.50 Inch Clipless (Jax Beach Series) PANEL SYSTEM. SUNLAST METAL DETAILS MUST BE FOLLOWED TO INSURE APPROPRIATE WARRANTIES REMAIN IN AFFECT. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE INSTALLATION. NEVER INSTALL ANY PRODUCT IF ITS QUALITY IS IN QUESTION. NOTIFY SUNLAST METAL IMMEDIATELY IF ANY PRODUCT IS BELIEVED TO BE OUT OF SPECIFICATION OR HAS BEEN DAMAGED DURING SHIPPING. IF THERE IS A CONFLICT BETWEEN OUR ENGINEER'S EVALUATION REPORT AND THE DETAILS IN THIS MANUAL, THE ENGINEER'S EVALUATION REPORT WILL TAKE PRECEDENCE. Installations contained herein were in effect at the time of this installation manual creation and approved for publishing. Sunlast Metal reserves the right to discontinue products or change specifications at anytime without notice. To ensure that you have the latest material available please contact Sunlast Metal directly. Installation Details are for illustration purposes only can may not be suitable for all building designs or conditions. All projects should be engineered to conform to applicable building codes and regulations. For complete performance specifications and any disclaimers, please consult your local Sunlast Metal representative. Cufllast Metal Page 3 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless Nail Strip pax Beach Series) TABLE OF CONTENTS A. Technical Information Sheet Page 4 B. General Panel Description Page 5 C. Handling & Storage Specifications Page 6 D. Installation Requirements Page 7 E. Fastener Patterns Page 8 F. General Installation Instructions Page 9 G. General Installation Sequences Page 12 H. Flashing/Trim Metal Details Page 14 I. Installation Details 1. Eave Drip (EDBN-SS) Page 16 2. Box Gutter (BG1-SS) Page 17 3. Gable Rake (GR1-SS) Page 18 4. Peak Flashing (PF-SS) Page 19 5. Peak Flashing 2 (PF2-SS) Page 20 6. Gambrel Flashing (GF1-SS) Page 21 7. Transition Flashing (TF1-SS) Page 22 8. Ridge / Hip Cap - (RHC-SS) Page 23 9. Valley (V1-SS) Page 24 10.Side Wall Flashing (SW1-SS) Page 25 11.Side Wall Flashing 2 (SW2-SS) Page 26 12.End Wall Flashing (EW1-SS) Page 27 13.End Wall Flashing 2 (EW2-SS) Page 28 Cunlast Metal Page 4 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1-Inch Nail Strip (Stuart Series) TECHNICAL INFORMATION SHEET 1. Minimum Recommended Slope is 2:12. For slopes less than 3:12, please refer to Florida Build- ing Code (FBC)section 1507.4.2 and/or FBC section 1515.2. 2. Support Type: Wood Deck- 15/32" (min)or greater Plywood, or Wood Plank(0.42 min specific gravity) 3. 1.5-Inch Nail Strip Panels are a Concealed-Fastener, Standing Seam Metal Roof Panels with interlocking rib seams and fastening flanges for ease of installation. They must be installed over a completely waterproofed structure in order to ensure watertightness. If the waterproof mem- brane is mechanically attached with metal fasteners of any type, fasteners should be covered to protect the under-side of the metal roof panels, or the use of non-corrosive, plastic tags can be used if applicable manufacturer of the fasteners and FBC permits it. Any mechanically attach- ment device that does not lay flat on the deck will telegraph through the panels and appear as oil canning. 4. Underlayment specifications will be determined at time of estimate, but all underlayment will be in compliance with FBC Section 1507.4.5. 5. Insulation is optional, but must comply with FBC Section 1508. When insulation is incorpo- rated, fastener length shall conform to penetrate through bottom of support a minimum of 3/16". General Insulation Details: Type: Rigid Insulation Board Thickness: 3" (Max.) Density: 2.25 pcf(lbs/ft') min., or Compressive Strength: 20 psi (Min.) 6. Panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the panel at or near the point of attachment. Oil canning is not a cause for rejection of the panels. 7. For the proper fastener application, please see the Fastener Pattern section of this installation manual. Fastener spacing across the width of the panel are shown on Page 8. For fastener spac- ing along the length of the panel, use the wind upload table on the bottom of Page 8 in conjunc- tion with the local governing code. 8. For continuous panels over 30 feet, please contact Sunlast Metal for direction. SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE §unlast Metal Page 5 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless(Jax Beach Series) GENERAL PANEL DESCRIPTION ti PANEL NAME: 1.50" Clipless Snap Lock (Jax Beach Series) PANEL MATERIAL: Steel PANEL THICKNESS: 24 Gauge (Min.) PANEL WIDTH: 15" to 19" Coverage PANEL RIB HEIGHT: 1.50" YIELD STRENGTH: 40 ksi min. CORROSION RESISTANCE: In compliance with FBC Section 1507.4.3 ASTM A792 Coated, or ASTM A653 - G90 Galvanized Steel COATINGS / FINISHES: Galvalume Plus®w/Additional Acrylume® (Mill Finish) Kynar 500 FSF® OPTIONAL STIFFENING RIBS: Striations, Ribbon Beads, Pencil Beads (Flat - Standard) SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE jun!ast Metal Page 6 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless pax Beach Series) HANDLING & STORAGE SPECIFICATIONS The information provided are suggested guidelines and not intended to cover all applications or building requirements. It is the responsibility of the designer/installer to ensure that this information meets particular building conditions and/or code requirements. It is also the responsibility of the installer to ensure that all OSHA and/or other safety regulations are understood and upheld. Sunlast Metal will not be held liable for any claim which arise out of handling or installation of the material. PERSONAL HANDLING PANEL INSPECTION When handling metal panels care should be taken to All material should be inspected upon delivery. Any protect the panels from scratching or abrasion. Pulling damage or moisture intrusion should be reported to a panels across one another may cause scratches to the Sunlast office representative within 48 hours and surface film. Individual panels should be carried vertical notated on the Delivery Ticket. to the ground to avoid bending the material. MECHANICAL HANDLING FIELD CUTTING A forklift or crane can be used to handle unopened Some field cutting and fitting of pre-manufactured bundles, but care must be taken to ensure equal panels is to be expected. Minor field corrections is distribution of weight across the entire panel. Spread considered normal operation. Always cut one panel at the forklift forks to their maximum width in order to a time. For small cuts, hand-held shears (tin-snips) can ensure equal weight distribution. Use of a spreader bar, be used. For best results an electric shear may prove when using a crane, will enable equal distribution of useful. After cutting metal panels, ensure that all metal weight. Cable supports should be avoided at all costs. shavings are removed from the panel before installation to avoid rust stains, which will void the warranty. PROTECTING & STORING FASTENING DETAILS Material should be left in a secure location to avoid the The use of proper fasteners and installation procedures possibility of theft. To protect the metal panels from is an important factor in the overall appearance and weather conditions it should be tarped (non-plastic performance of the metal roofing system. When using material) and stored at least 4" above ground with one metal fasteners with weather seal washers (WSW), be end elevated slightly higher to allow moisture to run off. sure that you do not over tighten - causing the sealing If metal panels become wet, they should be individually material to extrude beyond the edge of the washer. removed from the bundled stack and dried. Prolong Also, not tightening the fastener enough will not allow storage is not recommended. If immediate installation the proper compression of the washer to seal the is not possible, additional care should be taken to penetration. ensure that rust or watermarks do not develop. Do not store sheet metal roofing materials in contact with other materials that might cause staining, denting or other surface damage. Store sheet metal materials away from uncured concrete or masonry. SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE Cunlast Metal Page 7 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless pax Beach Series) INSTALLATION REQUIREMENTS SEALANT I SEALANT WOOD DECK Wood Deck (15/32") SEALANT SEALANT Integral Snap Lock Clip Relief Seam Adhesive #10 x 1"Pancake-Head Wood Screw METAL PANELS: 24 Gauge (Steel) INSTALLATION METHOD: Refer to drawings on Page 8 FASTENER SPACING: Refer to Table"A"on Page 8 FASTENER TYPE: Pancake-Head Wood Screw FASTENER SIZE: #10 x 1" FASTENER CORROSION RESISTANCE: Per FBC Section 1506.6 and 1507.4.4 FASTENER STANDARD: Per ANSI /ASME B18.6.4 MINIMUM FASTENER PENETRATION: Through bottom of support-minimum 3/16". PANEL RIB INTERLOCK: Snaplock (Panel Ribs shall be fully engaged to form and integral snap-lock) SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE Cunlast Metal Page 8 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless Wax Beach Series) FASTENER PATTERNS SUNLAST BEACH SERIES 1JAX.5 r OPTIONAL STIFFENING RIBS ADHESIVE ON BOTH SIDES OF SEAM NiN1 :110•4(1, p 14 FASTENERS EVERY 6" IN FIELD ZONE 4,4 FASTENERS EVERY 3" IN CORNER ZONE TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeters and Corners Maximum Design Presswes -97.25 psf -161 psf Screw Spacing 6" c.c. 3" c.c. Applied continuously an Applied continuously on Seam Adhesive both sides on male leg. both sides on male leg. =Maximum Design Pressures include 2:1 Safety Factor SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE Cunlast Metal Page 9 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless(Jax Beach Series) GENERAL INSTALLATION INSTRUCTIONS The information provided are suggested guidelines and not intended to cover all applications or building requirements. It is the responsibility of the designer/installer to ensure that this information meets particular building conditions and/or code requirements. It is also the responsibility of the installer to ensure that all OSHA and/or other regulations are understood and upheld. Sunlast Metal will not be held liable for any claim which arise out of handling or installation of the material. GENERAL PANEL INSTALLATION There are three main measurements that are critical when installing metal roof panels: the length required at the eave, the peak end and the amount of panel lap (if required). In each case a certain measurement is required. Check each measurement to ensure panel placement gives you the distance required at the eave and peak. In most cases, any variance can be taken out at the eave or peak. Insure that the structure is square and true before beginning panel installation. If the structure is not square, the panels will not properly seal at the side-laps. Start the first panel square to the eave by using the 3, 4, 5 Triangle Method (See Below). Green or damp lumber is not recommended. Moisture released from the damp lumber may damage the metal panels. Nails installed on green or damp lumber may back out. Drive fastener so that it is secure against the metal but does not bind. Overdriven fasteners will also increase the amount of oil canning that is present in the metal roof panels. Do not leave any fasteners that missed the substrate. Remove any loose shavings left on the roof immediately to prevent corrosion or rust. After installing the roof system, remove any de- bris such as leaves or dirt to prevent moisture from getting trapped on the panels. TRIANGLE METHOD 1. Establish a line from Point A to Point B by temporarily marking each point with a nail. The line must be parallel to the eave. In this example, we are going to determine that this line is going to be 3 feet in length (This is the"3"side of the Triangle). NOTE: For larger 3, 4, 5 Triangles- multiply each side of the triangle by the desired increase in size. For example, if the roof panels are 25 feet from the Eave to Ridge, multiply each side by a factor of 6 for an 18, 24, 30 Triangle. Obviously the shorter the vertical length of the triangle is, the better accuracy you will have when squar- ing off. 2. Using two tape measures, locate Point C by hooking one tape measure to the nail at Point A and a second tape measure at Point B. Extend the tape measures until they cross and meet at 4ft on the Point A tape measure and 5ft on the Point B tape measure. Then place another temporary nail at this juncture. 3. Hook a chalk line onto Point A and pull it in line with Point C and then mark you chalk line on the roof deck. This will be your square reference line for the panel installation. 4. Mark chalk lines parallel with the square reference line out ahead of the panel installation so that panel square can be checked as the panels are installed. Suggested line spacing is one foot beyond 3 panels wide or about 7 feet. 5. Check for square by measuring the distance from the installed panel edge to the chalk line at both the eave and ridge ends. If the measurements match, then the installed panels are square, if not, adjustments must be made to bring the panels back to square. NOTE: Please take care when attempting to adjust for square. If completed improp- erly then oil canning will become present. 6. See the following pages for a step-by-step process. SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE Cunlast Metal Page 10 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless(Jax Beach Series) t' NIP I 11 ` ` Using two tape measures,locate Point C POINT C ©4 by hooking one tape measure to Point A and the other tape measure to Point B, RIDGE then extending both tape measures until ..7,..-,'",-,7-.`-'4g$:,,,,-,.:- _ 1; they cross at the 4ft and 5ft increments (shown here).Then place a temporary nail ,' CQat this intersection. �� - .4,‘ _ These are the 4ft and 5ft sides of the 3...4...5...Triangle. X " o y t4, r o - \ IA m ' POINT B POINT A VAIIIIIMmil&Eill lila EAVE VE° 7,_ CID ----„, Establish a line from Point A to Point B by temporarily marking each point with a nail.The line must be parallel to the eave and in this example 3ft Long(This is the 7 \ "3"side of the 3...4...5...Triangle). `A POINT C RIDGE : 0 Connect a chalk line to Point A's nail and then pull it to Point C's nail.Then `"' mark your chalk like on the roof deck. This is your square reference line for your panel installation. .o X CA m � ;11m ` NOTE: For larger distances just multiply each POINT A side of the triangle by the desired size. For instance if the Eave to Ridge height EAVE is 25ft then multiply each side by 6 to -- _. get an 18...24...30... Triangle. SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE unlast Metal Page 11 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless(Jax Beach Series) 4 Use two tape measures,on at the ridge \ and eave ends of the Square Reference Line and measure out 1 foot past 3 panel wide,or up to a maximum of 10 feet. Then hammer another temporary nail at the eave and run a chalk line to the ridge at the same length. RIDGE 1 2 3 4 5 6�\ NMI 10 CR 0 . ` D 11 m m rRI 1 41 co 0 AIL. 'a z .. 1 2 3 4 5 6 7 8 911W EA Check for square by measuring the © — distance from each installed panel edge to the " —' chalk line at both the eave and ridge.If the measurements do not match,then the ! installed panels are not square and need to be 2 adjusted.Be careful not to cause oil canning when attempting to adjust panels. 71 F----7 2 f SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE Cunlast Metal Page 12 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless (Jax Beach Series) INSTALLATION SEQUENCES v i1 \ 1. Moisture Barrier- Install 2. Fascia Trim - Install the fascia trim 3. Eave Trim - Install the Eave Trim Moisture Barrier according to the along all eaves and rakes. along all eaves lapping over Fascia manufacturer instructions. Trim. /M r 4r , 4.Valley Trim - Install the Valley 5. Metal Roof Panels - Install the 6. Hip Trim- Install the Hip Trim over Trim over the Eave Trim, working panels over the Eave and Valley Trims. the Metal Roof Panels just installed. from the Eave to the Valley Peak. Do not install panels where the trim laps under the panels. lt\ lir-- /'5 .', '''--•--'- 1/42/ ,„, ..'4- �rsev .„-,,i- - 'V': ii ,:00". \ 7. Ridge Trim- Install the Ridge 8.Transition Trim - Install the Transi- 9. Metal Roof Panels -Complete the Trim over the Hip Trim intersection tion Trim over the low slope panels and panel installation - installing the high and valley peak. moisture barrier. panels over the Trim Transition and the remaining exposed locations. SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE cjunlast Metal Page 13 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1.50 Inch Clipless(Jax Beach Series) INSTALLATION SEQUENCES - CONTINUED / , 41011p____,1:7,),, , i /, 10. Rake Trim- Install the Rake 11. Peak Trim_.- Install the Peak Trim 12. Ridge Trim - Install the Ridge Trim Trim over the panels along all Gable over the panels. over the Panels. Rake edges. , ,„.,!.:, —, •;\,.,, ,.:-_. 1 s • '%"" ' ,' 't,,,,..— --------. ' ' 0 13. Side Wall Trim - Install Sidewall 14. Side Wall Trim (Rear View) 15. End Wall Trim - Install End Wall Trim over the panels. Trim over the panels. SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE Cunlast Metal Page 14 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1,50 Inch Clipless(Jax Beach Series) FLASHING / TRIM METAL DETAILS BULLNOSE EAVES DRIP BOX GUTTER (6" STANDARD) 4"- 1" 1" 2-1/2" 3/4" i 1" 6" 2-1/2" 5" 1/2" h— 6" S.O. =8" S.O. = 22-1/4" (Standard) GABLE RAKE PEAK / HIGH END FLASHING 3-3/8" — 3/4" 1/2" 3-1/2" 5" l 1/2"--- = 5-1/8" SO. = 11" GAMBREL FLASHING TRANSITION FLASHING 6" 6" 6" 3/4" 3/4" S.O. = 12-3/4" S.O. = 12-3/4"" SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE Cjunlast Metal Page 15 OFFICE: (772)223-4055 TOLL FREE: (877)8-METAL-6 FACSIMILE: (772)781-7492 PRODUCT INFORMATION 1,50 Inch Clipless(Jax Beach Series) FLASHING / TRIM METAL DETAILS (cont.) RIDGE / HIP CAP (HEMMED) VALLEY 1" 5-1/4"- 3/4"Hem S.O. = 12" S.O. = 20" SIDEWALL FLASHING END / HEAD WALL FLASHING 4" 4" L 3/4"- 3/4" S.O. = 9-3/4" S.O. = 9-3/4" Add'I. Flashing/Trim Details STUCCO STOP ,cr 1-1/2"--i a r 2 h" 2.. 3/8" Gable Cleat i.. Valley Cleat s%" 'I," SEE SUNLAST FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE i Page 16 EDBN . Ss )11P. .„, i ilii ir;; 4 1 1 11i 2" = Cleat \ ' #10 x 1" Pancake-Head Wood Screw Bullnose Cleat Sunlast Metal, Inc. DRAWN #30 Felt (Min.) CvHame ECKED JAR Eave Drip - SS Name JR (Bullnose) ENGINEER Plywood Decking (15/32" Min) Name JAR sizE DWG NUMBER APPROVED JR A EDBN-SS SCALE 2: 1 REV A SHEET 1 OF 1 Page 17 BG _ss • #10 x 1" Pancake-Head Wood Screw 1/8" x 3/16" Stainless Steel Pop Rivet Box Gutter Strap (Sized to Gutter) Box Gutter (6" x 6" Standard) Sunlast Metal, Inc. DRAWN Name JAR #30 Felt (Min.) Name D JR Box Gutter 1 - SS ENGNEER Name Plywood Decking (15/32" Min) APPROVED JAR SIS DWG NUMBER Name JR A BG1-SS SCALE 2: 1 REV A ISHEET 1 OF 1 i Page 18 GRI _ss —11 Z -Doslos ure 1-518` ..rumu;nx; 1-i18"_4 Gable Cleat 2-1/2" #10 x 1" Pancake-Head Wood Screw 1/2" Buytl Tape Sealant Pop Rivet (Stainless Steel) Sunlast Metal, Inc. #30 Felt (Min.) DRAWN JAR Name b JR GABLE RAKE 1 - SS Plywood Decking (15/32" Min) ENGINEER Name JAR SIZE DWG NUMBER APPROVEDmJR A GR1-SS SCALE 2:1 REV A I SHEET 1 OF 1 4' Page 19 pF,...ss 1 0 0 +: a ii ..,, :ow 1,.: .4100, Aire fi.i/,/7„?/,//,//,.''i, ui •••• H 41 Z71_7_ I. 18' �-11 #10 x 1" Pancake-Head Wood Screw Pop Rivet (Stainless Steel) 1" Z-Closure 1/2" Buytl Tape Sealant Sunlast Metal, Inc. DRAWN Name JAR #30 Felt (Min.) Name° JR Peak Flashing - SS ENGINEER JAR SIS DWG NUMBER Decking (15/32" Min.) NameVED JR A PF-SS ____ SCALE 2:1 REV A 1 SHEET 1 OF 1 i Page 20 pF2 -ss O 0 I O N \ , .0., 0 vsc!,. -_,_ -- """ 1 _______-- ,ii!aiii iii, 1-1------i J 1, Z-Closure 1-5/W NO 1-1/B'- 41 C le'3 IL 2-1/2 / A #10 x 1" Pancake-Head Wood Screw Pop Rivet (Stainless Steel) 1" Z-Closure 1/2" Buytl Tape Sealant 1 Sunlast Metal, Inc. DRAWN Name JAR CHECKED #30 Felt (Min.) Name JR Peak Flashing2 - SS ENGINEER Name JAR SIZE DWG NUMBER Decking (15/32" Min.) NameVED JR A PF2-SS SCALE 2:1 REV A I SHEET 1 OF 1 i Page 21 Gn _ss _Iiiiiii.......„. 1111111111111111 .. _J.. __ Z- �C � 8' I N 411 1/ #10 x 1" Pancake-Head Wood Screw Buytl Tape (1/2" Min.) Sealant Z Closure Sunlast Metal, Inc. #30 Felt (Min.) DRAWN JAR CHECKED GAMBREL Name JR FLASHING 1 (SS) Plywood Decking (15/32" Min) ENGINEER Name JAR slzE DWG NUMBER APPROVED JR A GF1-SS SCALE 2: 1 REV A I SHEET 1 OF 1 i Page 22 TF1 _ss 1.. ._1 __.1 „„„ ,,„,, „ ,,, -L7, ,,,, Z- forge 1-5/8” ariiiiirsoftes, #10 x 1” Pancake-Head Wood Screw 1/2" Buytl Tape Sealant Z-Closure Sunlast Metal, Inc. #30 Felt (Min.) DRAWN Name CHECKED JAR TRANSITION Plywood Decking (15/32" Min) Name �EER JR FLASHING 1 (SS) Name JAR SIZE DWG NUMBER -APPROVED JR A TF1-SS SCALE 2: 1 REV A I SHEET 1 OF 1 i Page 23 RHC-ss . . li..„..0 ..tom►� .. •"77.7.0 '-'1114\ V ,ft...•...... .... 110 1., 1* ____T , 11 -CIos ure 1-518" i-lf$' #10 x 1" Pancake-Head Wood Screw Pop Rivet (Stainless Steel) 1" Z-Closure 1/2" Buytl Tape Sealant Sunlast Metal, Inc. DRAWN Name JAR #30 Felt (Min.) Name D JR Ridge/Hip Cap - SS ENGINEER JAR SIS DWG NUMBER Decking (15/32" Min.) Name ED JR A RHC-SS SCALE 2: 1 REV A SHEET 1 OF 1 Page 24 V min S S 10 2 .r 3/8" Valley Cleat #10 x 1" Pancake-Head Wood Screw Valley Cleat Butyl Tape Sealant Sealant Sunlast Metal, Inc. DRAWN Name JAR #30 Felt (Min.) Name D JR Valley 1 - SS ENGNEER Name JAR gin DWG NUMBER Plywood Decking (15/32" Min.) NaeVED JR A V1-SS SCALE 2: 1 REV A I SHEET 1 OF 1 i Page 25 SW Ss • I ..• semi , Z- 1a5t1F� 1-�:8' #10 x 1" Pancake-Head Wood Screw Buytl Tape 1-���' Z-Closure Stainless Steel Pop Rivet Sealant Sunlast Metal, Inc. DRAWN Name JAR CHECKED JR Side Wall 1 - SS #30 Felt (Min.) ENGINEER Name JAR SIZE DWG NUMBER APPROVED Plywood Decking (15/32" Min.) Name JR A S\A VV/1-SS SCALE 2: 1 REV A SHEET 1 OF 1 Page 26 sw2 Ss v \ 1/2' 2" •• menti momail Counter Flashing 1/4" 2" Closed Hem 7-Closure L ' #10 x 1" Pancake-Head Wood Screwlefr--( #10 x 1-1/2" Hex-Head Wall Screw (Counter Flashing) Counter-Flashing (5-1/2" S.O.) Buytl Tape Z-Closure Stainless Steel Pop Rivet Sunlast Metal, Inc. Sealant DRAWN Name JAR CHECKED Side Wall 2 - SS Name JR #30 Felt (Min.) ENGINEER Name JAR SIZE DWG NUMBER Name ED JR A SW2-SS Plywood Decking (15/32" Min.) SCALE 2: 1 REV A SHEET 1 OF 1 Page 27 Ew Ss V Z-Closure .0 #10 x 1" Pancake-Head Wood Screw Buytl Tape Z-Closure Sealant Sunlast Metal, Inc. DRAWN Nme #30 Felt (Min.) E ED JJAR End Wall 1 - SS Name JR ENGINEER Plywood Decking (15/32" Min.) Name APPROVED JAR SIZE DWG NUMBER Name JR A EW1-SS SCALE 2: 1 REV A SHEET I OF 1 i Page 28 Ew2 Ss _ /\ V 7/4" vr" - inaununi M I'li 2" Counter Flashing N. , ,, 1 7- 1/4" T Closed Hem n" Willi allm10 y : IIIIIIMMMlmmmmmmr II Z-C[os ure 1-5/8" #10 x 1" Pancake-Head Wood Screw 1-118 #10 x 1-1/2" Hex-Head Wall Screw (Counter Flashing) Counter-Flashing (5-1/2" S.O.) Buytl Tape Z-Closure Sunlast Metal, Inc. Sealant DRAWN JAR CHECKED JR End Wall 2 - SS #30 Felt (Min.) ENGINEER Name JAR SIZE DWG NUMBER APPROVED JR A EW2-SS Plywood Decking (15/32" Min.) SCALE 2:1 REV A I SHEET 1 OF 1