Loading...
730 JASMINE ST - ROOF r s� CITY OF ATLANTIC BEACH n 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 !) INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF18-0085 Description: shingle & modified bitumen re-roof Estimated Value: 12000 Issue Date: 8/10/2018 Expiration Date: 2/6/2019 PROPERTY ADDRESS: Address: 730 JASMINE ST RE Number: 170919 0500 PROPERTY OWNER: Name: GALLAGHER ROBERT CHRISTOPHER Address: 730 JASMINE ST ATLANTIC BEACH, FL 32233-1712 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: HAMMER TIME ROOFING Address: 13465 SOLEDAD CT DR JACKSONVILLE, FL 32204 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. OFFICE COPY RECEIVED ..,!....4„.,i; , c) = � BUILDING PERMIT APPLICATION v_, CITY OF ATLANTIC BEACH JUL 3 0 201 800 Seminole Road,Atlantic Beach FL 32233 -00 Fl OO ' °'''i,r Office: (904)247-5826 • Fax: (904)247-5845 Building Department City urAtlantic Book FL Job Address: 730 �AS ,; - e _A �- t Permit Number: e-DO Ft 1-00 KS— Legal Description/62-3 q3b'-aS-01-07I; Se c,F/ 4-14c-drtie,;, k RE# / 70 g/g •-0_�p[} (..0-Ti t 5 io4f Lao- 6 1 N(o Valuation of Work(Replacement Cost) $ /a, Our, Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s) (Circle one): Commercial Residen'' • If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No at• a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be erform d: (&_4vor 54 i-Air.-i vn lee- go(r.:4\ Florida Product Approval#_ I\f%11,- F I I 06114 T 2.S for multiple products use product approval form Property Owner Information �' g'+ - F L - 3 lei Name: h/-+� �,-(( Address: 73a -c.s,-, ,-,-Q S/. City p c..,A,_ j�,� 41 State K Zip 3 a a 7 3 Phone ��10 w 9'!j- i// ,3' E-Mail r r i-,.r; e_/Ic5 La.r( r- 'I (o.•L Owner or Agent 2f Agent,`Power of Ailey or Agency Letter Required) WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Contractor Information: // / /3e-/(p s S Name of Company: �f c,, Tom,_ jt -.�1 Qualifying Agent: On-/-A at tc.-,t atAr(- Address:/3 J 1-L (.4. City c by,,,,,'//e. State'Zip FL 3aaa - Office Phone 904 7/E - 9/4 1 Job Site/Contact Number VO(4) a yb -- a 3-5-4 State Certification/Registration# CCC/3 d q q y 3 E-Mail ha,„,.,e_/--i - P te,,e 0 6,„: 1.Ce . Architect Name &Phone# Engineer's Name & Phone# Worker's Compensation &, 7-6'ti xempt nsurer cf Employees / Expiration Date Application is hereby made to obtain a permit to do the work and installations as i dicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating c' ruction in t is . isdiction. T •s permit becomes null and void if work is not commenced within six(6) months, or if construction or work i• sus ended or,b,'honed for a riod o1six(6)months at any time after work is commenced. I understand that separate permits must be secur:%for lectrical i ,Plumbing, igns, Wells,Pools,Furnaces,Boilers,Heaters, Tan an Air Conditioners,etc. Signature of Property Owner:� / Signature of Contractor: —i Before me this a1 Day of U�� a-U u Before me this 30 Day of to O Notary Public: 410 l 11K`(tom' L_ (dc" Notary Public: `• ‘ . 1. .. .. ... ....- ,' rw ENNIFERJOHNSTON I hereby cent t,l lar,'rca:. , c4};rtr• t, ri,,s api ication and know the same to be tri . ,. • ;;111 gf. • v. i 081$841 ordinances g ,� t' , is rn he c nrt�ted with whether specified herein or not e.e, 'afttin . t presume to g +4.n ,, of federal, . • _. F _ $. �. n;.0-visions any other state, or IOC ;J,�...9atvr• `� J performance o,),: EXPIRES:June 12,2022 ..4'0,,,,o,r °R ii Bonded Thru Notary Public tlndx mkNe _.---- --- -- �„ ' 16 1) Ntr)TicE 017: COMB i NCE M E "� ipRE ARE.IN 0UFLUC.a. E Permit No. rP00F/� Es--dd gTax Folio No., / 7(4)�j/q ._(�S c State of / w,f--;do County of , )r4UG ' To whom it may concern: • The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following Information is stated in this NOTICE OF COMMENCEMENT. < U l-F I L E COPY Legal descr ipkon of property being improved: 1 d(� -3-4 .35. - as - a--c)/ r A. . At L 3 . io • + L(r1- 6 3ik 1146 Address of property being improved: ':3Q .,S(-)-1‘..-)e ,Si- . 4+icv` ¢,1 Ec -,J r(- 3 a a 2 3 General description of improvements: /` e ` PocDC O'..Tier 01)f,S fit ‘, (f r Odic; -t/‘ Address • _ • . �at •sr • _ 3 W `. • Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Q .J Z L � ULI LO Ci Name c. Address S wo Contractor ��v+ A. O a) E - ,?...i U o Address 3 - a ♦ C 1. .. �_ ❑ 0 ❑ . . Phone No. c.)(1.)?/‘- j 9F- Q Z /�/ Fax No. 0 Z o z Surety(if any) d Q Address Amount of bond S 1 - I-- I Phone No. Fax No. 0 Q 2 W raffle and address of any person making a loan for the construction of the improvements. Q O Lt. W j' flame >- 0. mm 3 �- W5 ❑ • Address W U U) W W Phone No. Fax No. > CC W 41 CC W • Name of person within the State of Florida.other than himself,desionated by owner upon whom notices or othercc •documents may be se Ned: Name Address Phone No. Fax No. In addition to himself,owner designates the foilo`.linc person to receive a copy of the Lienors Notice es provided in Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option). Name Address Phone i'lo. Fax No. • "•. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a ,A,�i' different date is specified): fl i, SPACE FOP.RECORDER'S USE ONLY/f7 'NER 7'eaA14 s l S:C eO: .. c�l DSI= 7/x7/1 ........... t _afce e e• '' c- \y t `-n t 8 intik_ reel-. �,,.._ il-slk: _ =cn ;y act=2ro i A Doc ?2018177913,OR BK.18473 Page X79, V ^A Tl t� sr�'r'r hf.rai-i i:y g"- i�lTSai`tutee?i and affirms that eii S:a. renis and deuaretans'n-iia Number Pages:1 l are;;ie an;.acturei_ Recorded 07/30/2018 08:52 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL / COUNTY /YV.1-, 201,1 RECORDING $10.00 ��s C' are G. Nc�iNotary r,..tgc"':ce.eta;=o; •-1i A.County of 1)U VAPity ccmmssia r ex-pima: '�i•U e . 9-0 LQ N reSo i Fer anally Known >< i -- Procucadi_entfication hr',rr r.0 i .tv\ i_Cs_e -. 2 TRINITY ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-6 1B Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 7 1e Wood ) Newi Reroof(Tear-Off)or Recover, . C Mech.Attached Insulation,Bonded Roof Cover 8-9 1D Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 10-12 1E-1 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 13-15 1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 16-17 1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 17 2A Steel or Structural Concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 18-20 2B Steel or Structural Concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 21-25 2C Steel or Structural Concrete New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 26-28 3A Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 29-36 3B Concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 36 3C Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 37 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 38-39 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 40 4C LWIC New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 41-44 5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 45 5B CWF New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 46 5C CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 46 5D CWF New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 47 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 48-49 6B Gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 50 6C Gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 51 6D Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 51 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 52-57 7B Various Recover F Non-Insulated,Bonded Roof Cover 57 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: OMG#14 Roofgrip with Flat Bottom Plate(Accutrac),OMG HD with OMG 3 in.Galvalume Steel Plate,Dekfast#14 with Hex Plate or 3"Round Insulation Plate,Trufast HD with Trufast 3" Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. > Steel Deck: OMG#12 or#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG#12 Standard or HD with OMG 3 in.Galvalume Steel Plate,Dekfast#12 or#14 with Hex Plate or 3"Round Insulation Plate,Trufast DP or HD with Trufast 3"Metal Insulation Plates or FlintFast#12 or#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: OMG#14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast#14 or DekSpike with Hex Plate or 3" Round Insulation Plate,Trufast HD or CF with Trufast 3"Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic®Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 1 of 57 TRINITY ERD 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite,GlasRoc Roof Board or gypsum-based roof board that meets the QA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for,or installed beneath rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover), whereby the base sheet screws and plates are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt(HA): Full coverage at 25-30 lbs/square ➢ Ashland Pliodeck(A-PD): Continuous 0.75 inch wide ribbons,12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below. > Dow INSTA-STIK Quik Set Insulation Adhesive(D-I5): Continuous 0.75 to 1 Inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. P. MI -in .11 • - • it r Grade Adhesive(M-PG1): Cont'n I • • • • • •• -• • • OMG 01 Bon 50n or Olv:..•Green OB500): Continuous 0.75-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot) ICP A hesives CR-20: on inuous .5 to -inc wi.e r... , . > Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,boards shall be staggered from layer-to-layer. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ Ashland Pliodeck(A-PD)@ 12-inch o.c. MDP -105.0 psf (Min.1.0-inch) ➢ Ashland Pliodeck(A-PD)@ 6-inch o.c. MDP -277.5 psf (Min.1.0-inch) ➢ Dow INSTA-STIK Quik Set Insulation Adhesive(D-IS): MDP -120.0 psf (Min.1.0-inch) ➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.1.0-inch) ➢ Millennium PG-1 Pump Grade Adhesive(M-PG1): MDP -157.5 psf (Min.1.0-inch) ➢ OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch Multi-Max FA3) ➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch ISO 95+GL) ➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch ENRGY 3) ➢ OMG OlyBond 500(0B500): MDP -487.5 psf (Min.0.5-inch ACFoam II) ➢ ICP Adhesives CR-2Q: MDP -117.5 psf (Min.1.0-inch) (� 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or par i ity-bvnded-inso n,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TA5 105. Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic'Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 2 of 57 TRINITY ERD 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Concrete Deck or Recover Applications using System Type D,the insulation is optional. 14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC Is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. CERTAINTEED FLINTLASTIC®MODIFIED BITUMEN COMPONENTS&APPLICATION METHODS Reference Layer Material Application BP AA Base Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20 Hot asphalt at 20-40 lbs/square (Base and Ply sheets,Asphalt-Appllad) Ply One or more Flintglas Ply 4;Flintglas Premium Ply 6 Base Yosemite Venting Base Hot asphalt in 24-inch diameter spots in 30- BP-AA2 inch grid pattern (Base,Spot-Asphalt-Applied) Base Yosemite Venting Base Hot asphalt in 9-inch diameter spots in grid BP-AA3 pattern noted herein. (Base,Spot-Asphalt-Applied) Base Yosemite Venting Base Hot asphalt In 9-inch wide ribbons spaced BP-AA4 as noted herein. (Base,Strip-Asphalt-Applied) BP-CA2 Base/Ply Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20 Henry#903 Adhesive at 1.5 gal/square Base/Ply Glasbase;All Weather/Empire Base;Flexiglas Base;Flintlastic Base 20 Millennium Hurricane Force Membrane BP CA3 Adhesive,beads spaced 6-inch o.c. Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Ply One or more Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base SBS-AA Cap Flintlastic Cap 30;Flintlastic Cap 30 CoolStar;Flintlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Hot asphalt at 20-40 lbs/square (SBS,Asphalt-Applied) Cap;Flintlastic FR-P;Flintlastic FR-P CoolStar;Flintlastic Premium FR-P;Flintlastic Premium FR-P CoolStar; Flintlastic GMS;Flintlastic GMS CoolStar Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. FlintBond Brush or Karnak No.81 Cold SBS-CAIProcess Modified Bitumen Adhesive Brush Ply Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Grade at 1 gal/square (SBS,Cold-Applied) Cap Flintlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Cap;Flintlastic FR-P;Flintlastic FR-P CoolStar; Flintlastic Premium FR-P;Flintlastic Premium FR-P CoolStar;Flintlastic GMS;Flintlastic GMS CoolStar Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Ply Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base SBS CA2 Cap Flintlastic Cap 30;Flintlastic Cap 30 CoolStar;Flintlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Henry#903 Adhesive at 1.5 gal/square. (SBS,Cold-Applied) Cap;Flintlastic FR-P;Flintlastic FR-P CoolStar;Flintlastic Premium FR-P;Flintlastic Premium FR-P CoolStar; Flintlastic GMS;Flintlastic GMS CoolStar Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificatexterioa Research and Design,LLC.d/b/a TrinitylERD 61"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 of Authorization#9503pp A endix 1,Pag e 3 of 57 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastice Modified Bitumen Roof Systems;(610)651-5847 TRINITY ERD CERTAINTEED FLINTLASTIC.MODIFIED BITUMEN COMPONENTS&APPLICATION METHODS(CONTINUED) Reference Layer Material Application Base Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base Ply Flintlastic Base 20;Flintlastic Poly SMS Base;Flintlastic Ultra Poly SMS Base SBS-CA3 Millennium Hurricane Force Membrane (SBS,Cold-Applied) Cap Flintlastic Cap 30;Flintlastic Cap 30 CoolStar;Flintlastic FR Cap 30;Flintlastic FR Cap 30 CoolStar;Flintlastic FR Dual Adhesive,beads spaced 6-Inch o.c. Cap;Flintlastic FR-P;Flintlastic FR-P CoolStar;Flintlastic Premium FR-P;Flintlastic Premium FR-P CoolStar; Flintlastic GMS;Flintlastic GMS CoolStar Base Flintlastic Ultra Poly SMS Base;Flintlastic Base 20 T SBS-TA Ply One or more Flintlastic Ultra Poly SMS Base;Flintlastic Base 20 T Torch-Applied (SBS,Torch-Applied) Cap Flintlastic FR Cap 30 T;Flintlastic FR Cap 30 T CoolStar;Flintlastic GTS;Flintlastic GTS CoolStar;Flintlastic GTS-FR; Flintlastic GTS-FR CoolStar;FlintClad Base One or more Flintlastic APP Base T;Flintlastic STA;Flintlastic STA Plus APP-TA Cap Flintlastic STA;Flintlastic STA Plus;Flintlastic GTA;Flintlastic GTA CoolStar;Flintlastic GTA-FR;Flintlastic GTA-FR Torch-Applied (APP,Torch-Applied) CoolStar SBS-SA-H Base/Ply Black Diamond Base Sheet;Flintlastic Ultra Glass SA Self-Adhering (SBS,Self-Adhering,Hybrid Systems) Base Flintlastic SA PlyBase;Flintlastic SA Mid Ply SBS-SA Ply Flintlastic SA PlyBase;Flintlastic SA Mid Ply Self-Adhering (5B5,Self-Adhering) Cap Flintlastic SA Cap;Flintlastic SA Cap CoolStar;Flintlastic SA Cap FR;Flintlastic SA Cap FR CoolStar 16. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design,LLC.d/b/a TrinitylERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization#9503 6Th EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic*Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 4 of 57 TRINITY ERD TABLE 1A: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Sys. Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) MOP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psi) SELF-ADHERING SYSTEMS: Glasbase,All Min.19/32- 32 ga.,1-5/8- 9-inch o.c.in 4-inch Min.1.5-inch Min.0.25-inch Weather Empire, inch inch dia.tin lap and 12-inch o.c. ACFoam II, Dens Deck (Optional) W-1 plywood at Flexiglas Base, caps with 11 ga. in two(2),equally FlintBoard ISO, HA primed with HA SBS-SA SBS-SA -45.0` max.24- Flintlastic Base 20; SBS-SA annular ring spaced,staggered ENRGY-3,H-Shield FlintPrime or inch spans Poly SMS;Ultra Poly shank nails center rows or Multi-Max FA3 FlintPrime SA SMS;Yosemite HA full HA full Min.19/32- Glasbase,All 32 ga.,1-5/8- 8-Inch o.c.in 3-inch Min.1.5-inch Min.0.25-inch coverage or coverage or inch Weather Empire, inch dia.tin lap and 8-inch o.c. ACFoam II, Dens Deck 0B500,M- OB500,M- (Optional) W-2 plywood at Flexiglas Base,Poly caps with 11 ga. in three(3),equally FlintBoard ISO, primed with SBS-SA SBS-SA -52.5 OSFA,A-PD, OSFA,A-PD,D- SBS-SA max.24- SMS or Ultra Poly annular ring spaced,staggered ENRGY-3,H-Shield FlintPrime or Inch spans SMS shank nails center rows or Multi-Max FA3 D-IS or CR-20, FlintPrime SA IS or CR-20,6 4-inch o.c. inch o.c. Min.19/32- 32 ga.,1-5/8- 8-Inch o.c.in 3-Inch Min.1.5-inch Min.0.25-inch inch inch dia.tin lap and 8-inch o.c. ACFoam II, Dens Deck W-3 plywood at Yosemite Venting (Optional)caps with 11 ga. in three(3),equally FlintBoard ISO, HA primed with HA SBS-SA SBS-SA -52.5 max.24- Base Sheet SBS-SA annular ring spaced,staggered ENRGY-3,H-Shield FlintPrime or inch spans shank nails _center rows or Multi-Max FA3 FlintPrime SA HA full Min.0.25-inch HA full Min.19/32- Glasbase,All 32 ga.,1-5/8- 8-inch o.c.in 3-inch (Optional)Min. SECUROCK coverage or coverage or inch Weather Empire, inch dia.tin lap and 8-inch o.c. 1.5-inch ACFoam Gypsum-Fiber OB500,M- 08500,M- (Optional) W-4 plywood at Flexiglas Base,Poly caps with 11 ga. in three(3),equally II,FlintBoard ISO, Roof Board SBS-SA SBS-SA -60.0 max.24- SMS or Ultra Poly annular ring spaced,staggered ENRGY-3,H-Shield OSFA,A-PD, primed with OSFA,A-PD,D- SBS SA inch spans SMS shank nails center rows or Multi-Max FA3 DIS or CR-20, FlintPrime or IS or CR-20,6- 4-inch o.c. Inch o.c. FlintPrime SA Min.0.25-Inch Min.19/32- 32 ga.,1-5/8- 8-inch o.c.in 3-inch (Optional)Min. SECUROCK inch inch dia.tin lap and 8-inch o.c. 1.5-inch ACFoam Gypsum-Fiber W-5 plywood at Yosemite Venting caps with 11 ga. in three(3),equally II,FlintBoard ISO, HA Roof Board HA SBS-SA (Optional) SBS-SA -60.0 Base Sheet SBS-SA max.24- annular ring spaced,staggered ENRGY-3,H-Shield primed with Inch spans shank nails center rows or Multi-Max FA3 FlintPrime or FlintPrime SA HYBRID SYSTEMS: Glasbase,All Min.19/32- Weather Empire, 32 ga.,1-5/8- 9-inch o.c.in 4-Inch Min.1.5-inch inch inch dia.tin lap and 12-inch o.c. ACFoam II, (Optional) SBS-AA, Flexiglas Base, BP-AA,SBS- SBS-TA W-6 plywood at Flintlastic Base 20; caps with 11 ga. in two(2),equally FlintBoard ISO, HA None N/A SBS-SA-H AA,SBS-TA or APP- -45.0* max.24- Poly SMS;Ultra Poly annular ring spaced,staggered ENRGY-3,H-Shield inch spans shank nails center rows or Multi-Max FA3 or APP-TA TA SMS;Yosemite Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic'Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 5 of 57 TRINITY ERD TABLE 1A: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Sys. Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf) Min.19/32- 32 ga.,1-5/8- 8-inch o.c.in 3-inch Min.1.5-inch (Optional) SBS-AA, inch Glasbase;Flintglas inch dia.tin lap and 8-inch o.c. ACFoam II, BP-AA,SBS- SBS-TA W-7 plywood at Premium Ply 6; caps with 11 ga. in three(3),equally FlintBoard ISO, HA None N/A SBS-SA-H AA,SBS TA or APP- max. -60.0 24- Yosemite annular ring spaced,staggered ENRGY-3,H-Shield or APP-TA TA inch shank nails center rows or Multi-Max FA3 CONVENTIONAL SYSTEMS: Min.19/32- Glasbase,All 32 ga.,1-5/8- 9-inch o.c.in 4-inch Min.1.5-inch Min.0.25-inch inch Weather Empire, inch dia.tin lap and 12-Inch o.c. ACFoam II, Dens Deck BP-AA, (Optional) SBS-AA, Plexiglas Base , SBS-AA, BP-M,SBS- SBS-TA 45.0* W-8 plywood at caps with 11 ga. in two(2),equally FlintBoard ISO, HA primed with HA SBS-TA or AA,SBS TA or APP- max.24- Flintlastic Base 20; annular ring spaced,staggered ENRGY-3,H-Shield FlintPrime(ASTM Poly SMS;Ultra PolyAPP-TA or APP-TA TA inch spans SMS;Yosemite shank nails center rows or Multi-Max FA3 D41)primer HA full HA full Min.19/32- Glasbase,All 32 ga.,1-5/8- 8-Inch o.c.in 3-inch Min.1.5-inch coverage or Min.0.25-inch coverage or BP-AA, (Optional) SBS-AA, inch Weather Empire, inch dia.tin lap and 8-inch o.c. ACFoam II, Dens Deck OB500,M- OB500,M- SBS-AA, BP-AA,SBS- SBS-TA -52.5 W-9 plywood at Plexiglas Base,Poly caps with 11 ga. in three(3),equally FlintBoard ISO, primed with OSFA,A-PD, OSFA,A-PD,D- SBS-TA or AA,SBS-TA or APP- max.24- SMS or Ultra Poly annular ring spaced,staggered ENRGY-3,H-Shield D-IS or CR-20, FlintPrime(ASTM IS or CR-20,6- APP-TA or APP TA TA inch spans SMS shank nails center rows or Multi-Max FA3 4-inch o.c. D41)primer inch o.c. Min.19/32- 32 ga.,1-5/8- 8-inch o.c.in 3-inch Min.1.5-inch Min.0.25-inch BP-AA, (Optional) SBS AA, inch inch dia.tin lap and 8-inch o.c. ACFoam II, Dens Deck SBS-AA, BP-AA,SBS- SBS TA Yosemite Venting52.5 W-10 plywood at caps with 11 ga. in three(3),equally FlintBoard ISO, HA primed with HA SBS-TA or AA,SBS TA or APP- max.24- Base Sheet annular ring spaced,staggered ENRGY-3,H-Shield FlintPrime(ASTM APP-TA or APP-TA TA inch spans shank nails center rows or Multi-Max FA3 D41)primer HA full HA full Min.19/32- Glasbase,All 32 ga.,1-5/8- 8-Inch o.c.In 3-inch (Optional)Min. coverage or Min.0.25 inch coverage or BP-AA, (Optional) SBS-AA, inch Weather Empire, inch dia.tin lap and 8-inch o.c. 1.5-inch ACFoam OBS00,M- SECUROCK 013500,M- SBS-AA, BP-AA,SBS- SBS TA W-11 plywood at Flexiglas Base,Poly caps with 11 ga. in three(3),equally II,FlintBoard ISO, OSFA,A-PD, Gypsum-Fiber OSFA,A-PD,D- SBS-TA or AA,SBS-TA or APP- max. -60.0 max.24- SMS or Ultra Poly annular ring spaced,staggered ENRGY-3,H-Shield D-IS or CR-20, Roof Board IS or CR-20,6- APP-TA or APP-TA TA inch spans SMS shank nails center rows or Multi-Max FA3 4-inch o.c. inch o.c. Min.19/32- 32 ga.,1-5/8- 8-inch o.c.In 3-inch (Optional)Min. Min.0.25 inch BP-AA, (Optional) SBS AA, inch inch dia.tin lap and 8-inch o.c. 1.5-inch ACFoam SECUROCK 585 AA, BP-AA,SBS- SBS-TA Yosemite Venting caps with 11ga. in three(3),equally II,FlintBoard ISO, HA HA -60.0 W 12 plywood at P q y Gypsum-Fiber SBS-TA or AA,SBS-TA or APP- max.24- Base Sheet annular ring spaced,staggered ENRGY-3,H-Shield Roof Board APP-TA or APP-TA TA inch spans shank nails center rows or Multi-Max FA3 Exterior Research and Design,LIC.d/b/a Trinity(ERD Evaluation Report 3520.03.04-R20 for FL2533-R19 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic•Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 6 of 57 TRINITY ERD TABLE 1B: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP(psf) No. (Note 1) Type _ Fasteners Attach Type Attach Base Ply Cap HYBRID SYSTEMS: Min.15/32-Inch Min.1.5-inch ACFoam FlintFast#12 or Min.1.5-Inch ACFoam II, HA,D-15,M- exterior grade II,FlintBoard ISO,H- #14 with 1 per 1.33 FlintBoard ISO,H-Shield or OSFA,M-PG1 SBS-SA-H (Optional)APP-TA APP-TA -67.5 W-13 plywood at max.24- Shield or FlintBoard FlintFast 3" ft2or OB500 FlintBoard'SOH. inch spans ISOH. Insulation Plates CONVENTIONAL SYSTEMS: Min.0.5-inch Structodek Min.23/32-inch Min.1.5-inch ACFoam High Density Fiberboard BP AA or (Optional)BP-AA, 585-AA,SBS- W-14exterior grade SBS-AA,SBS-TA or -45.0* II,FlintBoard ISO, Note 2 1 per 2 ft2 Roof Insulation,min.0.75 HA SBS-AA TA or APP-TA plywood at max.24- ENRGY 3,H-Shield inch FescoBoard APP-TA inch spans (homogeneous) Min.23/32-inch Min.0.25-inch SECUROCK BP-AA,SBS- (Optional)BP-AA, Min.1.5-Inch ACFoam 2 Gypsum-Fiber Roof Board, SBS-AA,SBS- 45.0* exterior grade II,FlintBoard ISO, Note 2 1 per 2 ft HA AA,SBS-TA SBS-AA,SBS-TA or TA or APP-TA W-15 plywood at max.24- Dens Deck or Dens Deck or APP-TA APP-TA ENRGY 3,H-Shield or inch spans . Min.15/32-inch Min.1.5-inch ACFoam FlintFast#12 or Optional additional layer(s) HA,D-IS,M exterior grade II,FlintBoard ISO,H- #14 with 1 per 1.33 of base insulation followed OSFA,M-PG1 APP-TA (Optional)APP-TA APP-TA -90.0 W-16 plywood at max.24- Shield or FlintBoard FlintFast 3" ft2 by Min.0.25-inch SECUROCK or 08500 inch spans ISO,,. Insulation Plates Gypsum-Fiber Roof board Evaluation Report 3520.03.04-R20 for FL2533-R19 Exterior Research and Design,LLC.d/b/a Trinity)ERD 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 Certificate of Authorization#9503 Appendix 1,Page 7 of 57 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic6 Modified Bitumen Roof Systems;(610)651-5847 TRINITY ERD TABLE 1C: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Top Insulation Layer Roof Cover(Note 14) MDP Base Insulation Layer No. (Note 1) Type Fasteners Attach Base Ply Cap (Psf) SELF-ADHERING SYSTEMS: / Flintfast 3 in.Insulation (Optional)SBS- Min.15/32-inch (Optional)One or more Min.0.25-inch SECUROCK 585 SA 30.0' W-17 plywood at max.24- layers,any combination, Plates with FlintFast#12 1 per 3.2 ft2 SBS-SA SA Gypsum-Fiber Roof Board or#14 inch spans loose laid Apply FlintPrime or Min.19/32-inch (Optional)One or more 2 FlintPrime SA to (Optional)SBS- W-18 exterior grade plywood layers,any combination, Min.0.25-inch Dens Deck Note 2 1 per 1.33 ft board&plates, 5q SBS-SA -45.0 at max.24-inch spans loose laid followed by SBS-SA Min.19/32-Inch (Optional)One or more Flintfast 3 in.Insulation (Optional)SBS- Min.3/8Inch SECUROCK Plates with FlintFast#12 1per 2.7 ft2 SBS-SA SBS-SA -45.0' W-19 exterior grade plywood layers,any combination, Gypsum-Fiber Roof Board SA at max.24-inch spans loose laid or#14 Min.19/32 inch (Optional)One or more Min.1.5 Inch ACFoam II, Flintfast 3 in.Insulation Apply FlintPrime or2 FlintPrime SA to (Optional)SBS- W-20 plywood at max.24- layers,any combination, ENRGY 3,H-Shield,Multi-Max Plates with FlintFast#12 1 per 2 k board&plates, SA SBS-SA -45.0` inch spans loose laid FA3 or FllntBoard ISO or#14 followed by SBS-SA FlintFast#14 HD with Min.15/32-inch (Optional)One or more FlintFast 3"Insulation Apply FlintPrime to (Optional)SBS- W-21 plywood at max.24- layers,any combination, Min.1.5-inch FlintBoard ISO Plates or Trufast HD 1 per 1.6 ft2 board&plates, SA SBS-SA -52.5 inch spans loose laid with Trufast 3"Metal followed by S8S-SA Insulation Plates Apply FlintPrime or Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, ft2 FlintPrime SA to (Optional)SBS- W-22 plywood at max.24- layers,any combination, ENRGY 3,H-Shield,Multi-Max Note 2 1 per 1.45 board&plates, SA SBS-SA -60.0 inch spans loose laid FA3 or FlintBoard ISO followed by SBS-SA HYBRID SYSTEMS: Min.15/32-inch (Optional)One or more Flintfast 3 in.Insulation (Optional)BP- SBS-AA,SBS-TA Min.0.25-inch Dens Deck; Plates with FlintFast#12 1per 2 ft2 SBS-SA-H AA,SBS-AA,SBS- -30.0• W-23 plywood at max.24- layers,any combination, Dens Deck Prime or APP-TA inch spans loose laid or#14 TA or APP-TA FlintFast#14 HD with Min.15/32-inch (Optional)One or more FlintFast 3"Insulation (Optional)SBS- SBS-TA or APP- W-24 plywood at max.24- layers,any combination, Min.1.5-inch FlintBoard ISO Plates or Trufast HD 1 per 1.6 ft2 SBS-SA-H TA or APP-TA TA -52.5 Inch spans loose laid with Trufast 3"Metal Insulation Plates Min.15/32-inch (Optional)One or more Min.1.5-inch ACFoam II, (Optional)BP-AA W-25 plywood at max.24- layers,any combination, FlintBoard ISO,ENRGY 3 or Note 2 1 per 1.33 ft2 SBS-SA-H or SBS-AA SBS-AA -52.5 inch spans loose laid Multi-Max FA3 Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, (Optional)BP- SBS-AA,SBS-TA W-26 plywood at max.24- layers,any combination, FlintBoard ISO,H-Shield, Note 2 1 per 1.45 ft2 SBS-SA-H AA,SBS-AA,SBS- or APP-TA -60.0 inch spans loose laid FlintBoard ISO„ TA or APP-TA Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report 3520.03.04-R20 for FLZ533-R19 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic•Modified Bitumen Roof Systems;(610)651-5847 Appendix 1,Page 8 of 57 • TRINITY ERD TABLE 1D: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPED: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER Deck Insulation Layer(s) Base or Anchor Sheet Roof Cover(Note 14) MDP System No. (Note 1) I Type I Attach I Base I Fasteners I Attach I Ply I Cap (Psf) SELF-ADHERING SYSTEMS: 8-inch o.c.at min.3-inch lap and fl- inch o.c.in two(2),equally spaced, (Optional) Min.19/32-inch Min.1.5 inch,One Prelim. sta ered center rows;Stress plates 585 SA 82.5• W_34 plywood at max 24- or more layers, Attach Flintlastic SA NailBase Note 2 gB SBS-SA shall be primed with FlintPrime Inch spans any combination (ASTM D41)primer or FlintPrime SA Flintfast 3 in.Insulation Plates 6-inch o.c.at min.2-inch lap and 6- with FlintFast#12 or#14; inch o.c.in three(3),equally spaced, Min.15/32-inch Min.1.5 inch,One Prelim. Trufast 3"Metal Insulation (Optional) SBS SA 97.5` Flintlastic SA NailBase staggered center rows; Stress platesMG SBS SA W-35 plywood at max 24- or more layers, Attach Plates with DP or HD;O 3 shall be primed with FlintPrime inch spans any combination in.Round Metal Plates with (ASTM D41)primer or FlintPrime SA. OMG#14 HD Flintfast 3 in.Insulation Plates 6-inch o.c.at min.2-inch lap and 6- with FllntFast#12 or#14; inch o.c.In four(4),equally spaced, Min.15/32 inch Min.1.5-inch,One Prelim. Trufast 3"Metal Insulation (Optional) SBS SA 127.5` Flintlastic SA NailBase staggered center rows; Stress platesOMG SBS-SA W-36 plywood at max 24- or more layers, Attach Plates with OP or HD; 3 shall be primed with FlintPrime inch spans any combination in.Round Metal Plates with (ASTM D41)primer or FlintPrime SA. OMG#14 HD HYBRID SYSTEMS: Flintfast 3 in.Insulation Plates 6-inch o.c.at 4-inch lap and 6-inch with FlintFast#12 or#14; o.c.in three(3),equally spaced, Min.15/32 inch Min.1.5-inch,One Prelim. Glasbase;Flexiglas; Trufast 3"Metal InsulationSBS-AA,SBS- -97.5 wood at max 24- or more layers, Flintlastic Base 20;Poly SMS staggered center rows; Stress plates SBS-SA-H TA or APP-TA Inch spans any combination Base;Ultra Poly SMS Base W-37 ply Attach Plates with DP or HD;OMG 3 shall be primed with FlintPrime in.Round Metal Plates with (ASTM D41)primer or FlintPrime SA. OMG#14 HD Glasbase;Flexiglas; 7-inch o.c.at 3-inch lap and 7-inch SBS-AA,SBS- Min.19/32-inch Min.1.5-inch,One Prelim. g o.c.in three(3),equally spaced, SBS-SA-H 105.0 W-38 plywood at max 24- or more layers, Attach Flintlastic Base 20;Poly SMS Note 2 TA or APP-TA inch spans any combination Base;Ultra Poly SMS Base staggered center rows P Flintfast 3 in.Insulation Plates 6-inch o.c.at 4-inch lap and 6-inch with FlintFast#12 or#14; o,c,in four(4),equally spaced, Min.15/32-inch Min.1.5 inch,One Prelim. Glasbase;Flexiglas; Trufast 3"Metal Insulation SOS- 127.5 W-39 plywood at max 24- or more layers, Flintlastic Base 20;Poly SMS staggered center rows;Stress plates SBS-SA-H TA or APP-TA Attach Plates with DP or HD;OMG 3 shall be primed with FlintPrime inch spans any combination Base;Ultra Poly SMS Base in.Round Metal Plates with (ASTM D41)primer or FlintPrime SA. OMG#14 HD CONVENTIONAL SYSTEMS: Evaluation Report 3520.03.04-R20 for FL2533-R19 Exterior Research and Design,LLC.d/b/a Trinity IERD 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/14/2017 Certificate of Authorization#9503 Appendix 1,Page 10 of 57 Prepared by: Robert Nieminen,PE-59166 CertainTeed Flintlastic•Modified Bitumen Roof Systems;(610)651-5847