Loading...
1841 ATLANTIC BEACH DR - REVISION 7/23/18 1-4 CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date 7/23/2018 Revision to Issued Permit X Corrections to Comments Permit# RES18-0038 Project Address 1841 Atlantic Beach Drive Contractor/Contact Name Audrey Regnier Phone 904.595.5243 Email aregnier@tollbrothers.com Description of Proposed Revision/Corrections: Permit Fee Du, $ 5O.0D Revised ecalcs Additional Increase in Building Value $ Additional S.F. Bysigningbelow, , Audrey Regnier affirm the Revision is inclusive of the proposed changes. (printed name) • IOUtejirri ° 7/23/2018 Signature of C tractor/Agent( nCY tractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review CommentsLOa'/ Tito n. if, vi Sed S 1 Car 13 fa/rP-� Department Review Required: Building Y ' Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities F- 6 - L Public Safety Date Fire Services 5"-/-a 74. G--I' rLOi'-i ' Q FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Franklin 3448 Left SW Builder Name: Toll Brothers , I Street: Lot 48 ABCC Permit Office: Duval City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3611.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=19.0 3422.00 ft2 b.Frame-Wood,Adjacent R=13.0 189.00 ft2 3. Number of units,if multiple family 1 • c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No -10.Ceiling Types (1729.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 3448 b.Under Attic(Vented) R=19.0 188.00 ft2 Conditioned floor-area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(596.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 644 a. U-Factor: Dbl,U=0.34 596.17 ft2 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 '12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 48.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: • 13.Heating systems kBtu/hr Efficiency . d. U-Factor: N/A ft2 a.Electric Heat Pump 48.0 HSPF:8.20 • SHGC: . • Area Weighted Average Overhang Depth: 4.665 ft. Area Weighted Average SHGC: 0.270 14.Hot water systems 8. FloorTypes (3448.0 sqft.) Insulation Area a.Natural Gas Tankless Cap: 1 gallons EF:0.800 . - a.Slab-On-Grade Edge Insulation R=0.0 1719.00 ft2 b. Conservation features l- b. b.Floor Over Other Space R=0.0 1351.00 ft2 None c.other(see details) R= 378.00 ft215.Credits Pstat Glass/Floor Area: 0.173 Total Proposed Modified Loads: 79.19 PASS • . Total Baseline Loads: 91.17 /� , I hereby certify that the plans and specifications covered by Review of the plans and ��,r'`. oiESxq? , this calculation are in compliance with the Florida Energy specifications covered by this +`.ti.-•";r ;*_ �..,0`N Code. calculation indicates compliance f ca i�i, /(14r I,---1. .'4',,A. . with the Florida Energy Code. , �r . ,..•,C' y` PREPARED BY: =*� U 4t.-9jE /0-i /44 c Before construction is completed 4 r�' tzv;` -c.�i.' '•-4�. DATE: ,72-O7 'Z cY7. this building will be inspected for .0 i,�l ,,. compliance with Section 553.908 ,;la• i a • Florida Statutes. v I hereby certify that this building,as designed, is in compliance ��?4�4,• • -..-•cam o with the Florida Ener.y)Code. w �` q WA V ,+�''�� OWNER/A ENT: �:v.. -/ci ' • -- BUILDING OFFICIAL: ^�, DATE: .'?�j/1' 'DATE: / - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1:1 and an envelope leakage • test report in accordance with R402.4.1.2. REVISION ISION BP# LES I k-00-K6 _ 12/7/2017 6:06 PM DATE -E/herg&au ®t/SriaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 SIGNED 'k i FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method i Project Name: Franklin 3448 Left SW Builder Name: Toll Brothers Street: Lot 48 ABCC Permit Office: Duval City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3611.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3422.00 ft2 b.Frame-Wood,Adjacent R=13.0 189.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1729.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 3448 b.Under Attic(Vented) R=19.0 188.00 ft2 Conditioned floor•area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(596.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 644 a. U-Factor. Dbl,U=0.34 596.17 ft2 SHGC: SHGC=0.27 b. U-Factor. N/A ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 48.0 SEER:14.00 SHGC: c. U-Factor. N/A -ft2 SHGC: 13.Heating systems kBtu/hr Efficiency . d. U-Factor: N/A ft2 a.Electric Heat Pump 48.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.665 ft. Area Weighted Average SHGC: 0.270 - 14.Hot water systems a.Natural Gas Tankless Cap: 1 gallons 8. FloorTypes (3448.0 sqft.) Insulation Area • EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 1719.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1351.00 ft2 None c.other(see details) R= 378.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 79.19 - Glass/Floor Area: 0.173 PASS Total Baseline Loads: 91.17 I hereby certify that the plans and specifications covered by . Review of the plans and `,+,.of.GK E.Sz4� ',;�+ this calculation are in compliance with the Florida Energy specifications covered by this ti•; :,.._ „ D, Code. calculation indicates compliance ;.ca �r„��'1..1-s-�`�4.��`:+ ., c with the Florida Energy Code. f�.oak:' �,' } ��„ D7s; PREPARED BY:G% - -~"C.At-2 ‘u/n uvac Before construction is completed • _ . d DATE: /2-d7 Z- '7 this building will be inspected for 1 C3•, , l ;,Z, compliance with Section 553.908 •. n . Florida Statutes. �t " �'` '� I hereby certify that this building,as designed,is in compliance \..q°01:).- ,tiC ' with the Florida Energy Code. /y� 'q��,0D,� 0. OWNER/AGENT: BUILDING OFFICIAL: / DATE: DATE: k-6' /,r - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2;1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. OFFICE COPY REVISION • ,, r •-• 0,,�, m017 12/ -••- - •yGaugee USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 DATE . 11,% SIGNED FORM R405-2014 PROJECT Title: Franklin 3448 Left SW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3448 Lot# Owner: Toll Brothers Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: Lot 48 ABCC Permit Office: Duval Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design DailyTemp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 3448 32751 SPACES Number Name Area Volume Kitchen Occupants Bedrooms [nth ID Finished Cooled Heated 1 Main 1719 17190 Yes 1 1 1 Yes Yes Yes 2 .2nd Floor 1729 15561 No -4 3 1 Yes Yes Yes FLOORS VFloor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 167 ft 0 1719 ft2 —_ 0 0 1 • • 2 Floor over Garage 2nd Floor ___ 378 ft2 19 0 0 1 3 Floor Over Other Space 2nd Floor —_ 1351 ft2 0 0 0 1 • ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1873 ft2 360 ft2 Medium 0.4 N 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1729 ft2 N N 12/7/2017 6:06 PM EnergyGauge®USA-FiaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING . V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 38 Blown 1541 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 19 Blown 188 ft2 0.11 Wood WALLS `/ Adjacent Cavity Width Height Sheathing Framing Solar Below V # Omt To Wall Type Space R-Value Ft In Ft in Area R-Value Fraction Ahcor Grade% _'1 SW Exterior Frame-Wood 2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 2 SW Exterior Frame-Wood Main 19 19 0 10 0 190.0 ft2 0 0.23 0.6 0 3 SE Exterior Frame-Wood 2nd Floor 19 54 0 9 0 486.0 ft2 0 0.23 0.6 0 4 SE Exterior Frame-Wood Main 19 54 0 10 0 540.0 ft2 0 0.23 0.6 0 5 NE Exterior Frame-Wood 2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 6 NE Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.6 0 , 7 NW Exterior Frame-Wood 2nd Floor 19 54 0 9 0 486.0 ft2 0 0.23 0.6 0 _ 8 NW Exterior Frame-Wood Main 19 54 0 10 .0 540.0 ft2 0 0.23 0.6 0 9 SW Garage Frame-Wood Main 13 21 0 9 0 189.0 ft2 0 0.23 0.01 0 10 N Exterior Frame-Wood Main 19 3 0 10 0 30.0 ft2 0 0.23 0.6 0 11 E Exterior Frame-Wood Main 19 3 0 10 0 30.0 ft2 0 0.23 0.6 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated Main None .4 3 8 24 ft2 2 SW Wood Main None .4 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V -# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening " 1 SW 1 Vinyl Low-E Double Yes 0.34 0.27 8.0 ft2 7 ft 4 in 1 ft 0 in None Exterior 5 . 2 SW 1 Vinyl Low-E Double Yes 0.34 0.27 8.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 3 SW '1 Vinyl Low-E Double Yes 0.34 0.27 33.3 ft2 7 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 4 SW '1 Vinyl Low-E Double Yes 0.34 0.27 5.3 ft2 7 ft 4 In 1 ft 0 In Drapes/blinds Exterior 5 5 SW 2 Vinyl Low-E Double Yes 0.34 0.27 36.0 ft2 7 ft 4 in 1 ft 0 In None Exterior 5 6 SE 3 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 • 7 SE 3 Vinyl Low-E Double Yes 0.34 0.27 40.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 8 SE 4 Vinyl Low-E Double Yes 0.34 0.27 60.0 ft2 1.ft 4 in 1 ft 0 in None Exterior 5 9 NE 5 Vinyl Low-E Double Yes 0.34 0.27 60.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 10 NE 6 Vinyl Low-E Double Yes 0.34 0.27 96.0 ft2 10 ft 4 in '1 ft 0 In None Exterior 5 11 NE 6 Vinyl Low-E Double Yes 0.34 0.27 18.0 ft2 10 ft 4 in 1 ft 0 in None Exterior 5 12 NE 6 Vinyl Low-E Double Yes 0.34 0.27 12.0 ft2 10 ft 4 in 1 ft 0 in None Exterior 5 13 NW 7 Vinyl Low-E Double Yes 0.34 0.27 2.5 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 14 NW 7. Vinyl Low-E Double Yes 0.34 0.27 22.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 15 NW 8 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 16 NE 6 Vinyl Low-E Double Yes 0.34 0.27 36.0 ft2 10 ft 4 In 1 ft 0 in None Exterior 5 17 SW 1 Vinyl Low-E Double Yes 0.34 0.27 5.3 ft2 7 ft 4 In 1 ft 0 in None Exterior 5 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. i, / Wall Overhang `\/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation• Int Shade Screening 18 NE 5 Vinyl Low-E Double Yes 0.34 0.27 66.7 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 19 SE 4 Vinyl Low-E Double Yes 0.34 0.27 18.0 ft2 1 ft 4 In 1 ft 0 in None Exterior 5 20 N 10 Vinyl Low-E Double Yes 0.34 0.27 12.0 ft' 1 ft 4 in 1 ft 0 in None Exterior 5 21 E 11 Vinyl Low-E Double Yes 0.34 0.27 12.0 ft2 1 ft 4 in '1 ft 0 in None Exterior 5 I I GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation I' 1 523 ft2 523 ft2 53 ft 9 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000422 3820.9 209.76 394.49 .4005 7 HEATING SYSTEM • # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 48 kBtu/hr 1 sys#1 . COOLING SYSTEM V =# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts '1 Central Unit Split SEER:14 48 kBtu/hr 1440 cfm 0.74 1 sys#1 • HOT WATER SYSTEM • V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.8 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM • V FSEC Collector Storage Cert•# Company Name System Model# Collector Model# Area Volume FEF None None ft: DUCTS ' / ---Supply--- —Return--- Air CFM 25 CFM25 HVAC V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 644 ft2 Attic 241 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1 . • 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ Jan Feb [[ Mar Apr May X Jun X Jul X Aug X Sep Oct Nov Dec Venting [X�Jan �X�Feb [X�Mar [X Apr May Jun Jul Aug Sep [X Oct [X Nov tX Dec Venting [[ Jan Feb [[X Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 . 78 78 78 78 78 78 78 PM, 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 • • • 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) . DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. Lot 48 ABCC, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 3422.00 ft' b.Frame-Wood,Adjacent R=13.0 189.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1541.00 ft2 6. Conditioned floor area(ft2) 3448 •b.Under Attic(Vented) R=19.0 188.00 ft2 c.N/A R= ft2 7. Windows" Description Area 11.Ducts R ft2 a. U-Factor. Dbl,U=0.34 596.17 ft2 a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 644 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a.Central Unit 48.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 48.0 HSPF:8.20 Area Weighted Average Overhang Depth: 4.665 ft. Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14.Hot water systems yp a.Natural Gas Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1719.00 ft2EF:0.8 b.Floor Over Other Space R=0.0 1351.00 ft2 b. Conservation features c.other(see details) R= 378.00 ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building `,�,�4 EKE STq'•+" Construction through the above energy saving features which will be installed (or exceeded) >� o T *.'.- in this home before final inspection. Otherwise, a new EPL Display Card will be completed y.„"'%`.? % `=�_ rn based on installed Code compliant features. : t 'nn, ",,, ;.:i ,,,0 c191 ''Y q �. Builder Signature: Date: .4c p 1 • ` 1 Address of New Home: City/FL Zip: Go *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For • information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 . FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Lot 48 ABCC Permit Number: Atlantic Beach,FL, MANDATORY REQUIREMENTS See individual code sections for full details. O 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. • R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4:1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in • accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. • Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and i. 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air Infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. - O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. • R403.1:1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403:1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. o R403:2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section ' 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. - • 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system, including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not Installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have • heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'A inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4:1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls _ capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to-be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed In residential units shall meet the minimum efficiencies of Table C404.2 In Chapter-4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. • O R403.6:1 Equipment sizing. Heating and cooling equipment shall be sized In accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6:1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6:1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1:1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance • with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ▪ solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). • Fuel gas lighting systems shall not have continuously burning pilot lights i ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 FORM R405-2014 , TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Franklin 3448 Left SW Builder Name: Toll Brothers Street: Lot 48 ABCC Permit Office: Duval City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK • Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation . Walls and sill plate shall be sealed. The junction of the top plate and the topor exterior walls shall be sealed. . Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and -./. framing shall be sealed. ,./. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside 7 and cantilevered floors) of subfloor decking. ./'The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. ••J// Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. f Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled J/ by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. / Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be �// air tight, IC rated, and sealed to the drywall. / Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in J/ exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. / Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air •// ! barrier installed separating them from the showers and tubs. / Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or V air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be s-/z7 sealed to the sub-floor or drywall. / Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method • Project Name: Franklin 3448 Left SW Builder Name: Toll Brothers Street: Lot 48 ABCC Permit Office: Duval City,State,Zip: Atlantic Beach,FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 3448 sq.ft. Cond.Volume: 32751 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: I ELA: Eq LA: ACH: ACH(50): SLA: R402.4:1.2 Testing. The building or dwelling unit shall be.tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and • 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, o'o�ocEsT.�x '�.. performance results demonstrate compliance testing shall be conducted by an t.iv. f�' s`a. o'�. with Florida Energy Code requirements in approved third party.A written h '����; ' ° ^�; accordance with Section R402.4.1.2. report of the results of the test shall ; be signed by the third party I a;____ ,,m d; 4.1 conducting the test and provided to ' '� ' *.. ,o. � gip",• SIGNATURE: the code official. :=4{\411111r r .es, . C'ob` . PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 12/7/2017 6:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 tch Project Summary Date; Lot 48 ABCC lailiVai 'rt %z Entire House By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC12... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904) 217-0739 Fax: 904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: Model-Franklin Desi•n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 40216 Btuh Structure 28887 Btuh Ducts 5243 Btuh Ducts 6339 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 45459 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load ( Ifttuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3 (partial)/2 Pressure/AVF 50 Pa/3920 cfm Structure 11184 Btuh Ducts 1151 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 3448 3448 Equipment latent load„ <JS tuh Volume(fP) 33597 33597 Air changes/hour 0.68 0.42 Equipment Total Load(Seri+Lat) _ 270 tuh Equiv.AVF (cfm) 378 237 Req.total capacity at 0.70 SHR 4.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB048 Cond CH14NB048 AHRI ref Coil FB4CNP048 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 32900 Btuh Heating output 46000 Btuh @ 47°F Latent cooling 14100 Btuh Temperature rise 30 °F Total cooling 47000 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.74 Capacity balance point=32°F Backup: Input= 13 kW, Output=45459 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -f - wrlghtsoft'°• 2018-Jul-2309:01:08 ,L`• •-,,,-,- •---•.—•.,-.,-, Comfort Builder by Wrightson 18.0.20.01 RSU12270 Page 1 ACC . ...Brothers\Franklin 3448 Left SW Lot 48 ABCC.rup Calc=MJ8 Front Door faces:SW :J 1'_ 'ew- First Floor "\%. 6 x 10 i 6' kitchen/bkfsl 0x6 familyr 6 MI • 10 x 6 6 x 10 6' 6' 12" 4x8 ;J " Fa 4" bath 3 ■ bed stair! — 10x6 12x12 8 storagr 6" �• P 18x18 14" mud rrc Ret Ri-er �•� 6x10 0/ 14" 6„ 6 x 10 _ p Riser 5" 14 9" di:inc foyer 12" u.... 10x6 111111 GARAGE 4 5 10x6 6" study 0 0 Job #: Lot 48 ABCC McGowan's Heating & Air Conditionin. Scale: 1 . 87 Performed by Saldie Guintivano for: Page 1 Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder byWrightson 160 Cape May Ave. g Ponte Vedra,Fl 32081 Jacksonville,Fl 32256 18.0.20.01 RSU12270 Phone:(904)217-0739 Fax:(904)814-8173 Phone:904-278-0339 Fax:904-278-0366 2018-Jul-23 09:02:21 www.tollbrothers.com smerten@tollbrothersinc.com www.mcgowansac.com saldie@mcgowansac.com ...lin 3448 Left SW Lot 48 ABCC.rup i►_ Afar 2ND FL • 6x12 6x10 t 6' to wig 14"bypass 10 x 6 maste 12" Dampen loft 5" '•' 6x12 10" Damper "M" 6x10 t ! 6" ■ 3" Fan rdre 16x16 1111-J 14" • 10" 12" � ■ I ■ m batt laundr 4 x 8 4 stairs, �� 16" 6x10 6x10 5„ 5" 8x '� 4 r' J WCI 10x10 10x10 9" �.� 16' # 8 10x6lig�� • 5" �J RN Rise 14„ 6 x 10 14 ' 1, 6, mwic: ep 14" 4x8 ! bed up Riser4 18 x 18 14'• 12x12 8x4 Mount 14"damper at r 4" the floor 12 x 12 sink 9" 12x6 7" bed 8x4,,, 4 J bath 2 3" Fan Job #: Lot 4ABCC McGowan's Heating & Air Conditionin. Scale: 1 : 87 Performed by Saldie ie Guintivano for: Paget Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,Fl 32256 18.0.20.01 RSU12270 Ponte Vedra,Fl 32081 Phone:(904)217-0739 Fax:(904)814-8173 Phone:904-278-0339 Fax:904-278-0366 2018-Jul-23 09:02:21 www.mcgowansac.com smerten@tollbrothersinc co n ww mcgowansac.com saldie@mcgowansac.com lin 3448 Left SW Lot 48 ABCC.rup Manual S Compliance Report Date: Lot 48 ABCC Entire House By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC12... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten©tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 35165 Btuh / Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 7535 Btuh , Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 42700 Btuh Indoor RH: 50% Estimated airflow: 1400 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB048+FB4CNP048 Actual airflow: 1400 cfm Sensible capacity: 35706 Btuh 102%of load • Latent capacity: 7550 Btuh 100%of load !/ Total capacity: 43255 Btuh 101%of load SHR: 83% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: •45459 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB048+FB4CNP048 Actual airflow: 1400 cfm Output capacity: 38129 Btuh 84%of load Capacity balance: 32 °F Supplemental heat required: 7330 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1400 cfm Output capacity: 13.3 kW 100%of load Temp. rise: 75 °F Meets all requirements of ACCA Manual S. 41- vtrrlghtsoft- 2018-Jul-23 09:01:08 �,. Comfort Builder by Wrightson 18.0.20.01 RSU12270 Page 1 Brothers\Franklin 3448 Left SW Lot 48 ABCC.rup Calc=MJ8 Front Door faces:SW co Y a m 0 C tnCOC CDIl) CON- N- CON- N- - crccccc ' QDU) NrNM 6a A N 1— N N N N N (n CI) fn N CO Cn N N N CO N CO Cn CO CO CI) N CO CO CO U CON C.) '- Z U c 0 - W - O O O O O O O O O O O O O O O O O O O O O O O o OQ U c tnnCO Cnn 001000000nOn00000000 cNeO m 6 C N N N O CD CD O CD CD CO CO CO CO CO N- CO CO 00 N N CO COCO ;D J o m E LL -1 NNNNNNNNNNN NN .-' NT J Cl) oLi .� c OO000 o L. C)N N N N O _ 0 m a 02222 ` E m I- CO Co CDN � tnInoOc- c- (OCOONN V) 0300NrQDC) T- u) Co 'E'. p C C C C C4- - C (Ni N M O r O tf') CC7 I- CD N N M M Cn O CA h oO 0) M CD O) M O) Q C tnCnC t N- CD1t10CDNNCoNMNMNNCDNt � �tN U in ,- CO) ' Co O oo 0 0 0 0 o v - - - a�i CJ o - C CL7 7 15 .7.,:i3 X X X X X X X X X X X X X X X X X X X X X X X X X E N•tn 0 2 LL LL LL LL LL LL LL LL W LL LL LL W LL LL LL LL LL LL LL LL LL LL LL LL o O » » » » > > >> > > > » » » » » '.°, t a V o _= o _o M X C O O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 O in 2 0 0 0 0 8 0 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CD © 0 M = 03 o mow.. tsmft .75 o � CV CV CV CV 0 0000 0000000000000000000000000 O N ' CD c)2 2 2 2 m +. E M /1 C CO CD I� CD CO CD C1� CD CO V' I� I� Cn Cn Cn CD CD V Cn '7 to CO ci a+ U 0 R - w L M rn R .0 .0 .0 .0 .0 Q •. 0 or N $_ = O7- N- MM N v0 m C • 0 1 � MO C.) CO O) O CD Co C) N- C CD O C) CD CD O N I,- N- CO N Co n N L 0O 0 -o co 000 • c) '1" 0 � C � 000) C00000C00N- 00N- 0NN � � � N � � rCO 6) N23 N CZ CU m- � W 0s 42 N 775 u- 6000000000000000000000000 � 8LQ o) CI- Oe L .4- 133 0 0 E *a tCL Oo O .1• - CV O >1 NLL C `' LCON CO CD V CO Co N crcr — CO CO CO N N 10 V CV crcrt co rt Cocr N cc co V^ _ coA. ma- CD _C Q. p)E N CO ) O) CD O O Cn r N- N O O CO Co y al Cn N Co T- MN T � � = 2w+ > - O Q. � y u 1� L U crs W N N - ^ v R O vco Yr 01 - CD cn o to v N wo 2Sz 0.)--g. MO CCD ' C0) CO N- CC)) C)) � CO0CntnCOn0MNCONN � � a 2 = r (9 5 2 3 T i' V a. U o CD V 7� (/) � 0_ > N '�t . 0CortCnCDCONCntn000Y• yr0ON. N- C COCON E o `�^+ (' I� r- L- � t) OCnCnO) MMO) COCONCONCDCOC) COl� � tn - o -I V u D o O 0 CD tt rtNO) O) COC) Cn CD M CO 00 CV -- U ,, Q 1iW s; v) Oj T- N '- NNMMNNN NN Co $ y m 0 0 �. ao W i D » — L U L 0 0 5 L 5 5 L 5 0 0 0 0 5 5 0 0 5 5 5 0 5 0 0 i o 4. r 3 a Cn o. N N I1 Y w .@ V) (6 7 . O .? Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st7 Peak AVF 394 365 0.073 501 12.0 0 x 0 ViniFlx st6 st6 Peak AVF 496 467 0.073 632 12.0 0 x 0 VinlFlx st2 st8 Peak AVF 269 197 0.095 610 9.0 0 x 0 ViniFlx st2 st3 Peak AVF 230 251 0.112 460 10.0 0 x 0 VinIFIx st1 st5 Peak AVF 187 196 0.088 444 9.0 0 x 0 VinlFlx st4 st4 Peak AVF 404 484 0.088 617 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 634 735 0.088 688 14.0 0 x 0 VinIFIx st2 Peak AVF 766 665 0.073 716 14.0 0 x 0 VinIFIx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb4 Ox 0 144 140 151.0 0.096 327 9.0 Ox 0 VIFx rt5 rb3 Ox 0 100 141 147.5 0.098 404 8.0 Ox 0 VIFx rt5 rb5 Ox 0 173 207 121.5 0.119 194 14.0 Ox 0 VIFx rt2 rsb3 Ox 0 766 665 142.6 0.102 548 16.0 Ox 0 VIFx rst2 rb2 Ox 0 218 247 199.0 0.073 454 10.0 Ox 0 VIFx rt5 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rstl Peak AVF 766 665 0.102 716 14.0 0 x 0 VinIFIx rst2 Peak AVF 766 665 0.102 716 14.0 0 x 0 VinIFIx rstl rt5 Peak AVF 462 528 0.073 378 16.0 0 x 0 VinIFIx rt2 rt2 Peak AVF 634 735 0.073 527 16.0 0 x 0 VinIFIx „ ' wrighYsoft 2018-Jul-2309:01:08 AC 's., ..�-_-�- Comfort Builder by Wrightsoft 18.0.20.01 RSU12270 Page 2 A ...Brothers\Franklin 3448 Left SW Lot 48 ABCC.rup Calc=MJ8 Front Door faces:SW