Loading...
114 JACKSON RD - ATTACHED TOWNHOUSE CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0192 Description: 114 JACKSON RD -ATTACHED SINGLE FAMILY Estimated Value: 291508.65 Issue Date: 8/3/2018 Expiration Date: 1/30/2019 PROPERTY ADDRESS: Address: 110 JACKSON RD RE Number: 172137 0000 PROPERTY OWNER: Name: V ALLISON FORSYTH Address: 1738 SELVA MARINA DR ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: MATHIEU BUILDERS Address: 38 W 9TH ST QA DUSTIN MATHIEU BROWN ATLANTIC BEACH, FL 32233 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. rj1"1TfjJr 6), Permit Conditions 40 1~ City of Atlantic Beach '-(LQ)0J%' Permit Number: RES18-0192 Description: 114 JACKSON RD-ATTACHED SINGLE FAMILY Applied: 5/31/2018 Approved: 7/11/2018 Site Address: 110 JACKSON RD Issued:8/3/2018 Finaled: City,State Zip Code:Atlantic Beach, Fl 32233 Status: ISSUED Applicant: <NONE> Parent Permit: Owner:V ALLISON FORSYTH Parent Project: Contractor: <NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 6/5/2018 DRIVEWAY APRON INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All concrete driveway aprons must be 5"thick,4000 psi,with fibermesh from edge of pavement to the property line.Reinforcing rods or mesh are not allowed in the right-of-way. (Commercial driveways-6"thick). 2 6/5/2018 EROSION CONTROL INSTALLATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(247- 5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 3 6/5/2018 ON SITE RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site during construction. 4 6/5/2018 POST CONSTRUCTION TOPO INFORMATIONAL SURVEY PUBLIC WORKS Scott Williams Notes: If on-site storage is required,a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. 5 6/5/2018 ROLL OFF CONTAINER INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapell's,Inc.,Republic Services,Donovan Dumpsters). Container cannot be placed on City right-of-way. Printed: Friday,03 August, 2018 1 of 2 • -'Q Permit Conditions City of Atlantic Beach 6 6/5/2018 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. 7 6/5/2018 CONSTRUCTION SITE INFORMATIONAL MANAGEMENT PUBLIC WORKS Scott Williams Notes: Provide construction site management plan,including location of silt fence,dumpster,portable toilet. Right-of-Way Permit is required if using right- of-way for construction parking. 8 6/5/2018 RUNOFF INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All runoff must remain on-site. Cannot raise lot elevation. 9 6/5/2018 MAXIMUM DRIVEWAY INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Maximum driveway width within the City right-of-way is 20'. 10 6/5/2018 REVISION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Any plan change must be submitted as a Revision to the Building Department. 11 6/5/2018 UNDERGROUND WATER SEWER INFORMATIONAL UTILITIES PUBLIC WORKS Kayle Moore • Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5834. 12 6/5/2018 METER BOX SEWER CLEAN OUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible. 13 6/5/2018 RT1 SEWER CLEANOUT INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. Printed: Friday,03 August,2018 2 of 2 OFFICE COPY— " ' Building Permit Application Updated 12/8/17 City of Atlantic Beach 800 Seminole Road,Atlantic Beach,FL 32233 J Phone:(904)247-5826 Fax:(904)247-5845 0 Job Address: / I t')2 c2 ,Pal Permit Number: R c Si GQ, ` -( 9 Z. Legal Description t&\10/ Li'f /S P/ * gook S, /ay , / (,/V/43)' RE# .pi / p 17 Z I3 - ODD CD Valuation of Work(Replacement Cost)$ 1? D°b Heated/Cooled SF lb 'Y/ Non-Heated/Cooled o,/,3-3 • Class of Work(Circle one):IMAddition Alteration Repair Mov Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commerci Residential • If an existing structure,is a fire sprinkler system installed?(Circle one : Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Neitiseey).5-0vc ,w, o•>C -,/15 /: wl -4 / ltd G Q HCl' �f'iwe Florida Product Approval# o for multiple products use product approval form Property Owner Information �/ {fin ,-;\ , Name: U 6 II,'S 0(\ t, ) 664 TY� Address: ) '1 8 5N__�U a !l lCvL(/V!d A . City 1=)T.Ic,( 0 e.,h state F I , zip �a Phone R 0 °-1 - 7-1/r? 3 7-9 E-Mail (j-fo( /CI'io c , no) .CL►YY7 Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Contractor Information Name of Company: 111 c�.'}fn 1 p� I U)1 i C2 6 Qualifying Agent: U 5 +r r B{,o t,o n i j Address 3 b' , `\ City } JCOs/c' ',14‘ State 0 Zip .'3 07,i'3 Office Phone �'{O 9 31 -i i 'i',1 Job Site/Conte Number State Certification/Registration# (3 C_ / -_ 6 E-Mail h 1 C.A )e.jj OC COVN,Ca./a n� Architect Name&Phone# ha f IF LQ✓tk_eS Engineer's Name&Phone# '" l Workers Compensation =Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to ork and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc.NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. V . 4AL;,1 at /7,3.4-4, //'__ (Signature of Owner or Agent) (•: ature of Contractor) (includin: .•%tractor) ed and sworn to(or affir -d)b:fore • - this •ay o Signed and sworn to(or a irm•d)be ore me his •ay of 1 V v.-+� 7©(C ),by A.4.1 MI AM—.2 v mq7 2.9 ,Zo( 8 •\ 4U ; ,,�,A o _ — �f _ /� Signature of Notary) _~ Signat - . o ary) _ rsonally Known OR ,, ,;'r TONI GINDLESPERGER j personally Known OR ""- —`r— ::? , ;,,+;i;, TONI GINDLESPERGER Produced Identification ,+ MI :+%, MY COh MISSION N FF 924951 Produced Identification �' I 1 wii-MI •• - I I MY COMMISSION it FF 924951 Type of Identification: ";•: 43= EXPIRES:October 6,2019 :* Type of Identification: a,. XPIRES:October 6,2019 '•4;RF F`.: tended Thru Notary•u•to en.-" ers OFFICE COPY PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft') J6 y/ Non-Habitable Space (ft") LAND INFORMATION: Zoning District Flood Zone Minimum FFE BUILDING INFORMATION: Construction Type Occupancy Group Number of Stories Max Occupancy Load Fire Sprinklers Required CONDITIONS/ COMMENTS: Rev. 2.7.2018 ?S::L`:,,, City of Atlantic Beach APPLICATION NUMBER tiejli r Building Department (To be assigned by the Building Department.) ""A `� 800 Seminole Road ( r Q e Atlantic Beach, Florida 32233-5445 �t S `� r 0` ` 2 Phone(9 04) ing-de 247-5826 • Fax(904)247-5845 �/� f /� p ;I_1..:)-) E-mail: building-dept@coab.us Date routed: ( [1/ 0 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l 1 4 Jackson Rd I - • - ment review required Yes No Buildi • �^ in• &Zonin. Applicant: Ir �&tkie 1,4_ �lJ�-i �� Tr P Adm" istrator Project: pp() CIA_st -c+ bre Public Wo u lic Utiliti& Public Safety • Fire Services Revjew fee $°'A. ,,r. ':II; . < ,°t .:::1 0<:s a. Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. cADenied. ['Not applicable (Circle one.) Comments: BUILDING Need it/C lei k PLANNING &ZONING Reviewed by: /5-69 Date: v 9 12 TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: / PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: / 6 Date: ?la-)2 FIRE SERVICES Third Review: Approved as revised. ElDenied. [Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 i=-L'fr.,, TREE & VEGETATION AFFIDAVIT FOR INTERNAL OFFICE USE ONLY 's+o\ City of Atlantic Beach PERMIT# � �� .• Community Development Department 800 Seminole Road Atlantic Beach,FL 32233 ':!o )>'' (P)904-247-5800 SITE INFORMATION ADDRESS /I i71 • ,7 -Y-) /?u h7f-41 /G ?Jt /7. c3,71.,),.. ....3 p / / SUBDIVISION TO-C-Su rf i 1dkGL t' tzlLL bon nen,� Pid- BLOCK iS LOT r_>( RE# / 0113 7 - 0000 ❑ RESIDENTIAL ❑ COMMERCIAL ❑ OTHER APPLICANT INFORMATION l / ,/ NAME l/ so, r\6 l 11�So \ W - h t�`TV\ PHONE# q — //a,37? 4 ADDRESS , 7,j8 e!Ue( 14Gv1AA/\Q b /) Ali. CELL# ,r CITY M), L) STATE rf ZIP CODE j;707 3 ji EMAIL I,-r,,- 196e,) a101. terve NER ❑ LEGAL AUTHORIZED AGENT I affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation", of the Municipal Code of Ordinances for the City of Atlantic Beach Florida and/or I have participated in a pre- application meeting with the Administrator of those regulations. Subsequently, I affirm that no regulated trees and no regulated vegetation will be damaged,destroyed and/or removed from the above-described property and/or adjacent properties including right-of-way. I HEREBY CERTIFY THAT ALL INFORMATION PROVIDED IS CORRECT:Signature of Property Owner(s)or Authorized Agent ,V0 A.I . i A . _ . ..._..e V )9/i gym. li1 )::-: cf ,5-J9-ie SIGNATURE OF •PPLICANT PRINT OR TYPE NAME DATE SIGNATURE OF APPLICANT(2) PRINT OR TYPE NAME DATE O t Signed and sworn before me on this 2day of ,7 � y State o County of IIM Identification verified: ii4 Oath Sworn: ❑ Yes ❑ No Notary Signature TO GAOL SPERGER '',�. ..e= MY CO,MiSSI• ii FF 924951 tet �Y ;t= My Commission k'> :.' EXPIR •ber 6,2019 '•. r;f:'' BcndedThruNotaryF`ubirc�nde�m�ti 04 TREE AND VEGETATION AFFIDAVIT 03.01.2018 ""'""� s'`a''c City of Atlantic Beach 1APPLICATION NUMBER rj Building Department (To be assigned by the Building Department.) ' A • `• 800 Seminole Road R- I Q j- ! Atlantic Beach, Florida 32233-5445 l'� S l g - Q l 2 Phone(904)247-5826 • Fax(904)247-5845 �/� / /� o; 9' E-mail: building-dept@coab.us Date routed: ( l(City web-site: http://www.coab.us 1 APPLICATION REVIEW AND TRACKING FORM Property Address: t t4 JathSort Rd Rct tment review required Yes No Bd Applicant: R—{ ie l. 4-TGen g &Zonin nI .�-� Tr . istrator Project: 1'kc3 l �`> - v(4"l 6n Public Wo u lic Utiliti Public Safety Fire Services Review fee $ 5 d Dept Signature :.:. Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 1 Approved. ['Denied. ['Not applicable (Circle one.) Comments: "�" BUILDING Plak►S 'fpO (at�� Il- Loirty- 'cV►e- PLANNING &ZONING G✓ lam' Reviewed by: Date:C� 1� TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable PU ORKS Comments: ET:, U PUBLIC S FETYY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 u tit_ '` City of Atlantic Beach ' PUBLIC UTILITIES DEPARTMENT `' 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904)247-5834 NEW WATER / SEWER TAP REQUEST Date 60 - LI — ( v Project Address 7 / `/ L]' ?e, 5 61') /4) Number of Units ICommercial Residentialy7 Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) `�'z-( New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer V Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature ` CITY STAFF USE ONLY Application 4 0—_ / 3 - 0 / 1 z N€w oNr.‘) eT rJ Water System Development Charge $ 1 / /O, UCS Sewer System Development Charge $ -r/ 03-01 06 Water Meter Only $ Reclaim Meter Only $ Water Meter Tap $ eOo oo Sewer Tap $ Cross Connection $ 50, on Other $ TOTAL $ SP i 0 YO‘ 0D (Notes) APPROVED Kayle Moore, P.E. 1 Date a cf t ct Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED sLAN: City of Atlantic Beach APPLICATION NUMBER JSP Building Department (To be assigned by the Building Department.) 1 800 Seminole Road Atlantic Beach, Florida 32233-5445 RES [ '� O Lf of 2 "�J;3>>' E-maPhonil:( b0u�d ng-dept@coab.u904)247 5845 Date routed: 5/3 i/f 0 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l 14 Jackson Rcl • - ment review required _ No Buildi - �/- l 1 in &Zonin• Applicant: M,GI..'"r�,iet.l. �lJ�-C �S :'tr Tr-- •.• istrator Project: NE W Cj ` c+ f Y1 ' Public Wo . 1 - . 'ublic Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. ❑Not applicable (Circle one.) Comments: BUILDIN - PLANNING &ZONING Reviewed by: Date: 6/tila TREE ADMIN. Second Review: k Approved as revised. ❑Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: 1/71 Date: 7•//• /(f- FIRE SERVICES Third Review: ❑Approved as revised. Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 1,m- City of Atlantic Beach APPLICATION NUMBER f:1'? , Building Department (To be assigned by the Building Department.) r 800 Seminole Road (c 4l 2 _. _ „ Atlantic Beach, Florida 32233-5445 �t S t p '� ) Phone(904)247-5826 • Fax(904)247-5 Y 3 1,413S�3 // p -art �� E-mail: building-dept@coab.us i Date routed: ✓t/ (/! C City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: t 14 Jackson Rid p ment review required Yes No Buildi Applicant: M,CtkietA. eT, J,-L kcien ing &Zonin_. � Tr " istrator Project: Ne W l b skt Public Wo Public Utiliti& Public Safety Fire Services Review fee $ Dept Signraq,r ak Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ['Denied. [Not applicable (Circle one.) Comments: BUILDING Fkku4s -1-bo 1ary,-h Cares-Prlif PLANNING &ZONING � Reviewed by;�—.J�� ?''` Date:f�/"��� TREE ADMIN. Second Review: Approved as revised. ['Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 f�.Ly f! :,3 Comp. By: S/W Date: 6/4/2018 tJi3 �`' Public Works Department City of Atlantic Beach Permit No: RES 18-0192 Address: 114 Jackson Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth (9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area (A) = 3,906 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft) "C" Wtd "C" Impervious 1,024 3,906 1.00 0.26 Pervious 2,882 3,906 0.20 0.15 Runoff Coefficient(C)= 0.41 Runoff Volume V= 0.41 x 3,906 x 9.3 / 12 V= 1,240 ft3 Postdevelopment Runoff Volume: Lot Area(A) = 3,906 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft2) "C" Wtd"C" Impervious 1,797 3,906 1.00 0.46 %ISA= 46.0% Pervious 2,109 3,906 0.20 0.11 Runoff Coefficient(C)= 0.57 Runoff Volume V= 0.57 x 3,906 x 9.3 / 12 V= 1,720 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume-Predevelopment Runoff Volume DV= 1,720 - 1,240 DV= 479 ft3 Retention Jackson Road 110 6/4/2018 fS r Comp. By: S/W � Date: 6/4/2018 —rdit JO' Public Works Department City of Atlantic Beach Permit No: RES 18-0192 Address: 114 Jackson Provided Storage: Elevation Area Storage (ft) (ft) (ft3) 8.5 215 0 BOTTOM size 39.25 X 5.5 9.0 275 123 TOB size 40.75 X 6.75 Elevation Area Storage (ft) (ft) (ft3) 0.0 0 0 BOTTOM 0.0 0 0 TOB Elevation Area Storage (ft) (ft) (ft3) 0.0 0 0 BOTTOM 0.0 0 0 TOB Inground storage=A*d*pf A=Area= 275.0 d=depth to ESHWT= 5.5 pf=pore factor= 0.3 Inground Storage= 453.8 ft3 Required Treatment Volume= 479 ft3 Supplied Treatment Volume= 576 ft3 Retention Jackson Road 110 6/4/2018 {( /I- REVOCABLE ENCROACHMENT AGREEMENT / /4! a e ksa/1 id• /9-0, d,,/-/. 323 REVOCABLE ENCROACHMENT AGREEMENT by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under tJ a laws of the State of Florida,hereinafter referred to as"CITY"and V. 1l)c U f1 (li 7 f ,t of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. II This work is generally described as (1 e tO co , -t r ,'(N) J`,'")e‘/6 -661/LA I D Me S Any facility maintained, repaired, erected, and/or installed in the exercise of the pnilege granted Mmains subject to relocation or removal on thirty(30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested,to the following address /7.3 g Se,I ucs /1avWyl0,"Aft- Rt/a/tf,c az 7/. ,,�� 3. • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described easement or property of the CITY,the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining,repairing,operating,replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the pennit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of easements,public right- of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. ' / /-- p d V • 6t1G/vat gvi ki. Date - / -ilk Property Owner/Agent(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL z90 The foregoing instrument was acknowledged this day of ,20 / by • R (k Ste/\ J—O C5(...,541-\.___. ,who pe lly appeared before me and stinted na , - t Sit er) C ac°1' ' ledged th. he/s e si 9 ed the in trument voluntarily for the purpose expressed in it. 41) e I Signature of Notary Public,State o Flori Department Approval: Personally Known Produced Identification(Type) ;°:t"' • SPERGER ?*; MY COMMISSION f!FF 924951 �����/� ;- - R EXPIRES:Octobers,2019 colt illiams,Pu, is o Director/ ,,w, °`� Bonded Mrs Notary Public Underwriters Kayle Moore,Public Utilities Director H:\Master Forms\Public-Utilities Works Forms\Revocable Encroachment Agreement . . 8.docx Revision Date:2/5/18 r ,.5-• rS��1Plrin „„ 'fi:nsn RIGHT-OF-WAY/ EASEMENT PERMIT 4Oi=,f- Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINIING UTILITY LOCATES Job Address I/ 4 . 1 C k S oA �� . Phone `7611— 11¢ c.5 7 9 7— .--- Permittee — Permittee r I 1 l o . I-1 -‘_ Aid Email Requesting Permission to Construct le._ —Co,M l ��1 G��dc Ld\ V __ Location(Reference to Cross-Street) .4a, 1'S r/yl 1?C1 M d il p (--"Pa At 15 Ate • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of '...0t, T-.1 /\ b...Dr. (Project Superintendent) with Company Name 1"1Q 1 eft_ < Phone 9 Q c4 —. S (3 3 6 Lo 1 • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be notified twenty-four(24)hours prior to starting work and again immediately upon completion„-- V- (1-A IV\ 4) 16( 't' \ Date_LT-- Q Permittee(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing in trument was acknowle ed this ay of ,20 C 8, by & `Ls Or 0 m ,wh er nally appeared before me and (printed name of Permittee) 1, ac' • edged .he/•,e signed t e instrument voluntarily for the purpose expressed in it. I • �_ OA Personally Known g ature of Notary 'ubli ,State of FF. ida Produced Identification(Type) FTONI GINDIESPERGER MY COMMISSION*FF 924951 • . :Q° EXPIRES:October 6,2019 ,igote Bonded Thru Notary Pubic Underwriters OFFICE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JACKSON STREET TOWNHOUSES LEFT SIDE Builder Name: Marco Heating&Air Inc Street: /if' 4&JACKSON ROAD Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH, FL,32233 Permit Number: Owner: MATHIEU BUILDERS Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2340.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame Wood,Exterior R=19.0 2106.00 ft2 b. Frame-Wood,Adjacent R=11.0 234.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (937.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 797.00 ft2 6. Conditioned floor area above grade(ft2) 1641 b.Under Attic(Vented) R=19.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(192.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 328 a. U-Factor: Dbl,U=0.32 152.00 ft2 SHGC: SHGC=0.29 b. U-Factor: Dbl,U=0.62 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 28.4 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.4 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.282 14.Hot water systems 8. Floor Types (1661.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.999 a.Floor Over Other Space R=13.0 704.00 ft2 b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 704.00 ft2 None c.other(see details) R= 253.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 45.69 Glass/Floor Area: 0.117 PASS Total Baseline Loads: 52.46 I hereby certify that the plans and specifications covered by Review of the plans and 0.''•SHE sTq this calculation are in compliance with the Florida Energy specifications covered by this s,�, ;';FOS Dpaeq donee by Dorothy Deane '� ,,/y�y\/de. DN.CN•Derthy Deane.D•U6.DU='Meroo Heeling aa,,Inc'.D= calculation indicates compliance `•`44, �,,, ' ' =.����.�•. �'•; V o rot h U Deane MUW Heahna 6 Nr,Inc. E=dol®noroi mpervesoom _J �•m 6n!•ulhw of 6.e Eoa,meM Locabon with the Florida Energy Code. ,,,„ •.`. z=....,„.t.,,,,O.�eee t Date:2016-02-0016'.36'.22 --.---11.3* l � ... r i PREPARED Y: Before construction is completed ems_ DATE: �2�///_d - this buildingwill be inspected for :ix ' • -J` v• j compliance with Section 553.908 .'••, bsso,° 4 I hereby certify that this building, as designed, is in compliance Florida Statutes. ..**A'''....„ :Y. .•'�,.:' with the Florida Energy Cod COp •�J.: OWNER/AG NT• _� �� BUILDING OFFICIAL: ni DATE: .S z.3 DATE: 6 .3` ao r b - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: JACKSON STREET TOWNH Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1641 Lot# Owner Name: MATHIEU BUILDERS Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Marco Heating&Air Inc Rotate Angle: 0 Street: ill 1.203 JACKSON ROAD Permit Office: DUVAL CNTY Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH, Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE V Design Location TMY Site Design Temp Int Design Temp Heating Design Daily Temp 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Entire House 1641 14769 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MAIN 704 6336 Yes 0 1 Yes Yes Yes 2 BEDS 937 8433 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge lnsulatio MAIN 94 ft 0 704 ft2 ____ 0.2 0.2 0.6 2 Floor over Garage BEDS ____ ____ 253 ft2 13 0.2 0.2 0.6 3 Floor Over Other Space BEDS ____ ____ 704 ft2 13 0.2 0.2 0.6 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1085 ft2 0 ft2 Medium 0.9 No 0.9 No 0 30.3 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 937 ft2 N N 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDS 30 Blown 797 ft2 0.1 Wood 2 Under Attic(Vented) BEDS 19 Blown 140 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Omt To Wail Type SPac'e -_R-Value.. EL_1n-- Ft_-1n. - Area _--R-_Vacua Fraction -Absor. Grade% 1 N Exterior Frame-Wood MAIN 19 20 0 9 0 180.0 ft2 0 0.23 0.01 0 2 W Exterior Frame-Wood MAIN 19 40 0 9 0 360.0 ft2 0 0.23 0.01 0 3 S Exterior Frame-Wood MAIN 19 7 0 9 0 63.0 ft2 0 0.23 0.01 0 4 E Exterior Frame-Wood MAIN 19 27 0 9 0 243.0 ft2 0 0.23 0.01 0 5 S Garage Frame-Wood MAIN 11 13 0 9 0 117.0 ft2 0 0.23 0.01 0 6 E Garage Frame-Wood MAIN 11 13 0 9 0 117.0 ft2 0 0.23 0.01 0 7 N Exterior Frame-Wood BEDS 19 20 0 9 0 180.0 ft2 0 0.23 0.01 0 8 W Exterior Frame-Wood BEDS 19 50 0 9 0 450.0 ft2 0 0.23 0.01 0 9 S Exterior Frame-Wood BEDS 19 20 0 9 0 180.0 ft2 0 0.23 0.01 0 _10 E Exterior Frame-Wood BEDS 19 50 0 9 0 450.0 ft2 0 0.23 0.01 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood MAIN None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.62 0.25 N 40.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 2 N 1 Vinyl Low-E Double Yes 0.32 0.29 N 30.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 3 W 2 Vinyl Low-E Double Yes 0.32 0.29 N 30.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 4 E 4 Vinyl Low-E Double Yes 0.32 0.29 N 6.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 5 N 7 Vinyl Low-E Double Yes 0.32 0.29 N 9.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 6 W 8 Vinyl Low-E Double Yes 0.32 0.29 N 12.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 7 W 8 Vinyl Low-E Double Yes 0.32 0.29 N 45.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 8 S 9 Vinyl Low-E Double Yes 0.32 0.29 N 20.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 GARAGE V # Floor Area - Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 307.8 ft2 307.8 ft2 50 ft 8 ft 1 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INFILTRATION # Scope Method SLA CFM 50 ELA EgIA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1723.1 94.59 177.9 .3795 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 28.4 kBtu/hr 1 sys#1 COOLING SYSTEM _ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.999 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS V ----Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 328 ft2 Attic 82 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingH Jan Feb Mar A r [ ]Ma [X]Jun X Jul X AuguX]Se Oct Nov Dec HeatinJan ;XJ Feb X Mar Apr ]Ma [ ]JunJulfAu [ ]Sep OctXJNovXDecVentin Jan Feb X Mar V Apr [ ]May [ ]Jun Jul [ Aug [ iSep X Oct X Nov Dec 2/7/2018 2:09 PM EnergyGauge8 USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. I! 'f' t20 JACKSON ROAD, ATLANTIC BEACH, FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 2106.00 ft2 b. Frame-Wood,Adjacent R=11.0 234.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? 10.Ceiling Types Insulation Area No a.Under Attic(Vented) R=30.0 797.00 ft2 6. Conditioned floor area(ft2) 1641 b.Under Attic(Vented) R=19.0 140.00 ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.32 152.00 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 328 SHGC: SHGC=0.29 b. U-Factor: Dbl,U=0.62 40.00 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 28.4 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 28.4 HSPF:8.50 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.282 8. Floor Types Insulation Area 14.Hot water systems a.Floor Over Other Space R=13.0 704.00 ft2 a. Electric Cap:50 gallons EF: 1 b.Slab-On-Grade Edge Insulation R=0.0 704.00 ft2 c.other(see details) R= 253.00 ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building SHE sr Construction through the above energy saving features which will be installed (or exceeded) •:.'�,��`.-r...;.....•.'�TFo :. in this home before final inspection. Otherwise, a new EPL Display Card will be completed //,,,,A,';,'.....'- - ;��,,:�-,,n based on installed Code compliant features. . '� ':�;.e",gyp' Builder Signature: Date: SA. /1 0 c City/FL . Address of New Home: 11��u,Es„� gy Ie.., • vy � ... oDw- •32e31 `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: ))4-4JACKSON ROAD Permit Number: ATLANTIC BEACH, FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory).The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6. Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakagdndows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or HAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5 • MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts. air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f), (g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5 • MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential,or Florida Building Code.Mechanical,as applicable,or with other approved means of ventilation including: Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5 • MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches.Time switches or other control methods that can automatically tum off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatorylie energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory)Fuel gas lighting systems shall not have continuously buming pilot lights. 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 5 of 5 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: JACKSON STREET TOWNHOUSES LEFT SIDE Builder Name: Marco Heating&Air Inc Street: l&JACKSON ROAD Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number: Owner: MATHIEU BUILDERS Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shalt be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind pining and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 • FORM R405-2017 Envelope Leakage Test Report Performance • FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: JACKSON STREET TOWNHOUSES LEFT SIDE Builder Name: Marco Heating&Air Inc Street: i i f 12G JACKSON ROAD Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH, FL, 32233 Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 1641 sq.ft. Cond.Volume: 14769 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: FORM R405-2017 1 Pa cfm 2 Pa cfm Tested ACH(50) * : 3 Pa cfm ' *Tested leakage must be less than or equal to the 4 Pa cfm required ACH(50)shown on Form R405-2017 for 5 Pa cfm this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation 6 Pa cfm system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either • ov.'-ME STgTE'• performance results demonstrate compliance individuals as defined in Section • ti, , • - •• ...0., with Florida Energy Code requirements in 553.993(5) or(7), Florida Statutes or ''y ° . = 4 i individuals licensed as set forth in ,°u :`..�''•• ,:0 : accordance with Section R402.4.1.2. Asim,! .7 Section 489.105(3)(f), (g), or(i)or an ;74 "'v.+._-;C. approved third party. A written report of :V �. ;a? �� the results of the test shall be signed ao�° ` •. SIGNATOR �� by the third party conducting the test �...iy,.: �r :. � :'� and provided to the code official. COD 1J,,.�. PRINTED NAME: �.- e w� 464 w,•-) / BUILDING OFFICIAL: DATE: 5/L S/ /le / 1t DATE: 2/7/2018 2:09 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 BuildingAnalysis Job: JACKSON STREET TOWN... wrightsoft y Date: FEB 7,2018 Entire House By: MARCO HEATING AND AIR Plan: CUSTOM Marco Heating & Air Inc 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 Pro'ect Information For: JACKSON STREET TOWNHOUSE LEFT SIDE, MATHIEU BUILDERS i)4- +243-JACKSON RD,ATLANTIC BEACH, FL 32233 Phone: 904-268-2845 Desi• n Conditions Location: Indoor: Heating Cooling Jacksonville Intl AP, FL, US Indoor temperature(°F) 70 75 Elevation: 33 ft Design TD (°F) 38 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 11.0 51.2 Dry bulb(°F) 33 93 Infiltration: Daily range(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 2.6 5625 24.9 Glazing 14.4 2759 12.2 Vs acts Doors 14.6 307 1.4 Ceilings 1.2 1124 5.0 Floors 4.6 4331 19.2 Infiltration 1.8 3854 17.1 Ducts 4563 20.2 t Piping 0 0 Humidification 0 0 � Ventilation 0 0 Adjustments 0 Total 22563 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 1.4 3042 14.3 Glazing 25.6 4913 23.0 V�IIs Irtinfiraial eria40E1ns Doors 11.8 247 1.2 Ceilings 1.7 1610 7.5 Floors 0.1 81 0.4 Infiltration 0.5 957 4.5 Gaang. Ducts 6259 29.3 Ventilation 0 0 Internal gains 4220 19.8 p Blowerrts 0 0 Adjustments 0 %Lim Total 21329 100.0 Latent Cooling Load=6479 Btuh Overall U-value=0.091 Btuh/ft2-°F Data entries checked. wrightsoft 2018-Feb-07 14:17:54 Right-Suite®Universal 2018 18.0.08 RSU17889 Page 1 AC ...ACKSON ROAD\LEFT SIDE JACKSON RD RIGHT SIDE.rup Calc=MJ8 Front Door faces: S Project SummaryJob: JACKSON STREET TOWN... wrightsoftDate: FEB 7,2018 Entire House By: MARCO HEATING AND AIR Marco Heating & Air Inc Plan: CUSTOM 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License CAC1815711 Pro.ect Information For: JACKSON STREET TOWNHOUSE LEFT SIDE, MATHIEU BUILDERS II 4_42fl JACKSON RD,ATLANTIC BEACH, FL 32233 Phone: 904-268-2845 Notes: ORIENTATION-S-FRONT DOOR 2.5 TON 5KW Desi•n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 51 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18000 Btuh Structure 15070 Btuh Ducts 4563 Btuh Ducts 6259 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22563 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21329 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5011 Btuh Ducts 1468 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1641 1641 Equipment latent load 6479 Btuh Volume (ft') 14769 14769 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 27808 Btuh Equiv. AVF (cfm) 94 49 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg Make Goodman Mfg. Trade GOODMAN; JANITROL; AMANA DISTI... Trade GOODMAN; JANITROL; AMANA DISTI... Model GSZ140301 K Cond GSZ140301 K AHRI ref 8242621 Coil ASPT37C14A AHRI ref 8242621 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 19880 Btuh Heating output 28000 Btuh @ 47°F Latent cooling 8520 Btuh Temperature rise 27 °F Total cooling 28400 Btuh Actual air flow 947 cfm Actual air flow 947 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.77 Capacity balance point=29°F Backup: Input=6 kW, Output=22146 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. lay ri httsott 2018-Feb-0714:17:55 Right-Suite®Universal 2018 18.0.08 RSU17889 Page 1 /Y.C.A ...ACKSON ROAD\LEFT SIDE\JACKSON RD RIGHT SIDE.nrp Calc=MJ8 Front Door faces. S + wrightsoft Right-J® Worksheet Job: JACKSON STREET TOWNHO... Entire House Date: FEB 7,zo,s By: MARCO HEATING AND AIR Marco Heating &Air Inc Plan: CUSTOM 720 Mill Creek Rd.Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 1 Room name Entire House MAIN 2 Exposed wall 234.0 ft 94.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 704.0 ft 5 Room area 1641.0 ft' 704.0 ft' - r -- - -T-- - - ---T- - - t--- - - - - - - -� - Ty Construction U-value Or HTM Area (f t') Load Area (ft') Load number (Btuh/f t'-°F (Btuh/f l') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) _]. Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat ! Cool 6 VJ 12E-Osw 0.068 n 2.55 1.43 360 281 716 403 180 110 280 158 . -G 1D-c2om 0.320 n 12.00 10.51 9 0 108 95 0 0 0 0 . -G 4A5-2omd 0.620 n 23.25 14.54 40 0 935 585 40 0 935 585 -G 4A5-2ov 0.320 n 12.00 10.51 30 0 360 315 30 0 360 315 11 Vel 12E-Osw 0.068 e 2.55 1.43 693 687 1752 986 243 237 604 340 l_ G 4A5-2ov 0.320 e 12.00 30.13 6 0 72 181 6 0 72 181 T___i0 12E-Osw 0.068 s 2.55 1.43 243 202 515 290 63 42 107 60 1D-c2om 0.320 s 12.00 10.51 20 20 240 210 0 0 0 0 11D0 0.390 s 14.62 11.78 21 21 307 247 21 21 307 247 W 12E-Osw 0.068 w 2.55 1.43 810 723 1844 1037 360 330 842 473 -G 1D-c2om 0.320 w 12.00 30.13 12 0 144 362 0 0 0 0 -G 1 D-c2om 0.320 w 12.00 30.13 45 0 540 1356 0 0 0 0 -0 4A5-2ov 0.320 w 12.00 30.13 30 0 360 904 30 0 360 904 P 12C-Osw 0.091 - 3.41 1.39 234 234 799 326 234 234 799 326 C 16B-30ad 0.032 - 1.20 1.72 937 937 1124 1610 0 0 0 0 F 19A-13bscp 0.065 - 1.78 0.84 20 20 36 17 0 0 0 0 F 19C-19cscp 0.049 - 0.64 0.30 213 213 136 64 0 0 0 0 F 22A-tpm 1.180 - 44.25 0.00 704 94 4159 0 704 94 4159 0 6 c)AED excursion I 906 151 Envelope loss/gain I{ 14146 9893 { 8825 3740 12 a) Infiltration 3854 957 1548 385 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 3300 2400 Subtotal(lines 6 to 13) 18000 15070 10373 6524 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18000 15070 10373 6524 15 Duct loads 25% 42% 4563 6259 25% 42% 2630 2710 2341 1 Air al roomrequii dl(c m) I oad22947 56321329 I I 130461 029410 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -r{+ w..yt'. c.f tst 2018-Feb-07 14:17:55 Right-Suite®Universal 2018 18.0.08 RSU17889 Page 1 4:.(71. ...ACKSON ROAD\LEFT SIDE\JACKSON RD RIGHT SIDE.rup Calc=MJ8 Front Door faces: S 4 wrightsoft Right-J® Worksheet Job: JACKSON STREET TOWNHO... Entire House Date: FEB 7,2018 By: MARCO HEATING AND AIR Marco Heating & Air Inc Plan: CUSTOM 720 Mill Creek Rd.Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 1 Room name BEDS 2 Exposed wall 140.0 ft 3 Room height 9.0 ft heat/cool 4 Room dimensions 1.0 x 937.0 ft 5 Room area 937.0 ft' I r i i Ty Construction U-value Or HTM Area (ft') Load I Area Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter 1 Heat 1 Cool Gross 1 N/P/S Heat I Cool 1 Gross I N/P/S Heat 1 Cool 6 VJ 12E-Osw 0.068 n 2.55 1.43 180 171 436 245 . ---G 1D-c2om 0.320 n 12.00 10.51 9 0 108 95 . -G 4A5-2omd 0.620 n 23.25 14.54 0 0 0 0 -G 4A5-2ov 0.320 n 12.00 10.51 0 0 0 0 11 Vt! 12E-Osw 0.068 e 2.55 1.43 450 450 1148 646 C, 4A5-2ov 0.320 e 12.00 30.13 0 0 0 0 12E-Osw 0.068 s 2.55 1.43 180 160 408 230 1D-c2om 0.320 s 12.00 10.51 20 20 240 210 D 11D0 0.390 s 14.62 11.78 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 450 393 1002 564 1D-c2om 0.320 w 12.00 30.13 12 0 144 362 1D-c2om 0.320 w 12.00 30.13 45 0 540 1356 4A5-2ov 0.320 w 12.00 30.13 0 0 0 0 P 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 937 937 1124 1610 F 19A-13bscp 0.065 - 1.78 0.84 20 20 36 17 F 19C-19csco 0.049 - 0.64 0.30 213 213 136 64 F 22A-tpm 1.180 - 44.25 0.00 0 0 0 0 6 c)AED excursion 755 Envelope loss/gain 5321 6153 { 12 a) Infiltration 2306 573 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 4 920 Appliances/other 900 Subtotal(lines 6 to 13) 7627 8546 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 7627 8546 15 Duct loads 25% 42% 1933 3549 1 Totalrequireroomd load(cfm) 1 1 95611 120951 Air 4011 537 J l Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4. w•.yi.t .tt 2018-Feb-07 14:17:55 h A Right-Suite®Universal 2018 18.0.08 RSU17889 Page 2 .ACKSON ROAD\LEFT SIDE\JACKSON RD RIGHT SIDE.rup Calc=MJ8 Front Door faces. S Manual S Compliance Report Job: JACKSON STREETTON... + �- wrightsoft WDate: FEB 7,2018 Entire House By: MARCO HEATING AND AIR Marco Heating & Air Inc Plan: CUSTOM 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 Project Information For: JACKSON STREET TOWNHOUSE LEFT SIDE, MATHIEU BUILDERS it - JACKSON RD,ATLANTIC BEACH, FL 32233 Phone: 904-268-2845 Cooling Equipment Design Conditions Outdoor design DB: 92.7°F Sensible gain: 21329 Btuh Entering coil DB: 77.9°F Outdoor design WB: 77.1°F Latent gain: 6479 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 27808 Btuh Indoor RH: 50% Estimated airflow: 947 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman Mfg. Model: GSZ140301K+ASPT37C14A Actual airflow: 947 cfm Sensible capacity: 19880 Btuh 93%of load Latent capacity: 8520 Btuh 132%of load Total capacity: 28400 Btuh 102%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 22563 Btuh Entering coil DB: 68.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman Mfg. Model: GSZ140301 K+ASPT37C14A Actual airflow: 947 cfm Output capacity: 28000 Btuh 124%of load Capacity balance: 29 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 947 cfm Output capacity: 6.5 kW 98%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. wrightsoft 2018-Feb-0714:17:55 Right-Suite®Universal 2018 18.0.08 RSU17889 Page 1 AZ ...ACKSON ROAD\LEFT SIDE\JACKSON RD RIGHT SIDE.rup Calc=MJ8 Front Door faces: S 1 �: ,E 3�C I - Mw0. l 0 �1 V ,c),, I ^'�^'' ® 0j z i _L i I �, I I 1 $ --4 Il spy � � �' :7.3. 14. t-0. �J I pl j; l �, -�► > 8. 3, 4111 • I Y II.. L I 1 1 z-:.`l: pt' ..4. 1 f. 1 ft. :' fij s' ' I • , .1/2. *I I • ),'a, e. 11-f. I •.....1 .,a krik jks f i caoerx+ r . I I { Yl I 21d-- I I d 3. - I _as. ,-- Q iliilar I , I - - 4 ; iiik eil;. 14,-i, 17 I •"----,, rit Y117u; i i -F -- -I - LI 1I Ir 1 _I-- ---- T \ .,.„......„., I I —sEZ ` ' L --- Oa M2d:1� ecQ-bYriR 1 MATHIEU BUILDERS PLAN: TOWNHOUSE LOT#: LEFT SIDE SUBDIVISION: JACKSON ROAD TOWNHOUSE GOODMAN 2.5 TON HEAT PUMP SYSTEM SEER: 15 HSPF: 8.5 DESIGN COOL BTUH: 30000 AVAILABLE STATIC PRESSURE: 1:1 TOTAL CFM: 1235 TOTAL EFFECTIVE LENGTH: 219 PERFORMANCE METHOD: DUCT MATERIAL: R6 VINYL FLEX SUPPLY BRANCH DETAIL TABLE ROOM NAME COOLING CFM BRANCH SIZE LINEAR FT DUCT MATERIAL POWDER 35 CFM 4" 19' VINYL FLEX DINING 200 CFM 8" 8' VINYL FLEX LIVING 200 CFM 8" 12' VINYL FLEX KITCHEN 165 CFM 7" 18' VINYL FLEX LAUNDRY 35 CFM 4" 16' VINYL FLEX PANTRY 35 CFM 4" 18' VINYL FLEX BR3 165 CFM 7" 12' VINYL FLEX BATH 2 (2) 35 CFM (2) 4" 18' VINYL FLEX BR2 165 CFM 7" 8' VINYL FLEX BR2 WIC 35 CFM 4" 15' VINYL FLEX MBR 200 CFM 8" 20' VINYL FLEX MBA 35 CFM 4" 16' VINYL FLEX MBR WIC 35 CFM 4" 15' VINYL FLEX MBA TOILET 35 CFM 4" 24' VINYL FLEX TOTALS 1235 CFM 219 LN (FT) SUPPLY TRUNK DETAIL TABLE LOCATION DESIGN BTUH TRUNK SIZE DUCT MATERIAL FROM UNIT TO 1ST DISTR BOX 12202 10" VINYL FLEX FROM UNIT TO 1ST DISTR BOX 21054 14" VINYL FLEX 1